Pentair Water Dispenser S7D75 User Manual

VERTICAL GRID DE FILTERS  
O W N E R ’ S M A N U A L  
INSTALLATION, OPERATION & PARTS  
MODELS  
S7D75  
S8D110  
This manual should be furnished to  
the end user of this filter; its use will  
reduce service calls and chance of in-  
jury and will lengthen filter life.  
Sta-Rite Pool/Spa Group  
U.S. PATENT NO. 4995523 (Other patents pending)  
293 Wright Street, Delavan, WI 53115  
International: 262-728-5551, FAX: 262-728-7550  
Union City, TN • Delavan, WI • Mississauga, Ont. • Murrieta, CA  
© 2004, Sta-Rite Industries  
Printed in U.S.A.  
S284 (Rev. 4/20/04)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
READ AND FOLLOW SAFETY  
INSTRUCTIONS!  
This is the safety alert symbol. When you see this symbol on your filter  
or in this manual, look for one of the following signal words and be alert  
to the potential for personal injury.  
warns about hazards that will cause death, serious personal in-  
jury, or major property damage if ignored.  
warns about hazards that can cause death, serious personal in-  
jury, or major property damage if ignored.  
warns about hazards that will or can cause minor personal injury  
or property damage if ignored.  
NOTICE indicates special instructions not related to hazards.  
Carefully read and follow all safety instructions in this manual and on equip-  
ment. Keep safety labels in good condition; replace if missing or damaged.  
Incorrectly installed or tested equipment may fail, causing  
severe injury or property damage. Read and follow instructions  
in owner's manual when installing and operating equipment.  
Have a trained pool professional perform all pressure tests.  
1. Do not connect system to a high pressure or city water system.  
2. Use equipment only in a pool or spa installation.  
3. Trapped air in system can cause explosion. BE SURE all air is out of system  
before operating or testing equipment.  
Before pressure testing, make the following safety checks:  
• Check all clamps, bolts, lids, and system accessories before testing.  
• Release all air in system before testing.  
• Tighten Sta-Rite pump trap lids to 30 ft. lbs. (4.1 kg-cm) torque for testing.  
• Water pressure for test must be less than 25 PSI (172 kPa).  
• Water Temperature for test must be less than 100o F. (38o C).  
• Limit test to 24 hours. After test, visually check system to be sure it is ready  
for operation. Remove pump trap lid and retighten hand tight only.  
NOTICE: These parameters apply to Sta-Rite equipment only. For  
non-Sta-Rite equipment, consult equipment manufacturer.  
BEFORE WORKING  
ON FILTER:  
If filter clamps are  
1. Stop pump.  
adjusted or removed  
under pressure,  
tank may explode,  
causing severe injury or  
major property damage.  
2. Open air release  
valve.  
3. Release all pressure  
from system.  
BEFORE WORKING  
ON PUMP OR MOTOR  
Filter pumps require  
hazardous voltage  
which can shock, burn,  
or cause death.  
Disconnect power  
to motor at main  
circuit breaker.  
Discharge motor  
capacitor to ground.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERAL INFORMATION  
• Clean a new pool as well as possible before filling pool and operating filter.  
Excess dirt and large particles of foreign matter in the system can cause seri-  
ous damage to the filter and pump.  
• With a diatomaceous earth (DE) filter system in place and operating cor-  
rectly, clean water is returned to the pool faster than pool water is being  
contaminated. A typical pool installation will require approximately one  
week to obtain and maintain the sparkle that your filter is capable of giving  
you.  
• DO NOT use more than the recommended amount of DE in your filter. To  
do so can cause a buildup of DE and "bridging" between the elements  
which will plug the filter.  
If filter is improperly disassembled or assembled, it can explode under  
pressure! To avoid danger of severe injury or major property damage,  
always follow service instructions in this manual when working on filter!  
NEVER operate this filter system at more than 50 pounds per square  
inch (50 PSI/345kPa) pressure! Be sure filter pressure gauge operates  
when system is operating. If pressure gauge is damaged or does not work, re-  
place it.  
Hazardous pressure.  
Can cause severe  
injury or major  
property damage  
from tank blow up.  
Purge all air from system before operating system. NEVER operate filter  
with air trapped inside.  
