R
FP-P60CX
AIR PURIFIER
OPERATION MANUAL
PURIFICATEUR D'AIR
MANUEL D'UTILISATION
Free standing type
Type mobile
Tipo vertical sin soporte
PURIFICADOR DE AIRE
MANUAL DE USO
This product earned the ENERGY STAR by meeting
strict energy efficiency guidelines set by the US EPA.
US EPA does not endorse any manufacturer claims of
healthier indoor air from the use of this product.
The energy efficiency of this ENERGY STAR qualified
model is measured based on a ratio between the
model’s CADR for Dust and the electrical energy it
consumes, or CADR/Watt.
Ce produit a le droit de porter la marque ENERGY
STAR après avoir répondu à des critères stricts en ce
qui concerne l’efficacité énergétique, tels qu’établis par
l’agence EPAaux É-U. L’agence EPA aux É-U n’appuie
aucunement les témoignages publicitaires du fabricant
indiquant que ce produit rend l’air intérieur des locaux
plus sain.
L’efficacité énergétique de ce modèle, qui bénéficie
de la reconnaissance ENERGY STAR, est mesurée
par le rapport entre le DAP (débit d’air purifié) du
modèle et l’énergie électrique qu’il consomme, soit le
rapport DAP/Watt.
*Plasmacluster is a trademark of
Sharp Corporation.
Download from Www.Somanuals.com. All Manuals Search And Download.
ENGLISH
FEATURES
CONTENTS
Plasmacluster Ion Control
FOR CUSTOMER ASSISTANCE(U.S) ..... E-2
CONSUMER LIMITED WARRANTY(U.S).... E-3
FOR CUSTOMER ASSISTANCE(CANADA) ... E-4
LIMITED WARRANTY(CANADA) ......... E-5
The unit controls the ratio of negative ions and
positive ions depending on the condition of
the room.
• Clean Mode
Approximately the same numbers of positive
and negative ions are discharged.
• Ion Control Mode
IMPORTANT SAFETY INSTRUCTIONS .. E-6
• WARNING ..................................................E-6
• CAUTIONS CONCERNING OPERATION .E-7
• REMOTE CONTROL LIMITATIONS ..........E-7
• INSTALLATION GUIDELINES ...................E-7
• FILTER GUIDELINES ................................E-7
Plenty of negative ions exist in natural
surroundings such as waterfalls or forests. In
this mode, negative ions will be released at
an increased rate, in order to bring the room
air close to this natural environment.
• AUTO Plasmacluster Ion Mode
The unit will switch between Clean Mode and
Ion Control Mode automatically depending
on the amount of impurities in the air detected
by the odor sensor.
PART NAMES........................................ E-8
• MAIN UNIT DISPLAY .................................E-8
• INCLUDED.................................................E-8
• BACK .........................................................E-8
• NIGHT Mode
The fan speed is automatically switched
between NORMAL and SILENT, depending
on the amount of impurities in the air.
The Plasmacluster Indicator Light and Clean-
Sign Light will turn off.
PREPARATION...................................... E-9
• INSERTING BATTERIES
IN THE REMOTE CONTROL ....................E-9
• Filters
1) Pre-Filter
• REMOTE CONTROL USE .........................E-9
• FILTER INSTALLATION .......................... E-10
It collects large particles.
2) Washable Active Carbon Filter
Absorbs odor elements.
OPERATION ........................................ E-12
• MAIN UNIT OPERATION ........................ E-12
• REMOTE CONTROL OPERATION ........ E-14
Washable to maintain optimum
deodrization performance.
3) True HEPA (High Efficiency
Particulate Air) Filter with Micro-
bial Control Filter
CARE AND MAINTENANCE............... E-15
• MAIN UNIT.............................................. E-15
• ODOR SENSOR ..................................... E-15
• FILTER CLEANING................................. E-15
High-efficiency particle collection including
pollen and dust.
• WASHABLE ACTIVE CARBON
FILTER CARE ......................................... E-16
• FILTER REPLACEMENT
Declaration of Conformity
SHARP AIR PURIFIER FP-P60CX
This device complies with Part 18 of FCC rules.
GUIDELINES .......................................... E-17
Responsible Party:
SHARP ELECTRONICS CORPORATION
Sharp Plaza,
Mahwah, New Jersey 07430-2135
TEL: 1-800-BE-SHARP
TROUBLESHOOTING......................... E-18
SPECIFICATIONS ............................... E-19
Declaration of Conformity
SHARP AIR PURIFIER FP-P60CX
This ISM device complies with Canadian ICES-
001
Thank you for purchasing the SHARP Air Puri-
fier. Please read this manual carefully for the
correct usage information. Before using this
product, be sure to read the section: “Important
Safety Instructions.”
