ADDENDUM  
Addendum No.: C1648M ADDEN  
Date: April 29, 2005  
Manual Affected: FT85081/FR85081 Fiber Transmitter and Receiver  
Installation Manual – C1648M  
Manual Update: Attachment of Ferrite to Data Cable of FT85081 Transmitter  
A snap-on ferrite is supplied with the FT85081MSTR,  
FT85081SSTR, and FT85081SFCR transmitters. The ferrite  
must be attached to the data cable of the transmitters to  
comply with FCC and CE emissions requirements.  
After data connections are made to the data connector on  
the transmitter, attach the ferrite to the data cable. When  
attaching the ferrite to the cable, position the ferrite as  
close as possible to the transmitter.  
NOTE: The ferrite should fit securely around the cable.  
If the ferrite is loose and slides along the cable, loop the  
cable through the ferrite before closing the ferrite.  
If, however, the thickness of the cable prevents the ferrite  
from closing, use a tie wrap to hold the ferrite in place  
rather than looping the cable.  
Pelco World Headquarters • 3500 Pelco Way, Clovis, California 93612-5699 USA  
USA & Canada: Tel: 800/289-9100 • Fax: 800/289-9150  
International: Tel: 1-559/292-1981 • Fax: 1-559/348-1120  
®
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Package Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
Data Communication Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
Mounting the Transmitter/Receiver into a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
Mounting the Transmitter/Receiver Using the Wall Clip. . . . . . . . . . . . . . . . . . . .15  
1
Mounting the FT85081 Transmitter/FR85081 Receiver Using the Wall Clip. . . . . . . . . .15  
FT85081 Transmitter/FR85081 Receiver Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
RS-232 Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
RS-422 Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19  
RS-485 2-Wire (Half Duplex) Data Communication Wiring. . . . . . . . . . . . . . . . . . . . . . . 20  
RS-485 4-Wire (Full Duplex) Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . 21  
Manchester Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22  
Bi-Phase Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23  
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
2
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Tables  
A
B
C
Data Selection Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
Data Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17  
Troubleshooting with Front-Panel Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
Important Safety Instructions  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
4. Follow all instructions.  
5. Do not use this apparatus near water.  
6. Clean only with dry cloth.  
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s  
instructions.  
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other  
apparatus (including amplifiers) that produce heat.  
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized  
plug has two blades with one wider than the other. A grounding plug has two blades  
and a third grounding prong. The wide blade or the third prong are provided for your  
safety. If the provided plug does not fit into your outlet consult an electrician for  
replacement of the obsolete outlet.  
10. Protect the power cord from being walked on or pinched particularly at plugs,  
convenience receptacles, and the points where they exit from the apparatus.  
11. Only use attachments/accessories specified by the manufacturer.  
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or  
sold with the apparatus. When a cart is used, use caution when moving the cart/  
apparatus combination to avoid injury from tip-over.  
13. Unplug this apparatus during lightning storms or when unused for long periods of time.  
14. Refer all servicing to qualified service personnel. Servicing is required when the  
apparatus has been damaged in any way, such as power-supply cord or plug is  
damaged, liquid has been spilled or objects have fallen into the apparatus, the  
apparatus has been exposed to rain or moisture, does not operate normally, or has been  
dropped.  
15. Apparatus shall not be exposed to dripping or splashing and that no objects filled with  
liquids, such as vases shall be placed on the apparatus.  
16. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to  
rain or moisture.  
17. Installation should be done only by qualified personnel and conform to all local codes.  
18. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P  
enclosure, it is designed for indoor use only and it must not be installed where exposed  
to rain and moisture.  
19. Use only installation methods and materials capable of supporting four times the  
maximum specified load.  
4
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CAUTION: These servicing instructions are for use by qualified service personnel only.  
To reduce the risk of electric shock do not perform any servicing other that contained in  
the operating instructions unless you are qualified to do so.  
The product and/or manual may bear the following marks:  
This symbol indicates that dangerous voltage  
constituting a risk of electric shock is present  
within this unit.  
CAUTION:  
RISK OF ELECTRIC SHOCK.  
This symbol indicates that there are important  
operating and maintenance instructions in the  
DO NOT OPEN.  
literature accompanying this unit.  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
Regulatory Notices  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two  
conditions: (1) this device may not cause harmful interference, and (2) this device must accept  
any interference received, including interference that may cause undesired operation.  
RADIO AND TELEVISION INTERFERENCE  
This equipment has been tested and found to comply with the limits of a Class A digital device,  
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection  
against harmful interference when the equipment is operated in a commercial environment.  
