Samsung Air Conditioner AS07A56MA User Guide

OWNER’S INSTRUCTIONS  
MANUAL DE INSTRUCCIONES  
MANUEL D’UTILISATION  
Indoor Unit  
Outdoor Unit  
US07A5(6)MA  
US09A5(6)MAF  
US12AA(B)MCF  
US18A9(0)RCF  
US18A9(0)RCFD  
US24A1(2)RC  
AS07A5(6)MA  
AS09A5(6)MAF  
AS12AA(B)MCF  
AS18A9(0)RCF  
AS18A9(0)RCFD  
AS24A1(2)RC  
AS24A1(2)RCD  
US24A1(2)RCD  
Split-type Room Air Conditioner (Cool)  
Aire acondicionado doméstico sistema Split (Refrigeración)  
Climatiseur de type Séparé (Refroidissement)  
E
S
F
DB98-15772A(3)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
PREPARING YOUR AIR CONDITIONER  
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Remote Control-Buttons and Display . . . . . . . . . . . . . . . . . . . . 6  
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Inserting the Remote Control Batteries . . . . . . . . . . . . . . . . . . . 8  
Installing the Remote Control Holder . . . . . . . . . . . . . . . . . . . . 8  
OPERATING YOUR AIR CONDITIONER  
5 Way Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
9
Selecting the Automatic Operating Mode . . . . . . . . . . . . . . . . 10  
Cooling Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
Changing the Room Temperature Quickly . . . . . . . . . . . . . . . 12  
Removing Excess Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
Airing Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
Adjusting the Air Flow Direction Vertically . . . . . . . . . . . . . . . 15  
Adjusting the Air Flow Direction Horizontally . . . . . . . . . . . . . 15  
PROGRAMMING YOUR AIR CONDITIONER  
Setting the On Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
Setting the Off Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17  
Setting the Sleep Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
RECOMMENDATIONS FOR USE  
Operating Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . 19  
Temperature and Humidity Ranges . . . . . . . . . . . . . . . . . . . . 20  
Cleaning Your Air Conditioner . . . . . . . . . . . . . . . . . . . . . . . . . 21  
Solving Common Problems . . . . . . . . . . . . . . . . . . . . . . . . . . 22  
Installing a Filter (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23  
TECHNICAL SPECIFICATIONS  
E-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
View of the Unit  
The design and shape are subject to change according to the model.  
Indoor Unit  
Air filter  
(under the grille)  
Air flow blades (outlet)  
Air Inlet  
Timer indicator  
Remote Control Sensor  
SAVING indicator  
STANDARD indicator  
SILENCE indicator  
POWER indicator  
NATURE indicator  
On/Off & 5 Way  
selection button  
Note  
For details on the 5 Way, refer to page 9.  
E-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Outdoor Unit US07A5(6)MA  
US09A5(6)MAF  
Air Inlet(Rear)  
Air Outlet  
Connection Valve  
Outdoor Unit  
US12AA(B)MCF  
Air Outlet  
Air Inlet(Rear)  
Connection Valve  
Outdoor Unit  
US18A9(0)RCF  
US18A9(0)RCFD  
Air Inlet(Rear)  
US24A1(2)RC  
Air Outlet  
Connection Valve  
Outdoor Unit  
US24A1(2)RCD  
Air Outlet  
Air Inlet(Rear)  
Connection Valve  
E-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control - Buttons and Display  
Remote control  
transmission indicator  
Mode selection button  
(AUTO, COOL, DRY, FAN)  
Operating mode  
(
AUTO,  
COOL,  
DRY,  
FAN)  
Temperature adjustment  
buttons  
Temperature setting  
Turbo mode  
Sleep mode  
Turbo/Sleep mode  
selection button  
Fan speed  
Fan speed adjustment  
button  
Air flow direction  
Swing button  
On Timer setting  
On Timer button  
Off Timer setting  
Off Timer button  
Battery discharge indicator  
On/Off &  
Timer Set/Cancel button  
5 Way selection button  
E-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
You have just purchased a split type air conditioner and it has been  
installed by your installation specialist.  
