USER
MANUAL
MODEL 2707/I
G.703 NTU with 10Base-T
Ethernet Interface
Part# 07M2707/I-A
Doc# 086251UA
Revised 10/2/01
SALES OFFICE
(301) 975-1000
TECHNICAL SUPPORT
(301) 975-1007
An ISO-9001
Download from Www.Somanuals.com. All Manuals Search And Download.
B.9 Diagnostics ......................................................................21
B.10Indicators ........................................................................21
B.11Configuration ..................................................................21
B.12Power Supply ..................................................................22
B.13Humidity ...........................................................................22
B.14Temperature ...................................................................22
B.15Dimensions ......................................................................22
C
Factory Replacement Parts and Accessories......................... 23
3
Download from Www.Somanuals.com. All Manuals Search And Download.
1.0 WARRANTY INFORMATION
Patton Electronics warrants all Model 2707/I components to be free
from defects, and will—at our option—repair or replace the product
should it fail within one year from the first date of shipment.
This warranty is limited to defects in workmanship or materials, and does
not cover customer damage, abuse, or unauthorized modification. If this
product fails or does not perform as warranted, your sole recourse shall
be repair or replacement as described above. Under no condition shall
Patton Electronics be liable for any damages incurred by the use of this
product.These damages include, but are not limited to, the following: lost
profits, lost savings and incidental or consequential damages arising
from the use of or inability to use this product. Patton Electronics spe-
cifically disclaims all other warranties, expressed or implied, and the
installation or use of this product shall be deemed an acceptance of
these terms by the user.
1.1 RADIO AND TV INTERFERENCE
The Model 2707/I generates and uses radio frequency energy, and if not
installed and used properly—that is, in strict accordance with the manu-
facturer's instructions—may cause interference to radio and television
reception. The Model 2707/I has been tested and found to comply with
the limits for a Class A computing device in accordance with the specifi-
cations in Subpart B of Part 15 of FCC rules, which are designed to pro-
vide reasonable protection from such interference in a commercial
installation. However, there is no guarantee that interference will not
occur in a particular installation. If the Model 2707/I does cause interfer-
ence to radio or television reception, which can be determined by discon-
necting the cables, the user is encouraged to try to correct the
interference by one or more of the following measures: moving the com-
puting equipment away from the receiver, re-orienting the receiving
antenna, and/or plugging the receiving equipment into a different AC out-
let (such that the computing equipment and receiver are on different
branches).
1.2 CE NOTICE
The CE symbol on your Patton Electronics equipment indicates that it is
in compliance with the Electromagnetic Compatibility (EMC) directive
and the Low Voltage Directive (LVD) of the Union European (EU). A Cer-
tificate of Compliance is available by contacting Technical Support.
1.3 SERVICE
All warranty and nonwarranty repairs must be returned freight prepaid
and insured to Patton Electronics. All returns must have a Return Materi-
4
Download from Www.Somanuals.com. All Manuals Search And Download.
als Authorization number on the outside of the shipping container. This
number may be obtained from Patton Electronics Technical Services at:
• Tel: +1 (301) 975-1007
Note Packages received without an RMA number will not be
accepted.
This device is not intended to be connected to the public
telephone network.
Caution
5
Download from Www.Somanuals.com. All Manuals Search And Download.
2.0 GENERAL INFORMATION
Thank you for your purchase of this Patton Electronics product. This
product has been thoroughly inspected and tested and is warranted for
One Year parts and labor. If any questions or problems arise during
installation or use of this product, please do not hesitate to contact Pat-
ton Electronics Technical Support at (301) 975-1007.
2.1 FEATURES
• Terminates G.703 E1 service
• Available in low-cost standalone or rack-mountable versions
•
2.048 Mbps data rate
• 10Base-T Ethernet bridge
• PPP (Point to Point Protocol, RFC 1661) with Bridge Control Protocol
(RFC 1638)
• 75-ohm dual coax and 120-ohm twisted-pair G.703 connections
• Line loopback diagnostics
• Internal and G.703 network timing
• CE marked
• 100–240 VAC & 48 VDC power options
• Conforms to ONP requirement CTR 12 for connection to international
Telecom networks
2.2 DESCRIPTION
The Model 2707/I receives clear channel E1/G.703 (2.048-Mbps) data
from the telco's digital data network. The Model 2707/I terminates the
G.703 telco interface and converts the data for transmission to a user-
oriented 10Base-T (802.3) Ethernet interface.