This equipment generates, uses, and can radiate radio frequency energy and, if not installed  
and used in accordance with the instruction manual, may cause harmful interference to radio  
communications. Operation of this equipment in a residential area is likely to cause harmful  
interference in which case the user will be required to correct the interference at his own  
expense.  
Changes and Modifications not expressly approved by the manufacturer or registrant of this  
equipment can void your authority to operate this equipment under Federal Communications  
Commission’s rules.  
This Class A digital apparatus complies with Canadian ICES-003.  
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.  
6
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Product Overview  
DESCRIPTION  
The FT85081/FR85081 fiber transmitter and receiver provide the ability to transmit eight  
unidirectional composite video channels and one bidirectional data channel over one optical  
fiber (refer to Figure 1).  
EIGHT  
VIDEO  
EIGHT  
VIDEO  
INPUTS  
OUTPUTS  
FT85081  
FR85081  
TRANSMITTER  
RECEIVER  
ONE  
FIBER  
DATA  
DATA  
Figure 1. Eight-Channel Video FT85081 Transmitter and FR85081 Receiver  
with Bidirectional Data Channel  
Features of the FT85081/FR85081 fiber optic transmission system include the following:  
8-bit digitally encoded video for high-quality multi-channel video transmission over a  
single fiber  
Bidirectional data channel that supports RS-232, RS-422, RS-485 (2-wire/4-wire),  
Manchester, and Bi-Phase communication  
Wavelength division multiplexing (WDM), allowing video and data channels to be  
transmitted in the same fiber using different wavelengths  
Multimode fiber support for distances up to 1 km (0.6 mi)  
Single-mode fiber support for distances up to 30 km (18.6 mi)  
Exceeds all requirements for the RS-250C Medium-Haul Transmission specification  
Compatible with NTSC, PAL, and SECAM video standards  
No performance adjustments required  
12 VDC or 24 VAC power supply  
Standalone and rack-mountable modular design  
LED indicators for monitoring of signal status, data activity, and operating power  
NOTE: The FT85081 transmitter/FR85081 receiver is a Class 1 laser product that  
complies with FDA radiation performance standard 21CFR Subchapter J and with  
IEC 60825-1 Edition 1.2, 2001-08.  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
     
MODELS  
The FT85081/FR85081 fiber transmitter and receiver consist of the following series of models:  
Multimode Models:  
FT85081MSTR  
FR85081MSTR  
Eight-channel fiber optic video transmitter/single-channel data transceiver;  
multimode, ST connector  
Eight-channel fiber optic video receiver/single-channel data transceiver;  
multimode, ST connector  
Single-Mode Models:  
FT85081SSTR  
FR85081SSTR  
FT85081SFCR  
FR85081SFCR  
Eight-channel fiber optic video transmitter/single-channel data transceiver;  
single-mode, ST connector  
Eight-channel fiber optic video receiver/single-channel data transceiver;  
single-mode, ST connector  
Eight-channel fiber optic video transmitter/single-channel data transceiver;  
single-mode, FC connector  
Eight-channel fiber optic video receiver/single-channel data transceiver;  
single-mode, FC connector  
OPTIONAL ACCESSORIES  
The following optional accessories are available:  
RK5000-3U  
19-inch rack mount chassis for 14 slots (no power), 3 RUs  
RK5000PS-3U  
EPS5000-120  
RK5001B-3U  
RK5002B-3U  
RK5003-1UEXP  
19-inch rack mount chassis for 12 slots with power, 3 RUs  
External/redundant power supply, 1 RU, 120 W x 2  
Blank filler panel, single width  
Blank filler panel, double width  
Adapter kit that allows a 3 RU triple-width fiber optic module to be used in  
RK5000PS-5U rack mount chassis  
8
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
FRONT PANEL  
The front panel of the FT85081 transmitter and the FR85081 receiver provides LED indicators  
that allow you to monitor data activity, signal status, and operating power. The following  
sections provide a view of the front panel of the FT85081 transmitter and the FR85081 receiver.  
FRONT PANEL - FT85081 TRANSMITTER  
Figure 2 illustrates the front panel of the FT85081 transmitter.  
8
7
6
5
4
3
2
1
Tx  
Rx  
Figure 2. Front Panel of FT85081 Transmitter  
DATA TX LED  
DATA RX LED  
CARRIER DETECT LED  
POWER LED (Pelco badge)  
VIDEO PRESENT LEDs (1-8)  
For detailed information about the front-panel indicators, refer to the Troubleshooting section.  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
     
FRONT PANEL - FR85081 RECEIVER  
Figure 3 illustrates the front panel of the FR85081 receiver.  
