Raritan Engineering Marine Sanitation System Crown Head II User Guide |
crown head II™
ELECTRIC MARINE TOILET
OPERATION, MAINTENANCE, and INSTALLATION INSTRUCTIONS
Manufactured after June 2002
THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND
FOLLOWED DURING BOTH INSTALLATION AND OPERATION.
WARNING: RaritanEngineeringCompany, Inc. recommendsthataqualifiedpersonorelectricianinstallthis
product. Equipment damage, injury to personnel or death could result from improper installa-
tion. Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to
equipment, or injury or death to personnel that may result from improper installation or
operation of this product.
WARNING: RISK OF SHOCK OR FIRE - Always use recommended fuse/circuit breaker and wire size.
Motors in this product are “Ignition Protected”. They are not however, explosion-proof as
defined in 46CFR 110.15-65(e), Subchapter J-Electrical Engineering.
WARNING: RISK OF FLOODING-Always shut off seacock(s) before leaving the boat unattended.
Whenever possible hose connections should be secured using two stainless steel hose clamps.
Integrity of clamps, hoses and fittings should be checked periodically.
Crown Head II Sea Water Model
Crown Head II Pressurized Freshwater Model
The Crown Head II is an automatic electric
macerating toilet available in Freshwater or
Sea Water flushing.
Four different Flush Control options are
available:
1. Push Button activation - Standard
2. Timed Flush with Push Button - RTC
3. Timed Flush with wall mounted touch
pad - TC*+,*specify voltage and +color
4. Momentary Flush with ability to con-
trol intake and discharge seperately -
SWF100
1-800-352-5630
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
Cleaning Instructions
IMPORTANT: Do not use cleaners that contain
ammonia, ethyl acetate, phosphoric acid or
concentrated chlorine bleach. These will cause
damage to the toilet.
Using C.P. (#1PCP22), a bio-enzymatic toilet bowl
cleaner (available from Raritan Engineering), will
keep the bowl clean and fresh smelling.
Recommend Visual Inspection
✔ For leaks at toilet and hose connections
✔ Hose clamps
✔ Condition of hoses
✔ Seacocks
✔ Condition of wires and connections
✔ In-Line Strainer
Cleaning In-Line Strainer
(Sea Water Models only)
1. Shut off intake seacock.
2. Unscrew strainer bowl.
Clean Gasket
and Gasket
Contact Surfaces
Thoroughly
Filter
3. Remove filter.
4. Clean bowl and filter with a clean dry cloth.
5. Clean gasket and gasket contact surfaces
thoroughly.
Bowl
6. Replace gasket, filter and bowl.
7. Open seacock.
Tighten
Unscrew
8. Check for leaks.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
WINTERIZING
IMPORTANT
•
Improper winter lay up is a major cause of
marine toilet failure.
•
•
Use only nontoxic antifreeze.
Flush toilet several times to clear waste from
system.
•
•
Dispose of all antifreeze in accordance with
local and federal regulations.
Winterize holding tanks, plumbing,
treatment systems (MSD’s), etc.
independently following manufacturer’s
instructions.
Sea Water Model
Parts Required
•
1 1/2" (38mm) I.D. piece of hose,
approximately 3 feet (1m) long
•
3/4" (19mm) I.D. piece of hose, approximately
3 feet (1m) long
•
•
Two buckets
Nontoxic antifreeze approximately 1 quart
(1 liter)
Steps
1. Close intake and discharge seacocks.
2. Turn off power to unit.
3. Disconnect and drain intake hose, discharge
hose and in-line strainer.
4. Connect short hoses to toilet’s intake and
discharge.
Nontoxic
antifreeze
5. Place one bucket under hose connected to
toilet’s discharge.
6. Pour antifreeze in other bucket.
7. Place hose connected to intake pump into
bucket with antifreeze.
8. Turn on power to unit and flush until antifreeze
is removed from toilet.
9. Disconnect power to toilet.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Pressurized Fresh Water Model
Parts Required
•
1 1/2" (38mm) I.D. hose, approximately 3 feet
(1m) long
•
•
Two buckets
Nontoxic antifreeze approximately 1 quart
(1 liter)
Steps
1. Close discharge seacock
2. Shut off intake water at source.
3. Turn off power to unit.
Nontoxic
antifreeze
4. Disconnect and drain discharge hose.
5. Disconnect intake hoses from vacuum breaker
and place in one of the buckets.
