Nortel Networks Server 555 7101 226 User Manual

555-7101-226  
555-7101-226  
CallPilot  
Installation and Configuration  
Part 2: 703t Server Hardware Installation  
Product release 2.02  
Standard 1.01  
November 2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CallPilot  
Installation and Configuration  
Part 2: 703t Server Hardware Installation  
Publication number:  
Product release:  
Document release:  
Date:  
555-7101-226  
2.02  
Standard 1.01  
November 2005  
Copyright © 2003 Nortel Networks. All Rights Reserved.  
Printed in Canada  
Information is subject to change without notice. Nortel Networks reserves the right to make  
changes in design or components as progress in engineering and manufacturing may  
warrant.  
The process of transmitting data and call messaging between the CallPilot server and the  
switch or system is proprietary to Nortel Networks. Any other use of the data and the  
transmission process is a violation of the user license unless specifically authorized in  
writing by Nortel Networks prior to such use. Violations of the license by alternative usage of  
any portion of this process or the related hardware constitutes grounds for an immediate  
termination of the license and Nortel Networks reserves the right to seek all allowable  
remedies for such breach.  
This page and the following page are considered the title page, and contain Nortel Networks  
and third-party trademarks.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*Nortel Networks, the Nortel Networks logo, the Globemark, and Unified Networks, BNR,  
CallPilot, DMS, DMS-100, DMS-250, DMS-MTX, DMS-SCP, DPN, Dualmode, Helmsman,  
IVR, MAP, Meridian, Meridian 1, Meridian Link, Meridian Mail, Norstar, SL-1, SL-100,  
Succession, Supernode, Symposium, Telesis, and Unity are trademarks of Nortel Networks.  
3COM is a trademark of 3Com Corporation.  
ACCENT is a trademark of Accent Software International Ltd.  
ADOBE is a trademark of Adobe Systems Incorporated.  
AMDEK is a trademark of Amdek Corporation.  
AT&T is a trademark of American Telephone and Telegraph Corporation.  
ATLAS is a trademark of Quantum Corporation.  
ACCENT is a trademark of Accent Software International Ltd.  
ATRIA is a trademark of Pure Atria Corporation.  
BLACKBERRY is a trademark of Research in Motion Limited.  
CASEWARE is a trademark of Caseware International, Inc.  
CONTINUUS is a trademark of Continuus Software Corporation.  
CRYSTAL REPORTS is a trademark of Seagate Software Inc.  
DEFINITY is a trademark of Avaya Inc.  
DIALOGIC, INTEL and VOICEBRIDGE are trademarks or registered trademarks of Intel  
Corporation or its subsidiaries in the United States and other countries.  
DIVX is a trademark of DivXNetworks, Inc.  
EUDORA is a trademark of Qualcomm.  
eTrust and InoculateIT are trademarks of Computer Associates Think Inc.  
DIRECTX, EXCHANGE.NET, FRONTPAGE, INTERNET EXPLORER, LINKEXCHANGE,  
MICROSOFT, MICROSOFT EXCHANGE SERVER, MS-DOS, NETMEETING, OUTLOOK,  
POWERPOINT, VISUAL STUDIO, WINDOWS, WINDOWS MEDIA, and WINDOWS NT are  
trademarks of Microsoft Corporation.  
GROUPWISE and NOVELL are trademarks of Novell Inc.  
HITACHI is a trademark of Hitachi Limited.  
LOGITECH is a trademark of Logitech, Inc.  
LUCENT is a trademark of Lucent Technologies, Inc.  
MATRA is a trademark of Matra Hachette.  
MCAFFEE and NETSHIELD are trademarks of McAfee Associates, Inc.  
MYLEX is a trademark of Mylex Corporation.  
NET2PHONE is a trademark of Net2Phone, Inc.  
NETOPIA is a trademark of Netopia, Inc.  
NETSCAPE COMMUNICATOR is a trademark of Netscape Communications Corporation.  
NOTES is a trademark of Lotus Development Corporation.  
NORTON ANTIVIRUS and PCANYWHERE are trademarks of Symantec Corporation.  
POWERQUEST is a trademark of PowerQuest Corporation.  
PROMARK and RHOBOT are trademarks of DMI Promark, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RADISYS is a trademark of Radisys Corporation.  
ROLM is a trademark of Siemens ROLM Communications Inc.  
SLR4, SLR5, and TANDBERG are trademarks of Tandberg Data ASA.  
SONY is a trademark of Sony Corporation.  
SYBASE is a trademark of Sybase, Inc.  
TEAC is a trademark of TEAC Corporation  
UNIX is a trademark of X/Open Company Limited.  
US ROBOTICS, the US ROBOTICS logo, and SPORTSTER are trademarks of US  
Robotics.  
WINAMP is a trademark of Nullsoft, Inc.  
WINRUNNER is a trademark of Mercury Interactive Corporation.  
WINZIP is a trademark of Nico Mark Computing, Inc.  
XEON is a trademark of Intel, Inc.  
Part 2: 703t Server Hardware Installation  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Publication history  
Standard 1.01  
6
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
November 2005  
Publication history  
Publication history  
November 2005  
October 2003  
Standard 1.01 of the CallPilot Installation and  
Configuration, Part 2: 703t Server Hardware  
Installation is issued for general release.  
Standard 1.0 of the CallPilot Installation and  
Configuration, Part 2: 703t Server Hardware  
Installation is issued for general release.  
Part 2: 703t Server Hardware Installation  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Publication history  
Standard 1.01  
8
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Index  
Part 2: 703t Server Hardware Installation  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Standard 1.01  
10  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1  
703t server description  
In this chapter  
Part 2: 703t Server Hardware Installation  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
703t server description  
Standard 1.01  
Server features  
Introduction  
This section provides a general overview of the 703t server.  
Server dimensions  
Height  
chassis only: 42 cm (16.75 in.)  
with chassis feet: 44 cm (17.5 in.)  
Width  
chassis only: 21.5 cm (8.6 in.)  
with chassis feet: 32 cm (12.7 in.)  
Depth (distance from front to  
back)  
65 cm (26 in.)  