8
4
3
2
1
7
Tx  
6
Rx  
5
Figure 3. Front Panel of FR85081 Receiver  
DATA TX LED  
DATA RX LED  
POWER LED (Pelco badge)  
VIDEO PRESENT LEDs (1-8)  
CARRIER DETECT LED  
For detailed information about the front-panel indicators, refer to the Troubleshooting section.  
10  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
REAR PANEL  
Connections to the FT85081 transmitter and the FR85081 receiver are made to the rear panel  
of the module. The following sections provide a view of the rear panel of the FT85081  
transmitter and the FR85081 receiver.  
REAR PANEL - FT85081 TRANSMITTER  
Figure 4 illustrates the rear panel of the FT85081 transmitter.  
1
2
3
4
5
6
7
8
8
7
6
5
GND  
3
9
Figure 4. Rear Panel of FT85081 Transmitter  
RACK POWER/ALARM CONNECTOR, 4-pin connector for power/alarm connection of  
rack-mounted module  
STANDALONE POWER CONNECTOR, 2-pin connector for power connection of standalone  
module; removable mating connector with screw terminals (not shown)  
VIDEO IN CONNECTORS (1-8), 75-ohm BNC analog video input  
FIBER OPTIC CONNECTOR, ST or FC (dependent on FT85081 model)  
DATA CONNECTOR, 9-pin connector; removable mating connector with screw terminals  
(not shown)  
DATA SELECTION SWITCH, 10-position rotary switch (positions 0-9)  
For additional information about rear-panel connections and about the Data Selection switch,  
refer to the Installation section.  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
     
REAR PANEL - FR85081 RECEIVER  
Figure 5 illustrates the rear panel of the FR85081 receiver.  
1
2
3
4
5
6
7
8
7
8
GND  
3
6
5
9
Figure 5. Rear Panel of FR85081 Receiver  
RACK POWER/ALARM CONNECTOR, 4-pin connector for power/alarm connection of  
rack-mounted module  
STANDALONE POWER CONNECTOR, 2-pin connector for power connection of standalone  
VIDEO OUT CONNECTORS (1-8), 75-ohm BNC analog video output  
FIBER OPTIC CONNECTOR, ST or FC (dependent on FR85081 model)  
DATA CONNECTOR, 9-pin connector; removable mating connector with screw terminals  
DATA SELECTION SWITCH, 10-position rotary switch (positions 0-9)  
For additional information about rear-panel connections and about the Data Selection switch,  
refer to the Installation section.  
12  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation  
PACKAGE CONTENTS  
The following items are supplied:  
With the FT85081 transmitter:  
1
1
1
Regulated switching power supply with four plug adapters (North American,  
Australian, U.K., and European configurations); 100-240 VAC input, 12 VDC output  
Wall clip with two 4-40 x .250-inch Phillips pan head screws with lock washers  
(for attachment of single module to wall)  
FT85081/FR85081 Fiber Transmitter and Receiver Installation manual (this manual)  
With the FR85081 receiver:  
1
1
1
Regulated switching power supply with four plug adapters (North American,  
Australian, U.K., and European configurations); 100-240 VAC input, 12 VDC output  
Wall clip with two 4-40 x .250-inch Phillips pan head screws with lock washers  
(for attachment of single module to wall)  
FT85081/FR85081 Fiber Transmitter and Receiver Installation manual (this manual)  
DATA COMMUNICATION SETUP  
NOTE: As a matter of convenience, it is recommended that you set the desired data  
communication before mounting the FT85081 transmitter/FR85081 receiver into a rack  
or onto a wall.  
The Data Selection switch, which is located on the rear panel of the FT85081 transmitter/  
FR85081 receiver, is a 10-position rotary switch that allows you to set the data communication  
required for the transfer of data (refer to Figure 6).  
1
2
3
4
5
6
7
8
8
7
6
5
3
GND  
1
0
DATA  
SELECTION  
SWITCH  
3
9
Figure 6. Data Selection Switch  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
       
With the FT85081 transmitter/FR85081 receiver powered off, turn the Data Selection switch  
using a screwdriver until the number representing the required data communication is selected.  
Refer to Table A for Data Selection switch settings.  
