Olympus Microscope Magnifier PM10SP User Manual

AUTOMATIC PHOTOMICROGRAPHIC SYSTEM  
PM10SP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Simple operation based on easy-to-  
read LCD display  
Extend your capabilities with PM series  
accessories  
The control box features a minimum of  
buttons to ensure simple, straightforward  
operation. Settings are clearly shown on  
the LCD display and changed by simply  
pushing the buttons. 35mm/large-format  
camera selection is performed  
Compatibility with large-format and  
Polaroid camera operation as well as  
35mm SLR. For 35mm film, DX code  
sensing is automatic, to ensure correct ISO  
setting every time. 35mm film  
loading/winding/rewinding are all  
automatic, to prevent setting and operating  
errors.  
Extra editing convenience: data imprinting  
units are available for 35mm and Polaroid  
3 1/44 1/4 cameras.  
Foot switch available for foot-operated  
shutter release.  
automatically.  
Photography conditions are easy to  
confirm even in the dark, thanks to the  
clear graphical display of shutter speed,  
measuring area, film number, camera  
format, exposure compensation and  
compensation for reciprocity failure.  
Camera backs and adapters for camera backs  
A variety of adapters for different kinds of  
microscopes and a wide range of  
magnification photo eyepieces are also  
available.  
Data imprinting control box  
Data imprinting unit  
Convenient palm-sized control box  
saves desk space  
The palm-sized control box saves desk  
space, and enables setting adjustments to  
be made without unnecessary hand  
movements. The ability to confirm  
operating conditions without looking up lets  
the user work more efficiently.  
100% light Path.  
1% spot measuring to accommodate  
specimens for fluorescence  
observation  
The PM10SP employs Olympus-  
developed original IC measuring. Highly  
precise exposure control is possible  
through 30% average measuring (suitable  
for brightfield observation) and 1% spot  
measuring for both scattered specimens in  
darkfield observation and observation of  
bright fluorescence specimens.  
The 100% light path with built-in memory  
allows 100% of the light to reach the film.  
Accurate metering of 50% of the light  
intensity allows 50% of the light to be  
diverted to the viewer for easy framing,  
even for dark specimens. The anti-vibration  
shutter mechanism combined with direct  
100% exposure capability (performed by  
pushing the mirror aside with a cam)  
ensures clear, sharp pictures even at high  
shutter speeds.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Item  
Specifications  
Photometric modes  
Light distribution  
Auto mode/ Manual mode/ Time mode  
Measuring Viewer: 50% Meter: 50%  
Exposure Camera: 100%  
Photocell  
Split type (1% and 30%) silicon-photodiode (Olympus developed)  
1% spot / 30% average  
Measured area  
Auto exposure adjustment range  
ISO setting range  
1/125 sec.-21.2 min. (35mm camera, ISO100, reciprocity failure adjustment: standard[4])  
3-25,600(exposure compensation 1.00), increment of 1/3,  
Automatic ISO setting via DX code (manual setting is also possible)  
Exposure adjustment range  
Reciprocity failure correction  
Manual exposure time setting  
Display  
0.25-4.00(±2EV)  
3-step adjustments  
1/100 sec.-40 min. (52 steps), Time mode setting  
LCD display (with adjustable backlight function), LED display for exposure warning and working conditions.  
Acceptable cameras  
35mm camera (automatic film advance and rewinding), large-format camera (4"5"),  
Polaroid camera (3 1/4"4 1/4")  
Others  
AE-lock and Multi exposure  
Reset function for frame count numbers (Large-format camera)  
With terminal for release from outside  
Power consumption  
15VA (with AC adapter)  
Dimensions  
Automatic Exposure Body  
AC adapter  
Control Box  
118.5  
47.63  
75  
43.5  
PM10SP  
MODE  
120  
0.25  
AEL  
0.5  
1
2
4
SPOT MODE  
EXPOSE  
T-OFF  
105  
84.1  
41  
64  
108.8  
UYCP cord connection  
ø60  
76  
57.3  
80.3  
ISO9001  
ISO14001  
Certification  
Certification  
Design and production at the Olympus  
Optical Co. Ltd. Ina Plant conforms with  
ISO14001 specifications for  
Design and production  
adheres to ISO9001  
Accredited by the  
Dutch Council for  
Accreditation  
ISO 9001  
internationalquality standard.  
environmental management systems.  
Specifications are subject to change without any obligation on the part of the manufacturer.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Muratec Fax Machine MFX 1500E User Manual
Muse electronic DVD Player Model Eleven User Manual
NEC Computer Monitor A500+TM User Manual
NEC Server 320Lc R User Manual
Nokia TV Receiver 9802 S User Manual
North Star Digital Camera S205 User Manual
Olympus Double Oven VN 1800 User Manual
Optimus VCR 16 549 User Manual
P3 International Home Safety Product P7050 User Manual
Patton electronic Network Router 07MSN5300 QS User Manual