NuTone Ventilation Hood NP64000 User Manual

INSTALLATION INSTRUCTIONS  
HB0056  
NP64000 SERIES  
! INTENDED FOR DOMESTIC COOKING ONLY !  
READ AND SAVE THESE INSTRUCTIONS  
INSTALLER: LEAVE THIS MANUAL TO HOMEOWNER.  
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 11 TO 13  
NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)  
V07451 rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- NP64000 SERIES RANGE HOOD SYSTEM -  
INTERIOR BLOWERS  
Model 647  
(7” Rd wall cap)  
Model 634 or 644  
(roof cap)  
Model 643  
(8” Rd wall cap)  
Model 418  
10” round  
adjustable elbow  
(optional)  
Model 415  
7” round adjustable  
elbow (optional)  
8” round  
standard  
duct  
Model 407  
(7” round -  
2 ft. sections)  
Model 412  
Model 459 transition  
(31/4” x 14” to 8”)  
Model 413  
transition  
(31/4” x 10” to 7”)  
transition  
(31/4” x 10” to 8”)  
Standard duct  
(31/4” x 10”)  
Duct  
(31/4” x 14”)  
Adapter and damper 31/4” x 10”  
(supplied with P5 blower)  
Adapter and damper 31/4’’ x 14’’  
(supplied with P8 blower)  
Flow deviator  
(vertical exhaust only)  
(supplied with P5 and P8 blowers)  
NP64000 SERIES HOOD  
Model P8 dual-blower (900 cfm)  
for use with 36’’ hoods or wider  
Rough-in kit  
(supplied with P5 and P8 blowers)  
Model P5  
single-blower  
(500 cfm)  
NOTE: The dual blower P8 must be  
1
installed with 3 /4’’ x 14’’ duct. If it  
is impossible to connect the dual  
1
blower P8 to a 3 /4’’ x 14’’ duct,  
1
use a 3 /4’’ x 10’’ duct. In that  
case, the blower performance  
will be 25% decreased.  
RMP Series Backsplash  
(Stainless Steel wall  
covering with warming  
shelves. Optional)  
HL0070  
- 3 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- NP64000 SERIES RANGE HOOD SYSTEM -  
IN-LINE AND EXTERIOR BLOWERS  
Model 441  
Model 437  
(10” Rd wall cap)  
Model HLB9 (800 cfm)  
or HLB11 (1100 cfm)  
in-line blower  
(includes two 8” x 12” to  
10’’ round transitions)  
(High capacity roof cap)  
Model 335 (1200 cfm)  
or 336 (1500 cfm)  
exterior blower  
Model 331H (600 cfm)  
or 332H (900 cfm)  
exterior blower  
Model 441  
(10” Rd wall cap)  
Model HLB6 (600 cfm)  
in-line blower  
(includes two 4½” x 18½”  
to 10’’ round transitions)  
Model 421  
Model 418  
10” Rd  
(10” Rd. vert.  
in-line damper)  
Recommended  
for use with  
adjustable elbow  
(optional)  
Model HLB3 (280 cfm)  
in-line blower  
exterior blowers  
(includes one 8” to 10”  
round transition)  
Model 410  
(10” Rd duct -  
2ft. sections)  
NP64000 SERIES HOOD  
332KR in-line and exterior blower  
rough-in kit - Purchase separately.  
RMP Series Backsplash  
(Stainless Steel wall  
covering with warming  
shelves. Optional)  
HL0071  
- 4 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. SELECT BLOWER OPTION AND INSTALL DUCTWORK  
Either an interior or exterior blower or in-line blower may be used with this hood.The NuTone premier NP64000 Series must  
be installed with blower models P5, P8, HLB3, HLB6, HLB9, HLB11, 331H, 332H, 335 or 336 only. Other blowers  
cannot be substituted. (Blowers sold separately).  
Plan where and how the ductwork will be installed.  
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 3, 6, 9, 10,  
12 and up of this manual.  
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7” or 8” round  
ducts, or 31/4’’ x 14’’ duct, use a transition. Use 2” duct tape to seal duct joints.  
The minimum hood distance above cooktop must not be less than 20’’ for an electric range and 24’’ for a gas  
range. A maximum of 30” above cooktop is highly recommended for best capture of cooking impurities.  
Distances over 30” are at the installer and users discretion.  
