OWNER’S INSTRUCTIONS
MANUAL DE INSTRUCCIONES
MANUEL D’UTILISATION
Indoor Unit
Outdoor Unit
US07A5(6)MA
US09A5(6)MAF
US12AA(B)MCF
US18A9(0)RCF
US18A9(0)RCFD
US24A1(2)RC
AS07A5(6)MA
AS09A5(6)MAF
AS12AA(B)MCF
AS18A9(0)RCF
AS18A9(0)RCFD
AS24A1(2)RC
AS24A1(2)RCD
US24A1(2)RCD
Split-type Room Air Conditioner (Cool)
Aire acondicionado doméstico sistema Split (Refrigeración)
Climatiseur de type Séparé (Refroidissement)
E
S
F
DB98-15772A(3)
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
◆
PREPARING YOUR AIR CONDITIONER
◆◆◆Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
◆◆◆View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
◆◆◆Remote Control-Buttons and Display . . . . . . . . . . . . . . . . . . . . 6
◆◆◆Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
◆◆◆Inserting the Remote Control Batteries . . . . . . . . . . . . . . . . . . . 8
◆◆◆Installing the Remote Control Holder . . . . . . . . . . . . . . . . . . . . 8
◆
OPERATING YOUR AIR CONDITIONER
◆◆◆5 Way Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9
◆◆◆Selecting the Automatic Operating Mode . . . . . . . . . . . . . . . . 10
◆◆◆Cooling Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
◆◆◆Changing the Room Temperature Quickly . . . . . . . . . . . . . . . 12
◆◆◆Removing Excess Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . 13
◆◆◆Airing Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
◆◆◆Adjusting the Air Flow Direction Vertically . . . . . . . . . . . . . . . 15
◆◆◆Adjusting the Air Flow Direction Horizontally . . . . . . . . . . . . . 15
◆
◆
PROGRAMMING YOUR AIR CONDITIONER
◆◆◆Setting the On Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
◆◆◆Setting the Off Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
◆◆◆Setting the Sleep Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
RECOMMENDATIONS FOR USE
◆◆◆Operating Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . 19
◆◆◆Temperature and Humidity Ranges . . . . . . . . . . . . . . . . . . . . 20
◆◆◆Cleaning Your Air Conditioner . . . . . . . . . . . . . . . . . . . . . . . . . 21
◆◆◆Solving Common Problems . . . . . . . . . . . . . . . . . . . . . . . . . . 22
◆◆◆Installing a Filter (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
◆
TECHNICAL SPECIFICATIONS
E-3
Download from Www.Somanuals.com. All Manuals Search And Download.
View of the Unit
The design and shape are subject to change according to the model.
Indoor Unit
Air filter
(under the grille)
Air flow blades (outlet)
Air Inlet
Timer indicator
Remote Control Sensor
SAVING indicator
STANDARD indicator
SILENCE indicator
POWER indicator
NATURE indicator
On/Off & 5 Way
selection button
Note
◆ For details on the 5 Way, refer to page 9.
E-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Outdoor Unit US07A5(6)MA
US09A5(6)MAF
Air Inlet(Rear)
Air Outlet
Connection Valve
Outdoor Unit
US12AA(B)MCF
Air Outlet
Air Inlet(Rear)
Connection Valve
Outdoor Unit
US18A9(0)RCF
US18A9(0)RCFD
Air Inlet(Rear)
US24A1(2)RC
Air Outlet
Connection Valve
Outdoor Unit
US24A1(2)RCD
Air Outlet
Air Inlet(Rear)
Connection Valve
E-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Control - Buttons and Display
Remote control
transmission indicator
Mode selection button
(AUTO, COOL, DRY, FAN)
Operating mode
(
AUTO,
COOL,
DRY,
FAN)
Temperature adjustment
buttons
Temperature setting
Turbo mode
Sleep mode
Turbo/Sleep mode
selection button
Fan speed
Fan speed adjustment
button
Air flow direction
Swing button
On Timer setting
On Timer button
Off Timer setting
Off Timer button
Battery discharge indicator
On/Off &
Timer Set/Cancel button
5 Way selection button
E-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
You have just purchased a split type air conditioner and it has been
installed by your installation specialist.
Your Owner’s Instructions contains valuable information on using your
air conditioner. Please take the time to read it as it will help you take full
advantage of the unit’s features.
The booklet is organized as follows.
◆ The following figures are shown on pages from 4 to 6 :
-
-
Indoor and outdoor units
Remote control(buttons and display)
They will help you find the buttons and understand the symbols displayed.
