A470 IMPACT
VALIDATION
PRINTER
Pertech
®
�
Users Guide
220117B-03 3/06
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Disclaimer
Information in this document is subject to change without notice. Consult your Pertech® sales representative for information
that is applicable and current. Pertech reserves the right to improve products as new technology, components, software and
firmware become available.
No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any
purpose with out the express written permission of Pertech.
Copyright
Copyright © 2005 by Pertech Resources, Inc..
Riverton, Wyoming USA
All rights reserved
Printed in USA
Confidential, Unpublished
Property of Pertech Resources, Inc.
Trademarks
PERTECH® is a registered trademark of PERTECH RESOURCES, INC.
Other trademarks and registered trademarks are the property of their respective holders
Web site
Federal Communications Commission (FCC) Radio
Frequency Interference Statement
Warning
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the
FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and , if
not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Information to the User
This equipment must be installed and used in strict accordance with the manufacturer’s instructions. However, there is no
guarantee that interference of radio communications will not occur in a particular commercial installation. If this equipment
does cause interference, which can be determined by turning the equipment off and on , the user is encouraged to contact
Pertech immediately.
Pertech is not responsible for any radio of television interference caused by unauthorized modification of this equipment, or
the substitution of attachment or connection cables and equipment other than those specified by Pertech. The correction of
interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.
Industry Canada
This Class A digital apparatus complies with Industry Canada Standard ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 d’Industrie Canada.
Pertech® 2006
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Important Information to the User
In order to ensure compliance with the Product Safety, FCC, and CE marking requirements, you must use the power supply,
power cord, and interface cable, which were shipped with this product or which meet the following parameters:
Power Supply
Input power to this product must be provided by one of the following:
(1) A NRTL Certified power source with a Limited Power Source.
(LPS) output for use in North America, input rated 100-240 Vac, 1.5 A, 50/60 Hz, output rated 24 Vdc at 2.5 A. Maximum and
60W Maximum, or
(2) A Power source with a Limited Power Source (LPS) output Certified by an agency recognized in the country of installation,
input rated 100-240 Vac, 1.5 A, 50/60 Hz, output rated 24 Vdc at 2.5 A. Maximum and 60W Maximum.
Use of this product with a power supply other than the Pertech power supply will require you to test this power supply and
Pertech printer for FCC and CE mark certification.
Interface Cable
A shielded (360 degree) interface cable must be used with this product. The shield must be connected to the frame or earth
ground connection or earth ground reference at EACH end of the cable.
Use of a cable other than described here will require that you test this cable with the Pertech printer and your system for FCC
and CE mark certification.
Power Cord
For North America a NRTL recognized detachable power cord must be used. For applications where the power supply module
may be located on the floor, a power cord with Type SJT marking must be used.
For applications outside North America, power cords which meet the country of installation’s certification and application
requirements must be used.
Use of a power cord other than described here may result in a violation of safety certifications which are in force in the country of
use.
Pertech® 2006
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Contents
Preface ...............................................................................................................vii
Chapter 1: About the Printer ..............................................................................1
Features and Options.................................................................................2
Paper: ............................................................................................3
Ribbons: ..........................................................................................3
Cables .............................................................................................3
Chapter 2: Operating the Printer........................................................................4
Paper Loading ............................................................................................5
Validation ....................................................................................................8
Adjustable Features....................................................................................8
Maintaining The Printer............................................................................. 11
Extended Self Test....................................................................................12
Configuring the Printer..............................................................................13
Pertech® 2006
v
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Chapter 4: Communication...............................................................................14
RS232 Serial Interface .............................................................................15
Parallel Interface.......................................................................................16
Cash Drawer.............................................................................................17
Power Supply ...........................................................................................17
Service...........................................................................................21
Appendix B: Specifications..............................................................................24
Operating..................................................................................................24
Environment .............................................................................................24
Media........................................................................................................24
Electrical ...................................................................................................25
Hardware ..................................................................................................25
Warranty.............................................................................................................29
Pertech® 2006
vi
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Preface
This manual has been written to help you install, operate and maintain your new Pertech A470 Printer. Feel
free to contact us if you need further assistance after reading this manual. Please see the Troubleshooting
Printer Problems section of this manual and determine the complete part number of your printer prior to
calling. Pertech provides technical support Monday through Friday from 8:00 AM to 5:00 PM MST at 307-
856-4821.
Every effort has been made to insure the information in this manual is complete and accurate. Feel free to
contact us with any comments concerning this manual. Pertech assumes no responsibility for errors.
Where to Get Additional information
The following publications contain more information about the A470 printer. Contact your Pertech sales
representative to obtain additional copies of this Owners Manual or any of the publications listed below.
Title
Part Number
220296
220117
220282
Available On Request
A470 Transaction Printer: Setup Guide
A470 Transaction Printer: Users Guide
A470 Transaction Printer: Programming Manual
A470 Transaction Printer: Parts Identification Manual
Pertech® 2006
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Chapter 1: About the Printer
The A470 printer is a fast reliable printer designed to meet your immediate and long term needs.
Industry standard RS-232 serial and 1284 compliant parallel interfaces allow for connection
to any host computer or terminal system .The A470 printer features a one button configuration
setup with five compatibility modes for easy integration into existing systems.
