SD5 Series
Spectra II™ and
Spectra Lite™
Dome Systems
Installation Manual
C1487M-H (1/01)
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel +1(559) 292-1981 • FAX +1(559) 348-1120
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
Section
Page
IMPORTANT SAFEGUARDS AND WARNINGS.................................................................................................................... 4
INSTALLATION .......................................................................................................................................................................5
HARD CEILING INSTALLATION.................................................................................................................................... 6
SUSPENDED CEILING INSTALLATION ....................................................................................................................... 8
PENDANT-MOUNT INSTALLATION ............................................................................................................................. 10
SURFACE-MOUNT INSTALLATION ............................................................................................................................. 12
TROUBLESHOOTING ...........................................................................................................................................................14
APPENDIX .............................................................................................................................................................................15
SPECIFICATIONS .................................................................................................................................................................19
CERTIFICATIONS AND REGULATORY NOTICES .......................................................................................................23
WARRANTY AND RETURN INFORMATION ........................................................................................................................24
LIST OF ILLUSTRATIONS
Figure
Page
SD5 Series Dimension Drawing ............................................................................................................................20
1
LIST OF TABLES
Table
Page
A
B
C
D
E
Video Coaxial Cable Wiring Distances ..................................................................................................................15
24 VAC Wiring Distances .......................................................................................................................................15
Switch Settings for SW1 ........................................................................................................................................15
Switch Settings for SW2 – P-Type Control ............................................................................................................16
Switch Settings for SW2 – D-Type Control ............................................................................................................16
Pelco Installation Manual C1487M-H (1/01)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it
must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to
verify the exposed parts have not been connected to line circuitry.
5. The installation method and materials should be capable of supporting four times the weight of the enclosure, pan/tilt, camera and
lens combination.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present within
this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
DO NOT OPEN.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
MEASURES DE SECURITE IMPORTANTES
Avant d’installer ou d’utiliser ce produit, les mesures de sécurité suivantes sont à prendre:
1. Toute installation et réparation devraient être entreprises par un technicien qualifié et conformes au codes locaux.
2. A moins que cet equipement indique avoir un boitié agrée NEMA de type 3, 3R, 3S, 4, 4X, 6 ou 6P, il est uniquement conçu pour
utilisation intérieure et ne peut donc pas être en contact de pluie ou d’humidité.
3. Utiliser seulement les pièces de rechanges recommandées par Pelco.
4. Après toute installation ou réparation de la partie électrique de ce produit, une résistance entre le courant et la partie exposée devrait
être installée afin de vérifier que la partie électrique n’aie pas été en contact d’un court circuit.
5. L’installation entreprise et le matériel utilisé devraient supporter quatre fois le poids du boitié, de la tourelle, de la caméra, et de la
lentille.
Ce produit et/ou le manuel pourrait inclurent les symbols suivants:
Ce symbol indique qu’un voltage dangereux
pouvant provoquer un chock électrique est
présant dans cette unité.
CAUTION:
RISQUE DE CHOQUE ÉLECTRIQUE.
NE PAS OUVRIR.
Ce symbol indique qu’il y a des mesures
d’installation et d’entretient importantes
inclus dans le manuel de cet équipement.
Nous vous prions de bien vous familiarisez avec la manuel avant d’entreprendre toute installation.
4
Pelco Installation Manual C1487M-H (1/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
The Spectra II™ dome and Spectra Lite™ dome shipping cartons contain three boxes. Inspect each box to make sure all parts are
present.
IN-CEILING MODELS
Back Box
PENDANT MODELS
Back Box
1
1
Back box
Parts bag
1
1
Back box
Tube of thread compound
1
Conduit fitting
Dome Drive
1
1
1
4
Safety chain bracket
Lock nut
Compass tool
T-rail clip (clip, L-bracket, screw, lock washer and nut)
1
Dome drive
Lower Dome
1
1
Acrylic lower dome with trim ring
Parts bag (O-ring and lubricant, and tube of Loctite)
Dome Drive
1
Dome drive
Lower Dome
1
Acrylic lower dome with trim ring
BACK BOX
BACK BOX
DOME DRIVE
DOME DRIVE
LOWER DOME
LOWER DOME
COMPASS TOOL
SAFETY BRACKET
T-RAIL CLIP
CONDUIT FITTING & LOCK NUT
THREAD LOCTITE®
COMPOUND 222MS
O-RING
LUBE
O-RING
Pelco Installation Manual C1487M-H (1/01)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
HARD CEILING INSTALLATION
IN-CEILING MODELS
STEP 1 - PREPARE CEILING
a. Locate the center point of the mounting location. Drill a hole in
the ceiling using a 3/32-inch drill. Insert the compass tool into
the hole.
b. Draw a circle on the ceiling using the compass tool and a
pencil. Cut the circle out of the ceiling.
STEP 2 - INSTALL THE BACK BOX
ATTACH SAFETY CHAIN HERE
a. Attach the conduit fitting, lock nut, and safety chain bracket.