Roof cap  
Roof cap  
x 14to 8”  
transition if  
7” or 8”  
round duct  
x 14duct  
Wall  
cap  
3¼” x 10” to 7”  
or 8” transition  
x 10or  
x 14duct  
Wall  
cap  
Hood with  
interior blower  
Hood  
20” minimum above  
cooking surface  
(24” for gas)  
20” minimum above  
cooking surface  
(24” for gas)  
HH0029A  
HH0015A  
MODEL P5 (SINGLE) OR  
MODEL P5 (SINGLE) OR  
P8 (DOUBLE) INTERIOR BLOWER  
TYPICAL RECTANGULAR DUCTWORK  
P8 (DOUBLE) INTERIOR BLOWER  
7’’ OR 8’’ ROUND DUCTWORK  
Exterior blower  
Roof cap  
10” round duct  
In-line blower  
10” round duct  
Hood  
Exterior  
blower  
Wall  
cap  
Hood  
20” minimum  
above cooking  
surface  
20” minimum above  
cooking surface  
(24” for gas)  
(24” for gas)  
HH0016A  
HH0060A  
MODEL 331H, 332H, 335 OR 336  
EXTERIOR BLOWER TYPICAL DUCTWORK  
MODEL HLB3, HLB6, HLB9 OR HLB11  
IN-LINE BLOWER TYPICAL DUCTWORK  
- 5 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. PREPARE THE INSTALLATION  
Make sure that the following items are included:  
- Range hood  
- Accessories:  
• Filters  
• Bag of parts including:  
(4) lock nuts, (1) wire clamp, (8) 1/2” double thread screws, (2) wire connectors,  
(2) 1/2” standard screws, (6) 3/  
screws.  
8
Parts sold separately:  
- Interior blower Model P5 includes blower, rough-in kit, flow deviator and 31/4” x 10” adapter  
- Interior blower Model P8 includes blower, rough-in kit, flow deviator and 31/4” x 10” adapter and 31/4” x 14” adapter  
- In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition)  
- In-line and exterior blower rough-in plate model 332KR, required for all In-line or Exterior Blowers  
- Exterior blower assembly 331H, 332H, 335 or 336  
- Halogen lights (120V, 50W, PAR 20)  
- Heat lamps (120V, IR 175W, PAR 38)  
- RMP Series Backsplash (optional)  
- Baffle filters (optional)  
- Transitions, duct, elbows, dampers, wall and roof caps. Refer to pages 3 and 4 for a complete list of venting options  
and model numbers.  
NOTE: For cabinets with recessed bottom, attach wood filler strips (not included) on each sides, as shown below.  
Use two (2) 2-inch wide strips for 30’’ wide hoods, and four (4) 2-inch wide strips for wider hoods, cut to length.  
See below for wood filler strip locations.  
HOOD  
WIDTHS  
30’’  
36’’  
42’’  
LOCATIONS  
B
A
C
N/A  
2’’  
2’’  
2’’  
4’’  
N/A  
41/2’’  
41/2’’  
81/4’’  
111/4’’  
71/4’’  
48’’  
101/4’’  
A
A
B
C
HD0079  
3. INSTALL BACKSPLASH (OPTIONAL)  
Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting  
screws. In order to be able to install the backsplash, make sure you have at least 18’’ clearance between bottom of  
hood and range control panel or cooktop. (See instructions packed with backsplash.)  
4. SELECT BLOWER OPTION (EXTERIOR OR INTERIOR)  
INTERIOR BLOWER:  
EXTERIOR BLOWER:  
Follow all subsequent steps of this manual.  
Refer to instructions packed with exterior blower and follow steps 6, 10, 12 and up of  
the present manual.  
- 6 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. CHOOSE THE OPENING (INTERIOR BLOWER)  
Remove the knockout for the chosen opening (horizontal at the back of the hood or vertical on rough-in plate).  
See pictures below.  
CAUTION  
When using P5 blower, remove the 10’’ wide knockout (smaller part). If using P8 blower, remove the  
knockout corresponding to the ducting installed (10’’ or 14’’).  
