Seiko Watch 7T82 User Guide

You are now the proud owner of a SEIKO 1/100-Second Retrograde  
Chronograph Cal. 7T82. For best results, please read the instructions in this  
booklet carefully before using your SEIKO Analogue Quartz Watch. Please  
keep this manual handy for ready reference.  
Es usted ahora el orgulloso propietario del Cronógrafo Retrógrado de 1/100  
de Segundo de SEIKO, Cal. 7T82. Para óptimo resultado, lea detenidamente  
las instrucciones de este folleto antes de usar el reloj. Guarde este manual  
para consulta posterior.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STOPWATCH second hand  
STOPWATCH 1/100-second hand  
CAL. 7T82  
FEATURES  
TIME/CALENDAR  
Hour, minute and small second hands  
STOPWATCH  
STOPWATCH 1/10-second hand  
Minute hand  
A
0
9
1
Hour hand  
8
7
2
3
40-minute measurement in 1/100-second increments, consecutively meas-  
urable up to 120 minutes  
4 STOPWATCH hands  
1/100-second, 1/10-second, second and minute hands  
Split time measurement on demand  
1/100-second high-speed movement  
The STOPWATCH 1/100-second hand makes 10 full circles in one sec-  
ond.  
Date  
1/100 SEC.  
6
4
5
60  
30  
45  
15  
CROWN  
2
10  
30  
40  
MIN.  
a
b
c
Small second hand  
0
a: Normal position:  
b: First click:  
B
Date setting  
c: Second click:  
Time setting,  
40-minute dial with a retrograde minute hand  
When the minute counting reaches 40 minutes, the STOPWATCH minute  
hand immediately returns and continues counting from 41 minutes  
onward. The minute counting is repeated in the same manner for  
another rotation, up to 120 minutes, at that time the stopwatch automati-  
cally stops counting.  
Hand position adjustment  
STOPWATCH minute hand  
If your watch has a screw down crown, refer to "SCREW DOWN CROWN" section  
on the next page.  
Simplified illustrations are used in the following sections of this manual.  
5
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCREW DOWN CROWN  
TIME AND CALENDAR SETTING AND  
STOPWATCH HAND POSITION ADJUSTMENT  
Some models have a screw down crown to prevent accidental operation and help  
maintain water-resistant quality.  
To use the crown, it is necessary to unlock the crown first before pulling it out, and  
it is important to securely screw the crown in after each use.  
STOPWATCH 1/10-second hand  
STOPWATCH second hand  
STOPWATCH 1/100-second hand  
HOW TO OPERATE THE SCREW DOWN CROWN  
0
The crown must be securely locked in the case except when you use it to set the  
watch.  
9
1
Hour hand  
8
7
2
3
Minute hand  
1/10SEC.  
6
4
60  
<How to unlock the crown>  
45  
15  
CROWN  
Small second hand  
30  
2
10  
0
30  
40  
Turn the crown counterclockwise to unscrew it.  
The crown is released and projected outward  
from its original position.  
MIN.  
The crown is unlocked  
and can be pulled out.  
STOPWATCH minute hand  
The crown is locked.  
<How to lock the crown>  
This watch is designed so that the following adjustments are made with the crown  
at the second click position:  
1) time setting  
2) stopwatch hand position adjustment  
Once the crown is pulled out to the second click, be sure to make both the above  
adjustments 1) and 2) at the same time.  
Turn the crown clockwise while pressing it to the  
case until it is screwed all the way in and locked.  
*
When screwing the crown in, ensure that the crown is correctly aligned and turn it  
gently. If it is too hard to turn, unscrew it first, and then rewind it. Do not screw it  
in by force as it may damage the thread of the screw or the case.  
The date adjustment is done with the crown at first click position.  
7
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hour hand  
1) TIME AND CALENDAR SETTING  
CROWN Turn clockwise to advance hour and  
minute hands past 12:00 AM. Doing so  
will advance the date to the current  
date.  
