Raritan Engineering Marine Sanitation System Crown Head II User Guide

crown head II™  
ELECTRIC MARINE TOILET  
OPERATION, MAINTENANCE, and INSTALLATION INSTRUCTIONS  
Manufactured after June 2002  
THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND  
FOLLOWED DURING BOTH INSTALLATION AND OPERATION.  
WARNING: RaritanEngineeringCompany, Inc. recommendsthataqualifiedpersonorelectricianinstallthis  
product. Equipment damage, injury to personnel or death could result from improper installa-  
tion. Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to  
equipment, or injury or death to personnel that may result from improper installation or  
operation of this product.  
WARNING: RISK OF SHOCK OR FIRE - Always use recommended fuse/circuit breaker and wire size.  
Motors in this product are “Ignition Protected”. They are not however, explosion-proof as  
defined in 46CFR 110.15-65(e), Subchapter J-Electrical Engineering.  
WARNING: RISK OF FLOODING-Always shut off seacock(s) before leaving the boat unattended.  
Whenever possible hose connections should be secured using two stainless steel hose clamps.  
Integrity of clamps, hoses and fittings should be checked periodically.  
Crown Head II Sea Water Model  
Crown Head II Pressurized Freshwater Model  
The Crown Head II is an automatic electric  
macerating toilet available in Freshwater or  
Sea Water flushing.  
Four different Flush Control options are  
available:  
1. Push Button activation - Standard  
2. Timed Flush with Push Button - RTC  
3. Timed Flush with wall mounted touch  
pad - TC*+,*specify voltage and +color  
4. Momentary Flush with ability to con-  
trol intake and discharge seperately -  
SWF100  
1-800-352-5630  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
Cleaning Instructions  
IMPORTANT: Do not use cleaners that contain  
ammonia, ethyl acetate, phosphoric acid or  
concentrated chlorine bleach. These will cause  
damage to the toilet.  
Using C.P. (#1PCP22), a bio-enzymatic toilet bowl  
cleaner (available from Raritan Engineering), will  
keep the bowl clean and fresh smelling.  
Recommend Visual Inspection  
For leaks at toilet and hose connections  
Hose clamps  
Condition of hoses  
Seacocks  
Condition of wires and connections  
In-Line Strainer  
Cleaning In-Line Strainer  
(Sea Water Models only)  
1. Shut off intake seacock.  
2. Unscrew strainer bowl.  
Clean Gasket  
and Gasket  
Contact Surfaces  
Thoroughly  
Filter  
3. Remove filter.  
4. Clean bowl and filter with a clean dry cloth.  
5. Clean gasket and gasket contact surfaces  
thoroughly.  
Bowl  
6. Replace gasket, filter and bowl.  
7. Open seacock.  
Tighten  
Unscrew  
8. Check for leaks.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
WINTERIZING  
IMPORTANT  
Improper winter lay up is a major cause of  
marine toilet failure.  
Use only nontoxic antifreeze.  
Flush toilet several times to clear waste from  
system.  
Dispose of all antifreeze in accordance with  
local and federal regulations.  
Winterize holding tanks, plumbing,  
treatment systems (MSD’s), etc.  
independently following manufacturer’s  
instructions.  
Sea Water Model  
Parts Required  
1 1/2" (38mm) I.D. piece of hose,  
approximately 3 feet (1m) long  
3/4" (19mm) I.D. piece of hose, approximately  
3 feet (1m) long  
Two buckets  
Nontoxic antifreeze approximately 1 quart  
(1 liter)  
Steps  
1. Close intake and discharge seacocks.  
2. Turn off power to unit.  
3. Disconnect and drain intake hose, discharge  
hose and in-line strainer.  
4. Connect short hoses to toilet’s intake and  
discharge.  
Nontoxic  
antifreeze  
5. Place one bucket under hose connected to  
toilet’s discharge.  
6. Pour antifreeze in other bucket.  
7. Place hose connected to intake pump into  
bucket with antifreeze.  
8. Turn on power to unit and flush until antifreeze  
is removed from toilet.  