14’’ KNOCKOUT  
10’’ KNOCKOUT  
HD0076  
HD0077  
Removing horizontal knockout opening on back of hood  
Removing vertical knockout opening on rough-in plate  
6. INSTALL THE ROUGH-IN PLATE (ALL BLOWERS)  
INTERIOR BLOWER: Secure the rough-in plate (provided with the P5 and P8 blower) inside the hood with four (4)  
lock nuts. See picture below.  
HD0042  
EXTERIOR OR IN-LINE BLOWER: Purchase Model 332KR separately. Refer to instructions included with the rough-in  
kit. Secure the rough-in plate inside the hood with (4) lock nuts.  
7. INSTALL THE DEVIATOR (INTERIOR BLOWER)  
YOU MUST install the deviator if you choose to vent the hood vertically.  
Install the deviator as shown.  
NOTE: If installed correctly, the deviator will protrude about 1/8” above the  
rough-in plate.  
HD0003  
Inserting deviator into hood vertical opening  
- 7 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. INSTALL THE ADAPTER (INTERIOR BLOWER)  
1
Using two (2) standard /2’’ screws, secure the adapter to the top (or back) of the hood. Seal the adapter to the hood  
using duct tape.  
HD0005  
HD0006  
9. INSTALL THE HOOD (ALL BLOWERS)  
INTERIOR BLOWER: Run power cable to installation location. Place the hood to its location. Mark the position of the  
1
screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) /2” double thread screws  
leaving a 1/8” gap (4 screws for 30” hood). Remove wiring cover, place the wire clamp, insert the cable in the hood and  
tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it in position. Make sure the  
adapter/damper assembly enters the ducting. Secure the hood by tightening the screws completely.  
HD0043  
EXTERIOR OR IN-LINE BLOWER: Run power cable to installation location. Place the hood to its location. Mark the  
position of the screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2” double thread  
1
screws leaving a /8” gap (4 screws for 30” hood). Remove wiring cover on top of the hood and connect wiring (see  
instructions included with exterior or in-line blower). Place the hood under the cabinet and slide it in position. Secure  
the hood by tightening the screws completely.  
- 8 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. CONNECT WIRING (ALL BLOWERS)  
WARNING  
!
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with  
all applicable codes and standards. Before connecting wires, switch power off at service panel and  
lock service disconnecting means to prevent power to be switched on accidentally.  
INTERIOR BLOWER: Connect cable into wiring box using wire  
connectors.  
Connect wires as follow: BLACK to BLACK, WHITE to WHITE and  
GREEN or BARE wire under ground screw. Reinstall wiring cover. DO  
NOT FORGET TO CONNECT THE GROUND.  
HD0007  
1
1) Ground screw  
IN-LINE OR EXTERIOR BLOWER: Remove rough-in plate wiring cover and connect wiring (see instructions included  
witn in-line or exterior blower).  
11. INSTALL THE BLOWER (INTERIOR BLOWER)  
The blower must be installed to the rough-in plate using (4) 3/8” screws for the single blower unit and (6) 3/8” screws for  
the dual blower unit. Remove the cover from the blower assembly. Remove the impeller(s) by pulling them out gently  
(see pictures below).  
HD0022  
HD0021  
- 9 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11. INSTALL THE BLOWER (INTERIOR BLOWER) (CONT’D)  
Install screws into the location as shown in the pictures below (single blower or dual blower). Do not tighten screws down  
fully, leave a 1/8” gap. Hang blower unit onto blower plate (screws through the large part of the keyhole). Slide the blower  
to its position (screws in the small part of the keyhole). Tighten the screws.  
HD0044  
HD0044  
Single blower (P5)  
Dual blower (P8)  
Secure the blower by installing 2 more screws into the locations shown in the pictures below (single blower or dual  
blower). Reinstall impeller(s) and cover.  
HD0081  
HD0080  
Single blower (P5)  
Dual blower (P8)  
H D 0 0 2 3  
FRONT  
FOR DUAL BLOWER UNIT, MAKE  
SURE  
THE  
IMPELLERS  
ARE  
CORRECTLY INSTALLED, THE HOOD  
WILL NOT WORK PROPERLY IF  
REVERSED. Both impellers are different  
in the dual blower, one rotates clockwise  
and the other counterclockwise. Each  
wheel and motor have an arrow and a  
number on them, you have to match  
them correctly (see drawing beside).  
22  
1
HD0023  
WARNING  
!
Never plug the 2-prong blower cord to the 3-prong power supply cord.  