Responsible Party:
SHARP ELECTRONICS OF CANADA LTD.
335 Britannia Road East Mississauga, Ontario
L4Z 1W9 Canada
After reading this manual, retain it in a conven-
ient location for future reference.
TEL: (905) 568-7140
E-1
Download from Www.Somanuals.com. All Manuals Search And Download.
FOR CUSTOMER ASSISTANCE (the United States)
To aid in answering questions if you call for service or for reporting loss or theft, please use
the space below to record the model and serial number located on the back side of the unit.
MODEL NUMBER
SERIAL NUMBER
DATE OF PURCHASE
Dealer Name
Address
City
State
Zip
Telephone
TO PHONE: Dial 1-800-BE-SHARP (237-4277) for:
SERVICE (for your nearest Sharp Authorized Servicer)
PARTS (for your Authorized Parts Distributor)
ACCESSORIES
ADDITIONAL CUSTOMER INFORMATION
TO WRITE: For service problems, warranty information, missing items and other assistance:
Sharp Electronics Corporation
Customer Assistance Center
1300 Naperville Drive
Romeoville, IL 60446-1091
Please provide the following information when you write or call: model number, serial
number, date of purchase, your complete mailing address (including zip code), your daytime
telephone number (including area code) and description of the problem.
Download from Www.SomanualsE.co-m2. All Manuals Search And Download.
CONSUMER LIMITED WARRANTY
CONSUMER LIMITED WARRANTY FOR U.S. USERS
SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the
“Product”), when shipped in its original container, will be free from defective workmanship and materials, and agrees that
it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured
equivalent at no charge to the purchaser for parts or labor for the period(s) set forth below.
This warranty does not apply to any appearance items of the Product nor to the additional excluded item(s) set forth below
nor to any Product the exterior of which has been damaged or defaced, which has been subjected to improper voltage or
other misuse, abnormal service or handling, or which has been altered or modified in design or construction.
In order to enforce the rights under this limited warranty, the purchaser should follow the steps set forth below and provide
proof of purchase to the servicer.
The limited warranty described herein is in addition to whatever implied warranties may be granted to purchasers by law.
ALL IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE ARE
LIMITED TO THE PERIOD(S) FROM THE DATE OF PURCHASE SET FORTH BELOW. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
Neither the sales personnel of the seller nor any other person is authorized to make any warranties other than those
described herein, or to extend the duration of any warranties beyond the time period described herein on behalf of Sharp.
The warranties described herein shall be the sole and exclusive warranties granted by Sharp and shall be the sole and
exclusive remedy available to the purchaser. Correction of defects, in the manner and for the period of time described
herein, shall constitute complete fulfillment of all liabilities and responsibilities of Sharp to the purchaser with respect to the
Product, and shall constitute full satisfaction of all claims, whether based on contract, negligence, strict liability or
otherwise. In no event shall Sharp be liable, or in any way responsible, for any damages or defects in the Product which
were caused by repairs or attempted repairs performed by anyone other than an authorized servicer. Nor shall Sharp be
liable or in any way responsible for any incidental or consequential economic or property damage. Some states do not
allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you.
THIS WARRANTY GIVES YOU SPECIFlC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY
FROM STATE TO STATE.
FP-P60CX Air Purifier. Be sure to have this information available when
you need service for your Product.
Your Product Model Number & Description:
Warranty Period for this Product:
One (1) year parts and labor from date of purchase.
Appearance items of the Product, filters, accessories, or any printed
materials. Product which has been used for rental and/or commercial
purposes.
Additional Item(s) Excluded From Warranty
Coverage:
Where to Obtain Service:
From a Sharp Authorized Servicer located in the United States. To find
the location of the nearest Sharp Authorized Servicer, call Sharp Toll Free
at 1-800-BE-SHARP.
What to Do to Obtain Service:
Ship prepaid or carry in your Product to a Sharp Authorized Servicer. Be
sure to have Proof of Purchase available. If you ship the Product, be sure
it is insured and packaged securely.
TO OBTAIN SUPPLY, ACCESSORY OR PRODUCT INFORMATION, CALL 1-800-BE-SHARP, OR VISIT OUR WEBSITE AT
R
SHARP ELECTRONICS CORPORATION
Sharp Plaza, Mahwah, New Jersey 07430-2135
Download from Www.SomanualsE.co-m3. All Manuals Search And Download.
FOR CUSTOMER ASSISTANCE (Canada)
To aid in answering questions if you call for service or for reporting loss or theft, please use
the space below to record the model and serial number located on the back side of the unit.
