Technical Specification  
Digital Pressure Switch  
ISE30-# Series  
ZSE30-# Series  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety  
The Digital Pressure Switch and this technical specification essential information for the protection  
of users and others from possible injury and damage to property and to ensure correct handling.  
Please check that you fully understand the definition of the following messages (signs) before  
going on to read the text, and always follow the instructions.  
Also read carefully the technical specification of relevant equipment or apparatus before use.  
Indications  
IMPORTANT MESSAGES  
Read this manual and follow its instructions. Signal words such as WARNING, CAUTION  
and NOTE, will be followed by important safety information that must be carefully reviewed.  
Indicates a potentially hazardous situation which could result in death  
or serious injury if you do not follow instructions.  
Indicates a potentially hazardous situation which if not avoided, may  
result in minor injury or moderate injury.  
Gives you helpful information.  
NOTE  
Usage Restrictions  
This product is designed for use in general equipment for factory automation. Never use this  
product with equipment or apparatus that directly concerns human lives*1, or which  
malfunction or failure can cause a huge loss.  
*1: Equipment or apparatus that directly matters human lives means the following:  
Medical equipment such as life support systems or equipment used in operating rooms  
Compulsory equipment required by law such as the Fire Prevention Law, Construction Law  
and etc.  
Equipment or apparatus that conforms with those mentioned above.  
Contact our sales department when plans are made for the product to be used for the system*2  
including equipment that concerns itself with the safety of persons or that seriously affects the  
public. This usage needs special consideration*3.  
*2: The system including equipment that concerns itself with the safety of persons or that seriously  
affects the public means the following:  
Nuclear reactor control systems in nuclear power plants, safety protection systems or other  
systems important for safety in nuclear power facilities  
Driving control systems of mass transportation systems, and flight control systems  
Equipment or apparatus that comes into contact with foods or beverages  
*3: Special consideration means discussing usage with our engineers to establish a safe system  
designed as fool-proof, fail-safe, redundant and etc.  
Special consideration of safety or maintainability should be taken to prevent hazard or loss  
caused by a failure or malfunction that is likely to occur in certain probability due to  
environmental stress (deterioration).  
The special consideration means to fully review the equipment or apparatus in design stage  
and to establish a backup system in advance such as a redundant system or fail-safe system.  
Use for an interlocking circuit  
When using the pressure switch as a sensor for interlock, adopt a double interlocking method  
such as equipping the mechanical protection function in order to deal with a pressure switch  
failure.  
Check the pressure switch regularly to ensure proper operation.  
-2-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operator  
This technical specification has been written for those who have knowledge of machinery and  
apparatus that use pneumatic equipment and have full knowledge of assembly, operation and  
maintenance of such equipment.  
Please read this technical specification carefully and understand it before assembling, operating  
or providing maintenance to the pressure switch.  
Safety  
Do not disassemble, modify (including change of printed circuit board) or repair.  
An injury or failure can result.  
Do not operate the pressure switch beyond specification range.  
Do not use the pressure switch for inflammable or harmful gas or fluid.  
Operation at a range that exceeds the specifications can cause a fire, malfunction, or damage to  
the pressure switch.  
Verify the specifications before use.  
Do not use the pressure switch in an atmosphere containing combustible or explosive gas.  
A fire or explosion can result.  
This pressure switch is not an explosion-proof type.  
These instructions must be followed when using the pressure switch in an interlocking circuit:  
Provide double interlocking by another system such as mechanical protection.  
Check the pressure switch regularly to ensure proper operation.  
Otherwise malfunction can cause an accident.  
These instructions must be followed while in maintenance:  
Turn off the power supply.  
Stop the supplied air, exhaust the residual pressure and verify the release of air before  
performing maintenance.  
Otherwise it can cause injury.  
Don’t use this product near by a place where static electricity is a problem.  
Otherwise it can cause failure or malfunction of a system.  
Perform proper functional checks and leak tests after maintenance.  
Stop operation when an abnormality is observed such that the pressure switch does not work  
properly or there is a leakage of fluid.  
Safety is not be assured due to unexpected malfunction.  
-3-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE  
Follow the instruction given below when designing, selection and handling your pressure switch.  
The instructions on design and selection.  