Release all pressure  
and read instructions  
before working on filter.  
• On a new pool installation, we recommend:  
1. Disassemble the filter after the initial cleanup.  
To prevent severe injury or major property damage, exactly follow "Filter  
Disassembly/Assembly Procedure" on Page 8.  
2. Remove and hose down the element assembly to remove contaminants.  
• It is a good idea to remove the element assembly once a year and soak it in  
a filter cleaning solution to remove accumulated body oils, etc.; see Page  
11, "Chemical Cleaning Procedure".  
• Cleaning interval is based on pressure differential, not on length of time fil-  
ter is operated. Different water conditions will have different normal clean-  
ing intervals. If backwashing filter is not possible, use "Manual Filter  
Cleaning Procedure", Page 10, at regular intervals to clean filter.  
• Check local codes for restrictions on backwash to waste piping, separation  
tank requirements and spent D.E. disposal requirements.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
Installation of filter should only be done by qualified, licensed personnel.  
Filter mount must:  
• Provide weather and freezing protection.  
• Provide space and lighting for easy access for routine maintenance. (See  
Figure 1 and Table II, Page 6, for space requirements.)  
• Be on a reasonably level surface and provide adequate drainage.  
• Be as close to pool as possible to reduce line loss from pipe friction.  
Piping:  
• Piping must conform to local/state plumbing and sanitary codes.  
• Use Teflon tape or Plasto-Joint Stik' on all male connections of plastic pipe  
and fittings. DO NOT use pipe compounds on plastic pipe; it will cause the  
pipe to crack. Do not use sealant on unions—assemble them dry and hand  
tight.  
• Support pipe independently to prevent strains on filter or valve.  
• Use 2” (51mm) pipe to reduce pressure losses as much as possible.  
NOTICE: Filter may be located away from pool, but for adequate flow larger  
pipe may be needed. Check local codes for remote installation.  
• Fittings restrict flow; for best efficiency use fewest possible fittings.  
• Keep piping tight and free of leaks: pump suction line leaks may cause  
trapped air in filter tank or loss of prime at pump; pump discharge line leaks  
may show up as dampness or jets of water.  
NOTICE: Overtightening can crack filter ports.  
TABLE I - Sta-Rite valves for  
use with DE filters  
Valves:  
• A check valve installed ahead of filter inlet will prevent contaminants from  
draining back into pool.  
Port  
Size  
Part  
Number  
• A check valve installed between filter and heater will prevent hot water  
from backing up into filter and deforming internal components.  
Multi-port  
• Install Sta-Rite Two Position Slide Valve or Multiport Selector Valve with fil-  
ter. See Table I.  
2"  
18201-0200*  
Plastic Slide  
• Filter ports and valve ports are furnished with union connections.  
DO NOT use pipe sealants on union collar (nut).  
2"  
WC212-134P*  
* Recommended for best energy  
conservation.  
• Use care before assembly not to damage union sealing surfaces or O Ring.  
To allow recirculation during precoat (if precoat pot is used), install a recir-  
culation line with shut-off between pad return line and pump suction.  
NOTICE: Use of valves  
other than those listed  
above could cause  
reversed water flow  
through filters and  
damage to internal fil-  
ter components.  
Electrical  
• All wiring, grounding and bonding of associated equipment must meet local  
and/or National Electrical Code standards.  
1 Lake Chemical Co., Chicago, IL  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
WATER OUTLET  
TO POOL  
D
A
WATER INLET  
PUMPED  
FROM POOL  
E
C
Figure 2 – Filter Cycle  
B
OUTLET  
INLET  
7.812(198.4)  
9.19(233.4)  
WATER INLET  
PUMPED  
FROM POOL  
2" (51mm)Sta-Rite  
Union Connections  
WASTE PORT TO  
SEPARATION TANK  
FIGURE 1 – Dimensions in inches (mm)  
Figure 3 – Backwash Cycle  
TABLE II - SPACE REQUIREMENTS IN INCHES (MM)  
Model No.  
A
B
C*  
D
E
1
1
S7D75  
S8D110  
28 ⁄2(724)  
42(1067)  
42 ⁄4(1074)  
7
8
36(914)  
40(1020)  
53 ⁄2(1359)  
1
1
1
32 ⁄2(826)  
54 ⁄4(1378)  
8.0  
6.0  
* Number of clamps.  