9. Disconnect power to toilet.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pressurized Fresh Water Model  
Parts Required  
1 1/2" (38mm) I.D. hose, approximately 3 feet  
(1m) long  
Two buckets  
Nontoxic antifreeze approximately 1 quart  
(1 liter)  
Steps  
1. Close discharge seacock  
2. Shut off intake water at source.  
3. Turn off power to unit.  
Nontoxic  
antifreeze  
4. Disconnect and drain discharge hose.  
5. Disconnect intake hoses from vacuum breaker  
and place in one of the buckets.  
6. Connect hose to toilet’s discharge and place in  
the other bucket.  
7. Pour antifreeze in bowl.  
8. Turn on power to unit and flush until antifreeze  
is removed from toilet and water is drained  
from intake lines.  
Allow water  
to drain  
into bucket  
9. Disconnect power to toilet.  
10. Reconnect intake hoses to vacuum breaker.  
RECOMMISSIONING  
1. Using buckets, hoses, and clean fresh water,  
flush antifreeze out of system (see Winterizing).  
Dispose of antifreeze in accordance with local  
and federal regulations.  
2. Reconnect intake and discharge hoses and open  
both seacocks.  
3. Check all connections for leaks with several  
test flushes.  
SYSTEM START-UP  
1. Open seacock(s).  
NOTE: Pressurized freshwater models; open water  
source valve.  
2. Turn on power to toilet.  
3. Flush toilet per Operation Instructions.  
Check for leaks.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Parts Included  
Fuse/circuit breaker  
Tools Required  
All Toilets  
5/16" nut driver  
Toilet Bowl (Household or Marine)  
Seat and Cover  
Wrench or screw driver (depending on mounting  
fastener)  
Discharge pump assembly  
Heavy Duty Push Button Switch (#164000)  
Mounting pads  
Bit for drilling mounting surface (depending on  
fastener used)  
Wire cutters  
Lower Motor Cover  
Wire terminal crimpers  
Hose cutters  
Sea Water Model  
Remote Intake Pump  
Tape measure  
3/4" Hose Barb straight fitting  
3/4" Hose Barb - 90° elbow fitting  
Plug Fitting  
In-Line Strainer with fittings  
3/4" Stainless Steel Hose Clamps (2)  
Pressurized Freshwater Models  
Atmospheric Vacuum Breaker with fittings  
Solenoid Valve with fittings  
Solenoid Valve Mounting Bracket  
Flush Control Options  
Toilet Control (#TC*+) wall switch  
Raritime Control (#RTC*) times the push button  
Flush Control (#SWF100+) independant control  
Additional Parts Required  
Four 1/4" (6mm) stainless steel mounting  
bolts or lag screws and washers (Sea Water  
Models)  
Two1/4" (6mm) stainless steel mounting bolts  
or lag screws and washers (Freshwater Models)  
Four 5/16" (8mm) stainless steel mounting  
bolts or lag screws and washers  
1 1/2" (38mm) I.D. discharge hose  
3/4" (19mm) I.D. reinforced intake hose  
3/4" (19mm) and 1 1/2" (38mm) hose clamps  
(two for each connection below waterline)  
Wire  
Terminals  
* Specify Voltage  
+ Specify Color  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
Bowl Depth:  
Bowl Width:  
19 1/4" (48.9cm) Household  
14 3/8" (36.6cm) Household  
16 3/4" (42.6cm) Marine  
13" (33cm) Marine  
Height:  
17 3/8"  
(44.1cm)  
Household  
17" (43.2cm
Marine  
Base Depth:  
10 7/8"  
Base Width:  
10 1/2"  
(27.6cm)  
(26.8cm)  
Plumbing  
Maximum suction of Intake pump  
(Maximum height above waterline)  
4 Ft. (1.2m) from Intake Pump  
6 Ft. (1.8m) from base of toilet  
Maximum height of discharge  
vented loop  
Pressurized water source must provide a minimum flow rate of 3 gallons  
(11.3 liters) per minute at a minimum pressure of 5 psi (34.5 kPa).  