6. Connect hose to toilet’s discharge and place in
the other bucket.
7. Pour antifreeze in bowl.
8. Turn on power to unit and flush until antifreeze
is removed from toilet and water is drained
from intake lines.
Allow water
to drain
into bucket
9. Disconnect power to toilet.
10. Reconnect intake hoses to vacuum breaker.
RECOMMISSIONING
1. Using buckets, hoses, and clean fresh water,
flush antifreeze out of system (see Winterizing).
Dispose of antifreeze in accordance with local
and federal regulations.
2. Reconnect intake and discharge hoses and open
both seacocks.
3. Check all connections for leaks with several
test flushes.
SYSTEM START-UP
1. Open seacock(s).
NOTE: Pressurized freshwater models; open water
source valve.
2. Turn on power to toilet.
3. Flush toilet per Operation Instructions.
Check for leaks.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Parts Included
•
Fuse/circuit breaker
Tools Required
All Toilets
•
•
5/16" nut driver
Toilet Bowl (Household or Marine)
Seat and Cover
Wrench or screw driver (depending on mounting
fastener)
Discharge pump assembly
Heavy Duty Push Button Switch (#164000)
Mounting pads
•
Bit for drilling mounting surface (depending on
fastener used)
•
•
•
•
Wire cutters
Lower Motor Cover
Wire terminal crimpers
Hose cutters
Sea Water Model
Remote Intake Pump
Tape measure
3/4" Hose Barb straight fitting
3/4" Hose Barb - 90° elbow fitting
Plug Fitting
In-Line Strainer with fittings
3/4" Stainless Steel Hose Clamps (2)
Pressurized Freshwater Models
Atmospheric Vacuum Breaker with fittings
Solenoid Valve with fittings
Solenoid Valve Mounting Bracket
Flush Control Options
Toilet Control (#TC*+) wall switch
Raritime Control (#RTC*) times the push button
Flush Control (#SWF100+) independant control
Additional Parts Required
•
Four 1/4" (6mm) stainless steel mounting
bolts or lag screws and washers (Sea Water
Models)
•
•
Two1/4" (6mm) stainless steel mounting bolts
or lag screws and washers (Freshwater Models)
Four 5/16" (8mm) stainless steel mounting
bolts or lag screws and washers
•
•
•
1 1/2" (38mm) I.D. discharge hose
3/4" (19mm) I.D. reinforced intake hose
3/4" (19mm) and 1 1/2" (38mm) hose clamps
(two for each connection below waterline)
•
•
Wire
Terminals
* Specify Voltage
+ Specify Color
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
Bowl Depth:
Bowl Width:
19 1/4" (48.9cm) Household
14 3/8" (36.6cm) Household
16 3/4" (42.6cm) Marine
13" (33cm) Marine
Height:
17 3/8"
(44.1cm)
Household
17" (43.2cm
Marine
Base Depth:
10 7/8"
Base Width:
10 1/2"
(27.6cm)
(26.8cm)
Plumbing
Maximum suction of Intake pump
(Maximum height above waterline)
4 Ft. (1.2m) from Intake Pump
6 Ft. (1.8m) from base of toilet
Maximum height of discharge
vented loop
Pressurized water source must provide a minimum flow rate of 3 gallons
(11.3 liters) per minute at a minimum pressure of 5 psi (34.5 kPa).
NOTES: for Wire Sizes
1. Distances are from source (battery) to unit and back to source (battery).
2. Recommended conductor wire minimum AWG (mm2) for 3% voltage drop.
3. Recommended conductor sizes are based on 105°C rated insulation.
Refer to ABYC Standards for other insulation ratings.