MODEL NUMBER
SERIAL NUMBER
DATE OF PURCHASE
Dealer Name
Address
City
Province
Postal Code
Telephone
TO PHONE: Dial 1-905-568-7140 for:
SERVICE (for your nearest Sharp Authorized Servicer)
PARTS (for your Authorized Parts Distributor)
ACCESSORIES
ADDITIONAL CUSTOMER INFORMATION
TO WRITE: For service problems, warranty information, missing items and other assistance:
Sharp Electronics of Canada Ltd.
Customer Care
335 Britannia Road East
Mississauga, Ontario L4Z 1W9
Please provide the following information when you write or call: model number, serial number,
date of purchase, your complete mailing address (including Postal Code), your daytime
telephone number (including area code) and description of the problem.
E-4
Download from Www.Somanuals.com. All Manuals Search And Download.
R
LIMITED WARRANTY (VALID IN CANADA ONLY)
Consumer Electronics Products
Congratulations on your purchase!
Sharp Electronics of Canada Ltd. (hereinafter called “Sharp”) gives the following express warranty to the first consumer
purchaser for this Sharp brand product, when shipped in its original container and sold or distributed in Canada by
Sharp or by an Authorized Sharp Dealer:
Sharp warrants that this product is free, under normal use and maintenance, from any defects in material and
workmanship. If any such defects should be found in this product within the applicable warranty period, Sharp shall, at
its option, repair or replace the product as specified herein.
This warranty shall not apply to:
(a) Any defects caused or repairs required as a result of abusive operation, negligence, accident, improper
installation or inappropriate use as outlined in the owner’s manual.
(b) Any Sharp product tampered with modified, adjusted or repaired by any party other than Sharp, Sharp’s
Authorized Service Centres or Sharp’s Authorized Servicing Dealers.
(c) Damage caused or repairs required as a result of the use with items not specified or approved by Sharp, including
but not limited to head cleaning tapes and chemical cleaning agents.
(d) Any replacement of accessories, glassware, consumable or peripheral items required through normal use of the
product including but not limited to earphones, remote controls, AC adapters, batteries, temperature probe, stylus,
trays, filters, belts, ribbons, cables and paper.
(e) Any cosmetic damage to the surface or exterior that has been defaced or caused by normal wear and tear.
(f) Any damage caused by external or environmental conditions, including but not limited to transmission line/power
line voltage or liquid spillage.
(g) Any product received without appropriate model, serial number and CSA and/or cUL markings.
(h) Any products used for rental or commercial purposes.
(i) Any installation, setup and/or programming charges.
Should this Sharp product fail to operate during the warranty period, warranty service may be obtained upon delivery
of the Sharp product together with proof of purchase and a copy of this LIMITED WARRANTY statement to an
Authorized Sharp Service Centre or an Authorized Sharp Servicing Dealer. In home warranty service may be provided
at Sharp’s discretion on any Sharp television with the screen size of 27” or larger and on any Sharp Over-the-Range
Microwave Oven.
This warranty constitutes the entire express warranty granted by Sharp and no other dealer, service centre or their
agent or employee is authorized to extend, enlarge or transfer this warranty on behalf of Sharp. To the extent the law
permits, Sharp disclaims any and all liability for direct or indirect damages or losses or for any incidental, special or
consequential damages or loss of profits resulting from a defect in material or workmanship relating to the product,
including damages for the loss of time or use of this Sharp product or the loss of information. The purchaser will be
responsible for any removal, reinstallation, transportation and insurance costs incurred. Correction of defects, in the
manner and period of time described herein, constitute complete fulfillment of all obligations and responsibilities of
Sharp to the purchaser with respect to the product and shall constitute full satisfaction of all claims, whether based on
contract, negligence, strict liability or otherwise.
WARRANTY PERIODS:
Parts & Labour (exceptions noted)
1 year
1 year
1 year
Audio Products
Camcorder
DVD Products
LCD Projector
LCD TV
1 year (lamp 90 days)
1 year
Microwave Oven
Television Products
VCR Products
Vacuum Cleaner
Air Purifier & Air Conditioners
1 years (magnetron component-4 additional years)
1 year (picture tube component-1 additional year)
1 year
1 year
1 year (except filters)
To obtain the name and address of the nearest Authorized Sharp Service Centre or Dealer, please contact:
SHARP ELECTRONICS OF CANADA LTD. 335 Britannia Road, East Mississauga, Ontario L4Z 1W9
For more information on this Warranty, Sharp Canada Products,
Accessory Sales, Dealer or Service Locations, please call
(905)568-7140
Visit our Web site: www.sharp.ca
SERVICE
G
T
R
M
E-5
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the
following:
WARNING - To reduce the risk of electrical shock, fire or injury to persons:
• Read all instructions before using the air purifier.
• Use only a 120 volt outlet.