Install a safety chain/cable (not supplied) that will support up
to 16 pounds (7.3 kg).
b. Turn the thumb screw and open the hinged door to the back
box. Pull wiring into the back box through the conduit fitting.
Refer to Tables A and B in the Appendix for wiring distances.
CEILING TILE
c. Compress the spring clips on the back box and push it through
the hole, until the clips spring back. Tighten the screws until
you hear a clicking noise.
6
Pelco Installation Manual C1487M-H (1/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
24 VAC
TRANFORMER
POWER
(24 VAC ONLY)
CONTROLLER
VIDEO IN
d. Attach the wiring to the circuit board inside the back box. When
finished, close the door to the back box and turn on the power.
The red LED will light.
COAXITRON
VIDEO OUT
CONTROLLER
TX-
TX+
RX-
RX+
TX-
TX+
2 WIRE
CONTROLLER
CONTROL
(RS-422)
NOT USED
NOT USED
IMPORTANT: If the LED does not light, refer to the Trouble-
1
2
3
4
5
6
7
shooting section.
ALARM
INPUTS
SPECTRA II ONLY
NOTE: Aux 1 - Maximum 2A at low voltage (<40V)
Aux 2 - Maximum 150 vA at 32 VDC
GROUND
SWITCHES
(WIRING EXAMPLE)
+5 to +24 VDC
+5 VDC
(NO)
RELAY
(AUX 1)
(NC)
GROUND
LOGIC GATE
(WIRING EXAMPLE)
AUX 2
HEATER/FAN
(NOT USED)
AUX 2
EXTERNAL RELAY
(WIRING EXAMPLE)
STEP 3 - INSTALL DOME DRIVE
SW1
SW2
ON
1
ON
1
2
2
3
3
4
4
6
6
5
5
7
7
8
8
LABEL
SW1
RED
TAB
SW2
GREEN
TAB
LABEL
SW2
RS-422 TERMINATION SWITCH
00303
a. Set the DIP switches for SW1 and SW2 on the bottom of the
dome drive for the appropriate receiver address. Refer to the
labels on the dome drive or Tables C through E in the Appen-
dix in the back of this manual.
c. Line up the green and red tabs with the green and red labels.
Push in on the tabs. Insert the side with the green tab, then the
side with red tab. Continue pushing on the ends of the tabs
until both sides click into place.
b. Daisy Chain Operation Only – When connecting more than
one Spectra dome system to a single controller, terminate the
last unit in the chain (farthest from the controller). To terminate
the dome drive set the RS-422 termination switch to the left.
STEP 4 - INSTALL LOWER DOME
a. Snap the clip, on the end of the trim ring leash, into the hole on the
lip of the back box.
b. Line up the snaps on the trim ring with the mounting screws on the
back box. Snap the trim ring into the plastic snap washers on the
mounting screws.
TO USE YOUR DOME, REFER TO THE
OPERATION AND PROGRAMMING MANUAL.
Pelco Installation Manual C1487M-H (1/01)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
SUSPENDED CEILING INSTALLATION
IN-CEILING MODELS
STEP 1 - PREPARE CEILING TILE
NOTE: The ceiling tile cannot be thinner than 0.50-inch (1.27 cm) or thicker than 1.75-inches (4.45 cm).
a. Remove the ceiling tile from the ceiling. Insert the compass tool (supplied) into the center of the tile. (If necessary use a 3/32-inch bit
to drill a hole.)
b. Draw a circle on the tile using the compass tool and a pencil. Cut the circle out of the ceiling tile.
STEP 2 - INSTALL THE BACK BOX
ATTACH SAFETY CHAIN HERE
a. Attach the conduit fitting, lock nut, and safety chain bracket.
Install a safety chain/cable (not supplied) that will support up
to 16 pounds (7.3 kg).
b. Turn the thumb screw and open the hinged door to the back
box. Pull wiring into the back box through the conduit fitting.
Refer to Tables A and B in the Appendix for wiring distances.
CEILING TILE
T-RAIL CLIP
FOR
CEILING TILE
T-RAIL CLIP
FOR
CEILING TILE
c. Compress the spring clips on the back box and push it through
the hole, until the clips spring back. Tighten the screws until
you hear a clicking noise.
d. Install the ceiling tile with the back box. Attach a T-rail clip on
each side of the ceiling tile. Fasten the L-bracket to the clip
with the supplied screw and washers.
8
Pelco Installation Manual C1487M-H (1/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
24 VAC
POWER
e. Attach the wiring to the circuit board inside the back box. When
finished, close the door to the back box and turn on the power.
The red LED will light.
TRANFORMER
(24 VAC ONLY)
CONTROLLER
VIDEO IN
COAXITRON
CONTROLLER
VIDEO OUT
TX-
TX+
RX-
RX+
TX-
TX+
IMPORTANT: If the LED does not light, refer to the Trouble-
shooting section.
