| Important Information   Warranty   The NI PXIe-1065 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced   by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the   warranty period. This warranty includes parts and labor.   The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in   materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments   will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects   during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free.   A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before any   equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are covered by   warranty.   National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical accuracy. In   the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent editions of this document   without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected. In no event shall National   Instruments be liable for any damages arising out of or related to this document or the information contained in it.   EXCEPT AS SPECIFIED HEREIN, NATIONAL INSTRUMENTS MAKES NO WARRANTIES, EXPRESS OR IMPLIED, AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF   MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. CUSTOMER’S RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF NATIONAL   INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER. NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR DAMAGES RESULTING   FROM LOSS OF DATA, PROFITS, USE OF PRODUCTS, OR INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED OF THE POSSIBILITY THEREOF. This limitation of   the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including negligence. Any action against   National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in   performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service   failures caused by owner’s failure to follow the National Instruments installation, operation, or maintenance instructions; owner’s modification of the   product; owner’s abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside   reasonable control.   Copyright   Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying,   recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National   Instruments Corporation.   National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other   intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only   to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.   Trademarks   National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section   on ni.com/legal for more information about National Instruments trademarks.   Other product and company names mentioned herein are trademarks or trade names of their respective companies.   Members of the National Instruments Alliance Partner Program are business entities independent from National Instruments and have no agency,   partnership, or joint-venture relationship with National Instruments.   Patents   For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software,   the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents.   WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS   (1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF   RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN   ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT   INJURY TO A HUMAN.   (2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE   IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY,   COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS   AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND HARDWARE   COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL DEVICES,   TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR MISUSES, OR   ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE HEREAFTER   COLLECTIVELY TERMED “SYSTEM FAILURES”). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD CREATE A RISK OF   HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD NOT BE RELIANT SOLELY   UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID DAMAGE, INJURY, OR DEATH,   THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO PROTECT AGAINST SYSTEM FAILURES,   INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS. BECAUSE EACH END-USER SYSTEM IS   CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION   DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT   EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY   RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER   NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT   LIMITATION, THE APPROPRIATE DESIGN, PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.   Download from Www.Somanuals.com. All Manuals Search And Download.   