NOTES: for Wire Sizes  
1. Distances are from source (battery) to unit and back to source (battery).  
2. Recommended conductor wire minimum AWG (mm2) for 3% voltage drop.  
3. Recommended conductor sizes are based on 105°C rated insulation.  
Refer to ABYC Standards for other insulation ratings.  
Recommended Wire and Breaker Sizes for Crown Head II with Diaphragm Intake Pump  
Distance (feet) and Wire (AWG)  
10' 15' 20' 25' 30' 40' 50'  
Main Circuit  
Breaker/Fuse Amps Assembly Amps  
Discharge Pump Diaphragm Intake  
Units  
Voltage  
Pump Amps  
40  
20  
15  
18  
9
10  
5
10  
8
6
6
4
4
2
8
12V DC  
24V DC  
32V DC  
16 14 12 12 10 10  
7
4
16 16 16 16 16 16 14  
Recommended Wire and Breaker Sizes for Crown Head II with Pressurized Freshwater  
Distance (feet) and Wire (AWG)  
10' 15' 20' 25' 30' 40' 50'  
Discharge Pump  
Assembly Amps  
Water Solenoid  
Valve Amps  
Main Circuit  
Breaker/Fuse Amps  
Units  
Voltage  
18  
9
1
10 10  
8
8
6
6
4
25  
15  
10  
12V DC  
24V DC  
32V DC  
.5  
.5  
16 16 14 12 12 10 10  
16 16 16 14 14 12 12  
7
Branch Circuit Wire to Water Solenoid Valve: use 16 AWG Wire  
Wire Sizes Conversion Table  
Feet to Meter Conversion Table  
AWG 16  
14  
12  
10  
8
6
4
2
Feet 10  
15  
20  
25  
30  
40  
50  
mm2 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0  
Meter  
3.1 4.6 6.1 7.2 9.2 12.2 15.2  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting Toilet  
Mounting surface must be flat and solid.  
IMPORTANT: Do not mount where it may be  
subject to shower spray or other sources of  
external water.  
1. Install seat on toilet.  
2. Place toilet where it will be located.  
Make sure there is room to route hoses.  
Make sure seat will open properly.  
3. Mark location of toilet base mounting holes on  
mounting surface.  
4. Drill holes for toilet mounting bolts/screws.  
NOTE: Hole size will depend on type of bolt/screws  
used (5/16" [8mm] size bolts/screws are  
recommended).  
5. Mark locations for hoses where required.  
6. Cut holes for hoses.  
7. Place rubber mounting strips under base plate.  
8. Secure toilet to surface.  
Mounting Water Solenoid Valve  
(Pressurized Freshwater Models Only)  
1. Locate valve on a solid flat surface in an area  
that is dry and well ventilated.  
2. Mark and drill holes for water solenoid mounting  
bracket.  
NOTE: Hole size will depend on type of bolts/screws  
used (1/4" [6mm] size bolt/screws are  
recommended).  
3. Mount bracket.  
4. Install fittings provided (PLA14) on valve’s inlet  
and outlet ports.  
5. Attach valve to bracket. Valve must be mounted  
according to flow markings on valve body.  
From  
Pressurized  
Freshwater  
Source  
IN  
PLA14  
OUT  
To Crown Head II  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting Atmospheric Vacuum Breaker  
(Pressurized Freshwater Model only)  
1. Install fittings as shown.  
6"  
(15.3cm)  
2. Locate mounting area that is a minimum of  
6" (15.3cm) above toilet.  
3. Secure where top is in horizontal position.  
Mounting In-Line Strainer  
(Seawater Models Only)  
Make sure strainer bowl is tight.  
1. Locate strainer where it will be accessible.  
2. Mark and drill mounting holes.  
Flow Marking  
NOTE: Hole size will depend on type of bolts/  
screws used (1/4" [6mm] size bolts/screws are  
recommended).  
3. Install fittings provided (#PLA14) on strainer’s  
inlet and outlet ports.  
4. Mount strainer. Strainer must be mounted  
according to flow markings on strainer body.  