2 WIRE
CONTROLLER
CONTROL
(RS-422)
NOT USED
NOT USED
NOTE: Aux 1 - Maximum 2A at low voltage (<40V)
Aux 2 - Maximum 150 vA at 32 VDC
1
2
3
4
5
6
7
ALARM
INPUTS
SPECTRA II ONLY
GROUND
SWITCHES
(WIRING EXAMPLE)
+5 to +24 VDC
+5 VDC
(NO)
RELAY
(AUX 1)
(NC)
GROUND
LOGIC GATE
(WIRING EXAMPLE)
AUX 2
HEATER/FAN
(NOT USED)
AUX 2
EXTERNAL RELAY
(WIRING EXAMPLE)
STEP 3 - INSTALL DOME DRIVE
SW1
SW2
ON
1
ON
1
2
2
3
3
4
4
6
6
5
5
7
7
8
8
LABEL
SW1
RED
TAB
SW2
GREEN
TAB
LABEL
SW2
RS-422 TERMINATION SWITCH
00303
a. Set the DIP switches for SW1 and SW2 on the bottom of the
dome drive for the appropriate receiver address. Refer to the
labels on the dome drive or Tables C through E in the Appen-
dix in the back of this manual.
c. Line up the green and red tabs with the green and red labels.
Push in on the tabs. Insert the side with the green tab, then the
side with red tab. Continue pushing on the ends of the tabs
until both sides click into place.
b. Daisy Chain Operation Only – When connecting more than
one Spectra dome system to a single controller, terminate the
last unit in the chain (farthest from the controller). To terminate
the dome drive set the RS-422 termination switch to the left.
STEP 4 - INSTALL LOWER DOME
a. Snap the clip, on the end of the trim ring leash, into the hole on the
lip of the back box.
b. Line up the snaps on the trim ring with the mounting screws on the
back box. Snap the trim ring into the plastic snap washers on the
mounting screws.
TO USE YOUR DOME, REFER TO THE
OPERATION AND PROGRAMMING MANUAL.
Pelco Installation Manual C1487M-H (1/01)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
PENDANT-MOUNT INSTALLATION
PENDANT MODELS
STEP 1 - MOUNT AND INSTALL THE BACK BOX
NOTE: If installing outdoors make sure the installation is properly sealed to keep moisture out.
a. Install the mount for the pendant dome. Refer to the instruc-
tions supplied with the mount. Bring the wiring for the dome
through the mount. Refer to Tables A and B in theAppendix for
wiring distances.
b. Turn the thumbscrew and open the hinged door located inside
the back box.
c. Pull wiring from the mount into the back box.
d. Screw the back box into the mount. If outdoors, apply thread
compound (provided) to the threads on the back box.
24 VAC
TRANFORMER
POWER
(24 VAC ONLY)
STEP 2 - WIRE CIRCUIT BOARD
CONTROLLER
VIDEO IN
COAXITRON
Attach the wiring to the interconnect circuit board inside the back
box. Close the door to the back box. Turn on power to the back
box. The red LED will light.
VIDEO OUT
CONTROLLER
TX-
TX+
RX-
RX+
TX-
2 WIRE
CONTROLLER
CONTROL
(RS-422)
NOT USED
NOT USED
TX+
IMPORTANT: If the LED does not light, refer to the Trouble-
shooting section.
1
2
3
4
5
6
7
ALARM
INPUTS
SPECTRA II ONLY
NOTE: Aux 1 - Maximum 2A at low voltage (<40V)
Aux 2 - Maximum 150 vA at 32 VDC
GROUND
SWITCHES
(WIRING EXAMPLE)
+5 to +24 VDC
+5 VDC
(NO)
RELAY
(AUX 1)
(NC)
GROUND
LOGIC GATE
(WIRING EXAMPLE)
AUX 2
HEATER/FAN
(NOT USED)
AUX 2
EXTERNAL RELAY
(WIRING EXAMPLE)
10
Pelco Installation Manual C1487M-H (1/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
STEP 3 - INSTALL DOME DRIVE
SW1
SW2
ON
1
ON
1
2
2
3
3
4
4
6
6
5
5
7
7
8
8
LABEL
SW1
RED
TAB
SW2
GREEN
TAB
LABEL
SW2
RS-422 TERMINATION SWITCH
00303
a. Set the DIP switches for SW1 and SW2 on the bottom of the
dome drive for the appropriate receiver address. Refer to the
labels on the dome drive or tables C through E in theAppendix
in the back of this manual.
last unit in the chain (farthest from the controller). To terminate
the dome drive set the RS-422 termination switch to the left.
c. Line up the green and red tabs with the green and red labels.
Push in on the tabs. Insert the side with the green tab, then the
side with red tab. Continue pushing on the ends of the tabs
until both sides click into place.
b. Daisy Chain Operation Only – When connecting more than
one Spectra dome system to a single controller, terminate the
STEP 4 - INSTALL LOWER DOME
LEASH
ATTACH
LEASH TO
NEAREST
RETAINER
SCREW
MOUNTING
SCREW HOLES
FRONT & BACK
b. Attach the back box trim leash to the lower dome. Use retainer
screw (nearest to a mounting screw) inside lower dome.
a. Lightly apply O-ring lubricant to the O-ring. Install the O-ring in
the groove on the trim ring of the lower dome.