About This Manual   Chapter 1   Getting Started   Unpacking......................................................................................................................1-1   Optional Equipment.......................................................................................................1-5   Rack Mount Kit...............................................................................................1-5   PXI Express Peripheral Slots...........................................................................1-8   System Timing Slot.........................................................................................1-8   PXI Trigger Bus ..............................................................................................1-10   PXIe_SYNC_CTRL........................................................................................1-14   Chapter 2   Providing Adequate Clearance........................................................................2-2   Setting Fan Speed............................................................................................2-5   Installing Filler Panels.....................................................................................2-5   Installing Slot Blockers ...................................................................................2-5   Rack Mounting ..............................................................................................................2-5   Connecting Safety Ground.............................................................................................2-5   Connecting to Power Source..........................................................................................2-6   © National Instruments Corporation   v NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Contents   Installing a PXI Express System Controller.................................................................. 2-6   Power Inhibit Switch LED Indicator............................................................................. 2-10   Inhibit Mode Switch...................................................................................................... 2-12   PXI_CLK10 Rear Connectors....................................................................................... 2-12   PXI Express System Configuration with MAX ............................................................ 2-12   Trigger Configuration in MAX....................................................................... 2-14   Chapter 3   Replacing the Modular Power Supply........................................................................... 3-3   Removal .......................................................................................................... 3-3   Configuration .................................................................................................. 3-4   Connecting Safety Ground.............................................................................. 3-4   Connecting to Power Source........................................................................... 3-4   Appendix A   Specifications   Appendix B   Pinouts   Technical Support and Professional Services   Glossary   Index   NI PXIe-1065 User Manual   vi   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   About This Manual   The NI PXIe-1065 User Manual describes the features of the NI PXIe-1065   chassis and contains information about configuring the chassis, installing   the modules, and operating the chassis.   Conventions   The following conventions are used in this manual:   » The » symbol leads you through nested menu items and dialog box options   to a final action. The sequence File»Page Setup»Options directs you to   pull down the File menu, select the Page Setup item, and select Options   from the last dialog box.   This icon denotes a note, which alerts you to important information.   This icon denotes a caution, which advises you of precautions to take to   avoid injury, data loss, or a system crash. When this symbol is marked on   the product, refer to the Read Me First: Safety and Radio-Frequency   Interference document, shipped with the product, for precautions to take.   bold   Bold text denotes items that you must select or click in the software, such   as menu items and dialog box options. Bold text also denotes parameter   names.   italic   Italic text denotes variables, emphasis, a cross-reference, or an introduction   to a key concept. Italic text also denotes text that is a placeholder for a word   or value that you must supply.   monospace   Text in this font denotes text or characters that you should enter from the   keyboard, sections of code, programming examples, and syntax examples.   This font is also used for the proper names of disk drives, paths, directories,   programs, subprograms, subroutines, device names, functions, operations,   variables, filenames, and extensions.   © National Instruments Corporation   vii   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   About This Manual   Related Documentation   The following documents contain information that you might find helpful   as you read this manual:   • IEEE 1101.1-1991, IEEE Standard for Mechanical Core   Specifications for Microcomputers Using IEC 603-2 Connectors   • IEEE 1101.10, IEEE Standard for Additional Mechanical   Specifications for Microcomputers Using IEEE 1101.1 Equipment   Practice   • • • PICMG EXP.0 R1.0 CompactPCI Express Specification,   PCI Industrial Computers Manufacturers Group   PCI Express Base Specification, Revision 1.1, PCI Special Interest   Group   PXI-5 PXI Express Hardware Specification, Revision 1.0,   PXI Systems Alliance   NI PXIe-1065 User Manual   viii   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   1 Getting Started   This chapter describes the key features of the NI PXIe-1065 chassis and   lists the kit contents and optional equipment you can order from National   Instruments.   Unpacking   Carefully inspect the shipping container and the chassis for damage. Check   for visible damage to the metal work. Check to make sure all handles,   hardware, and switches are undamaged. Inspect the inner chassis for any   possible damage, debris, or detached components. If damage appears to   have been caused during shipment, file a claim with the carrier. Retain the   packing material for possible inspection and/or reshipment.   What You Need to Get Started   The NI PXIe-1065 chassis kit contains the following items:   ❑ NI PXIe-1065 chassis   ❑ Filler panels   ❑ AC power cable—refer to Table 1-1 for AC power cables   ❑ NI PXIe-1065 User Manual   ❑ Software media with PXI Platform Services 2.0 or higher   ❑ Read Me First: Safety and Radio-Frequency Interference   ❑ Chassis number labels   © National Instruments Corporation   1-1   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 1   Getting Started   Table 1-1. AC Power Cables   Reference Standards   Power Cable   Standard 120 V (USA)   Switzerland 220 V   ANSI C73.11/NEMA 5-15-P/IEC83   SEV   Australia 240 V   AS C112   Universal Euro 230 V   North America 120 V   United Kingdom 230 V   CEE (7), II, IV, VII IEC83   ANSI C73.20/NEMA 5-15-P/IEC83   BS 1363/IEC83   If you are missing any of the items listed in Table 1-1, or if you have the   incorrect AC power cable, contact National Instruments.   Key Features   The NI PXIe-1065 chassis combines a high-performance 18-slot   PXI Express backplane with a high-output power supply and a structural   design that has been optimized for maximum usability in a wide range   of applications. The chassis’ modular design ensures a high level of   maintainability, resulting in a very low mean time to repair (MTTR).   The NI PXIe-1065 chassis fully complies with the PXI-5 PXI Express   Hardware Specification, offering advanced timing and synchronization   features.   The key features of the NI PXIe-1065 chassis include the following:   High Performance for Instrumentation Requirements   • Up to 1 GB/s (single direction) per PXI Express slot dedicated   bandwidth (x4 PCIe)   • • 30 W per slot cooling meets increased PXIe cooling requirements   Low-jitter internal 10 MHz reference clock for PXI slots with   25 ppm stability   • Low-jitter internal 100 MHz reference clock for PXIe slots with   25 ppm stability   Quiet operation for 0 to 30 °C at 43.6 dBA   NI PXIe-1065 User Manual   1-2   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 1   Getting Started   • • • Variable speed fan controller optimizes cooling and acoustic emissions   Remote power-inhibit control   Complies with PXI and CompactPCI Specifications   High Reliability   • • • • 0 to 55 °C extended temperature range   Power supply, temperature, and fan monitoring   HALT tested for increased reliability   Field replaceable power supply shuttle   Multi-Chassis Support   • • • PXIe System Timing Slot for tight synchronization across chassis   Rear CLK10 I/O connectors   Switchless CLK10 routing   Optional Features   • • • • • Front and rear rack-mount kits   Replacement power supply shuttle   EMC filler panels   Slot blockers for improved cooling performance   Factory installation services   © National Instruments Corporation   1-3   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 1   Getting Started   Chassis Description   Figures 1-1 and 1-2 show the key features of the NI PXIe-1065 chassis   front and back panels. Figure 1-1 shows the front view of the   NI PXIe-1065. Figure 1-2 shows the rear view of the NI PXIe-1065.   2 3 4 NI PXIe-1065   5 1 13   H 1 2 3 4 5 6 7 8 9 10   11 H   12 H   13 H   14   15   16   17   18   12   5 10   6 8 9 8 7 6 11   1 2 3 4 5 6 7 Chassis Carry Handle   Backplane Connectors   PXI Filler Panels   Chassis Model Name   Removable Feet   PXI Peripheral Slots (9x)   PXI Express System Timing Slot   8 9 PXI Express Hybrid Peripheral Slots (4x)   PXI Express Peripheral Slots (3x)   10 PXI Express System Controller Slot   11 Power Inhibit Switch   12 Power Inhibit Switch LED   13 System Controller Expansion Slots   Figure 1-1. Front View of the NI PXIe-1065 Chassis   NI PXIe-1065 User Manual   1-4   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 1   Getting Started   6 7 3 4 5 4 8 9 10   2 1 11   12   13   4 4 14   1 2 3 4 5 6 7 Universal AC Input   8 Remote Inhibit and Voltage Monitoring Connector   Inhibit Mode Selector Switch   Push-Reset Circuit Breaker   Chassis Ground Screw   Fan Guard Retainer Screws   Power Supply Shuttle ID Label   10 MHz REF OUT BNC   10 MHz REF IN BNC   9 10 Fan Speed Selector Switch   11 Power Supply Shuttle Mounting Screws (10x)   12 Power Supply Shuttle Handle (2x)   13 Power Supply Shuttle   14 Fan Guard   Figure 1-2. Rear View of the NI PXIe-1065 Chassis   Optional Equipment   Contact National Instruments to order the following options for the   NI PXIe-1065 chassis.   