Clearance  
front: 25 cm (10 in.)  
rear: 12.5 cm (5 in.)  
side: 7.5 cm (3 in.)  
Note: Additional side clearance  
is required for service.  
top: 7.5 cm (3 in.)  
Weight of fully loaded system  
with  
approximately 22 kg (46 lb)  
two SCSI hard drives  
six populated boards  
CD-ROM drive  
floppy drive  
tape drive  
12  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
November 2005  
703t server description  
Front panel features  
The following diagram shows the 703t server’s front panel features:  
CD-ROM  
Reset button  
drive  
Network LEDs  
CD  
Sleep mode  
button (not used)  
drawer  
eject  
button  
Power button  
Status LEDs  
Tape  
drive  
USB connector  
(not used)  
Air flow  
slots  
Floppy disk  
eject button  
Floppy disk drive  
Hard  
drive  
bays  
Chassis intrusion  
detection switch  
(not used)  
Air flow  
slot  
G101759  
Part 2: 703t Server Hardware Installation  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
703t server description  
Standard 1.01  
The table below describes the parts that are identified in the preceding  
diagram:  
Part  
Function  
Reset button  
Triggers a hardware (cold) reset. Do not use  
this button to perform a server restart. Restart  
the server as described in “Restarting the  
server” in CallPilot Installation and  
Configuration Part 1: Installation and  
Maintenance Overview (555-7101-210).  
Network  
controller LEDs  
(green)  
Left: 10/100Base-T controller LED  
(NIC1 10/100 MB: ELAN  
for Meridian 1/Succession 1000 connection)  
Right: 10/100/1000Base-T controller LED  
(NIC2 1 GB: CLAN  
for Customer LAN connection)  
Sleep mode button  
Power button  
Not used  
Turns the server’s power on or off.  
Status LEDs  
Indicate when the server is powered up and the  
disk drives are active.  
Left: hard drive activity LED (not used)  
Center: power/sleep LED (green)  
Right: status LED (bi-color) indicates  
whether the server is functioning properly,  
or whether a hardware event has occurred.  
USB connector  
For future use  
Floppy disk eject  
button  
Ejects the floppy disk.  
Floppy drive  
Drive for 3-1/2 inch diskettes.  
14  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
November 2005  
703t server description  
Part  
Function  
IDE CD-ROM drive  
(5.25 in.)  
Enables you to use the CallPilot software and  
documentation CD-ROMs.  
CD drive eject  
button  
Opens the CD-ROM drawer. Push the button  
again to close the drawer.  
Backup tape drive  
Hard drive 1  
Hard drive 2  
Drive bay  
Allows backup of hard drive data.  
10,000 rpm hard drive  
10,000 rpm hard drive  
Vacant  
Drive bay  
Vacant  
Drive bay  
Vacant  
Air flow slot  
Must remain empty for proper system cooling.  
Part 2: 703t Server Hardware Installation  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
703t server description  
Standard 1.01  
Rear panel diagram  
The following diagram shows the 703t server’s rear panel features:  
Power connector  
PS/2 mouse connector  
USB connectors  
(not used)  
PS/2 keyboard connector  
Serial port (COM1)  
Parallel port  
Monitor connector  
10/100/1000Base-T  
CLAN Ethernet connector  
(NIC2 1 GB)  
10/100Base-T  
ELAN Ethernet connector  
(NIC1 10/100 MB)  
6
5
4
3
2
1
PCI slots  
Serial port (COM2)  
(not installed)  
G101760  
Note: For more information, see “Slot assignments” on page 19.  
16  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
November 2005  
703t server description  
The table below describes the parts that are identified in the preceding  
diagram:  
Part  
Color  
AC power supply connector  
Not applicable  
(450 W non hot-swap power supply)  
USB connectors  
Not applicable  
Purple  
PS/2 keyboard connector  
PS/2 mouse connector  
Green  
COM1 serial port connector (9-pin)  
Parallel port connector (25-pin)  
Monitor connector (15-pin)  
Teal  
Pink  
Blue  
10/100/1000Base-T CLAN network connector for  
Not applicable  
Customer LAN connection (NIC2 1 GB)  
Note: For more information, see  
10/100Base-T ELAN network connector for  
Meridian 1/Succession 1000 connection  
(NIC1 10/100 MB)  
Not applicable  
Not applicable  
Note: For more information, see  
PCI slots (6)  
Four slots are 100 MHz 3.3 V 64-bit PCI slots.  
Two slots are 33 MHz 5 V 32-bit PCI slots.  
Note: For more information, see  
COM2 serial port connector slot (not installed)  
Teal  
Part 2: 703t Server Hardware Installation  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
703t server description  
Standard 1.01  
Environmental specifications  
Environmental condition  
Specification  
Operating temperature  
10°C to 35°C (50°F to 95°F)  
Maximum rate of change must not  
exceed 10°C (50°F) per hour.  
Non-operating (storage)  
temperature  
-40°C to 70°C (-40°F to 158°F)  
Non-operating humidity  
Altitude  
95%, non-condensing at 30°C (86°F)  
1829 m (6000 ft)  
Electrostatic discharge  
Acoustic noise  
15 kV or more  
50 dBA in a typical office ambient  
temperature (18°C to 25°C  
[64.4°F to 77°F])  
Operating shock  
Handling drop  
No errors with a half sine wave shock  
of 2G (with 1 millisecond duration)  
Operational after a free fall from  
45 cm to 60 cm (18 in. to 24 in.)  
(depending on weight)  
18  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
November 2005  
703t server description  
Slot assignments  
Introduction  
The slot assignment tables show  
the physical location of boards inside the server, relative to other boards  
the order in which boards are installed (for example, board #1, 2, 3, and  
so on)  
how the boards are represented in CallPilot Manager applications (that is,  
on the Maintenance Administration page)  
the maximum capacity for each switch connectivity  
Note: Your server may vary depending on what was ordered from Nortel  
Networks; therefore, your server may not have all of the slots populated.  
Part 2: 703t Server Hardware Installation  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
703t server description  
Standard 1.01  
Slot definition and numbering  
In the following table, the term “slot” refers to the available slot openings in  
the chassis, not the PCI connectors inside the server.  