Installation, wiring, environment of use, adjustment, operation and maintenance described below  
must also be followed.  
Product specifications  
This product designed only for the measurement of pressurized air (including vacuums).  
The pressurized air must contain no chemicals, synthetic oil with organic solvent, salts nor corrosive  
gas.  
Air that includes these substances can cause damage or malfunction of the digital pressure switch.  
Verify the specifications in detail before use.  
Do not use the product for pressurized air containing plenty of condensed water.  
Otherwise it can cause malfunction of the pressure switch.  
When measuring the air with condensed water, install an air-dryer / drain catch before filter, and  
release the condensed water regularly.  
Improper draining of condensed water can result in the flow out of condensed water into the  
secondary piping causing malfunction of pneumatic devices.  
Use of the filter with an automatic draining function is recommended when the draining is difficult to  
perform.  
Refer to our manual “Pressurized Air Purifying System” for details of the quality of the pressurized air.  
Operate the pressure switch with the specified voltage.  
Operation with a voltage beyond specifications can cause malfunction or damage of the pressure  
switch.  
Insufficient supply voltage may not drive a load due to a voltage drop inside the pressure switch.  
Verify the operating voltage of the load before use.  
Use the pressure switch within the specified ranges of the measurement flow rate and under the  
specified operating pressure.  
Otherwise it can cause damage to the pressure switch and an abnormal measurement.  
Do not apply constant pressure higher than 0.5MPa to vacuum pressure switch. (Specifications : -101  
to 101kPa)  
Do not exceed the specified maximum allowable load.  
Otherwise it can cause damage or shorten the lifetime of the pressure switch.  
Input data to pressure switch is not erased after power is off.  
(Rewriting times: 100,000 times, Data duration: 10 years after power off.)  
Reserve a space for maintenance.  
Remember to leave space for maintenance when designing the piping plan.  
This pressure switch is recognized  
marking only if the body initialized  
marking.  
Product handling  
Installation  
Do no drop, hit or apply excessive shock (100 m/s2) to the pressure switch.  
Otherwise it can result in damage to the pressure switch causing failure or malfunction.  
Do not pull lead wires or lift the body with lead wires. (Tensile strength is less than 35N)  
Hold the body when handing.  
Otherwise it can result in damage of the pressure switch causing failure or malfunction.  
Follow the specified tightening torque  
Excessive tightening torque can break the pressure switch, bracket, and mounting screws.  
Insufficient tightening torque can displace the pressure switch from the original position or loosen the  
mounting screws.  
When piping, apply the wrench only to the metal portion (attachment to be piped) integrated into the  
piping.  
Applying the wrench in other position can break the pressure switch.  
-4-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Blow off all the dust inside the pipes before piping the pressure switch.  
Otherwise it can cause damage or malfunction.  
Clean the inside of the pipe of dust or tape sealant when screwing pipes or joints.  
When using tape sealant, leave a couple of screw threads unwrapped with tape sealant.  
Otherwise it can cause damage or malfunction.  
Do not apply excessive external force with joints such as hoses when installing with a panel  
mount adapter.  
Otherwise it can damage the pipe joint of the pressure switch or cause drop off from the panel  
mount adapter.  
Do not insert wires or other foreign matter into the pressure measurement port.  
It can damage the pressure sensor causing failure or malfunction.  
Connect frame-ground terminal (FG terminal) to the ground when using a switching power supply.  
Insert a noise filter (power line noise filter, ferrite core, etc.) between the switching power supply  
and this pressure switch when using analog output.  
Do not apply unnecessary forces such as twisting, pulling, moment loads, etc. on fittings or  
tubing.  
When using a brand of tubing other than SMC, be careful of the tolerance of the tube’s O.D.  
1) Nylon tube ≤±0.1mm  
2) Soft nylon tube ≤±0.1mm  
3) Polyurethane tube +0.15mm, -0.2mm  
This pressure sensor is for air only.  
Please contact with SMC if you need to use other fluid.  
Wiring  
Do not bend or apply tensile stress to lead wires repeatedly.  
Wiring with repetitive bending stress or tensile stress can cause breakage of the lead wires.  
Replace the product when damage to a lead wire is observed.  
