H8/3937R H8/33937 Series TFP-100B
User System Interface Cable
(HS3937ECH61H)
for E6000 Emulator
User’s Manual
HS3937ECH61HE(B)
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
Thank you for purchasing this user system interface cable (HS3937ECH61H) for the Renesas’s
original microcomputer H8/3937R H8/3937 series.
The HS3937ECH61H is a user system interface cable that connects an H8/300L series E6000
emulator (HS388REPI60H; hereinafter referred to as the emulator) through the expansion board to
the IC socket for a TFP-100B package for the H8/3937R H8/3937 series MCU on the user system.
i
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Section 1 Configuration....................................................................................1
Section 2 Connection Procedures......................................................................3
2.1 Connecting User System Interface Cable to Emulator Station .........................................3
2.2 Connecting User System Interface Cable to User System ................................................5
2.2.1 Installing IC Socket .............................................................................................5
2.2.2 Soldering IC Socket.............................................................................................5
2.2.3 Inserting Cable Head ...........................................................................................6
2.2.4 Fastening Cable Head ..........................................................................................6
2.2.5 Fastening Cable Body..........................................................................................8
2.3 Recommended Dimensions for User System Mount Pad .................................................9
2.4 Dimensions for User System Interface Cable Head..........................................................10
2.5 Resulting Dimensions after Connecting User System Interface Cable.............................11
Section 4 Verifying Operation...........................................................................14
Section 5 Notice ................................................................................................16
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 1 Configuration
CAUTION
Use an IC149-100-054-B51 socket (manufactured by
YAMAICHI ELECTRONICS Co., Ltd.) for the TFP-100B
package IC socket on the user system.
Figure 1 shows the configuration of the HS3937ECH61H user system interface cable for the
TFP-100B package.
Figure 1 HS3937ECH61H User System Interface Cable
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1 lists the HS3937ECH61H components. Please make sure you have all of these components
when unpacking.
Table 1
HS3937ECH61H Components
No. Component
Quantity
Remarks
1
2
3
4
5
6
7
Cable body
1
1
1
1
4
4
1
Flat cable
Cable head
IC socket
For the TFP-100B package
Socket cover
For installing an TFP-100B packaged MCU
For fastening cable head
Screws (M2.6 x 12 mm)
Screws (M2.6 x 6 mm)
Documentation
For installing an TFP-100B packaged MCU
User’s manual for HS3937ECH61H (this manual)
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 2 Connection Procedures
2.1
Connecting User System Interface Cable to Emulator Station
WARNING
Observe the precautions listed below. Failure to do so
will result in a FIRE HAZARD and will damage the user
system and the emulator product or will result in
PERSONAL INJURY. The USER PROGRAM will be
LOST.
1. Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE CABLE
is connected to or removed from any part. Before
connecting, make sure that pin 1 on both sides are
correctly aligned.
2. The user system interface cable dedicated to the
emulator must be used.
To connect the cable body to the emulator station, follow the instructions below.
1. Make sure the user system and emulator station are turned off.
CAUTION
When connecting or removing the user system interface
cable, apply force only in the direction suitable for
connection or removal, while making sure not to bend or
twist the cable or connectors. Otherwise, the connectors
will be damaged. The user system interface cable must be
connected to an H8/300L Series E6000 emulator through the
H8/3937 Series expansion board. Do not connect the user
system interface cable directly to the E6000 emulator.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
2. [1] After making sure the direction of the expansion board connector labeled E6000
EMULATOR is correct, firmly insert the expansion board connector into the emulator
station connector ([1] in figure 2).
[2] Connect the expansion board labeled USER INTERFACE CABLE and the user system
interface cable body.
Emulator station
0
0
0
6
E
[1]
E
6
Expansion board
0
0 0
E M
U L A
T
O
R
E
L
B
CA
E
C
A
F
160kHz
TER
N
I
E E6 R0 0 0
US
Cable body connector
[2]
Subclock selection
User system interface cable
Figure 2 Connecting User System Interface Cable to Expansion Board
4
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2
Connecting User System Interface Cable to User System
WARNING
Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE CABLE
is connected to or removed from any part. Before
connecting, make sure that pin 1 on both sides are correctly
aligned. Failure to do so will result in a FIRE HAZARD and
will damage the user system and the expansion board or
will result in PERSONAL INJURY. The USER PROGRAM will
be LOST.
To connect the cable head to the user system, follow the instructions below.
2.2.1 Installing IC Socket
After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of
the IC socket for an TFP-100B package, and fasten it to the user system before soldering.
2.2.2
Soldering IC Socket
After fastening, solder the IC socket for an TFP-100B package to the user system. Be sure to
completely solder the leads so that the solder slops gently over the leads and forms solder fillets.
(Use slightly more solder than the MCU.)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2.3
Inserting Cable Head
CAUTION
Check the location of pin 1 before inserting.
Align pin 1 on the IC socket for an TFP-100B package on the user system with pin 1 on the user
system interface cable head, and insert the user system interface cable head into the IC socket on the
user system, as shown in figure 3.