Plug the power supply to the 3-prong male connector (A) and  
the blower unit into the 2-prong female receptacle (B) inside the  
hood.  
A
B
HE0003  
- 10 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12. LIGHT BULBS  
This range hood uses 50W halogen lamps. (120V, 50W, PAR 20)  
Install the lamps by rotating them clockwise into their socket holder.  
13. HEAT LAMPS  
The heat lamps required are 120V, 175W max, infrared bulbs. (120V, IR 175W, PAR 38)  
White halogen lights can be used if warming shelves are not used. (120V, 90W, PAR 38)  
Install the lamps by rotating them clockwise into their socket holder.  
14. INSTALL FILTERS  
It is recommended to install side filters first and finish with center one(s).  
1.  
2.  
3.  
4.  
Insert upper end of filter into the hood (tab end).  
Raise lower end toward the inside of hood.  
Position lower end of filter into channel and pull on filter tab.  
While pulling the filter tab, slide the filter top under the inner retaining piece.  
Baffle filters are available as an option (see instruction sheet included with baffle filters).  
HD0009  
HD0010  
1
1) Tabs  
15. USE AND CARE  
Grease filters and impeller(s).  
The grease filters, impeller(s) and grease rail should be cleaned frequently. Use a warm detergent solution.  
Grease filters and impeller are dishwasher safe.  
Remove filters by pushing filters towards the back of hood and rotating filters downward.  
- 11 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. USE AND CARE (CONT’D)  
Hood cleaning  
Stainless steel cleaning: How to maintain its « BRIGHT LOOK »  
Do:  
- Regularly wash surfaces with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.  
- Always clean in the direction of original polish lines.  
- Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely.  
- You may also use a specialized household stainless steel cleaner.  
Don’t:  
- Do not use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.  
- Do not use any harsh or abrasive cleansers.  
- Do not allow dirt to accumulate.  
- Do not let plaster dust or any other construction residues reach the hood. During construction or renovation, cover  
the hood to make sure no dust sticks to stainless steel surface.  
Avoid: when choosing a detergent  
- Any cleaners that contain bleach will attack stainless steel.  
- Any products containing : chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.  
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive  
and should never be used close to a range.  
Enamel finish:  
Clean with warm water and mild detergent only. When discoloration occurs, use a good enamel polish such as auto-  
motive polish. (DO NOT use rough abrasive cleaner or porcelain cleaner.)  
16. OPERATION  
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few  
minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.  
1
1
2
4
HC0028  
3
1) Warming lamp switches  
2) Halogen light switches  
3) ON/OFF blower switch  
4) Blower speed control  
BLOWER  
The blower is operated using two (2) controls.  
Use the red, lighted on/off switch to start and stop the blower. When turned on, the blower will operate at the previous  
setting of the speed control.  
Turn the speed control knob clockwise to decrease blower speed – counterclockwise to increase speed.  
COOKTOP LIGHTING (HALOGEN)  
A double set of ON/OFF switches controls the halogen lights.  
The front rocker controls the center light (for 42” and 48” hoods). The rear rocker controls both side lights (each switch  
controls one light for 30” and 36” hood). Select one, two or three lights for best cooking lighting.  
Use PAR 20, 50W halogen bulbs.  
- 12 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16. OPERATION (CONT’D)  
WARNING  
!
Never place highly flammable material under warming lamps.  
WARMING LAMPS (INFRARED)  
Each warming lamp is controlled with its own ON/OFF switch.  
Use infrared light bulbs (120V, IR175W, PAR38) or white halogen bulbs (120V, 90W, PAR38) if food warming shelves are  
not used.  
HEAT SENTRY  
This hood is equipped with a Heat Sentry thermostat. This thermostat is a device that will turn on or speed up the blower  
if it senses excessive heat above the cooking surface.  
1) If blower is OFF - it turns blower ON to HIGH speed.  
2) If blower is ON at a lower speed setting – it turns the blower up to HIGH speed.  
WARNING  
!
The HEAT SENTRY can start the blower even if the hood is turned OFF. In this case, it is impossible  
to turn the blower OFF with blower switch. If you must stop the blower, do it from the main  
electrical panel.  
When the temperature level drops to normal, the blower will return to its original setting.  