Mounting Remote Intake Pump  
(Sea Models Only)  
1. Locate on a flat solid surface in an area that is  
dry and well ventilated.  
NOTE: Location should not be greater than 48"  
(122cm) above the waterline.  
2. Mark and drill mounting holes.  
NOTE: Hole size will depend on type of bolts/  
screws used (1/4" [6mm] size bolts/screws are  
recommended).  
3. Mount pump. Do not over tighten bolts.  
Installing Lower Cover  
1. Slide cover over lower unit.  
2. Secure in place with plastic beaded tie.  
NOTE: Do not install until installation is  
completed.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Intake Pump Model  
Mounted Above Waterline  
PLUMBING  
Remote  
Intake  
Pump  
Crown head II  
WARNING: Hazard of Flooding  
Discharge  
Vented  
Loop  
Toilets mounted at or below the waterline must  
have a vented loop installed in the discharge  
line. The top of the vented loop must be a  
minimum of 4" (10cm) above the waterline at  
the boats greatest angle of heel (see vented loop  
manufacturer’s instructions).  
Holding Tank  
Lectra/San  
Waterline  
Waterline  
In-Line  
Strainer  
Y Valve  
Discharge  
Seacock  
Intake  
Seacock  
Sea Water Models must also have a vented loop  
installed between the intake pump and the  
toilet bowl.  
Double clamp all below waterline connections.  
Remote Intake Pump Model  
Mounted Below Waterline  
Hazard of potable water contamination.  
Vacuum breaker must be installed with  
installations using potable water.  
Intake  
Vented  
Loop  
Discharge  
Vented  
Loop  
IMPORTANT:  
Waterline  
Waterline  
Crown head II  
Fittings and 90° bends should be kept to a  
minimum.  
Lectra/San  
In-Line Strainer must be installed before  
the Remote Intake pump. Failure to do so  
may void warranty.  
Intake  
Seacock  
Discharge  
Seacock  
In-Line  
Strainer  
Remote Intake  
Pump  
Discharging untreated sewage is restricted  
in all U. S. waters within the three-mile  
limit. If boating outside of U.S. Boundaries  
check with local authorities for their rules  
and regulations.  
Pressurized Freshwater Model  
Installed Above Waterline  
Thru-hull fittings and seacocks must be  
installed where they are easily accessible.  
Use only quality reinforced hoses.  
Secure all hoses properly.  
Waterline  
e  
Discharge Lines  
1. Connect quality 1 1/2" (38mm) sanitation  
hose to discharge fitting on toilet.  
2. Run hose to appropriate device (i.e.: treatment  
system, holding tank, etc.).  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intake Lines  
From Pressurized  
Freshwater Source  
(Shut Off Valve)  
Pressurized Freshwater Models  
Install a shut off valve in intake line before water  
solenoid valve.  
1. Connect hose from pressurized freshwater  
source to a shut off valve.  
2. Connect hose from shut off valve to inlet port  
of water solenoid valve.  
IN  
OUT  
NOTE: To avoid malfunction of water solenoid  
due to debris in water, installation of Freshwater  
Strainer (FWSC*) is recommended.  
3. Connect hose from outlet port of water solenoid  
valve to inlet port of vacuum breaker.  
4. Connect hose from outlet port of vacuum  
breaker to toilet bowl.  
To Inlet Port of  
Vacuum Breaker  
Outlet Port  
Inlet Port  
Outlet Port  
Arrow  
Sea Water Models  
Intake pump fittings are interchangeable to allow  
more flexibility during installation. There are two  
inlet ports on either side of the intake pump. The  
outlet port (to toilet bowl) is at the top of the intake  
pump (Arrow).  
1. Slide fitting clips back.  
2. Select inlet port to be used.  
3. Install the appropriate fittings into inlet and  
outlet ports used.  
4. Install the plug fitting into unused inlet port.  
IMPORTANT: Be sure not to install plug fitting  
into outlet port! Damage will occur!  
5. Reinstall fitting clips.  
NOTE: The 90° fitting can be rotated 360°.  