Recommended Wire and Breaker Sizes for Crown Head II with Diaphragm Intake Pump
Distance (feet) and Wire (AWG)
10' 15' 20' 25' 30' 40' 50'
Main Circuit
Breaker/Fuse Amps Assembly Amps
Discharge Pump Diaphragm Intake
Units
Voltage
Pump Amps
40
20
15
18
9
10
5
10
8
6
6
4
4
2
8
12V DC
24V DC
32V DC
16 14 12 12 10 10
7
4
16 16 16 16 16 16 14
Recommended Wire and Breaker Sizes for Crown Head II with Pressurized Freshwater
Distance (feet) and Wire (AWG)
10' 15' 20' 25' 30' 40' 50'
Discharge Pump
Assembly Amps
Water Solenoid
Valve Amps
Main Circuit
Breaker/Fuse Amps
Units
Voltage
18
9
1
10 10
8
8
6
6
4
25
15
10
12V DC
24V DC
32V DC
.5
.5
16 16 14 12 12 10 10
16 16 16 14 14 12 12
7
Branch Circuit Wire to Water Solenoid Valve: use 16 AWG Wire
Wire Sizes Conversion Table
Feet to Meter Conversion Table
AWG 16
14
12
10
8
6
4
2
Feet 10
15
20
25
30
40
50
mm2 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0
Meter
3.1 4.6 6.1 7.2 9.2 12.2 15.2
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting Toilet
Mounting surface must be flat and solid.
IMPORTANT: Do not mount where it may be
subject to shower spray or other sources of
external water.
1. Install seat on toilet.
2. Place toilet where it will be located.
Make sure there is room to route hoses.
Make sure seat will open properly.
3. Mark location of toilet base mounting holes on
mounting surface.
4. Drill holes for toilet mounting bolts/screws.
NOTE: Hole size will depend on type of bolt/screws
used (5/16" [8mm] size bolts/screws are
recommended).
5. Mark locations for hoses where required.
6. Cut holes for hoses.
7. Place rubber mounting strips under base plate.
8. Secure toilet to surface.
Mounting Water Solenoid Valve
(Pressurized Freshwater Models Only)
1. Locate valve on a solid flat surface in an area
that is dry and well ventilated.
2. Mark and drill holes for water solenoid mounting
bracket.
NOTE: Hole size will depend on type of bolts/screws
used (1/4" [6mm] size bolt/screws are
recommended).
3. Mount bracket.
4. Install fittings provided (PLA14) on valve’s inlet
and outlet ports.
5. Attach valve to bracket. Valve must be mounted
according to flow markings on valve body.
From
Pressurized
Freshwater
Source
IN
PLA14
OUT
To Crown Head II
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting Atmospheric Vacuum Breaker
(Pressurized Freshwater Model only)
1. Install fittings as shown.
6"
(15.3cm)
2. Locate mounting area that is a minimum of
6" (15.3cm) above toilet.
3. Secure where top is in horizontal position.
Mounting In-Line Strainer
(Seawater Models Only)
Make sure strainer bowl is tight.
1. Locate strainer where it will be accessible.
2. Mark and drill mounting holes.
Flow Marking
NOTE: Hole size will depend on type of bolts/
screws used (1/4" [6mm] size bolts/screws are
recommended).
3. Install fittings provided (#PLA14) on strainer’s
inlet and outlet ports.
4. Mount strainer. Strainer must be mounted
according to flow markings on strainer body.
Mounting Remote Intake Pump
(Sea Models Only)
1. Locate on a flat solid surface in an area that is
dry and well ventilated.
NOTE: Location should not be greater than 48"
(122cm) above the waterline.
2. Mark and drill mounting holes.
NOTE: Hole size will depend on type of bolts/
screws used (1/4" [6mm] size bolts/screws are
recommended).
3. Mount pump. Do not over tighten bolts.
Installing Lower Cover
1. Slide cover over lower unit.
2. Secure in place with plastic beaded tie.
NOTE: Do not install until installation is
completed.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Intake Pump Model
Mounted Above Waterline
PLUMBING
Remote
Intake
Pump
Crown head II
WARNING: Hazard of Flooding
Discharge
Vented
Loop
Toilets mounted at or below the waterline must
have a vented loop installed in the discharge
line. The top of the vented loop must be a
minimum of 4" (10cm) above the waterline at
the boats greatest angle of heel (see vented loop
manufacturer’s instructions).
Holding Tank
Lectra/San
Waterline
Waterline
In-Line
Strainer
Y Valve
Discharge
Seacock
Intake
Seacock
Sea Water Models must also have a vented loop
installed between the intake pump and the
toilet bowl.
Double clamp all below waterline connections.
Remote Intake Pump Model
Mounted Below Waterline
•
Hazard of potable water contamination.
Vacuum breaker must be installed with
installations using potable water.