The slots are numbered from the bottom of the server to the top. Slot 1 is the  
bottom slot in the chassis when the chassis is standing upright.  
CallPilot-assigned  
a
Slot number  
board label  
Not used  
BRD06  
Description  
Not used  
Slot 7  
PCI slot 6  
RAID card  
(full length)  
PCI slot 5  
(full length)  
BRD05  
BRD04  
BRD03  
BRD02  
BRD01  
Not used  
PCI slot 4  
(full length)  
MPB96 board  
Not used  
PCI slot 3  
(full length)  
PCI slot 2  
(full length)  
Not used  
PCI slot 1  
Not used  
(full length)  
a. In CallPilot Manager applications, the CallPilot-assigned board label may  
appear. This label corresponds to the slot number. For example, BRD01 refers to  
the board in slot 1.  
20  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
November 2005  
703t server description  
IRQ mapping table  
The following table lists the assignments for each Interrupt Request (IRQ).  
You do not need this information for installation, but it may be useful for  
troubleshooting.  
Interrupt I/O APIC level Slot or device  
INTR  
IRQ0  
IRQ1  
IRQ2  
INT0  
INT2  
INT1  
Processor interrupt  
Timer (from PIIX4)  
PS/2 keyboard controller  
Internal/reserved  
Not  
applicable  
Note: IRQ2 is actually shared with IRQ9 as a  
cascade interrupt to support IRQs 8–15.  
IRQ3  
IRQ4  
IRQ5  
IRQ6  
IRQ7  
IRQ8  
IRQ9  
IRQ10  
IRQ11  
IRQ12  
IRQ13  
INT3  
INT4  
INT5  
INT6  
INT7  
INT8  
INT9  
INT10  
INT11  
INT12  
INT13  
Onboard serial port B (COM2)  
Onboard serial port A (COM1)  
Available  
Floppy disk drive controller  
Parallel port 1(LPT1)  
Real Time Clock  
Available  
Available  
Available  
PS/2 mouse  
Internal/reserved  
Part 2: 703t Server Hardware Installation  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
703t server description  
Standard 1.01  
Interrupt I/O APIC level Slot or device  
IRQ14  
IRQ15  
INT14  
INT15  
IDE controller  
Available  
22  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
November 2005  
703t server description  
Network connectivity  
Introduction  
This section describes how the 703t server can be integrated into your  
network. The integration depends on the type of switch you are using.  
Refer to:  
ATTENTION  
To secure the CallPilot server from unauthorized access,  
ensure that the CallPilot network is inside your  
organization’s firewall.  
Part 2: 703t Server Hardware Installation  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
703t server description  
Standard 1.01  
Sample network setup: Meridian 1  
The Meridian 1 switch can be one of the following:  
Option 11C or Option 11C Mini using fiber connections  
Option 51C  
Option 61C  
Options 81 and 81C  
The following diagram shows a CallPilot 703t server network setup with a  
Meridian 1 switch.  
Desktop  
client PC  
Desktop  
client PC  
Web-enabled  
administrative  
PC  
Customer LAN (optional)  
Modem  
Meridian1 switch  
CallPilot server  
Router or  
Ethernet  
switch  
MPB board  
MGate  
card  
(optional)  
Embedded LAN  
Laptop  
Web-enabled  
administrative  
PC  
G101626  
24  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
November 2005  
703t server description  
Sample network setup: Succession 1000  
The following diagram shows a CallPilot 703t server network setup with a  
Succession 1000 system:  
Web-enabled  
CallPilot  
administrative  
PC  
Desktop  
client  
PC  
i2004  
Internet  
phonesets  
Telephony LAN/Customer LAN (10/100/1000Base-T)  
Router or  
Ethernet  
switch  
Succession 1000  
Media Gateway  
Expansion  
Internet  
Telephony  
Gateway  
Line Card  
Modem  
(optional)  
CallPilot  
server  
CE-MUX  
DS-30x  
Internet  
Telephony  
Gateway  
Line Card  
Succession  
1000 Media  
Gateway  
Succession  
1000 Call  
Server  
MGate  
card  
MPB board  
Embedded LAN (10/100Base-T)  
Optivity Laptop  
Web-enabled  
CallPilot  
administrative  
PC  
Telephony  
Manager  
PC  
G101636  
Part 2: 703t Server Hardware Installation  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
703t server description  
Standard 1.01  
In the previous diagram, the telephony LAN (TLAN) provides IP  
connectivity between the Succession 1000 system and the i2004 Internet  
phonesets. The connection between the Call Server and Media Gateway can  
be point-to-point, or it can be through the LAN, if the system is installed in a  
distributed data network.  
For information about the Succession 1000 system and i2004 Internet  
phoneset bandwidth and network requirements, refer to the Succession 1000  
Planning and Installation Guide (NTP 553-3023-210).  
Switch connectivity  
For more details about how the 703t server and switch connection is  
established, refer to the switch and server setup document for your switch:  
CallPilot Installation and Configuration Part 3: Succession 1000 System  
and CallPilot Server Configuration (555-7101-510)  
CallPilot Installation and Configuration Part 3: Meridian 1 and  
CallPilot Server Configuration (555-7101-222)  
LAN connectivity  
The 703t server contains two Ethernet controllers on the motherboard that  
provide the following:  
10/100Base-T Ethernet network connectivity to the ELAN  
For information about the ELAN’s purpose and requirements, see “About  
the ELAN” in CallPilot Installation and Configuration Part 1:  
Installation and Maintenance Overview (555-7101-210).  
10/100/1000Base-T Ethernet connectivity to the CLAN  
The CLAN is an optional connection that provides data connectivity  
among desktop and web messaging clients, administrative PCs, and the  
CallPilot server.  
See “Rear panel diagram” on page 16 to identify the location of network  
interface connectors.  
26  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
November 2005  
703t server description  
Network requirements  
Appropriate networking equipment must be available for both the CLAN  
and ELAN.  
The CLAN and ELAN must be properly configured for correct CallPilot  
operation. To ensure correct configuration, Nortel Networks recommends  
that you consult a network specialist.  
ATTENTION  
For important considerations about using the ELAN in  
your network, see About the ELAN” in CallPilot  
Installation and Configuration Part 1: Installation and  
Maintenance Overview (555-7101-210).  
