I N S T A L L A T I O N  
Heavy-Duty  
Spectra® IV Series  
In-Ceiling Back Box  
C3419M (8/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Locate the center point of the mounting location and insert the compass tool. Draw a circle.  
2. Cut the circle out of the ceiling.  
3. Use the mounting ring as a template and mark the screw hole pattern onto the mounting surface. Prepare the holes.  
4. Install the mounting plates. Use the eight 10-32 x 3-inch screws (supplied) and install the mounting ring and two  
back mounting plates .  
a. Line up the mounting ring with the eight fastener holes.  
b. Feed one back mounting plate through the hole in the ceiling and line up with four fastener holes.  
c. Install fasteners through the mounting ring , ceiling, and out the back mounting plate .  
d. Install second back mounting plate .  
5. Attach the conduit fitting, lock nut, and safety chain bracket. Install a safety chain/cable (not supplied) that will  
support up to 16 pounds (7.3 kg).  
6. Open the hinged door to the back box. Push the tab lock towards the wall of the unit and lift the door open.  
Pull wiring into the back box through the conduit fitting. Refer to Table A, Table B, and Table C for wiring distances.  
Table A. Video Coaxial Cable  
Table B. 24 VAC/24VDC Wiring Distances  
Requirements  
The following are the recommended maximum distances for 24 VAC  
and 24 VDC applications and are calculated with a 10 percent voltage  
drop. (Ten percent is generally the maximum allowable voltage drop  
for AC- or DC-powered devices.)  
Cable Type* Maximum Distance  
RG59/U  
RG6/U  
750 ft (229 m)  
1,000 ft (305 m)  
1,500 ft (457 m)  
Wire Gauge  
18 AWG 16 AWG  
(0.5 mm2) (1.0 mm2) (1.5 mm2) (2.5 mm2)  
AC/DC  
Total VA/  
Total Watts  
RG11/U  
20 AWG  
14 AWG  
*Cable requirements:  
75 ohms impedance  
All-copper center conductor  
All-copper braided shield with 95% braid  
coverage  
23 VA/  
15 watts  
123 ft  
(38 m)  
196 ft  
(60 m)  
311 ft  
(95 m)  
495 ft  
(151 m)  
NOTE: Input power for the dome is 24 VAC or 24 VDC. Using 24 VAC input power, power consumption is 23 VA per dome.  
Using 24 VDC input power, power consumption is 0.7 A (15 watts). Use a 24 VAC transformer with a minimum of 40 VA per  
dome.  
.
Table C. UTP Wiring Distances  
Receiver  
Maximum Distance  
Active  
0-3,000 ft  
(Video Only)  
(0-914.4 m)  
Passive  
0-750 ft  
(Video, Coaxitron, Pelco V-Sync)  
(0-228.6 m)  
NOTE: As a minimum, UTP requires Cat5, 100-ohm twisted pair cable.  
C3419M (8/06)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7
8
1
2
3
4
5
6
7
ALARMS  
AUX1  
GND  
NO  
COM  
NC  
AUX2  
GND  
VIDEO  
PWR- GND PWR+ RX- RX- TX- TX- UTP+ UTP-  
4
C3419M (8/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Install the back box by compressing the spring clips and pushing the back box through the hole. Tighten the screws  
until you hear a clicking noise.  
WARNING: An electrical short in the back box may occur if the metal BNC connector is not completely covered by  
the protective boot.  
8. Connect wiring to the circuit board inside the back box. When finished, close the door to the back box and turn on the  
power. The green LED will light.  
NOTES:  
Aux 1: Maximum 2 A at low voltage (<40 V)  
Aux 2: Maximum 30 mA at 32 VDC  
If you are using both unshielded twisted pair (UTP) wiring and a translator board, install the UTP wiring before  
installing the translator board.  
C3419M (8/06)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
SWITCH 1 AND 2  
11  
9
BALL STUD  
TRIM LEASH  
BALL STUD  
RECEIVER  
BARREL  
KEY LOCK  
10  
6
C3419M (8/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. Configure DIP switches SW1 and SW2 located on the top of the dome drive. For DIP switch settings, refer to the  
labels located on the top of the dome drive or to the Switch Settings section of this manual.  
NOTE: When connecting more than one Spectra dome to a single controller, terminate the unit farthest from the  
controller. To terminate the dome drive set the SW2-10 switch to the ON position.  