When you receive your new A470 printer it will be packed in impact resistant foam
packing. Remove the foam packing and anti static bag from the printer. The printer comes
with a auto ranging power supply and the setup guide. This Users Guide is available at
Pertech® 2006
1
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Features and Options
This manual covers several models and describes features and options which do not apply to all
versions. Refer to the model list below to determine which features your printer supports.
Standard Features:
Interfaces
RS-232Serial, 1284 Parallel.
Memory/Firmware
Resident Character Sets
Dual Cash Drawer
Paper Low Sensor
Form In Sensor
Flash Memory.
US, UK, French, German, Italian, Spanish, Hebrew
Connectors for two Cash Drawers.
(LED) indicator on front of printer.
Optional Left Right or Dual available from factory.
Configuration Dip switches, located on case bottom.
Easy Access Setup
Model specific features:
MODEL
4710
4711
REWIND
RECEIPT
VALIDATION
FEED TYPE *
CASE SIZE
LONG 11.54”
LONG 11.54”
LONG 11.54”
SHORT 8.3”
SHORT 8.3”
SHORT 8.3”
SHORT 8.3”
Y
Y
Y
N
N
N
N
Y
Y
Y
Y
Y
Y
N
N
Y
Y
N
Y
Y
Y
-
I
4712
4770
4771
4772
4774
C
-
I
C
-
* FEED TYPE:
I - Independent feed printers provide either roll paper or validation media feed at
any given time depending on which print mode has been selected. This feature
saves roll paper media during validation printing.
C - Concurrent feed printers provide both roll paper and validation media feed at
the same time. This feature provides a roll paper copy of the printed validation
message when self-contained roll paper is used. Validation media is not required
for normal roll paper printing.
V - Validation only printers do not support roll paper printing functions.
Pertech® 2006
2
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Ordering Paper and Supplies
The following section lists the paper and supplies available for order. In addition to paper
and ribbons, parts, service and repair may be obtained by calling 800-800-6614.
Paper:
Paper Ply
Part Number
One ............................................................................................................103292016
Two ............................................................................................................103292017
Three .........................................................................................................103292021
Ribbons:
Description
Part Number
Standard Life Ribbon
Purple ink.......................................................................................105109001
Black Ink........................................................................................105109002
Long Life Ribbon
Purple Ink ......................................................................................105109008
Black ink ........................................................................................105109006
Purple Ink -- Black Case................................................................105108001
Black ink -- Black Case..................................................................105108002
Cables
Description
Part Number
Adapter RS232 DB9F TO RJ45F Serial........................................................ 106356005
Cable 48” RJ45M to RJ45M ......................................................................... 106155002
Cable 120”” RJ45M to RJ45M ...................................................................... 106155003
Documentation:
Title
Part Number
A470 Transaction Printer: Setup Guide ....................................................... 220296
A470 Transaction Printer: Users Guide ........................................................ 220117
A470 Transaction Printer: Programming Manuals ....................................... 220282
A470 Transaction Printer: Parts Identification Manuals.......... Available On Request
Pertech® 2006
3
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Chapter 2: Operating the Printer
This chapter describes the printer controls and provides procedures for loading
Paper and Ribbons . Additionally, the adjustment procedures for setting the Air Gap,
Document Stop and Low Paper Sensor are provided,
Using the Controls
The A470 printer includes the following controls:
Paper feed button used to advance paper
Power switch used to turn the printer on and off
The A470 also includes a Slow Down mode which prevents damage to the printer by reducing
the print speed during long periods of continuous printing. The printhead automatically returns
to normal speed when usage returns to normal. Do not cycle the printer power or Reset the
printer while in Slow Down mode or damage could result.
Pertech® 2006
4
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Paper Loading
Roll paper must be 3.25 inches wide with a maximum diameter of 3.5 inches. Receipt / Journal
printers can accommodate 1, 2 or 3 ply paper. Paper and other printer consumables may be
purchased from Pertech by calling 1-800-800-6614.
To load paper the power must be turned ON. Refer to the pictorial paper loading instructions in
the lid of the printer. Specific steps may vary depending on the printer configuration. Follow the
instructions on this page for model 477X printers. Use the following page for 471X models.
Failure to load paper correctly may result in a paper jam.
To remove paper that has jammed, it is advisable to:
1) Tear off any paper that fed out of the top of the
mechanism
2) Press downward on the metal release bracket
3) While pulling the remaining paper out of the
mechanism backwards
477X Paper Loading Instructions
2 Insert the leading
edge of the paper
into the roller on
the black block.
1 Raise cover and
remove the spent
roll. Insert the new
roll so the paper
exits from the
bottom of the roll
3 Press and hold
downward on
the green paper
loading button...
4 ... Until six inches
of paper exits from
the mechanism.
5 Insert the paper
through the receipt
slot and lower the
cover
Pertech® 2006
5
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
471X Paper Loading Instructions
1. Raise cover
and remove the
spent roll. Flip
the green paper
loading chute
to the raised
position.
2. Install the new
roll so the paper
exits from the
bottom of the roll.
3. Insert the
leading edge of
the paper into
the green loading
chute.