◆ In the manual, you will find a series of step-by-step procedures for each
function available.
The illustrations in the step-by-step procedures use three different symbols:
PRESS
PUSH
HOLD DOWN
E-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Inserting the Remote Control Batteries
You must insert or replace the remote control batteries when :
◆ You purchase the air conditioner
◆ The remote control does not work correctly
Note
◆ Use two AAA, LR03 1.5V batteries.
◆ Do not use old batteries or different kinds of batteries together.
◆ Batteries may be completely discharged after 12 months, even
◆ if they have not actually been used.
Push the battery cover on the rear of the remote control with your thumb
in the direction of the arrow and remove it.
1
2
Insert the two batteries, taking care to respect the polarities :
◆ + on the battery with + on the remote control.
◆ - on the battery with - on the remote control.
Close the cover by sliding it back until it clicks into place.
3
Installing the Remote Control Holder
1
2
Place the remote control holder on the wall.
Fix the remote control holder by tightening the screws.
3
Put the remote control into the holder as shown in the figure.
◆ If you want to install the holder easily, you had better install the holder
on the wooden frame.
E-8
Download from Www.Somanuals.com. All Manuals Search And Download.
5 Way Function
You can select the 5 Way function with operating mode of the air conditioner for
more comfortable circumstances. You can use the 5 Way function with the indoor
unit as well as the remote control. Thus, you can use this function
even though you have lost your remote control.
Using with the indoor unit
1
Press the
mode.
(On/Off) button one time and then select the desired
To obtain a(n)...
Then select...
Normal operating
(STANDARD) mode
Reducing the uncomfortable
temperature gradually
(NATURE) mode
High fan speed
(POWER) mode
(SAVING) mode
(SILENCE) mode
Compressor run time reduced
Fan speed reduces as the temperature
decreases
2
To stop the operating, press the
turn off.
(On/Off) button until all indicators
Note
Even if the air conditioner has been turned on via the
(On/Off)
button on the unit, operations can still be controlled using the
remote control as usual.
Selecting with the Remote Control
To select the 5 Way function with the remote control, press the
one or more times until the desired mode is selected.
button
◆ Each time you press the
button:
Each 5 Way indicator on the indoor unit lights up in order.
E-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Selecting the Automatic Operating Mode
You can start the air conditioner in Automatic mode from your remote
control. In the Automatic mode, the standard temperature and the
optimum fan speed is selected automatically. You can adjust the
standard temperature but not the fan speed.
1
If necessary, press the
(On/Off) button.
Result:
◆ The 5 Way indicator on the indoor unit lights up.
◆ The air conditioner starts up in the mode selected
when the unit was last used.
◆ The indoor unit beeps.
IMPORTANT
The air conditioner is fitted with a protection mechanism to
prevent the unit from being damaged when it is started
immediately after being:
◆ Plugged in
◆ Stopped
lt will start up normally after three minutes.
2
If the
is not displayed at the top of the remote control,
press the
appears.
button on the remote control one or more times until it
Result:
◆ The indoor unit beeps each time you press the
button.
◆ The air conditioner runs in AUTO mode.
Note
You can change modes at any time.
3
To adjust the standard temperature (The air conditioner automatically
set the standard temperature by the current room temperature.),
press the
buttons one or more times.
SET TEMP. SET TEMP.
-4°F -2°F
< When you feel hot >
-
SET TEMP. SET TEMP.
+2°F +4°F
< When you feel chilly >
Standard temperature
E-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Cooling Your Room
You must select the Cool mode if you wish to adjust the:
◆ Cooling temperature
◆ Fan speed when cooling
1
If necessary, press the
(On/Off) button.
Result: The 5 Way indicator on the indoor unit lights up.
◆
◆ The air conditioner starts up in the mode selected
when the unit was last used.
◆ The indoor unit beeps.
IMPORTANT
The air conditioner is fitted with a protection mechanism to
prevent the unit from being damaged when it is started
immediately after being:
◆ Plugged in
◆ Stopped
lt will start up normally after three minutes.
2
If the
is not displayed at the top of the remote control,
press the
appears.
button on the remote control one or more times until it
Result:
◆
◆
The indoor unit beeps each time you press the
The air conditioner runs in COOL mode.
button.
Note
You can change modes at any time.
3
To adjust the temperature, press the
buttons one or more times
until the required temperature is displayed.
Possible temperatures are between 65°F(18°C) and 86°F(30°C)
inclusive.