10. Install the dome drive. Line up the blue and red tabs with the blue and red arrows on the hinged door inside the back  
box. Push in on the tabs. Insert one side and then the other side. Continue pushing on the ends of the tabs until both  
sides click into place.  
11. Install the lower dome. Snap the clip of the lower trim ring leash into the hole on the lip of the back box. Insert  
both keys in the barrel locks . Turn keys clockwise to the unlocked position. Keys cannot be removed from lock in  
the unlocked position. Align ball studs (located on the mount ring) with the ball stud receptacles (located on  
the inside of the lower dome). Place the lower dome over the back box. Hold and turn both keys to the locked  
position.  
To use your dome, refer to the operation and programming manual.  
Troubleshooting  
If your dome does not power up properly after installation, use the following steps.  
1. Check the fuse on the circuit board inside the back box for continuity. Replace the fuse if needed.  
2. Check the wiring with a volt meter to ensure proper voltage is being received into the back box.  
If your dome powers up correctly, but you do not have accurate control, use the following steps.  
1. Check the signal with a volt meter or an oscilloscope.  
NOTE: This step will not apply if you are using Coaxitron control.  
2. Ensure that the switch settings on the dome drive are set correctly. Refer to the Switch Settings section.  
3. If you are using a Pelco controller, ensure that the factory-installed 16-pin jumper has not been removed. If you are  
using a third-party controller, a TXB Series translator board must be installed. The dome will not function without this  
16-pin jumper or a translator board installed.  
C3419M (8/06)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Switch Settings  
WARNING: If you are using D-type or P-type control, your system may not operate if the baud rate and address  
switches are not set correctly. The switches are set at the factory at the defaults for D-type control (2400 baud and  
address 1).  
Table D. Switch Settings for SW2  
Special Systems  
Switch Number  
1
2
3
4
5
6
7
8
9
10  
AD-32 Preset System  
CM9502 Setting  
ON  
ON  
Not currently available; SW2-3 is reserved for future use.  
Vicon  
D or P Protocol Baud Rate  
Switch Number  
1
2
3
4
5
6
7
8
9
10  
2400 Baud (Default for D-type Control)  
4800 Baud (Default for P-type Control)  
9600 Baud  
OFF OFF OFF  
ON  
OFF OFF  
ON OFF  
OFF  
Video Cable Type  
Switch Number  
Coax Cable  
1
2
3
4
5
6
7
8
9
10  
OFF  
ON  
UTP Cable  
Dome Termination  
Switch Number  
Terminated  
1
2
3
4
5
6
7
8
9
10  
ON  
OFF  
Not Terminated  
8
C3419M (8/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table E. Switch Settings for SW1, P-Type Control  
NOTE: For Coaxitron controls, SW1 is not used; set all switches OFF. For D-type control systems, refer to Table F.  
SWITCH SETTING  
SWITCH SETTING  
SPECTRA  
ADDRESS  
SPECTRA  
ADDRESS  
SW1-1  
OFF  
ON  
SW1-2  
SW1-3  
OFF  
OFF  
OFF  
OFF  
ON  
SW1-4  
SW1-5  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
SW1-1  
OFF  
ON  
SW1-2  
SW1-3  
OFF  
OFF  
OFF  
OFF  
ON  
SW1-4  
SW1-5  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
1
2
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
3
OFF  
ON  
OFF  
ON  
4
5
OFF  
ON  
OFF  
ON  
6
ON  
ON  
7
OFF  
ON  
ON  
OFF  
ON  
ON  
8
ON  
ON  
9
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
10  
11  
12  
13  
14  
15  
16  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
ON  
ON  
OFF  
ON  
ON  
OFF  
ON  
ON  
ON  
ON  
Table F. Switch Settings for SW1, D-Type Control  
NOTE: For Coaxitron controls, SW1 is not used; set all switches OFF. For P-type control systems, refer to Table E.  