NOTE: If you are install-
ing an outdoor model,
plug the two-pin heater
connection in the lower
dome into the mating
connector in the back
box.
c. Remove the two lower dome, mounting screws. Apply a drop
of Loctite 222MS (supplied) to each screw.
d. Push the lower dome inside the back box, line up the mounting
screw holes, and install the two mounting screws.
TO USE YOUR DOME, REFER TO THE OPERATION AND PROGRAMMING MANUAL.
Pelco Installation Manual C1487M-H (1/01)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
SURFACE-MOUNT INSTALLATION
PENDANT MODELS
STEP 1 - REMOVE THE TOP PORTION OF THE BACK BOX
a. Turn the thumbscrew and open the
hinged door located inside the back box.
b. Unscrew the three Phillips screws lo-
cated underneath the hinged door.
c. Remove the top portion of the back box.
STEP 2 - PREPARE SURFACE AND INSTALL THE BACK BOX
NOTE: If installing outdoors
apply a sealant between the
back box and the mounting
surface
a. Determine the mounting location. Use the base of the back box as a template. Mark the fastener and center hole positions onto the
mounting surface.
b. Drill a hole in the center of the mounting surface. Pull wiring through the opening. Refer to Tables A and B in the Appendix for wiring
distances. Prepare the holes for the fasteners. Position the back box over the mounting holes and pull wiring into the back box.
Secure the back box to the mounting surface using the appropriate hardware for your installation.
24 VAC
TRANFORMER
POWER
(24 VAC ONLY)
CONTROLLER
VIDEO IN
STEP 3 - WIRE CIRCUIT BOARD
COAXITRON
CONTROLLER
VIDEO OUT
Attach the wiring to the interconnect circuit board inside the back
box. Close the door to the back box. Turn on power to the back
box. The red LED will light.
TX-
TX+
RX-
RX+
TX-
TX+
2 WIRE
CONTROLLER
CONTROL
(RS-422)
NOT USED
NOT USED
1
2
3
4
5
6
7
IMPORTANT: If the LED does not light, refer to the Trouble-
ALARM
INPUTS
SPECTRA II ONLY
shooting section.
NOTE: Aux 1 - Maximum 2A at low voltage (<40V)
Aux 2 - Maximum 150 vA at 32 VDC
GROUND
SWITCHES
(WIRING EXAMPLE)
+5 to +24 VDC
+5 VDC
(NO)
RELAY
(AUX 1)
(NC)
GROUND
LOGIC GATE
(WIRING EXAMPLE)
AUX 2
HEATER/FAN
(NOT USED)
AUX 2
EXTERNAL RELAY
(WIRING EXAMPLE)
12
Pelco Installation Manual C1487M-H (1/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
STEP 4 - INSTALL DOME DRIVE
SW1
SW2
ON
1
ON
1
2
2
3
3
4
4
6
6
5
5
7
7
8
8
LABEL
SW1
RED
TAB
SW2
GREEN
TAB
LABEL
SW2
RS-422 TERMINATION SWITCH
00303
a. Set the DIP switches for SW1 and SW2 on the bottom of the
dome drive for the appropriate receiver address. Refer to the
labels on the dome drive or Tables C through E in the Appen-
dix in the back of this manual.
last unit in the chain (farthest from the controller). To terminate
the dome drive set the RS-422 termination switch to the left.
c. Line up the green and red tabs with the green and red labels.
Push in on the tabs. Insert the side with the green tab, then the
side with red tab. Continue pushing on the ends of the tabs
until both sides click into place.
b. Daisy Chain Operation Only – When connecting more than
one Spectra dome system to a single controller, terminate the
STEP 5 - INSTALL LOWER DOME
LEASH
ATTACH
LEASH TO
NEAREST
RETAINER
SCREW
MOUNTING
SCREW HOLES
FRONT & BACK
a. Lightly apply O-ring lubricant to the O-ring. Install the O-ring in
the groove on the trim ring of the lower dome.
b. Attach the back box trim leash to the lower dome. Use the
retainer screw (nearest to a mounting screw) inside lower dome.
NOTE: If you are install-
ing an outdoor model,
plug the two-pin heater
connection in the lower
dome into the mating
connector in the back
box.
c. Remove the two lower dome, mounting screws. Apply a drop
of Loctite (supplied) to each screw.
d. Push the lower dome inside the back box, line up the mounting
screw holes, and install the two mounting screws.
TO USE YOUR DOME, REFER TO THE OPERATION AND PROGRAMMING MANUAL.
Pelco Installation Manual C1487M-H (1/01)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
Unit does not operate.
The controller is not
communicating with the
Spectra unit.
Check to see if the red LED on the circuit
board in the back box is lit.