The Ethernet (Model 2707/I) supports an integrated 10Base-T (802.3)
Ethernet port with transparent bridging capability for IP, IPX, DECnet,
NetBIOS and other layer-3 protocols. The 2707/I attaches to the LAN
and intelligently bridges data traffic to the large central site router
through the telco's leased line network. The 2707/I supports PPP (RFC
1661) and BCP (RFC 1638).
The Model 2707/I is a 10Base-T bridge that operates over G.703 lines. It
uses MAC learning and forwarding to provide seamless LAN-to-LAN
connectivity. As a result, corporate enterprises can connect their servers
to a pair of NTUs and automatically forward data packets that are meant
for the remote network. Local packets are filtered and passed only to the
local LAN.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
3.0 PPP OPERATIONAL BACKGROUND
PPP is a protocol used for multi-plexed transport over a point-to-point
link. PPP operates on all full duplex media, and is a symmetric peer-to-
peer protocol, which can be divided into the following main components:
• A standard method to encapsulate datagrams over serial links
• A Link Control Protocol (LCP) to establish, configure, and test the
data-link connection
• A family of Network Control Protocols (NCPs) to establish and config-
ure different network layer protocols
In order to establish communications over a point-to-point link, each end
of the PPP link must first announce its capabilities and agree on the
parameters of the link’s operation. This exchange is facilitated through
LCP Configure-Request packets.
Once the link has been established and optional facilities have been
negotiated, PPP will attempt to establish a network protocol. PPP will
use Network Control Protocol (NCP) to choose and configure one or
more network layer protocols. Once each of the network layer protocols
have been configured, datagrams from the established network layer
protocol can be sent over the link. The link will remain configured for
these communications until explicit LCP or NCP packets close the link
down, or until some external event occurs.
The PPP Bridging Control Protocol (BCP), defined in RFC 1638, config-
ures and enables/disables the bridge protocol on both ends of the point-
to-point link. BCP uses the same packet exchange mechanism as the
Link Control Protocol (LCP). BCP is a Network Control Protocol of PPP,
bridge packets may not be exchanged until PPP has reached the net-
work layer protocol phase.
3.1 APPLICATIONS
In situations where a routed network requires connectivity to a remote
Ethernet network, the interface on a router can be configured as a PPP
IP Half Bridge. The WAN line to the remote bridge functions as a Virtual
Ethernet interface, effectively extending the routers WAN port connection
to the remote network.The bridge device sends bridge packets (BPDU’s)
to the router’s WAN interface. The router will receive the layer three
address information and will forward these packets based on its IP
address.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Model 2707/I
Model 2707/C
Router
E1
Internet
Ethernet
LAN
Customer’s Site
Service Provider’s Network
Figure 1. Cisco router with serial interface, configured as PPP Half Bridge.
Figure 1 shows a typical Cisco router with a serial interface configured
as a PPP Half Bridge. The router serial interface connects to the WAN
via a 2707/C (V.35) E1 NTU and to the remote 2707/I with support for
PPP bridging. The 2707/I functions as a node on the remote Ethernet
network. The serial interface on the Cisco will have an IP address on the
same Ethernet subnet as the bridge.
For example, the customer site is assigned the addresses 192.168.1.0/
24 through 192.168.1.1/24. The address 192.168.1.1/24 is also the
default gateway for the remote network. The above settings remove any
routing/forwarding intelligence from the 2707/I. The associated Cisco
configuration will set serial interface (s0) to accommodate half bridging
for the above example.
!
interface s0
ppp bridge ip
ip address 192.168.1.1 255.255.255.0
!
Authentication is optional under PPP. In a point-to-point leased-line link,
incoming customer facilities are usually fixed in nature, therefore authen-
tication is generally not required.
Some networking systems do not define network numbers in packets
sent out over a network. If a packet does not have a specific destination
network number, a router will assume that the packet is set up for the
local segment and will not forward it to any other sub-network. However,
in cases where two devices need to communicate over the wide-area,
bridging can be used to transport non-routable protocols.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
4.0 CONFIGURATION
The Model 2707/I features configuration capability via hardware DIP
switches.This section describes all possible DIP switch configurations of
the Model 2707/I.