• The air purifier has a polarized plug (one blade is wider than the other is). This plug will fit in a
polarized outlet only one way. Initially, if the plug does not fit into the outlet, reverse it. If it still does not
fit, contact a qualified electrician or service person.
• Do not use the air purifier if the power cord or plug is damaged or the connection to the wall
outlet is loose.
• Periodically remove dust from the power plug.
• Do not insert fingers or foreign objects into the intake or air outlet.
• When removing the power plug, always hold the plug and never pull the cord.
Electrical shock and/or fire from short circuit may occur as a result.
• Do not remove the power plug when your hands are wet.
• Do not use this air purifier near gas appliances or fireplaces.
• Remove the power plug from the wall outlet before cleaning the unit and when not using the
unit.
Electrical shock from bad insulation and/or fire from short circuit may occur as a result.
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent,
Sharp authorized Service Center or similarly qualified person in order to avoid a hazard.
• Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense,
sparks from lit cigarettes, chemical fumes in the air or under a humid condition.
• Be cautions when cleaning the air purifier. Strong corrosive cleansers may damage the exterior.
• Only Sharp Authorized Service Centre should service this air purifier. Contact the nearest Service
Centre for any problems, adjustments, or repairs.
• The batteries must be removed from the remote control before disposal, and the batteries must be
disposed of safely.
NOTE - Radio or TV Interference
If this air purifier should cause interference to radio or television reception, try to correct the interference
by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the air purifier and radio/TV receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is con-
nected.
• Consult the dealer or an experienced radio/TV technician for help.
This product fulfils the requirement of the International standard CISPR 11.
In conformity with this standard, this product is classified as group 2 class B equipment.
Group 2 means that the equipment intentionally generates radio-frequency in the form of electromagnetic
radiation for electro-discharge machining equipment.
Class B equipment means that the equipment suitable to be used in domestic establishments.
E-6
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTIONS CONCERNING OPERATION
• Do not block the intake and air outlet.
• Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into
contact with steam.
• Do not lay the unit down when using.
• Always hold the handle on the back of the main unit when moving it.
Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in
bodily injury.
• Do not operate the unit without the filter.
• Do not wash and reuse HEPA filter.
Not only does it not improve filter performance, it may cause electric shock or malfunction.
• Clean the exterior with a soft cloth only.
The unit surface may be damaged or cracked.
In addition, the sensor may malfunction as a result.
REMOTE CONTROL LIMITATIONS
DO NOT USE THE REMOTE CONTROL IN THE FOLLOWING LOCATIONS:
• Any location where there is inverter lighting equipment or electronic spontaneous lighting
equipment
The remote control may become inoperative. In this case, move away from such lighting equipment
or change direction.
• Location exposed to direct sunlight or fluorescent.
The unit may not receive signals from the remote control.
INSTALLATION GUIDELINES
• During the operation of the product, please place the unit at least 7feet(2m) away from
equipment which involve electric wave such as televisions, radios or wave clocks, in case
electrical interference occurs to such equipment.
• Avoid a location where the sensor is exposed to direct wind.
The unit may not operate properly.
• Avoid locations where curtains, etc., come into contact with the intake or air outlet.
Curtains, etc., may become dirty or a malfunction may occur.
• Avoid locations where the unit is exposed to condensation, due to drastic temperature changes.
(Use under appropriate conditions between 0 and 35˚C in the room.)
• Place on a stable surface with sufficient air circulation.
When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly.
• Do not install when there is generation of lampblack, such as in a kitchen, etc.
The unit surface may crack or the sensor may malfunction as a result.
• Leave about 2feet(60cm) of space from the wall.
The wall behind the air outlet may become dirty as time passes. When using the unit for extended
period of time in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In
addition, periodically clean the wall.
FILTER GUIDELINES
• Follow the instructions in this manual for correct care and maintenance of the filters.
E-7
Download from Www.Somanuals.com. All Manuals Search And Download.
PART NAMES
MAIN UNIT DISPLAY
AUTO Operation Indicator Light
Remote Control Receiver
CLEAN FILTER Indicator Light
NIGHT MODE Indicator Light
QUICK CLEAN operation Indica-
tor Light
CLEAN-SIGN Light
POLLEN Mode Indicator Light
Fan Speed Indicator
Lights
OFF Timer Display In-
dicator Lights
Filter Reset Button
Plasmacluster Indicator
Light
POWER ON/OFF Button
MODE Selection Button
Odor Sensor
Main Unit
Filter Frame
True HEPA Filter (white)
Washable Active Carbon Filter (black)
Pre-Filter
Front Panel
Hook
Remote Control
Handle
BACK
Air Outlet
Date Label
INCLUDED
Power Cord
Power Plug
Remote Control (1 unit)
Battery (AA battery x 2 )
• Operation manual
(Shape of plug depends on country.)
