899750 - 02-14-02.qxd 9/24/02 7:42 AM Page 1
ESPAÑOL: PÁGINA 15
FRANÇAISE : PAGE 29
Double Insulated
Routers
Instruction
manual
MODEL 7518
Consisting of:
MODEL 75182 Motor
MODEL 75361 Base
MODEL 7519
Consisting of:
MODEL 75192 Motor
MODEL 75361 Base
IMPORTANT
Please make certain that the person who is
to use this equipment carefully reads and
understands these instructions before
starting operations.
To learn more about Porter-Cable
visit our website at:
The Model and Serial No. plate is located on the main
housing of the tool. Record these numbers in the
spaces below and retain for future reference.
Model No. ______________________________________
Type ___________________________________________
Serial No._______________________________________
Part No. 899750 - 02-14-02
Copyright © 2002 Porter-Cable Corporation
Download from Www.Somanuals.com. All Manuals Search And Download.
899750 - 02-14-02.qxd 9/24/02 7:42 AM Page 3
2. Dress properly. Do not wear loose clothing or jewelry. Contain long
hair. Keep your hair, clothing, and gloves away from moving parts.
Loose clothes, jewelry, or long hair can be caught in moving parts.
3. Avoid accidental starting. Be sure switch is OFF before plugging in.
Carrying tools with your finger on the switch or plugging in tools that have
the switch ON invites accidents.
4. Remove adjusting keys or wrenches before turning the tool ON. A
wrench or a key that is left attached to a rotating part of the tool may result in
personal injury.
5. Do not overreach. Keep proper footing and balance at all times.
Proper footing and balance enable better control of the tool in unexpected
situations.
6. Use safety equipment. Always wear eye protection. Dust mask, non-
skid safety shoes, hard hat, or hearing protection must be used for
appropriate conditions.
TOOLS USE AND CARE
1. Use clamps or other practical way to secure and support the
workpiece to a stable platform. Holding the work by hand or against your
body is unstable and may lead to loss of control.
2. Do not force tool. Use the correct tool for your application. The
correct tool will do the job better and safer at the rate for which it is
designed.
3. Do not use tool if switch does not turn it ON or OFF. A tool that
cannot be controlled with the switch is dangerous and must be repaired.
4. Disconnect the plug from the power source before making any
adjustments, changing accessories, or storing the tool. Such preventive
safety measures reduce the risk of starting the tool accidentally.
5. Store idle tools out of reach of children and other untrained
persons. Tools are dangerous in the hands of untrained users.
6. Maintain tools with care. Keep cutting tools sharp and clean.
Properly maintained tools, with sharp cutting edges are less likely to bind
and are easier to control.
7. Check for misalignment or binding of moving parts, breakage of
parts, and any other condition that may affect the tool’s operation. If
damaged, have the tool serviced before using. Many accidents are
caused by poorly maintained tools.
8. Use only accessories that are recommended by the manufacturer
for your model. Accessories that may be suitable for one tool may become
hazardous when used on another tool.
SERVICE
1. Tool service must be performed only by qualified repair personnel.
Service or maintenance performed by unqualified personnel may result in a
risk of injury.
2. When servicing a tool, use only identical replacement parts. Follow
instructions in the Maintenance Section of this manual. Use of
unauthorized parts or failure to follow Maintenance Instructions may create a
risk of electric shock or injury.
SAVE THESE INSTRUCTIONS
3
Download from Www.Somanuals.com. All Manuals Search And Download.
899750 - 02-14-02.qxd 9/24/02 7:42 AM Page 4
SPECIFIC SAFETY RULES AND SYMBOLS FOR ROUTERS
1. HOLD TOOL BY INSULATED GRIPPING SURFACES WHEN
PERFORMING AN OPERATION WHERE THE CUTTING TOOLS MAY
CONTACT HIDDEN WIRING OR ITS OWN CORD. Contact with a “live”
wire will make exposed metal parts of the tool “live” and shock the
operator.