TABLE III - APPROVED DE  
Use only the following DE or equal:  
4.0  
2.0  
S7D75  
S8D110  
Johns Manville  
GREFCO  
Celite 545  
Dicalite 4200  
Celatom  
0
Eagle-Picher  
0
10 20 30 40 50 60  
Gallons Per Minute  
80 90 100 110 120  
70  
TABLE IV - FILTER SPECIFICATIONS & OPERATING INFORMATION  
Pressure Drop Curve  
Filter Model:  
S7D75  
S8D110  
2
Filter Area in Sq. Ft. (M )  
37 Sq. Ft. (3.44) 53 Sq. Ft. (4.92)  
Lbs. (Kg) of D.E. Used  
3.7 (1.7)  
74 (280)  
72 (280)  
50 (345)  
5.3 (2.4)  
106 (401)  
106 (401)  
50 (345)  
Max. Flow Rate in GPM (LPM)  
NSF Public Pool Flow Rate in GPM (LPM)  
Max. Operating Pressure in PSI (kPa)  
NOTICE: 1/2 pound of DE will fill a one-pound coffee can.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
INITIAL START-UP  
Be sure pump is OFF before starting procedure.  
Do not operate these filters at more than 50 PSI (345 kPa) under any  
circumstances!  
To prevent serious damage to the element fabric, NEVER run  
you DE filter without a diatomaceous earth precoat!  
To avoid damage to internal filter components, never change  
handle position on control valve while pump is running.  
Hazardous pressure.  
Can cause severe  
injury or major  
property damage  
from tank blow up.  
1. Make sure all clamps are in place and knobs are securely hand-tight.  
2. Set valve to 'filter' position.  
Release all pressure  
and read instructions  
before working on filter.  
3. Fill trap on pump with water.  
4. Open air release valve on top of filter assembly (Key No. 3, Page 14).  
5. Start pump to purge air from system.  
6. When steady stream of water comes from air release valve, close the  
valve.  
7. To prepare precoat slurry, mix diatomaceous earth (DE) and water. See  
Table IV or instruction decal on filter shell for amount of DE to use.  
8. Empty slurry slowly into skimmer to precoat filter element with an even  
filtering cake.  
Close valve before air is drawn into system.  
NOTICE: To avoid bridging between filter grids, do not use more DE than 0.1  
pound per square foot of filter area (0.49 kilos per square meter).  
After filter is operating, record filter pressure gauge reading in owner's manual  
for future use.  
NOTICE: When installed on a newly plastered pool, after approximately 48  
hours of operation disassemble filter and clean out plaster dust (see "Manual  
Filter Cleaning Procedure", Page 10).  
To avoid severe injury or major property damage, exactly follow in-  
structions under "System Disassembly/Assembly" (Page 8)!  
Remove and thoroughly clean filter element assembly. Use cleanser or deter-  
gent and a bottle brush to remove plaster dust (see Figures 8 and 9, Page 10).  
When installed on a pool with vinyl liner or painted bottom, thoroughly back-  
wash and clean filter element after 48 hours of operation to remove construc-  
tion debris (see "Filter Backwash Procedure", Page 9).  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
FILTER DISASSEMBLY/  
ASSEMBLY PROCEDURE  
To avoid equipment damage and personal injury, never change  
handle position on control valve while pump is running.  
BEFORE DISASSEMBLING FILTER:  
1. STOP PUMP.  
2. OPEN air release valve and drain fitting.  
3. WAIT until all pressure is released and water drained from filter tank  
and system before loosening clamp knobs.  
Disassembly:  
1. Backwash filter according to instructions under “Filter Backwash  
Procedure”, Page 9.  
2. Stop pump.  
Hazardous pressure.  
Can cause severe  
injury or major  
property damage  
from tank blow up.  
3. Open air release valve (Key No. 3, Page 14) on top of filter tank to release  
all air pressure from inside of tank and system.  
4. Remove filter drain plug and drain all water from tank.  
5. To equalize flange stresses, loosen clamp knobs alternately (that is, on op-  
posite sides of tank) around tank. Remove clamps.  