Connect wires and cables correctly.  
Miswiring can break the pressure switch depending on a miswired circuit.  
Do not connect wires while the power is on.  
Otherwise it can break the circuit inside the pressure switch causing malfunction.  
Do not lay wires or cables with power cable or high-voltage cable in the same wiring route.  
Otherwise the wires to the pressure switch can be contaminated with noise or induced surge  
voltage from power lines or high voltage lines causing malfunction.  
Lay the wires to the pressure switch to a wire duct or in a protective tube other than those for  
power lines or high voltage lines.  
Verify the insulation of wiring.  
Poor insulation (interference with other circuit, poor insulation between terminals and etc.) can  
introduce excess voltage or current to the pressure switch causing damage.  
Keep wiring as short as possible to prevent contamination from noise and induced surge voltage.  
Do not use a cable longer than 10m. Consult with SMC for the use with a cable longer than 10 m.  
Connect the 0V DC wire (blue line) directly or as close as possible to the 0V DC terminal of the  
DC power supply.  
The direct-current power supply to combine should use UL authorization power supply which is  
the class 2 power supply based on UL 1310 or the power supply is using the transformer of a  
class 2 based on UL 1585.  
Environment  
Do not use the product in an atmosphere containing corrosive gas, chemicals, sea water, water  
or vapor, or in a place where there is a possibility of adhesion of those substances to the product.  
It can cause failure or malfunction.  
Avoid exposure of this product to direct sunlight.  
Use sunshades if the product is exposed to direct sunlight.  
Otherwise it can cause failure or malfunction.  
Do not use in a place where water, oil or chemicals splashes.  
Otherwise it can cause failure or malfunction.  
-5-  
PS##-OMF0010-B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Do not use a pressure switch nearby a place where electric surges are generated.  
Internal circuit elements of the pressure switch can deteriorate or break when equipment generating  
a large surge (electromagnetic lifter, high frequency induction furnace, motor, etc.) is located near  
the pressure switch. Provide surge preventives, and avoid interference.  
Do not apply the pressure switch to the load that generates electric surge voltage.  
Relays or solenoid values generate electric surge voltage. When applying the pressure switch to  
drive these loads directly, use the product equipped with surge absorber.  
The product is not resistive to a lightning surge defined in CE marking. Take measures to protect  
against a lightning surge at the load side.  
Prevent foreign matter such as remnant of wires from entering this product.  
Take proper measures for the remnant not to enter the pressure switch in order to prevent failure or  
malfunction.  
Do not expose the pressure switch to vibration (less than 98 m/s2), and impact (less than 100 m/s2)  
Otherwise it can cause damage or malfunction.  
Follow the specified ranges of the operating fluid and maintain ambient temperatures.  
The operating fluid and ambient temperatures should be in the range of 0 to 50 °C.  
When operating at low temperature of 5°C or below, breakage or malfunction can occur to the  
pressure switch due to freezing of condensed water in the pressurized air.  
Take preventive measures against freezing. Installation of an air dryer is recommended in order to  
remove condensed water contained in the measuring fluid.  
Do not use the pressure switch in a place where temperature suddenly changes even if it stays  
within the specified range.  
Do not expose the pressure switch to heat radiation from a heat source located nearby.  
It can cause malfunction.  
Adjustment and Operation  
Do not short-circuit the load.  
The pressure switch indicates the error status when a load is short-circuited. However, excess  
current can damage the pressure switch.  
Do not press the buttons with a sharp object.  
It can cause damage to the setting buttons.  
A warm-up time of 20 to 30 minutes is needed for detection of low pressure.  
The indication drifts about ±1% soon after the power is on.  
Do not touch the LCD during operation.  
The indication on the LCD changes due to static electricity.  
Maintenance  
Before performing maintenance, make sure to turn off the power supply, stop supplied air, release  
the residual air in the piping into the atmosphere, and verify that the pneumatic system is open to  
the air.  
Otherwise an unexpected operation of the system component can occur.  
Perform maintenance and check regularly.  
Otherwise an unexpected malfunction of the system can occur due to a malfunction of the pressure  
switch.  
Perform a proper functional check and leak test after maintenance.  
Stop operation when an abnormality is observed such that the device does not work properly or  
there is a leakage of fluid.  