Result:
◆
Each time you press the
buttons:
- The temperature is adjusted by 1°F
- The indoor unit beeps
◆ The air conditioner starts cooling, provided that the room
temperature is higher than the selected temperature;
the fan will, however, operate.
4
Select the fan speed by pressing the
until the required setting is displayed:
button one or more times
)
Automatic (rotated :
Low
Medium
High
Result:
Each time you press the
button, the indoor unit beeps.
5
To control the direction of the air flow, refer to page 15.
E-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Changing the Room Temperature Quickly
The Turbo cooling function is used to cool your room as quickly as possible.
Example :
You have just come home and find that the room is very
hot. You wish to cool it down as quickly as possible.
The Turbo function operates for 30 minutes with the maximum settings before
returning automatically to the mode and temperature previously selected.
1
If necessary, press the
(On/Off) button.
Result:
◆ The 5 Way indicator on the indoor unit lights up.
◆ The air conditioner starts up in the mode selected when the unit
was last used.
◆ The indoor unit beeps.
2
Press the
Result:
button.
◆ The temperature and fan settings are adjusted automatically.
◆ The air conditioner cools the room as quickly as possible.
◆ After 30 minutes, the air conditioner is reset automatically to the
previous mode, temperature and fan settings.
But, if you press the
button in DRY or FAN mode,
it will change to AUTO mode automatically.
3
If you wish to stop the Turbo function before the end of the 30-minute period,
press the
button one or more times until
or
disappears.
Result:
The air conditioner is reset automatically to the previous mode,
temperature and fan settings.
4
To control the direction of the air flow, refer to page 15.
E-12
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing Excess Humidity
If the atmosphere in your room is very humid or damp, you can
remove excess humidity without lowering the room temperature too
much.
1
If necessary, press the
(On/Off) button.
Result: The 5 Way indicator on the indoor unit lights up.
◆
◆ The air conditioner starts up in the mode selected when
the unit was last used.
◆ The indoor unit beeps.
IMPORTANT
The air conditioner is fitted with a protection mechanism
to prevent the unit from being damaged when it is started
immediately after being:
◆ Plugged in
◆ Stopped
It will start up normally after three minutes.
2
If the
is not displayed at the top of the remote control, press the
button on the remote control one or more times until it appears.
Result:
◆
◆
The indoor unit beeps each time you press the
The air conditioner runs in DRY mode.
button.
Note You can change modes at any time.
3
To adjust the temperature, press the
buttons one or more times
until the required temperature is displayed.
Possible temperatures are between 65°F(18°C) and 86°F(30°C)
inclusive.
Result: ◆ Each time you press the
buttons:
- The temperature is adjusted by 1°F
- The indoor unit beeps
◆ The air conditioner starts removing the excess humidity;
the quantity of air is adjusted automatically.
4
To control the direction of the air flow, refer to page 15.
E-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Airing Your Room
If the atmosphere in your room is stale, you can air the room using
the Fan feature.
1
If necessary, press the
(On/Off) button.
Result:
◆
The 5 Way indicator on the indoor unit lights up.
◆ The air conditioner starts up in the mode selected when
the unit was last used.
◆ The indoor unit beeps.
2
If the
is not displayed at the top of the remote control,
press the
appears.
button on the remote control one or more times until it
Result:
◆
◆
◆
The indoor unit beeps each time you press the
The air conditioner runs in FAN mode.
The temperature is set automatically.
button.
Note
You can change modes at any time.
3
Select the fan speed by pressing the
until the required setting is displayed:
button one or more times
Low
Medium
High
Result: Each time you press the
button, the indoor unit beeps.
4
To control the direction of the air flow, refer to page 15.
E-14
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjusting the Air Flow Direction Vertically
Depending on the position of the indoor unit on the wall of your room,
you can adjust the position of the outer air flow blade on the bottom of
the unit, thus increasing the efficiency of the air conditioner.
1
Press the
button one or more times as required.
Result: The outer blade is adjusted vertically.
RECOMMENDATION
When...
Adjust the blade to face...
Cooling
Upwards.
2
If you want the blade to move up and down automatically when the air
conditioner is operating, press the
button.
Result: The blade move up and down, around the base position set.
3
To stop the blade moving up and down, press the
button again.
Note
If you switch the air conditioner... Then the blade is...
Off
Closed completely.
Set to the initial position powered.
On again
Adjusting the Air Flow Direction Horizontally
There are two sets of inner air flow blades. Just as the outer air flow
blade can be adjusted vertically, the inner blades can be adjusted
horizontally.