Release all pressure  
and read instructions  
before working on filter.  
6. Being careful not to damage cord ring (Key No. 21, Page 14), lift upper  
tank shell (Key No. 7, Page 14) off lower tank shell (Key No. 20, Page 14).  
Assembly:  
1. Remove O-Ring slowly to avoid stretching or tearing it.  
2. Inspect O-Ring (Key No. 21, Page 14) for cuts, nicks, etc. If O-Ring is  
damaged, deformed, or has lost its resiliency, replace with a new one.  
3. Clean O-Ring area of tank shell (both halves) and O-Ring.  
4. Carefully install O-Ring and upper tank shell (Key No. 7, Page 14) on tank  
bottom (Key No. 20, Page 14).  
NOTICE: Do not lubricate O-Ring. Lubricants attract dirt and grit and may  
(especially when petroleum based) damage O-Ring and void warranty.  
NOTICE: Be sure upper tank shell contacts O-Ring surface evenly and  
seal area is clean and free from dirt.  
5. Install clamp bolts and clamps. Do not tighten clamps yet.  
6. See Figures 4 and 5 for clamp tightening sequence. Tighten all clamp  
knobs securely hand tight.  
NOTICE: To equalize stresses on tank, be sure to tighten clamps in se-  
quence shown. DO NOT work your way around the filter tightening adja-  
cent clamps.  
7. Install air relief valve and gauge assembly on tank.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING THE FILTER  
When to Clean:  
1
5
4
NOTICE: If installation does not allow backwashing, use manual cleaning proce-  
dure regularly (see Page 10).  
1. With a new filter:  
A. Record filter operating pressure at startup. When pressure reaches 15  
PSI (103kPa) above startup operation pressure, stop pump for 15-30  
seconds to allow filtering cake to release.  
3
6
B. Restart pump to form new cake. Pressure should now be less than 10  
PSI (69kPa) above startup operating pressure.  
2
7
C. If pressure is still more than 10 PSI (69kPa) above startup operating  
pressure, backwash filter (see below).  
FIGURE 4 - 21" Filter clamp tighten-  
ing sequence.  
2. Thoroughly clean air relief filter screen (Key No. 2, Page 15) on top of  
manifold EVERY time filter is opened. Be sure to remove all debris from  
screen. Replace filter screen if damaged.  
3. At least twice a year, manually clean filter according to instructions, Page  
10. At least once a year, follow instructions under "Chemical Filter  
Cleaning Procedure", Page 11, as well.  
1
7
5
Filter Backwash Procedure:  
To prevent equipment damage and possible injury turn pump OFF  
before changing valve position.  
NOTICE: Before backwashing with a separation tank, review separation tank own-  
er's manual for instructions.  
4
3
1. Stop pump.  
2. Change valve position.  
A. If using Multi-port Valve, set to backwash position.  
B. If using Two Position Slide Valve, raise handle to fully extended position.  
6
8
2
3. Start pump, circulating water backwards through filter to flush cake and con-  
taminants into separation tank or waste.  
FIGURE 5 - 25" Filter clamp tight-  
ening sequence.  
4. If system has a sight glass, backwash until water in glass runs clear.  
5. If system does not have a sight glass:  
A. Backwash one minute.  
B. Stop pump; reset valve to 'FILTER' position.  
Stop pump before changing valve setting!  
C. Restart pump; filter for 20 seconds.  
D. Repeat steps A, B, C three times. Cycling is effective when cake and con-  
taminants are difficult to break and flush out of filter.  
NOTICE: Do not vacuum pool while backwashing filter.  
6. Stop pump.  
7. Open air release valve and release ALL pressure from tank and system.  
8. Follow 'Disassembly' procedure, Page 8, to remove top of filter.  
Hazardous pressure. Risk of severe personal injury and  
major property damage if tank is opened while under pressure or while  
pump is running.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. If any DE remains on grids after backwashing, flush filter elements with  
garden hose to remove it. Be sure to comply with local code for waste DE  
disposal.  
10. Follow instructions under 'Assembly', Page 8, to reassemble filter.  
11. Follow 'Initial Start-up' procedure (Page 7, steps 4, 5, 6 and 7) to restart  
system.  
