INSTALLATION INSTRUCTIONS
HB0056
NP64000 SERIES
! INTENDED FOR DOMESTIC COOKING ONLY !
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL TO HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 11 TO 13
NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
V07451 rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
- NP64000 SERIES RANGE HOOD SYSTEM -
INTERIOR BLOWERS
Model 647
(7” Rd wall cap)
Model 634 or 644
(roof cap)
Model 643
(8” Rd wall cap)
Model 418
10” round
adjustable elbow
(optional)
Model 415
7” round adjustable
elbow (optional)
8” round
standard
duct
Model 407
(7” round -
2 ft. sections)
Model 412
Model 459 transition
(31/4” x 14” to 8”)
Model 413
transition
(31/4” x 10” to 7”)
transition
(31/4” x 10” to 8”)
Standard duct
(31/4” x 10”)
Duct
(31/4” x 14”)
Adapter and damper 31/4” x 10”
(supplied with P5 blower)
Adapter and damper 31/4’’ x 14’’
(supplied with P8 blower)
Flow deviator
(vertical exhaust only)
(supplied with P5 and P8 blowers)
NP64000 SERIES HOOD
Model P8 dual-blower (900 cfm)
for use with 36’’ hoods or wider
Rough-in kit
(supplied with P5 and P8 blowers)
Model P5
single-blower
(500 cfm)
NOTE: The dual blower P8 must be
1
installed with 3 /4’’ x 14’’ duct. If it
is impossible to connect the dual
1
blower P8 to a 3 /4’’ x 14’’ duct,
1
use a 3 /4’’ x 10’’ duct. In that
case, the blower performance
will be 25% decreased.
RMP Series Backsplash
(Stainless Steel wall
covering with warming
shelves. Optional)
HL0070
- 3 -
Download from Www.Somanuals.com. All Manuals Search And Download.
- NP64000 SERIES RANGE HOOD SYSTEM -
IN-LINE AND EXTERIOR BLOWERS
Model 441
Model 437
(10” Rd wall cap)
Model HLB9 (800 cfm)
or HLB11 (1100 cfm)
in-line blower
(includes two 8” x 12” to
10’’ round transitions)
(High capacity roof cap)
Model 335 (1200 cfm)
or 336 (1500 cfm)
exterior blower
Model 331H (600 cfm)
or 332H (900 cfm)
exterior blower
Model 441
(10” Rd wall cap)
Model HLB6 (600 cfm)
in-line blower
(includes two 4½” x 18½”
to 10’’ round transitions)
Model 421
Model 418
10” Rd
(10” Rd. vert.
in-line damper)
Recommended
for use with
adjustable elbow
(optional)
Model HLB3 (280 cfm)
in-line blower
exterior blowers
(includes one 8” to 10”
round transition)
Model 410
(10” Rd duct -
2ft. sections)
NP64000 SERIES HOOD
332KR in-line and exterior blower
rough-in kit - Purchase separately.
RMP Series Backsplash
(Stainless Steel wall
covering with warming
shelves. Optional)
HL0071
- 4 -
Download from Www.Somanuals.com. All Manuals Search And Download.
1. SELECT BLOWER OPTION AND INSTALL DUCTWORK
Either an interior or exterior blower or in-line blower may be used with this hood.The NuTone premier NP64000 Series must
be installed with blower models P5, P8, HLB3, HLB6, HLB9, HLB11, 331H, 332H, 335 or 336 only. Other blowers
cannot be substituted. (Blowers sold separately).
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 3, 6, 9, 10,
12 and up of this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7” or 8” round
ducts, or 31/4’’ x 14’’ duct, use a transition. Use 2” duct tape to seal duct joints.
The minimum hood distance above cooktop must not be less than 20’’ for an electric range and 24’’ for a gas
range. A maximum of 30” above cooktop is highly recommended for best capture of cooking impurities.
Distances over 30” are at the installer and users discretion.