Download from Www.Somanuals.Eco-m8. All Manuals Search And Download.
PREPARATION
INSERTING BATTERIES IN THE REMOTE CONTROL
Remove the back cover
Press and slide the back cover to
remove.
1
Insert batteries
Insert batteries with
shown below.
2
and
as
Close the back cover
3
Battery Information
• The battery life is about 1 year.
• The batteries for this remote control are for initial use only . Change the batteries
when necessary.
• Incorrect usage of the batteries may cause battery fluid leakage and/or damage.
Take care of the following when handling:
• When replacing the batteries, replace both batteries with new ones of the same
type. (Use 2 AA manganese batteries.)
• When not using the unit or remote control for an extended period, remove the
batteries.
REMOTE CONTROL USE
• Operate the remote control facing the main unit
receiver.
•The signal range is about 23 feet (7m).
OPERATION
Receiver
•Make sure there are no objects blocking the
path of the signal.
•A beep sound will be heard from the main unit
when a signal is received.
Transmitter
NOTE
•Avoid dropping or damaging the remote
control, using in a high humidity condition, in
direct sunlight or near a heat source.
E-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Be sure to remove the power plug from the wall outlet.
PREPARATION
FILTER INSTALLATION
To maintain the quality of the filters, they are installed in the main unit and packed in
plastic bags. Be sure to remove the filters from the plastic bags before using the unit.
Remove the filters
1
Front Panel
Remove the Front
Panel.
1
2
1
Pull the bottom of the
Front Panel.
1
2
1
Hook
Pull out the Filter Frame and remove the Pre-Filter,
Active Carbon Filter and True HEPA Filter.
2
1
Filter Frame
Pre-Filter
2
Remove the Active Carbon Filter
(black) and True HEPA Filter (white)
from the plastic bags.
3
True HEPA Filter
Active Carbon Filter
Pre-Filter
Active Carbon Filter
True HEPA Filter
Filter Frame
E-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Install the filters
2
HEPA Filter
Filter Frame
Place the True HEPA Filter
within the Filter Frame with
the tabs facing up.
1
Do not install the filter backwards or
the unit will not operate properly.
Band
Place the Active Carbon Filter
on top of the True HEPA Fil-
ter with the bands (2 places)
facing up.
2
3
Active Carbon Filter
True HEPA Filter
Filter Frame
Place the Pre-filter through
the bands (2 places) located
at the corners of the Active
Carbon Filter.
Tabs (4 places)
Band
Insert the tabs of the pre-filter into
the associated holes of the Filter
Frame.
Holes
Mount the Filter Frame to
the main unit.
4
5
6
Main unit
Fix the Front Panel to the main
unit.
Filter Frame
Band
Fill in the usage start date
on the Date Label.
Use the date as a guide for the
Filter Replacement schedule.
Date Label
Download from Www.Somanuals.Eco-m1. 1All Manuals Search And Download.
Main Unit Controls
OPERATION
• AUTO
• QUICK CLEAN
• POLLEN
• SILENT
• MEDIUM
• MAX
• NIGHT MODE
MAIN UNIT OPERATION
CLEAN FILTER Indicator Light
NIGHT MODE Indicator Light
MODE Selection Button
Power ON/OFF Button
CLEAN SIGN Light
Plasmacluster Indicator Light
1
2
Plasmacluster
Power ON/OFF Button
1
2
• Used to start operation (short beep) and stop operation (long beep)
• Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off.
• Unless unplug the power cord, is unplugged the operation starts in the previous
mode the unit was operated in.
MODE Selection Button
• The operation mode can be switched, and the Indicator Light will turn on.
AUTO operation
NIGHT MODE Operation
The fan speed is automatically switched
(HIGH*, MEDIUM, SILENT) depending
on the amount of impurities in the air.
The sensors detect the impurities for ef-
ficient air purification.
The fan speed is automatically
switched between MEDIUM and
SILENT, depending on the
amount of impurities in the air.
The Plasmacluster Indicator
Light and Clean-Sign Light will
turn off.
QUICK CLEAN operation
The unit will operate at HIGH* fan speed
for 15 minutes, then will operate at Auto
operation.
The operation mode is effective when
quick removal of impurities in the air is
desired.
MAX operation
The unit will operate at a fan
speed of MAX.
MEDIUM operation
POLLEN mode operation
The unit will operate at a fan
speed of MEDIUM.
The unit will operate at HIGH* fan speed
for 10 minutes, then will alternate
between NORMAL and HIGH for 20
minutes.
SILENT operation
The unit will operate quietly
using minimal air intake.
