SUPER MICRO Computer Server SC502 200B User Manual

®
SUPER  
SC502 Chassis Series  
SC502-200B  
USER’S MANUAL  
1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Preface  
About This Manual  
This manual is written for professional system integrators and PC technicians. It  
provides information for the installation and use of the SC502 chassis. Installation  
and maintenance should be performed by experienced technicians only.  
Supermicro’s SC502 chassis features a unique and highly-optimized design for low  
wattage processor platforms. The chassis is equipped with a 200W high efficiency  
power supply for superb power savings. High performance fans provide ample  
optimized cooling.  
This document lists compatible parts available when this document was published.  
Always refer to the our Web site for updates on supported parts and configura-  
tions.  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
Manual Organization  
Chapter 1 Introduction  
The first chapter provides a checklist of the main components included with this  
chassis and describes the main features of the SC502 chassis. This chapter also  
includes contact information.  
Chapter 2 System Safety  
This chapter lists warnings, precautions, and system safety. It recommended that  
you thoroughly familiarize yourself installing and servicing this chassis safety pre-  
cautions.  
Chapter 3 Chassis Components  
Refer here for details on this chassis model including the fans, airflow shields, and  
other components.  
Chapter 4 Chassis Setup and Installation  
Follow the procedures given in this chapter when installing, removing, or  
reconfiguring your chassis.  
Chapter 5 Rack Installation  
Refer to this chapter for detailed information on chassis rack installation. You should  
follow the procedures given in this chapter when installing, removing or reconfiguring  
your chassis into a rack environment.  
Appendix A Cables, Screws and other Accessories  
Appendix B: Power Supply Specifications  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Table of Contents  
Chapter 1 Introduction  
1-1  
1-2  
Overview ......................................................................................................... 1-1  
Shipping List.................................................................................................... 1-1  
Part Numbers.................................................................................................. 1-1  
Where to get Replacement Components........................................................ 1-2  
Contacting SuperMicro.................................................................................... 1-3  
1-3  
1-4  
Chapter 2 System Safety  
2-1  
2-2  
2-3  
2-4  
2-5  
2-6  
Overview ......................................................................................................... 2-1  
Warnings and Precautions.............................................................................. 2-1  
Preparing for Setup......................................................................................... 2-1  
Electrical Safety Precautions .......................................................................... 2-2  
General Safety Precautions............................................................................ 2-3  
System Safety................................................................................................. 2-3  
Chapter 3 Chassis Components  
3-1  
3-2  
Overview ......................................................................................................... 3-1  
Components.................................................................................................... 3-1  
Chassis............................................................................................................ 3-1  
Mounting to a Rack (optional)......................................................................... 3-1  
Power Supply.................................................................................................. 3-1  
Where to get Replacement Components........................................................ 3-2  
3-3  
Chapter 4 Chassis Setup and Maintenance  
4-1  
4-2  
4-3  
4-4  
Overview ......................................................................................................... 4-1  
Removing the Chassis Cover ......................................................................... 4-2  
Installing the Hard Drives................................................................................ 4-3  
Installing the Motherboard .............................................................................. 4-4  
Chassis Standoffs ........................................................................................... 4-4  
Motherboard Installation.................................................................................. 4-5  
Add-on Card/Expansion Slot Setup ................................................................ 4-6  
Replacing the Heatsink................................................................................... 4-8  
Checking the Server's Air Flow....................................................................... 4-9  
Power Supply ............................................................................................... 4-10  
Replacing the Power Supply......................................................................... 4-10  
4-5  
4-8  
Chapter 5 Rack Installation  
5-1  
5-2  
5-3  
Overview ......................................................................................................... 5-1  
Unpacking the System.................................................................................... 5-1  
Preparing for Setup......................................................................................... 5-1  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Choosing a Setup Location............................................................................. 5-1  
Rack Precautions............................................................................................ 5-2  
General Server Precautions............................................................................ 5-2  
Rack Mounting Considerations....................................................................... 5-3  
Ambient Operating Temperature ................................................................ 5-3  
Reduced Airflow ......................................................................................... 5-3  
Mechanical Loading ................................................................................... 5-3  
Circuit Overloading..................................................................................... 5-3  
Rack Mounting Instructions............................................................................. 5-4  
Installing the Chassis into a Rack: ................................................................. 5-4  
Installing the Chassis into a Rack: ................................................................. 5-5  
5-4  
Appendix A Cables, Screws, and other Accessories  
Appendix B Power Supply Specifications  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Introduction  
Chapter 1  
Introduction  
1-1 Overview  
Supermicro’s SC502 chassis features a unique and highly-optimized design. The  
chassis is equipped with high efficiency 80%+ low noise power supply.  