1
Adjust each set of inner blades to the required position, by pushing or
pulling them sideways.
◆ The design and shape are subject to
change according to the model.
E-15
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the On Timer
The On Timer enables you to switch on the air conditioner automatically
after a given period of time. You can set the period of time from
30 minutes to 24 hours.
1
To set the operating time, press the
button one or more times until
the required time is displayed. Possible time is between 0.5 hour and
24 hour inclusive.
2
Press the
(Set/Cancel) button to complete the setting.
Result: ◆ The remaining time is displayed.
◆ Blinking of the timer indicator stops.
◆ The selected mode and the temperature on the display
disappear after 10 seconds.
◆ The air conditioner will switch on automatically when the
counter displayed on the remote control reaches the set time
and disappears the On timer setting.
3
To select an operating mode in advance, press the
button until the
desired mode is displayed at the top of the remote control.
Result: ◆ The air conditioner will run in the selected mode when it is
turned on.
To Cancel the On Timer
1
To cancel the On Timer, press the
timer setting disappears.
button one or more times until the
2
Press the
(Set/Cancel) button.
Note
If you want to turn on the air conditioner before the timer reaches
the setting time, press the (On/Off) button.
E-16
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Off Timer
The Off Timer enables you to switch off the air conditioner automatically
after a given period of time. You can set the period of time from
30 minutes to 24 hours.
1
To set the operating time, press the
button one or more times until
the required time is displayed. Possible time is between 0.5 hour and
24 hour inclusive.
2
Press the
(Set/Cancel) button to complete the setting.
Result: ◆ The remaining time is displayed.
◆ Blinking of the timer indicator stops.
◆ The air conditioner will switch off automatically when the
counter displayed on the remote control reaches the set time
and disappears the Off timer setting.
Example If you would like to turn the air conditioner on after 2 hours
and to operate it for 2 hours:
1. Press the
button until ‘2.0 Hr’ is displayed.
2. Press the (Set/Cancel) button.
3. Press the
button until ‘4.0 Hr’ is displayed.
4. Press the (Set/Cancel) button.
Note
You can see or change the setting mode and/or the temperature
by pressing the
Off timer.
button or the
buttons after setting the
To Cancel the Off Timer
1
To cancel the Off Timer, press the
timer setting disappears.
button one or more times until the
2
Press the
(Set/Cancel) button.
Note
If you want to turn off the air conditioner before the timer reaches
the setting time, press the (On/Off) button.
E-17
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Sleep Timer
The Sleep Timer can be used when you are cooling your room to
switch the air conditioner off automatically after a period of six hours.
Note
If you wish to switch the unit off at a specific time, refer to
page 17.
1
2
Make sure that you have selected either COOL mode.
Press the
button one or more times until
appears on the
remote control.
Result: ◆ The indoor unit beeps.
◆ The air conditioner will be controlled as indicated in the
illustrations below.
Cooling The desired temperature is
increased by 2°F every hour.
When it has been increased
by 4°F (after two hours), the
temperature is maintained for
four hours.
To Cancel the Sleep Timer
If you no longer wish to use the Sleep Timer that you have set, you
can cancel it at any time.
Press the
Result:
button.
◆
◆
◆
The indoor unit beeps.
The
The air conditioner operates normally.
is no longer displayed.
E-18
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Recommendations
Here are a few recommendations that you should follow when using
your air conditioner.
Topic
Recommendation
Power failure
If a power failure occurs when the air conditioner
is operating, the unit is switched off.
When the power returns,
◆◆A1◆◆
◆◆A5◆◆
◆◆A9◆◆
◆◆AA◆◆
you must press the (On/Off)
button to restart it.
◆◆A0◆◆
◆◆A2◆◆
◆◆A6◆◆
◆◆AB◆◆
the air conditioner starts up
again automatically
Note
Be sure which model you have purchased because some
air conditioners do not restart automatically.
E-19
Download from Www.Somanuals.com. All Manuals Search And Download.
Temperature and Humidity Ranges
The following table indicates the temperature and humidity ranges
within which the air conditioner can be used.
If the air conditioner is used at... Then...
High temperatures
The automatic protection feature may
be triggered and the air conditioner
stopped.
Low temperatures
A water leak or some other malfunction
may occur if the heat exchanger
freezes.
High humidity levels
Water may condense on and drip
from the surface of the indoor unit if it
is used for long periods.
Mode
Outdoor Temperature
Indoor Temperature Indoor Humidity
Cooling
70°F to 109°F approx.