1. The red LED is not lit.
a. Fuse is bad.
a. Check fuse on the circuit board. Replace fuse if
it is bad. To order a fuse from Pelco, specify the
part number FUS1.6-5X20FAST. This is a 1.6-
ampere fuse, 5 x 20 mm, fast blow.
b. 24 VAC power source is not con-
nected or back box is bad.
b. Use a voltmeter to check if 24 VAC is getting to
the power connector on the circuit board. If NO,
check your power supply. If YES, return the back
box to the factory for repair.
2. The red LED is lit.
a. Wiring is incorrect or is not fully
seated.
a. Check all connections to the circuit board.
Make sure that all connections are fully seated
and the board is wired correctly.
b. DIP switch settings are incorrect.
b. Check the DIP switch settings on the dome
drive (refer to Tables C, D, and E). If the unit still
does not operate, turn off power and replace
the dome drive with a good unit, if you have a
spare. Check the switch settings on the substi-
tute dome drive before installing it. (If you do not
have a spare, return the dome drive and back
box to the factory.) If you substituted a dome
drive and the unit operates, the original
dome drive is bad (return the dome drive to the
factory). If the unit still does not operate,
then the circuit board is bad (return the back
box to the factory).
Fan does not operate.
Fan connections are not fully seated.
Cameras are out of phase.
Make sure the connector for the fan is fully seated.
If the fan still does not operate, return the back box
and dome drive to the factory for repair.
Vertical roll on monitor
when switching between
cameras.
If you are wiring more than one dome to the same
transformer, it is important to wire the power con-
nector in each dome the same way. That is, the
wiring from one side of the transformer must be
connected to the same connector on each dome.
DOME 1
POWER
WARNING: Make
sure you wire power
to the outer connec-
tors of the terminal
block and ground to
the middle connec-
DOME 2
POWER
tor. Otherwise, you
could damage the
DOME 3
POWER
dome.
14
Pelco Installation Manual C1487M-H (01/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX
Table A. Video Coaxial Cable Wiring Distances
Cable Type*
Maximum Distance
RG59/U
RG6/U
RG11/U
750 ft (229 m)
1,000 ft (305 m)
1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance. All-copper center conductor.
95% braided copper shield.
Table B. 24 VAC Wiring Distances
The following are the recommended maximum distances for 24 VAC with a 10-
percent voltage drop. (Ten percent is generally the maximum allowable voltage
drop for AC-powered devices.)
Wire Gauge
20
18
16
14
12
10
30 vA
75 vA
94 ft
(28 m)
150 ft
(45 m
238 ft
(115 m)
380 ft
(72 m)
603 ft
(183 m)
960 ft
(292 m)
37 ft
60 ft
95 ft
152 ft
241 ft
384 ft
(11 m)
(18 m)
(29 m)
(46 m)
(73 m)
(117 m)
NOTE: Input power for the dome is 24 VAC only. Power consumption is 30 vA per
dome for indoor models and 75 vA for outdoor models.
Use a 24 VAC transformer with the following minimum vA:
40 vA per dome
100 vA per dome
For indoor models (without heater)
For outdoor models (with heater)
Table C. Switch Settings for SW1
Control Type
Switch Setting
SW1-4
OFF
SW1-1
OFF
ON
SW1-2
OFF
OFF
ON
SW1-3
OFF
SW1-5
OFF
SW1-6
OFF
SW1-7
OFF
SW1-8
OFF**
OFF**
OFF**
Coaxitron®
P-Type Control
D-Type Control
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF*
NOTES: Switches SW 1-3 through SW 1-6 MUST be OFF.
D-type control is RS-422 that is compatible with Pelco’s CM6700, MPT9500, CM8500, and Genex® controllers or with
American Dynamics control systems using the AD2083 Translator.
P-type control is RS-422 that is compatible with Pelco’s CM6700/CM9750/CM9760 and Genexcontrol systems.
* OFF- Use with controllers that have more than 32 presets.
ON- Use with American Dynamics controllers (32 presets).
** OFF - Use with all control systems except CM9502 with variable speed keyboards.
For CM9502 with fixed speed keyboards, set switch OFF.
ON - Use with CM9502 with variable speed keyboards for smoother joystick control.
Pelco Installation Manual C1487M-H (01/01)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Table D. Switch Settings for SW2 – P-Type Control
NOTE: For Coaxitron controls, SW2 is not used; set all switches OFF. For D-type control systems, refer to Table E.
Receiver
Address
Switch Setting
SW2-3
Receiver
Address
Switch Setting
SW2-3
SW2-1
SW2-2
SW2-4
SW2-5
SW2-1
SW2-2
SW2-4
SW2-5
1
2
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
3
OFF
ON
OFF
ON
4
ON
ON
5
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
6
ON
ON
7
OFF
ON
ON
OFF
ON
ON
8
ON
ON
ON
ON
9
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
10
11
12
13
14
15
16
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
Baud Rate
Switch Setting
SW2-6
SW2-7
SW2-8
2400
4800
9600
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
Table E. Switch Settings for SW2 – D-Type Control
NOTE: For Coaxitron controls, SW2 is not used; set all switches OFF. For P-type control systems, refer to Table D.