1-2 Shipping List  
Part Numbers  
Please visit the following link for the latest shiping lists and part numbers for your  
SC502-200B Chassis  
Power  
Supply  
Model  
CPU  
HDD  
I/O Slots  
1 Fixed 3.5"  
hard drive or  
up to 2 fixed  
2.5" hard  
1x FH  
(optional)  
200W  
Intel Celeron 400  
series (35W) or  
low power plat-  
forms under 20W  
SC502-200(B)  
drives  
IMPORTANT: It is critical to choose the correct heatsink for your motherboard, that  
will fit in the SC502 chassis.  
1. Intel Celeron 400 seriew (35W) platform: Active heatsink SNKP0032A4  
2. Low power platforms under 20W: Passive heatsink SNKP0016P  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
1-3 Where to get Replacement Components  
Though not frequently, you may need replacement parts for your system. To en-  
sure the highest level of professional service and technical support, we strongly  
recommend purchasing exclusively from our Supermicro Authorized Distributors /  
System Integrators / Resellers. A list of Supermicro Authorized Distributors / System  
to Buy link.  
1-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Introduction  
1-4 Contacting SuperMicro  
Headquarters  
Address:  
Super Micro Computer, Inc.  
980 Rock Ave.  
San Jose, CA 95131 U.S.A.  
Tel:  
+1 (408) 503-8000  
+1 (408) 503-8008  
Fax:  
Email:  
[email protected] (General Information)  
[email protected] (Technical Support)  
Web Site:  
Europe  
Address:  
Super Micro Computer B.V.  
Het Sterrenbeeld 28, 5215 ML  
's-Hertogenbosch, The Netherlands  
Tel:  
+31 (0) 73-6400390  
Fax:  
Email:  
+31 (0) 73-6416525  
[email protected] (General Information)  
[email protected] (Technical Support)  
[email protected] (Customer Support)  
Asia-Pacific  
Address:  
Super Micro Computer, Taiwan  
4F, No. 232-1, Liancheng Rd.  
Chung-Ho 235, Taipei County  
Taiwan, R.O.C.  
Tel:  
+886-(2) 8226-3990  
Fax:  
+886-(2) 8226-3991  
Web Site:  
Email:  
Tel:  
[email protected] (Technical Support)  
886-2-8228-1366, ext.132 or 139  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
Notes  
1-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: System Safety  
Chapter 2  
System Safety  
2-1 Overview  
This chapter provides a quick setup checklist to get your chassis up and running.  
Following the steps in order given should enable you to have your chassis setup and  
operational within a minimal amount of time. This quick set up assumes that you are  
an experienced technician, famailiar with common concepts and terminology.  
2-2 Warnings and Precautions  
You should inspect the box the chassis was shipped in and note if it was damaged  
in any way. If the chassis itself shows damage, file a damage claim with carrier  
who delivered your system.  
Decide on a suitable location for the rack unit that will hold that chassis. It should  
be situated in a clean, dust-free area that is well venilated. Avoid areas where heat,  
electrical noise and eletromagnetic fields are generated.  
You will also need it placed near at least one grounded power outlet. When config-  
ured, the SC502 chassis includes one power supply.  
2-3 Preparing for Setup  
The SC502 Chassis bolts directly to a rack and includes the mounting screws you  
will need to install the systems into the rack. Please read this manual in its entirety  
before you begin the installation procedure.  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
2-4 Electrical Safety Precautions  
Basic electrical safety precautions should be followed to protect yourself from harm  
and the SC502 from damage:  
Be aware of the locations of the power on/off switch on the chassis as well  
as the room’s emergency power-off switch, disconnection switch or electrical  
outlet. If an electrical accident occurs, you can then quickly remove power from  
the system.  