Remote access connectivity  
The RS-232 COM1 connector on the rear of the 703t server provides the  
connection to an external dial-up modem. The modem allows administrators  
and technical support personnel to administer the 703t server from a remote  
location.  
pcAnywhere is used to establish a remote access connection to the server.  
Part 2: 703t Server Hardware Installation  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
703t server description  
Standard 1.01  
Supported peripheral devices  
Introduction  
This section identifies external devices that are supported by the 703t  
server. The following table describes the supported peripheral devices:  
Device  
Description  
Modem  
A 56 Kbps external modem (NTRH9078 in North  
America only) provides remote access to the 703t server.  
The modem connects to the RS-232 COM1 connector on  
the rear of the server.  
Since the modem is an external device, it requires its own  
AC power source referenced to the same ground as the  
703t server and the switch to which it is connected.  
Ethernet hub  
A 10Base-T Ethernet hub provides the ELAN connection  
between the 703t server and the Meridian 1 switch or  
Succession 1000 system. The customer can supply a hub  
from third-party vendors or purchase the 3Com  
10Base-T Ethernet hub (NTRH9017) from Nortel  
Networks.  
Since the hub is an external device, it requires an AC  
power source referenced to the same ground as the 703t  
server and the switch to which it is connected.  
ATTENTION  
If a hub is required or used, it must be located at least 6  
m (20 ft) away from the 703t server. This ensures  
compliance with EMC requirements.  
28  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
November 2005  
703t server description  
Device  
Description  
Monitor, keyboard,  
and mouse  
15-in. monitor: NTRH9011  
Since the monitor is an external device, it requires its  
own AC power source referenced to the same ground  
as the 703t server and the switch to which it is  
connected.  
Keyboard: NTRH9013  
Mouse: NTRH9014  
Part 2: 703t Server Hardware Installation  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
703t server description  
Standard 1.01  
30  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2  
Preinstallation requirements  
In this chapter  
Part 2: 703t Server Hardware Installation  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Preinstallation requirements  
Standard 1.01  
Installation overview  
Introduction  
This section provides an overview of the steps required to install the 703t  
server and peripheral devices. For detailed instructions, see Chapter 3,  
When you are finished, continue with the switch and server setup as  
described in the document for your switch:  
CallPilot Installation and Configuration Part 3: Succession 1000 System  
and CallPilot Server Configuration (555-7101-510)  
CallPilot Installation and Configuration Part 3: Meridian 1 and  
CallPilot Server Configuration (555-7101-222)  
Installation checklist  
Step  
Description  
Check  
1
Ensure that you have reviewed the “Installing CallPilot” section  
in CallPilot Installation and Configuration Part 1: Installation  
and Maintenance Overview (555-7101-210), and completed  
stage 1 of the “Installation checklist.”  
2
Unpack the server, and ensure you have all the items you need  
(see page 35).  
Complete the following checklists that are provided in  
CallPilot Installation and Configuration Part 1: Installation  
and Maintenance Overview (555-7101-210):  
“CallPilot software media and documentation checklist”  
“CallPilot server hardware checklist”  
3
Remove the server cover, and inspect the interior (see pages 37  
32  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
November 2005  
Preinstallation requirements  
Step  
Description  
Check  
4
5
6
7
Replace the server cover.  
Place the 703t server in the chosen location (see page 48).  
Set the DIP switches on the modem (see page 51).  
Connect the 703t server and devices as follows:  
Connect the monitor, keyboard, and mouse (see page 53).  
Connect the modem (see page 55).  
Connect the 703t server to the ELAN hub (see page 57).  
ATTENTION  
If a hub is required or used, it must be located at least 6 m  
(20 ft) away from the 703t server. This ensures compliance  
with EMC requirements.  
Connect the 703t server to the CLAN hub (optional); (see  
page 59).  
ATTENTION  
If a hub is required or used, it must be located at least 6 m  
(20 ft) away from the 703t server. This ensures compliance  
with EMC requirements.  
Install the software feature key adapter (see page 60).  
Connect the power cords for all devices, and then power  
them up (see page 62).  
8
Start the 703t server (see page 64).  
Part 2: 703t Server Hardware Installation  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Preinstallation requirements  
Standard 1.01  
Conventions for warnings  
You may encounter the following types of warnings in this guide. Do not  
ignore them.  
DANGER  
Risk of electric shock  
.
Warns you of an immediate electrical hazard, which, if not  
avoided, will result in shock, serious injury, or death.  
WARNING  
Risk of personal injury  
.
Warns you of a situation in which you can be injured if  
instructions are not followed exactly as stated.  
CAUTION  
Risk of data loss or equipment damage  
.
Alerts you to situations where data can be lost or damaged,  
equipment can be damaged, actions can result in service  
interruption, and productive time can be lost.  
ATTENTION  
Provides information that is essential to the completion  
of a task.  
34  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
November 2005  
Preinstallation requirements  
Unpacking the 703t server  
Introduction  
Follow this procedure to unpack the server and peripherals.  
WARNING  
Risk of personal injury  
.
The 703t CallPilot server weighs approximately 22 kg (46 lb)  
as shipped from manufacturing. If necessary, and to prevent  
personal injury, ask someone to help you unpack and position  
the server.  
To unpack the equipment  
ATTENTION  
As you unpack each item, check it off against the  
packing list, as well as against the following checklists  
provided in CallPilot Installation and Configuration  
Part 1: Installation and Maintenance Overview (555-  
7101-210):  
“CallPilot software media and documentation  
checklist”  
“CallPilot server hardware checklist”  
1 Carefully open the cardboard carton containing the server.  
2 Remove the server from the carton and set it on the floor.  
3 Carefully open the cartons containing the monitor, keyboard, mouse,  
modem, and ELAN hub (if supplied), and set the peripherals aside.  
4 Put all manuals, CD-ROMs, operating system disks, any disks for  
peripherals, and the Windows NT emergency repair disk in a safe place.  
Part 2: 703t Server Hardware Installation  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Preinstallation requirements  
Standard 1.01  
5 Save all packing materials and cartons in case you must return any  
equipment to the carrier.  