Your Owner’s Instructions contains valuable information on using your  
air conditioner. Please take the time to read it as it will help you take full  
advantage of the unit’s features.  
The booklet is organized as follows.  
The following figures are shown on pages from 4 to 6 :  
-
-
Indoor and outdoor units  
Remote control(buttons and display)  
They will help you find the buttons and understand the symbols displayed.  
In the manual, you will find a series of step-by-step procedures for each  
function available.  
The illustrations in the step-by-step procedures use three different symbols:  
PRESS  
PUSH  
HOLD DOWN  
E-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Inserting the Remote Control Batteries  
You must insert or replace the remote control batteries when :  
You purchase the air conditioner  
The remote control does not work correctly  
Note  
Use two AAA, LR03 1.5V batteries.  
Do not use old batteries or different kinds of batteries together.  
Batteries may be completely discharged after 12 months, even  
if they have not actually been used.  
Push the battery cover on the rear of the remote control with your thumb  
in the direction of the arrow and remove it.  
1
2
Insert the two batteries, taking care to respect the polarities :  
+ on the battery with + on the remote control.  
- on the battery with - on the remote control.  
Close the cover by sliding it back until it clicks into place.  
3
Installing the Remote Control Holder  
1
2
Place the remote control holder on the wall.  
Fix the remote control holder by tightening the screws.  
3
Put the remote control into the holder as shown in the figure.  
If you want to install the holder easily, you had better install the holder  
on the wooden frame.  
E-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 Way Function  
You can select the 5 Way function with operating mode of the air conditioner for  
more comfortable circumstances. You can use the 5 Way function with the indoor  
unit as well as the remote control. Thus, you can use this function  
even though you have lost your remote control.  
Using with the indoor unit  
1
Press the  
mode.  
(On/Off) button one time and then select the desired  
To obtain a(n)...  
Then select...  
Normal operating  
(STANDARD) mode  
Reducing the uncomfortable  
temperature gradually  
(NATURE) mode  
High fan speed  
(POWER) mode  
(SAVING) mode  
(SILENCE) mode  
Compressor run time reduced  
Fan speed reduces as the temperature  
decreases  
2
To stop the operating, press the  
turn off.  
(On/Off) button until all indicators  
Note  
Even if the air conditioner has been turned on via the  
(On/Off)  
button on the unit, operations can still be controlled using the  
remote control as usual.  
Selecting with the Remote Control  
To select the 5 Way function with the remote control, press the  
one or more times until the desired mode is selected.  
button  
Each time you press the  
button:  
Each 5 Way indicator on the indoor unit lights up in order.  
E-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Selecting the Automatic Operating Mode  
You can start the air conditioner in Automatic mode from your remote  
control. In the Automatic mode, the standard temperature and the  
optimum fan speed is selected automatically. You can adjust the  
standard temperature but not the fan speed.  
1
If necessary, press the  
(On/Off) button.  
Result:  
The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected  
when the unit was last used.  
The indoor unit beeps.  
IMPORTANT  
The air conditioner is fitted with a protection mechanism to  
prevent the unit from being damaged when it is started  
immediately after being:  
Plugged in  
Stopped  
lt will start up normally after three minutes.  
2
If the  
is not displayed at the top of the remote control,  
press the  
appears.  
button on the remote control one or more times until it  
Result:  
The indoor unit beeps each time you press the  
button.  
The air conditioner runs in AUTO mode.  
Note  
You can change modes at any time.  
3
To adjust the standard temperature (The air conditioner automatically  
set the standard temperature by the current room temperature.),  
press the  
buttons one or more times.  
SET TEMP. SET TEMP.  
-4°F -2°F  
< When you feel hot >  
-
SET TEMP. SET TEMP.  
+2°F +4°F  
< When you feel chilly >  
Standard temperature  
E-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cooling Your Room  
You must select the Cool mode if you wish to adjust the:  
Cooling temperature  
Fan speed when cooling  
1
If necessary, press the  
(On/Off) button.  