Do not work alone when working with high voltage components.  
Power should always be disconnected from the system when removing or in-  
stalling main system components, such as the serverboard, memory modules  
and the DVD-ROM and floppy drives (not necessary for hot swappable drives).  
When disconnecting power, you should first power down the system with the  
operating system and then unplug the power cords from all the power supply  
modules in the system.  
When working around exposed electrical circuits, another person who is fa-  
miliar with the power-off controls should be nearby to switch off the power, if  
necessary.  
Use only one hand when working with powered-on electrical equipment. This  
is to avoid making a complete circuit, which will cause electrical shock. Use  
extreme caution when using metal tools, which can easily damage any electrical  
components or circuit boards they come into contact with.  
Do not use mats designed to decrease electrostatic discharge as protection from  
electrical shock. Instead, use rubber mats that have been specifically designed  
as electrical insulators.  
The power supply power cord must include a grounding plug and must be  
plugged into grounded electrical outlets.  
Serverboard Battery: CAUTION - There is a danger of explosion if the onboard  
battery is installed upside down, which will reverse its polarities This battery  
must be replaced only with the same or an equivalent type recommended by  
the manufacturer. Dispose of used batteries according to the manufacturer’s  
instructions.  
2-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: System Safety  
DVD-ROM Laser: CAUTION - This server may have come equipped with a  
DVD-ROM drive. To prevent direct exposure to the laser beam and hazardous  
radiation exposure, do not open the enclosure or use the unit in any uncon-  
ventional way.  
2-5 General Safety Precautions  
Keep the area around the chassis clean and free of clutter.  
Place the chassis top cover and any system components that have been re-  
moved away from the system or on a table so that they won’t accidentally be  
stepped on.  
While working on the system, do not wear loose clothing such as neckties and  
unbuttoned shirt sleeves, which can come into contact with electrical circuits or  
be pulled into a cooling fan.  
Remove any jewelry or metal objects from your body, which are excellent metal  
conductors that can create short circuits and harm you if they come into contact  
with printed circuit boards or areas where power is present.  
After accessing the inside of the system, close the system back up and secure  
it to the rack unit with the retention screws after ensuring that all connections  
have been made.  
2-6 System Safety  
Electrostatic discharge (ESD) is generated by two objects with different electrical  
charges coming into contact with each other. An electrical discharge is created to  
neutralize this difference, which can damage electronic components and printed  
circuit boards. The following measures are generally sufficient to neutralize this  
difference before contact is made to protect your equipment from ESD:  
Do not use mats designed to decrease electrostatic discharge as protection from  
electrical shock. Instead, use rubber mats that have been specifically designed  
as electrical insulators.  
Use a grounded wrist strap designed to prevent static discharge.  
Keep all components and printed circuit boards (PCBs) in their antistatic bags  
until ready for use.  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
Touch a grounded metal object before removing any board from its antistatic  
bag.  
Do not let components or PCBs come into contact with your clothing, which may  
retain a charge even if you are wearing a wrist strap.  
Handle a board by its edges only; do not touch its components, peripheral chips,  
memory modules or contacts.  
When handling chips or modules, avoid touching their pins.  
Put the serverboard and peripherals back into their antistatic bags when not  
in use.  
For grounding purposes, make sure your computer chassis provides excellent  
conductivity between the power supply, the case, the mounting fasteners and  
the serverboard.  
2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Chassis Components  
Chapter 3  
Chassis Components  
3-1 Overview  
This chapter describes the most common components included with your chassis.  
Some components listed may not be included or compatible with your particular  
chassis model. For more information, see the installation instructions detailed later  
in this manual.  
3-2 Components  
Chassis  
Chassis may include one of the following three options:  
One fixed 3.5" hard drive.  
Up to 2 fixed 2.5" hard drives.  
One FH PCI add-on card  
Mounting to a Rack (optional)  
The SC502 can be placed in a rack for secure storage and use. To setup your  
rack, follow the step-by-step instructions included in this manual.  