65°F to 90°F approx.
21°C to 43°C approx.
18°C to 32°C approx. 80% or less
Drying
65°F to 109°F approx.
65°F to 90°F approx.
18°C to 43°C approx.
18°C to 32°C approx.
-
◆◆ If the cooling operation is used at over 92°F/33°C(indoor temperature),
it does not cool as its full capacity.
E-20
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning Your Air Conditioner
To get the best possible use out of your air conditioner, you must
clean it regularly to remove the dust that accumulates on the air filter.
Before cleaning your air conditioner, ensure that you
have switched off the breaker used for the unit.
IMPORTANT
◆◆07/09/12◆◆
1
2
Open the front grille by pulling on the tabs on the lower right and left
sides of the indoor unit.
◆◆07/09/12◆◆
Disassemble the front grille by pulling it forwards.
Note
◆◆18/24◆◆ models are not included.
3
◆◆07/09/12◆◆
Hold the edge of the air filter under the front grille and pull to release them.
◆◆18/24◆◆
Lift out the bottom edge of the air filters and pull down to release them.
4
5
Remove all dust on the air filters with a vacuum cleaner or brush.
◆◆18/24◆◆
Clean the front panel with a damp cloth and mild detergent
(do NOT use benzene, solvents or other chemicals).
6
◆◆18/24◆◆
When you have finished, insert the top part of the filters into their slot and push
down on the bottom edge until they click into place.
Note
◆◆07/09/12◆◆ models are not included.
7
Reassemble the air filters and the front grille.
Hook
Note
◆◆ If you have not used the air conditioner for a long period of time, set the
fan going for three to four hours to dry the inside of the air conditioner
thoroughly.
Body
groove
◆◆ Clean the air filter twice a month. It is recommendable to clean the
air filter more often if your room has heavy dusts.
Front grille
E-21
Download from Www.Somanuals.com. All Manuals Search And Download.
Solving Common Problems
Before contacting the after-sales service, perform the following simple checks.
They may save you the time and expense of an unnecessary call.
Problem
Explanation/Solution
The air conditioner does not
operate at all
◆ Check that the breaker used for the air conditioner is switched on.
◆ Check that the 5 Way indicator on the indoor unit is on;
if necessary press the
(On/Off) button on the remote control.
◆ Check whether the TIMER indicator on the indoor unit is switched on.
If so:
- Wait until the switch-on time is reached and the air conditioner starts
up automatically
- Cancel the timer (see pages 16 and 17 for further details)
The air conditioner does not
operate with the remote control
◆ Check that there are no obstacles between you and the indoor unit.
◆ Check the remote control batteries.
◆ Check that you are close enough to the indoor unit
[23ft(7m) or less].
No beep is heard when you press
◆ Check that you are pointing the remote control at the remote control
sensor in the right of the indoor unit.
the
(On/Off) on the remote
control
◆ Replace the remote control batteries if necessary.
The air conditioner does not cool
◆ Check that the correct operating mode has been selected
(AUTO, COOL).
◆ The room temperature may be too low or too high.
◆ Dust may be blocking the air filter guard; refer to page 21 for cleaning
instructions.
◆ Check that there is no obstacle in front of the outdoor unit.
The fan speed does not change
◆ Check that the operating mode is set to COOL or FAN ;
in the AUTO mode, the fan speed changes automatically and in the
DRY mode, it is set to AUTO.
when you press the
button
The air flow direction does not
change when you press the
button
◆ Check that the air conditioner has been switched on; if necessary,
press the
(On/Off) button on the remote control.
The timer is not correctly triggered
◆ Check that the timer has been programmed correctly; see pages 16
and 17.
Odours are permeated in the room ◆ Air the room.
during air conditioning
E-22
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing a Filter (Option)
The air conditioner can be fitted with a deodorizing and Bio-Pure
filter to remove minute dust particles or odours. The service life of
the filter is approximately three months depending on the time
during which the air conditioner is used.
1
Remove the vinyl packing from the filter.
Note
Do not remove the packing from a deodorizing filter until you
wish to use the filter, as it will lose its properties.
Deodorizing
filter
2
3
Insert the filter in the filter holder and press the three insert tabs until
you hear a click.
Bio-Pure Filter
Open the front grille by pulling on the tabs on the lower right and left
sides of the indoor unit.
4
Take out the existing filter and replace it with the new one.
