Paradyne Network Card 8021 User Manual

®
Hotwire Shelf Concentration Module (SCM) Card  
Installation Instructions  
Document Number 8021-A2-GZ40-20  
November 2000  
What is a Hotwire Shelf Concentration Module?  
A Hotwire® Shelf Concentration Module (SCM) is a circuit card assembly (CCA)  
that contains a parentcard with an ATM switch, a backplane interface, a processor,  
a cell mux/demux, and an uplink childcard. The childcard determines the type of  
ATM uplink supported by the SCM.  
When the SCM card is used in a Hotwire 8820 GranDSLAM chassis, it aggregates  
DSL traffic from each of the DSL port cards in the chassis on the chassis’  
backplane bus and concentrates it onto an ATM interface. The model number of  
the SCM card differs, depending on what type of ATM uplink childcard is being  
used.  
SCM Card Model  
ATM Uplink Childcard  
8021  
8022  
8023  
8024  
8025  
8026  
8027  
8028  
DS3  
OC3 with multi-mode fiber  
OC3 with single-mode fiber for immediate reach (15 km)  
OC3 single-mode fiber for long reach (40 km)  
E3  
DS1 IMA (ATM Inverse Multiplexing)  
E1 IMA (75 ohm)  
E1 IMA (120 ohm)  
8021-A2-GZ40-20  
November 2000  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the SCM Card  
Procedure  
To install the Hotwire SCM Card in Slot A of the GranDSLAM chassis:  
1. If there is a filler plate covering the slot, remove it.  
2. Remove the yellow screw covers.  
3. Insert the card into the card guides of the slot on the chassis.  
4. Carefully slide the card into the slot. Lift the insertion/ejection levers away from  
the faceplate until the card begins to engage the connectors on the backplane.  
Then press in on the insertion/ejection levers until the card is fully seated.  
5. Verify that the OK SYSTEM indicator on the cards faceplate is ON (winking  
green). If not, refer to the appropriate Hotwire GranDSLAM Installation Guide.  
6. Secure the card by fastening the screws on each end of the faceplate. This is  
required to maintain proper gasket pressure on the faceplate as well as proper  
air flow.  
7. Attach appropriate connections (e.g., DS3, OC3, etc.) to the uplink.  
NOTE:  
The IMA uplink has a RJ48M 50-pin connector. See IMA Uplink Card  
Connector Pinouts on page 4 for more information.  
8021-A2-GZ40-20  
November 2000  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMA Uplink Card Connector Pinouts  
The IMA uplink has a RJ48M 50-pin Telco connector with 8 Tip/Ring and  
8 Tip1/Ring1 connections that conforms to ANSI T1.403-1999. Paradyne offers an  
octopus cable for use with the IMA uplink (Feature No. 8026-F1-001 for Models  
8026 and 8028, and Feature No. 8027-F1-001 for Model 8027). These cables  
contain a required ferrite to meet EMI requirements. If purchasing other Telco  
cables, you must attach the supplied ferrite and cable tie as shown below. Contact  
your service representative for more information.  
When connecting the Telco cable, a .87-inch long panhead screw and cable tie  
must be used to mount the cable to the 50-pin Telco connector as shown below.  
SY  
S
TE  
M
OK  
Alrm  
T
est  
Uplink Alr  
E
TH  
m
E
R
N
E
T
TX  
RX  
Coll  
Panhead Screw  
Supplied  
Cable Tie  
Mount  
Cable Tie  
A
1-120  
-IM  
M
C
S
E
Ferrite  
8028  
Cable Tie  
00-16893  
4
November 2000  
8021-A2-GZ40-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 1 lists connector pin assignments for Models 8026 and 8028. Table 2 lists  
connector pin assignments for Model 8027.  