EMC Filler Panels   Optional EMC filler panel kits are available from National Instruments.   There are two optional kits for mounting the PXIe-1065 chassis into a rack.   The first option is a pair of mounting brackets for use on the front of the   chassis. The second option is a rear rack mount kit. The rear rack mount kit   differs from the front kit to allow for easier installation into the rack.   For more information, refer to Figure A-3, NI Chassis Rack Mount Kit   Components.   © National Instruments Corporation   1-5   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 1   Getting Started   Slot Blockers   Optional slot blocker kits are available from National Instruments for   improved thermal performance when all slots are not used.   NI PXIe-1065 Chassis Backplane Overview   This section provides an overview of the backplane features for the   NI PXIe-1065 chassis.   Interoperability with CompactPCI   The design of the NI PXIe-1065 provides you the flexibility to use the   following devices in a single PXI Express chassis:   • • • • • PXI Express compatible products   CompactPCI Express compatible 4-Link system controller products   CompactPCI Express compatible Type-2 peripheral products   PXI peripheral products   Standard CompactPCI peripheral products   System Controller Slot   The system controller slot is Slot 1 of the chassis and is a 4-Link   configuration system slot as defined by the CompactPCI Express and   PXI Express specifications. It has three system controller expansion slots   for system controller modules that are wider than one slot. These slots   allow the system controller to expand to the left to prevent the system   controller from using peripheral slots.   The backplane routes a x4 PCI Express link from the system controller   slot to slots 7 and 8, and a x1 PCI Express link to a PCI Express to PCI   Translation Bridge on the backplane. The PCI Express to PCI Translation   Bridge on the backplane provides a 32-bit/33MHz PCI bus to slots 2 to 7.   The second PCI Translation Bridge provides PCI bus to slots 11, 12, 13, 15,   16, 17, and 18 (not to slot 14).   A x4 link goes to the PXI Express switch and the PCI Express connectivity   of slots 9 to 14 is connected through the switch.   The system controller slot also has connectivity to some PXI features such   as: PXI_CLK10, PXI Star, PXI Trigger Bus and PXI Local Bus 6.   NI PXIe-1065 User Manual   1-6   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 1   Getting Started   By default, the system controller will control the power supply with the   PS_ON# signals. A logic low on this line will turn the power supply on.   Note The Inhibit Mode switch on the rear of the chassis must be in the Default position   for the system controller to have control of the power supply. Refer to the Inhibit Mode   Switch section of Chapter 2, Installation and Configuration, for details about the Inhibit   Mode switch.   Hybrid Peripheral Slots   The chassis provides four hybrid peripheral slots as defined by the PXI-5   PXI Express Hardware Specification: slot 7 and slots 11–13. A hybrid   peripheral slot can accept the following peripheral modules:   • • • A PXI Express Peripheral with x4 or x1 PCI Express link to the system   slot or through a switch to the system slot.   A CompactPCI Express Type-2 Peripheral with x4 or x1 PCI Express   link to the system slot or through a switch to the system slot.   A hybrid-compatible PXI Peripheral module that has been modified by   replacing the J2 connector with an XJ4 connector installed in the upper   eight rows of J2. Refer to the PXI Express Specification for details. The   PXI Peripheral communicates through the backplane’s 32-bit PCI bus.   • A CompactPCI 32-bit peripheral on the backplane’s 32-bit PCI bus.   The hybrid peripheral slots provide full PXI Express functionality and   32-bit PXI functionality except for PXI Local Bus. The hybrid peripheral   slot only connects to PXI Local Bus 6 left and right.   PXI Peripheral Slots   There are nine PXI peripheral slots which will accept PXI or CompactPCI   peripherals: slots 2–6 and slots 15–18. These slots are on the backplane’s   32-bit PCI busses. These slots offer full PXI functionality, but have no   PXI Express features. The 64-bit PCI signals on the P2 connectors are not   connected.   © National Instruments Corporation   1-7   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 1   Getting Started   PXI Express Peripheral Slots   There are three PXI Express peripheral slots: slots 8–10. Slot 8 is directly   connected to the system slot with a x4 PCI Express link. Slots 9 and 10 are   connected to the system slot through a PCI Express switch. PXI Express   peripheral slots can accept the following modules:   • A PXI Express Peripheral with x4 or x1 PCI Express link to the system   slot or through a switch to the system slot.   • A CompactPCI Express Type-2 Peripheral with x4 or x1 PCI Express   link to the system slot or through a switch to the system slot.   System Timing Slot   The System Timing Slot is slot 14. The system timing slot will accept the   following peripheral modules:   • • • A PXI Express System Timing Module with x4 or x1 PCI Express link   to the system slot through a PCIe switch.   A PXI Express Peripheral with x4 or x1 PCI Express link to the system   slot through a PCIe switch.   A CompactPCI Express Type-2 Peripheral with x4 or x1 PCI Express   link to the system slot through a PCIe switch.   The system timing slot has 3 dedicated differential pairs (PXIe_DSTAR)   connected from the TP1 and TP2 connectors to the XP3 connector for each   the XP3 connector of the system timing slot as shown in Figure 1-3. The   PXIe_DSTAR pairs can be used for high-speed triggering, synchronization   and clocking. Refer to the PXI Express Specification for details.   The system timing slot also has a single-ended (PXI Star) trigger connected   to every slot. Refer to Figure 1-3 for details.   The system timing slot has a pin (PXI_CLK10_IN) through which a system   timing module may source a 10MHz clock to which the backplane will   phase-lock. Refer to the System Reference Clock section for details.   The system timing slot has a pin (PXIe_SYNC_CTRL) through which a   system timing module can control the PXIe_SYNC100 timing. Refer to the   PXI Express Specification and the PXIe_SYNC_CTRL section of this   chapter for details.   NI PXIe-1065 User Manual   1-8   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 1   Getting Started   PXI STAR 16   PXI STAR 14   PXI STAR 15   PXI STAR 12   PXI STAR 13   PX DSTAR 10   PX STAR 11   PXI STAR 8   PXI STAR 4   PXI STAR 2   PXI STAR 0   PXI STAR 1   PXI STAR 9   PXI STAR 7   PXI STAR 6   PXI STAR 3   PXI STAR 5   8 10   H H 2 4 11 H 12 H 13   14   15   16   17   18   5 6 7 1 PXIe_DSTAR 1   PXIe_DSTAR 2   PXIe_DSTAR 3   PXIe_DSTAR 4   PXIe_DSTAR 5   PXIe_DSTAR 6   PXI Local Bus   peripheral slot with adjacent peripheral slots to the left and right, as shown   in Figure 1-4.   The backplane routes the full 13-line PXI Local Bus between adjacent PXI   slots (slots 2–6 and 15–18) and PXI Local Bus 6 between all other slots.   Refer to Figure 1-4 for details. The left local bus 6 from slot 1 is not routed   anywhere and the right local bus signals from slot 18 are not routed   anywhere.   © National Instruments Corporation   1-9   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 1   Getting Started   Local bus signals may range from high-speed TTL signals to analog signals   as high as 42 V.   Initialization software uses the configuration information specific to each   adjacent peripheral module to evaluate local bus compatibility.   PXI   PXI   Trigger Bus   Buffer Bridge   Trigger Bus   Buffer Bridge   PXI Trigger Bus Segment 2   PXI Trigger Bus Segment 3   PXI Trigger Bus Segment 1   8 10   H H 2 4 11 H 12 H 13   14   15   16   17   18   5 6 7 1 Figure 1-4. PXI Trigger Bus and Local Bus Connectivity Diagram   PXI Trigger Bus   All slots on the same PXI bus segment share eight PXI trigger lines. You   can use these trigger lines in a variety of ways. For example, you can use   triggers to synchronize the operation of several different PXI peripheral   modules. In other applications, one module located in the system timing   slot can control carefully timed sequences of operations performed on other   modules in the system. Modules can pass triggers to one another, allowing   precisely timed responses to asynchronous external events the system is   monitoring or controlling.   The PXI trigger lines from adjacent PXI trigger bus segments can be routed   in either direction across the PXI trigger bridges through buffers. This   allows you to send trigger signals to, and receive trigger signals from, every   slot in the chassis. Static trigger routing (user-specified line and directional   NI PXIe-1065 User Manual   1-10   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 1   Getting Started   assignments) can be configured through Measurement & Automation   Explorer (MAX). Dynamic routing of triggers (automatic line assignments)   is supported through certain National Instruments drivers like NI-DAQmx.   Note Although any trigger line may be routed in either direction, it cannot be routed in   more than one direction at a time.   System Reference Clock   The PXIe-1065 chassis supplies the PXI 10 MHz system clock signal   PXIe_CLK100 and PXIe_SYNC100 to the PXI Express slots, hybrid slots,   and system timing slot.   