From  
Seacock  
6. Connect hose from seacock to inlet port of  
In-Line Strainer.  
7. Connect hose from outlet port of In-Line  
Strainer to inlet port of intake pump.  
IMPORTANT: Double clamp all below  
waterline hose connections!  
8. Connect hose from outlet port of intake  
pump to bowl elbow located on back of toilet  
bowl.  
To Intake  
Pump  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WIRING  
WARNING: Hazard of Shock and Fire  
Always use proper wire, wire connectors  
and fuse/circuit breaker. See Specification  
Chart on page 7.  
Secure wire properly.  
Do not connect other appliances to toilet  
circuit.  
Remote Intake Pump Wiring  
Make sure power is off before proceeding.  
NOTE: Figures shown with installation of Push  
Button Switch (#164000).  
Refer to manuals included with Toilet Control  
(TC*+), Raritime Solid State Timer with Solenoid  
(#RTC), or Flush Control (#SWF100+) for wiring  
Instructions.  
1. Determine proper size wire.  
Measure distance from:  
Power source to Push Button Switch.  
Push Button Switch to toilet (and Remote  
Intake Pump if used).  
Toilet to ground source.  
Determine total distance of wire needed.  
Select proper size wire from Specification  
Chart on page 7.  
2. Select proper size fuse/circuit breaker from  
Specifications Chart on page 7.  
Pressurized Freshwater Wiring  
3. Install fuse/circuit breaker in positive line at  
source.  
4. Connect positive wire from fuse/circuit breaker  
to Push Button Switch.  
Push Button  
Switch  
#164000)  
5. Connect wire from Push Button Switch to  
orange wire on remote intake pump motor and  
positive terminal on discharge pump motor.  
POS (+)  
3 Amp  
Fuse  
NOTE: Pressurized Freshwater Models; connect  
wire from Push Button Switch to positive terminal  
on discharge pump motor and from Push Button  
Switch to one of the wires on water solenoid valve.  
The water solenoid valve is not polarity sensitive.  
Fuse or  
Circuit  
Breaker  
Solenoid  
Valve  
6. Connect wire from battery negative or power  
source ground buss to black wire on remote  
intake pump motor and negative terminal on  
discharge pump motor.  
NEG (-)  
NEG POS  
NOTE: Pressurized Freshwater Models; connect  
remaining wire from water solenoid valve to  
battery negative or power source ground buss.  
* Specify Voltage  
+ Specify Color  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
Possible Cause  
Conclusion  
Problem  
A. Poor Discharge, A1. Clogged or restricted discharge line.  
A1. Be sure discharge seacock is open. Clean lines. Remove clog.  
Especially Solids: A2. Too many bends or ells in discharge line. A2. Replumb to eliminate bends and ells.  
A3. Clogged holding tank or vented loops.  
A4. Mineral buildup in hoses and fittings.  
A5. Low voltage.  
A3. Clean vents and any vent valves.  
A4. Manually clean affected parts and/or replace hoses.  
A5. Check voltage at toilet while running. If less than nominal  
voltageoftoilet(12,24,32,120V),checkconditionofbatteries.  
Check terminals and wire connections for corrosion (heat at  
terminalsandjunctionsindicatesabadorcorrodedconnection).  
Check gauge of wire to be sure it is not undersize, see  
Specification Table.  
A6. Damage to pump wall.  
A7. Full holding tank.  
A6. Replace CH120.  
A7. Find a pump out station.  
B. Poor Water Flow, B1. Head not level.  
B1. Raise rear of toilet; check with level.  
Especially at Front B2. Restriction in line to Intake Pump or B2. Be sure seacock is open. Clear line - remove clog. Clean  
ofBowl(ornowater  
flow):  
clogged strainer.  
B3. Intake Pump sucking air.  
strainer.  
B3. Check all connections from intake thru-hull to Intake Pump to  
be sure no air leaks are present.  
B4. See A5, above.  
B4. Low voltage to Intake Pump.  
B5. Intakepumpsvalvesanddiaphragmworn. B5. Replace valves and diaphragm.  