Pull out to first click.  
CROWN  
Turn clockwise until the previous day's  
date appears.  
CROWN  
Current date  
Minute hand  
Previous day's date  
Set the hour and minute hands to the  
desired time taking AM and PM into  
consideration.  
CROWN  
Pull out to second click when the small  
second hand is at the 12 o’clock posi-  
tion. The small second hand will stop  
on the spot.  
CROWN  
60  
* It is recommended that the minute hand  
be set 4 to 5 minutes ahead of the time,  
and then turn it back to the exact minute.  
45  
15  
30  
60  
45  
15  
* If the crown is pulled out when the  
stopwatch is measuring, the stopwatch  
will be automatically reset.  
30  
1. It is necessary to adjust the date at the end of February and 30-day months.  
2. Do not set the date between 9:00 p.m. and 1:00 a.m. Otherwise, the date may not  
change properly.  
Small second hand  
9
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
2) STOPWATCH HAND POSITION ADJUSTMENT  
Press for 2 seconds.  
If the STOPWATCH hands are not in the “0” position, follow the procedure below to set them  
to the “0” position.  
A
B
A
B
* STOPWATCH minute hand turns a full  
circle.  
Press repeatedly to set it to the “0”  
position.  
Press for 2 seconds.  
* STOPWATCH 1/10-second and 1/100-  
second hands turn a full circle.  
A
20  
10  
0
30  
40  
MIN.  
0
5
A
9
6
1
4
8
7
2
3
* The hand moves quickly if Button B is  
kept pressed.  
* STOPWATCH minute hand turns a full  
circle passing the 40-minute marker  
only during the STOPWATCH hand  
position adjustment.  
Press repeatedly to set the STOPWATCH  
hands to the “0” position.  
B
* The hands move quickly if Button B is  
kept pressed.  
B
A
If Button  
is pressed again for 2 seconds, you can go back to the  
adjustment of 1/10- and 1/100-second hands and so on in the following  
order.  
A
STOPWATCH  
minute hand  
STOPWATCH  
second hand  
Press for 2 seconds.  
* STOPWATCH second hand turns a full  
circle.  
STOPWATCH  
1/10- and 1/100-second  
hands  
A
B
Press repeatedly to set it to the “0”  
position.  
After all the adjustments are completed,  
push back in to the normal position in  
accordance with a time signal.  
CROWN  
* The hand moves quickly if Button B is  
kept pressed.  
B
11  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reading the 1/100-second and 1/10-second hands requires extra attention.  
HOW TO USE THE STOPWATCH  
The stopwatch features a 40-minute dial with a retrograde minute hand.  
*
The display illustrated at the left should be read as  
“19,” not "29." When the 1/100-second hand is  
moving toward larger numbers, the 1/10 second  
hand comes close to the next marker, which may  
cause you to wrongly read the hands as "29."  
0
The stopwatch can consecutively measure up to 120 minutes in 1/100-second  
increments. When the measurement reaches 120 minutes, the stopwatch auto-  
matically stops counting.  
1
4
9
6
8
7
2
3
Split time measurement is possible.  
5
After 3 minutes of timing from a start, the STOPWATCH 1/100-second and 1/10-  
second hands remain pointing to the “0” position until the watch is stopped or  
split time measurement is made, at such a time, they move to display the  
measured time. They start to move for a maximum of three minutes after the  
watch is restarted or the split time display is released.  
<Remarks on the STOPWATCH minute hand movement>  
When the minute counting reaches 40 minutes, the STOPWATCH minute hand  
immediately returns and continues counting from 41 minutes onward. The minute  
counting is repeated in the same manner for another rotation, up to 120 minutes,  
at that time the stopwatch automatically stops.  
<How to read the stopwatch hands>  
The time measured is indicated by the four stopwatch hands below.  