What’s next?  
Remove the server cover so that you can inspect the interior of the server.  
36  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
November 2005  
Preinstallation requirements  
Removing the side cover  
Introduction  
This section describes how to remove the server’s side cover so that you can  
work with the interior components. The side cover is on the server’s left side  
when the front of the server is facing you.  
To remove the side panel  
WARNING  
Risk of personal injury  
.
Be careful when you handle the sharp edges of the side panel  
and chassis to prevent personal injury.  
CAUTION  
Risk of equipment damage  
.
Use an ESD wrist strap to protect static-sensitive  
components.  
Place the server on its side to prevent the server from  
accidentally falling over. This provides greater stability. If  
you attempt to work with the server in its standing position,  
it may tip over when you work with the interior  
components.  
Part 2: 703t Server Hardware Installation  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Preinstallation requirements  
Standard 1.01  
The following diagram shows how to remove the side panel. See the  
instructions for removal below.  
1
2
3
G101761  
1 Place the server on its side on your working surface.  
2 Turn the two thumbscrews on the back of the server counter-clockwise to  
loosen them.  
Note: The thumbscrews are not removable.  
Note: If a removable screw is present, remove it. This screw secures the  
cover to the server during shipping.  
3 Place your fingertips in the depression on the side cover, and then as  
you apply pressure, pull the cover approximately 2.5 cm (1 in.) away from  
the front of the server until it stops.  
38  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
November 2005  
Preinstallation requirements  
4 Use one hand to pull the top edge of the cover away from the server to  
disengage the top row of tabs on the cover from the notches in the  
chassis.  
5 Use both hands to lift the cover upward to disengage the bottom row of  
tabs from the notches in the chassis.  
6 Set the cover aside.  
Part 2: 703t Server Hardware Installation  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Preinstallation requirements  
Standard 1.01  
Inspecting the server interior  
Introduction  
Before you install the server, you should perform a visual inspection for  
loose components, foreign matter, or shipping damage inside the server.  
CAUTION  
Risk of equipment damage  
.
When working with interior components, use an ESD wrist  
strap to protect static-sensitive components.  
To inspect the server interior  
1 Ensure that all the cards are fully seated on the baseboard.  
2 Check for any loose wires or foreign objects, such as loose screws,  
inside the chassis.  
3 Review the slot locations (see “Rear panel diagram” on page 16).  
4 Do one of the following:  
IF  
THEN  
you observe  
any damage  
contact your Nortel Networks technical  
support representative.  
components have  
become loose  
secure them. Then replace the server  
cover and proceed with the hardware  
installation.  
Refer to the procedures in CallPilot  
Installation and Configuration Part 5:  
703t Server Maintenance and  
Diagnostics (555-7101-227).  
40  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
November 2005  
Preinstallation requirements  
IF  
THEN  
you are satisfied that the  
replace the server cover.  
703t server has arrived at  
your site undamaged  
Part 2: 703t Server Hardware Installation  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Preinstallation requirements  
Standard 1.01  
Replacing the side cover  
Introduction  
When you are satisfied that the server was not damaged during shipment,  
reinstall the side cover.  
To replace the side cover  
CAUTION  
Risk of equipment damage  
.
Ensure that there are no tools or loose parts inside the server  
chassis before replacing the side cover.  
1 Align the right edge of the server’s side cover with the inside ledge at the  
front of the server.  
2 Ensure that the cover lays flat along the side of the server.  
3 Insert the tabs along the top and bottom edges of the server’s cover  
inside the slots along the top and bottom of the server.  
4 Push the cover towards the front of the server until the tabs firmly  
engage in the chassis.  
Note: When correctly engaged, the cover clicks into place.  
5 Tighten the two thumbscrews on the back of the server.  
42  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
November 2005  
Preinstallation requirements  
The following diagram shows how to: 1) align the tabs, 2) engage the cover  
and 3) tighten the thumbscrews.  
Top and  
bottom tabs  
on cover  
Top and  
bottom slots  
in chassis  
1
2
3
G101762  
What’s next?  
If you want to install the chassis feet on the bottom of the server, continue  
hardware installation. For more information, see “Installation checklist” on  
Part 2: 703t Server Hardware Installation  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Preinstallation requirements  
Standard 1.01  
Installing the chassis feet  
Introduction  
You can install feet on the bottom of the server. The feet stabilize the server  
and will help prevent the server from accidentally falling over on its side.  
To install the chassis feet  
ards  
Tow  
k of  
bac  
ver  
ser  
Tow  
ards  
front of  
serv  
er  
44  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
November 2005  
Preinstallation requirements  
1 Ensure that the server is laying on its side, supported to give the server  
bottom four to five inches clearance above the work surface.  
2 Attach the feet as shown in the preceding diagram.  
Use four screws to attach each foot to the chassis. The holes in the feet  
line up with only one set of holes in the chassis, as follows:  
front foot: The middle hole is towards the front of the chassis.  
back foot: The middle hole is towards the back of the chassis.  
3 Place the server on its feet.  
What’s next?  
Continue with the hardware installation. For more information, see  
Part 2: 703t Server Hardware Installation  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Preinstallation requirements  
Standard 1.01  
46  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3  
Installing the server and  
connecting the peripheral devices  
In this chapter  
Part 2: 703t Server Hardware Installation  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installing the server and connecting the peripheral devices  
Standard 1.01  
Installing the server  
Introduction  
Before you install the 703t server, ensure that the chosen location meets the  
requirements identified on the “Site inspection checklist” provided in  
CallPilot Installation and Configuration Part 1: Installation and  
Maintenance Overview (555-7101-210).  
To install the server  
1 Place the 703t server in its chosen location.  
Note: The server must be placed within 20 m (60 feet) of the Meridian 1  
switch or Succession 1000 system.  
Note: The DS30X cable that connects MPB96 boards to MGate cards is  
20 m (60 feet) long. This allows the server to be placed in a different  
room from the Meridian 1 switch or Succession 1000 system.  
2 Connect peripheral devices as described in the remainder of this  
chapter.  