Result: The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected  
when the unit was last used.  
The indoor unit beeps.  
IMPORTANT  
The air conditioner is fitted with a protection mechanism to  
prevent the unit from being damaged when it is started  
immediately after being:  
Plugged in  
Stopped  
lt will start up normally after three minutes.  
2
If the  
is not displayed at the top of the remote control,  
press the  
appears.  
button on the remote control one or more times until it  
Result:  
The indoor unit beeps each time you press the  
The air conditioner runs in COOL mode.  
button.  
Note  
You can change modes at any time.  
3
To adjust the temperature, press the  
buttons one or more times  
until the required temperature is displayed.  
Possible temperatures are between 65°F(18°C) and 86°F(30°C)  
inclusive.  
Result:  
Each time you press the  
buttons:  
- The temperature is adjusted by 1°F  
- The indoor unit beeps  
The air conditioner starts cooling, provided that the room  
temperature is higher than the selected temperature;  
the fan will, however, operate.  
4
Select the fan speed by pressing the  
until the required setting is displayed:  
button one or more times  
)
Automatic (rotated :  
Low  
Medium  
High  
Result:  
Each time you press the  
button, the indoor unit beeps.  
5
To control the direction of the air flow, refer to page 15.  
E-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Changing the Room Temperature Quickly  
The Turbo cooling function is used to cool your room as quickly as possible.  
Example :  
You have just come home and find that the room is very  
hot. You wish to cool it down as quickly as possible.  
The Turbo function operates for 30 minutes with the maximum settings before  
returning automatically to the mode and temperature previously selected.  
1
If necessary, press the  
(On/Off) button.  
Result:  
The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected when the unit  
was last used.  
The indoor unit beeps.  
2
Press the  
Result:  
button.  
The temperature and fan settings are adjusted automatically.  
The air conditioner cools the room as quickly as possible.  
After 30 minutes, the air conditioner is reset automatically to the  
previous mode, temperature and fan settings.  
But, if you press the  
button in DRY or FAN mode,  
it will change to AUTO mode automatically.  
3
If you wish to stop the Turbo function before the end of the 30-minute period,  
press the  
button one or more times until  
or  
disappears.  
Result:  
The air conditioner is reset automatically to the previous mode,  
temperature and fan settings.  
4
To control the direction of the air flow, refer to page 15.  
E-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Removing Excess Humidity  
If the atmosphere in your room is very humid or damp, you can  
remove excess humidity without lowering the room temperature too  
much.  
1
If necessary, press the  
(On/Off) button.  
Result: The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected when  
the unit was last used.  
The indoor unit beeps.  
IMPORTANT  
The air conditioner is fitted with a protection mechanism  
to prevent the unit from being damaged when it is started  
immediately after being:  
Plugged in  
Stopped  
It will start up normally after three minutes.  
2
If the  
is not displayed at the top of the remote control, press the  
button on the remote control one or more times until it appears.  
Result:  
The indoor unit beeps each time you press the  
The air conditioner runs in DRY mode.  
button.  
Note You can change modes at any time.  
3
To adjust the temperature, press the  
buttons one or more times  
until the required temperature is displayed.  
Possible temperatures are between 65°F(18°C) and 86°F(30°C)  
inclusive.  
Result: Each time you press the  
buttons:  
- The temperature is adjusted by 1°F  
- The indoor unit beeps  
The air conditioner starts removing the excess humidity;  
the quantity of air is adjusted automatically.  
4
To control the direction of the air flow, refer to page 15.  
E-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Airing Your Room  
If the atmosphere in your room is stale, you can air the room using  
the Fan feature.  
1
If necessary, press the  
(On/Off) button.  
Result:  
The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected when  
the unit was last used.  
The indoor unit beeps.  
2
If the  
is not displayed at the top of the remote control,  
press the  
appears.  
button on the remote control one or more times until it  
Result:  
The indoor unit beeps each time you press the  
The air conditioner runs in FAN mode.  