2. TIGHTEN COLLET NUT SECURELY to prevent the bit from slipping.
3. PROVIDE CLEARANCE under workpiece for router bit when through-
cutting.
4. CHECK TO SEE THAT THE CORD will not “hang up” during operation.
5. CLEAR THE ROUTER BIT AREA before starting motor.
6. MAINTAIN FIRM GRIP ON TOOL to resist starting torque.
7. KEEP HANDS CLEAR OF BIT WHEN MOTOR IS RUNNING to prevent
personal injury.
8. LET THE MOTOR COME TO A COMPLETE STOP before putting the
tool down.
9. NEVER TOUCH ROUTER BITS AFTER USE. They may be extremely
hot.
10. AVOID “CLIMB-CUTTING”. (See section “USING THE ROUTER” in this
manual). “Climb-cutting” increases the chance for loss of control resulting
in possible personal injury.
11. DO NOT HAND-HOLD THE ROUTER IN AN UPSIDE-DOWN OR
HORIZONTAL POSITION. The motor can separate from the base if
not properly attached according to the instructions (See
"ATTACHING THE MOTOR TO THE ROUTER") section.
12. SOME WOOD CONTAINS PRESERVATIVES WHICH CAN BE TOXIC.
Take extra care to prevent inhalation and skin contact when working
with these materials. Request, and follow, any safety information
available from your material supplier.
13.
WARNING: There are certain applications for which this tool was
designed. Porter-Cable strongly recommends that this tool NOT be
modified and/or used for any application other than that for which it was
designed. If you have questions relative to its application, DO NOT use
the tool until you have written Porter-Cable and we have advised you.
Technical Service Manager
Porter-Cable Corporation
4825 Highway 45 North
Jackson, TN 38305
4
Download from Www.Somanuals.com. All Manuals Search And Download.
899750 - 02-14-02.qxd 9/24/02 7:43 AM Page 5
SYMBOL
DEFINITION
........................ volts
V
A
........................ amperes
........................ hertz
........................ watts
........................ kilowatts
........................ microfarads
........................ liters
Hz
W
kW
µF
l
kg
........................ kilograms
N/cm2 ........................ newtons per square centimeter
Pa
h
min
s
........................ pascals
........................ hours
........................ minutes
........................ seconds
........................ alternating current
3
........................ three-phase alternating current
3N
........................ three-phase alternating current with neutral
........................ direct current
........................ no load
n0
........................ alternating or direct current
........................ Class II Construction
........................ splash-proof construction
........................ watertight construction
…/min ........................ revolutions or reciprocation per minute
REPLACEMENT PARTS
When servicing use only identical replacement parts.
MOTOR
Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60
cycle A.C. current and voltage within plus or minus 5 percent of that shown
on the specification plate on the tool. Several models, however, are designed
for A.C. current only. Refer to the specification plate on your tool for proper
voltage and current rating.
CAUTION: Do not operate your tool on a current on which the
voltage is not within correct limits. Do not operate tools rated A.C.
only on D.C. current. To do so may seriously damage the tool.
EXTENSION CORD SELECTION
If an extension cord is used, make sure the conductor size is large enough to
prevent excessive voltage drop which will cause loss of power and possible
motor damage. A table of recommended extension cord sizes will be found
in this section. This table is based on limiting line voltage drop to 5 volts (10
volts for 230 volts) at 150% of rated amperes.