ForPressurizedFreshwa- B1A.Inadequate water supply to water sole- B1A.Check available water flow; requires minimum of three GPM  
tertoiletsonly. Poor  
intake water flow.  
noid valve.  
at bowl elbow. 1) Increase line pressure. 2) Install larger  
piping. 3) Install higher capacity pressure pump.  
B2A.Clogged water solenoid valve.  
B2A.Disassemble and clean waterb solenoid valve. Install Fresh  
water strainer (#FWSC) in supply line to water solenoid valve.  
B3A.Faulty or malfunctioning water solenoid B3A.Rebuild or replace water solenoid valve.  
valve or coil.  
C. Foul Odors From C1. “Marine life” lodged in rim of bowl.  
Toilet Area:  
C1. Remove and flush bowl with pressure hose to remove all  
material. Install strainer in intake line to avoid recurrence.  
C2. Replace plastic hose with quality sanitation hose (#SH) with  
smooth interior .  
C2. Improper discharge hose.  
C3. Sewage remaining in discharge line.  
C3. Flush toilet long enough to insure waste has passed out of hose.  
Replace plastic hose with quality sanitation hose (#SH).  
C4. Clean vents and any vent valves.  
D. Close seacocks one at a time to determine which one is causing  
problem. If intake, install vented loop between pressure side  
ofpumpandbowl. Ifdischarge,installventedloopindischarge  
line. If problem continues, contact Raritan Technical Support.  
C4. Clogged holding tank vent.  
D. BowlFillsUpWhile D. Pressure buildup at seacock(s).  
Boat is Underway:  
E. Bowl Fills Up E1. Freshwatermodels: Watersolenoidvalve E1. Remove supply hose between toilet and water solenoid valve  
WhetherorNotBoat  
is Underway:  
not shutting completely off.  
at water solenoid valve. If continuous dripping or seeping is  
noted,watersolenoidvalveshouldbedisassembledandcleaned.  
If problem persists, rebuild or replace water solenoid valve.  
Water solenoid valve requires a minimum of 5 psi at all times  
at intake of the valve to stay closed.  
E2. Raw water models: Below waterline E2. Remove vent from vented loop. Clean out foreign matter.  
toilet, vent of vented loop is clogged.  
Install an In-Line strainer (#163000) in supply line to Intake  
Pump.  
F. Water  
Leaking F1. Leaking bowl gasket.  
F1. Tighten (4) bowl mounting nuts.  
From Macerator:  
F2. Leaking front cover.  
F2. Removefrontcover (#CH18)andinspectOringfordamage.  
Replace “O” ring if necessary using Super Lube or waterproof  
grease to reassemble.  
F3. Leaks at hoses or fittings.  
F4. Leaking macerator shaft seal.  
G. Loud Noises Ema- G1. Object jammed in macerator.  
F3. Check all connections; be sure clamps are tight.  
F4. Return to factory for repairs or exchange.  
G1. Remove front cover and remove object.  
nating From Toilet: G2. Motor bearings damaged by macerator G2. Return motor to factory for servicing or replacement.  
seal leak.  
Tip for Removing Intake Pump  
Set screw must be loosened  
with 1/8" hex key before  
removing the intake pump  
from motor  
Plug  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CROWN HEAD II - Parts List  
Part #  
Description  
Part #  
C250  
C253  
Description  
Beaded Wire Tie  
Joker Valve  
1118  
Lockwasher (4)  
1222AW 90 Degree discharge (opt.)  