The temperature is set automatically.  
button.  
Note  
You can change modes at any time.  
3
Select the fan speed by pressing the  
until the required setting is displayed:  
button one or more times  
Low  
Medium  
High  
Result: Each time you press the  
button, the indoor unit beeps.  
4
To control the direction of the air flow, refer to page 15.  
E-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Adjusting the Air Flow Direction Vertically  
Depending on the position of the indoor unit on the wall of your room,  
you can adjust the position of the outer air flow blade on the bottom of  
the unit, thus increasing the efficiency of the air conditioner.  
1
Press the  
button one or more times as required.  
Result: The outer blade is adjusted vertically.  
RECOMMENDATION  
When...  
Adjust the blade to face...  
Cooling  
Upwards.  
2
If you want the blade to move up and down automatically when the air  
conditioner is operating, press the  
button.  
Result: The blade move up and down, around the base position set.  
3
To stop the blade moving up and down, press the  
button again.  
Note  
If you switch the air conditioner... Then the blade is...  
Off  
Closed completely.  
Set to the initial position powered.  
On again  
Adjusting the Air Flow Direction Horizontally  
There are two sets of inner air flow blades. Just as the outer air flow  
blade can be adjusted vertically, the inner blades can be adjusted  
horizontally.  
1
Adjust each set of inner blades to the required position, by pushing or  
pulling them sideways.  
The design and shape are subject to  
change according to the model.  
E-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting the On Timer  
The On Timer enables you to switch on the air conditioner automatically  
after a given period of time. You can set the period of time from  
30 minutes to 24 hours.  
1
To set the operating time, press the  
button one or more times until  
the required time is displayed. Possible time is between 0.5 hour and  
24 hour inclusive.  
2
Press the  
(Set/Cancel) button to complete the setting.  
Result: The remaining time is displayed.  
Blinking of the timer indicator stops.  
The selected mode and the temperature on the display  
disappear after 10 seconds.  
The air conditioner will switch on automatically when the  
counter displayed on the remote control reaches the set time  
and disappears the On timer setting.  
3
To select an operating mode in advance, press the  
button until the  
desired mode is displayed at the top of the remote control.  
Result: The air conditioner will run in the selected mode when it is  
turned on.  
To Cancel the On Timer  
1
To cancel the On Timer, press the  
timer setting disappears.  
button one or more times until the  
2
Press the  
(Set/Cancel) button.  
Note  
If you want to turn on the air conditioner before the timer reaches  
the setting time, press the (On/Off) button.  
E-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting the Off Timer  
The Off Timer enables you to switch off the air conditioner automatically  
after a given period of time. You can set the period of time from  
30 minutes to 24 hours.  
1
To set the operating time, press the  
button one or more times until  
the required time is displayed. Possible time is between 0.5 hour and  
24 hour inclusive.  
2
Press the  
(Set/Cancel) button to complete the setting.  
Result: The remaining time is displayed.  
Blinking of the timer indicator stops.  
The air conditioner will switch off automatically when the  
counter displayed on the remote control reaches the set time  
and disappears the Off timer setting.  
Example If you would like to turn the air conditioner on after 2 hours  
and to operate it for 2 hours:  
1. Press the  
button until ‘2.0 Hr’ is displayed.  
2. Press the (Set/Cancel) button.  
3. Press the  
button until ‘4.0 Hr’ is displayed.  
4. Press the (Set/Cancel) button.  
Note  
You can see or change the setting mode and/or the temperature  
by pressing the  
Off timer.  
button or the  
buttons after setting the  
To Cancel the Off Timer  
1
To cancel the Off Timer, press the  
timer setting disappears.  
button one or more times until the  
2
Press the  
(Set/Cancel) button.  
Note  
If you want to turn off the air conditioner before the timer reaches  
the setting time, press the (On/Off) button.  
E-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting the Sleep Timer  
The Sleep Timer can be used when you are cooling your room to  
switch the air conditioner off automatically after a period of six hours.  
