Rangemaster Ventilation Hood RMG1H60SG User Guide

RMG1H60SG  
RMG1H90SG  
Instructions Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RECOMMENDATIONS AND SUGGESTIONS  
The Instructions for Use apply to several versions of this appliance. Accord-  
ingly, you may find descriptions of individual features that do not apply to  
your specific appliance.  
INSTALLATION  
The manufacturer will not be held liable for any damages resulting from in-  
correct or improper installation.  
The minimum safety distance between the cooker top and the extractor  
hood is 450 mm.  
Check that the mains voltage corresponds to that indicated on the rating  
plate fixed to the inside of the hood.  
For Class I appliances, check that the domestic power supply guarantees  
adequate earthing.  
Connect the extractor to the exhaust flue through a pipe of minimum diame-  
ter 120 mm. The route of the flue must be as short as possible.  
Do not connect the extractor hood to exhaust ducts carrying combustion  
fumes (boilers, fireplaces, etc.).  
• If the extractor is used in conjunction with non-electrical appliances (e.g. gas  
burning appliances), a sufficient degree of aeration must be guaranteed in  
the room in order to prevent the backflow of exhaust gas. The kitchen must  
have an opening communicating directly with the open air in order to  
guarantee the entry of clean air.  
450 mm min.  
USE  
The extractor hood has been designed exclusively for domestic use to elimi-  
nate kitchen smells.  
Never use the hood for purposes other than for which it has ben designed.  
Never leave high naked flames under the hood when it is in operation.  
Adjust the flame intensity to direct it onto the bottom of the pan only, making  
sure that it does not engulf the sides.  
Deep fat fryers must be continuously monitored during use: overheated oil  
can burst into flames.  
Do not flambè under the range hood; risk of fire  
This appliance is not intended for use by persons (including children) with  
reduced physical, sensory or mental capabilities, or lack of experience and  
knowledge, unless they have been given supervision or instruction concern-  
ing use of the appliance by a person responsible for their safety.  
Children should be supervised to ensure that they do not play with the appli-  
ance.  
MAINTENANCE  
Switch off or unplug the appliance from the mains supply before carrying out  
any maintenance work.  
Clean and/or replace the Filters after the specified time period.  
Clean the hood using a damp cloth and a neutral liquid detergent.  
The symbol  
on the product or on its packaging indicates that this product may not be treated  
as household waste. Instead it shall be handed over to the applicable collection point for the  
recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly,  
you will help prevent potential negative consequences for the environment and human health,  
which could otherwise be caused by inappropriate waste handling of this product. For more  
detailed information about recycling of this product, please contact your local city office, your  
household waste disposal service or the shop where you purchased the product.  
EN  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHARACTERISTICS  
Dimensions  
EN  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Components  
Ref. Q.ty Product Components  
15  
1
1
Hood Body, complete with: Controls, Light,  
Blower, Filters  
14.1  
2
1
1
1
1
1
2
1
Telescopic Chimney comprising:  
Upper Section  
Lower Section  
Reducer Flange ø 150-120 mm  
Adapting ring ø 120-125 mm  
Air Outlet Connection Extension  
Air Outlet Connection  
7.3  
2.1  
2.2  
9
10  
14.1  
15  
12a 7.2.1  
11  
10  
9
Ref. Q.ty Installation Components  
7.2.1  
7.3  
11  
12a  
12c  
2
1
6
6
6
Upper Chimney Section Fixing Brackets  
Air Outlet Connection Support  
Wall Plugs  
Screws 4,2 x 44,4  
Screws 2,9 x 9,5  
2.1  
2.2  
12c  
2
Q.ty Documentation  
Instruction Manual  
1
11  
12a  
1
EN  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Wall drilling and bracket fixing  
7.2.1  
11  
116 116  
12a  
Wall marking:  
• Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the  
centre of the area in which the hood will be installed.  
• Draw a horizontal line at 1040 mm above the hob.  
• Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit align-  
ing the centre (notch) with the vertical reference line.  
• Mark the wall at the centres of the holes in the bracket.  
• Place bracket 7.2.1 on the wall as shown at X mm below the first bracket (X = height of the  
upper chimney section supplied), aligning the centre (notch) with the vertical line.  
• Mark the wall at the centres of the holes in the bracket.  
• Mark a reference point as indicated at 116 mm from the vertical reference.  
• Repeat this operation on the other side.  
• Drill ø 8 mm holes at all the centre points marked.  
• Insert the wall plugs 11 in the holes.  