4.1 DIP SWITCH CONFIGURATIONS
The Model 2707/I has an internal DIP switch that enables configuration
for a wide range of applications. The DIP switch is accessed from the
underside. Figure 2 shows the location of the DIP switches on the bottom
of the printed circuit board.
Front
S1
Rear
Figure 2. Underside of Model 2707/I, showing location of DIP switches
The DIP switches can be configured as either “ON” or “OFF”. Figure 3
shows the orientation of the DIP switches with respect to ON/OFF posi-
tions.
ON
ON
1
2
3
4
5
6
7
8
OFF
OFF
Figure 3. Close-up view of configuration switches
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Switch S1 settings
Table 1 shows the settings for DIP switch S1-1 thru S1-8.
Table 1: Switch S1 settings
Switch
Description
Line Coding
Setting
S1-1
Off = HDB3
On = AMI
S1-2
Line Loopback (toward
E1 line)
Off = LLB disabled
On = LLB enabled
Note The Model 2707/I, when
in line loopback mode,
will loop the network line
and return any trafic
received on the E1 line
to the sending device at
the remote end.
S1-3
S1-4
S1-5
Reserved
Reserved
Reserved
Off = Default
Off = Default
Off = Default
S1-6/S1-7 Clocking
Switch
1-6
Switch
1-7
On
On
Off
Off
On
Off
On
Off
Network
Internal (default)
Reserved
Network
S1-8
Reserved
Off = Default
SW1-1 Line Coding: HDB3 (default)
Use Switch SW1-1 to control the Network Line Coding options. Set these
options to be the same as the Line Coding given to you by your Service
Provider. If you are using two Model 2707/Is together as short range
modems, set both units to HDB3.
SW1-1 Line Encoding
Off
On
HDB3
AMI
Options: HDB3, AMI
• HDB3. In this line coding, the transmitter substitutes a deliberate bipo-
lar violation when excessive zeros in the data stream are detected.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
The receiver recognizes these special violations and decodes them as
zeros. This method enables the network to meet minimum pulse den-
sity requirements. Unless AMI is required in your application, HDB3
should be used whenever possible.
• AMI. Alternate Mark Inversion defines a pulse as a "mark,” a binary
one, as opposed to a zero. In an E1 network connection, signals are
transmitted as a sequence of ones and zeros. Ones are sent as
pulses, and zeros are sent as spaces, i.e., no pulse. Every other pulse
is inverted from the previous pulse in polarity, so that the signal can be
effectively transmitted. This means, however, that a long sequence of
zeros in the data stream will cause problems, since the NTU receiving
the signal relies on the signal to recover the 2.048 Mbps clock.
Note If you must use AMI, you should ensure that the data terminal
equipment connected to the unit provides a minimally accept-
able pulse density. For this reason, there are advantages to
using HDB3 instead. AMI coding does not inherently account for
ones density. To meet this requirement, the user should ensure
that the data inherently meets pulse density requirements.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
5.0 INSTALLATION
Once the Model 2707/I is properly configured, it is ready to connect to
the G.703 interface, to the Ethernet port, and to the power source. This
section describes how to make these connections.
This section describes installing the G.703 (75-ohm and 120-ohm),
Ethernet LAN, and power connections (shown in Figure 4). Refer to the
following to detemine which installation procedures you will use:
necting to a 75-ohm dual coax G.703 network interface. If your G.703
network terminates via dual coaxial cables, refer to section “Connect-
ing Dual Coaxial Cable (75 ohm) to the G.703 Network” on page 13
twisted-pair G.703 network interface. If your G.703 network terminates
with a RJ-48C, refer to section “Connecting the Twisted Pair (120 ohm)
to the G.703 Network” on page 14.
• The Ethernet 10Base-T port is configured as DTE (Data Terminal
Equipment). If the Model 2707/I is to connect to another DTE device
such as a 10Base-T network interface card in a PC, refer to “Connect-
ing the 10Base-T Ethernet port to a PC (DTE)” on page 14. Otherwise,
refer to “Connecting the 10Base-T Ethernet Port to a Hub” on page 15.
• Refer to “Power Connection” on page 15 to connect the Model 2707/I
to a 100–240 VAC source or to a 36–60 VDC DC-to-DC adapter.