Note  
If you wish to switch the unit off at a specific time, refer to  
page 17.  
1
2
Make sure that you have selected either COOL mode.  
Press the  
button one or more times until  
appears on the  
remote control.  
Result: The indoor unit beeps.  
The air conditioner will be controlled as indicated in the  
illustrations below.  
Cooling The desired temperature is  
increased by 2°F every hour.  
When it has been increased  
by 4°F (after two hours), the  
temperature is maintained for  
four hours.  
To Cancel the Sleep Timer  
If you no longer wish to use the Sleep Timer that you have set, you  
can cancel it at any time.  
Press the  
Result:  
button.  
The indoor unit beeps.  
The  
The air conditioner operates normally.  
is no longer displayed.  
E-18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Recommendations  
Here are a few recommendations that you should follow when using  
your air conditioner.  
Topic  
Recommendation  
Power failure  
If a power failure occurs when the air conditioner  
is operating, the unit is switched off.  
When the power returns,  
◆◆A1◆  
◆◆A5◆  
◆◆A9◆  
◆◆AA◆  
you must press the (On/Off)  
button to restart it.  
◆◆A0◆  
◆◆A2◆  
◆◆A6◆  
◆◆AB◆  
the air conditioner starts up  
again automatically  
Note  
Be sure which model you have purchased because some  
air conditioners do not restart automatically.  
E-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Temperature and Humidity Ranges  
The following table indicates the temperature and humidity ranges  
within which the air conditioner can be used.  
If the air conditioner is used at... Then...  
High temperatures  
The automatic protection feature may  
be triggered and the air conditioner  
stopped.  
Low temperatures  
A water leak or some other malfunction  
may occur if the heat exchanger  
freezes.  
High humidity levels  
Water may condense on and drip  
from the surface of the indoor unit if it  
is used for long periods.  
Mode  
Outdoor Temperature  
Indoor Temperature Indoor Humidity  
Cooling  
70°F to 109°F approx.  
65°F to 90°F approx.  
21°C to 43°C approx.  
18°C to 32°C approx. 80% or less  
Drying  
65°F to 109°F approx.  
65°F to 90°F approx.  
18°C to 43°C approx.  
18°C to 32°C approx.  
-
◆◆ If the cooling operation is used at over 92°F/33°C(indoor temperature),  
it does not cool as its full capacity.  
E-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleaning Your Air Conditioner  
To get the best possible use out of your air conditioner, you must  
clean it regularly to remove the dust that accumulates on the air filter.  
Before cleaning your air conditioner, ensure that you  
have switched off the breaker used for the unit.  
IMPORTANT  
◆◆07/09/12◆  
1
2
Open the front grille by pulling on the tabs on the lower right and left  
sides of the indoor unit.  
◆◆07/09/12◆  
Disassemble the front grille by pulling it forwards.  
Note  
◆◆18/24models are not included.  
3
◆◆07/09/12◆  
Hold the edge of the air filter under the front grille and pull to release them.  
◆◆18/24◆  
Lift out the bottom edge of the air filters and pull down to release them.  
4
5
Remove all dust on the air filters with a vacuum cleaner or brush.  
◆◆18/24◆  
Clean the front panel with a damp cloth and mild detergent  
(do NOT use benzene, solvents or other chemicals).  
6
◆◆18/24◆  
When you have finished, insert the top part of the filters into their slot and push  
down on the bottom edge until they click into place.  
Note  
◆◆07/09/12models are not included.  
7
Reassemble the air filters and the front grille.  
Hook  
Note  
◆◆ If you have not used the air conditioner for a long period of time, set the  
fan going for three to four hours to dry the inside of the air conditioner  
thoroughly.  
Body  
groove  
◆◆ Clean the air filter twice a month. It is recommendable to clean the  
air filter more often if your room has heavy dusts.  
Front grille  
E-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Solving Common Problems  
Before contacting the after-sales service, perform the following simple checks.  