• Fix the lower bracket 7.2.1 using the 12a screws (4,2 x 44,4) supplied.  
• Fix the upper bracket 7.2.1 and the air outlet connection support 7.3 together using the 2  
screws 12a (4,2 x 44,4) supplied.  
• Insert the two screws 12a (4,2 x 44,4) supplied in the hood body fixing holes, leaving a gap  
of 5-6 mm between the wall and the head of the screw.  
EN  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting the hood body  
• Before attaching the hood body, tighten the two screws Vr lo-  
cated on the hood body mounting points.  
Vr  
• Hook the hood body onto the screws 12a.  
• Fully tighten support screws 12a.  
• Adjust screws Vr to level the hood body.  
12a  
Connections  
DUCTED VERSION AIR EXHAUST SYSTEM  
ø 150  
ø 125  
When installing the ducted version, connect the hood to the  
chimney using either a flexible or rigid pipe ø 150 or 125 mm,  
the choice of which is left to the installer.  
10  
9
• To install a ø 125 mm air exhaust connection, insert the re-  
ducer flange 9 on the hood body air outlet and the adapting  
ring ø120-125 10 on the reducer flange.  
• Fix the pipe in position using sufficient pipe clamps (not sup-  
plied).  
• Remove any activated charcoal filters.  
14.1  
7.3  
15  
RECIRCULATION VERSION AIR OUTLET  
• Insert the connection extension pieces laterally 14.1 in connec-  
tion 15.  
• Insert the Connector 15 into the Support bracket 7.3 and fix it  
with a screw.  
• Make sure that the outlet of the extension pieces 14.1 is hori-  
zontally and vertically aligned with the chimney outlets.  
• Connect the air outlet connection 15 to the hood body outlet  
using either a flexible or rigid pipe ø 150 mm, the choice of  
which is left to the installer.  
ø 150  
• Ensure that the activated charcoal filters have been inserted.  
7
EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CONNECTION  
• Connect the hood to the mains through a two-pole switch hav-  
ing a contact gap of at least 3 mm.  
• Remove the grease filters (see paragraph Maintenance) being  
sure that the connector of the feeding cable is correctly inserted  
in the socket placed on the side of the fan.  
7.2.1  
Flue assembly  
12c  
12c  
Upper exhaust flue  
• Slightly widen the two sides of the upper flue and hook them  
behind the brackets 7.2.1, making sure that they are well  
seated.  
• Secure the sides to the brackets using the 4 screws 12c (2,9 x  
9,5) supplied.  
2.1  
2.2  
2
• Make sure that the outlet of the extensions pieces is aligned  
with the chimney outlets.  
12c  
Lower exhaust flue  
• Slightly widen the two sides of the flue and hook them be-  
tween the upper flue and the wall, making sure that they are  
well seated.  
• Fix the lower part laterally to the hood body using the 2 screws  
12c (2,9 x 9,5) supplied.  
EN  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
USE  
F
L
A
E
G
B
C
I
D
H
Control board  
Key Function  
Display  
A
Switches the extractor motor on and off at the latest Indicates the selected speed.  
selected speed  
B
C
D
Decreases the suction speed.  
Increases the suction speed.  
By pressing this key it is possible to start the inten- I flashes and the LEDS are all lit.  
sive speed from any previously selected speed ex- By pressing the key the function is  
cept the Delay-function and 24H-function. This stopped.  
speed has been timed at 10 minutes. After that time  
The number of lit LEDS decreases.  
The number of lit LEDS increases.  
the system activates automatically the latest selected  
speed. This function is suitable for cooking condi-  
tions when vapours and smells are at the utmost e-  
mission.  
E
F
By pressing this key it is possible to set up the motor 24 appears and the LEDS extinguish one  
to a suction speed at 100 m3/h .  
by one.  
By pressing the key the function is  
stopped  
By pressing this key it is possible to set the delayed A flashing clock-symbol appears.  
shutdown of the motor and the lighting to 30 min- By pressing the key the function is  
utes. This function is suitable for a complete elimi- stopped  
nation of residual cooking odours. Functioning only  
when the motor is on(not during the 24H-function or  
intensive function). By pressing the key the function  
is stopped  
G
By pressing this key for about 2 seconds it is possi- After 100 working hours a drop-symbol  
ble to reset the filter saturation alarm  
appears. Metal grease filters have to be  
washed.  
After 200 working hours  
C
appears.  
Charcoal filters have to replaced.  