Otherwise an unexpected malfunction of the system component can occur.  
Release condensed water regularly.  
The flow out of the condensed water to secondary piping can cause a malfunction of pneumatic  
devices.  
Do not use solvents such as benzene or thinner to clean the pressure switch body.  
It can damage the surface of the body and erase the indication on the body.  
Use a soft cloth to remove stains. For heavy stains, use a cloth soaked with diluted neutral detergent  
and fully squeezed, then wipe up the stains again with a dry cloth.  
-6-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model Indication Method  
Model Indication Method  
For positive pressure : I S E 3 0  
01  
01  
25  
25  
M L  
M
For vacuum and low pressure : Z S E 3 0 −  
A
Pipe Specification  
01  
R1/8 (M5 internal thread)  
T1  
NPT1/8(M5 internal thread)  
C4H  
C6H  
N7H  
C4L  
C6L  
N7L  
One-touch fitting φ4, φ5/32inch straight type  
One-touch fitting φ6 straight type  
One-touch fitting φ1/4 inch straight type  
One-touch fitting φ4, φ5/32inch elbow type  
One-touch fitting φ6 elbow type  
One-touch fitting φ1/4 inch elbow type  
Output Specification  
25 NPN output  
65 PNP output  
Unit Specification  
26 1-5V analogue output  
28 4-20mA analogue output  
No  
symbol  
Note1) Unit selection function  
M
Note2) SI units only  
Note1) The new Measurement Law prohibits use in  
Japan of pressure switches with a unit selection  
function.  
Note2) Fixed unit for vacuum and low pressure is : kPa  
for positive pressure is : MPa  
Option 1  
No symbol No Lead wire with connector  
L
Lead wire with connector  
No symbol None  
Option 2  
A
B
Bracket  
Panel Mount Adapter  
Panel Mount Adapter  
+ Front Face Protective Cover  
D
Optional Indications  
Option  
Model number  
Lead Wire with Connector  
Bracket  
ZS-27-A (Lead wire with Connector : 2m)  
ZS-27-B (Contained mounting screws : M3×5L 2pcs.)  
ZS-27-C  
Panel Mount Adapter  
Panel Mount Adapter +  
Front Face Protective Cover  
ZS-27-D  
Front Face Protective Cover ZS-27-01  
Panel Mount Adapter1 ZS-27-02  
-7-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specification  
ZSE30  
100 to 100 kPa  
101 to 101 kPa  
500 kPa  
ISE30  
Rated Pressure Range  
Set Pressure Range  
Withstand Pressure  
-
-
0 to 1 MPa  
0.1 to 1 MPa  
1.5 MPa  
-
Setting and Display Resolution  
0.2 kPa  
0.001 MPa  
Fluids  
Power Supply Voltage  
Current Consumption  
Air, inert gases and incombustible gases  
12 to 24V DC, ±10%,ripple (p p) 10% or less(Protected against inverse connection)  
45mA or less (No load)  
-
Switch Output  
Note 1)  
NPN or PNP open collector output .1 output  
Max. Load Current  
Max. Impressed Voltage  
Residual voltage  
Response Time  
80mA  
30V (During NPN output)  
1V or less (@80mA load current)  
2.5ms or less (chattering-proof function working :20,160,640 or 1280ms selectable)  
Provided  
Short Circuit Protection  
Repeatability  
±0.2%F.S. ±2 digits or less  
±0.2%F.S.±1 digit or less  
Voltage Output  
Note 2)  
Output Voltage : 1 to 5V ±2.5%F.S. or less (within rated pressure range)  
Linearity : ±1%F.S. or less, Output impedance : Approx. 1kΩ  
Output Current : 4 to 20mA ±2.5%F.S. or less (within rated pressure range)  
Linearity : ±1%F.S. or less  
Analog  
Output  
Current Output  
Note 3)  
Max. Load Impedance : 300(@12VDC), 600(@24VDC) Min. Load Impedance : 50Ω  
Hysteresis Mode  
Hyster  
esis  
Variable(from 0)  
Window Comparator  
Mode  
Display Method  
Indicator Accuracy  
Indicator Lamp  
3.5 digits 7-segment display, dual-color display(red/green) Sampling rate:5 times/1 sec  
±2%F.S. ±2 digits (@25±3°C)  
±2%F.S. ±1 digit (@25±3°C)  
Lit when ON (Green)  
Temperature Characteristic  
Enclosure  
±2%F.S. or less (@25°C reference)  
IP40  
Ambient Temperature  
Ambient Humidity  
Withstand Voltage  
Insulation Resistance  
Vibration proof  
Operation : 0 to 50°C, Storage :  
-
10 to 60°C (No condensation or no freezing)  
OperationStorage : 35 to 85%RH (No condensation)  
1000VAC,1 minute (between lead block and case)  
50Mor more @500VDC M (between lead block and case)  
10 to 150 Hz, 1.5mm double amplitude, 2 hours each in directions of X, Y and Z respectively  
100m/s2, 3 times each in directions of X, Y and Z respectively  
CE marking, UL/CSA(E216656)  
Impact proof  
Standard  
Note 1) Analog output cannot be selected when switch output is selected.  