They may save you the time and expense of an unnecessary call.  
Problem  
Explanation/Solution  
The air conditioner does not  
operate at all  
Check that the breaker used for the air conditioner is switched on.  
Check that the 5 Way indicator on the indoor unit is on;  
if necessary press the  
(On/Off) button on the remote control.  
Check whether the TIMER indicator on the indoor unit is switched on.  
If so:  
- Wait until the switch-on time is reached and the air conditioner starts  
up automatically  
- Cancel the timer (see pages 16 and 17 for further details)  
The air conditioner does not  
operate with the remote control  
Check that there are no obstacles between you and the indoor unit.  
Check the remote control batteries.  
Check that you are close enough to the indoor unit  
[23ft(7m) or less].  
No beep is heard when you press  
Check that you are pointing the remote control at the remote control  
sensor in the right of the indoor unit.  
the  
(On/Off) on the remote  
control  
Replace the remote control batteries if necessary.  
The air conditioner does not cool  
Check that the correct operating mode has been selected  
(AUTO, COOL).  
The room temperature may be too low or too high.  
Dust may be blocking the air filter guard; refer to page 21 for cleaning  
instructions.  
Check that there is no obstacle in front of the outdoor unit.  
The fan speed does not change  
Check that the operating mode is set to COOL or FAN ;  
in the AUTO mode, the fan speed changes automatically and in the  
DRY mode, it is set to AUTO.  
when you press the  
button  
The air flow direction does not  
change when you press the  
button  
Check that the air conditioner has been switched on; if necessary,  
press the  
(On/Off) button on the remote control.  
The timer is not correctly triggered  
Check that the timer has been programmed correctly; see pages 16  
and 17.  
Odours are permeated in the room Air the room.  
during air conditioning  
E-22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Filter (Option)  
The air conditioner can be fitted with a deodorizing and Bio-Pure  
filter to remove minute dust particles or odours. The service life of  
the filter is approximately three months depending on the time  
during which the air conditioner is used.  
1
Remove the vinyl packing from the filter.  
Note  
Do not remove the packing from a deodorizing filter until you  
wish to use the filter, as it will lose its properties.  
Deodorizing  
filter  
2
3
Insert the filter in the filter holder and press the three insert tabs until  
you hear a click.  
Bio-Pure Filter  
Open the front grille by pulling on the tabs on the lower right and left  
sides of the indoor unit.  
4
Take out the existing filter and replace it with the new one.  
E-23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Specifications  
MODEL  
AS07A5(6)MA  
AS09A5(6)MAF  
AS12AA(B)MCF  
Capacity Cooling  
SEER  
Btu/h  
7500  
10.0  
9000  
11500  
Performance  
Ratings  
10.0  
10.0  
Moisture Removal  
Air FLOW(Cooling, HIGH)  
Sound Rating-Outdoor  
Power source  
Pts/h  
CFM  
dB  
3
4
2.5  
214  
230  
51  
261  
50  
55  
208-230V~, 60Hz  
5.4  
Electrical  
Data  
115V~, 60Hz  
6.4  
115V~, 60Hz  
8.1  
A
Min.Ampacity  
W
Cooling Watts  
680  
950  
1230  
Flare  
Connections  
Flare  
Flare  
Refrigeration  
Lines  
1
1
1
Liquid Line O. D.  
Suction Line O.D.  