10 minutes: HIGH fan speed
20 minutes: MEDIUM fan speed
20 minutes: HIGH fan speed
* HIGH fan speed is an intermediate
speed between MEDIUM and MAX.
E-12
Download from Www.Somanuals.com. All Manuals Search And Download.
PLASMACLUSTER INDICATOR LIGHT
Plasmacluster ion operation is selected using the remote control.
Blue light
When the Plasmacluster ion operation is in Clean Mode, or in AUTO Plasmacluster Ion Mode and the air
in the room is impure, the Plasmacluster ions will be released continuosly.
Green light
When the Plasmacluster ion operation is in the Ion Control Mode, or in AUTO Plasmacluster Ion Mode
and the air in the room is clean, this light will be activated and the unit will operate in Ion Control Mode.
Light off
There are no Plasmacluster ions being generated.
• The light can be turned off by using the ‘LIGHTS ON/OFF Button’ on the Remote Control. In this case,
Plasmacluster ions are generated.
(Please turn off the light if desired.)
CLEAN-SIGN LIGHT
The color changes according to the air condition.
Clean (Green)
Slightly Impure (Orange)
Very Impure (Red)
ABOUT THE CLEAN-SIGN
• The condition of the CLEAN-SIGN depends on the room air condition detected by the Odor Sensor
when the plug is inserted into the wall outlet.
• It is possible to have a green CLEAN-SIGN with impurities in the air at the time that the air purifier was
just introduced to the room environment. After a while, however, the base impurity rate will be adjusted
to detect room air condition correctly.
• Use the Lights ON/OFF Button on the remote control to turn off the Indicator lights if desired.
DETERMINING THE BASE IMPURITY RATE
For the first 30 seconds after the power plug is inserted into the wall outlet, the unit will check the condi-
tions of the air. If operation is set to ON during this time, the CLEAN-SIGN LIGHT will alternately flash in
green, orange and red.
CLEAN FILTER INDICATOR LIGHT
Clean the Pre-Filter and the Active Carbon Filter when the CLEAN FILTER Indicator Light is on.
(The indicator light will be activated in about 2 months, when using the unit for 24 hours a day.)
(See Page E-16)
Download from Www.SomanualsE.co-m1.3All Manuals Search And Download.
Operations available with
the Remote Control
• AUTO
OPERATION
• MANUAL
• POLLEN
• OFF TIMER
• NIGHT MODE
• Quick CLEAN
• LIGHTS ON/OFF
REMOTE CONTROL OPERATION
Plasmacluster Ion mode
selections
• AUTO
• CLEAN
• ION CONTROL
• OFF
POWER ON/OFF Button
• When you press the
POWER ON/OFF Button, a
short beep will sound and
operation will start in AUTO
Mode.
Transmitter
• Unless the power cord has
been unplugged the
operation starts from the
previous mode the unit was
operated in.
Filter Reset Button
When the Washable Active
Carbon Filter is cleaned and
reinserted into the main unit,
press the Filter Reset Button.
• To stop, press the POWER
ON/OFF Button again.
A long beep will sound and
operation will stop.
Pollen Mode Operation
Button
See Page E-12
Auto (Fan Speed) Button
The fan speed switches au-
tomatically depending on the
amount of impurities in the air.
Off Timer Button
Manual (Fan Speed) Button
The set time switches every time
the button is pressed as shown
below.
The fan speed can be
switched among SILENT,
MEDIUM and MAX settings.
4hours
1 hour
NIGHT MODE Button
See page E-12
8 hours
Cancel
QUICK CLEAN Button
See page E-12
• The indicator light shows the
remaining time.
• The unit will stop operation
when the time is up.
LIGHTS ON/OFF Button
Switches the Plasmacluster
Indicator Light and CLEAN-
SIGN Light either ON or OFF.
Plasmacluster Ion Mode Selections
AUTO
CLEAN
When pressed, the unit will switch between Clean
Mode and the Ion Control Mode automatically de-
pending on the amount of impurities in the air as
detected by the odor sensor. Clean Mode will op-
erate for 1 minute when the Auto function is
selected.
When pressed, the unit will constantly
operate in the Clean Mode, in which
the same numbers of positive and
negative ions are discharged. The
Plasmacluster Indicator Light is blue.
OFF
ION CONTROL
The generation of ions will be
ceased and the Plasmacluster
Indicator Light will go out.
When pressed, the unit will constantly operate in
Ion Control Mode.
The Plasmacluster Ion Indicator Light is green.
E-14
Download from Www.Somanuals.com. All Manuals Search And Download.
CARE AND MAINTENANCE
To maintain optimum performance of this air purifier, please clean the unit including
the sensor and filters periodically.
When cleaning the unit, be sure to unplug the power cord, and never handle the plug
with wet hands. Electrical shock and/or bodily injury may occur as a result.