Table 1. Feature No. 8026-F1-001 Connector Pin Assignments (1 of 2)  
DS1 or 120 Ohm  
E1 Port  
RJ48M 50-Pin Telco RJ48C Connector  
Connector Pinouts  
Pinouts  
Function  
Port 1  
Port 2  
Port 3  
Port 4  
Port 5  
Port 6  
Port 7  
27  
2
5
4
2
1
5
4
2
1
5
4
2
1
5
4
2
1
5
4
2
1
5
4
2
1
5
4
2
1
Data Out (Tip)  
Data Out (Ring)  
Data In (Tip)  
26  
1
Data In (Ring)  
Data Out (Tip)  
Data Out (Ring)  
Data In (Tip)  
30  
5
29  
4
Data In (Ring)  
Data Out (Tip)  
Data Out (Ring)  
Data In (Tip)  
33  
8
32  
7
Data In (Ring)  
Data Out (Tip)  
Data Out (Ring)  
Data In (Tip)  
36  
11  
35  
10  
39  
14  
38  
13  
42  
17  
41  
16  
45  
20  
44  
19  
Data In (Ring)  
Data Out (Tip)  
Data Out (Ring)  
Data In (Tip)  
Data In (Ring)  
Data Out (Tip)  
Data Out (Ring)  
Data In (Tip)  
Data In (Ring)  
Data Out (Tip)  
Data Out (Ring)  
Data In (Tip)  
Data In (Ring)  
8021-A2-GZ40-20  
November 2000  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 1. Feature No. 8026-F1-001 Connector Pin Assignments (2 of 2)  
DS1 or 120 Ohm  
E1 Port  
RJ48M 50-Pin Telco RJ48C Connector  
Connector Pinouts  
Pinouts  
Function  
Port 8  
48  
23  
47  
22  
5
4
2
1
Data Out (Tip)  
Data Out (Ring)  
Data In (Tip)  
Data In (Ring)  
Table 2. Feature No. 8027-F1-001 Connector Pin Assignments (1 of 2)  
RJ48M 50-Pin Telco  
75 Ohm E1 Port  
Function  
Connector Pinouts  
BNC Connector  
Shell (Ring)  
Pin (Tip)  
Port 1  
Data In  
1
26  
2
Data Out  
Data In  
Shell (Ring)  
Pin (Tip)  
27  
4
Port 2  
Port 3  
Port 4  
Port 5  
Shell (Ring)  
Pin (Tip)  
29  
5
Data Out  
Data In  
Shell (Ring)  
Pin (Tip)  
30  
7
Shell (Ring)  
Pin (Tip)  
32  
8
Data Out  
Data In  
Shell (Ring)  
Pin (Tip)  
33  
10  
35  
11  
36  
13  
38  
14  
39  
Shell (Ring)  
Pin (Tip)  
Data Out  
Data In  
Shell (Ring)  
Pin (Tip)  
Shell (Ring)  
Pin (Tip)  
Data Out  
Shell (Ring)  
Pin (Tip)  
6
November 2000  
8021-A2-GZ40-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 2. Feature No. 8027-F1-001 Connector Pin Assignments (2 of 2)  
RJ48M 50-Pin Telco  
75 Ohm E1 Port  
Function  
Connector Pinouts  
BNC Connector  
Shell (Ring)  
Pin (Tip)  
Port 6  
Data In  
16  
41  
17  
42  
19  
44  
20  
45  
22  
47  
23  
48  
Data Out  
Data In  
Shell (Ring)  
Pin (Tip)  
Port 7  
Port 8  
Shell (Ring)  
Pin (Tip)  
Data Out  
Data In  
Shell (Ring)  
Pin (Tip)  
Shell (Ring)  
Pin (Tip)  
Data Out  
Shell (Ring)  
Pin (Tip)  
8021-A2-GZ40-20  
November 2000  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCM Card LEDs  
The following table describes the meaning and states of the LEDs on the Hotwire  
SCM card faceplate. Example faceplates are shown at left.  
Type  
LED  
LED is . . . Indicating . . .  
SYSTEM  
OK  
Green,  
Card functioning normally. Winking  
Winking  
describes a recurring pulse when the  
LED is ON longer than OFF at a ratio  
of approximately 10:1.  
Green, On  
Off  
SCM card failure. System processing  
functions have stopped.  
No power to card.  
Alrm  
Test  
Yellow, On  
Off  
Alarm is present on SCM.  
No alarms.  
Yellow, On  
Off  
Test in progress.  
No tests.  
Uplink  
Alrm  
Yellow, On  
Off  
Alarm is present on the ATM uplink.  
No alarms.  
ETHERNET TX  
Green,  
Blinking  
Currently not used.  
Currently not used.  
Currently not used.  
Off  
RX  
RX  
Green,  
Blinking  
Off  
Off  
Coll  
TX  
Yellow,  
Blinking  
TX  
RX  
SCM-DS3  
10/100BT  
SCM-OC3  
MMF  
SCM-IMA  
E1-75  
8021  
8022  
8027  
00-16891  
99-16634  
99-16635  
8
November 2000  
8021-A2-GZ40-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCM Card Technical Specifications  
Table 3. SCM Card Technical Specifications (1 of 2)  
Specifications  
Criteria*  
Size  
Length: 10.4 inches (26.42 cm)  
Height: 11.15 inches (28.32 cm)  
Width: 1.0 inches (2.54 cm)  
Weight  
Approximately 1.4 lbs. (0.64 kg)  
Approvals  
Safety Certifications  
Refer to the equipments label for approvals on product.  
Power  
The SCM card contains a DC-to-DC converter that requires  
48V power input. The 48V power is distributed through the  
Hotwire chassis backplane.  
Typical Power Dissipation = 26 watts (DS3 and E3)  
or 28 watts (OC3) or 24 watts (IMA)  
Physical Environment  
Operating temperature  
Storage temperature  
Relative humidity  
32° to 140° F (0° to 60° C)  
4° F to 158° F (20° C to 70° C)  
5% to 85% (noncondensing)  
Shock and vibration  
Withstands normal shipping and handling.  