An independent buffer (having a source impedance matched to the   backplane and a skew of less than 1 ns between slots) drives PXI_CLK10   to each peripheral slot. Refer to Figure 1-5 for the routing configuration of   PXI_CLK10. You can use this common reference clock signal to   synchronize multiple modules in a measurement or control system.   An independent buffer drives PXIe_CLK100 to the PXI Express peripheral   slots, hybrid peripheral slots, and system timing slot. Refer to Figure 1-5   for the routing configuration of PXIe_CLK100. These clocks are matched   in skew to less than 100 ps. The differential pair must be terminated on the   so that when there is no peripheral or a peripheral that does not connect to   PXIe_CLK100, there is no clock being driven on the pair to that slot.   An independent buffer drives PXIe_SYNC100 to the PXI Express   peripheral slots, hybrid peripheral slots, and system timing slot. Refer   to Figure 1-5 for the routing configuration of PXIe_SYNC100. The   differential pair must be terminated on the peripheral with LVPECL   termination for the buffer to drive PXIe_SYNC100 so that when there is   no peripheral or a peripheral that does not connect to PXIe_SYNC100,   there is no SYNC100 signal being driven on the pair to that slot.   © National Instruments Corporation   1-11   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 1   Getting Started   10 MHz   REF IN   10 MHz   REF OUT   PXI_CLK10_IN   PXI_CLK10   8 10   H H 2 4 11 H 12 H 13   14   15   16   17   18   5 6 7 1 Figure 1-5. Distribution of PXI_CLK10, PXIe_CLK100, and PXIe_SYNC100   PXI_CLK10, PXIe_CLK100 and PXIe_SYNC100 have the default timing   relationship described in Figure 1-6.   0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 PXIe_CLK100   PXI_CLK10   PXIe_SYNC100   Figure 1-6. System Reference Clock Default Behavior   To synchronize the system to an external clock, you can drive PXI_CLK10   from an external source through the PXI_CLK10_IN pin on the System   Timing Slot, for the pinout. When a 10MHz clock is detected on this pin,   the backplane automatically phase-locks the PXI_CLK10, PXIe_CLK100,   and PXIe_SYNC100 signals to this external clock and distributes these   NI PXIe-1065 User Manual   1-12   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 1   Getting Started   signals to the slots (refer to Figure 1-5 for the distribution of PXI_CLK10,   PXIe_CLK100 and PXIe_SYNC100). Refer to Appendix A,   Specifications, for the specification information for an external clock   rear of the chassis. When a 10MHz clock is detected on this connector, the   backplane automatically phase-locks the PXI_CLK10, PXIe_CLK100, and   PXIe_SYNC100 signals to this external clock and distributes these signals   to the slots (refer to Figure 1-5 for the distribution of PXI_CLK10,   PXIe_CLK100 and PXIe_SYNC100). Refer to Appendix A,   Specifications, for the specification information for an external clock   provided on the 10 MHz REF IN connector on the rear panel of the chassis.   If the 10 MHz clock is present on both the PXI_CLK10_IN pin of the   System Timing Slot and the 10 MHz REF IN connector on the rear of the   chassis, the signal on the System Timing Slot is selected. Refer to Table 1-2   which explains how the 10 MHz clocks are selected by the backplane.   Table 1-2. Backplane External Clock Input Truth Table   System Timing Slot   PXI_CLK10_IN   Rear Chassis Panel   10 MHz REF IN   Backplane PXI_CLK10, PXIe_CLK100   and PXIe_SYNC100   No clock present   No clock present   No clock present   Backplane generates its own clocks   10 MHz clock present   PXI_CLK10, PXIe_CLK100 and   PXIe_SYNC100 all phase-locked to Rear   Chassis Panel—10 MHz REF IN   10 MHz clock present   10 MHz clock present   No clock present   PXI_CLK10, PXIe_CLK100 and   PXIe_SYNC100 all phase-locked to   System Timing Slot— PXI_CLK10_IN   10 MHz clock present   PXIe_SYNC100 all phase-locked to   System Timing Slot—PXI_CLK10__IN   A copy of the backplane’s PXI_CLK10 is exported to the 10 MHz REF   OUT connector on the rear of the chassis. This clock is driven by an   independent buffer. Refer to Appendix A, Specifications, for the   specification information for the 10 MHz REF OUT signal on the rear   panel of the chassis.   © National Instruments Corporation   1-13   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 1   Getting Started   PXIe_SYNC_CTRL   PXIe_SYNC100 is by default a 10 ns pulse synchronous to PXI_CLK10.   The frequency of PXIe_SYNC100 is 10/n MHz, where n is a positive   integer. The default for n is 1, giving PXIe_SYNC100 a 100 ns period.   be set to any positive integer from 1 to 255.   The system timing slot has a control pin for PXIe_SYNC100 called   PXIe_SYNC_CTRL for use when n > 1. Refer to Table B-7, XP3   Connector Pinout for the System Timing Slot, for system timing slot pinout.   