H
I
By pressing this key the intensity of the lighting  
system can be decreased.  
Switches on/off the lighting system at the maximum  
intensity.  
L
By pressing this key the intensity of the lighting  
system can be increased.  
Keyboard lock: it is possible to jam the keyboard when, for example, cleaning the glass. The  
motor and lights are switched off.  
By pressing the F-key (Delay) for about 5 seconds the keyboard block can be activated or de-  
activated. This function is confirmed by a Beep and by moving motor LEDS on display.  
EN  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
REMOTE CONTROL (OPTIONAL)  
The appliance can be controlled using a remote control powered  
by a 1.5 V carbon-zinc alkaline batteries of the standard LR03-  
AAA type.  
• Do not place the remote control near to heat sources.  
• Used batteries must be disposed of in the proper manner.  
Cleaning the Comfort Panels  
• Pull the Comfort Panel to open it.  
• Disconnect the panel from the hood canopy by sliding the fix-  
ing pin lever.  
• The comfort panel must never be washed in a dishwasher.  
• Clean the outside using a damp cloth and neutral liquid deter-  
gent.  
• Clean the inside as well using a damp cloth and neutral deter-  
gent; do not use wet cloths or sponges, or jets of water; do not  
use abrasive substances.  
• When the above operation has been completed, hook the panel  
back to the hood canopy and close it by turning the knob in the  
opposite direction.  
EN  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Metal grease filters  
Metal filters can be washed also in a dish machine.  
They need to be washed every time a drop-symbol ap-  
pears in the display or at least every two months. In ca-  
se of very frequent use these have to be washed even  
more often.  
Alarm reset  
• Press the G-key for at least 2 seconds.  
Cleaning  
• Open the comfort panel.  
• Remove the filters one by one by pushing them  
backwards and pulling them down contemporane-  
ously.  
• Wash the filters. Pay attention not to bend them.  
Make sure that filters are completely dry before put-  
ting them into their seat. (a possible modification of  
the filter surface doesn’t influence its efficiency).  
• Place the filters again into their seats and make sure  
that the handle of the filter remains outside.  
• Close the comfort panel.  
ATTENTION: Remove the filters one by one pushing  
them towards the back side of the hood and simultane-  
ously pulling downwards and towards the centre of the  
hood (only in case of 60 cm hood version).  
EN  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Charcoal filter (recycling version)  
This filter cannot be washed or regenerated. It must be replaced when the C appears on the  
display or at least once every 4 months. The filter saturation alarm has to be activated already  
before.  
Activation of the alarm signal  
• In the recycling version hoods the filter saturation alarm must be activated during the instal-  
lation or later.  
• Switch off the hood and the lights.  
• Press the E-key for about 5 seconds until the last two segments of the motor LEDS are lit on  
the display.  
• By releasing the E-key the clock icon starts to flash.  
• Within 3 seconds press the D-key to activate/deactivate charcoal filter saturation alarm.  
C-symbol lit - charcoal filter saturation alarm ACTIVATED.  
C-symbol unlit - charcoal filter saturation alarm DEACTIVATED.  
SUBSTITUTION OF THE CHARCOAL FILTER  
Alarm reset  
• Switch off the motor and the lighting system.  
• Press the G-key for at least 2 seconds.  
Substitution of the filter  
• Open the confort panel.  
• Remove the metal grease filters.  
• Remove the charcoal filter as indicated in the picture.  
• Place the filter again into its seat.  
• Place again the metal grease filters into their place.  
Lighting  
LIGHT REPLACEMENT  
20 W halogen light.  
• Remove the 2 screws fixing the Lighting support, and pull it  
out of from the Hood.  
• Extract the lamp from the Support.  
• Replace with another of the same type, making sure that the  
two pins are properly inserted in the lamp holder socket holes.  
• Replace the Support, fixing it in place with the two screws re-  
moved as above.  
EN  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AGA RANGEMASTER LTD.  
436004190_ver1  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Radio Shack Cordless Telephone 43 3537 User Guide
RCA Telephone 26925 User Guide
Regency Stove U38 LP User Guide
Roberts Gorden Gas Heater CTU 22 TO 115 User Guide
Roland DJ Equipment DJ 1000 User Guide
Samsung Cell Phone 010505D5 User Guide
Samsung Flat Panel Television W17M24C User Guide
SanDisk Cell Phone Accessories miniSDHC User Guide
Sanyo Digital Camera VPC SX 550 User Guide
Saturn Automobile 2007 Relay User Guide