Note 2) Both switch output and current output cannot be selected simultaneously when voltage output is  
selected.  
Note 3) Both switch output and voltage output cannot be selected simultaneously when current output is  
selected.  
Piping specification  
Model  
01  
T1  
C4H  
C6H  
N7H  
C4L  
C6L  
N7L  
R1/8  
NPT1/8  
Port size  
M5×0.8 M5×0.8  
One-touch fitting  
straight type  
φ4mm  
φ5/32inch  
φ6mm φ1/4inch  
One-touch fitting  
elbow type  
φ4mm  
φ5/32inch  
φ6mm φ1/4inch  
Sensor pressure sensing part: silicone, Pipe port: C3602 (electroless nickel plating),  
Material  
O-ring: HNBR  
O-ring: NBR  
O-ring: NBR, Fitting: PBT  
Lead wires with  
connector included (2m)  
81g  
76g  
78g  
Mass  
(Weight)  
Lead wires with  
43g  
38g  
40g  
connector not included  
-8-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Full View with Dimensions  
Dimensions of Main Unit  
-9-  
PS##-OMF0010-B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bracket supplied  
Panel Mount Type  
With Front face protective  
-10-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Panel Cut Dimensioms  
-11-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Names and Function of Individual Parts  
Operation Indicator Lamp : Displays switch operation condition.  
(Green LCD)  
LCD Display : Displays the current status of pressure, setting mode, selected indication unit and error  
code. Four display modes can be selected: display always in red or green only, or changing  
from green to red linked to output.  
Please refer to the matter and the attached table concerning the setting since 17 page  
for displayed character and value.  
Button : Increases the mode and ON/OFF set value. Press this button to change to the peak display  
mode.  
Button : Decreases the mode and ON/OFF set value. Press this button to change to the bottom  
display mode.  
Button : Press this button to change to either mode and to set a set value.  
-12-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Install using the special bracket (Article No.ZS 27 B) or the panel mount adapter (Article No.ZS 27 C)  
available as options.  
Caution : Tighten the pipe port at a clamping torque of 7 to 9Nm.  
Fasten the bracket mounting screws at a clamping torque of 0.5 to 0.7Nm.  
Mounting by Bracket  
Mount the bracket on the main unit using the two  
mounting screws M3 × 5L and install on the facility  
using hexagon socket head cap screws.  
Mounting procedure with the panel mount adapter  
1. Mount the panel mount adapter (1) to the switch display  
side.  
Mount the panel mount adapter so that the adapter hook  
engage with the groove of the switch.  
2. Insert the switch from the front of the panel  
for the switch mount hole.  
3. Mount the panel mount adapter (2) to the switch  
from the back of the panel.  
Press the panel mount adapter (2) with a driver  
to the panel for secure mount.  
Panel mount adapter (2) can be mounted even  
when rotated 90°.  
4. Play can be reduced by using attached tapping screw.  
-13-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notice when removing the switch  
Digital pressure switch with adapter for panel mounting can be removed from facility by making  
hook of the switch wide as following.  
Pressure switch and Panel mount adapter may be damaged it you picked up the hook.  
Piping connections  
Cut the tube perpendicularly.  