Refer to Appendix A, Specifications, for the PXIe_SYNC_CTRL input   specifications.   By default, a high-level detected by the backplane on the   PXIe_SYNC_CTRL pin causes a synchronous restart for the   PXIe_SYNC100 signal. On the next PXI_CLK10 edge the   PXIe_SYNC100 signal will restart. This will allow several chassis to have   their PXIe_SYNC100 in phase with each other. Refer to Figure 1-7 for   timing details with this method.   PXI_CLK10   PXIe_SYNC_CTRL   PXIe_SYNC100   SYNC100 Divider   Restarted Here   Figure 1-7. PXIe_SYNC100 at 3.33 MHz Using PXIe_SYNC_CTRL as Restart   NI PXIe-1065 User Manual   1-14   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   2 Installation and Configuration   This chapter describes how to prepare and operate the NI PXIe-1065   chassis.   Before connecting the chassis to a power source, read this chapter and   the Read Me First: Safety and Radio-Frequency Interference document   included with your kit.   Safety Information   Caution Before undertaking any troubleshooting, maintenance, or exploratory procedure,   carefully read the following caution notices.   This equipment contains voltage hazardous to human life and safety, and   is capable of inflicting personal injury.   • Chassis Grounding—The chassis requires a connection from the   premise wire safety ground to the chassis ground. The earth safety   ground must be connected during use of this equipment to minimize   shock hazards. Refer to the Connecting Safety Ground section for   instructions on connecting safety ground.   • Live Circuits—Operating personnel and service personnel must not   remove protective covers when operating or servicing the chassis.   Adjustments and service to internal components must be undertaken   by qualified service technicians. During service of this product,   the mains connector to the premise wiring must be disconnected.   Dangerous voltages may be present under certain conditions;   use extreme caution.   • Explosive Atmosphere—Do not operate the chassis in conditions   where flammable gases are present. Under such conditions, this   equipment is unsafe and may ignite the gases or gas fumes.   © National Instruments Corporation   2-1   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 2   Installation and Configuration   • Part Replacement—Only service this equipment with parts that are   exact replacements, both electrically and mechanically. Contact   National Instruments for replacement part information. Installation of   parts with those that are not direct replacements may cause harm to   personnel operating the chassis. Furthermore, damage or fire may   occur if replacement parts are unsuitable.   • Modification—Do not modify any part of the chassis from its original   condition. Unsuitable modifications may result in safety hazards.   Chassis Cooling Considerations   The NI PXIe-1065 chassis is designed to operate on a bench or in an   instrument rack. Regardless of the configuration you must provide the   cooling clearances as outlined in the following sections.   Providing Adequate Clearance   intake and exhaust vents are located along the sides of the chassis.   Adequate clearance between the chassis and surrounding equipment or   blockages must be maintained to ensure proper cooling of the chassis   power supply as well as the modules plugged into the chassis. These   clearances are outlined in Figure 2-1. The vent locations for the   NI PXIe-1065 chassis are shown in Figure 2-2. Failure to provide these   clearances may result in thermal-related failures in the chassis or modules.   NI PXIe-1065 User Manual   2-2   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 2   Installation and Configuration   Dimensions are in inches (millimeters)   1.75   (44.45)   1.75   (44.45)   NI PXIe-1065   H 1 2 3 4 5 6 7 8 9 10   11 H   12 H   13 H   14   15   16   17   18   3.00   (76.20)   Figure 2-1. NI PXIe-1065 Cooling Clearances   © National Instruments Corporation   2-3   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 2   Installation and Configuration   2 1 3 1 2 Primary Air Exhaust Vent   Primary Air Intake Vent   3 Secondary Air Intake/Exhaust Vents   (both sides)   Figure 2-2. NI PXIe-1065 Vents   Chassis Ambient Temperature Definition   The chassis fan control system uses intake air temperature as the input for   controlling fan speeds when in Auto Fan Speed mode. Because of this, the   chassis ambient temperature is defined as the temperature that exists just   outside of the fan intake vents on the rear of the chassis. Note that this   temperature may be higher than ambient room temperature depending   on the surrounding equipment and/or blockages present. It is the user’s   responsibility to ensure that this ambient temperature does not exceed the   NI PXIe-1065 User Manual   2-4   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 2   Installation and Configuration   rated ambient temperature as stated in Appendix A, Specifications. If the   temperature exceeds the stated spec the power switch LED will blink green,   chapter.   