Intake
Vented
Loop
Discharge
Vented
Loop
IMPORTANT:
Waterline
Waterline
Crown head II
•
Fittings and 90° bends should be kept to a
minimum.
Lectra/San
•
In-Line Strainer must be installed before
the Remote Intake pump. Failure to do so
may void warranty.
Intake
Seacock
Discharge
Seacock
In-Line
Strainer
Remote Intake
Pump
•
Discharging untreated sewage is restricted
in all U. S. waters within the three-mile
limit. If boating outside of U.S. Boundaries
check with local authorities for their rules
and regulations.
Pressurized Freshwater Model
Installed Above Waterline
•
Thru-hull fittings and seacocks must be
installed where they are easily accessible.
•
•
Use only quality reinforced hoses.
Secure all hoses properly.
Waterline
e
Discharge Lines
1. Connect quality 1 1/2" (38mm) sanitation
hose to discharge fitting on toilet.
2. Run hose to appropriate device (i.e.: treatment
system, holding tank, etc.).
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Intake Lines
From Pressurized
Freshwater Source
(Shut Off Valve)
Pressurized Freshwater Models
Install a shut off valve in intake line before water
solenoid valve.
1. Connect hose from pressurized freshwater
source to a shut off valve.
2. Connect hose from shut off valve to inlet port
of water solenoid valve.
IN
OUT
NOTE: To avoid malfunction of water solenoid
due to debris in water, installation of Freshwater
Strainer (FWSC*) is recommended.
3. Connect hose from outlet port of water solenoid
valve to inlet port of vacuum breaker.
4. Connect hose from outlet port of vacuum
breaker to toilet bowl.
To Inlet Port of
Vacuum Breaker
Outlet Port
Inlet Port
Outlet Port
Arrow
Sea Water Models
Intake pump fittings are interchangeable to allow
more flexibility during installation. There are two
inlet ports on either side of the intake pump. The
outlet port (to toilet bowl) is at the top of the intake
pump (Arrow).
1. Slide fitting clips back.
2. Select inlet port to be used.
3. Install the appropriate fittings into inlet and
outlet ports used.
4. Install the plug fitting into unused inlet port.
IMPORTANT: Be sure not to install plug fitting
into outlet port! Damage will occur!
5. Reinstall fitting clips.
NOTE: The 90° fitting can be rotated 360°.
From
Seacock
6. Connect hose from seacock to inlet port of
In-Line Strainer.
7. Connect hose from outlet port of In-Line
Strainer to inlet port of intake pump.
IMPORTANT: Double clamp all below
waterline hose connections!
8. Connect hose from outlet port of intake
pump to bowl elbow located on back of toilet
bowl.
To Intake
Pump
11
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING
WARNING: Hazard of Shock and Fire
•
Always use proper wire, wire connectors
and fuse/circuit breaker. See Specification
Chart on page 7.
•
•
Secure wire properly.
Do not connect other appliances to toilet
circuit.
Remote Intake Pump Wiring
•
Make sure power is off before proceeding.
NOTE: Figures shown with installation of Push
Button Switch (#164000).
Refer to manuals included with Toilet Control
(TC*+), Raritime Solid State Timer with Solenoid
(#RTC), or Flush Control (#SWF100+) for wiring
Instructions.
1. Determine proper size wire.
Measure distance from:
•
•
Power source to Push Button Switch.
Push Button Switch to toilet (and Remote
Intake Pump if used).
•
•
•
Toilet to ground source.
Determine total distance of wire needed.
Select proper size wire from Specification
Chart on page 7.
2. Select proper size fuse/circuit breaker from
Specifications Chart on page 7.
Pressurized Freshwater Wiring
3. Install fuse/circuit breaker in positive line at
source.
4. Connect positive wire from fuse/circuit breaker
to Push Button Switch.
Push Button
Switch
#164000)
5. Connect wire from Push Button Switch to
orange wire on remote intake pump motor and
positive terminal on discharge pump motor.
POS (+)
3 Amp
Fuse
NOTE: Pressurized Freshwater Models; connect
wire from Push Button Switch to positive terminal
on discharge pump motor and from Push Button
Switch to one of the wires on water solenoid valve.
The water solenoid valve is not polarity sensitive.