12. Compare pressure reading on gauge with reading recorded after initial  
startup. The two readings should be very close; if not, do "Manual Filter  
Cleaning Procedure", below.  
Hazardous pressure.  
Can cause severe  
injury or major  
property damage  
from tank blow up.  
MANUAL FILTER  
CLEANING PROCEDURE  
Release all pressure  
and read instructions  
before working on filter.  
Before Disassembling Filter:  
1. STOP PUMP.  
2. OPEN air release valve.  
3. WAIT until all pressure is released from filter tank and system  
Manifold  
before loosening clamps.  
NOTICE: At least twice a year, disassemble and clean filter regardless of oper-  
ating pressure readings. This can be done conveniently while winterizing pool  
in cold climates. Use this method regularly if no means of backwashing is  
available.  
Element  
Assembly  
1. Backwash filter as usual, but do not precoat.  
O-Ring  
1216 0497  
2. Disassemble filter (see Page 8).  
Union  
Collar  
To avoid severe injury or major property damage, exactly follow in-  
structions under “Disassembly” (Page 8)!  
3. Unscrew union collar holding element assembly in position.  
NOTICE: Be careful not to lose O-Ring.  
4. Grasp element assembly at manifold (Figure 6) and remove it.  
5. Hose down element assembly and clean with bottle brush (Figure 7). Use  
detergent solution or filter cleanser available from a pool service store.  
NOTICE: To avoid damaging fabric, do not allow filter element to rub on  
concrete or any abrasive surface during cleaning.  
FIGURE 6  
NOTICE: Do not expose element cloth to direct sun for long periods.  
Direct sun will cause the cloth to deteriorate.  
6. Inspect grid cloth for tears, calcification, plugged areas, etc. If necessary,  
soak element in filter cleanser to remove buildup of oils, etc. If calcified,  
consult pool service company or factory for instructions.  
7. Thoroughly clean air relief filter screen (Key No. 2, Page 15) on top of  
manifold. Be sure to remove all debris from screen.  
8. Inspect O-Ring out of the internal union (see Figure 6) for damage.  
Reinstall it in the groove in the union half if it is undamaged; if it shows  
tears or cuts replace it.  
1215 0497  
9. Replace filter element in tank and tighten union firmly hand tight. Union  
FIGURE 7  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
collars may need to be cleaned before reassembly.  
10. Follow filter assembly procedure, Page 8.  
To avoid severe injury or major property damage, exactly follow  
instructions under “Assembly” (Page 8)!  
11. If unit is returning to service, see “Initial Startup”, Page 7.  
12. If cleaning is part of seasonal shutdown, see “Winterizing”, Page 12.  
CHEMICAL CLEANING  
PROCEDURE  
Hazardous pressure.  
Can cause severe  
injury or major  
property damage  
from tank blow up.  
Before Disassembling Filter:  
1. STOP PUMP.  
2. OPEN air release valve.  
3. WAIT until all pressure is released from filter tank and system  
before loosening clamps.  
Release all pressure  
and read instructions  
before working on filter.  
NOTICE: Do not expose element cloth to direct sunlight for long periods.  
Direct sunlight will cause the cloth to deteriorate.  
NOTICE:To avoid damaging fabric, do not allow filter element to rub on con-  
crete or any abrasive surface during cleaning.  
NOTICE: Clean filter manually before doing any chemical cleaning.  
Filter Disassembly:  
To avoid severe injury or major property damage exactly follow  
instructions under “Disassembly” (Page 8)!  
1. Disassemble and inspect element grid assemblies for tears and worn  
areas. Replace as needed.  
2. Rinse each grid thoroughly with water.  
3. Wash each grid with a mild soap solution or commercial filter cleaner. If  
necessary, soak element grids in filter cleanser to remove buildup of oils,  
etc.  
4. Rinse thoroughly to remove all soap film.  
5. If filter elements do not come clean after soaking, have your pool profes-  
sional acid clean them.  
Risk of burns, explosions, and environmental damage. Only  
trained professionals should attempt to acid clean filter elements.  
7. Reassemble element grids.  
8. Inspect inside of filter tank and remove any debris which remains after  
backwashing.  