If an extension cord is to be used outdoors it must be marked with the suffix
W-A or W following the cord type designation. For example – SJTW-A to
indicate it is acceptable for outdoor use.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
899750 - 02-14-02.qxd 9/24/02 7:43 AM Page 6
RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS
Length of Cord in Feet
115V
230V
25 Ft.
50 Ft.
50 Ft.
100 Ft. 150 Ft. 200 Ft.
250 Ft. 300 Ft.
500 Ft. 600 Ft.
400 Ft. 500 Ft.
800 Ft. 1000 Ft.
100 Ft. 200 Ft. 300 Ft. 400 Ft.
0-2
2-3
18
18
18
18
18
18
18
16
16
16
14
14
18
18
18
18
16
16
14
14
12
12
12
12
18
16
16
14
14
12
12
10
10
10
8
16
14
14
12
12
10
10
8
16
14
12
12
10
10
8
14
12
12
10
10
8
14
12
10
10
8
12
10
10
8
12
10
8
3-4
4-5
8
5-6
8
6
6-8
6
6
6
8-10
10-12
12-14
14-16
16-18
18-20
8
6
6
4
8
6
6
4
4
8
6
6
6
4
2
8
6
6
4
4
2
8
6
4
4
2
2
8
6
6
4
4
2
2
FUNCTIONAL DESCRIPTION
FOREWORD
Model 7518 Porter-Cable Router incorporates a speed control that provides
operating speeds from 10,000 RPM to 21,000 RPM, to handle the most
demanding router applications in various materials.
Model 7519 Porter-Cable Router is designed for continuous, rugged
operations to handle the most demanding routing applications at 21,000
RPM.
SELECTING THE BIT
Models 7518 and 7519 accommodate bits with 1/2" diameter shanks that are
installed directly into the power unit collet. Collets are available that will allow
the use of bits having 1/4" or 3/8" diameter shanks.
CAUTION: DO NOT USE router bits with a diameter in excess of
21/2" except when using Model 75182 motor set for either 10,000 or
13,000 RPM. Router bits with a diameter up to 3" may be used with
the 75182 motor operating in the 10,000 or 13,000 RPM speeds.
Router bits with a diameter up to 31/2" may be used with the 75182
motor operating in the 10,000 RPM speed.
B
A
Fig. 1
6
Download from Www.Somanuals.com. All Manuals Search And Download.
899750 - 02-14-02.qxd 9/24/02 7:43 AM Page 7
CAUTlON: While preparing the router for use, while making
adjustments, and when router is not in use, ALWAYS DISCONNECT
IT FROM THE POWER SOURCE.
Fig. 2
ASSEMBLY
INSTALLING AND REMOVING THE BIT
1. CAUTION: DISCONNECT TOOL FROM POWER SOURCE.
2. Remove motor unit from base unit as follows:
(a) Loosen clamp screw (A), Fig. 1.
(b) While holding base, turn motor unit COUNTERCLOCKWISE until
lower pin (B) in motor housing is disengaged from groove in base.
(c) Lift motor unit free from base unit.
3. Clean and insert shank of bit into collet at least 3/4". If shank “bottoms” in
router, then back it out approximately 1/16" to allow proper tightening.
4. Lay motor unit on its side on bench with the collet pointing AWAY from
you.
5. Place one wrench on flats on chuck with the opposite end of the wrench
resting on the bench to your left, Fig. 2.
6. Place other wrench on collet and tighten COUNTERCLOCKWISE as
shown in Fig. 2. TIGHTEN SECURELY.
7. To remove the bit, reverse the foregoing procedure. If bit does not
remove easily, tap the collet nut with wrench to release.
AVOID POSSIBLE DAMAGE TO COLLET.
NEVER TIGHTEN COLLET WITHOUT BIT.
ASSEMBLING THE MOTOR IN THE ROUTER BASE
1. CAUTION: DISCONNECT TOOL FROM POWER SOURCE.
2. Loosen the clamp screw (A), Fig. 1, to allow the power unit to be set in
the base unit.
3. Insert motor unit into base aligning lower pin (B) with groove in base.
4. Rotate motor unit CLOCKWISE into base until upper guide pins are
rigidly set in the groove of the base.
5. Tighten clamp screw firmly.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
899750 - 02-14-02.qxd 9/24/02 7:43 AM Page 8
ADJUSTING DEPTH OF CUT
1. CAUTION: DISCONNECT TOOL FROM POWER SOURCE.
F
B
D
E
C
A
Fig. 3
2. Loosen clamp screw (A) Fig. 3.
3. While holding base (E), turn motor unit (F), Fig. 3, COUNTERCLOCKWISE
until the tip of the bit is above bottom surface of base.