Roof cap
Roof cap
3¼” x 14” to 8”
transition if
7” or 8”
round duct
3¼” x 14” duct
Wall
cap
3¼” x 10” to 7”
or 8” transition
3¼” x 10” or
3¼” x 14” duct
Wall
cap
Hood with
interior blower
Hood
20” minimum above
cooking surface
(24” for gas)
20” minimum above
cooking surface
(24” for gas)
HH0029A
HH0015A
MODEL P5 (SINGLE) OR
MODEL P5 (SINGLE) OR
P8 (DOUBLE) INTERIOR BLOWER
TYPICAL RECTANGULAR DUCTWORK
P8 (DOUBLE) INTERIOR BLOWER
7’’ OR 8’’ ROUND DUCTWORK
Exterior blower
Roof cap
10” round duct
In-line blower
10” round duct
Hood
Exterior
blower
Wall
cap
Hood
20” minimum
above cooking
surface
20” minimum above
cooking surface
(24” for gas)
(24” for gas)
HH0016A
HH0060A
MODEL 331H, 332H, 335 OR 336
EXTERIOR BLOWER TYPICAL DUCTWORK
MODEL HLB3, HLB6, HLB9 OR HLB11
IN-LINE BLOWER TYPICAL DUCTWORK
- 5 -
Download from Www.Somanuals.com. All Manuals Search And Download.
2. PREPARE THE INSTALLATION
Make sure that the following items are included:
- Range hood
- Accessories:
• Filters
• Bag of parts including:
(4) lock nuts, (1) wire clamp, (8) 1/2” double thread screws, (2) wire connectors,
(2) 1/2” standard screws, (6) 3/
screws.
8
Parts sold separately:
- Interior blower Model P5 includes blower, rough-in kit, flow deviator and 31/4” x 10” adapter
- Interior blower Model P8 includes blower, rough-in kit, flow deviator and 31/4” x 10” adapter and 31/4” x 14” adapter
- In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition)
- In-line and exterior blower rough-in plate model 332KR, required for all In-line or Exterior Blowers
- Exterior blower assembly 331H, 332H, 335 or 336
- Halogen lights (120V, 50W, PAR 20)
- Heat lamps (120V, IR 175W, PAR 38)
- RMP Series Backsplash (optional)
- Baffle filters (optional)
- Transitions, duct, elbows, dampers, wall and roof caps. Refer to pages 3 and 4 for a complete list of venting options
and model numbers.
NOTE: For cabinets with recessed bottom, attach wood filler strips (not included) on each sides, as shown below.
Use two (2) 2-inch wide strips for 30’’ wide hoods, and four (4) 2-inch wide strips for wider hoods, cut to length.
See below for wood filler strip locations.
HOOD
WIDTHS
30’’
36’’
42’’
LOCATIONS
B
A
C
N/A
2’’
2’’
2’’
4’’
N/A
41/2’’
41/2’’
81/4’’
111/4’’
71/4’’
48’’
101/4’’
A
A
B
C
HD0079
3. INSTALL BACKSPLASH (OPTIONAL)
Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting
screws. In order to be able to install the backsplash, make sure you have at least 18’’ clearance between bottom of
hood and range control panel or cooktop. (See instructions packed with backsplash.)
4. SELECT BLOWER OPTION (EXTERIOR OR INTERIOR)
INTERIOR BLOWER:
EXTERIOR BLOWER:
Follow all subsequent steps of this manual.
Refer to instructions packed with exterior blower and follow steps 6, 10, 12 and up of
the present manual.
- 6 -
Download from Www.Somanuals.com. All Manuals Search And Download.
5. CHOOSE THE OPENING (INTERIOR BLOWER)
Remove the knockout for the chosen opening (horizontal at the back of the hood or vertical on rough-in plate).
See pictures below.
CAUTION
When using P5 blower, remove the 10’’ wide knockout (smaller part). If using P8 blower, remove the
knockout corresponding to the ducting installed (10’’ or 14’’).
