ComPoint™ ISH1 Hub
The music lover’s intercom solution
Instruction Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT FEATURES
2
3
DOORBELL CHIME
GAIN
PROGRAM OPTIONS
0=DOWN / 1=UP
NEWMARKET, NH USA
15VDC
ISH1
DOOR BELL CHIME
HUB ID
MIN
MAX
1
8
4
DS1
DS2
3.5A MAX
SWITCH 1-3
HUB 1 = 000
HUB 2 = 001
HUB 3 = 010
HUB 4 = 011
HUB 5 = 100
HUB 6 = 101
NONE = 000
CHIME 1 = 001
CHIME 2 = 010
CHIME 3 = 011
CHIME 4 = 100
CHIME 5 = 101
CHIME 6 = 110
CHIME 7 = 111
1-3 = DOOR 1 CHIME
SWITCH 4 = CHIME VOLUME
UP = 50% MAX KEYPAD OUTPUT
DOWN = KEYPAD ADJUSTABLE
5-7 = DOOR 2 CHIME
8 = NOT USED
#4
RUN
UPDATE
1
3
5
DOOR 1
LINK
IN
OUT
5
2
4
6
DOOR 2
FIRMWARE
UPDATE PORT
MADE IN CHINA
7
6
1
2
3
4
5
6
POWER INPUT – For connecting model ISPS power
adapter
LINK PORTS – For connecting multiple ISH1 hubs
FIRMWARE UPDATE PORT – For updating device
firmware from a connected computer
DOORBELL CHIME GAIN CONTROL – For adjusting
overall chime volume
7
8
DOOR STATION PORTS – For connecting ISK3 door
stations
DOORBELL CHIME SWITCHES – For assigning
chimes to door 1 and door 2
ZONE PORTS – For connecting ISK1 or ISK2 zone
keypads
HUB ID SWITCHES – For assigning hub ID number
Download from Www.Somanuals.com. All Manuals Search And Download.
3
INSTALLATION
Product summary
Wiring and connections
As the central controller for the ComPoint™ system,
the ISH1 Hub performs all communications routing.
It addresses the keypads and door stations accord-
ing to the ports they’re connected to.
The ISH1 Hub connects to the keypads and door
stations with CAT-5 cable. The length limit for the
CAT-5 cable is 250 feet (76 m).
Run CAT-5 from the hub location to every keypad
and door station location. If you are installing
optional ISDR1 modules, loop the door station
cables through the module locations.
The hub has ports for 6 zone keypads. Up to 6
ISH1 Hubs can be linked together for a maximum of
36 zones. With multiple hubs, each hub must be
assigned a unique ID number during installation.
When running CAT-5 and speaker cables, avoid AC
power wiring. If you have to run the cables parallel
to electrical wiring, space the cables at least two
feet (0.6 m) from the AC power lines.
The hub also has ports for 2 door stations. In a
system with multiple linked hubs, only the hub with
ID number 1 supports the door stations.
A separate doorbell chime tone can be selected on
hub 1 for each door. These chime selections take
effect for the entire system and play through all the
zone keypads.
The hub has 8-pole modular jacks for keypad and
door station connections. These connections must
be made according to the T568A standard as
shown in the diagram below.
The hub’s firmware contains lists of zone and door
labels for display on the ISK2 Advanced Keypads.
These labels are assigned by the installer using a
connected ISK2 keypad. (See the ComPoint system
manual for instructions on assigning labels.)
The hub also uses modular jacks for the link ports.
Use a short 8-pole, 4-twisted-pair straight-through
RJ-45 patch cable to link hubs together.
RJ-45 Using T568A
Wiring Standard
Designed for surface mounting or installation in a
structured wiring panel, the ISH1 Hub uses an exter-
nal model ISPS power supply to conserve chassis
space. It should be located near an electrical outlet.
The hub includes a port for updating its firmware
from a computer.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
INSTALLATION
ISK2
ISH1
ISPS
ISK3
ISK3
ISDR1
Six-zone ComPoint system with Advanced Keypads and an optional Door Strike Release Module
Download from Www.Somanuals.com. All Manuals Search And Download.
5
INSTALLATION
Programming
Hub ID Switch Settings (0 = Down, 1 = Up)
Hub ID
FW*
4
Switches
All system programming resides in the ISH1 Hub.
For a six-zone system with ISK1 Basic Keypads,
programming consists only of setting the doorbell
chimes. For a system with ISK2 Advanced Keypads,
programming includes assigning zone and door sta-
tion labels. For a system with more than six zones,
programming includes setting hub ID numbers.
1
0
0
0
0
1
1
2
0
0
1
1
0
0
3
0
1
0
1
0
1
Hub 1
Hub 2
Hub 3
Hub 4
Hub 5
Hub 6
1
1
1
1
1
1
When multiple hubs are used, the zone and door
label settings are initially stored in the hub to which
the keypad is connected. Upon exiting the program-
ming procedure, the settings are copied to the
other hubs.
*Switch 4 is for firmware updates
(0 = Update Mode, 1 = User Mode)
Table 1. Hub ID switch settings
Doorbell chimes
Hub 1 serves as the master hub for storing all zone
and door label settings. Whenever the system
power is cycled, the settings are copied from hub 1
to the other hubs.