Power Supply  
Each SC502 chassis model includes a high-efficiency 80%+ low noise power sup-  
ply with thermal control fan, rated at 200 Watts. In the unlikely event your power  
supply fails, replacement is simple. The power supply simply needs to be unscrewed  
from the chassis and replaced.  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
3-3 Where to get Replacement Components  
Though not frequently, you may need replacement parts for your system. To en-  
sure the highest level of professional service and technical support, we strongly  
recommend purchasing exclusively from our Supermicro Authorized Distributors/  
System Integrators/Resellers. A list of Supermicro Authorized Distributors/System  
to Buy link.  
3-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Chassis Setup and Maintenance  
Chapter 4  
Chassis Setup and Maintenance  
4-1 Overview  
This chapter covers the steps required to install components and perform mainte-  
nance on the chassis. The only tool you will need to install components and perform  
maintenance is a Phillips screwdriver. Print this page to use as a reference while  
setting up your chassis.  
Review the warnings and precautions listed in the manual be-  
fore setting up or servicing this chassis. These include infor-  
mation in Chapter 2: System Safety and the warning/precau-  
tions listed in the setup instructions.  
!
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
4-2 Removing the Chassis Cover  
1
2
1
1
Figure 4-1: Removing the Chassis Cover  
1. Remove the five screws that hold the chassis cover in place.There are two  
screws on each side of the chassis, and one screw on the back.  
2. Once the screws have been removed, lift the cover upward to remove it from  
the chassis.  
Warning: Except for short periods of time, do NOT operate the  
server without the cover in place. The chassis cover must be in  
!
place to allow proper airflow and prevent overheating.  
4-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Chassis Setup and Maintenance  
4-3 Installing the Hard Drives  
The 3.5" hard drive screws  
directly into the chassis  
Figure 4-2: Installing the 3.5" Hard Drive  
The 2.5" hard drives (1) must be installed  
in their bracket (2) before they are  
screwed into the chassis. (Bracket part  
number is MCP-220-00044-0N)  
1
2
Figure 4-3: Installing the 2.5" Hard Drives  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
4-4 Installing the Motherboard  
Chassis Standoffs  
Figure 4-4: Chassis Standoffs  
Chassis Standoffs  
Standoffs prevent short circuits by securing space between the motherboard and the  
chassis surface. The SC502 chassis includes permanent standoffs in locations used  
by Micro ATX 9.6" x 9.6" size motherboards. These standoffs accept the rounded  
Phillips head screws included in the SC502 accessories packaging.  
4-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Chassis Setup and Maintenance  
Motherboard Installation  
1. Review the documentation that came with your motherboard. Become familiar  
with component placement, requirements, precautions, and cable connec-  
tions. The SC502 chassis supports 9.6" x 9.6" Micro ATX motherboards. Refer  
to the Supermicro Web site for details or contact Supermicro for assistance.  
2. Open the chassis cover.  
3. Lay the motherboard on the chassis aligning the board with the standoffs.  
4. Secure the motherboard to the chassis using the rounded, Phillips head  
screws.  
5. Secure the CPU(s), heatsinks, and other components to the motherboard as  
described in the motherboard documentation.  
6. Connect the cables between the motherboard, chassis, front panel, and  
power supply, as needed  
4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
Add-on Card/Expansion Slot Setup  
SC502 chassis includes an I/O slot for the optional add-on card. A full-height, half-  
length PCI add-on card is supported. A riser card is required in order to adapt the  
add-on card to the 1U chassis. For further information on add-on cards and risers  
Add-on Card Clip  
Figure 4-5: Locate the Add-on Card Clip  
1. Locate the add-on card clip on the back of the chassis  
2. Remove the screws holding the add-on card clip and the dummy bracket  
which covers the openings in the back of the chassis.  
3. Remove the add-on card clip and the dummy plate from the chassis.  
4. Outside of the chassis, put the add-on card and the riser card together by  
inserting the add-on card into the riser card.  
Add-on Card Clip  
Add-on/Expansion  
Card Slot  
Figure 4-6: Install the Add-on Card and Riser Card  
4-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Chassis Setup and Maintenance  
5. Insert the assembled add-on card and riser card into the expansion slot inside  
the chassis, carefully aligning the plate of the add-on card with the openings  
in the back of the chassis.  