Factory Pre-charge  
Max. Line length  
Max. Height Difference  
inch(mm)  
inch(mm)  
ft(m)  
4 (6.35)  
4 (6.35)  
4 (6.35)  
3
3
1
8 (9.52)  
8 (9.52)  
2 (12.70)  
16 21 (5.0 )  
49 41 (15.0 )  
24 43 (7.5)  
49 41 (15.0 )  
24 43 (7.5)  
49 41 (15.0 )  
ft(m)  
ft(m)  
23(7.0)  
23(7.0)  
23(7.0)  
AS07A5(6)MA  
AS09A5(6)MAF  
AS12AA(B)MCF  
Dimensions  
& Weight  
INDOOR UNIT  
31 18  
912 621  
31 18  
921 621  
31 18  
921 621  
x
x
x
x
x
x
inch(mm)  
W x H x D  
Net Weight  
(790 x 245 x 165)  
(790 x 245 x 165)  
(790 x 245 x 165)  
Ibs(kg)  
21.2(9.6)  
21.2(9.6)  
21.2(9.6)  
OUTDOOR UNIT  
W x H x D  
Net Weight  
Standard rating conditions Cooling  
US07A5(6)MA  
US09A5(6)MAF  
US12AA(B)MCF  
1
1
26 x 19 12 94  
26 x 19 12 94  
x
3
x
x
29 x  
20 4  
9
inch(mm)  
Ibs(kg)  
(660 x 497 x 235)  
60.7(27)  
(660 x 497 x 235)  
61.7(27.4)  
(740 x 530 x 230)  
71.5(32)  
Indoor  
Outdoor  
DB  
80  
WB  
67  
DB  
WB  
75  
95  
°F  
26.7  
19.4  
35.0  
23.9  
°C  
E-24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL  
AS18A9(0)RCF/AS18A9(0)RCFD  
AS24A1(2)RC/AS24A1(2)RCD  
Capacity Cooling  
SEER  
Btu/h  
18000  
10.0  
23500  
10.0  
Performance  
Ratings  
Moisture Removal  
Air FLOW(Cooling, HIGH)  
Sound Rating-Outdoor  
Power source  
Pts/h  
CFM  
dB  
4.9  
5.4  
456  
477  
57  
208-230V~, 60Hz  
8.0  
59  
208-230V~, 60Hz  
10.5  
Electrical  
Data  
A
Min.Ampacity  
W
Cooling Watts  
1770  
2350  
Connections  
Flare  
Flare  
Refrigeration  
Lines  
1
1
Liquid Line O. D.  
Suction Line O.D.  
Factory Pre-charge  
Max. Line length  
Max. Height Difference  
inch(mm)  
inch(mm)  
ft(m)  
4 (6.35)  
4 (6.35)  
1
5
8 (15.88)  
2 (12.70)  
24 43 (7.5)  
49 41 (15.0 )  
23(7.0)  
16 21 (5.0)  
65 21 (20.0)  
ft(m)  
1 (8.0 )  
26 4  
ft(m)  
AS18A9(0)RCF/AS18A9(0)RCFD AS24A1(2)RC/AS24A1(2)RCD  
Dimensions  
& Weight  
INDOOR UNIT  
42 12 11 x 8  
x
42 12 11 x 8  
x
inch(mm)  
W x H x D  
Net Weight  
(1080 x 275 x 204)  
(1080 x 275 x 204)  
Ibs(kg)  
29.7(13.4)  
29.7(13.4)  
OUTDOOR UNIT  
US18A9(0)RCF/US18A9(0)RCFD US24A1(2)RC/US24A1(2)RCD  
3
x 24 8 x 12 58  
34 85 x 25 81 x12 14  
31  
W x H x D  
Net Weight  
inch(mm)  
Ibs(kg)  
(880 x 638 x 310)  
(787 x 620 x 320)  
98.1(44)  
138.9(62)  
E-25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
THIS AIR CONDITIONER IS MANUFACTURED BY:  
ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR:  
CE CLIMATISEUR EST FABRIQUE PAR:  
ELECTRONICS  
Printed in Korea  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Radio Shack Speaker 40 4091 User Guide
Radio Shack Telephone ET 205 User Guide
Regency Indoor Fireplace U32 LP5 User Guide
Rival Rice Cooker FSD201 User Guide
Roland Musical Instrument RT 10K User Guide
Samsung All in One Printer ML 2245 User Guide
Sanyo Air Conditioner 18XLS52 User Guide
Sanyo Battery Charger KR 1000SCL User Guide
Savin All in One Printer SDC306A User Guide
Scag Power Equipment Lawn Mower Accessory GC STC User Guide