MAIN UNIT
Care Cycle 1 month
To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to
remain, they may become hard to clean.
Wipe with a dry, soft cloth
For stubborn stains or dirt, use a soft cloth dampened with warm water.
Do not use volatile fluids
Benzene, paint thinner, polishing powder, etc., may damage the surface.
Do not use detergents
Detergent ingredients may damage the unit.
Keep the unit away from water
ODOR SENSOR
Care Cycle 2 months
Opening of odor
sensor
The sensitivity of the sensor will become
unstable if the odor sensor is dirty or
blocked. Remove dust from the surfaces
of the sensor openings using a vacuum
cleaner.
FILTER CLEANING
Care Cycle 2 months
Remove the Front Panel, Clean the surface of the Pre-Filter lightly with a vacuum cleaner.
If it is very dirty remove it from the Filter Frame and wash it.
NOTE
• In case of washing, use a soft brush etc. and cold/warm water.
• Metal brushes or scrub brushes may cause damage.
• After washing, leave it in the shade until it is dry. Then place it
back to the frame.
• Never wash or clean the True HEPA Filter using the nozzle of
a vacuum cleaner directly.
This will greatly decrease the performance of the filters.
E-15
Download from Www.Somanuals.com. All Manuals Search And Download.
CARE AND MAINTENANCE
WASHABLE ACTIVE CARBON FILTER CARE
Remove excess water
HAND WASH ONLY!
DO NOT TUMBLE DRY!
5
The filter will be saturated with
water after rinsing. To decrease
drying time, wrap the filter in an
old thick towel so that excess
water can be removed.
Care Cycle
When the CLEAN FILTER Indicator Light
illuminates, this indicates that the filter
needs to be cleaned. If the unit is kept on
24 hours a day then the CLEAN Filter
Indicator Light will be activated in about 2
months.
CAUTION
• Some carbon may ad-
here to the towel, but it
is harmless.
• Do not wring out the
filter.
The CLEAN FILTER Indicator Light is for
reference. Clean the filter as often as nec-
essary when odor persists.
Remove
visible dirt
with a
vacuum
cleaner.
1
Dry the filter outdoors
if possible in a well
ventilated area.
6
CAUTION
Fill a large container up with
warm water, add a mild
kitchen detergent and stir.
Dilute as indicated
on the detergent
container.
• The wet filter is heavy. Fix it securely for drying to
make sure it does not fall down.
• The filter takes longer to dry in winter, and on rainy
days. Wash it on a day when the weather is good
and dry it in the sun.
Move it indoors at night to prevent freezing.
• Dry the filter outdoors in a well ventilated area. If
dried indoors, the water dripping off the filter may
soil your floor.
2
• Make sure that the activated carbon has not shifted
to one side inside the filter. If it has, distribute it
evenly with your fingers.
• Let the filter dry thoroughly.
Allow the filter to soak ap-
proximately 30 minutes be-
fore washing.
If used while the filter is still moist, then the air that
is exhausted from the main unit will have an odor.
It may take 1 or 2 days to dry.
3
If the filter surface
is very dirty, scrub
with an old tooth-
brush.
Reinstalling the Filter.
Reinstall the filter as shown on Page E-10,11
7
8
Once the Active Carbon Filter has
been cleaned, connect the power
cord to the outlet and press the Filter
Reset Button on either the Remote
Control or Main Unit.
• Once the Filter Reset Button has been acti-
vated, you will hear a beep sound that means
the unit has been reset.
CAUTION
Handle with care to
prevent damage to
the activated carbon
particles.
Rinse thoroughly with clean
water
• The Filter indicator light will then go out
automatically.
4
CAUTION
If rinsing in a con-
tainer, be sure to
rinse 3 to 4 times so
that the odor is
rinsed thoroughly
from the filter.
Filter Reset Button
Download from Www.SomanualsE.co-m1.6All Manuals Search And Download.
FILTER REPLACEMENT GUIDELINES
Depending on the usage environment, air outlet odor may become strong
after several months.
If dust or odors cannot be removed easily, replace the filters.
(Refer to please read before operating new Air purifier E-0)
Guide for filter replacement timing
• Filter life can be greatly reduced in poor environments.
The presence of cigarette smoke, pet dander and other concentrations of airborne particles
will cause filters to become clogged in less time. Please check filters regulary and replace as
needed.
• True HEPA Filter
• Active Carbon Filter
Up to 5 years after opening
Up to 5 years after opening
REPLACING THE FILTERS
See page E-10,11 for directions on how
1
to install the filters when replacing.
After replacing the filters:
Be sure to press the Filter Reset Button on either
the Remote Control or Main Unit with the power cord
connected to the outlet.