The final position of the STOPWATCH minute hand, after completing 120 minutes  
of counting, is illustrated below.  
STOPWATCH 1/100-second hand  
STOPWATCH 1/10-second hand  
STOPWATCH second hand  
0
9
6
1
4
20  
8
7
2
3
10  
0
30  
40  
5
2
10  
0
30  
40  
Before starting to use the stopwatch again, make sure to reset the stopwatch by  
pressing Button B.  
STOPWATCH minute hand  
13  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
<How to reset the stopwatch>  
Accumulated elapsed time measurement  
While the STOPWATCH hands are moving  
1. Press Button A to stop the stopwatch.  
2. Press Button B to reset the stopwatch.  
A
START  
*
A
A
A
B
STOP  
RESTART  
RESET  
STOP  
While the STOPWATCH hands are stopped  
(When the stopwatch is stopped)  
Restart and stop of the stopwatch can be repeated by pressing Button A.  
Split time measurement  
1. Press Button B to reset the stopwatch.  
(When the split time measurement is displayed while the stopwatch is measuring.)  
1. Press Button B to release the split time display and return to the normal display  
2. Press Button A to stop the stopwatch  
A
B
B
A
B
START  
SPLIT  
SPLIT  
STOP  
RESET  
RELEASE  
3. Press Button B to reset the stopwatch  
*
*
Measurement and release of split time can be repeated by pressing Button B.  
(When the split time measurement is displayed and the stopwatch is stopped.)  
1. Press Button B to release the split time display.  
2. Press Button B to reset the stopwatch.  
If the time measured reaches 120 minutes while the split time is being  
displayed, the stopwatch automatically stops counting and releases the split  
time display, showing “40' 00" 00.” Before starting the next measurement,  
make sure to reset the stopwatch by pressing Button B.  
Measurement of two competitors  
Standard measurement  
A
B
A
B
B
2ND COMPETITOR FINISH TIME  
START  
FINISH TIME  
OF 1ST  
RESET  
A
A
B
FINISHES  
OF 2ND  
COMPETITOR  
STOP  
START  
RESET  
COMPETITOR  
15  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DEMONSTRATION FUNCTON OF THE STOP-  
WATCH HAND MOVEMENT  
TACHYMETER  
(for models with tachymeter scale on the dial)  
The demonstration function allows you to view the movement of the four  
STOPWATCH hands.  
To measure the hourly average speed of a vehicle  
Each of the four STOPWATCH hands demonstrates high-speed movements and  
when the demonstration is finished, they return to the original position.  
Ex. 1  
Use the stopwatch to determine  
how many seconds it takes to go  
1 km or 1 mile.  
1
2
How to view the demonstration  
1. Reset the stopwatch.  
STOPWATCH  
second hand:  
40 seconds  
0
9
6
1
4
Tachymeter scale indicated by  
STOPWATCH second hand gives  
the average speed per hour.  
* Refer to "HOW TO USE THE STOPWATCH"  
section of this manual.  
8
7
2
3
2. Press Button B for 2 seconds or longer.  
Tachymeter scale:  
“90”  
“90” (tachymeter scale figure) x 1 (km or mile)  
= 90 km/h or mph  
2
10  
0
30  
40  
B
Tachymeter scale can be used only when the time required is less than 60  
seconds.  
Ex. 2: If the measuring distance is extended to 2 km or miles or shortened to  
0.5 km or miles and STOPWATCH second hand indicates “90” on  
tachymeter scale:  
*
*
After approximately 3 seconds, the demonstration finishes, and the stopwatch is  
reset for the next use.  
“90” (tachymeter scale figure) x 2 (km or mile) = 180 km/h or mph  
“90” (tachymeter scale figure) x 0.5 (km or mile) = 45 km/h or mph  
If either Button A or B is pressed during a demonstration, the demonstration will be  
stopped and the stopwatch will be reset.  