9. Thoroughly clean air relief filter screen (Key No. 2, Page 15) on top of  
manifold. Be sure to remove all debris from screen. Replace filter screen if  
damaged.  
10. Follow filter assembly procedure, Page 8.  
To avoid severe injury or major property damage, follow instructions  
under “Assembly” (Page 8)!  
11. If unit is returning to service, see “Initial Startup”, Page 7.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
l2. If cleaning is part of seasonal shutdown, see “Winterizing”, Page 12.  
SYSTEM INSPECTION  
General:  
Wash outside of filter with a mild detergent and water. Rinse off with hose.  
NOTICE: DO NOT use solvents to clean filter; solvents may damage plastic  
components in system.  
NOTICE: Open air bleed valve and bleed all air from filter each time pump is  
stopped and restarted.  
Weekly Inspection:  
1. Skimmer basket- remove debris.  
2. Stop pump, release all pressure. Remove trap cover and basket, remove de-  
bris.  
3. Bleed air from filter each time system is started.  
4. For systems with bypass valve, make sure separation tank is not under  
pressure.  
5. Check pump for leaks. If found, see pump owner's manual.  
6. Check pump strainer lid for tightness. Do not over-tighten!  
WINTERIZING  
1. Clean filter according to instructions, Page 10, before winterizing. Do not  
winterize with DE precoat on grids or with residual in tank.  
2. Open air release valve; open all system valves. Position multiport valve  
between port positions to allow passage to all ports.  
3. Remove drain plugs from trap, pump, valve, filter and separation tank.  
4. Drain system piping.  
5. Loosen union nuts to drain water from filter internal piping and valve.  
6. Cover with plastic or tarpaulin to prevent water entrance and freezing.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING GUIDE  
1. Short Cycle between backwashes:  
NOTICE: Time between backwashes will vary with each installation and be-  
tween different areas of the country. The following causes and remedies are  
for cycle times shorter than normal for your area.  
A. Chlorine residual too low; maintain proper residual (consult pool pro-  
fessional for recommendation).  
B. Flow rate too high; restrict flow to rated capacity of filter (see instruc-  
tion plate on filter or specifications on Page 6).  
C. Filter too small; install larger filter or additional filter.  
D.Improper/insufficient precoat; see precoat instructions (Page 7).  
E. Filter elements plugged; thoroughly clean filter (see No. 4, "Plugged  
Grid Cloth", below, and "Manual Filter Cleaning Procedure", Page 10).  
F. Insufficient cleaning during backwash or annual cleaning; review  
cleaning instructions, Pages 9-11.  
G.Too much DE; check for bridging between filter elements.  
H.Water is chemically out of balance; consult pool professional.  
2. Low Flow/High Pressure:  
A. Elements plugged; clean filter thoroughly (see Pages 9-11).  
B. Pipe blocked downstream from filter; remove obstruction.  
C. Piping too small; use larger pipe (consult dealer for sizing).  
D.Filter area too small; install larger filter or auxiliary filter (consult dealer  
for recommendation)  
3. Low Flow/Low Pressure:  
A. Pump too small; consult dealer for recommendations.  
B. Plugged pump or plugged hair and lint trap; clean thoroughly.  
4. Plugged Grid Cloth:  
A. Insufficient precoat; see precoat instructions (Page 7).  
B. Insufficient cleaning; follow cleaning instructions closely and clean  
thoroughly (see Pages 9-11).  
C. Water is chemically out of balance; consult pool service man.  
D.Excessive air in filter; non-precoated areas may plug. Vent air from tank  
and check for pump suction pipe leaks. Clean air bleed filter in grid as-  
sembly.  
5. Pool Water Not Clean:  
A. Chlorine dosage too low; maintain adequate chlorine residual (consult  
pool service man for recommendation).  
B. Broken filter elements passing DE into pool; replace defective grids.  
C. Insufficient or improper precoat; follow precoating instructions and use  
recommended amount of DE (see Page 7).  