2
A short beep will be heard and the operation hours
stored in the memory will be reset.
The CLEAN FILTER Indicator Light will then go out
automatically.
Fill in the usage start date of the filters
on the Date Label.
3
Replacement Filters
Model: FZ-P65HFU
Date Label
• True HEPA Filter : 1 unit
• Active Carbon Filter: 1 unit
Please consult your dealer for purchase of
replacement filters.
Disposal of Filters
Please dispose of replaced filters according to the local disposal laws and regulations.
True HEPA Filter materials:
• Filter: Polypropylene
• Frame: Polyester
• Microbial Control Filter: Polypropylene, Polyethylene
Active Carbon Filter Materials:
• Deodorizer: Activated charcoal
• Net: Polypropylene 60%, Polyester 40%
E-17
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
Before calling for repair, please review the list below, since the problem may not be a unit malfunction.
REMEDY (not a malfunction)
SYMPTOM
• Have the batteries been depleted?
• Are the batteries inserted correctly?
• Is a fluorescent light in the room flickering due to service life?
The Remote Control does not
work
Odors and smoke are not
removed
• Clean or Replace the filters if they appear to be heavily soiled.
(Refer to E-16,E-17)
• The air could be impure at the time the unit was plugged in.
(Refer to E-13) Pull out the plug from the electrical outlet, and
insert the plug one minute later.
The CLEAN-SIGN Light
illuminates green even when the
air is impure
• The sensitivity of the sensor becomes unstable when the
opening of the odor sensor is dirty or is clogged.
Clean the dust around the sensor opening using a vacuum
cleaner. (Refer to E-15)
The CLEAN-SIGN Light illuminates
orange or red even when the air is
clean
The Plasmacluster Indicator
Light remains green (or blue)
and does not change
• When in Ion Control Mode ( or Clean Mode), the Plasmacluster
Indicator Light color will not change.
• Clicking sound or ticking sound is emitted when the unit is
generating ions.
A clicking or ticking sound is
heard from the unit
• Check to see if the filters are heavily soiled.
• Clean or Replace the filters.
• Plasmacluster Air Purifiers emit small traces of ozone which
may produce an odor. These ozone emissions are well below
safety levels .
The discharged air has an
aroma or odor.
• Is the unit installed in a location that is difficult for the sensor to
detect cigarette smoke?
• Is the odor sensor opening blocked or clogged?
(In this case, clean the openings.) (Refer to E-15)
The unit does not operate when
cigarette smoke is in the air.
• After replacing filters, connect the power cord to an outlet and
press the Filter Reset Button on the remote control. (Refer to
E-16)
The CLEAN FILTER Indicator
Light remains activated even
after replacing filter.
• Check to see if the Display OFF Mode on the Remote Control
is selected. If so, press the Display ON/OFF Button on the
Remote Control to activate the indicator light.
(Refer to E-14)
The Plasmacluster Indicator
Light or the CLEAN-SIGN Light
will not activate.
ERROR DISPLAY
LAMP INDICATION
REMEDY
Fan motor disconnected or abnormal.
Operation stops.
• Pressing the ON/OFF button will reset the error display, but if
error occurs again, contact the Sharp Service Center.
The “Silent” Fan Speed Indica-
tor Light blinks.
Download from Www.Somanuals.com. All Manuals Search And Download.
E-18
SPECIFICATIONS
Model
FP-P60CX
120V 60Hz
MED
Power supply
Fan Speed Adjustment
MAX
72W
SILENT
4.0 W
Fan
Rated Power
Speed
Operation Fan Speed CFM (m /min)
13 W
3
233(6.6)
52 dBA
109(3.1)
35 dBA
31(0.9)
14 dBA
Noise Level
2)
330sq.ft(31m *1
Applicable Floor Surface
CADR(Dust/Smoke/Pollen)
Cord Length
209 / 213 / 205
5.3ft(2.5m)
16-11/32in(W)x9-1/2in(D)x22-17/32in(H)
415mm(W)x241(D)x572(H)
19.2Ibs(8.7kg)
Dimensions
Weight
Pre-filter & True HEPA with Microbial control
Washable Active Carbon
Dust collection
Filter type
Deodorization
Odor
Sensors
1 / 4 / 8 hours
OFF timer
Pollen / Quick CLEAN / Night Mode operation
Replacement filter [Model : FZ-R65HFU]
Special Program Mode
Optional accessories
•The applicable floor surface area is appropriate for operating the unit of maximum fan speed.
*1
Standby Power
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this
product consumes about 0.3W of standby power.
For energy conservation, unplug the power cord when the unit is not in use.
Download from Www.Somanuals.com. All Manuals Search And Download.
E-19
|