4. Set router on flat wood surface.
5. Turn motor unit (F), Fig. 3, CLOCKWISE until bit touches the wood
surface.
6. Tighten clamp screw (A) Fig. 3.
7. Rotate depth adjusting ring (B), Fig. 3, until the zero-line (C) is opposite
the index line (D) on the housing.
8. Loosen clamp screw (A), Fig. 3.
9. Tip the router so bit is clear of the wood surface. Turn motor unit (F),
Fig. 3, CLOCKWISE until the index line (D) on the motor housing reaches the
desired depth indicated on the ring.
10. Tighten clamp screw (A), Fig. 3, firmly.
1
NOTE: Setting the index line to /4" on the ring means the cutting
edge of the bit is exposed 1/4" below the base.
CONNECTING TO POWER SOURCE
CAUTION: Before connecting router to power source ALWAYS
MAKE SURE SWITCH IS IN THE “OFF” POSITION. Also check that
the power circuit is the same as that shown on specification plate of
the router.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
899750 - 02-14-02.qxd 9/24/02 7:43 AM Page 9
OPERATION
TO START AND STOP ROUTER
CAUTION: Before starting the router make sure bit is clear of
workpiece and foreign objects. Also keep firm grip on router to resist
starting torque.
The router is started and stopped by depressing the rocker switch (A), Fig. 4,
into the ON or OFF position.
CAUTION: To avoid personal injury or damage to finished work
always allow the motor to come to a COMPLETE STOP before
setting it down.
MODEL 7518
MODEL 7519
B
A
A
Fig. 4
OVERLOAD PROTECTION
Model 7518 is equipped with an overload protector that will shut motor off if
prolonged overload conditions are encountered.
If the motor stops during use: (1) depress rocker switch (A), Fig. 4, into the
OFF position; (2) determine cause of overload (i.e. dull bit, low voltage,
excessive feed rate, etc.) and correct before continuing; (3) restart router
following the instructions in TO START AND STOP ROUTER.
Model 7519 is equipped with a thermal-type circuit breaker incorporated into
the ON/OFF rocker switch (A), Fig. 4. This circuit breaker will turn the switch
OFF if prolonged overload conditions are encountered.
If the circuit breaker “trips”, switching the motor OFF: (1) determine cause of
the overload (i.e. dull bit, low voltage, excessive feed rate, etc.) and correct
before continuing; (2) allow router to cool for three minutes; and, (3) restart
router following the instructions in TO START AND STOP ROUTER.
SOFT START
Model 7518 and 7519 have a “Soft Start” feature designed to minimize
startup reaction torque.
SPEED CONTROL (Model 7518 only)
The speed control is located as shown in Fig. 4. Five operating speeds from
10,000 RPM to 21,000 RPM are available by moving the speed selector knob
(B), Fig. 4. It is recommended that the speed be set prior to engaging the
router bit into work. Should it be necessary to change the speed after work
has begun, stop router, remove router clear of work, and adjust speed
setting.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
899750 - 02-14-02.qxd 9/24/02 7:43 AM Page 10
USING THE ROUTER
IMPORTANT: Before using your router, consider the kind and total
amount of material to be removed. Depending on the material, it may
be necessary to make more than one cut to avoid overloading the
motor. Before beginning the cut on the actual workpiece, it is
advisable to make a sample cut on a piece of scrap lumber. This will
show exactly how the cut will look as well as enable you to check
dimensions.
CAUTION: Always be sure the work is rigidly clamped or otherwise
secured before making a cut.
Generally speaking, when working on a bench, the workpiece should be held
on the bench by wood clamps. When routing edges, the router should be
held firmly down and against the work by both handles.