Fuse or
Circuit
Breaker
Solenoid
Valve
6. Connect wire from battery negative or power
source ground buss to black wire on remote
intake pump motor and negative terminal on
discharge pump motor.
NEG (-)
NEG POS
NOTE: Pressurized Freshwater Models; connect
remaining wire from water solenoid valve to
battery negative or power source ground buss.
* Specify Voltage
+ Specify Color
12
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
Possible Cause
Conclusion
Problem
A. Poor Discharge, A1. Clogged or restricted discharge line.
A1. Be sure discharge seacock is open. Clean lines. Remove clog.
Especially Solids: A2. Too many bends or ells in discharge line. A2. Replumb to eliminate bends and ells.
A3. Clogged holding tank or vented loops.
A4. Mineral buildup in hoses and fittings.
A5. Low voltage.
A3. Clean vents and any vent valves.
A4. Manually clean affected parts and/or replace hoses.
A5. Check voltage at toilet while running. If less than nominal
voltageoftoilet(12,24,32,120V),checkconditionofbatteries.
Check terminals and wire connections for corrosion (heat at
terminalsandjunctionsindicatesabadorcorrodedconnection).
Check gauge of wire to be sure it is not undersize, see
Specification Table.
A6. Damage to pump wall.
A7. Full holding tank.
A6. Replace CH120.
A7. Find a pump out station.
B. Poor Water Flow, B1. Head not level.
B1. Raise rear of toilet; check with level.
Especially at Front B2. Restriction in line to Intake Pump or B2. Be sure seacock is open. Clear line - remove clog. Clean
ofBowl(ornowater
flow):
clogged strainer.
B3. Intake Pump sucking air.
strainer.
B3. Check all connections from intake thru-hull to Intake Pump to
be sure no air leaks are present.
B4. See A5, above.
B4. Low voltage to Intake Pump.
B5. Intakepumpsvalvesanddiaphragmworn. B5. Replace valves and diaphragm.
ForPressurizedFreshwa- B1A.Inadequate water supply to water sole- B1A.Check available water flow; requires minimum of three GPM
tertoiletsonly. Poor
intake water flow.
noid valve.
at bowl elbow. 1) Increase line pressure. 2) Install larger
piping. 3) Install higher capacity pressure pump.
B2A.Clogged water solenoid valve.
B2A.Disassemble and clean waterb solenoid valve. Install Fresh
water strainer (#FWSC) in supply line to water solenoid valve.
B3A.Faulty or malfunctioning water solenoid B3A.Rebuild or replace water solenoid valve.
valve or coil.
C. Foul Odors From C1. “Marine life” lodged in rim of bowl.
Toilet Area:
C1. Remove and flush bowl with pressure hose to remove all
material. Install strainer in intake line to avoid recurrence.
C2. Replace plastic hose with quality sanitation hose (#SH) with
smooth interior .
C2. Improper discharge hose.
C3. Sewage remaining in discharge line.
C3. Flush toilet long enough to insure waste has passed out of hose.
Replace plastic hose with quality sanitation hose (#SH).
C4. Clean vents and any vent valves.
D. Close seacocks one at a time to determine which one is causing
problem. If intake, install vented loop between pressure side
ofpumpandbowl. Ifdischarge,installventedloopindischarge
line. If problem continues, contact Raritan Technical Support.
C4. Clogged holding tank vent.
D. BowlFillsUpWhile D. Pressure buildup at seacock(s).
Boat is Underway:
E. Bowl Fills Up E1. Freshwatermodels: Watersolenoidvalve E1. Remove supply hose between toilet and water solenoid valve
WhetherorNotBoat
is Underway:
not shutting completely off.
at water solenoid valve. If continuous dripping or seeping is
noted,watersolenoidvalveshouldbedisassembledandcleaned.
If problem persists, rebuild or replace water solenoid valve.
Water solenoid valve requires a minimum of 5 psi at all times
at intake of the valve to stay closed.
E2. Raw water models: Below waterline E2. Remove vent from vented loop. Clean out foreign matter.
toilet, vent of vented loop is clogged.
Install an In-Line strainer (#163000) in supply line to Intake
Pump.
F. Water
Leaking F1. Leaking bowl gasket.
F1. Tighten (4) bowl mounting nuts.
From Macerator:
F2. Leaking front cover.