SWITCH SETTING  
SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
SWITCH SETTING  
SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
SPECTRA  
ADDRESS  
SPECTRA  
ADDRESS  
1
2
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
C3419M (8/06)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SWITCH SETTING  
SWITCH SETTING  
SPECTRA  
ADDRESS  
SPECTRA  
ADDRESS  
SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
71  
72  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
73  
74  
75  
76  
77  
78  
79  
80  
ON  
81  
ON  
ON  
82  
ON  
ON  
83  
ON  
ON  
84  
ON  
ON  
85  
ON  
ON  
86  
ON  
ON  
87  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
88  
ON  
ON  
89  
ON  
ON  
90  
ON  
ON  
91  
ON  
ON  
92  
ON  
ON  
93  
ON  
ON  
94  
ON  
ON  
95  
ON  
ON  
96  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
97  
ON  
ON  
ON  
98  
ON  
ON  
ON  
99  
ON  
ON  
ON  
100  
101  
102  
103  
104  
105  
106  
107  
108  
109  
110  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
10  
C3419M (8/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SWITCH SETTING  
SWITCH SETTING  
SPECTRA  
ADDRESS  
SPECTRA  
ADDRESS  
SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
111  
112  
113  
114  
115  
116  
117  
118  
119  
120  
121  
122  
123  
124  
125  
126  
127  
128  
129  
130  
131  
132  
133  
134  
135  
136  
137  
138  
139  
140  
141  
142  
143  
144  
145  
146  
147  
148  
149  
150  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
151  
152  
153  
154  
155  
156  
157  
158  
159  
160  
161  
162  
163  
164  
165  
166  
167  
168  
169  
170  
171  
172  
173  
174  
175  
176  
177  
178  
179  
180  
181  
182  
183  
184  
185  
186  
187  
188  
189  
190  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
C3419M (8/06)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SWITCH SETTING  
SWITCH SETTING  
SPECTRA  
ADDRESS  
SPECTRA  
ADDRESS  
SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8  
191  
192  
193  
194  
195  
196  
197  
198  
199  
200  
201  
202  
203  
204  
205  
206  
207  
208  
209  
210  
211  
212  
213  
214  
215  
216  
217  
218  
219  
220  
221  
222  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
223  
224  
225  
226  
227  
228  
229  
230  
231  
232  
233  
234  
235  
236  
237  
238  
239  
240  
241  
242  
243  
244  
245  
246  
247  
248  
249  
250  
251  
252  
253  
254  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
12  
C3419M (8/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
GENERAL  
ELECTRICAL (Dome Drive Only)  
Construction  
Input Voltage  
18-32 VAC; 24 VAC nominal  
Back Box  
Aluminum  
22-27 VDC; 24 VDC nominal  
Dome Drive  
Lower Dome  
Aluminum, thermoplastic  
Clear polycarbonate, 0.090-inch  
thick  
0.12 x 0.30-inch cast stainless  
steel  
Input Power  
24 VAC  
24 VDC  
23 VA nominal (indoor, without heater)  
0.7 A nominal (indoor, without heater)  
Cage Thickness  
Fuse  
1.25 A  
Cage Color  
Black, for maximum discreetness  
Auxiliary Outputs  
Alarm Inputs  
2 (Spectra IV SE only)  
7 (Spectra IV SE only)  
Cable Entry (Back Box)  
Pan Movement  
Vertical Tilt  
0.75-inch conduit fitting  
360° continuous pan rotation  
+2° to -92°  
Manual Pan/Tilt Speeds*  
Pan  
0.1°- 80°/sec manual operation,  
150°/sec turbo  
Tilt  
0.1°- 40°/sec  
5.25  
(13.34)  
8.5  
(21.59)  
Preset Speeds  
Pan  
Tilt  
400°/sec  
200°/sec  
Environment  
Indoor only  
Operating Temperature  
32° to 122°F (0° to 50°C)  
Weight (approximate)  
Back Box  
Dome Drive  
Lower Dome  
In-Ceiling  
Ø6.13  
(Ø15.57)  
9.75  
(24.77)  
2.17 lb (0.98 kg)  
3.3 lb (1.48 kg)  
0.2 lb (0.09 kg)  
1.6 lb (0.73 kg)  
3.6 lb (1.63 kg)  
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS;  
ALL OTHERS ARE INCHES.  
In-Ceiling with Cage  
*For variable-speed operation an appropriate controller is required. With fixed-speed controllers, pan/tilt speed is 20°/sec.  
The CM6700/CM6800 controller with the KBD200A keyboard has programmable fixed speeds.  
C3419M (8/06)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC  
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the  
European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures  
for recycling this equipment.  
14  
C3419M (8/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective  
in material or workmanship for a period of one year after the date of  
shipment.  