WARRANTY  
NUTONE ONE-YEAR LIMITED WARRANTY  
NuTone warrants to the original consumer purchaser of its products that such products will be free from defects  
in materials or workmanship for a period of one year from the date of original purchase.THERE ARE NO OTHER  
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
During this one-year period, NuTone will, at its option, repair or replace, without charge, any product or part which  
is found to be defective under normal use and service.  
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been  
subject to misuse, negligence, accident, improper maintenance or repair (other than by NuTone), faulty installation  
or installation contrary to recommended installation instructions.  
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some  
states or provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not  
apply to you.  
NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE THE PURCHASER’S  
SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. NUTONE SHALL NOT BE LIABLE FOR  
INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH  
PRODUCT USE OR PERFORMANCE. Some states or provinces do not allow the exclusion or limitation of  
incidental or consequential damages, so the above limitation or exclusion may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state  
or province to another. This warranty supersedes all prior warranties.  
To qualify for warranty service, you must (a) notify NuTone at the addres or telephone number below, (b) give the  
model number and part identification and (c) describe the nature of any defect in the product or part. At the time  
of requesting warranty service, you must present evidence of the original purchase date.  
NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)  
- 13 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICE PARTS  
NP64000 Series  
1
17  
1
19  
16  
2
16  
18  
6
12  
3
11  
13  
5
14  
15  
4
16  
16  
16  
7
7
1
8
9 10  
1
HL0073  
KEY  
#
QTY (hood width)  
30” 36” 42” 48”  
PART NUMBER  
DESCRIPTION  
1
2
3
4
5
6
7
8
9
4
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
7
2
1
1
-
4
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
7
-
5
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
8
2
2
-
5
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
8
-
SOCKET LAMP  
V02264  
V02773  
V02772  
V03435  
V03436  
V03501  
V03507  
V03502  
V03503  
V03504  
V03505  
V03517  
V03518  
V03519  
V03520  
V00673  
V02512  
V01869  
V01582  
V00606  
V03509  
V03510  
V13216  
V13217  
V13218  
V13219  
V03686  
V02544  
V03598  
V07451  
MALE CONNECTOR  
FEMALE CONNECTOR  
THERMOSTAT  
THERMOSTAT BRACKET  
SPEED CONTROLLER  
SPST SINGLE SWITCH FOR WARMING LAMP  
SPST DOUBLE SWITCH FOR HALOGEN LIGHT  
SPST LIGHTED SINGLE SWITCH FOR BLOWER  
SPEED CONTROL BUTTON  
TERMINAL STRIP  
10" POWER CORDS  
10" CORDS FOR HEAT LAMP  
10" CONTROL WIRE  
10" LIGHTED SWITCH WIRE  
LOCK NUT #8-32  
SCREW #8-32 x 1/2" QUADREX  
MACHINE SCREW #6-32 x 1/4"  
LOCK NUT #6-32  
SCREW #8-3/8"T/B #8 HEAD  
RANGEMASTER FILTER 8.930  
RANGEMASTER FILTER 11.930  
GREASE RAIL 30"  
GREASE RAIL 36"  
GREASE RAIL 42"  
GREASE RAIL 48"  
FILTER CLIP  
HALOGEN LAMP PAR 20 50 W  
HEAT LAMP  
INSTALLATION GUIDE  
10  
11  
12  
13  
14  
15  
16  
x 9.800  
17  
3
-
1