4. Press and hold
downward on the
green paper loading
button ...
5. ... Until one
foot of paper
exits from the
mechanism
6. Flip the green
paper loading chute
to the lowered
position.
7. Separate the
paper plies if
more than one ply
is used.
8. Fold and insert
the leading edge of
the back ply into the
rewind spool slot.
Rotate as shown to
wind up slack.
9. Replace the
rewind spool in
the printer and
snap into place.
10. Insert the
receipt ply through
the receipt slot and
lower the cover.
Pertech® 2006
6
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Ribbon Cartridge Replacement
To replace the ribbon raise the printer cover. Leave the printer power on. Press on the Ribbon
Interlock Tab and ribbon will disengage from the innerframe. Lift the old Ribbon Cartridge up
and out of the printer and discard. Remove new cartridge from the plastic bag and rotate the
advance tab until all slack is removed. Align the new cartridge so the exposed ribbon is between
the printhead guide and the first silver roller. Lower the cartridge into place. Do not turn the
advance tab after the cartridge has been installed. Close the printer cover.
Ribbon Interlock Tab
Ribbon Advance
CAUTION: METAL SURFACES OF PRINTHEAD MAY BE HOT - AVOID CONTACT! Call 1-
800-800-6614 to order replacement ribbon cartridges.
Pertech® 2006
7
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Validation
A Validation Form can be inserted from the top or top and left once the clamp has opened. The
printer will automatically clamp the form when it has been detected. Wait until the printer has
finished printing and released the form prior to removal.
Adjustable Features
Air Gap Adjustment
The air gap may need adjustment if 3 ply roll paper is used. If adjustment is required it will be
evidenced by ink smudge on a Self Test printout. Most 3 ply paper can be accommodated by
turning the 2 adjustment screws clockwise 1/8 of a turn.
CAUTION: Metal surfaces of
printhead may be hot - avoid
contact! The air gap is the
distance between the print head
and the print bar. This space must
be large enough to accommodate
the ribbon material and the print
media. Too great an air gap will
cause light print or missing dots
and too small an air gap will
produce ink smudge on the media.
The air gap can be changed by
turning the 5/64 hex socket drive
screws near each end of the print
bar. These screws are visible
5/64 Adjustment Screws
once the cover is raised and
the ribbon cartridge is removed.
Clockwise adjustment will increase
the air gap and counter-clockwise
adjustment will decrease the air
gap.
Pertech® 2006
8
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Document Stop Adjustment
The Document Stop limits the depth an inserted form can be placed into the Validation Slot. This
defines the validation printfield height. Printers are manufactured with the maximum printfield
setting of 2.16 inches but the dimension can be reduced to 1.44 inches by turning a slotted
screw in the bottom of the printer case counter-clockwise (CCW). Each CCW revolution raises
the document stop and decreases the printfield height 1/32” (.03125”) or .79375 mm. DO NOT
ATTEMPT TO ADJUST THE DOCUMENT STOP OUTSIDE THE PRESCRIBED LIMITS OR
DAMAGE TO THE PRINTER COULD RESULT. The validation form must be at least 1 inch taller
than the selected printfield.
Printfield Height
1" Min.
CCW Rev
Inches
Mm
Validation
Printfield
Print
Field
0
1
2.16
2.13
2.10
2.07
2.04
2.00
1.97
1.94
1.91
1.88
1.85
1.82
1.79
1.75
1.72
1.69
1.66
1.63
1.60
1.57
1.54
1.50
1.47
1.44
54.9
54.1
53.3
52.5
51.7
50.9
50.1
49.3
48.5
47.7
46.9
46.1
45.3
44.5
43.8
43.0
42.2
41.4
40.6
39.8
39.
2
2.78"
3
3.6"
4
5
6
Clockwise rotating lowers the
document stop and increases the
print field.
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
CW
Counter clockwise rotation raises
the document stop and decreases
the print field.
38.2
37.4
36.6
CCW
Verification of the desired document stop setting can be made by printing a Self Test on
validation media and measuring the printfield. A Self Test is initialized by turning the printer
power off, inserting a form, and turning the power back on. The validation rollers can be
opened manually by raising the printer cover and pressing downward on the yellow sector gear
if the printer will not accept a form. The printfield dimension is measured from the top of the
first line of print to the bottom of the form.
Pertech® 2006
9
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Low Paper Sensor Adjustment
The Low Paper Sensor is located on the inner-frame to the right side of the paper roll.
This sensor is a reflective optical device that can be adjusted to accommodate various roll core
diameters and quantities of paper present when low paper indication occurs. The sensor mounts
on a friction bracket and can be adjusted up or down. Lowering the bracket will cause the low
paper indication to occur earlier and raising the bracket will cause the low paper indication to
occur later.
Caution! The Low Paper Sensor will be disabled if the bracket is raised enough to “see” the
paper roll core.
Pertech® 2006
10
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Maintaining The Printer
There is no customer maintenance required for the A470 printer, however, you may
occasionally clean lint and paper dust out of the mechanism using low pressure canned air. It is
recommended that this is done on a regular basis, such as after every ribbon change. Clean the
cabinet as needed to remove finger marks and dust. Use any household cleaner designed for
plastics, but test it first on a small, unseen area. The cabinet finish and materials are durable and
resistant to the following:
Cleaning Solutions
Lubricants
Fuels
Cooking Oils
Ultraviolet Lights
Caution: Do not spray or try to clean the printhead or the inside of the printer with any kind of
cleaner. This may damage the printhead or the electronics.