If  
a
warranty repair is required, the Dealer must contact Pelco at  
(800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number  
(RA), and provide the following information:  
Exceptions to this warranty are as noted below:  
1. Model and serial number  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
Five years on FR/FT/FS Series fiber optic products and TW3000 Series  
unshielded twisted pair transmission products.  
Three years on Spectra® IV products.  
If there is a dispute regarding the warranty of a product which does not fall  
under the warranty conditions stated above, please include a written explana-  
tion with the product when returned.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
Three years on Camclosure® and fixed camera models, except the  
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and  
MC3651H-2X camera models, which have a five-year warranty.  
Method of return shipment shall be the same or equal to the method by which  
the item was received by Pelco.  
Three years on PMCL200/300/400 Series LCD monitors.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/  
DF8 Series fixed dome products.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call  
the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization num-  
ber (CA number if returned for credit, and RA number if returned for repair).  
Two years on Spectra III, Esprit®, ExSite, and PS20 scanners, including  
when used in continuous motion applications.  
Two years on Esprit and WW5700 Series window wiper (excluding wiper  
blades).  
Two years (except lamp and color wheel) on Digital Light Processing (DLP®  
All merchandise returned for credit may be subject to a 20% restocking and  
refurbishing charge.  
)
displays. The lamp and color wheel will be covered for a period of 90 days.  
The air filter is not covered under warranty.  
Goods returned for repair or credit should be clearly identified with the assigned  
CA or RA number and freight should be prepaid. Ship to the appropriate address  
below.  
Eighteen months on DX Series digital video recorders, NVR300 Series  
network video recorders, and EnduraSeries distributed network-based  
video products.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico,  
send goods to:  
One year (except video heads) on video cassette recorders (VCRs). Video  
heads will be covered for a period of six months.  
Service Department  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
Six months on all pan and tilts, scanners or preset lenses used in continu-  
ous motion applications (that is, preset scan, tour and auto scan modes).  
Pelco will warrant all replacement parts and repairs for 90 days from the date  
of Pelco shipment. All goods requiring warranty repair shall be sent freight  
prepaid to Pelco, Clovis, California. Repairs made necessary by reason of mis-  
use, alteration, normal wear, or accident are not covered under this warranty.  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico  
and are instructed to return goods to the USA, you may do one of the following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
Pelco assumes no risk and shall be subject to no liability for damages or loss  
resulting from the specific use or application made of the Products. Pelco’s  
liability for any claim, whether based on breach of contract, negligence,  
infringement of any rights of any party or product liability, relating to the  
Products shall not exceed the price paid by the Dealer to Pelco for such  
Products. In no event will Pelco be liable for any special, incidental or conse-  
quential damages (including loss of use, loss of profit and claims of third  
parties) however caused, whether by the negligence of Pelco or otherwise.  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
Pelco c/o Expeditors  
473 Eccles Avenue  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
The above warranty provides the Dealer with specific legal rights. The Dealer  
may also have additional rights, which are subject to variation from state to  
state.  
REVISION HISTORY  
Manual #  
Date  
Comments  
C3419M  
8/06  
Original version.  
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.  
Endura, ExSite, and Spectra III are trademarks of Pelco.  
©Copyright 2006, Pelco. All rights reserved.  
DLP is a registered trademark of Texas Instruments, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Worldwide Headquarters  
3500 Pelco Way  
Clovis, California 93612 USA  
USA & Canada  
Tel: 800/289-9100  
Fax: 800/289-9150  
International  
Tel: 1-559/292-1981  
Fax: 1-559/348-1120  
ISO9001  
Australia Canada Finland France Italy Russia Singapore Spain Sweden The Netherlands United Arab Emirates United Kingdom United States  
|
|
|
|
|
|
|
|
|
|
|
|
Download from Www.Somanuals.com. All Manuals Search And Download.  

Pentax Camera Lens INTERCHANGEABLE LENS User Manual
Philips Clock Radio AJ3551 User Manual
Philips Electric Shaver QG3150 User Manual
Philips Network Router SWR1221 User Manual
Philips Pressure Washer 200WB7 User Manual
Philips TV Antenna SDV1225T 27 User Manual
Planar Computer Monitor PT150M User Manual
Poulan Trimmer 545123431 User Manual
Pride Mobility Mobility Aid INFINFB2042 User Manual
ProForm Treadmill 8312916 User Manual