14’’ KNOCKOUT
10’’ KNOCKOUT
HD0076
HD0077
Removing horizontal knockout opening on back of hood
Removing vertical knockout opening on rough-in plate
6. INSTALL THE ROUGH-IN PLATE (ALL BLOWERS)
INTERIOR BLOWER: Secure the rough-in plate (provided with the P5 and P8 blower) inside the hood with four (4)
lock nuts. See picture below.
HD0042
EXTERIOR OR IN-LINE BLOWER: Purchase Model 332KR separately. Refer to instructions included with the rough-in
kit. Secure the rough-in plate inside the hood with (4) lock nuts.
7. INSTALL THE DEVIATOR (INTERIOR BLOWER)
YOU MUST install the deviator if you choose to vent the hood vertically.
Install the deviator as shown.
NOTE: If installed correctly, the deviator will protrude about 1/8” above the
rough-in plate.
HD0003
Inserting deviator into hood vertical opening
- 7 -
Download from Www.Somanuals.com. All Manuals Search And Download.
8. INSTALL THE ADAPTER (INTERIOR BLOWER)
1
Using two (2) standard /2’’ screws, secure the adapter to the top (or back) of the hood. Seal the adapter to the hood
using duct tape.
HD0005
HD0006
9. INSTALL THE HOOD (ALL BLOWERS)
INTERIOR BLOWER: Run power cable to installation location. Place the hood to its location. Mark the position of the
1
screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) /2” double thread screws
leaving a 1/8” gap (4 screws for 30” hood). Remove wiring cover, place the wire clamp, insert the cable in the hood and
tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it in position. Make sure the
adapter/damper assembly enters the ducting. Secure the hood by tightening the screws completely.
HD0043
EXTERIOR OR IN-LINE BLOWER: Run power cable to installation location. Place the hood to its location. Mark the
position of the screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2” double thread
1
screws leaving a /8” gap (4 screws for 30” hood). Remove wiring cover on top of the hood and connect wiring (see
instructions included with exterior or in-line blower). Place the hood under the cabinet and slide it in position. Secure
the hood by tightening the screws completely.
- 8 -
Download from Www.Somanuals.com. All Manuals Search And Download.
10. CONNECT WIRING (ALL BLOWERS)
WARNING
!
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with
all applicable codes and standards. Before connecting wires, switch power off at service panel and
lock service disconnecting means to prevent power to be switched on accidentally.
INTERIOR BLOWER: Connect cable into wiring box using wire
connectors.
Connect wires as follow: BLACK to BLACK, WHITE to WHITE and
GREEN or BARE wire under ground screw. Reinstall wiring cover. DO
NOT FORGET TO CONNECT THE GROUND.
HD0007
1
1) Ground screw
IN-LINE OR EXTERIOR BLOWER: Remove rough-in plate wiring cover and connect wiring (see instructions included
witn in-line or exterior blower).
11. INSTALL THE BLOWER (INTERIOR BLOWER)
The blower must be installed to the rough-in plate using (4) 3/8” screws for the single blower unit and (6) 3/8” screws for
the dual blower unit. Remove the cover from the blower assembly. Remove the impeller(s) by pulling them out gently
(see pictures below).
HD0022
HD0021
- 9 -
Download from Www.Somanuals.com. All Manuals Search And Download.
11. INSTALL THE BLOWER (INTERIOR BLOWER) (CONT’D)
Install screws into the location as shown in the pictures below (single blower or dual blower). Do not tighten screws down
fully, leave a 1/8” gap. Hang blower unit onto blower plate (screws through the large part of the keyhole). Slide the blower
to its position (screws in the small part of the keyhole). Tighten the screws.
HD0044
HD0044
Single blower (P5)
Dual blower (P8)
Secure the blower by installing 2 more screws into the locations shown in the pictures below (single blower or dual
blower). Reinstall impeller(s) and cover.