F2. Removefrontcover (#CH18)andinspect“O”ringfordamage.
Replace “O” ring if necessary using Super Lube or waterproof
grease to reassemble.
F3. Leaks at hoses or fittings.
F4. Leaking macerator shaft seal.
G. Loud Noises Ema- G1. Object jammed in macerator.
F3. Check all connections; be sure clamps are tight.
F4. Return to factory for repairs or exchange.
G1. Remove front cover and remove object.
nating From Toilet: G2. Motor bearings damaged by macerator G2. Return motor to factory for servicing or replacement.
seal leak.
Tip for Removing Intake Pump
Set screw must be loosened
with 1/8" hex key before
removing the intake pump
from motor
Plug
13
Download from Www.Somanuals.com. All Manuals Search And Download.
CROWN HEAD II - Parts List
Part #
Description
Part #
C250
C253
Description
Beaded Wire Tie
Joker Valve
1118
Lockwasher (4)
1222AW 90 Degree discharge (opt.)
1222B
1226B
1234
Straight discharge
1/4" - 20 S/S Hex Nut (4)
Bowl Gasket
C290
Discharge Adapter
CH119MWDischarge Impeller Assy. includes CH119M,
F149VT [2])
1236AW Bowl Spud Assembly
CH120
CH121
Discharge Pump Wall
Macerator
1236E
Bowl Elbow
1237W
Marine-size Bowl Assembly (White) CH15DD End Bell
(Not shown)
CH18W
Front Cover w/"O" Ring
Front Cover Screw (6
Mounting Screw (4)10-32x5/8" S/S
Woodruff Key
1238A
1244AW
Marine-sizeSeatandCover(White)(Notshown) CH26
Household-style Bowl Assembly, (Bone) CH27
includes 1236AW
Household-style Bowl Assembly, (White) CH38
includes 1236AW CH51
Household-style Seat and Cover (White) CH52
(Not shown) CH55
Household-style Seat and Cover (Bone) CH57
CH34
1244W
1245
Bowl Stud (4)
Base Mounting Screw (4)
Rubber Mounting Strip (2), (Not shown)
Base Plate
1245A
Rubber Slinger
(Not shown)
Discharge Screw (2)
Front Cover O-Ring
CH58
CH59
CH92
Fillister Head Screw (4) 10-32x3/4" S/S
Seal
Square Rubber Gasket
Discharge Impeller and Macerator Assembly
includesCH120,CH121,F149VT(2),CH119MW
Set Screw
Piston Fastener (4)
Mounting Bolt Washer (4)
Set Screw (2)
1341
161107
162000W Intake Pump Assembly includes 162100W, CR1
162200W, 162300W
162100W Upper Housing Assembly
162200W Middle Housing Assembly
162300W Lower Housing Assembly
F005
F020
F144
F149VT
F161
F162VT
LWPLUG 3/8" Plastic Plug
M23A
M30
162135
162225
162305
162310
162315
162320
Cone Seal
O-Ring
Lower Housing includes 162315
Diaphragm includes 162315
Piston (4)
Cap Fastener (4)
Mounting Bolt
#10 Lockwasher (4)
Piston Seat (4) includes 162315
1/4" - 20 Brass Nut (4)
#14 Brass Washer (4)
Nylon Shoulder Washer (4)
162325A BearingPlateAssemblyincludesF005, 162315 M31
162405
162410
162415
162420
162425
163000
164000
1660*A
166000
3/4" Hose Barb - 90° Fitting
3/4" Hose Barb - Straight Fitting
Plug Fitting
Fitting Clip (3)
Fitting O-Ring (3)
In-line Strainer
Heavy Duty Push Button Switch (Not shown)
Remote Motor
Diaphragm Intake Pump Assembly 12V
includes 162100W, 162200W, 162300W,
1660*A
Diaphragm Intake Pump Assembly 24V
includes 162100W, 162200W, 162300W,
1660*A
Diaphragm Intake Pump Assembly 32V
includes 162100W, 162200W, 162300W,
1660*A
Motor Shaft Seal w/316 Spring (Not shown)
Crown Head II Motor, 12, 24, 32 VDC
Lower Cover, Bone, Household-style
Lower Cover, White, Household-style
RNI
WATER SOLENOID VALVE
CWPS*A 1/2" GC Solenoid Valve
CWPSMB Mounting Bracket for CWPS (Not shown)
PLA7
Male Adapter 1/2 MNPTx3/4 Barb (2)
ATMOSPHERIC VACUUM BREAKER
PLAVB0-5 Atmospheric Vacuum Breaker
PLA13
PLA14
Elbow, 1/2” NPT x 3/4”
Male Adapter 1/2 MNPTx3/4 Barb
ADDITIONAL ACCESSORIES AVAILABLE
TC*+
FWSC
RTC*
Toilet Control (Not shown)
Fresh Water Strainer (Not shown)
Raritime Solid State Timer with solenoid
(Not shown)
166100
166200
SH
Sanitation Hose (Not shown)
SWF100+ Flush Control (Not shown)
TWK
VL1½W
Toilet Water Kit (Not shown)
Vented Loop 1½" (Not shown)
31-102
C2M*
C246
C247
* Specify Voltage
+ Specify Color
14
Download from Www.Somanuals.com. All Manuals Search And Download.