Grasp the tube, slowly push it into the One-touch fittings until it comes to a stop.  
tube  
One-touch fitting  
-14-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Example of Internal Circuit and Wiring  
Output Specification  
When the Lead wire with connector provided by SMC CORPORATION is used, the colors of wire  
(Brown, Black, Blue) will apply as shown on circuit diagram.  
PS##-OMF0010-C  
-15-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connector  
Connector Connecting/Disconnecting  
When connecting the connector, insert it straight onto the pin holding the lever and connector body  
between fingers and lock the connector by pushing the lever claw into the square groove in the housing.  
When disconnecting the connector, push down the lever by thumb to disengage the lever claw from the  
square groove. Then pull the connector straight out.  
Please refer the table below for the connector cable (without connector).  
Item  
Cable O.D.  
Specification  
φ3.4  
Core no.  
3
Conducted normally  
sectional area  
0.2mm2 (AWG25)  
Complying standard Complies UL2103  
End of terminal  
Use SMC specified connector cable.  
If you need different length of lead wire, please contact to SMC sales person.  
-16-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting  
Setting  
Setting Procedures  
Measurement Mode  
Initialize  
Press the  
button continuously for more than two seconds.  
The display shown at the right will pop up to allow setting of  
a display color.  
In the case that the unit specification of model indication is M,  
the SL units will be fixed. If no symbol is supplied, see  
”Selecting Indication Unit.”  
1. Display Color Setting  
Select a color for the LCD display.  
When changing the display color, press the  
to select a display color.  
or  
button  
Sor (Red/ON)  
Press the  
SoG (Green/ON)  
rED (Red)  
Grn (Green)  
button to set the desired display color and to move on to setting a desired operation mode.  
If the mode is set to analog output , press the  
“Grn (Green) rED (Red), then press the  
available.  
or  
button, to select a desired display color from  
button. Setting of a desired operation mode will become  
2. Operation Mode Setting  
A desired switch operation mode can be selected.  
The operation mode currently selected will be displayed. Select a desired operation mode by pressing  
the  
or  
button.  
(Hysteresis)  
(Window Comparator)  
Press the  
button to move on to setting an output node.  
3. Auto Preset Setting  
A desired output mode can be set freely for switch output.  
The output mode currently selected will be displayed.  
Press the  
or  
button to switch to normal output “no” or reverse output “nC”.  
(Normally open)  
Press the  
(Normally closed)  
button to move on to setting a desired response time.  
-17-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Response Time Setting  
A response time for switch output can be set as user desires.  
Setting of a response time prevents chattering output.  
The response time currently set will be displayed. Select a desired response time by pressing  
the  
or  
button.  
(2.5ms)  
(20ms)  
(160ms)  
(640ms)  
(1280ms)  
Press the  
button to set and move on to setting Auto Preset mode.  
If the operating mode is set to Hysteresis, press the  
button to set and return to Measurement mode.  
5. Auto Preset Setting  
This function stores in the memory a measurement pressure as a reference value when Auto Preset  
input is set.  
The setting currently set will de displayed. Press the  
or  
button to set to Auto Preset.  
(Manual Setting)  
(Auto Preset)  
Press the button to return to the Measurement mode.  
Selecting Indication Unit (If the unit specification of the model indication is without “M”)  
The indication unit can be selected freely.  
Pressing the  
or  
button will change the unit and will automatically convert set values.  
The units will change in the following order : PA GF bAr PSiinH mmH  
Press the  
button to set and to move on to setting a display color.  
Resolution of each units  
Setting and Display  
Resolution  
I S E 3 0  
Z S E 3 0  
Pa  
0.001MPa  
0.2kPa  
0.002  
0.002  
0.05  
2
Kgf/cm2  
0.01  
0.01  
0.2  
bar  
psi  
mmHg  
inchHg  
0.2  
-18-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pressure Setting  
If set to Manual Setting  
Press the  
button in the Measurement mode to display set values.  
“P_1” or “n_1” and the current set value will flicker alternately.  
Press the  
Press the  
button to display the next set value.  
or  
button to enter into the Value Change mode.  