HD0081
HD0080
Single blower (P5)
Dual blower (P8)
H D 0 0 2 3
FRONT
FOR DUAL BLOWER UNIT, MAKE
SURE
THE
IMPELLERS
ARE
CORRECTLY INSTALLED, THE HOOD
WILL NOT WORK PROPERLY IF
REVERSED. Both impellers are different
in the dual blower, one rotates clockwise
and the other counterclockwise. Each
wheel and motor have an arrow and a
number on them, you have to match
them correctly (see drawing beside).
22
1
HD0023
WARNING
!
Never plug the 2-prong blower cord to the 3-prong power supply cord.
Plug the power supply to the 3-prong male connector (A) and
the blower unit into the 2-prong female receptacle (B) inside the
hood.
A
B
HE0003
- 10 -
Download from Www.Somanuals.com. All Manuals Search And Download.
12. LIGHT BULBS
This range hood uses 50W halogen lamps. (120V, 50W, PAR 20)
Install the lamps by rotating them clockwise into their socket holder.
13. HEAT LAMPS
The heat lamps required are 120V, 175W max, infrared bulbs. (120V, IR 175W, PAR 38)
White halogen lights can be used if warming shelves are not used. (120V, 90W, PAR 38)
Install the lamps by rotating them clockwise into their socket holder.
14. INSTALL FILTERS
It is recommended to install side filters first and finish with center one(s).
1.
2.
3.
4.
Insert upper end of filter into the hood (tab end).
Raise lower end toward the inside of hood.
Position lower end of filter into channel and pull on filter tab.
While pulling the filter tab, slide the filter top under the inner retaining piece.
Baffle filters are available as an option (see instruction sheet included with baffle filters).
HD0009
HD0010
1
1) Tabs
15. USE AND CARE
Grease filters and impeller(s).
The grease filters, impeller(s) and grease rail should be cleaned frequently. Use a warm detergent solution.
Grease filters and impeller are dishwasher safe.
Remove filters by pushing filters towards the back of hood and rotating filters downward.
- 11 -
Download from Www.Somanuals.com. All Manuals Search And Download.
15. USE AND CARE (CONT’D)
Hood cleaning
Stainless steel cleaning: How to maintain its « BRIGHT LOOK »
Do:
- Regularly wash surfaces with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
- Always clean in the direction of original polish lines.
- Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely.
- You may also use a specialized household stainless steel cleaner.
Don’t:
- Do not use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.
- Do not use any harsh or abrasive cleansers.
- Do not allow dirt to accumulate.
- Do not let plaster dust or any other construction residues reach the hood. During construction or renovation, cover
the hood to make sure no dust sticks to stainless steel surface.
Avoid: when choosing a detergent
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing : chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive
and should never be used close to a range.
Enamel finish:
Clean with warm water and mild detergent only. When discoloration occurs, use a good enamel polish such as auto-
motive polish. (DO NOT use rough abrasive cleaner or porcelain cleaner.)
16. OPERATION
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few
minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
1
1
2
4
HC0028
3
1) Warming lamp switches
2) Halogen light switches
3) ON/OFF blower switch
4) Blower speed control
BLOWER
The blower is operated using two (2) controls.
Use the red, lighted on/off switch to start and stop the blower. When turned on, the blower will operate at the previous
setting of the speed control.
Turn the speed control knob clockwise to decrease blower speed – counterclockwise to increase speed.
COOKTOP LIGHTING (HALOGEN)
A double set of ON/OFF switches controls the halogen lights.
The front rocker controls the center light (for 42” and 48” hoods). The rear rocker controls both side lights (each switch
controls one light for 30” and 36” hood). Select one, two or three lights for best cooking lighting.
Use PAR 20, 50W halogen bulbs.
- 12 -
Download from Www.Somanuals.com. All Manuals Search And Download.
16. OPERATION (CONT’D)
WARNING
!
Never place highly flammable material under warming lamps.
WARMING LAMPS (INFRARED)
Each warming lamp is controlled with its own ON/OFF switch.