E-23
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Specifications
MODEL
AS07A5(6)MA
AS09A5(6)MAF
AS12AA(B)MCF
Capacity Cooling
SEER
Btu/h
7500
10.0
9000
11500
Performance
Ratings
10.0
10.0
Moisture Removal
Air FLOW(Cooling, HIGH)
Sound Rating-Outdoor
Power source
Pts/h
CFM
dB
3
4
2.5
214
230
51
261
50
55
208-230V~, 60Hz
5.4
Electrical
Data
115V~, 60Hz
6.4
115V~, 60Hz
8.1
A
Min.Ampacity
W
Cooling Watts
680
950
1230
Flare
Connections
Flare
Flare
Refrigeration
Lines
1
1
1
Liquid Line O. D.
Suction Line O.D.
Factory Pre-charge
Max. Line length
Max. Height Difference
inch(mm)
inch(mm)
ft(m)
4 (6.35)
4 (6.35)
4 (6.35)
3
3
1
8 (9.52)
8 (9.52)
2 (12.70)
16 21 (5.0 )
49 41 (15.0 )
24 43 (7.5)
49 41 (15.0 )
24 43 (7.5)
49 41 (15.0 )
ft(m)
ft(m)
23(7.0)
23(7.0)
23(7.0)
AS07A5(6)MA
AS09A5(6)MAF
AS12AA(B)MCF
Dimensions
& Weight
INDOOR UNIT
31 18
912 621
31 18
921 621
31 18
921 621
x
x
x
x
x
x
inch(mm)
W x H x D
Net Weight
(790 x 245 x 165)
(790 x 245 x 165)
(790 x 245 x 165)
Ibs(kg)
21.2(9.6)
21.2(9.6)
21.2(9.6)
OUTDOOR UNIT
W x H x D
Net Weight
◆◆Standard rating conditions Cooling
US07A5(6)MA
US09A5(6)MAF
US12AA(B)MCF
1
1
26 x 19 12 94
26 x 19 12 94
x
3
x
x
29 x
20 4
9
inch(mm)
Ibs(kg)
(660 x 497 x 235)
60.7(27)
(660 x 497 x 235)
61.7(27.4)
(740 x 530 x 230)
71.5(32)
Indoor
Outdoor
DB
80
WB
67
DB
WB
75
95
°F
26.7
19.4
35.0
23.9
°C
E-24
Download from Www.Somanuals.com. All Manuals Search And Download.
MODEL
AS18A9(0)RCF/AS18A9(0)RCFD
AS24A1(2)RC/AS24A1(2)RCD
Capacity Cooling
SEER
Btu/h
18000
10.0
23500
10.0
Performance
Ratings
Moisture Removal
Air FLOW(Cooling, HIGH)
Sound Rating-Outdoor
Power source
Pts/h
CFM
dB
4.9
5.4
456
477
57
208-230V~, 60Hz
8.0
59
208-230V~, 60Hz
10.5
Electrical
Data
A
Min.Ampacity
W
Cooling Watts
1770
2350
Connections
Flare
Flare
Refrigeration
Lines
1
1
Liquid Line O. D.
Suction Line O.D.
Factory Pre-charge
Max. Line length
Max. Height Difference
inch(mm)
inch(mm)
ft(m)
4 (6.35)
4 (6.35)
1
5
8 (15.88)
2 (12.70)
24 43 (7.5)
49 41 (15.0 )
23(7.0)
16 21 (5.0)
65 21 (20.0)
ft(m)
1 (8.0 )
26 4
ft(m)
AS18A9(0)RCF/AS18A9(0)RCFD AS24A1(2)RC/AS24A1(2)RCD
Dimensions
& Weight
INDOOR UNIT
42 12 11 x 8
x
42 12 11 x 8
x
inch(mm)
W x H x D
Net Weight
(1080 x 275 x 204)
(1080 x 275 x 204)
Ibs(kg)
29.7(13.4)
29.7(13.4)
OUTDOOR UNIT
US18A9(0)RCF/US18A9(0)RCFD US24A1(2)RC/US24A1(2)RCD
3
x 24 8 x 12 58
34 85 x 25 81 x12 14
31
W x H x D
Net Weight
inch(mm)
Ibs(kg)
(880 x 638 x 310)
(787 x 620 x 320)
98.1(44)
138.9(62)
E-25
Download from Www.Somanuals.com. All Manuals Search And Download.
THIS AIR CONDITIONER IS MANUFACTURED BY:
ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR:
CE CLIMATISEUR EST FABRIQUE PAR:
ELECTRONICS
Printed in Korea
Download from Www.Somanuals.com. All Manuals Search And Download.
|