(See “Value Setting”)  
If Hysteresis mode is set  
If the Hysteresis mode is set, “H” and the set value of Hystersis will be  
displayed alternately after the setting for “P  
_
1”.  
button to return to the normal Measurement mode.  
or button to enter into the Value Change mode.  
Press the  
Press the  
(See “Value Setting)  
In case Hysteresis is set at less than or equal to 2 digits, switch output may chatter if  
input pressure fluctuates near the set point.  
If window comparator mode is set  
If the Window comparator mode is set, “P  
set value will be displayed alternately after the setting for “P  
Press the  
Press the  
_
2” or “n  
_
2” and the current  
1”.  
button to display the next set value. (Hysteresis : H)  
or button to enter into the Value Change mode.  
_
(See “Value Setting”)  
Next, “H” and the set value of Hysteresis will be displayed alternately.  
Press the  
Press the  
button to return to the normal Measurement mode.  
or button to enter into the Value Change mode.  
(See “Value Setting”)  
If the initialize value is the Normally Open mode, “P_1” will be displayed. “n_1” will be displayed  
if it is Normally Closed mode. The set pressure value can be checked without holding or stopping  
switch output operation.  
-19-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If set to Auto Preset Mode  
Press the  
button during the Measurement mode to ready Auto Press mode and  
“AP1”will be displayed. Setting pressure in this condition will ready the equipment.  
Press the  
measurement mode.  
To execute Auto Preset, press the  
and  
buttons simultaneously while “AP1” is displayed to return to the  
button and “A1L” will be displayed. Perform  
adsorption and desorption operations. Detection will be made and a set value will be  
stored in the memory automatically.  
Press the  
button while “A1L” is displayed to finish setting and to return to the normal  
measurement mode.  
Value Setting  
To input value for pressure setting or other purposes:  
1. Press the  
2. Press the  
or  
or  
button to enter the Set Value Change mode. The first row will flicker.  
button to set a desired value.  
(No operation within ten seconds after the Set Value Change mode was selected  
results automatic setting of the value appearing in the display window and in charging  
of the mode from Set Value Change mode to Set Value Indication mode.)  
3. Press the  
( If the highest place is zero, “ “ or “ “ will flicker.“ “ means “+zero”,  
“ means “-zero”, " " means "-1")  
(In the case that the button is pressed in the highest place, the first digit will flicker.)  
button continuously for longer than one second to return to displaying  
button to make the value one digit higher flicker.  
4. Press the  
set values.  
Fine Adjustment Mode  
(Fine Adjustment Function of Display Value)  
Press the  
button and  
buttons simultaneously  
for longer than two second in the Measurement mode.  
“FSt” and current pressure Measurement value will be displayed.  
Press the  
or  
button to change the set value.  
If no operation is made for longer than two seconds or press the  
set button, the pressure switch will display the current pressure  
Measurement value which will then flicker adjusted with “FSt”.  
Press the  
which will then flicker alternately with “FSC”.  
Press the button to return to the normal Measurement mode.  
button to display an adjusted  
a
mount  
(percentage),  
This function wake no dispersion each output value.  
It is possible to fine adjustment within ±5% (ISE), ±2.5% (ZSE)  
range of the reading data on the displayed value of pressure sensor.  
Note) When fine adjustment function is conducted, pressure  
setting value is sometimes changed by ±1 digit.  
-20-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Other Function  
Peak And Bottom Hold Display Function  
Maximum and minimum values are always detected and updated during measurement.  
Displayed values can be held. In peak hold, press the  
flicker and to hold the maximum pressure value.  
button for longer than one second to make  
To reset holding, press the  
In bottom hold, press the  
pressure value.  
button again for more than one second. The Measurement mode will be set.  
button for longer than one second to make flicker and to hold the minimum  
To reset holding, press the  
button again more than one second. The Measurement mode will be set.  
Key Lock Function  
This function prevents malfunction such as a set value being changed by  
mistake. Press the button for longer than four seconds to display which  
of “Loc” or “UnL” is currently set.  
Select by pressing the or  
If button operation is not desired, set to “Loc” to set the Lock mode.  
To release key lock, press the button for longer than four seconds to  
button and set by pressing the  
button.  
display the current setting and to “UnL”.  