17  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TELEMETER  
(for models with telemeter scale on the dial)  
To measure the hourly rate of operation  
Ex. 1  
The telemeter can provide a rough indication of the distance to the source of light  
and sound.  
The telemeter indicates the distance from your location to an object that emits  
both light and sound. For example, it can indicate the distance to the place where  
lightning struck by measuring the time elapsed after you see a flash of lightning  
until you hear the sound.  
1
Use the stopwatch to measure  
the time required to complete 1  
job.  
STOPWATCH  
second hand:  
20 seconds  
2
Tachymeter scale indicated by  
STOPWATCH second hand gives  
the average number of jobs ac-  
complished per hour.  
A flash of lightning reaches you almost immediately while the sound travels to  
you at a speed of 0.33 km/second. The distance to the source of the light and  
sound can be calculated on the basis of this difference.  
The telemeter scale is so graduated that the sound travels at a speed of 1 km in  
3 seconds.*  
Tachymeter scale:  
“180”  
*
Under the condition of temperature of 20 ºC (68 ºF).  
“180” (tachymeter scale figure) x 1 job  
= 180 jobs/hour  
Ex. 2: If 15 jobs are completed in 20 seconds:  
CAUTION  
“180” (tachymeter scale figure) x 15 jobs = 2700 jobs/hour  
The telemeter provides only a rough indication of the distance to the place where  
lightning struck, and therefore, the indication cannot be used as the guideline to avoid  
the danger of lightning. It should also be noted that the speed of the sound differs  
depending on the temperature of the atmosphere where it travels.  
19  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO USE THE TELEMETER  
BATTERY CHANGE  
Before beginning, check that the stopwatch has been reset.  
The miniature battery which powers your watch should last approxi-  
3
mately 3 years. However, because the battery is inserted at the factory  
to check the function and performance of the watch, its actual life once  
in your possession may be less than the specified period. When the  
battery expires, be sure to replace it as soon as possible to prevent any  
malfunction. For battery replacement, we recommend that you con-  
tact an AUTHORIZED SEIKO DEALER and request SEIKO SR927W  
battery.  
Years  
START  
(Flash of light)  
1
Press button A to start the  
stopwatch as soon as you see  
the light.  
*
If the stopwatch is used for more than 2 hours a day, the battery life  
may be less than the specified period.  
STOP  
2
3
When you hear the sound,  
press button A to stop the stop-  
watch.  
*
After the battery is replaced with a new one, set the time/calendar  
and adjust the stopwatch hand position.  
(Crash of thunder)  
Battery life indicator  
Read the telemeter scale that  
the stopwatch second hand  
points to.  
When the battery nears its end, the small second hand moves at two-second  
intervals instead of normal one-second intervals. In that case, have the battery  
replaced with a new one as soon as possible.  
Approx. 3 km  
*
The watch remains accurate while the small second hand is moving at two-second  
intervals.  
Please note that the stopwatch second hand moves in 1-second increments and does  
not always point exactly to the graduations of the telemeter scale. The telemeter scale  
can be used only when the measured time is less than 60 seconds.  
21  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NECESSARY PROCEDURE AFTER BATTERY  
CHANGE  
After the battery is replaced with a new one, or when an abnormal display appears,  
follow the procedures below to reset the built-in IC. The watch will resume its normal  
operation.  
WARNING  
Do not remove the battery from the watch.  
If it is necessary to take out the battery, keep it out of the reach  
of children. If a child swallows it, consult a doctor immediately.  
<HOW TO RESET THE IC>  
1. Pull out the crown to the second click.  
2. Press Button A and B at the same time.  
CAUTION  
3. Push the crown back in to the normal position and check if the hands move as  
normal.  
Never short-circuit, heat or otherwise tamper with the battery,  
and never expose it to fire. The battery may burst, become very  
hot or catch fire.  
A
The battery is not rechargeable. Never attempt to recharge it,  
as this may cause battery leakage or damage to the battery.  