Table A. Data Selection Switch Settings  
Data Selection  
RS-232  
Switch Setting  
0 (default setting)  
RS-422  
1
RS-485 2-Wire  
RS-485 4-Wire  
Manchester/Bi-Phase  
Not used  
2
3
4
5-9  
Note the following:  
The FT85081 transmitter/FR85081 receiver allows data translation between RS-232 and  
RS-422 signal levels. Consequently, the Data Selection switch can be set to 0 (RS-232)  
on the transmitter and to 1 (RS-422) on the receiver. Conversely, the Data Selection  
switch can be set to 1 (RS-422) on the transmitter and to 0 (RS-232) on the receiver.  
If you wish to change the data communication setting after the FT85081 transmitter/  
FR85081 receiver has been powered on, power off the transmitter/receiver, change the  
data communication setting, and then power on the transmitter/receiver again.  
MOUNTING  
The FT85081 transmitter/FR85081 receiver can be mounted into a rack or can be used as a  
standalone module. As a standalone module, the unit can be placed on a desktop or can be  
mounted to a wall.  
NOTE: As a matter of convenience, it is recommended that you set the desired data  
communication before mounting the FT85081 transmitter/FR85081 receiver. To set the  
desired data communication, refer to the Data Communication Setup section.  
MOUNTING THE TRANSMITTER/RECEIVER INTO A RACK  
The FT85081 transmitter/FR85081 receiver can be installed into the RK5000 Series rack mount  
chassis, which can be mounted into an industry-standard 19-inch (48.26 cm) equipment rack.  
The RK5000 Series rack mount chassis includes the following models:  
RK5000PS-3U and RK5000-3U: Designed to accommodate fiber optic modules as  
follows:  
The RK5000PS-3U rack mount chassis provides 12 single-width module slots and  
a power supply.  
The RK5000-3U rack mount chassis provides 14 single-width module slots (a  
power supply is not included). Power to the modules can be supplied using the  
optional external power supply (EPS5000-120).  
For additional information, refer to the RK5000PS-3U/RK5000-3U Fiber Rack Mount  
Chassis Installation manual.  
14  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
RK5000PS-5U: Designed to accommodate Enduramodules but can also  
accommodate fiber optic modules with the use of the appropriate adapter kit. The  
RK5003-1UEXP adapter kit is required for installation of the FT85081 transmitter/  
FR85081 receiver into the RK5000PS-5U chassis.  
For information about the RK5000PS-5U chassis, refer to the RK5000PS-5U Rack Mount  
Chassis Installation manual.  
that occupies three slots in the RK5000PS-3U, RK5000-3U, and RK5000PS-5U chassis.  
MOUNTING THE TRANSMITTER/RECEIVER USING THE WALL CLIP  
NOTE: Before mounting the FT85081 transmitter/FR85081 receiver to a wall, ensure  
that there is adequate space at both ends for viewing the front-panel LEDs and for  
making the various rear-panel cable connections.  
To attach the FT85081 transmitter/FR85081 receiver to a wall using the supplied wall clip, refer  
to Figure 7 and do the following:  
1. Using the two vertical or horizontal wall-mounting holes, attach the wall clip to a wall  
using two screws (not provided).  
2. Slide the module into the clip until the two holes on the bottom of the module align with  
the two holes on the lower flange of the clip.  
3. Attach the module to the clip using the two Phillips pan head screws provided for the clip.  
UPPER  
FLANGE  
VERTICAL  
MOUNTING HOLE (2)  
HORIZONTAL  
MOUNTING HOLE (2)  
TRANSMITTER/  
RECEIVER  
LOWER  
SCREW, PHILLIPS  
PAN HEAD WITH  
LOCK WASHER (2)  
FLANGE  
WALL CLIP  
Figure 7. Mounting the FT85081 Transmitter/FR85081 Receiver Using the Wall Clip  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
   
CONNECTIONS  
Connections to the FT85081 transmitter and the FR85081 receiver are made on the rear panel  
of the modules and consist of the following:  
Power connection  
NOTE: A 12 VDC or 24 VAC power supply can be used to power the transmitter/receiver  
power supply is used, the power supply must be a Listed Direct Plug-In Power Unit  
marked as Class 2 and rated as 24 VAC, 200 mA (minimum output).  
Video input connections (transmitter only)  
Video output connections (receiver only)  
Fiber connection  
Data connection  
Figure 8 provides an illustration of FT85081 transmitter/FR85081 receiver connections.  