A single 8-switch DIP assigns doorbell chimes for
both door stations. Switches 1 through 3 select the
chime for door 1 and switches 5 through 7 select
the chime for door 2. There are 7 chime options,
with a setting for no chime when a separate door-
bell system is used. To select the chimes, set the
switches as shown in table 2.
Hub ID numbers
In a system with multiple ISH1 Hubs, each hub must
have a unique ID number. This is manually assigned
on the 4-switch HUB ID DIP before the system is
powered up. To assign the ID number, set switches
1 through 3 as shown in table 1.
Switch 4 selects how the chime volume level is
managed. Setting the switch to 1 (up) sets the
chime volume level to a fixed level at 50% of the
maximum keypad output in all zones. This causes
the chime to play at the same level in all zones.
Setting the switch to 0 (down) allows the chime vol-
ume to be determined by the keypad volume level
setting in each zone independently.
Switch 4 enables a programming mode for updating
the system firmware. Leave this switch in the up
position for system operation.
Download from Www.Somanuals.com. All Manuals Search And Download.
6
INSTALLATION
Doorbell Chime Switch Settings (0 = Down, 1 = Up)
Technical Specifications
Door 1
CV*
4
Door 2
Switches
System
1
0
0
0
0
1
1
1
1
2
0
0
1
1
0
0
1
1
3
0
1
0
1
0
1
0
1
5
0
0
0
0
1
1
1
1
6
0
0
1
1
0
0
1
1
7
0
1
0
1
0
1
0
1
8
–
–
–
–
–
–
–
–
Maximum zones: 36 (up to 6 hubs)
Door stations: 2 maximum
None
0/1
0/1
0/1
0/1
0/1
0/1
0/1
0/1
Chime 1
Chime 2
Chime 3
Chime 4
Chime 5
Chime 6
Chime 7
Communications cable: CAT-5/CAT-5e
Maximum cable length: 250 feet (76 m)
ISH1 Hub
Keypad ports: (6) 8-pole modular RJ-45
Door station ports: (2) 8-pole modular RJ-45
Link ports: (2) 8-pole modular RJ-45
*Switch 4 is for chime volume
(0 = Keypad Adjustable, 1 = 50% Keypad Maximum)
Firmware update port: 4-pole port for Programming Cable,
Russound part #2500-521065
Table 2. Doorbell chime switch settings
Switches: 4-switch DIP for hub ID setting
8-switch DIP for 2 doorbell settings
Doorbell chimes (cont’d)
Potentiometer for doorbell volume
Switch 8 is currently not used.
Doorbell options: 7 chime patterns plus no chime
Power requirement: 15 VDC 3.5 A (Use model ISPS
power adapter)
The ISH1 Hub also has a trim potentiometer for set-
ting the overall volume of the doorbell chime
throughout the system. This can be used to adjust
the chime level relative to the communication level.
Mounting method: Surface or structured wiring panel
Dimensions: 6.438” W x 5.125” H x 1.813” D
(16.4 x 13.0 x 4.6 cm)
Weight: 25.6 oz (0.73 kg)
Note: In a system with multiple linked hubs, only the
settings on hub 1 affect the doorbell chime assign-
ments and volume level, since the door stations
connect only to hub 1. Because the settings take
effect immediately, the doorbell chimes can be set
at any time. There is no need to cycle the power
after setting them.
Download from Www.Somanuals.com. All Manuals Search And Download.
7
ComPoint™ ISH1 Hub
The music lover’s intercom solution
Instruction Manual
Warranty
The Russound ComPoint ISH1 Hub is fully guaranteed for two (2) years from the date of purchase against all defects in materials and
workmanship. For this warranty to apply, the unit must be installed and used according to its written instructions. During this period,
Russound will replace any defective parts and correct any defect in workmanship without charge for either parts or labor. Accidental
damage and shipping damage are not considered defects under the terms of this warranty. Russound assumes no responsibility for
defects resulting from abuse or servicing performed by an agency or person not specifically authorized in writing by Russound. If
service is necessary, it must be performed by Russound. Damage to or destruction of components due to excessive power voids
the warranty. In these cases, the repair will be made at the owner’s expense. To return for repairs, the unit must be shipped to
Russound at the owner’s expense, along with a note explaining the nature of the service required. Be sure to pack in a corrugated
container with at least 3 inches of resilient material to protect the unit from damage in transit.
Before returning a unit for repair, call Russound at 603.659.5170 for a Return Authorization number. Write the RA number on the
shipping label and ship to: Russound, 5 Forbes Road, Newmarket NH 03857.
Russound sells product only through authorized dealers and distributors to ensure that customers obtain proper support and serv-
ice. Any Russound product purchased from an unauthorized dealer or other source, including retailers, mail order sellers and online
sellers will not be honored or serviced under existing Russound warranty policy. Any sale of products by an unauthorized source or
other manner not authorized by Russound shall void the warranty on the applicable product.
Russound
5 Forbes Road, Newmarket NH 03857 USA
Tel 603.659.5170 • Fax 603.659.5388
28-1216 Revision 1 04/13/06
Copyright © 2006 Russound. All rights reserved. All trademarks are the property of their respective owners. Specifications are subject to change
without notice. Russound is not responsible for typographical errors or omissions.
Download from Www.Somanuals.com. All Manuals Search And Download.
|