Printers gather paper dust and other debris through normal use. Continued accumulation will
eventually prevent operation of the printer. A preventive maintenance program can help reduce
unnecessary failures and downtime. Pertech can offer a regular service program to meet your
needs. For more information call 800-800-6614.
Pertech® 2006
11
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Chapter 3: Print Tests and Setup Mode
Two reports are available:
Self Test / Configuration Report : Includes read and write tests of internal RAM; and a printed
report listing the serial number, firmware, font, serial parameters, hardware settings, memory
information, tallies, and the printer compatibility mode.
Extended Self Test: Checks printhead pin firing, vertical line adjustment, fonts,
validation clamp, pitches and character sets.
Self Tests & Configuration Report
The A470 produces a printout listing the current configuration settings. A sample printout is
included below. Receipt and Receipt/Journal printers will print a Self Test / Configuration Report if
the Paper Advance Button on the top cover is pressed and held while the printer power is turned
ON.
Validation printers will perform a Self Test / Configuration Report if a form is detected
when the power is turned on.
PERTECH RESOURCES INC. 47XX
To print the Configuration Report, complete
the following steps:
REVISION X.XX MK XXXX
INT9A FONT
7K RAM BUFFER
USA CHARACTER SET
1. If necessary turn the printer off.
8
BIT
DATA RATE ( BAUD )
RTS BUSY POLARITY = -12V (MARK)
AUTO LF WITH CR OFF
CHARACTERS LINE 40
-
SERIAL INTERFACE
=
9600
2. Press and hold the Paper Feed Button and
then press the Power Button to the ON position.
Release the Paper Feed Button when the printer
begins printing.
=
/
=
JOURNAL LPI = 6
DEFAULT CLAMP
/
VALIDATE LPI = 6
CLOSED
=
RIGHT MARGIN CLOCKS
=
207
DIP SWITCH “A” SETTING
DIP SWITCH “B” SETTING
=
OOCOCCOO
OCOOOOOO
=
1
2
3
4
5
6
7
8
9
Extended Self Test
If you want to run the Extended Self Test , continue to hold the Paper Feed Button
while the printer prints the Configuration Report. After the Configuration Report is done
printing the printer will begin printing the Extended Self Test. The Extended Self Test
performs a printhead pin firing test, character drop test, checks the vertical line adjust
ments, fonts, validation clamp, pitches and character sets.
Pertech® 2006
12
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Configuring the Printer
To change the configuration settings two banks of dip switches are located on the bot-
tom of the printer. On the Self Test & Configuration Report printout you can see the dip
switch configuration for both banks. Below is a table that defines what each dip switch
controls. Cycle power for dip switch changes to take effect.
= C = CLOSED
ON
OFF = O = OPEN
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Dip Switch “B”
Dip Switch “A”
Pitch / Chars. Per Line
Interface
Switch
12.0/33
13.1/36
14.4/40
16.0/44
18.0/50
20.6/57
24.0/66
Not Used
B-1
O
O
O
O
C
C
C
C
B-2
O
O
C
B-3
O
C
O
C
O
C
O
C
Switch
A-1
O
O
O
O
C
C
C
C
A-2
O
O
C
A-3
O
C
O
C
O
C
O
C
19.2k Baud
9600 Baud
4800 Baud
2400 Baud
1200 Baud
600 Baud
300 Baud
Parallel
C
C
O
O
C
O
O
C
C
C
Character Set
Switch
Usa
Journal Line Feed
B-4
O
O
O
O
C
C
C
C
B-5
O
O
C
B-6
O
C
O
C
O
C
O
C
Switch
5.3 Lpi
6.0 Lpi
6.9 Lpi
8.0
A-4
O
O
C
C
A-5
O
C
O
C
Uk
German
French
Italian
Spanish
Hebrew
Not Used
C
O
O
C
Auto Line Feed
Switch
A-6
O
C
C
On
Off
<CR>is<LF>
<CR>is<CR>
Validtion Clamp
Switch
Closed
Open
B-7
O
C
Serial Handshake (RS-232 I/F Selected)
Switch
RTS
A-7
O
A7
XON / XOFF
C
Serial Data Format
Pin 13 Select (Parallel I/F Selected)
Switch
8 Bits
7 Bits
B-8
O
C
Switch
Form In
Select Line
A-7
O
C
RTS Polarity (RS-232 I/F Selected)
Switch
-12v (Mark)
+12v (Space)
A-8
O
C
A8
Fault On Low Paper (Parallel I/F Selected)
Switch
Yes
A-8
O
No
C
Pertech® 2006
13
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Chapter 4: Communication
The A470 comes with two communication interfaces, RS-232 Serial or 1284 Parallel. Addi-
tionally, the printer is configured with dual cash drawer ports and a barrel type power coupling.