POWER/ALARM  
CONNECTION FOR  
RACK-MOUNTED MODULE*  
FIBER OPTIC CABLE  
POWER CONNECTION  
FOR STANDALONE MODULE†  
1
2
3
4
5
6
7
8
COAXIAL  
CABLE  
8
7
6
5
GND  
2
1
DATA COMMUNICATION  
CABLE (REFER TO TABLE B  
FOR DATA CONNECTOR  
PIN ASSIGNMENTS AND  
TO FIGURES 9-14 FOR  
9
COAXIAL  
CABLE  
WIRING DIAGRAMS)  
*REFER TO THE RK5000PS-3U/RK5000-3U FIBER RACK MOUNT CHASSIS INSTALLATION  
MANUAL FOR INFORMATION.  
†THE STRIPED WIRE OF THE SUPPLIED 12 VDC POWER SUPPLY CONNECTS TO THE  
PIN 1 SCREW TERMINAL (DC+) OF THE STANDALONE POWER CONNECTOR. THE  
OTHER WIRE CONNECTS TO THE PIN 2 SCREW TERMINAL (DC-).  
Figure 8. FT85081 Transmitter/FR85081 Receiver Connections  
16  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Table B. Data Connector Pin Assignments  
Pin  
RS-485  
2-Wire  
RS-485  
4-Wire  
Number RS-232 RS-422  
Manchester  
Bi-Phase  
1
2
3
4
5
6
7
8
9
Out+  
Out-  
In+  
In-  
In+/Out+ Out+  
In-/Out-  
Out-  
In+  
In-  
In+ (W)  
In- (B)  
In+  
In-  
In  
Out  
Out+ (W)  
Out- (B)  
Shield  
Out+  
Out-  
Shield  
Ground  
—*  
—*  
—*  
*Ground may be required based on conditions of installation. Refer to the current version of  
EIA/TIA-422 and EIA/TIA-485 standards for additional information.  
NOTES:  
In, In+, and In- denote data input to the transmitter/receiver.  
Out, Out+, and Out- denote data output from the transmitter/receiver.  
W denotes white wire, and B denotes black wire.  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
 
FR85081  
RECEIVER –  
DATA CONNECTOR  
DEVICE A  
1
2
3
4
5
6
7
8
RS-232  
DATA SELECTION  
3
2
RS-232  
0
RX  
TX  
(RX) DATA IN  
(TX) DATA OUT  
9
GND  
GND  
RS-232 DATA CONNECTIONS BETWEEN DEVICE A AND FR85081 RECEIVER  
FT85081  
TRANSMITTER –  
DEVICE B  
DATA CONNECTOR  
1
2
3
4
5
6
7
8
RS-232  
DATA SELECTION  
3
2
RS-232  
0
RX  
TX  
(RX) DATA IN  
(TX) DATA OUT  
9
GND  
GND  
RS-232 DATA CONNECTIONS BETWEEN DEVICE B AND FT85081 TRANSMITTER  
Figure 9. RS-232 Data Communication Wiring  
18  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
FR85081  
RECEIVER –  
DATA CONNECTOR  
DEVICE A  
RX+  
RS-422  
1
2
3
4
5
6
7
8
(TX+) DATA OUT+  
RS-422  
DATA SELECTION  
RX-  
TX+  
TX-  
(TX-) DATA OUT-  
(RX+) DATA IN+  
(RX-) DATA IN-  
3
2
1
0
GND  
RS-422 DATA CONNECTIONS BETWEEN DEVICE A AND FR85081 RECEIVER  
FT85081  
TRANSMITTER –  
DEVICE B  
DATA CONNECTOR  
RS-422  
RX+  
RX-  
TX+  
TX-  
1
2
3
4
5
6
7
8
(TX+) DATA OUT+  
RS-422  
DATA SELECTION  
(TX-) DATA OUT-  
(RX+) DATA IN+  
(RX-) DATA IN-  
3
2
1
0
GND  
RS-422 DATA CONNECTIONS BETWEEN DEVICE B AND FT85081 TRANSMITTER  
Figure 10. RS-422 Data Communication Wiring  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
 
FR85081  
RECEIVER –  
DATA CONNECTOR  
RS-485  
2-WIRE  
DEVICE A  
RX+/TX+  
RX-/TX-  
1
2
3
4
5
6
7
8
(TX+/RX+) DATA OUT+/DATA IN+  
(TX-/RX-) DATA OUT-/DATA IN-  
RS-485 2-WIRE  
DATA SELECTION  
3
2
1
GND  
RS-485 2-WIRE DATA CONNECTIONS BETWEEN DEVICE A AND FR85081 RECEIVER  
FT85081  
TRANSMITTER –  
DATA CONNECTOR  
RS-485  
2-WIRE  
DEVICE B  
RX+/TX+  
RX-/TX-  
1
2
3
4
5
6