Receiver
Address
Switch Setting
Receiver
Address
Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
1
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
3
ON
ON
ON
ON
4
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
5
ON
ON
ON
ON
6
OFF
ON
ON
OFF
ON
ON
ON
ON
7
ON
ON
ON
ON
ON
ON
8
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
9
ON
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
(Continued on next page)
16
Pelco Installation Manual C1487M-H (01/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table E. Switch Settings for SW2 – D-Type Control (continued)
Receiver
Address
Switch Setting
Receiver
Address
Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
(Continued on next page)
Pelco Installation Manual C1487M-H (01/01)
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Table E. Switch Settings for SW2 – D-Type Control (continued)
Receiver
Address
Switch Setting
Receiver
Address
Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
18
Pelco Installation Manual C1487M-H (1/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
MECHANICAL
Construction
Back box:
Aluminum
Dome drive:
Lower dome:
Aluminum, ABS plastic
Acrylic
Cable Entry
In-Ceiling:
Pendant:
.75-inch (1.91 cm) conduit fitting
Through 1.5-inch (3.81 cm) NPT pendant mount
Pan Movement:
Vertical Tilt:
360° continuous pan rotation
Unobstructed +2° to -92°
Manual Pan/Tilt Speeds*
Pan
Spectra II:
Spectra Lite:
Tilt
0.1°-80°/sec manual operation, 150°/sec turbo
0.5°-80°/sec manual operation, 150°/sec turbo
Spectra II:
Spectra Lite:
0.1°-40°/sec
0.5°-40°/sec
Preset Speeds
Pan:
Tilt:
250°/sec
200°/sec
* For variable-speed operation an appropriate controller is required. With fixed-speed controllers, Spectra II and Spectra Lite pan/tilt
speed is 24°/sec. The CM6700 controller with the KBD200 keyboard has programmable fixed speeds.
ELECTRICAL
Input Voltage:
18-30 VAC, 24 VAC nominal
Input Power
In-ceiling:
30 vA
30 vA
75 vA
Indoor pendant:
Outdoor pendant:
Fuse: 1.6 A
Relay Contacts
Type:
AUX 1
Form C
Low voltage (<40 V)
2 A maximum
AUX 2 Output
Open collector transistor output
32 VDC maximum
Voltage:
Current:
150 mA maximum
GENERAL
Environment
In-Ceiling:
Pendant:
Indoor only
Indoor/outdoor
Operating Range
In-Ceiling:
32° to 140°F (0° to 60°C) intermittent operation; 32° to 122°F (0° to 50°C) continuous operation
Pendant
Without Heater:
32° to 140°F (0° to 60°C) absolute maximum operating temperature; 32° to 122°F (0° to 50°C) sustained
maximum operating temperature
With Heater:
(Assumes no wind chill factor; for detailed test conditions, contact Pelco.)
Maximum operating temperature: 140°F (60°C) absolute maximum; 122°F (50°C) sustained maximum
Minimum operating temperature: -60°F (-51.11°C) absolute minimum; minimal icing at -50°F (-45.56°C)
sustained minimum; prevents icing at -40°F (-40°C) sustained minimum; de-ices .1 inch (2.5 mm) within 3
hours after power-up
Pelco Installation Manual C1487M-H (1/01)
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions:
Ratings:
See Figure 1
NEMA Type 1–In-ceiling back boxes, all dome drives
NEMA Type 4X–Pendant back boxes
IP 66–Pendant back boxes
Weight
Unit
Shipping
In-Ceiling
Back Box:
Dome Drive:
Lower Dome:
Pendant
2.6 lb (1.18 kg)
2.65 lb (1.20 kg)
.19 lb (.09 kg)
4 lb (1.81 kg)
5 lb (2.27 kg)
1 lb (.45 kg)
Back Box:
2.85 lb (1.28 kg)
5 lb (2.27 kg)
Add 1.25 lbs (.57 kg) for heater and sun shield
Dome Drive:
Lower Dome:
2.65 lb (1.20 kg)
1.30 lb (.59 kg)
5 lb (2.27 kg)
2.20 lb (1.0 kg)
Add .25 lbs (.11 kg) for heater
TOP PORTION OF BACK BOX
DOME IS SECURED
IS REMOVABLE FOR SURFACE TO CEILING BY
MOUNT APPLICATIONS
MOUNTING BRACKET
8.52
(21.64)
7.25 (18.13)
6.60 (16.76)
5.25
(13.34)
6.75
(17.15)
10.90
(27.69)
5.83
(14.80)
3.25
(8.26)
5.90 (14.99)
8.25 (20.96)
5.90
(14.99)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.