Since the cutter rotates clockwise (when viewing router from top), the router
should be moved from left to right as you stand facing the work (see Fig. 5).
When working on the inside of a templet, move router in clockwise direction.
When working on the outside of a templet, move router in a counterclockwise
direction.
WARNING: Avoid “Climb-Cutting”
(cutting in direction opposite that
shown in Fig. 5), “Climb-Cutting”
increases the chance for loss of
control resulting in possible personal
injury. When “Climb-Cutting” is
required (backing around a corner),
exercise extreme caution to maintain
control of router.
Fig. 5
The speed and depth of cut will depend largely on the type of material being
worked upon. Keep the cutting pressure constant but do not crowd the
router so the motor speed slows excessively. It may be necessary on
exceptionally hard woods or problem materials to make more than one pass
at various settings to get the desired depth of cut.
When making cuts on all four edges of the workpiece, it is advisable to have
the first cut on the end of the piece across the grain. Thus, if chipping of
wood occurs at the end of a cut, it will be removed when making the next cut
parallel with the grain.
THE EDGE GUIDE
An edge guide is available as an accessory to aid in routing operations such
as: straight edge planing, parallel grooving, dado or slotting operations.
To assemble, insert guide rods (A) in holes in base, Fig. 6, and secure with
screws (B). The guide (C) is adjusted on the rods and secured in desired
position with thumb screws (D).
10
Download from Www.Somanuals.com. All Manuals Search And Download.
899750 - 02-14-02.qxd 9/24/02 7:43 AM Page 11
B
B
C
D
D
A
Fig. 6
TEMPLET GUIDES
A wide variety of templet guides are available for use in pattern and templet
routing operations. Fig. 7 shows a typical combination bit, templet guide, and
locknut.
CAUTION: DISCONNECT TOOL FROM POWER SOURCE.
To install, insert templet guide in center hole in router base and secure in
place with the locknut.
BEFORE CONNECTING ROUTER TO POWER SOURCE: Install, bit, adjust
depth of cut, and rotate router chuck by hand to be sure bit or collet do not
contact templet guide.
BASE
LOCKNUT
SUB-BASE
ROUTER BIT
TEMPLET GUIDE
Fig. 7
11
Download from Www.Somanuals.com. All Manuals Search And Download.
899750 - 02-14-02.qxd 9/24/02 7:43 AM Page 12
MAINTENANCE
KEEP TOOL CLEAN
Periodically blow out all air passages with dry compressed air. All plastic
parts should be cleaned with a soft damp cloth. NEVER use solvents to
clean plastic parts. They could possibly dissolve or otherwise damage the
material.
CAUTION: Wear safety glasses while using compressed air.
FAILURE TO START
Should your tool fail to start, check to make sure the prongs on the cord
plug are making good contact in the outlet. Also, check for blown fuses or
open circuit breakers in the line.
LUBRICATION
This tool has been lubricated with a sufficient amount of high grade
lubricant for the life of the unit under normal operating conditions. No further
lubrication is necessary.
BRUSH INSPECTION AND LUBRICATION
For your continued safety and electrical protection, brush inspection and
replacement on this tool should ONLY be performed by an AUTHORIZED
PORTER-CABLE SERVICE STATION or a PORTER-CABLE/DELTA
FACTORY SERVICE CENTER.
At approximately 100 hours of use, take or send your tool to your nearest
authorized Porter-Cable Service Station to be thoroughly cleaned and
inspected. Have worn parts replaced and lubricate with fresh lubricant. Have
new brushes installed, and test the tool for performance.
Any loss of power before the above maintenance check may indicate the
need for immediate servicing of your tool. DO NOT CONTINUE TO
OPERATE TOOL UNDER THIS CONDITION. If proper operating voltage is
present, return your tool to the service station for immediate service.