Physical Characteristics  
Internal ATM Switching  
Fabric  
Modular Architecture from 622 Mbps to 5 Gbps,  
8192 virtual circuits  
DS3 Uplink Specifications  
Number of ports  
1 DS3  
BNC  
Connector Type  
Standards Supported  
ANSI T1.404-94 Electrical and Jitter, ANSI T1.102-93  
Electrical and Jitter  
Frame Formats  
Direct or PCLP  
B3ZS  
Line Type  
Data Rates Supported  
Facility Datalink Protocol  
44.736 Mbps  
ANSI T1.107.95 Format, ANSI T1.646-95 Format, ANSI  
T1.646 HEC, ITU-T I.432 Scrambler  
Cable Distance  
75 ohm coaxial 900 feet  
* Criteria of technical specifications are subject to change without notice.  
8021-A2-GZ40-20  
November 2000  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 3. SCM Card Technical Specifications (2 of 2)  
Specifications  
Criteria*  
OC3 Uplink Specifications  
Number of ports  
1 OC3  
Connector Type  
Fiber SC connectors  
Standards Supported  
ANSI T1.105.06-94 Jitter, ANSI T1.105.09 94 Jitter,  
ANSI T1.117.06-91, ITU-T G.957 7/95  
Frame Formats  
OC3 or STM-1 Operation, Direct Mode only  
Non-Return to Zero  
Line Type  
Data Rates Supported  
Facility Datalink Protocol  
155.52 Mbps  
ANSI T1.105 Format, ANSI T1.646 HEC, ITU-T I.432  
Scrambler  
Cable Distance  
Model 8022 (MMF)  
Model 8023 (SMFIR)  
Model 8024 (SMFLR)  
2 Km (6561.7 feet)  
15 Km (49,212.6 feet) SMF fiber  
40 Km (131,234 feet) SMF fiber  
E3 Uplink Specifications  
Number of ports  
1 E3  
Connector Type  
BNC  
Standards Supported  
Frame Formats  
ETSI ETS 3000 689 Electrical and Jitter  
Direct or PCLP  
HDB3  
Line Type  
Data Rates Supported  
Facility Datalink Protocol  
34.368 Mbps  
ETSI ETS 300 686 PLCP, ETSI ETS 3000 689 Direct,  
ITU T1.646 HEC, ITU-T I.432 Scrambler  
Cable Distance  
75 ohm coaxial 900 feet (274.3 meters)  
IMA Uplink Specifications  
Number of ports  
8 T1 or E1  
Connector Type  
RJ-48M (50-pin telco)  
Standards Supported  
Frame Formats  
RFC 495, ANSI T1.403, ITU G.703/G.704  
T1: Superframe, extended Superframe  
E1: E1, E1-CRC  
Line Type  
T1: B8ZS  
E1: HDB3  
Data Rates Supported  
T1: 1.544 Mbps per T1 (max. 8 T1)  
E1: 2.048 Mbps per E1 (max. 8 E1)  
Facility Datalink Protocol  
Cable Distance  
ANSI T1.403  
T1/E1 (short haul): 200 meters (656 feet) (LBO=0, 7, 15,  
22 dB)  
T1/E1 (long haul): 2000 meters (6561.7 feet)  
* Criteria of technical specifications are subject to change without notice.  
10  
November 2000  
8021-A2-GZ40-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty, Sales, Service, and Training Information  
Contact your local sales representative, service representative, or distributor  
directly for any help needed. For additional information concerning warranty, sales,  
service, repair, installation, documentation, training, distributor locations, or  
Paradyne worldwide office locations, use one of the following methods:  
Internet: Visit the Paradyne World Wide Web site at www.paradyne.com.  
(Be sure to register your warranty at www.paradyne.com/warranty.)  
Telephone: Call our automated system to receive current information by fax  
or to speak with a company representative.  
Within the U.S.A., call 1-800-870-2221  
Outside the U.S.A., call 1-727-530-2340  
Document Feedback  
We welcome your comments and suggestions about this document. Please mail  
them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo,  
FL 33773, or send e-mail to [email protected]. Include the number and  
title of this document in your correspondence. Please include your name and  
phone number if you are willing to provide additional clarification.  
Trademarks  
Hotwire is a registered trademark of Paradyne Corporation. MVL is a trademark of  
Paradyne Corporation. All other products and services mentioned herein are the  
trademarks, service marks, registered trademarks, or registered service marks of  
their respective owners.  
Copyright © 2000 Paradyne Corporation. Printed in U.S.A.  
8021-A2-GZ40-20  
November 2000  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Ventilation Hood M Nr 09 805 980 User Manual
MTD Snow Blower H660G User Manual
Musical Fidelity CD Player M1CDT User Manual
Nady Systems Headphones HM 35 User Manual
NEC Answering Machine NEAX2000IPS User Manual
Nissan Automobile Z12 D User Manual
Olympus Battery Charger ET CK30 User Manual
Olympus Microcassette Recorder VN 180 VN 90 User Manual
Oreck Air Cleaner ProShield Air Purifier User Manual
Panasonic Car Video System DVDXV10 User Manual