6. Replace the add-on card clip and screw it onto the chassis to hold the add-on  
card in place.  
Figure 4-7: Replace the Add-on Card  
7. Replace the chassis cover.  
Figure 4-8: Replace the Add-on Card Clip  
4-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
4-5 Installing the Heatsink  
The SC502 Chassis requires that a heatsink be used to conduct heat away from  
the motherboard.  
1. Unplug all power leading to the chassis.  
2. Align the holes of the heatsink with the mounting thru holes in the mother-  
board  
3. Using the screws of the heatsink attach the heatsink to the motherboard.  
Figure 4-9: Installing the Heatsink  
4-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Chassis Setup and Maintenance  
Figure 4-10: Installing an Active Heatsink  
Note:  
Intel Celeron 400 35W platform motherboards may require an optimized design  
(SNK-P0032A4) active heatsink. Refer to Appendix A of this manual for basic  
heatsink information. Refer to your motherboard documentation for detailed heatsink  
information and installation instructions, specific to your motherboard.  
Checking the Server's Air Flow  
1. Make sure there are no objects to obstruct airflow in and out of the server.  
2. Use only recommended server parts.  
3. Make sure no wires or foreign objects obstruct air flow through the chassis.  
Pull all excess cabling out of the airflow path, or use shorter cables.  
4. The control panel LEDs inform you of system status. See “Chapter 3: System  
Interface” for details on the LEDs and the control panel buttons.  
4-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
4-8 Power Supply  
The SC502 chassis has a 200 watt power supply. This power supply is auto-switch-  
ing capable. This enables it to automatically sense and operate at a 100v to 240v  
input voltage.  
The SC502 chassis has one power supply. In the unlikely event that the power  
supply unit fails, the system will shut down and you will need to change the power  
supply unit.  
New units can be ordered directly from Supermicro (see contact information in the  
Preface).  
Replacing the Power Supply  
1. Unplug all power leading to the chassis.  
2. Disconnect all wiring from the power supply.  
3. Remove the four screws which hold the power supply in the chassis. Two rear  
mounting screws are located on the rear of the power supply. Two bottom  
mounting screws are accessed on the underside of the chassis and extend  
Rear Mounting Screws  
Power Supply  
Mounting Thru Holes  
Bottom Mounting Screws  
Figure 4-11: Installing the Power Supply  
4-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Chassis Setup and Maintenance  
upwards through the mounting thru holes, to hold the power supply in place.  
Set the screws aside for later use.  
4. Remove the power supply from the chassis.  
5. Align the mounting thru holes on the power supply with the mounting holes  
in the chassis and reattach the power supply to the chassis using the four  
screws which were previously set aside  
6. Connect the chassis wiring to the power supply.  
4-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
Notes  
4-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 5: Rack Installation  
Chapter 5  
Rack Installation  
5-1 Overview  
This chapter provides a quick setup checklist to get your chassis up and running.  
Following these steps in the order given should enable you to have the system  
operational in a minimal amount of time.  
5-2 Unpacking the System  
You should inspect the box the chassis was shipped in, and note if it was damaged  
in any way. If the chassis itself shows damage, you should file a damage claim with  
the carrier who delivered it.  
Decide on a suitable location for the rack unit that will hold your chassis. It should  
be situated in a clean, dust-free area that is well ventilated. Avoid areas where  
heat, electrical noise and electromagnetic fields are generated. You will also need  
it placed near a grounded power outlet. Be sure to read the Rack and Server Pre-  
cautions in the next section.  
5-3 Preparing for Setup  
The box your chassis was shipped in should include four mounting screws, which  
you will need if you intend to install the system into a rack. Please read this section  
in its entirety before you begin the installation procedure outlined in the sections  
that follow.  
Choosing a Setup Location  
Leave enough clearance in front of the rack to enable you to open the front  
door completely (~25 inches).  
Leave approximately 30 inches of clearance in the back of the rack to allow for  
sufficient airflow and ease in servicing.  
5-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
This product is for installation only in a Restricted Access Location (dedicated  
equipment rooms, service closets and similar environments).  
Warnings and Precautions!  
!
!
Rack Precautions  
Ensure that the leveling jacks on the bottom of the rack are fully extended to  
the floor with the full weight of the rack resting on them.  