Figure 1. SD5 Series Dimension Drawing
20
Pelco Installation Manual C1487M-H (1/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
CAMERAS
COLOR (Spectra II and Spectra Lite)
Signal Format:
NTSC (Spectra II dome drive models DD5BC, DD5BC22, and DD5BCBW)
PAL (Spectra II dome drive models DD5BC-X, DD5BC22-X, and DD5BCBW-X)
NTSC (Spectra Lite dome drive model DD5TAC)
PAL (Spectra Lite dome drive model DD5TAC-X)
Scanning System:
Image Sensor:
2:1 interlace
1/4-inch interline transfer CCD
Effective Pixels
NTSC Spectra II:
PAL Spectra II:
768 (H) x 494 (V)
752 (H) x 582 (V)
510 (H) x 492 (V)
500 (H) x 582 (V)
NTSC Spectra Lite:
PAL Spectra Lite:
Horizontal Resolution
Spectra II:
>470 TV lines
470 TVL (NTSC)
460 TVL (PAL)
Spectra Lite:
Lens
Minimum f-stop
Spectra II
16X:
18X:
22X:
Spectra Lite:
F1.4
F1.4
F1.6
F1.6
Focal Length
Spectra II
16X:
4 mm to 64 mm optical
4.1 mm to 73.8 mm optical
4 mm to 88 mm optical
3.9 mm to 63 mm optical
18X:
22X:
Spectra Lite:
Zoom Ratio
Spectra II
16X:
16X optical zoom, 8X electronic zoom
18X optical zoom, 4X electronic zoom
22X optical zoom, 8X electronic zoom
16 optical zoom
18X:
22X:
Spectra Lite:
Digital Slow Shutter:
Auto/manual speed selection
Horizontal Angle of View
Spectra II
16X:
47° (at 4 mm wide zoom),
3° (at 64 mm telephoto zoom)
48° (at 4.1 mm wide zoom),
2.7° (at 73.8 mm telephoto zoom)
47° (at 4 mm wide zoom),
18X:
22X:
2° (at 88 mm telephoto zoom)
45° (at 3.9 mm wide zoom),
3° (at 63 mm telephoto zoom)
Spectra Lite:
MTBF
16X:
>2 million cycles at room temperature (zoom, focus, irs)
>500,000 cycles at room temperature (zoom, focus, irs)
>2 million cycles at room temperature (zoom, focus, irs)
>1 million cycles at room temperature (zoom, focus, irs)
18X:
22X:
Spectra Lite:
Focus:
Automatic and manual override
Pelco Installation Manual C1487M-H (1/01)
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Sensitivity
Spectra II
16X:
18X:
.05 lux at 1/2-second shutter speed
.2 lux at 1/4-second shutter speed (color)
.013 lux at 1/4-second shutter speed (black & white)
.07 lux at 1/1.5-second shutter speed
22X:
Spectra Lite:
1 lux at f1.6 at signal level of 40 IRE, gain high (AGC on)
Sync System:
White Balance:
AC line lock, phase adjustable via remote control*
Automatic with manual override*
Shutter Speed Models
DD5BC, DD5BC22,
and DD5AM:
1/2-1/30,000*
DD5BC-X, DD5BC22-X,
and DD5AM-X:
DD5BCBW:
DD5BCBW-X:
DD5TAC:
1/1.5 to 1/30,000*
1/4 to 1/10,000*
1/3 to 1/10,000*
1/60 to 1/10,000*
1/50 to 1/10,000*
DD5TAC-X:
Iris Control
Spectra II:
Spectra Lite:
Automatic with manual override*
Automatic with manual override*
Gain Control:
Automatic with manual override*
Video Output
NTSC:
.714V ± .07V (100 IRE ± 10 IRE)
PAL:
.7V ± .07V
Signal to Noise Ratio:
>46 dB
MONOCHROME (Spectra II Only)
Signal Format:
EIA (model DD5AM)
CCIR (model DD5AM-X)
Scanning System:
Image Sensor:
2:1 interlace
1/4-inch interline transfer CCD
Horizontal
Resolution:
>500 TV lines
Effective Pixels
EIA:
768 (H) x 494 (V)
752 (H) x 582 (V)
CCIR:
Lens
Minimum f-stop:
Focal Length:
Zoom Ratio:
Horizontal
F1.4
4 mm to 64 mm optical
16X optical zoom, 8X electronic zoom
Angle of View:
47° (at 4 mm wide zoom),
3° (at 64 mm telephoto zoom)
MTBF:
Focus:
>2 million cycles at room temperature (zoom, focus, iris)
Automatic with manual override
Sensitivity
EIA:
.1 lux at f1.4, AGC gain 26.5 dB, signal level 40 IRE, without IR cut filter
.1 lux at f1.4, AGC gain 29.5 dB, signal level 300 mV, without IR cut filter
CCIR:
Signal Process:
Sync System:
DSP-3R
AC line lock, phase adjustable via remote control*
22
Pelco Installation Manual C1487M-H (1/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
Shutter Speed:
EIA:
Automatic (electronic iris)/manual
1/60-1/30,000
CCIR:
1/50-1/30,000
Iris Control:
Automatic with manual override*
Automatic with manual override*
Gain Control:
Video Output
EIA:
.714V ± .07V (100 IRE ± 10 IRE)
CCIR:
.7V ± .07V
Signal to Noise Ratio:
>46 dB
* Manual control of camera setup functions can be done with CM6700, CM8500, CM9500, CM9760 and MPT9500 controllers, but not
with CM7500, MPT9000 or KBD9000 controllers.