120 ohm
Power Ethernet
75 ohm
75 ohm
TX
RX
Figure 4. Model 2707/I rear panel
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting Dual Coaxial Cable (75 ohm) to the G.703 Network
Refer to Figure 5 to make the proper connections.
TX
RX
Data
DataTO
FROM
Network
Network
Figure 5. Rear panel, showing location of connectors
Note The outer conductor of the coax cables are isolated from system
earth ground.
When using the 75-ohm interface, jumper straps JP2, JP5, JP6, and JP7
must be installed over the jumpers. The jumpers are located next to the
BNC connectors. Do the following to configure the jumpers:
1. Open the case by inserting a screwdriver into the slots and twist the
screwdriver head slightly. The top half of the case will separate from
the lower half of the case.Take caution not to damage any of the PC
board mounted components
2. Open the case and install jumper straps for JP2, JP5, JP6, and JP7.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting the Twisted Pair (120 ohm) to the G.703 Network
Refer to the pinout and signals chart in Figure 6 to connect the 120-ohm
G.703 network channel.
RJ-45 Cable (8-Wire)
G.703
NETWORK SIGNAL
2707/I
SIGNAL PIN#
RX+
RX-
TX+
TX-
5
4
TX+
TX-
RX+
RX-
1
2
Shield
Shield
Shield
Shield
3
6
(No Connection) 8
(No Connection) 7
(No Connection) 6
(TX+) 5
(TX-) 4
(No Connection) 3
(RX-) 2
8
7
6
5
4
3
2
1
(RX+) 1
Figure 6. G.703 120-ohm connection.
Connecting the 10Base-T Ethernet port to a PC (DTE)
To connect the Model 2707/I to another DTE device such as a 10Base-T
network interface card, construct a 10Base-T crossover cable and con-
nect the wires as shown in Figure 7 below and Figure 8 on page 15.
1 TD+ (data output from 2707/I)
2 TD- (data output from 2707/I)
3 RD+ (data input to 2707/I)
4 (no connection)
5 (no connection)
6 RD- (data input to 2707/I)
7 (no connection)
1
2
3
4
5
6
7
8
8 (no connection)
Figure 7. Connecting the 10Base-T Ethernet Port to a PC
14
Download from Www.Somanuals.com. All Manuals Search And Download.
10Base-T Port
RJ-45 Pin No.
10Base-T DTE
RJ-45 Pin No.
1 (TD+)
2 (TD-)
1 (TD+)
2 (TD-)
3 (RD+)
6 (RD-)
3 (RD+)
6 (RD-)
Figure 8. 10Base-T cross-over cable connection
Connecting the 10Base-T Ethernet Port to a Hub
The 10Base-T interface is configured as DTE (data terminal equipment),
just like a 10Base-T network interface card in a PC. Therefore, it
“expects” to connect to a 10Base-T Hub using a straight-through RJ-45
cable. Refer to Figure 9 below and Figure 7 on page 14 to construct a
cable to connect the 10 Base-T interface to a 10Base-T hub.
10Base-T Port
RJ-45 Pin No.
10Base-T Hub
RJ-45 Pin No.
1 (TD+)
2 (TD-)
1 (RD+)
2 (RD-)
3 (RD+)
6 (RD-)
3 (TD+)
6 (TD-)
Figure 9. Connecting the 10Base-T Ethernet port to a hub
Power Connection
Universal AC Power (100—240 VAC).The Model 2707/I uses a 5VDC,
2A universal input 100-240VAC, power supply (center pin is +5V). The
universal input power supply has a male IEC-320 power entry connector.
This power supply connects to the Model 2707/I by means of a barrel
jack on the rear panel. Many international power cords are available for
the universal power supply.
Note The Model 2707/I powers up as soon as it is plugged into an AC
outlet—there is no power switch.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
DC Power. The 36–60 VDC DC-to-DC adapter supplied with the DC ver-
sion of the Model 2707/I plugs in a DC source (nominal 48 VDC) and
plugs into the barrel power supply jack on the rear of the 2707/I. Refer to
Figure 10 to make the proper connection.
To power
supply jack
To -48 VDC
source
+Vin
-Vin
Figure 10. Connecting DC power to the 2707/I DC power supply
16
Download from Www.Somanuals.com. All Manuals Search And Download.