Use infrared light bulbs (120V, IR175W, PAR38) or white halogen bulbs (120V, 90W, PAR38) if food warming shelves are
not used.
HEAT SENTRY
This hood is equipped with a Heat Sentry thermostat. This thermostat is a device that will turn on or speed up the blower
if it senses excessive heat above the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting – it turns the blower up to HIGH speed.
WARNING
!
The HEAT SENTRY can start the blower even if the hood is turned OFF. In this case, it is impossible
to turn the blower OFF with blower switch. If you must stop the blower, do it from the main
electrical panel.
When the temperature level drops to normal, the blower will return to its original setting.
WARRANTY
NUTONE ONE-YEAR LIMITED WARRANTY
NuTone warrants to the original consumer purchaser of its products that such products will be free from defects
in materials or workmanship for a period of one year from the date of original purchase.THERE ARE NO OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, NuTone will, at its option, repair or replace, without charge, any product or part which
is found to be defective under normal use and service.
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been
subject to misuse, negligence, accident, improper maintenance or repair (other than by NuTone), faulty installation
or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some
states or provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not
apply to you.
NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE THE PURCHASER’S
SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. NUTONE SHALL NOT BE LIABLE FOR
INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
PRODUCT USE OR PERFORMANCE. Some states or provinces do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state
or province to another. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify NuTone at the addres or telephone number below, (b) give the
model number and part identification and (c) describe the nature of any defect in the product or part. At the time
of requesting warranty service, you must present evidence of the original purchase date.
NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
- 13 -
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE PARTS
NP64000 Series
1
17
1
19
16
2
16
18
6
12
3
11
13
5
14
15
4
16
16
16
7
7
1
8
9 10
1
HL0073
KEY
#
QTY (hood width)
30” 36” 42” 48”
PART NUMBER
DESCRIPTION
1
2
3
4
5
6
7
8
9
4
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
7
2
1
1
-
4
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
7
-
5
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
8
2
2
-
5
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
2
1
1
8
-
SOCKET LAMP
V02264
V02773
V02772
V03435
V03436
V03501
V03507
V03502
V03503
V03504
V03505
V03517
V03518
V03519
V03520
V00673
V02512
V01869
V01582
V00606
V03509
V03510
V13216
V13217
V13218
V13219
V03686
V02544
V03598
V07451
MALE CONNECTOR
FEMALE CONNECTOR
THERMOSTAT
THERMOSTAT BRACKET
SPEED CONTROLLER
SPST SINGLE SWITCH FOR WARMING LAMP
SPST DOUBLE SWITCH FOR HALOGEN LIGHT