D.Inadequate turnover rate; consult dealer to verify that equipment is  
properly sized for your pool.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODELS  
S7D75  
S8D110  
2
21  
2
5
3
0
2
0
3
5
1
5
0
1
1
5
4
5
0
5
0
5
5
3
0
6
4
5
6
8
7
9
20  
10  
19  
17  
11  
18  
12  
14 13  
16  
14  
15  
1460 0497  
REPAIR PARTS LIST  
Model No.  
Key  
No.  
Part  
Description  
S7D75  
S8D110  
1
2
3
4
5
6
7
8
2 Inch Gauge  
33600-0023  
WC212-120P  
U37-16P  
24900-0504  
35505-1423  
24851-9000  
23900-1220  
U9-362  
33600-0023  
WC212-120P  
U37-16P  
24900-0504  
35505-1423  
24851-9001  
23900-1221  
U9-362  
Air Release Valve  
Close Nipple 1/4 in.  
Adapter Bushing  
O-Ring  
Upper Tank Shell Kit*  
Filter Element Assembly  
O-Ring  
9
Outlet Assembly  
Inlet Assembly  
O-Ring  
1-1/2" NPT Plug  
Adapter Fitting  
O-Ring  
23911-0102  
23911-0100  
35505-1425(2)  
27001-0022S  
24900-0509  
35505-1424 (2)  
24900-0503  
24752-0050(2)  
24850-0101 (7)  
24850-0010(7)  
24850-0102  
24850-0008  
24850-0105  
32165-4004  
32155-4031  
32155-4032  
23911-0102  
23911-0101  
35505-1425(2)  
27001-0022S  
24900-0509  
35505-1424(2)  
24900-0503  
24752-0050(2)  
24850-0101 (8)  
24850-0010(8)  
24851-0103  
24850-0009  
24850-0105  
32165-4005  
32155-4033  
32155-4034  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
Drain Plug  
Bulkhead Retaining Nut  
Clamp Assembly  
Clamp Bolt  
Lower Tank Shell  
Tank O-Ring  
Valve and Gauge Assembly (Includes Key Nos. 1-5)  
Warning Decal  
Decal - Model Label  
Decal - Instruction Label  
Not illustrated  
Quantity one unless otherwise indicated ( ).  
* Includes all decals and labels.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
2
FILTER ELEMENT ASSEMBLY FOR S7D75  
3
Key  
No.  
Part  
No.  
Part No.  
Description  
Used  
23900-1220  
4
5
1
2
3
4
5
6
7
8
9
Wing Nut  
2
1
1
1
2
2
2
2
2
1
2
35402-0074  
24800-0120  
24800-0100  
23900-1171  
23900-1170  
23900-0033  
23900-1174  
23900-1175  
23900-1173  
23900-0350  
23900-0039  
6
7
Air Bleed Assembly  
Manifold  
8
9
Covered Element 12-7/16"  
Covered Element 13-13/16"  
Covered Element 16-1/2"  
Covered Element 15-3/16"  
Covered Element 12-7/16"  
Covered Element 9-11/16"  
Element Grid Support  
Rod  
1063 0497  
10  
11  
10  
11  
1
2
FILTER ELEMENT ASSEMBLY FOR S8D110  
3
Key  
No.  
Part  
Description  
No.  
Used  
Part No.  
23900-1221  
4
5
1
2
3
4
5
6
7
8
9
Wing Nut  
Air Bleed Assembly  
Manifold  
Covered Element 16-1/2"  
Covered Element 19-5/16"  
Covered Element 16-1/2"  
Covered Element 15-3/16"  
Covered Element 11"  
Element Grid Support  
Rod  
2
1
1
3
4
2
2
2
1
2
35402-0074  
24800-0120  
24801-0101  
23900-1172  
23900-0144  
23900-0033  
23900-1174  
23900-0032  
23901-0350  
23900-0039  
6
7
8
1064 0497  
9
10  
10  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STA-RITE LIMITED WARRANTY  
Pumps, filters, skimmers, underwater lights (except bulbs),  
* Full warranty coverage is in effect for one year after instal-  
lation. The pro-rated warranty covers the tank only during  
the 2nd through 10th year after installation. The amount cov-  
ered decreases by 10% each year. (ie., 2nd year 90% covered,  
3rd year 80% covered, etc.).  
accessories and fittings manufactured by Sta-Rite are war-  
ranted to be free of defects in material and workmanship for  
one (1) year from date of installation.  