6.0 OPERATION
When the Model 2707/I has been properly configured and installed, it
should operate transparently. This section describes power-up, LED sta-
tus monitors, and the built-in loopback test modes.
6.1 POWER-UP
Before applying power to the Model 2707/I, please review section “Power
Connection” on page 15 to verify that the unit is properly connected to
the appropriate power source.
6.2 LED STATUS MONITORS
The Model 2707/I features six front panel LEDs that monitor connections
on the G.703 and 10Base-T links, signaling, error and test modes.
Figure 11 shows the front panel location of each LED. Table 2 on
page 18 lists descriptions of each LED.
10Base-T
Figure 11. 2707/I front panel
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 2: LED descriptions
LED
Description
E1 Link
(Active Green) Solid green (On) indicates that the end to
end E1 Link is up, signifying that the link is active.The E1
Link LED is Off when the link is down.
10BT Link (Active Green) Solid green indicates that the 10Base-T
Ethernet interface has detected a valid SQE heartbeat,
signifying a valid 10Base-T connection.
Status
Blinks yellow from one to eleven times to indicate system
status. Each pulse pattern is separated by a 2 second
“off” period. Greater pulse patterns have higher priority
(buffer saturation has greater priority than an empty MAC
table). Valid system statuses are:
1 pulse—system status is okay
2 pulses —no MAC entries in the MAC Address Table
3 pulses—Clear to Send (CTS) or Carrier Detect (DCD)
from base unit are not asserted
4 pulses—IM1/I buffer is saturated
5 pulses —WAN receive frame(s) too large
6 pulses —WAN receive frame(s) not octet aligned
7 pulses—WAN receive frame(s) aborted
8 pulses—Detected WAN receive frame(s) with CRC
9 pulses—Detected LAN receive frame(s) too large
10 pulses—Detected LAN receive frame(s) not octet
aligned
11 pulses—Detected LAN receive frame(s) with bad
CRC
TM
(Active Yellow) Solid Yellow indicates an Active Test
Mode.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
6.3 OPERATING LINE LOOPBACK (LL)
The Line Loopback (LL) test checks the operation of the local Model
2707/I, and is performed separately on each unit.
G.703 NTU
Model 2707/I
Network
2 Mbps G.703
Network
Ethernet
Device
Clocking
Data
Cable Span
Clock/
Data
Clock/
Data
Model
2707/I
Figure 12. Line loopback for a network termination application
To perform an LL test, set DIP switch S1-2 to On. The TM LED will be lit
while the unit is in loopback test mode.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX A
G.703 SPECIFICATIONS
A.1 NETWORK DATA RATE
2.048 Mbps
A.2 NETWORK CONNECTOR
RJ-48C/Dual Coax BNC
A.3 NOMINAL IMPEDANCE
75/120 ohm
A.4 LINE CODING
Selectable AMI or HDB3
A.5 LINE FRAMING
G.703 (Unframed)
A.6 CLOCKING
Internal or Network (Receive Recover)
A.7 DISTANCE
Maximum 6,000 ft (1.6 km) On 24 AWG cable
20
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX B
ETHERNET 10BASE-T SPECIFICATIONS
B.1 DTE INTERFACE
10Base-T on RJ-45F
B.2 DTE DATA RATES
10 Mbps
B.3 LAN CONNECTION
RJ-45, 10Base-T, 802.3 Ethernet
B.4 PROTOCOL
PPP (RFC 1661) with Bridging Control (RFC 1638)
B.5 MAC ADDRESS TABLE SIZE
4096 entries
B.6 MAC ADDRESS AGING
MAC addresses deleted after 8 minutes of inactivity
B.7 FRAME BUFFER
512 Frames
B.8 FRAME LATENCY
1 frame
B.9 DIAGNOSTICS
Line Loopback
B.10 INDICATORS
E-1 Link, 10Base-T Link, Ethernet Status, Test Mode
B.11 CONFIGURATION
8-Position DIP Switch
21
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX C
FACTORY REPLACEMENT PARTS AND ACCESSORIES
Patton Model #
Description
2707/C
2707/D
G.703 NTU with a V.35 interface
G.703 NTU with an X.21 interface
G.7034 NTU with 10Base-T ethernet interface
Universal Input Power Supply
User Manual
2707/I
08055DCUI
07M2707/I
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Copyright © 2000, 2001
Patton Electronics Company
All Rights Reserved.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
|