Zero Clear Function  
A displayed value can be adjusted to zero when pressure to be measured is within ±70digits of the atmospheric  
pressure.  
(The range of ±10% F.S. setting is different depending on the individual product difference)  
This function is useful because it enables detecting pressure fluctuations larger than a certain level without being  
influenced by fluctuations of source pressure. Press continuously the  
and  
buttons simultaneously to reset  
“0” on the display. To return to the Measurement mode, remove the fingers from the buttons.  
Error Display Function  
This function displays error location and nature when a problem or an error occurs.  
Error Name  
Error Display  
Error Nature  
Troubleshooting Method  
Turn the power off and remove the  
Output factor for the overcurrent.  
Then turn the power on.  
A load current of switch output is flow  
80mA or more.  
Overcurrent  
Error  
Pressure more than ±0.071MPa for  
1MPa or more than ±7.1kPa for vacuum  
compared  
with  
the  
atmospheric  
Preform zero-clear operation  
Again after restoring the applied  
Pressure to an atmospheric  
Pressure condition.  
pressure is applied during zero clear  
operation.  
In three seconds, the mode will reset  
to the Measurement mode. ±10%F.S.  
of the setting range changes  
with individual product differences.  
Residual  
Pressure  
Error  
Pressure exceeding the high limit  
of the set pressure range is applied.  
Reset applied pressure to a level  
Within the set pressure range.  
Pressurizing  
Error  
Pressure exceeding the low limit  
of the set pressure range is applied.  
Displayed in the case of an  
internal data error.  
Turn the power off and turn  
it on again.  
If resetting fails, an investigation  
By SMC CORPORATION  
Will be required.  
Displayed in the case of an  
internal data error.  
System Error  
Displayed in the case of an  
internal data error.  
Displayed in the case of an  
internal data error.  
-21-  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Attached Table  
1. Display color  
Setting of figure  
(Display of segment in left end)  
Display  
character  
Display  
Meaning  
Display  
Display  
character  
When turning it on,  
it red displays it.  
Sor  
0
-0  
1
When turning it on,  
it green displays it.  
SoG  
rEd  
Red  
Green  
Grn  
-1  
2.Output mode  
Display  
Setting of figure  
(Display of segment of treble)  
Display  
character  
Meaning  
Display  
character  
Display  
Normal open  
no  
nc  
0.012  
0.345  
0.678  
0.900  
Normal close  
3.Key lock  
Display  
Display  
character  
Meaning  
Lock  
Loc  
Unlock  
UnL  
4. Auto Preset  
Display  
Display  
character  
Meaning  
Auto Preset is selected.  
Aut  
AP1  
A1L  
State of preparation of  
Auto Preset  
Auto Preset is being set.  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.Manual set  
Display  
Display  
character  
Meaning  
Manual set  
mAn  
Hys  
Hysteresis mode  
(Display when operation mode is set)  
Window comparator mode  
(Display when operation mode is set)  
Wnd  
Hysteresis mode and  
Window comparator mode  
(When P_1 of the setting of pressure is  
set, it displays it.)  
P_1  
P_2  
n_1  
Window comparator mode  
(When P_2 of the setting of pressure is  
set, it displays it.)  
Hysteresis mode and  
Window comparator mode  
(When n_1 of the setting of pressure is  
set, it displays it.)  
Window comparator mode  
(When n_2 of the setting of pressure is  
set, it displays it.)  
n_2  
H
Display when pressure is set  
6.Fine Adjustment Mode  
Display  
character  
Display  
Meaning  
When the adjustment amount is  
set and, it displays it in the place  
where the minute adjustment  
mode is selected.  
Fst  
Amount of adjustment  
(Display it by percent. )  
Fsc  
PS##-OMF0010-C  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sennheiser Microphone 500797 User Manual
Sharper Image Headphones SNC100 User Manual
Sharp Projector PG A20X User Manual
Sony Camera Lens SAL 85F28 User Manual
Sony Indoor Furnishings SU RG11M User Manual
Sony Portable DVD Player DVP FX970 User Manual
Sony Stereo Amplifier XM D9001GTR User Manual
Speco Technologies DVR D16RS User Manual
Speco Technologies Security Camera VL 64TP User Manual
St Bernard Software Webcam v701 User Manual