In single rack installation, stabilizers should be attached to the rack.  
In multiple rack installations, the racks should be coupled together.  
Always make sure the rack is stable before extending a component from the  
rack.  
You should extend only one component at a time. Extending two or more simul-  
taneously may cause the rack to become unstable.  
General Server Precautions  
Review the electrical and general safety precautions that came with the com-  
ponents you are adding to your chassis.  
Determine the placement of each component in the rack.  
Install the heaviest server components on the bottom of the rack first, and then  
work up.  
Use a regulating, uninterruptible power supply (UPS) to protect the server from  
power surges, voltage spikes and to keep your system operating in case of a  
power failure.  
Allow the hard drives and power supply modules to cool before touching  
them.  
Always keep the rack's front door, all panels and all components on the servers  
closed when not servicing, in order to maintain proper cooling.  
5-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 5: Rack Installation  
Rack Mounting Considerations  
Ambient Operating Temperature  
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-  
ture of the rack environment may be greater than the ambient temperature of the  
room. Therefore, consideration should be given to installing the equipment in an  
environment compatible with the manufacturer’s maximum rated ambient tempera-  
ture (TMRA).  
Reduced Airflow  
Equipment should be mounted into a rack so that the amount of airflow required  
for safe operation is not compromised.  
Mechanical Loading  
Equipment should be mounted into a rack so that a hazardous condition does not  
arise due to uneven mechanical loading.  
Circuit Overloading  
Consideration should be given to the connection of the equipment to the power  
supply circuitry and the effect that any possible overloading of circuits might have  
on overcurrent protection and power supply wiring. Appropriate consideration of  
equipment nameplate ratings should be used when addressing this concern.  
Reliable Ground  
A reliable ground must be maintained at all times. To ensure this, the rack itself  
should be grounded. Particular attention should be given to power supply connec-  
tions other than the direct connections to the branch circuit (for example, the use  
of power strips, and other devices).  
5-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
5-4 Rack Mounting Instructions  
This section provides information on installing the SC502 chassis into a rack unit  
There are a variety of rack units on the market, which may mean the assembly  
procedure will differ slightly. You should also refer to the installation instructions that  
came with the rack unit you are using.  
Figure 5-1: Installing the Chassis into a Rack  
Installing the Chassis into a Rack:  
1. Confirm that chassis includes the four mounting screws required to mount the  
chassis into a rack  
2. Align the thru holes of the chassis with the thru holes of the rack.  
3. Insert the mounting screws into the thru holes in the front of the chassis and  
through the thru holes in the rack  
5-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 5: Rack Installation  
Mid-Mount Telco Rack  
The SC502 supports Telco Rack installation. The SC502 chassis compact design  
allows the chassis to be installed into a Telco rack without the use of rails.  
Figure 5-2: Installing the Chassis into a Telco Rack  
Installing the Chassis into a Rack:  
1. Confirm that chassis includes the four mounting screws required to mount the  
chassis into a rack  
2. Align the thru holes of the chassis with the thru holes of the rack.  
3. Insert the mounting screws into the thru holes in the front of the chassis and  
through the thru holes in the rack  
5-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
Notes  
5-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix A: Chassis Cables  
Appendix A  
Cables, Screws,  
and other Accessories  
A-1 Overview  
This appendix lists supported cables for your chassis system. It only includes the  
most commonly used components and configurations. For more compatible cables,  
refer to the manufacturer of the motherboard you are using and our Web site at:  
A-2 Cables Included with SC502 Chassis  
SC502-200B  
Part #  
CBL-0236L  
-
Type  
Ribbon  
Cable  
Length  
Description  
16 pin to 16 pin ribbon cable for  
control panel  
13"  
6'  
Regional power cord  
A-3 Optional Accessories  
The following accessories are compatible with the SC502 Chassis.  
Hard Drive Carrier (Tray):  
MCP-220-00044-0N 2.5" hard drive carrier. One carrier can hold up to two 2.5"  
hard drives. The SC502 can hold up to two 2.5" hard drive carriers, for a total of  
four hard drives.  