The RS-232 interface connector is a RJ45 Female connector and requires a special cable for
standard PC to printer connections. The 1284 compliant Parallel interface uses a standard
DB25 Male connector. Two RJ-11 ports provide a unique cash drawer Interface, capable of
running two cash drawers. All connectors are located on the back of the printer in the order
listed below.
Barrell Power
Connector
RJ-11 Cash Drawer
Connectors
RJ45 Serial
Connector
DB25 Parallel
Connector
8
1
Warning: use of incompatible cables will damage the printer and will void the warranty.
When purchasing a cash drawer for this product please make sure the vendor is aware
of the product specifications. This Cash Drawer Pinout is unique to Pertech Resources
A470 / DH Technology 4700 series printers.
Pertech® 2006
14
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
RS232 Serial Interface
The A470 printer serial interface has a RJ45 Female connector. The Baud Rate ,Parity and
Flow Control are selectable through Dip Switches located on the case bottom. The settings for
the port on the PC must be configured the same as the printer or communication will fail.
RS232 Serial
8
1
Serial Interface Pinout
Printer
RJ-45
Interface Cable
Host
DB-9
RJ-45 Male To Host
DB-25 DB-25
8
1
Signal Name And Direction
DCE
DTE
Female
1
2
3
4
5
6
7
8
Low Paper (TTL) *
Request To Send
Chassis Ground
Data To Host
Data To Printer
Signal Ground
N/C
8
N/C
2
3
5
N/C
4
1
2
3
7
N/C
20
N/C
5
1
3
2
7
N/C
6
Ú
Ú
ÙÚ
Ú
Ù
ÙÚ
Ú
Ú
Printer View
Form In (TTL “1” ) *
Data Term Ready
N/C
6
*Note: The control board can be modified to a “no contact” (N/C) for this printer output
Most Personal Computers using an RS-232 interface can be connected to the printer using one of the
following adapters and cables. These can be purchased by calling 1-800-800-6614.
Pre-wired adapters have a DB female connector and accept an RJ-45 cable listed below. The DB-9
connects with AT type serial ports and the DB-25 adapters provide connection with standard DCE
and DTE interfaces. Nonstandard interface requirements can be accommodated with adapter kits
that are configured by the user. These also feature an RJ-45 connector to accept one of the cables
listed below.
Standard
Non-Standard Un-Pinned
Adapter
Part Number
106356-005
106356-006
106356-007
Adapter
Part Number
DB-9 Female
DB-25F DCE
DB-25F DTE
DB-9 Female
DB-25 Female
DB-25 Male
100366-002
100366-001
100366-003
Adapter
DBXF -RJ45F RJ45M - RJ45M
Cable
The RJ-45 cable is available in several lengths and
connects any adapter listed above to the printer.
Cable length
Feet
4
10
Meters
1.22
3.05
Part Number
106155-002A
106155-003A
Pertech® 2006
15
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Flow Control
The RS-232 interface uses either XON/XOFF(Software) or RTS/CTS (Hardware) protocol. This
is set via dipswitch A 7. For the selected serial interface Flow Control of XON/XOFF, a particular
character is sent back and forth between the host computer and the printer to regulate the
communication. For RTS/CTS, changes in the RTS/CTS signal coordinate the information flow.
Parallel Interface
The Parallel interface is compatible with IEEE 1284 Parallel Interface Standards. Using the
Parallel interface with the printer requires that you set Dip Switches A1, A2, A3 to the Closed
position.
8
1
Parallel DB25 Male
�� �� �� �� �� �� �� �� �� �� �� ��
�� �� �� ��
�
�
�
�
�
�
�
�
�
Parallel Interface Pin Out
PIN
1
2
SIGNAL NAME
STROBE -
DATA 0 (LSB)
DATA 1
3
4
5
DATA 2
DATA 3
6
7
DATA 4
DATA 5
8
DATA 6
9
DATA 7 (MSB)
ACKNOWLEDGE -
BUSY
LOW PAPER
FORM IN -
N/C
FAULT -
INPUT PRIME -
N/C
10
11
12
13
14
15
16
17
18 - 25
SIGNAL GROUND
Pertech® 2006
16
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Cash Drawer
Each cash drawer driver will source 24 volts for 75 ms to the “solenoid +” pin of the appropri-
ate RJ-11 jack when the proper cash drawer command is executed. The cash drawer com-
mand must be preceded by a line terminator. The command for the cash drawer may vary for
the Compatibility Mode selected.
Pin # Cash
Drawer A
N /C
Cash
Drawer B
1
2
3
4
5
6
Solenoid +
N /C
Solenoid +
Solenoid -
Switch
Solenoid -
Switch
Switch
N / C
Switch
N /C
A470 Command Language Cash Drawer Commands
Synopsis
ASCII
Hex
Decimal
Cash Drawer “A”
Cash Drawer “B”
ESC BEL
ESC BS
1B 07
1B 08
27 7
27 8
Warning: This Printer is designed for use only with Pertech Resources A470 / DH Tech-
nology 4700 compatible cash drawers. Damage can result if the A470 is connected to a
cash drawer that is incompatible. The cash drawer solenoid resistance must be at least
25 ohms or damage to the printer could result.