CROWN HEAD II - EXPLODED PARTS VIEW
Water Solenoid Valve
In-Line Strainer
163000
Atmospheric Vacuum Breaker
PLAVB0-5
PLA14
162320
162420
5
162310
F162VT
15
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITED WARRANTY
Raritan Engineering Company warrants to the original purchaser that this product is free of defects in
materials or workmanship for a period of one year from the product’s date of purchase. Should this
product prove defective by reason of improper workmanship and/or materials within the warranty
period, Raritan shall, at its sole option, repair or replace the product.
1. TO OBTAIN WARRANTY SERVICE, Consumer must deliver the product prepaid, together with a
detailed description of the problem, to Raritan at 530 Orange St., Millville, N.J. 08332, or 3101 SW 2nd
Ave. Ft. Lauderdale, FL 33315. When requesting warranty service, purchaser must present a sales slip
or other document which establishes proof of purchase. THE RETURN OF THE OWNER
REGISTRATION CARD IS NOT A CONDITION PRECEDENT OF WARRANTY COVERAGE.
However,pleasecompleteandreturntheownerRegistrationCardsothatRaritancancontactyoushould
a question of safety arise which could affect you.
2. THIS WARRANTY DOES NOT COVER defects caused by modifications, alterations, repairs or
service of this product by anyone other than Raritan; defects in materials or workmanship supplied by
others in the process of installation of this product; defects caused by installation of this product other
than in accordance with the manufacturer’s recommended installation instructions or standard industry
procedures; physical abuse to, or misuse of, this product. This warranty also does not cover damages
to equipment caused by fire, flood, external water, excessive corrosion or Act of God.
3. ANY EXPRESS WARRANTY NOT PROVIDED HEREIN, AND ANY REMEDY FOR BREACH
OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BY IMPLICATION OR
OPERATION OF LAW, IS HEREBY EXCLUDED AND DISCLAIMED. ALL IMPLIED
WARRANTIES SUCH AS THOSE OF MERCHANTABILITY AND OF FITNESS FOR A
PARTICULAR PURPOSE, IF APPLICABLE, AS WELL AS ANY IMPLIED WARRANTIES
WHICH MIGHT ARISE BY IMPLICATION OF LAW, ARE EXPRESSLY LIMITED TO A TERM
OF ONE YEAR. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG A LIMITED
WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
4. UNDER NO CIRCUMSTANCES SHALL RARITAN BE LIABLE TO PURCHASER OR ANY
OTHERPERSONSFORANYSPECIALORCONSEQUENTIALDAMAGES,WHETHERARISING
OUT OF BREACH OF WARRANTY, BREACH OF CONTRACT, OR OTHERWISE. SOME
STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT
APPLY TO YOU.
5. No other person or entity is authorized to make any express warranty, promise or affirmation of fact or
to assume any other liability on behalf of Raritan in connection with its products except as specifically
set forth in this warranty.
6. This warranty gives you specific legal rights, and you may also have other rights which vary from state
to state.
530 Orange Street, Millville, NJ 08332 USA
Telephone: 856-825-4900 FAX: 856-825-4409
Southern Office and Plant:
3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA
Telephone: 954-525-0378 FAX: 954-764-4370
L339 0407kgs
Specifications Subject to Change Without Notice
Printed in U.S.A.
16