7
8
(TX+/RX+) DATA OUT+/DATA IN+  
(TX-/RX-) DATA OUT-/DATA IN-  
RS-485 2-WIRE  
DATA SELECTION  
3
2
1
GND  
RS-485 2-WIRE DATA CONNECTIONS BETWEEN DEVICE B AND FT85081 TRANSMITTER  
Figure 11. RS-485 2-Wire (Half Duplex) Data Communication Wiring  
20  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
FR85081  
RECEIVER –  
DATA CONNECTOR  
RS-485  
4-WIRE  
DEVICE A  
RX+  
1
2
3
4
5
6
7
8
(TX+) DATA OUT+  
RS-485 4-WIRE  
DATA SELECTION  
RX-  
TX+  
TX-  
(TX-) DATA OUT-  
(RX+) DATA IN+  
(RX-) DATA IN-  
3
2
GND  
RS-485 4-WIRE DATA CONNECTIONS BETWEEN DEVICE A AND FR85081 RECEIVER  
FT85081  
TRANSMITTER –  
DATA CONNECTOR  
RS-485  
4-WIRE  
DEVICE B  
RX+  
1
2
3
4
5
6
7
8
(TX+) DATA OUT+  
RS-485 4-WIRE  
DATA SELECTION  
RX-  
(TX-) DATA OUT-  
(RX+) DATA IN+  
(RX-) DATA IN-  
TX+  
TX-  
3
2
GND  
RS-485 4-WIRE DATA CONNECTIONS BETWEEN DEVICE B AND FT85081 TRANSMITTER  
Figure 12. RS-485 4-Wire (Full Duplex) Data Communication Wiring  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21  
 
FR85081  
RECEIVER –  
DATA CONNECTOR  
DEVICE A  
1
2
MANCHESTER  
DATA SELECTION  
MANCHESTER  
SHIELD  
W*  
B*  
3
4
5
6
7
8
(RX+) DATA IN+  
(RX-) DATA IN-  
3
2
4
GND  
MANCHESTER DATA CONNECTIONS BETWEEN DEVICE A AND FR85081 RECEIVER  
FT85081  
TRANSMITTER –  
DEVICE B  
DATA CONNECTOR  
1
2
3
4
5
6
MANCHESTER  
DATA SELECTION  
MANCHESTER  
3
2
W*  
B*  
4
7
8
(TX+) DATA OUT+  
(TX-) DATA OUT-  
SHIELD  
GND  
MANCHESTER DATA CONNECTIONS BETWEEN DEVICE B AND FT85081 TRANSMITTER  
*W DENOTES WHITE WIRE, AND B DENOTES BLACK WIRE.  
Figure 13. Manchester Data Communication Wiring  
22  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
FR85081  
RECEIVER –  
DEVICE A  
DATA CONNECTOR  
1
2
BI-PHASE  
DATA SELECTION  
BI-PHASE  
OUT+  
OUT-  
3
4
5
6
7
8
(RX+) DATA IN+  
(RX-) DATA IN-  
3
2
4
SHIELD  
GND  
BI-PHASE DATA CONNECTIONS BETWEEN DEVICE A AND FR85081 RECEIVER  
FT85081  
TRANSMITTER –  
DEVICE B  
DATA CONNECTOR  
1
2
3
4
5
6
BI-PHASE  
DATA SELECTION  
BI-PHASE  
IN+  
IN-  
3
2
4
1
7
8
(TX+) DATA OUT+  
(TX-) DATA OUT-  
SHIELD  
GND  
BI-PHASE DATA CONNECTIONS BETWEEN DEVICE B AND FT85081 TRANSMITTER  
Figure 14. Bi-Phase Data Communication Wiring  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
 
Troubleshooting  
LED indicators on the front panel of the FT85081 transmitter/FR85081 receiver (refer to Figure 2  
and Figure 3, respectively) allow you to monitor signal status, data activity, and operating  
power. Table C provides information about the front-panel indicators and associated  
troubleshooting guidelines.  
Table C. Troubleshooting with Front-Panel Indicators  
Indicator Color  
Meaning  
Possible Cause  
Corrective Action  
Power LED (Pelco badge)  
Blue Pelco logo lights. Power is being applied  
to the module.  
No action required.  
Blue Pelco logo does Power is not being  
Power connection is  
Check power  
not light.  
applied to the module. faulty.  
connection. If module is  
rack mounted, reseat  
module or power supply  
as necessary.  
Power supply has failed. Replace power supply.  