Power Supply
The A470 printer uses a NTRL Certified external switching power source with a Limited Power
Source (LPS) output for use in North America, input 100-240 Vac, 50/60 Hz, 1.5 A, with a
maximum power consumption of 60 watts, output is rated at 24 Vdc,2.5A.
The power cable connector is a Mini-Din Barrel Connector and is located at the back or the
printer.
Use of this product with a power supply other than the Pertech power supply will require you
to test this power supply and Pertech printer for FCC and CE mark Certifications. ( See FCC
Radio Frequency Interference Statement on page iii of this manual).
Pertech® 2006
17
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Chapter 5: Trouble Shooting Printer Problems
Trouble Shooting General Issues
Following are symptoms your printer may exhibit and simple
solutions the printer operator could implement.
• Printer failed to print after the roll paper was replaced.
The top cover must be closed for the printer to print.
• The power switch is turned ON but the printer is dead. The Green Power LED is Off.
Make sure the outlet has power and the power cord is plugged into the
back of the printer.
• The printer will print a Configuration Report but will not respond to the system commands.
Check to see that the interface cable is connected to the back
of the terminal/ PC, and to the back of the printer.
• Printer prints too light to read easily.
Replace the ribbon cartridge and check the Air Gap adjustment. See Chapter 2 Operating the Printer \
Adjustable Features \ Air Gap Adjustment.
Call 1-800-800-6614 to order new Ribbon Cartridge’s’.
• Flashing Red Power LED indicator.
Lid open or paper is low/out.
• System reports low paper even though the roll is nearly new
See Chapter 2 Operating the Printer \ Adjustable Features \ Low Paper Adjustment.
• Colored stripe on the receipt.
Paper Low, adjust the paper low sensor, replace
the paper. See Chapter 2 Operating the Printer \
Adjustable Features \ Low Paper Adjustment..
Low Paper Sensor Adjustment
Pertech® 2006
18
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
• Receipt does not come all the way out.
Printer is jammed.
To remove paper that has jammed, it is
advisable to:
1) Tear off any paper that fed out of
the top of the mechanism
2) Press downward on the metal
release bracket
3) While pulling the remaining
paper out of the mechanism
backwards
• Status light is Red (not Green) and printer will not respond.
Remove the ribbon cartridge and paper roll. Using Low Pressure Canned Air spray out the
areas around the three sensors. (See Illustration below).
• Printer prints when the Power is turned On even though the form is not inserted.
Spray air in the validation slot and make sure no paper pieces are blocking the sensor.
Form In Sensor
There are three sensors in the
area directly under where the
Ribbon Cartridge is installed.
Check these to make sure that
they are free from dust and
debris. Reinstall the Ribbon
Cartridge and Paper. Close the
Lid and Print a Configuration
Report. If the Status Light
remains red see “Fault” later in
this chapter.
Motor Sensor
Margin Sensor
Pertech® 2006
19
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Trouble Shooting Other Issues
Fault Mode
The printer will enter a Fault Mode and will not operate when certain failure conditions are en-
countered. Confirmation of this condition can be accomplished by the host on the DTR (pin 8)
or status with an RS-232 interface, or on the printer fault line (pin 15) for the parallel interface.
A Printer in Fault Mode will not feed paper when the paper advance button on the top
cover is depressed nor will it execute commands other the Reset <ESC><NUL> or Status
<ESC><ENQ>. A parallel printer may indicate a fault when roll paper is low or out but is not in
Fault Mode. Make sure the roll paper is present when conducting this test if DIP switches A1,A2,
& A3 are closed ( parallel Interface selected) and switch A8 is Open (Fault On Low Paper).
The color of the LEFT LED on the front panel of the
printer will change from Green to Red if a fault condition
STATUS
POWER
SLIP
is encountered. Depressing the paper feed button on
the printer cover will cause the printer to enter diagnos-
tic mode. This will cause the LED to flash a 3 bit code
to define the specific reason the printer entered Fault
Mode. The error code is followed by a delay before be-
ing repeated. The diagnostic code will toggle the DTR
line and flash the Red LED if the RS-232 interface is se-
lected. It will toggle the Fault- line and flash the green
LED if the parallel interface is selected.
LOW
PAPER
STATUS
SLIP
Error code
Diagnosed failure
● ● ▬
● ▬ ●
● ▬ ▬
▬ ● ●
▬ ▬ ▬
Short
Short
Short
Long
Long
Short
Long
Long
Short
Long
Long
Short
Long
Short
Long
No motor sensor signal
Ram test failure
Firmware Error
No margin sensor signal
Head drive motor stalled
The printer will remain in FAULT Mode until the power is cycled or the printer is reset with the
<ESC> <NUL> command.
Pertech® 2006
20
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Getting Service and Technical Support
Service
You can rely on Pertech for fast turnaround, flexibility, and a highly trained and dedicated staff to
return your equipment back in first class working order. As part of Pertech, we are very familiar
with all Pertech printers. This affiliation gives us the technical and production capabilities, as
well as the financial resources and materials access, to provide product quality unequaled in
the industry
Maintenance Agreement
To keep your Pertech Product in top working order, we recommend the Pertech Maintenance
Agreement program. This service provides cleaning and upgrading for most of the printer
products we manufacture and service. Once per year, or whenever necessary, we give your
units the once over for routine maintenance, cleaning and applicable upgrades. The units are
disassembled, print heads cleaned, firmware upgraded, necessary parts replaced, and then
returned to you for another year of flawless use. Contact your Pertech Representative for
details on this and other available service and extended warranty programs.