1222B  
1226B  
1234  
Straight discharge  
1/4" - 20 S/S Hex Nut (4)  
Bowl Gasket  
C290  
Discharge Adapter  
CH119MWDischarge Impeller Assy. includes CH119M,  
F149VT [2])  
1236AW Bowl Spud Assembly  
CH120  
CH121  
Discharge Pump Wall  
Macerator  
1236E  
Bowl Elbow  
1237W  
Marine-size Bowl Assembly (White) CH15DD End Bell  
(Not shown)  
CH18W  
Front Cover w/"O" Ring  
Front Cover Screw (6  
Mounting Screw (4)10-32x5/8" S/S  
Woodruff Key  
1238A  
1244AW  
Marine-sizeSeatandCover(White)(Notshown) CH26  
Household-style Bowl Assembly, (Bone) CH27  
includes 1236AW  
Household-style Bowl Assembly, (White) CH38  
includes 1236AW CH51  
Household-style Seat and Cover (White) CH52  
(Not shown) CH55  
Household-style Seat and Cover (Bone) CH57  
CH34  
1244W  
1245  
Bowl Stud (4)  
Base Mounting Screw (4)  
Rubber Mounting Strip (2), (Not shown)  
Base Plate  
1245A  
Rubber Slinger  
(Not shown)  
Discharge Screw (2)  
Front Cover O-Ring  
CH58  
CH59  
CH92  
Fillister Head Screw (4) 10-32x3/4" S/S  
Seal  
Square Rubber Gasket  
Discharge Impeller and Macerator Assembly  
includesCH120,CH121,F149VT(2),CH119MW  
Set Screw  
Piston Fastener (4)  
Mounting Bolt Washer (4)  
Set Screw (2)  
1341  
161107  
162000W Intake Pump Assembly includes 162100W, CR1  
162200W, 162300W  
162100W Upper Housing Assembly  
162200W Middle Housing Assembly  
162300W Lower Housing Assembly  
F005  
F020  
F144  
F149VT  
F161  
F162VT  
LWPLUG 3/8" Plastic Plug  
M23A  
M30  
162135  
162225  
162305  
162310  
162315  
162320  
Cone Seal  
O-Ring  
Lower Housing includes 162315  
Diaphragm includes 162315  
Piston (4)  
Cap Fastener (4)  
Mounting Bolt  
#10 Lockwasher (4)  
Piston Seat (4) includes 162315  
1/4" - 20 Brass Nut (4)  
#14 Brass Washer (4)  
Nylon Shoulder Washer (4)  
162325A BearingPlateAssemblyincludesF005, 162315 M31  
162405  
162410  
162415  
162420  
162425  
163000  
164000  
1660*A  
166000  
3/4" Hose Barb - 90° Fitting  
3/4" Hose Barb - Straight Fitting  
Plug Fitting  
Fitting Clip (3)  
Fitting O-Ring (3)  
In-line Strainer  
Heavy Duty Push Button Switch (Not shown)  
Remote Motor  
Diaphragm Intake Pump Assembly 12V  
includes 162100W, 162200W, 162300W,  
1660*A  
Diaphragm Intake Pump Assembly 24V  
includes 162100W, 162200W, 162300W,  
1660*A  
Diaphragm Intake Pump Assembly 32V  
includes 162100W, 162200W, 162300W,  
1660*A  
Motor Shaft Seal w/316 Spring (Not shown)  
Crown Head II Motor, 12, 24, 32 VDC  
Lower Cover, Bone, Household-style  
Lower Cover, White, Household-style  
RNI  
WATER SOLENOID VALVE  
CWPS*A 1/2" GC Solenoid Valve  
CWPSMB Mounting Bracket for CWPS (Not shown)  
PLA7  
Male Adapter 1/2 MNPTx3/4 Barb (2)  
ATMOSPHERIC VACUUM BREAKER  
PLAVB0-5 Atmospheric Vacuum Breaker  
PLA13  
PLA14  
Elbow, 1/2” NPT x 3/4”  
Male Adapter 1/2 MNPTx3/4 Barb  
ADDITIONAL ACCESSORIES AVAILABLE  
TC*+  
FWSC  
RTC*  
Toilet Control (Not shown)  
Fresh Water Strainer (Not shown)  
Raritime Solid State Timer with solenoid  
(Not shown)  
166100  
166200  
SH  
Sanitation Hose (Not shown)  
SWF100+ Flush Control (Not shown)  
TWK  
VL1½W  
Toilet Water Kit (Not shown)  
Vented Loop 1½" (Not shown)  
31-102  
C2M*  
C246  
C247  
* Specify Voltage  
+ Specify Color  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CROWN HEAD II - EXPLODED PARTS VIEW  
Water Solenoid Valve  
In-Line Strainer  
163000  
Atmospheric Vacuum Breaker  
PLAVB0-5  
PLA14  
162320  
162420  
5  
162310  
F162VT  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIMITED WARRANTY  
Raritan Engineering Company warrants to the original purchaser that this product is free of defects in  
materials or workmanship for a period of one year from the product’s date of purchase. Should this  
product prove defective by reason of improper workmanship and/or materials within the warranty  
period, Raritan shall, at its sole option, repair or replace the product.  