2.2.4
Fastening Cable Head
CAUTION
1. Use a Philips-type screwdriver whose head matches the
screw head.
2. The tightening torque must be 0.054 N•m or less.
If the applied torque cannot be accurately measured,
stop tightening when the force required to turn the screw
becomes significantly greater than that needed when first
tightening. If a screw is tightened too much, the screw
head may break or an IC socket contact error may be
caused by a crack in the IC socket solder.
3. If the emulator does not operate correctly, cracks might
have occurred in the solder. Check conduction with
a tester and re-solder the IC socket if necessary.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Fasten the user system interface cable head to the IC socket for an TFP-100B package on the user
system with the four screws (M2.6 x 12 mm; with flat washers) provided. Each screw should be
tightened a little at a time, alternating between screws on opposing corners. Take special care, such
as manually securing the IC socket soldered area, to prevent the soldered IC socket from being
damaged by overtightening the screws or twisting the components.
Cable head
User system
Figure 3 Connecting User System Interface Cable to User System
7
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3
Recommended Dimensions for User System Mount Pad
Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with
an IC socket for an TFP-100B package (IC149-100-054-B51: manufactured by YAMAICHI
ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those
of the actual chip's mount pad.
Figure 5 Recommended Dimensions for Mount Pad
9
Download from Www.Somanuals.com. All Manuals Search And Download.
2.5
Resulting Dimensions after Connecting User System Interface Cable
The resulting dimensions, after connecting the user system interface cable head to the user system,
are shown in figure 7.
Figure 7 Resulting Dimensions after Connecting User System Interface Cable
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3 Installing the MCU to the User System
CAUTION
1. Check the location of pin 1 before inserting.
2. Use a Philips-type screwdriver whose head matches the
screw head.
3. The tightening torque must be 0.054 N•m or less.
If the applied torque cannot be accurately measured,
stop tightening when the force required to turn the screw
becomes significantly greater than that needed when first
tightening. If a screw is tightened too much, the screw
head may break or an IC socket contact error may be
caused by a crack in the IC socket solder.
4. If the MCU does not operate correctly, cracks might have
occurred in the solder. Check conduction with a tester
and re-solder the IC socket if necessary.
Check the location of pin 1 before inserting the MCU into the IC socket on the user system, as
shown in figure 8. After inserting the MCU, fasten the socket cover with the provided four screws
(M2.6 x 6 mm; with flat washers). Take special care, such as manually securing the IC socket
soldered area, to prevent the IC socket from being damaged by overtightening the screws or twisting
the components.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 8 Installing MCU to User System
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 4 Verifying Operation
1. When using the H8/300L series E6000 emulator (HS388REPI60H), turn on the emulator
according to the procedures described in the H8/300L Series E6000 Emulator User's Manual
(HS388REPI60HE).
2. Verify the user system interface cable connections by accessing ports and checking the bus
states of the pins. If an error is detected, recheck the soldered IC socket and the location of
pin 1.
3. System Clock (OSC2, 1)
When the system clock is selected in the HDI Configuration Window and jumper P4 is set in the
user system interface cable, the system clocks in table 2 can be selected (see figures 9
and 10).
Table 2
Setting System Clocks
Configuration Window
User System Interface Cable (P4)
System Clock (∅)
2 MHz
For the setting of P4, either pins 1-2 2 MHz
or 2-3 can be connected.
Target/2
1-2 connected
2-3 connected
5 MHz
Target clock/2
4. Subclock (DX2, 1)
When the switch is set on the expansion I/O board (Subclock selection) and jumper P5 is set on
the user system interface cable, subclocks in table 3 can be selected. Select target subclock in
the Configuration window (see figures 9 and 10).
Table 3
Setting Subclocks
Expansion I/O Board
(Subclock selection)
User System Interface Cable (P5)
Subclock (fW)
160 kHz
160 kHz
1-2 connected
76.8 kHz
76.8 kHz
The setting of the subclock
selection switch can be either
160 kHz or 76.8 kHz.
2-3 connected
Target subclock
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 9 shows the Expansion I/O board Subclock Selection, and figure 10 shows the location of
jumpers P4 and P5.
Figure 11 shows the system clock oscillator on the user system interface cable and the subclock
input specifications.
160kHz
E 6 0 0 0
76.8kHz
Subclock selection
Figure 9 Expansion I/O board Subclock Selection
Figure 10 P4 and P5 Jumpers
Figure 11 System Clock Oscillator and Subclock Input Specifications
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 5 Notice
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable
head before inserting the cable head into the user system IC socket.
2. The dimensions of the recommended mount pad for the user system IC socket are different from
those of the MCU.
3. To avoid breaking wires in the cable body, do not place heavy or sharp metal objects on the user
system interface cable.
4. While the emulator station is connected to the user system with the user system interface cable,
force must not be applied to the cable head. Position the emulator station, user system interface
cable, and user system as shown in figure 12.
Figure 12 User System Interface Cable Location Example
5. The P1 jumper is used for testing. Do not remove the inserted jumper pin.
Figure 13 P1 Jumper
16
Download from Www.Somanuals.com. All Manuals Search And Download.
|