Technical Support
Pertech provides Technical Support for this product by calling 307-856-4821 between the
hours of 8AM to 5PM Monday through Friday MST, or by submitting a Support Inquiry at the
The Model Number, Revision, Date, and Serial Number can be located on the Label attached
on the inside of the printer behind the paper roll. Please have this information available when
you contact Pertech.
MODEL 477100001E
REV
X.XX
XXXX
DATE
SERIAL XX XX XXXX
Pertech® 2006
21
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Appendix A:Pitch / Characters Per Line
The printer has 14 PITCH / FONT combinations. These are developed from 4 basic character
fonts (2 normal and 2 double wide) and a variable intercharacter space.
Chars Chars Line
/ Inch / Line Length <ESC><P>
Method
Dot Columns Dots
Ch+Sp=To
/ Line
384
396
400
396
400
392
396
396
396
400
396
400
399
396
6.0
16
18
20
22
25
28
33
33
36
40
44
50
57
66
2.67
2.75
2.78
2.75
2.78
2.72
2.75
2.75
2.75
2.78
2.75
2.78
2.77
2.75
<NUL><SO> 15+09=24
<SOH><SO> 15+07=22
<STX><SO> 15+05=20
<ETX><SO> 15+03=18
6.6
7.2
8.0
9.0
<EOT><S0>
11+05=16
10.3
12.0
12.0
13.1
14.4
16.0
18.0
20.6
24.0
<ENQ><SO> 11+03=14
<ACK><SO> 11+01=12
<NUL><SI>
<SOH><SI>
<STX><SI>
<ETX><SI>
<EOT><SI>
<ENQ><SI>
<ACK><SI>
07+05=12
07+04=11
07+03=10
07+02=09
05+03=08
05+02=07
05+02=06
CHARS / INCH characters per inch or pitch
CHARS / LINE maximum number of printed characters per line
LINE LENGTH in inches - a product of .00694 inches and DOTS / LINE
METHOD ESC P control code sequence - 1st column is the n value for the <ESC> <P>
command and the 2nd column selects double wide ON or OFF
DOT COLUMNS dot columns - per printable character (Ch), per intercharacter space (Sp)
and total (To)
Pertech® 2006
22
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
DOTS / LINE dots per line - number of dot columns used within the 400 dot printfield - a product of
dot columns (To) and CHARS / LINE
The normal fonts are 5 or 7 dot columns wide (Ch) and the Double Wide fonts are 11 or 15 dot
columns wide (2x + 1). No single dot can fire on adjacent columns, i.e. a font which is 7 dot columns
wide will not activate any single dot more than 4 times (positions 1, 3, 5 & 7).
The printfield is 2.78” wide and has 400 dot columns, each .00694” apart horizontally. Some pitch
selections do not utilize the full printfield width and terminate after the last character which can be
completely printed. All lines are left justified.
This printer employs a 9 wire impact print head, however, most characters are printed with the top
7 wires. The bottom 2 wires are used for printing the descenders on the g, j, p, q & y and when text
is underlined.
5 WIDE
7 WIDE
11 WIDE
15 WIDE
1
2
3
4
5
6
7
8
9
•
1
2
3
4
5
6
7
8
9
•
1
2
3
4
5
6
7
8
9
•
•
1
2
3
4
5
6
7
8
9
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
NORMAL WIDE
DOUBLE WIDE
Pertech® 2006
23
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Appendix B: Specifications
Some features listed in this specification do not apply to all products in the
Pertech A470 series. Refer to Chapter 1: Features and Options of this manual
to determine which features apply to a particular model.
Operating
Print Speed................................................... 4 Lines Per Second
Paper Feed Speed ....................................... 3.47 Inches Per Second
Validation ...................................................... Up To 17 Lines
Printed Line Width ........................................ 2.78” (70.6 Mm)
Pitch/font Combinations................................ 14
Pitch Range.................................................. 6 To 24
Characters Per Line...................................... 16 To 66
Character Sets.............................................. 6
Characters Per Set....................................... 224
Graphics ....................................................... 9 Wire
Line Pitch...................................................... 5.3, 6.0, 6.9 & 8.0 LPI
Environment
Storage Temperature .................................... -40°C To +65°C
...................................................................... -40°F To +150°F
Humidity (Non-condensing) .......................... 0% To 100%
Operating Temperature................................. 0°C To +50°C
...................................................................... +32°F To +122°F
Humidity (Non-condensing) .......................... 0% To 95%
Media
Roll Paper Width........................................... 3.25 +/-.03 Inches
Roll Paper Plies............................................ 1, 2 or 3
Roll Diameter ............................................... 3.5” Maximum
Roll Paper Thickness Per Ply ....................... .003”-.005”
Roll Paper Thickness Total ........................... .003”-.012”
Maximum Form Thickness............................ .020”
Maximum Total Media Thickness.................. .020”
Pertech® 2006
24
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Electrical
Interfaces...................................................... RS-232 And Parallel
Baud Rates................................................... 300 To 19200
Buffer ............................................................ 7 K
RS-232 Connector........................................ RJ45 Female
Parallel Connector........................................ DB25 Male
Cash Drawer Drivers .................................... 2 With Sense
Cash Drawer Connectors ............................. 6 Post. RJ-11 Female.