Loss of power occurs  
due to tripped circuit  
breaker(s), blown  
fuse(s), or faulty  
Check circuit breaker(s),  
fuse(s), or electrical  
service as necessary.  
electrical service.  
Video Present LED  
Incoming video signal is —  
Green  
No action required.  
present on the channel.  
Red on transmitter  
Incoming video signal is Video source is not  
Check power connection  
to the video source.  
not present on the  
channel.  
powered on.  
Video source is not  
connected to the  
transmitter.  
Check BNC connections.  
Coaxial cable is  
defective.  
Replace cable.  
(Continued on next page)  
24  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Table C. Troubleshooting with Front-Panel Indicators (Continued)  
Indicator Color  
Meaning  
Possible Cause  
Corrective Action  
Video Present LED (Continued)  
Red on receiver  
Incoming video signal is Optical signal is not  
Refer to the Carrier  
not present on the  
channel.  
being received from the Detect LED  
transmitter. Carrier  
troubleshooting section  
Detect LED is also red. below.  
Video source is not  
powered on.  
Check power connection  
to the video source.  
Video source is not  
connected to the  
transmitter.  
Check BNC connections.  
Coaxial cable connected Replace cable.  
to the transmitter is  
defective.  
Carrier Detect LED  
Green on transmitter The optical signal is  
being received from the  
receiver.  
No action required.  
No action required.  
Green on receiver  
The optical signal is  
being received from the  
transmitter.  
Red on transmitter  
The optical signal is not Receiver is not powered Check power  
being received from the on.  
receiver.  
connections. Replace  
power supply if  
necessary.  
Fiber optic cable is not Check fiber optic  
connected.  
connections.  
Fiber optic cable  
Clean, polish, or replace  
connectors are dirty or fiber optic cable  
are damaged.  
connectors as  
necessary.  
Fiber optic cable is  
defective.  
Replace cable.  
(Continued on next page)  
C1648M (4/05)  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table C. Troubleshooting with Front-Panel Indicators (Continued)  
Indicator Color  
Meaning  
Carrier Detect LED (Continued)  
A problem exists with Verify that losses in  
Possible Cause  
Corrective Action  
Red on transmitter  
(continued)  
the optical power  
budget.  
fiber optic cable do not  
exceed the optical  
power budget  
specification of the fiber  
optic link. If the losses  
do exceed the optical  
power budget, contact  
Product Support.  
Red on receiver  
The optical signal is not Transmitter is not  
being received from the powered on.  
transmitter.  
Check power  
connections. Replace  
power supply if  
necessary.  
Fiber optic cable is not Check fiber optic  
connected.  
connections.  
Fiber optic cable  
Clean, polish, or replace  
connectors are dirty or fiber optic cable  
are damaged.  
connectors as  
necessary.  
Fiber optic cable is  
defective.  
Replace cable.  
A problem exists with Verify that losses in  
the optical power  
budget.  
fiber optic cable do not  
exceed the optical  
power budget  
specification of the fiber  
optic link. If the losses  
do exceed the optical  
power budget, contact  
Product Support.  
(Continued on next page)  
26  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table C. Troubleshooting with Front-Panel Indicators (Continued)  
Indicator Color  
Meaning  
Possible Cause  
Data Tx LED  
Corrective Action  
Flashing amber  
Data is being  
No action required.  
transmitted onto the  
fiber by the data port.  
Red  
Data Selection switch is Data Selection switch is Set Data Selection  
set to an invalid setting. set to setting 5, 6, 7, 8, switch to the correct  
or 9.  
setting for the desired  
data communication  
(refer to Table A).  
Not lit  
Data is not being  
transmitted onto the  
fiber by the data port.  
Data is not present on No action required.  
the channel.  
Data connection is  
faulty.  
Check data connections.  
Data communication  
cable is defective.  
Replace cable.  
Data Rx LED  
Flashing amber  
Red  
Data is being received  
from the fiber by the  
data port.  
No action required.  
Data Selection switch is Data Selection switch is Set Data Selection  
set to an invalid setting. set to setting 5, 6, 7, 8, switch to the correct  
or 9.  
setting for the desired  
data communication  
(refer to Table A).  
Not lit  
Data is not being  
Data is not present on No action required.  
received from the fiber the channel.  
by the data port.  
Data connection is  
faulty.  
Check data connections.  
Replace cable.  
Data communication  
cable is defective.  