Year from date  
Product specific warranties:  
of installation  
The foregoing warranties relate to the original consumer pur-  
chaser (“Purchaser”) only. Sta-Rite shall have the option to re-  
pair or replace the defective product, at its sole discretion.  
Purchasers must pay all labor and shipping charges necessary  
to replace the product covered by this warranty. Requests for  
warranty service must be made through the installing dealer.  
This warranty shall not apply to any product that has been  
subject to negligence, misapplication, improper installation  
or maintenance, or other circumstances which are not in  
Sta-Rite’s direct control.  
HRPB, DEPB, System 3, and PL – Tanks . . . . . . . .10 years  
Internal filter components and valves . . . . . . . . . 1 year  
Max-E-Therm – Pool/Spa Heaters . . . . . . . . . . . . . 2 years  
Heater Enclosure only (Upper RH & LH;  
lower enclosure; and control board enclosure)… 10 years  
Automatic Pool Cleaners including Hose . . . . . . . 2 years  
Cristal-Flo filters – Tanks . . . . . . . . . . . .10 years pro-rated*  
Valve and internal components. . . . . . . . . . . . . . . . 1 year  
This warranty sets forth Sta-Rite’s sole obligation and  
Purchaser’s exclusive remedy for defective products.  
Posi-Flo II – Tanks . . . . . . . . . . . . . . . . . . . . . . . . . .10 years  
Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year  
STA-RITE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL,  
INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER.  
PRC Cartridge –  
Filter Tanks . . . . . . . . . .5 years pro-rated (1st 2 years full)  
Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year  
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN  
LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WAR-  
RANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED  
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A  
PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE  
DURATION OF THE APPLICABLE EXPRESS WARRANTIES  
PROVIDED HEREIN.  
System 2 Above Ground Systems – Tanks . . . . . . .10 years  
Pumps / Platform and Internals . . . . . . . . . . . . . . . 1 year  
Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year  
When equipped with A.O. Smith  
2-compartment motors (Does not include  
pumps sold as part of a systems package) . . . . . . 2 years  
Some states do not allow the exclusion or limitation of inci-  
dental or consequential damages or limitations on how long  
an implied warranty lasts, so the above limitations or exclu-  
sion may not apply to you. This warranty gives you specific  
legal rights and you may also have other rights which vary  
from state to state.  
Traps / In-Line Strainers . . . . . . . . . . . . . . . . . . . . . 1 year  
Vertical Commercial Filter – Tanks . . . . . . . . . . . .10 years  
Internals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year  
Horizontal Commercial Filter  
Supersedes all previous publications.  
Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 years  
(Years 6-9, Prorated declining 20%/year, Yr. 10 - 10%)  
Internals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year  
Sta-Rite Industries  
293 Wright St., Delavan, WI 53115  
Retain Warranty Certificate (upper portion) in a safe and convenient location for your records.  
DETACH HERE: Fill out bottom portion completely and mail within 10 days of purchase/installation to:  
Sta-Rite, Attn: Warranty Dept., 293 Wright St., Delavan, WI 53115  
Warranty Registration Card  
Name  
Years pool has been in service less than 1 1-3 3-5 5-10  
Purchased from:  
Company name  
Address  
City  
State  
Zip  
Address  
Purchase Date  
Product Purchased  
New installation  
City  
State  
Zip  
Please send me more information on these  
other products from Sta-Rite.  
Replacement  
Type of Pool  
Size of Pool  
Inground  
Vinyl  
Fiberglass  
Gunite  
Pumps Filters Automatic Pool Cleaners  
Maintenance Equipment Test Strips  
Heaters  
S4877PS (Rev. 2/4/03)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Music Mixer 900 Mixer User Manual
Peavey Music Mixer ICA 1200 User Manual
Philips CRT Television 15 AA3330 User Manual
Philips Portable DVD Player PET831 12 User Manual
Philips Switch PIP3207 DC User Manual
Pioneer Portable Speaker S 7EX User Manual
Pioneer Universal Remote BR 360 User Manual
Polk Audio Speaker AB755c User Manual
Precor Treadmill C962i User Manual
PVI Industries Water Heater 199 SS A PN User Manual