SERVICE AND REPAIRS
All quality tools will eventually require servicing or replacement of parts due
to wear from normal use. These operations, including brush inspection and
replacement, should ONLY be performed by either an AUTHORIZED
PORTER-CABLE SERVICE STATION or a PORTER-CABLE/DELTA
FACTORY SERVICE CENTER. All repairs made by these agencies are fully
guaranteed against defective material and workmanship. We cannot
guarantee repairs made or attempted by anyone other than these agencies.
Should you have any questions about your tool, feel free to write us at any
time. In any communications, please give all information shown on the
nameplate of your tool (model number, type, serial number, etc.).
12
Download from Www.Somanuals.com. All Manuals Search And Download.
899750 - 02-14-02.qxd 9/24/02 7:43 AM Page 13
ACCESSORIES
A complete line of accessories is available from your Porter-Cable •
Delta Supplier, Porter-Cable • Delta Factory Service Centers, and
Porter-Cable Authorized Service Stations. Please visit our Web Site
www.porter-cable.com for a catalog or for the name of your nearest
supplier.
WARNING: Since accessories other than those offered by Porter-Cable
• Delta have not been tested with this product, use of such accessories
could be hazardous. For safest operation, only Porter-Cable • Delta
recommended accessories should be used with this product.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
899750 - 02-14-02.qxd 9/24/02 7:43 AM Page 14
PORTER-CABLE LIMITED
ONE YEAR WARRANTY
Porter-Cable warrants its Professional Power Tools for a period of one year from the date of original
purchase. We will repair or replace at our option, any part or parts of the product and accessories
covered under this warranty which, after examination, proves to be defective in workmanship or
material during the warranty period. For repair or replacement return the complete tool or accessory,
transportation prepaid, to your nearest Porter-Cable Service Center or Authorized Service Station.
Proof of purchase may be required. This warranty does not apply to repair or replacement required
due to misuse, abuse, normal wear and tear or repairs attempted or made by other than our Service
Centers or Authorized Service Stations.
ANY IMPLIED WARRANTY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, WILL LAST ONLY FOR ONE (1) YEAR FROM THE DATE
OF PURCHASE.
To obtain information on warranty performance please write to: PORTER-CABLE CORPORATION,
4825 Highway 45 North, Jackson, Tennessee 38305; Attention: Product Service. THE FOREGOING
OBLIGATION IS PORTER-CABLE’S SOLE LIABILITY UNDER THIS OR ANY IMPLIED WARRANTY
AND UNDER NO CIRCUMSTANCES SHALL PORTER-CABLE BE LIABLE FOR ANY INCIDENTAL
OR CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how long an implied
warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other legal rights which vary
from state to state.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
899750 - 02-14-02.qxd 9/24/02 7:43 AM Page 44
PORTER-CABLE • DELTA SERVICE CENTERS
(CENTROS DE SERVICIO DE PORTER-CABLE • DELTA)
(CENTRE DE SERVICE PORTER-CABLE • DELTA)
Parts and Repair Service for Porter-Cable
(Obtenga Refaccion de Partes o Servicio para su Herramienta en los Siguientes Centros de Porter-Cable
(Locations où vous trouverez les pièces de rechange nécessaires ainsi qu’un service d’entretien)
•
Delta Power Tools are Available at These Locations
•
Delta)
ARIZONA
ILLINOIS
MINNESOTA
Cleveland 44125
Tempe 85282 (Phoenix)
2400 West Southern Avenue
Suite 105
Phone: (602) 437-1200
Fax: (602) 437-2200
Addison 60101 (Chicago)
311 Laura Drive
Phone: (630) 628-6100
Fax: (630) 628-0023
Minneapolis 55429
8001 Sweet Valley Drive Unit #19
Phone: (216) 447-9030
Fax: (216) 447-3097
5522 Lakeland Avenue North
Phone: (763) 561-9080
Fax: (763) 561-0653
OREGON
Woodridge 60517 (Chicago)
2033 West 75th Street
Phone: (630) 910-9200
Fax: (630) 910-0360
MISSOURI
Portland 97230
CALIFORNIA
North Kansas City 64116
1141 Swift Avenue
P.O. Box 12393
Phone: (816) 221-2070
Fax: (816) 221-2897
4916 NE 122 nd Ave.
Phone: (503) 252-0107
Fax: (503) 252-2123
Ontario 91761 (Los Angeles)
3949A East Guasti Road
Phone: (909) 390-5555
Fax: (909) 390-5554
MARYLAND
PENNSYLVANIA
Elkridge 21075 (Baltimore)
7397-102 Washington Blvd.