48  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
November 2005  
Installing the server and connecting the peripheral devices  
Preparing the modem  
Introduction  
You require a modem to support remote dial-up access to the CallPilot  
server. The modem also enables Nortel Networks technical support to  
connect to your CallPilot server for troubleshooting purposes. Nortel  
Networks connects to your server only when you request technical  
assistance.  
Required equipment  
To install the modem, you need the following equipment:  
an analog external modem that includes  
an RJ-11 analog phone cord  
a power adapter cord  
US Robotics 56 Kbps modem (NTRH9078) (North America only)  
a 25-pin male to 9-pin female shielded serial cable for your modem  
(A0841984)  
an analog line jack  
tweezers, or a screwdriver small enough to use to adjust DIP switches  
Modem DIP switches  
Set the modem DIP switches before you connect the modem to the CallPilot  
server.  
Note: This section applies only to the US Robotics 33.6 or 56 Kbps external  
Sportster modem. If your modem is different, refer to the documentation for  
your modem.  
Part 2: 703t Server Hardware Installation  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installing the server and connecting the peripheral devices  
Standard 1.01  
The following diagram shows the key components of the external modem,  
including the location and required settings of the DIP switches:  
RJ-11  
connection  
DIP  
switches  
Serial cable  
(RS-232)  
Power  
connection  
connection  
1
2
3
4
5
6
7
8
Switch positions:  
OFF  
ON  
1 2 3 4 5 6 7 8  
G101445  
50  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
November 2005  
Installing the server and connecting the peripheral devices  
To set the modem DIP switches  
Use a pair of tweezers or a small screwdriver to set the DIP switches as  
described in the “Change to” column of the following table:  
Note: ON is down. OFF is up.  
DIP  
switch  
Default  
setting  
Change  
to  
Function  
1
OFF  
OFF  
Data Terminal Ready (DTR) override  
OFF: Normal DTR operations. (The  
computer must provide a DTR signal for the  
modem to accept commands. If DTR is  
dropped, the call is terminated.)  
ON: The modem ignores DTR (override).  
2
3
4
5
OFF  
ON  
OFF  
ON  
Verbal/numeric result codes  
OFF: Verbal (word) results.  
ON: Numeric results.  
Result code display  
OFF: Suppresses result codes.  
ON: Enables result codes.  
OFF  
ON  
OFF  
ON  
Command mode local echo suppression  
OFF: Displays keyboard commands.  
ON: Suppresses echo.  
Auto answer suppression  
OFF: The modem answers on the first ring  
or later, as specified in user-defined  
nonvolatile memory (NVRAM).  
ON: Disables auto answer.  
Part 2: 703t Server Hardware Installation  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the server and connecting the peripheral devices  
Standard 1.01  
DIP  
switch  
Default  
setting  
Change  
to  
Function  
6
7
8
OFF  
OFF  
ON  
OFF  
OFF  
ON  
Carrier Detect (CD) override  
OFF: The modem sends a CD signal when it  
connects with another modem; it drops the  
CD on disconnect.  
ON: CD is always ON (override).  
Power-on and ATZ reset software defaults  
OFF: Loads Y or Y1 configuration from  
NVRAM.  
ON: Loads &F0-Generic template from  
read-only memory (ROM).  
AT command set recognition  
OFF: Disables command recognition (dumb  
mode).  
ON: Enables recognition (smart mode).  
What’s next?  
52  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
November 2005  
Installing the server and connecting the peripheral devices  
Connecting peripherals to the server  
Introduction  
This section describes how to connect the monitor, keyboard, mouse, and  
modem to the server.  
Rear panel  
The peripheral device connection panel at the back of the server provides a  
legend that shows the symbol for each peripheral device and which  
connector to use.  
CAUTION  
Risk of system failure  
.
You can install or use only Nortel Networks-approved  
peripheral devices on your server. Installation or use of  
unapproved peripheral devices can result in system failure.  
Part 2: 703t Server Hardware Installation  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Installing the server and connecting the peripheral devices  
Standard 1.01  
The diagram below shows the connectors for the power cord and the  
peripheral devices on the 703t server.  
Power connector  
PS/2 mouse connector  
USB connectors  
(not used)  
PS/2 keyboard connector  
Serial port (COM1)  
Parallel port  
Monitor connector  
10/100/1000Base-T  
CLAN Ethernet connector  
(NIC2 1 GB)  
10/100Base-T  
ELAN Ethernet connector  
6
5
4
3
2
1
(NIC1 10/100 MB)  
PCI slots  
Serial port (COM2)  
(not installed)  
G101760  
54  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
November 2005  
Installing the server and connecting the peripheral devices  
To connect the mouse, keyboard, and monitor to the server  
1 Place the monitor, keyboard, and mouse in the same location as the  
server.  
2 Plug the keyboard and mouse into the appropriate PS/2 connectors on  
the chassis rear panel. See the diagram on page 54.  
3 Plug in the monitor connector. Tighten the screws on the connector.  
4 Connect the power cord to the monitor, and plug the other end into a wall  
receptacle or power bar.  
5 Turn on the monitor.  
To connect the modem to the server  
1 Ensure that the modem’s AC power cord is not plugged in.  
2 Connect the large 25-pin male connector to the back of the modem.  
Tighten the connector screws.  
3 Connect the 9-pin female connector to COM1 port at the rear of the  
server. Tighten the connector screws.  
4 Connect one end of the telephone cable to the modem RJ-11 jack  
labeled LINE.  
5 Connect the other end of the telephone cable to the RJ-11 jack in the  
wall.  
6 Connect the power cord to the modem, and plug the other end into a wall  
receptacle or power bar.  
7 Turn on the modem.  
What’s next?  
Part 2: 703t Server Hardware Installation  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Installing the server and connecting the peripheral devices  
Standard 1.01  
Connect the server to the ELAN and CLAN hubs (if applicable).  
IF the server will  
THEN  
be connected to the ELAN  
be connected only to a CLAN  
continue with page 59.  
not be connected to either the  
ELAN or CLAN  
continue with installing the software  
feature key adapter (dongle). See page  
60.  
56  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
November 2005  
Installing the server and connecting the peripheral devices  
Connecting the server to the ELAN  
Introduction  
Connect the CallPilot server to the Meridian 1 switch or Succession 1000  
system using the Embedded LAN (ELAN).  