(Design and product specifications subject to change without notice.)
CERTIFICATIONS AND REGULATORY NOTICES
CE, Class A (models DD5BC-X and DD5BC22-X).
CE, Class B (models BB5A-F, BB5A-PB, BB5A-PG, BB5A-PG-E, BB5T-F, BB5T-PB, BB5T-PG, BB5T-PG-E, DD5TAC-X, DD5AM-X,
and DD5BCBW-X). (Model BB5A-PSG-E, Pending)
UL/cUL (models BB5A-F, BB5A-PB, BB5A-PG, BB5A-PG-E, DD5AM, BB5T-F, BB5T-PB, BB5T-PG, BB5T-PG-E, DD5TAC, DD5BC,
DD5BC22, and DD5BCBW). (Model BB5A-PSG-E, Pending)
FCC Class A (model DD5BC22)
FCC Class B (models DD5AM, DD5BC, DD5TAC, and DD5BCBW).
Suitable for use in environmental air handling spaces (BB5A-F and BB5T-F).
FCC Class B meets more stringent requirements than FCC Class A.
The following applies to the DD5AM, DD5BC, and DD5TAC models.
FCC Class B - This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of the
FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However there is no guarantee that the interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
The following applies to the DD5BC22 model.
FCC Class A - This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the
FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own
expense.
Pelco Installation Manual C1487M-H (1/01)
23
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
If
a
warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following
information:
1. Model and serial number
Exceptions to this warranty are as noted below:
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
If there is a dispute regarding the warranty of a product which does not fall under the
warranty conditions stated above, please include a written explanation with the product
when returned.
Three years on Camclosure® and fixed camera models, except the CC3701H-2,
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,
which have a five-year warranty.
Method of return shipment shall be the same or equal to the method by which the item was
received by Pelco.
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
fixed dome products.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned
for credit, and RA number if returned for repair).
•
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
•
•
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing
charge.
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura™ Series distributed network-based video products.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA
number and freight should be prepaid. Ship to the appropriate address below.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Six months on all pan and tilts, scanners or preset lenses used in continuous motion
applications (that is, preset scan, tour and auto scan modes).
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are
instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from
the specific use or application made of the Products. Pelco’s liability for any claim, whether
based on breach of contract, negligence, infringement of any rights of any party or product
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for
such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused,
whether by the negligence of Pelco or otherwise.
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
REVISION HISTORY
Manual # Date Comments
C1487M
7/98
Original version.
C1487M-A 11/98 Revised the manual to incorporate Spectra Lite material. Added material on CCIR and EIA monochrome cameras, and PAL
color camera. Revised material in Section 5.11.21.2, Programming Limit Stops. Revised Section 6.0, Troubleshooting. Changed
the fixed-speed controller rate in Section 8.0, Specifications.
C1487M-B 2/99
Changed Spectra Lite model numbers, and added comments that the line sync feature is not functional for the DD5T-C model
of Spectra Lite. Changed power specifications for indoor models from 25 vA to 30 vA and for outdoor models from 90 vA to
75 vA. Revised maximum temperature operating ranges. Revised color camera specifications.
Changed auto iris material to include Spectra Lite as well as Spectra II.
3/99
C1487M-C 7/99
Added a note relating to running patterns when an alarm activates. Changed the preset tilt speed from 100 to 200 degrees/
second. Added model number and specifications for Spectra Lite PAL camera. Revised manual to new format.
C1487M-D 7/99
C1487M-E 9/99
Changed Spectra Lite camera zoom from 12X to 16X. Changed line sync and auto focus material to include Spectra Lite as
well as Spectra II. Removed auto iris peak and auto sharpness options for Spectra Lite. Added white balance hue option for
Spectra Lite and removed R-B and M-G white balance options for Spectra Lite. Revised Spectra Lite camera specifications.
Replaced the standard Spectra II DD5AC and DD5AC-X cameras with model DD5BC and DD5BC-X LowLight color cam-
eras. Added optional 176X color models. Revised main menu access documentation to include the KBD4000/KBD4002/
KBD4000V keyboards. Added material on LowLight limit. Revised material on shutter speed and zoom. Added material on
zone overlap and priorities. Revised color camera specifications.
C1487M-F 3/00
C1487M-G 5/00
C1487M-H 1/01
Separated into two manuals - Installation Manual and Operation and Programming Manual.
Added information on Spectra II Color/Black and White.
Added step to dome drive installation instructions referencing the new RS-422 termination switch. Revised specifications
and certifications.
® Pelco, the Pelco logo, Spectra, Genex, Legacy, and Coaxitron are registered trademarks of Pelco.
™ Spectra II, Spectra Lite, Esprit, and Camclosure are trademarks of Pelco.
® Loctite is a registered trademark of Loctite Corporation.
© Copyright 2001, Pelco. All rights reserved.
U.S. Patent No. 5,931,432.
Download from Www.Somanuals.com. All Manuals Search And Download.
|