Figure A-1: Hard Driver Carrier (Tray)  
A-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
1U Active Heatsink (SNK-P0032A4)  
It is critical to choose the correct heatsink for your motherboard, that will fit in the  
SC502 chassis.  
1. Intel Celeron 400 seriew (35W) platform: Active heatsink SNKP0032A4  
2. Low power platforms under 20W: Passive heatsink SNKP0016P  
Figure A-2: SNK-P00A4 Active Heatsink  
The SNK-P00A4 active heatsink may only be used on specific motherboards, due  
to its larger 4" x 4" size. This is particularly important in systems utilizing Intel  
Celeron 400 series platforms. To ascertain which heatsink is appropriate for your  
Extending Power Cables  
Although Supermicro chassis are designed with to be efficient and cost-effective,  
some compatible motherboards have power connectors located in different areas.  
To use these motherboards you may have to extend the power cables to the mother  
boards. To do this, use the following chart as a guide.  
Power Cable Extenders  
Number of Pins  
24 pin  
Cable Part #  
CBL - 0042  
CBL - 0059  
CBL - 0062  
CBL - 0060  
Length  
7.9”(20 CM)  
7.9”(20 CM)  
7.9”(20 CM)  
7.9”(20 CM)  
20 pin  
8 pin  
4 pin  
Front Panel to the Motherboard  
The SC502 chassis includes a cable to connect the chassis front panel to the  
motherboard. If your motherboard uses a different connector, use the following list  
to find a compatible cable.  
A-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix A: Chassis Cables  
Front Panel to Motherboard Cable (Ribbon Cable)  
Number of Pins  
(Front Panel)  
Number of Pins  
(Motherboard  
Cable Part #  
16 pin  
16 pin  
20 pin  
16 pin  
20 pin  
16 pin  
20 pin  
CBL - 0049  
CBL - 0048  
CBL - 0047  
CBL - 0068  
CBL - 0067  
20 pin  
various*  
various*  
* Split Cables: Use these cable if your motherboard requires several different con-  
nections from the front panel.  
A-4 Chassis Screws  
The accessory box includes all the screws needed to setup your chassis. This  
section lists and describes the most common screws used. Your chassis may not  
require all the parts listed.  
M/B  
HARD DRIVE  
Flat head  
6-32 x 5 mm  
[0.197]  
Pan head  
6-32 x 5 mm  
[0.197]  
DVD-ROM, CD-ROM, and FLOPPY DRIVE  
Flat head  
6-32 x 5 mm  
[0.197]  
Round head  
M2.6 x 5 mm  
[0.197]  
Pan head  
6-32 x 5 mm  
[0.197]  
Round head  
M3 x 5 mm  
[0.197]  
RAIL  
Flat head  
M4 x 4 mm  
[0.157]  
Round head  
M4 x 4 mm  
[0.157]  
Flat head  
M5 x 12 mm[0.472]  
Washer for M5  
M/B STANDOFFS  
M/B standoff  
6-32 to 6-32  
M/B (CPU)  
standoff  
M5 to 6-32  
1/U M/B standoff  
6-32 x 5 mm  
[0.197]  
Thumb screw  
6-32 x 5 mm  
[0.197]  
A-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
Notes  
A-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix B: Power Supply Specifications  
Appendix B  
Power Supply Specifications  
This appendix lists power supply specifications for your chassis system.  
200W  
MFR Part #  
PWS-201-1H  
100 - 240V  
50 - 60Hz  
4-2Amp  
Rated AC Voltage  
+5V standby 2 Amp  
+12V 16 Amp  
+5V 8 Amp  
+3.3V 8 Amp  
-12V 0.5 Amp  
B-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC502 Chassis Manual  
Notes  
B-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sennheiser Microphone SDC 8000 CV User Manual
Sharp Stereo System HT DD5000 User Manual
Sony Car Satellite TV System STR DB895D User Manual
Sony Car Stereo System SCD CE775 User Manual
Sony CRT Television KDL 40W3000 User Manual
Sony DVD Player DVP NC665P User Manual
Sony Stereo Receiver STR DN1060 STR DN860 User Manual
Sony VCR SLV SX740D E User Manual
Sterling Compact Loader SSIL Series User Manual
Sylvania CD Player SRCD2730 User Manual