Phone: (410) 799-9394
Fax: (410) 799-9398
Willow Grove 19090
520 North York Road
Phone: (215) 658-1430
Fax: (215) 658-1433
San Leandro 94577 (Oakland)
3039 Teagarden Street
Phone: (510) 357-9762
Fax: (510) 357-7939
St. Louis 63119
7574 Watson Road
Phone: (314) 968-8950
Fax: (314) 968-2790
MASSACHUSETTS
Braintree 02185 (Boston)
719 Granite Street
Phone: (781) 848-9810
Fax: (781) 848-6759
TEXAS
FLORIDA
NEW YORK
Carrollton 75006 (Dallas)
1300 Interstate 35 N, Suite 112
Phone: (972) 446-2996
Fax: (972) 446-8157
Davie 33314 (Miami)
4343 South State Rd. 7 (441)
Unit #107
Phone: (954) 321-6635
Fax: (954) 321-6638
Flushing 11365-1595 (N.Y.C.)
175-25 Horace Harding Expwy.
Phone: (718) 225-2040
Fax: (718) 423-9619
Franklin 02038 (Boston)
Franklin Industrial Park
101E Constitution Blvd.
Phone: (508) 520-8802
Fax: (508) 528-8089
Houston 77055
NORTH CAROLINA
Charlotte 28270
9129 Monroe Road, Suite 115
Phone: (704) 841-1176
Fax: (704) 708-4625
West 10 Business Center
1008 Wirt Road, Suite 120
Phone: (713) 682-0334
Fax: (713) 682-4867
Tampa 33609
4538 W. Kennedy Boulevard
Phone: (813) 877-9585
Fax: (813) 289-7948
MICHIGAN
WASHINGTON
GEORGIA
Madison Heights 48071 (Detroit)
30475 Stephenson Highway
Phone: (248) 597-5000
Fax: (248) 597-5004
OHIO
Auburn 98001 (Seattle)
3320 West Valley HWY, North
Building D, Suite 111
Phone: (253) 333-8353
Fax: (253) 333-9613
Forest Park 30297 (Atlanta)
5442 Frontage Road, Suite 112
Phone: (404) 608-0006
Fax: (404) 608-1123
Columbus 43214
4560 Indianola Avenue
Phone: (614) 263-0929
Fax: (614) 263-1238
Authorized Service Stations are located in many large cities. Telephone 800-487-8665 or 731-541-6042 for assistance locating one.
Parts and accessories for Porter-Cable Delta products should be obtained by contacting any Porter-Cable Delta Distributor,
Authorized Service Center, or Porter-Cable Delta Factory Service Center. If you do not have access to any of these, call 888-848-5175
and you will be directed to the nearest Porter-Cable Delta Factory Service Center. Las Estaciones de Servicio Autorizadas están
ubicadas en muchas grandes ciudades. Llame al 800-487-8665 ó al 731-541-6042 para obtener asistencia a fin de localizar una. Las
piezas y los accesorios para los productos Porter-Cable Delta deben obtenerse poniéndose en contacto con cualquier distribuidor
Porter-Cable Delta, Centro de Servicio Autorizado o Centro de Servicio de Fábrica Porter-Cable Delta. Si no tiene acceso a ninguna
de estas opciones, llame al 888-848-5175 y le dirigirán al Centro de Servicio de Fábrica Porter-Cable Delta más cercano. Des centres
de service agréés sont situés dans beaucoup de grandes villes. Appelez au 800-487-8665 ou au 731-541-6042 pour obtenir de l’aide
pour en repérer un. Pour obtenir des pièces et accessoires pour les produits Porter-Cable Delta, s’adresser à tout distributeur Porter-
Cable Delta, centre de service agréé ou centre de service d’usine Porter-Cable Delta. Si vous n’avez accès à aucun de ces centres,
appeler le 888-848-5175 et on vous dirigera vers le centre de service d’usine Porter-Cable Delta le plus proche.