C1648M (4/05)  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
VIDEO  
Number of Channels  
Modulation Type  
Video Input  
8
Pulse code modulation, 8-bit resolution  
1.0 Vp-p, 75 ohms; NTSC, PAL, and SECAM  
Bandwidth  
6.5 MHz  
Gain  
Unity  
Crosstalk  
-50 dB typical at 3.58 MHz  
Differential Gain  
Differential Phase  
Tilt  
<1%  
<1.2°  
<1%  
Signal-to-Noise Ratio  
>60 dB (CCIR weighted)  
DATA  
Number of Channels  
Data Communication  
1
RS-232, RS-422, RS-485 (2-wire/4-wire), Manchester,  
Bi-Phase  
Maximum Baud Rate  
500 kbps  
GENERAL  
Operating Temperature  
Input Power Requirements  
LED Indicators  
-40° to 167°F (-40° to 75°C)  
12 VDC or 24 VAC, 600 mA  
Power  
Video Present (per channel)  
Carrier Detect  
Data Tx  
Data Rx  
Dimensions  
Unit Weight  
8.75” D x 3.48” W x 4.81” H  
22.23 x 8.84 x 12.22 cm  
3.50 lb (1.59 kg)  
MECHANICAL  
Connectors  
Video  
BNC (per channel)  
Rack Power/Alarm  
Standalone Power  
Data  
4-pin connector  
2-pin connector, screw terminal  
9-pin connector, screw terminal  
Fiber Optic  
ST for multimode fiber  
ST or FC for single-mode fiber  
28  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
OPTICAL POWER BUDGET, TRANSMISSION DISTANCE, AND LASER CLASS 1 LIMIT  
Optical  
Power  
Budget  
20 dB†  
20 dB†  
20 dB  
20 dB  
Maximum  
Transmission  
Distance  
1 km (0.6 mi)††  
1 km (0.6 mi)††  
30 km (18.6 mi)§  
30 km (18.6 mi)§  
Laser  
Class 1  
Limit*  
Fiber  
Wavelength  
1310 nm (video)  
850 nm (data)  
1310 nm (video)  
1550 nm (data)  
Multimode  
(62.5/125 µm)  
<15.6 mW  
<0.78 mW  
<15.6 mW  
<10.0 mW  
Single-mode  
(9/125 µm)  
*The FT85081 transmitter/FR85081 receiver is classified by the FDA as a Class 1 laser product.  
When using 50/125 µm fiber, subtract 3 dB from the optical power budget.  
††Maximum transmission distance is limited by fiber bandwidth.  
§Maximum transmission distance is based on attenuation of 0.5 dB/km plus a 5 dB buffer for  
connector and splice losses.  
C1648M (4/05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of  
shipment.  
Exceptions to this warranty are as noted below:  
Five years on FT/FR8000 Series fiber optic products.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and  
MC3651H-2X camera models, which have a five-year warranty.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.  
Two years on Spectra®, Esprit®, ExSite, and PS20 scanners, including when used in continuous motion applications.  
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).  
Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and EnduraSeries distributed network-based video  
products.  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.  
Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight  
prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this  
warranty.  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s  
liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products  
shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential  
damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state  
to state.  
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and  
provide the following information:  
1. Model and serial number  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written  
explanation with the product when returned.  
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization  
number (CA number if returned for credit, and RA number if returned for repair).  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate  
address below.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
Service Department  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the  
following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
Pelco  
Pelco c/o Expeditors  
473 Eccles Avenue  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
REVISION HISTORY  
Manual #  
C1648M  
Date Comments  
4/05 Original version.  
Pelco, the Pelco logo, Spectra, Genex, Legacy, Esprit, and Camclosure are registered trademarks of Pelco.  
Endura is a trademark of Pelco.  
©Copyright 2005, Pelco.  
All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Worldwide Headquarters  
3500 Pelco Way  
Clovis, California 93612 USA  
USA & Canada  
Tel: 800/289-9100  
Fax: 800/289-9150  
International  
Tel: 1-559/292-1981  
Fax: 1-559/348-1120  
ISO9001  
United States Canada United Kingdom The Netherlands Singapore Spain Scandinavia France Middle East  
|
|
|
|
|
|
|
|
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peerless Industries TV Mount PF632 User Manual
Philips Car Video System 19OP5 User Manual
Philips Cordless Sander SCB1400NB User Manual
Philips Flat Panel Television LCD Color TV User Manual
Philips Hair Dryer HP8195 00 User Manual
Philips Network Card Network Adaper User Manual
Philips Speaker System MCM149 User Manual
Philips TV VCR Combo CCB193AT99 User Manual
Pioneer Car Amplifier PRS D1000M User Manual
Pioneer Portable DVD Player DV79AVI User Manual