SPST LIGHTED SINGLE SWITCH FOR BLOWER
SPEED CONTROL BUTTON
TERMINAL STRIP
10" POWER CORDS
10" CORDS FOR HEAT LAMP
10" CONTROL WIRE
10" LIGHTED SWITCH WIRE
LOCK NUT #8-32
SCREW #8-32 x 1/2" QUADREX
MACHINE SCREW #6-32 x 1/4"
LOCK NUT #6-32
SCREW #8-3/8"T/B #8 HEAD
RANGEMASTER FILTER 8.930
RANGEMASTER FILTER 11.930
GREASE RAIL 30"
GREASE RAIL 36"
GREASE RAIL 42"
GREASE RAIL 48"
FILTER CLIP
HALOGEN LAMP PAR 20 50 W
HEAT LAMP
INSTALLATION GUIDE
10
11
12
13
14
15
16
”
x 9.800
”
17
3
-
1
-
4
-
-
”
x 9.800”
-
1
-
4
3
2
1
18
19
-
-
3
2
2
1
-
-
1
4
3
2
1
3
2
2
1
PARTS BAG ((4) lock nut #10--32, (1) wire clamp LP16-AP, (2) wire connectors #74B,
(8) double thread screw 6-12 x 0.5, (6) #8 x 3/8” screws, (2) #6 x 1/2" screws)
1
1
1
1
V13278
- 14 -
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE PARTS
SINGLE BLOWER/ROUGH-IN
(Model P5)
1
2
20
21
19
23
18
22
3
4
17
5
6
16
7
15
14
13
6
8
12
9
11
10
HL0021
KEY
PART NUMBER
#
DESCRIPTION
QTY
ADAPTER AND DAMPER 31/4’’ x 10’’
AIR DEFLECTOR
1
1
1
1
1
4
1
1
1
1
1
1
3
3
2
1
1
4
1
1
1
1
1
2
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
V13296
V03500
V12997
V03577
V02160
V01869
V01857
V01582
V14973
V01810
V03400
V01766
V00871
V02001
V01831
V11705
V11614
V01927
V03495
V03494
V13230
V03496
V00660
V05520
V00613
SINGLE BLOWER ROUGH-IN PLATE ASSEMBLY
FOAM 1/2” x 1/2” x 12”
CAPACITOR 15MFD
MACHINE SCREW #6-32 x 1/
4”
WIRE COVER
LOCK NUT #6-32
SINGLE BLOWER ASSEMBLY
IMPELLER RING
BLOWER IMPELLER 7.094” x 3.375” CW
MOTOR 165W CW
WASHER 3/16” ID x 3/4’’ OD
MOTOR GROMMET G-431-1
8” TIE WRAP
MOTOR MOUNT
15
WIRE #18 TEW BROWN x 10”
METRIC SCREW M4 x 6MM PAN QDRX
STRAIN RELIEF FOR BLOWER POWER CORD
36” BLOWER POWER CORD
OUTLET BOX COVER
POWER CORD, 120 VOLTS
STRAIN RELIEF FOR POWER CORD
SCREW #8 x 3/8”, T/B, #8 HEAD
SCREW #10-32 x 3/8, TF, GREEN
16
17
18
19
20
21
22
23
- 15 -
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE PARTS
DUAL BLOWER/ROUGH-IN
(Model P8)
2
22
24
1
23
25
3
4
21
19
5
20
18
6
17
16
15
14
7
8
9
11
13
10
12
KEY
PART NUMBER
#
DESCRIPTION
QTY
ADAPTER AND DAMPER 31/4” x 14’’
ADAPTER AND DAMPER 31/4” x 10’’
AIR DEFLECTOR
1
1
1
1
1
1
2
2
1
1
1
2
1
1
6
4
2
2
6
8
1
1
1
1
1
4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
V14971
V13296
V03500
V14975
V03577
V01582
V02160
V01857
V01766
V03400
V14974
V01810
V03399
V03457
V00871
V01831
V11705
V11614
V02001
V01927
V03495
V03494
V14960
V00660
V03496
V05520
V00613
DUAL BLOWER ROUGH-IN PLATE ASSEMBLY
FOAM 1/2” x 1/2” x 12”
LOCK NUT #6-32
CAPACITOR 15MFD
WIRE COVER
MOTOR 165W CW
BLOWER IMPELLER, HOOD 7.094” x 3.375” CW
DUAL BLOWER ASSEMBLY
IMPELLER RING
BLOWER IMPELLER, HOOD 7.094” x 3.375” CCW
MOTOR 165W CCW
WASHER 3/16” ID x 3/4 OD
8” TIE WRAP
MOTOR MOUNT
16
WIRE #18 TEW BROWN x 10”
MOTOR GROMMET G-431-1
METRIC SCREW M4 x 6MM PAN QDRX
STRAIN RELIEF FOR BLOWER POWER CORD
36” BLOWER POWER CORD
OUTLET BOX COVER
STRAIN RELIEF FOR POWER CORD
POWER CORD, 120 VOLTS
SCREW #8 x 3/8”, T/B, #8 HEAD
SCREW #10-32 x 3/8”, TF, GREEN
17
18
19
20
21
22
23
24
25
2
- 16 -
Download from Www.Somanuals.com. All Manuals Search And Download.
|