CROWN  
B
*
Resetting the IC will initialize the watch. Before starting to use the watch, it will be  
necessary to set the time and adjust the STOPWATCH hands to the “0” position.  
Refer to “TIME AND CALENDAR SETTING AND STOPWATCH HAND POSITION  
ADJUSTMENT” section of this manual.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
22  
TROUBLESHOOTING  
Solutions  
Possible causes  
Trouble  
Have the battery replaced with a new one immediately by the retailer from whom the watch was  
purchased.  
The battery has run down.  
The watch stops operating.  
The small second hand moves at two-  
second intervals.  
The battery nears its end.  
Return the watch to a normal temperature so that it works accurately as usual, and then reset the  
time. The watch has been adjusted so that it works accurately when it is worn on your wrist  
under a normal temperature range between 5 ºC and 35 ºC.  
The watch temporarily gains or loses  
time.  
The watch has been left or worn in extremely  
high or low temperatures.  
The watch has been left close to an object with a  
strong magnetic field.  
Correct this condition by moving and keeping the watch away from the magnetic source. If this  
action does not correct the condition, contact the retailer from whom the watch was purchased.  
Reset the time. If the watch does not return to its normal accuracy after resetting the time,  
contact the retailer from whom the watch was purchased.  
You drop the watch, hit it against a hard surface,  
or wear it while playing active sports. The watch  
is exposed to strong vibrations.  
Reset the stopwatch hands to the “0” position. Follow the procedure in "TIME AND CALENDAR  
SETTING AND STOPWATCH HAND POSITION ADJUSTMENT."  
The STOPWATCH hands do not return to  
the “0” position when the stopwatch is reset.  
The watch has been affected by magnetism or  
exposed to strong shocks or vibrations.  
Moisture has entered the watch because the  
gasket has deteriorated.  
Contact the retailer from whom the watch was purchased.  
The inner surface of the glass is clouded.  
The date changes at 12 o’clock noon.  
AM/PM is not properly set.  
Advance the hour hands for 12 hours to correctly set the time and date.  
*
In the event of any other problem, please contact the retailer from whom the watch was  
purchased.  
25  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
1
2
3
4
5
Frequency of crystal oscillator ........ 32,768 Hz (Hz = Hertz … Cycles per second)  
Loss/gain (monthly rate) ................. ± 15 seconds at normal temperature range (5 ºC ~ 35 ºC)  
Operational temperature range ....... –10 ºC ~ +60 ºC  
Driving system ................................ Step motor, 4 pieces  
Display system  
Time/calendar .......................... Hour, minute and small second hands  
Date is displayed in numerals.  
Stopwatch ................................ STOPWATCH 1/100-second hand (0.1 second/ 360 degrees)  
STOPWATCH 1/10-second hand (1 second/ 360 degrees)  
STOPWATCH second hand (60 seconds/ 360 degrees)  
STOPWATCH minute hand (40 minutes/ 240 degrees)  
Battery ............................................ SEIKO SR927W, 1 piece  
Battery life ....................................... Approximately 3 years  
If the stopwatch is used for longer than 2 hours a day, the battery  
life may be shorter than the specified period.  
6
7
8
9
Battery life indicator  
IC (Integrated Circuit) ...................... C-MOS-IC, 1 piece  
*
The specifications are subject to change without prior notice for product improvements.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Quasar Air Conditioner HQ 2121RH User Guide
Ryobi Sander S652D User Guide
Samsung Answering Machine SVMi 8E User Guide
Samsung Camcorder VP DC171WH User Guide
Samsung DVD Player DVD D360K User Guide
Samsung Printer SRP 350PLUSAamp;C User Guide
Sanyo Work Light ECOi User Guide
Scag Power Equipment Lawn Mower Accessory GC STC User Guide
Schumacher Battery Charger SS 51A PE User Guide
Sennheiser Battery Charger l2013 User Guide