ATTENTION  
For important considerations about using the ELAN in  
your network, see “About the ELAN” in CallPilot  
Installation and Configuration Part 1: Installation and  
Maintenance Overview (555-7101-210).  
ATTENTION  
If a hub is required or used, it must be located at least 6 m  
(20 ft) away from the 703t server. This ensures compliance  
with EMC requirements.  
To connect the server to the ELAN  
1 Locate the ELAN Ethernet connector on the back of the server.  
Note: The ELAN connector is labeled as NIC1 10/100 MB. For the  
connector location, see the diagram on page 54.  
2 Connect an RJ-45 network cable from the ELAN hub to the server’s  
ELAN connector.  
Note: The ELAN hub is optional if you use a cross-over network cable to  
make a direct point-to-point connection from the server to the switch.  
However, if you choose to establish a direct point-to-point ELAN  
connection, no other device can connect to the ELAN.  
Part 2: 703t Server Hardware Installation  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Installing the server and connecting the peripheral devices  
Standard 1.01  
3 At the switch, connect the ELAN network cable to an MAU (Ethernet)  
transceiver. Then complete the connection from the transceiver to the  
switch.  
DANGER  
Risk of fire hazard  
.
The NTRH9069 MAU is not suitable for installation in ducts,  
plenums, or other spaces used for environmental air. Do  
not install it above a false ceiling or below a raised floor,  
unless it can be confirmed that these spaces are not used  
to convey environmental air.  
What’s next?  
IF the server will  
THEN  
be connected to a CLAN  
not be connected to a CLAN  
continue with installing the software  
feature key adapter (dongle). See page  
60.  
58  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
November 2005  
Installing the server and connecting the peripheral devices  
Connecting the server to the CLAN  
(optional)  
Introduction  
This section provides instructions to connect the server to the Customer  
LAN (CLAN).  
Note: The CLAN connection is optional. However, connection to a CLAN  
is required for support of desktop and web messaging users, or  
administration by means of a web-enabled PC.  
ATTENTION  
If a hub is required or used, it must be located at least 6 m  
(20 ft) away from the 703t server. This ensures compliance  
with EMC requirements.  
To connect the server to the CLAN  
1 Locate the CLAN connector on the back of the server.  
Note: The CLAN connector is labeled as NIC2 1GB. For the connector  
location, see the diagram on page 54.  
2 Connect an RJ-45 network cable from the CLAN hub to the CLAN  
connector.  
What’s next?  
Part 2: 703t Server Hardware Installation  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Installing the server and connecting the peripheral devices  
Standard 1.01  
Installing the Nortel Networks software  
feature key adapter  
Introduction  
The software feature key is a security device that stores the unique serial  
number of the server. The feature key is embedded in the Nortel Networks  
software feature key adapter, which plugs into the parallel port.  
An illustration of the software feature key embedded in the software feature  
key adapter is shown below:  
Software  
feature key  
G101738  
60  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
November 2005  
Installing the server and connecting the peripheral devices  
Requirements  
For installation, you require a Phillips No. 1 screwdriver.  
To install the software feature key adapter  
1 Ensure that there is no cable connected to the parallel port.  
Note: The parallel port is also known as the printer port or LPT1. It is  
located at the back of the server. See the diagram on page 54.  
2 Plug the male end of the adapter into the parallel port.  
3 Tighten the connector screws.  
What’s next?  
Part 2: 703t Server Hardware Installation  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the server and connecting the peripheral devices  
Standard 1.01  
Connecting the server to power  
Before you begin  
Ensure that proper power and grounding are available for all the power  
outlets serving the CallPilot server and its associated peripherals. Power for  
these devices must be wired and fused independently of all other receptacles  
and referenced to the same ground as the PBX system.  
A qualified electrician must implement the single-point ground reference as  
required among the power outlets of the CallPilot server, its associated  
peripherals, and the power outlets of the switch.  
Provide a sufficient number of properly grounded power outlets or power  
bars for all equipment.  
62  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
November 2005  
Installing the server and connecting the peripheral devices  
Before you connect the server to the power source, review the following  
diagram (and the warning that follows) to ensure that all peripheral  
hardware devices are in place:  
CallPilot  
server  
Video  
RJ-45  
RJ-45  
RS-232  
Modem  
Monitor  
Mouse  
Keyboard  
ELAN hub  
(M1 or  
CLAN hub  
(optional)  
Succession  
1000 only)  
AC  
power  
AC  
power  
AC  
power  
AC  
power  
AC  
power  
source  
G101637  
Part 2: 703t Server Hardware Installation  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the server and connecting the peripheral devices  
Standard 1.01  
WARNING  
Risk of personal injury and risk of hardware failure  
.
You must connect the power outlets that are used by the  
CallPilot server and its peripheral devices to the same  
single-point ground reference as the one used by the  
Meridian 1 switch or Succession 1000 system with MGate  
cards connected to the CallPilot server.  
If this requirement is not met, power transients can cause  
personal injury, hardware failure, or both. For more  
information on single-point grounding requirements, refer to  
the discussion of safety guidelines in CallPilot Installation and  
Configuration Part 1: Installation and Maintenance Overview  
(NTP 555-7101-210).  
To connect the server to power  
1 Plug the server’s AC power cord into the server’s rear panel.  
2 Plug the other end into a wall receptacle or power bar.  
To start the server  
1 Press the server’s power switch to start the server.  
2 Observe the Power-On Self-Test (POST) and initialization messages on  
the monitor.  
3 When the following menu appears on the monitor, choose the first option  
to start Windows NT:  
OS Loader V4.00  
Please select the operating system to start:  
Windows NT Server Version 4.00  
Windows NT Server Version 4.00 [VGA mode]  
64  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
November 2005  
Installing the server and connecting the peripheral devices  
Use <arrow up> and <arrow down> to move the highlight  
to your choice  
Press Enter to choose  
Seconds until highlighted choice will be started  
automatically 5  
The Windows NT startup sequence begins.  
4 Ensure that the Windows NT logon window appears on the monitor.  
Note: If the Windows NT logon window does not appear, refer to  
CallPilot Installation and Configuration Part 5: 703t Server Maintenance  
and Diagnostics (555-7101-227) for troubleshooting instructions.  