1. TO OBTAIN WARRANTY SERVICE, Consumer must deliver the product prepaid, together with a  
detailed description of the problem, to Raritan at 530 Orange St., Millville, N.J. 08332, or 3101 SW 2nd  
Ave. Ft. Lauderdale, FL 33315. When requesting warranty service, purchaser must present a sales slip  
or other document which establishes proof of purchase. THE RETURN OF THE OWNER  
REGISTRATION CARD IS NOT A CONDITION PRECEDENT OF WARRANTY COVERAGE.  
However,pleasecompleteandreturntheownerRegistrationCardsothatRaritancancontactyoushould  
a question of safety arise which could affect you.  
2. THIS WARRANTY DOES NOT COVER defects caused by modifications, alterations, repairs or  
service of this product by anyone other than Raritan; defects in materials or workmanship supplied by  
others in the process of installation of this product; defects caused by installation of this product other  
than in accordance with the manufacturer’s recommended installation instructions or standard industry  
procedures; physical abuse to, or misuse of, this product. This warranty also does not cover damages  
to equipment caused by fire, flood, external water, excessive corrosion or Act of God.  
3. ANY EXPRESS WARRANTY NOT PROVIDED HEREIN, AND ANY REMEDY FOR BREACH  
OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BY IMPLICATION OR  
OPERATION OF LAW, IS HEREBY EXCLUDED AND DISCLAIMED. ALL IMPLIED  
WARRANTIES SUCH AS THOSE OF MERCHANTABILITY AND OF FITNESS FOR A  
PARTICULAR PURPOSE, IF APPLICABLE, AS WELL AS ANY IMPLIED WARRANTIES  
WHICH MIGHT ARISE BY IMPLICATION OF LAW, ARE EXPRESSLY LIMITED TO A TERM  
OF ONE YEAR. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG A LIMITED  
WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.  
4. UNDER NO CIRCUMSTANCES SHALL RARITAN BE LIABLE TO PURCHASER OR ANY  
OTHERPERSONSFORANYSPECIALORCONSEQUENTIALDAMAGES,WHETHERARISING  
OUT OF BREACH OF WARRANTY, BREACH OF CONTRACT, OR OTHERWISE. SOME  
STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR  
CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT  
APPLY TO YOU.  
5. No other person or entity is authorized to make any express warranty, promise or affirmation of fact or  
to assume any other liability on behalf of Raritan in connection with its products except as specifically  
set forth in this warranty.  
6. This warranty gives you specific legal rights, and you may also have other rights which vary from state  
to state.  
530 Orange Street, Millville, NJ 08332 USA  
Telephone: 856-825-4900 FAX: 856-825-4409  
Southern Office and Plant:  
3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA  
Telephone: 954-525-0378 FAX: 954-764-4370  
L339 0407kgs  
Specifications Subject to Change Without Notice  
Printed in U.S.A.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Quatech Network Card DSCLP 100 User Guide
Radio Shack Caller ID Box 43 968 User Guide
Radio Shack Cordless Telephone 43 3581 User Guide
Raymarine GPS Receiver 530 User Guide
RCA Flat Panel Television J32L637 H 0 User Guide
RocketFish Corded Headset RF JJX15 User Guide
Samsung Cell Phone 9630 User Guide
Sanyo Flat Panel Television DP26649 User Guide
Seagate Computer Drive ST120HM000 User Guide
Sennheiser Headphones HD 218i User Guide