External Supply Input ................................... 90 To 264 Vac
Supply Input Frequency................................ 50 To 60 Hz
Power
Maximum................................................ 60 Watts
Standby ................................................. 2.5 Watts
Hardware
Print Head..................................................... 9 Wire Impact
Wire Diameter............................................... .012”
Center To Center Dimension......................... .0139”
Width ............................................................ 6.34” (161 Mm)
Height............................................................ 5.57” (141 Mm)
Length (471X) ............................................... 11.54” (293 Mm)
Length (477X) ............................................... 8.3” (211 Mm)
Printer Weight (471X) ................................... 6.5 Lbs (2.95 Kg)
Printer Weight (477X) ................................... 5.7 Lbs (2.59 Kg)
Power Supply Weight.................................... 1.1 Lbs (.50 Kg)
Pertech® 2006
25
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Pertech® 2006
26
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Index
A
I
Adjustable Features 8, 18
Advanced Control Language vii
Air Gap Adjustment 8, 18
Incorrect rom checksum 20
Independent feed 2
Information to the User iii
Interfaces 2, 25
B
Interface Cable 16, iv
Baud 15, 25
J
C
Jam. 19
Canned Air 11
Cash Drawer 14, 17
Caution 10, 11
L
Low Paper Sensor Adjustment 10, 18
Lubricants 11
Character Sets 2, 24
Cleaning Solutions 11
Communication Interfaces 14
Compatibility Modes 1
Concurrent feed 2
Configuration Report 9, 12
Copyright iii
M
Maintenance 11, 21
Margin Sensor 19
Media 24
Model specific features 2
Motor Sensor 19
D
N
diagnostic code 20
Disclaimer iii
Document Stop 9
Note iii
No margin sensor signal 20
No motor sensor signal 20
E
P
Environment 24
Paper Feed Button 12
Paper Loading 5
Paper Low Sensor 2
Parity 15
F
Fault Mode 20
FEED TYPE 2
Flash Memory. 2
Flow Control 15, 16
Form In Sensor 2, 19
Power Cord iv
Power Supply 17, 25, iv
Printer Controls 4
printfield dimension 9
Print Speed 24
H
publications vii
Hardware 16, 25
Head drive motor stalled 20
Pertech® 2006
27
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
R
T
Ram test failure 20
Resident character sets 2
Revision 21
Ribbon Cartridge 7, 19
Ribbon Interlock Tab 7
Roll Diameter 24
Technical Support 21
Trademarks iii
Trouble Shooting 18, 20
U
USB 1, 14, 16, 25
Roll Paper Plies 24
Roll Paper Width 24
V
S
Validation Form 8
validation printfield height 9
Sector Gear 9
Self Test 8, 9, 12
Serial Number 21
serial number 12
Service 21
service 3, 11, 21
Slow Down mode 4
Specifications 22, 24
Standard Features 2
Status light 18, 19
W
Warning 14, iii
Warranty 29
Web site iii
Pertech® 2006
28
Download from Www.Somanuals.com. All Manuals Search And Download.
A470 Users Guide
Warranty
Warranty
Pertech Resources warrants all of its transaction printers against defects in material and
workmanship for a period of 24 months from date of shipment by Pertech Resources or the
rated maximum number of transactions for the specific product – whichever comes first. Kiosk
printers, mechanisms and distributed products carry warranties specific to their application or
product warranty.
Pertech Resources does not consider damage caused by replacement ribbons or replacement
parts supplied by parties other than Pertech Resources to be a defect in material or workmanship.
This is a limited warranty, limited exclusively to its terms, including the exclusive remedies set
forth below. In addition, this warranty is void if the product has been altered, misused, taken apart
or otherwise abused. All other warranties, expressed or implied are excluded, including but not
limited to the implied warranties of merchantability and fitness for particular purpose. Any warranty
claims must be supported by proof of purchase, represented by reference to the customers’
purchase order.
Buyer’s Remedies
Pertech Resources’ obligations and liabilities under the foregoing warranty are limited to repair or
replacement of the product without charge, provided it is shipped prepaid to Pertech Resources,
860 College View Drive, Riverton, WY 82501-2298. A charge is made for repairs after the
expiration of the warranty period. In addition, if a printer is returned and replacement ribbons or
other replacement parts not supplied by Pertech Resources have caused the printer damage, a
reasonable charge for repair will be assessed. Printers returned under warranty discovered to
be a “no fault found” will be charged the standard repair cost plus return freight. In no event shall
Pertech Resources be liable for claims based upon breach of expressed or implied warranty
or negligence or any other damages whether direct, immediate, foreseeable, consequential
or special or for any expenses incurred by reason of the use or misuse, sale or fabrications of
products which do not conform to the terms and conditions of this contract.
®
860 College View Drive
Riverton, Wyoming, 82501
307-856-4821
Pertech® 2006
29
Download from Www.Somanuals.com. All Manuals Search And Download.
|