What’s next?  
If Windows NT started successfully, proceed with switch and server setup as  
described in the document for your switch:  
CallPilot Installation and Configuration Part 3: Succession 1000 System  
and CallPilot Server Configuration (555-7101-510)  
CallPilot Installation and Configuration Part 3: Meridian 1 and  
CallPilot Server Configuration (555-7101-222)  
Part 2: 703t Server Hardware Installation  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the server and connecting the peripheral devices  
Standard 1.01  
66  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
Numerics  
A
703t server  
CLAN  
adapter, software feature key 60  
connection, establishing 59  
connector 17  
connections  
B
board labels, CallPilot Manager 20  
establishing 62  
power 62  
dimensions 12  
ELAN  
C
connection, establishing 5758  
environmental specifications 18  
feet, installing 4445  
front panel, description 1315  
hard drive bays 15  
installing 48  
interior inspection 4041  
IRQ assignments 21  
LEDs 14  
checklist, installation 3233  
CLAN  
connecting server to 59  
server connector 17  
COM1 connection, description 27  
connectivity  
CLAN 26  
ELAN 26  
remote access 27  
PCI slots 17  
peripheral device connections, diagram  
Customer LAN See CLAN  
peripheral devices, connecting 53  
power connection, establishing 64  
rear panel, description 5354  
side cover  
D
DC power input 55  
devices, peripheral 28  
keyboard 29  
removing 3739  
replacing 4243  
modem 28  
monitor 29  
slot assignments 20  
slot locations 16  
mouse 28, 29  
starting 64  
unpacking 35  
diagrams  
CallPilot network connections  
Meridian 1 24  
Part 2: 703t Server Hardware Installation  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Index  
Succession 1000 25  
Standard 1.01  
K
front panel 13  
modem 50  
rear panel 16, 54  
server connections, peripheral devices 62  
server feet, installing 44  
side cover  
keyboard  
connecting to the server 55  
description 29  
removing 38  
replacing 43  
L
LAN connections, description 2627  
LEDs  
software feature key adapter 60  
TLAN (Succession 1000) 25  
dimensions, 703t server 12  
DIP switches, setting modem 5152  
dongle 60  
network controller 14  
system status 14  
M
E
Meridian 1, CallPilot server network setup  
ELAN  
modem 28  
connecting server to 5758  
Embedded LAN See ELAN  
environmental specifications, 703t server 18  
Ethernet hub 28  
connecting to the server 55  
description 28  
diagram 50  
DIP switches, description 4950  
DIP switches, setting 5152  
required equipment 49  
monitor  
F
fax modem  
connecting to the server 55  
description 29  
diagram 50  
required equipment 49  
front panel, description 1315  
mouse  
connecting to the server 55  
description 28, 29  
H
N
hard drive bays 15  
network  
controllers 2627  
protocols 2627  
setup, CallPilot  
Meridian 1 24  
Succession 1000 25  
I
interior, inspecting server 4041  
IRQ assignments, 703t server 21  
68  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
November 2005  
Index  
installing 48  
P
interior inspection 40, 4041  
IRQ assignments 21  
LEDs 14  
part numbers  
keyboard 29  
modem 28  
monitor 29  
PCI slots 17  
peripheral device connections, diagram  
peripheral devices, connecting 53  
power connection establishing 64  
rear panel, description 5354  
serial number 60  
mouse 28, 29  
PCI slots 17  
peripheral devices 28  
connecting to the server 53  
keyboard 29  
modem 28  
monitor 29  
side cover  
removing 3739  
mouse 28, 29  
replacing 4243  
power  
slot assignments 20  
slot locations 16  
connecting server to 64  
grounding, requirement 64  
protocols, supported network 2627  
starting 64  
unpacking 35  
side cover  
removing 3739  
replacing 4243  
R
single-point grounding, power requirement  
rear panel, description 1617, 5354  
remote access connectivity 27  
RS-232 connection 27  
slot assignments 20  
slot locations 16  
software feature key 60  
software feature key adapter  
description 60  
S
installing 61  
serial number 60  
server  
specifications, environmental 18  
Succession 1000, CallPilot network setup 25  
switches, setting modem DIP 5152  
CLAN  
connection, establishing 59  
connector 17  
connections  
T
establishing 62  
power 62  
dimensions 12  
ELAN  
telephony LAN See TLAN  
TLAN, diagram 25  
connection, establishing 5758  
environmental specifications 18  
feet, installing 4445  
front panel, description 1315  
hard drive bays 15  
U
unpacking 35  
Part 2: 703t Server Hardware Installation  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
Standard 1.01  
W
warnings, conventions 34  
70  
CallPilot  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CallPilot  
Installation and Configuration  
Part 2: 703t Server Hardware Installation  
Copyright © 2003 Nortel Networks. All Rights Reserved.  
Information is subject to change without notice. Nortel Networks reserves the right to make  
changes in design or components as progress in engineering and manufacturing may  
warrant.  
The process of transmitting data and call messaging between the CallPilot server and the  
switch or system is proprietary to Nortel Networks. Any other use of the data and the  
transmission process is a violation of the user license unless specifically authorized in  
writing by Nortel Networks prior to such use. Violations of the license by alternative usage of  
any portion of this process or the related hardware constitutes grounds for an immediate  
termination of the license and Nortel Networks reserves the right to seek all allowable  
remedies for such breach.  
Publication number:  
Product release:  
Document release:  
Date:  
555-7101-226  
2.02  
Standard 1.01  
November 2005  
Printed in Canada  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Refrigerator KFN 12943 SD edt cs User Manual
Multi Tech Systems Network Card MTA128NT User Manual
Musical Fidelity Stereo Amplifier X AS100 User Manual
National Instruments Network Card NI PXIe 1065 User Manual
NETGEAR Network Router R6300 100NAS User Manual
NeumannBerlin Microphone KMS 84 i User Manual
NordicTrack Home Gym NTL109050 User Manual
Optoma Technology Projector TS725 User Manual
Panasonic Fax Machine KX FL503HK User Manual
Panasonic Projector LB1EA User Manual