•
•
•
•
•
•
•
•
•
•
•
•
CANADIAN PORTER-CABLE • DELTA SERVICE CENTERS
QUÉBEC
ALBERTA
MANITOBA
1515 Ave.
Bay 6, 2520-23rd St. N.E.
Calgary, Alberta
T2E 8L2
1699 Dublin Avenue
Winnipeg, Manitoba
R3H 0H2
St-Jean Baptiste,
Québec, Québec
G2E 5E2
Phone: (418) 877-7112
Fax: (418) 877-7123
Phone: (403) 735-6166
Fax: (403) 735-6144
Phone: (204) 633-9259
Fax: (204) 632-1976
BRITISH COLUMBIA
8520 Baxter Place
Burnaby, B.C.
V5A 4T8
Phone: (604) 420-0102
Fax: (604) 420-3522
ONTARIO
1447, Begin
St-Laurent, (Montréal), Québec
H4R 1V8
Phone: (514) 336-8772
Fax: (514) 336-3505
505 Southgate Drive
Guelph, Ontario
N1H 6M7
Phone: (519) 836-2840
Fax: (519) 767-4131
The following are trademarks of PORTER-CABLE
•
DELTA (Las siguientes son marcas registradas de PORTER-CABLE
•
DELTA S.A.) (Les
marques suivantes sont des marques de fabriquant de la PORTER-CABLE
•
DELTA): BAMMER®, LASERLOC®, OMNIJIG®, POCKET CUTTER®,
PORTA-BAND®, PORTA-PLANE®, PORTER-CABLE®, QUICKSAND®, SANDTRAP®, SAW BOSS®, SPEED-BLOC®, SPEEDMATIC®,
SPEEDTRONIC®, STAIR-EASE®, THE PROFESSIONAL EDGE®, THE PROFESSIONAL SELECT®, TIGER CUB®, TIGER SAW®, TORQ-BUSTER®,
VERSA-PLANE®, WHISPER SERIES®, DURATRONIC™, FRAME SAW™, INNOVATION THAT WORKS™, JETSTREAM™, MICRO-SET™,
MORTEN™, NETWORK™, RIPTIDE™, TRU-MATCH™, WOODWORKER’S CHOICE™, THE AMERICAN WOOD SHOP™ (design) , AUTO-
SET™, B.O.S.S.™, BUILDER’S SAW™, CONTRACTOR’S SAW™, DELTA™, DELTACRAFT™, HOMECRAFT™, JET-LOCK™, KICKSTAND™,
THE LUMBER COMPANY™ (design). MICRO-SET™, Q3™, QUICKSET II™, QUICKSET PLUS™, SAFEGUARD II™, SANDING CENTER™,
SIDEKICK™, UNIFENCE™, UNIGUARD™, UNIRIP™, UNISAW™, VERSA-FEEDER™ , TPS™, Emc²™.
Trademarks noted with ™ and ® are registered in the United States Patent and Trademark Office and may also be registered in other
countries. Las Marcas Registradas con el signo de ™ y ® son registradas por la Oficina de Registros y Patentes de los Estados Unidos y
también pueden estar registradas en otros países. Marques déposées, indiquées par la lettre ™ et ®, sont déposées au Bureau des brevets
d’invention et marques déposées aux Etats-Unis et pourraient être déposées aux autres pays.
Printed in U.S.A.
Download from Www.Somanuals.com. All Manuals Search And Download.
|