-
4
-
-
x 9.800”  
-
1
-
4
3
2
1
18  
19  
-
-
3
2
2
1
-
-
1
4
3
2
1
3
2
2
1
PARTS BAG ((4) lock nut #10--32, (1) wire clamp LP16-AP, (2) wire connectors #74B,  
(8) double thread screw 6-12 x 0.5, (6) #8 x 3/8” screws, (2) #6 x 1/2" screws)  
1
1
1
1
V13278  
- 14 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICE PARTS  
SINGLE BLOWER/ROUGH-IN  
(Model P5)  
1
2
20  
21  
19  
23  
18  
22  
3
4
17  
5
6
16  
7
15  
14  
13  
6
8
12  
9
11  
10  
HL0021  
KEY  
PART NUMBER  
#
DESCRIPTION  
QTY  
ADAPTER AND DAMPER 31/4’’ x 10’’  
AIR DEFLECTOR  
1
1
1
1
1
4
1
1
1
1
1
1
3
3
2
1
1
4
1
1
1
1
1
2
2
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
V13296  
V03500  
V12997  
V03577  
V02160  
V01869  
V01857  
V01582  
V14973  
V01810  
V03400  
V01766  
V00871  
V02001  
V01831  
V11705  
V11614  
V01927  
V03495  
V03494  
V13230  
V03496  
V00660  
V05520  
V00613  
SINGLE BLOWER ROUGH-IN PLATE ASSEMBLY  
FOAM 1/2” x 1/2” x 12”  
CAPACITOR 15MFD  
MACHINE SCREW #6-32 x 1/  
4”  
WIRE COVER  
LOCK NUT #6-32  
SINGLE BLOWER ASSEMBLY  
IMPELLER RING  
BLOWER IMPELLER 7.094” x 3.375” CW  
MOTOR 165W CW  
WASHER 3/16” ID x 3/4’’ OD  
MOTOR GROMMET G-431-1  
8” TIE WRAP  
MOTOR MOUNT  
15  
WIRE #18 TEW BROWN x 10”  
METRIC SCREW M4 x 6MM PAN QDRX  
STRAIN RELIEF FOR BLOWER POWER CORD  
36” BLOWER POWER CORD  
OUTLET BOX COVER  
POWER CORD, 120 VOLTS  
STRAIN RELIEF FOR POWER CORD  
SCREW #8 x 3/8”, T/B, #8 HEAD  
SCREW #10-32 x 3/8, TF, GREEN  
16  
17  
18  
19  
20  
21  
22  
23  
- 15 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICE PARTS  
DUAL BLOWER/ROUGH-IN  
(Model P8)  
2
22  
24  
1
23  
25  
3
4
21  
19  
5
20  
18  
6
17  
16  
15  
14  
7
8
9
11  
13  
10  
12  
KEY  
PART NUMBER  
#
DESCRIPTION  
QTY  
ADAPTER AND DAMPER 31/4” x 14’’  
ADAPTER AND DAMPER 31/4” x 10’’  
AIR DEFLECTOR  
1
1
1
1
1
1
2
2
1
1
1
2
1
1
6
4
2
2
6
8
1
1
1
1
1
4
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
V14971  
V13296  
V03500  
V14975  
V03577  
V01582  
V02160  
V01857  
V01766  
V03400  
V14974  
V01810  
V03399  
V03457  
V00871  
V01831  
V11705  
V11614  
V02001  
V01927  
V03495  
V03494  
V14960  
V00660  
V03496  
V05520  
V00613  
DUAL BLOWER ROUGH-IN PLATE ASSEMBLY  
FOAM 1/2” x 1/2” x 12”  
LOCK NUT #6-32  
CAPACITOR 15MFD  
WIRE COVER  
MOTOR 165W CW  
BLOWER IMPELLER, HOOD 7.094” x 3.375” CW  
DUAL BLOWER ASSEMBLY  
IMPELLER RING  
BLOWER IMPELLER, HOOD 7.094” x 3.375” CCW  
MOTOR 165W CCW  
WASHER 3/16” ID x 3/4 OD  
8” TIE WRAP  
MOTOR MOUNT  
16  
WIRE #18 TEW BROWN x 10”  
MOTOR GROMMET G-431-1  
METRIC SCREW M4 x 6MM PAN QDRX  
STRAIN RELIEF FOR BLOWER POWER CORD  
36” BLOWER POWER CORD  
OUTLET BOX COVER  
STRAIN RELIEF FOR POWER CORD  
POWER CORD, 120 VOLTS  
SCREW #8 x 3/8”, T/B, #8 HEAD  
SCREW #10-32 x 3/8”, TF, GREEN  
17  
18  
19  
20  
21  
22  
23  
24  
25  
2
- 16 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Washer 09 848 440 User Manual
Multiquip Portable Generator DCA70USI User Manual
NAD DVD Player L 53 User Manual
Nokia Satellite TV System 9200S User Manual
North Star Portable Generator M165912I3 User Manual
Oki Fax Machine 56801 User Manual
Omega Beverage Dispenser B2100 User Manual
Palsonic CRT Television 5130G User Manual
Panasonic Car Stereo System CQ 5251JU User Manual
Panasonic Car Stereo System CQ DP875 User Manual