Setting Fan Speed   The fan-speed selector switch is on the rear panel of the NI PXIe-1065   chassis. Refer to Figure 1-2, Rear View of the NI PXIe-1065 Chassis, to   locate the fan-speed selector switch. Select High for maximum cooling   performance or Auto for improved acoustic performance. When set to   Auto, the fan speed is determined by chassis intake air temperature.   Installing Filler Panels   To maintain proper module cooling performance, install filler panels   (provided with the chassis) in unused or empty slots. Secure with the   captive mounting screws provided.   Installing Slot Blockers   The cooling performance of the chassis can be improved by installing   optional slot blockers. Refer to ni.com for more details.   Rack Mounting   Rack mount applications require the optional rack mount kits available   from National Instruments. Refer to the instructions supplied with the rack   mount kits to install your NI PXIe-1065 chassis in an instrument rack.   Refer to Figure A-3, NI Chassis Rack Mount Kit Components.   Note You may want to remove the feet from the NI PXIe-1065 chassis when rack   mounting. To do so, remove the screws holding the feet in place.   Connecting Safety Ground   Caution The NI PXIe-1065 chassis are designed with a three-position NEMA 5-15 style   plug for the U.S. that connects the ground line to the chassis ground. To minimize shock   hazard, make sure the electrical power outlet you use to power the chassis has an   appropriate earth safety ground.   © National Instruments Corporation   2-5   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 2   If your power outlet does not have an appropriate ground connection, you   must connect the premise safety ground to the chassis grounding screw   located on the rear panel. Refer to Figure 1-2, Rear View of the   NI PXIe-1065 Chassis, to locate the chassis grounding screw. To connect   the safety ground, complete the following steps:   1. Connect a 16 AWG (1.3 mm) wire to the chassis grounding screw   using a grounding lug. The wire must have green insulation with a   yellow stripe or must be noninsulated (bare).   2. Attach the opposite end of the wire to permanent earth ground using   toothed washers or a toothed lug.   Connecting to Power Source   To completely remove power, you must disconnect the AC power cable.   Attach input power through the rear AC inlet using the appropriate   AC power cable supplied. Refer to Figure 1-2, Rear View of the   NI PXIe-1065 Chassis, to locate the AC inlet.   The Inhibit Mode switch allows you to power on the chassis or place it in   standby mode. Set the Inhibit Mode switch on the back of the chassis to the   Manual position. Observe that all fans become operational and the power   switch LED is a steady green. Switching the Inhibit Mode switch to the   Default position allows the system controller to control the power supply.   Installing a PXI Express System Controller   This section contains general installation instructions for installing a   PXI Express system controller in a NI PXIe-1065 chassis. Refer to your   PXI Express system controller user manual for specific instructions and   warnings. To install a system controller, complete the following steps:   1. Connect the AC power source to the PXI Express chassis before   installing the system controller. The AC power cord grounds the   chassis and protects it from electrical damage while you install the   system controller.   2. Install the system controller into the system controller slot (slot 1,   indicated by the red card guides) by first placing the system controller   PCB into the front of the card guides (top and bottom). Slide the   NI PXIe-1065 User Manual   2-6   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 2   Installation and Configuration   system controller to the rear of the chassis, making sure that the   injector/ejector handle is pushed down as shown in Figure 2-3.   4 1 3 2 1 2 NI PXI Express System Controller   NI PXIe-1065 Chassis   3 4 Injector/Ejector Handle   System Controller Front Panel Mounting Screws (4x)   Figure 2-3. Installing a PXIe System Controller   3. When you begin to feel resistance, pull up on the injector/ejector   handle to seat the system controller fully into the chassis frame. Secure   the system controller front panel to the chassis using the system   controller front-panel mounting screws.   4. Connect the keyboard, mouse, and monitor to the appropriate   connectors. Connect devices to ports as required by your system   configuration.   5. Power on the chassis. Verify that the system controller boots. If the   system controller does not boot, refer to your system controller user   manual.   © National Instruments Corporation   2-7   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 2   Installation and Configuration   Figure 2-4 shows a PXI Express system controller installed in the system   controller slot of a NI PXIe-1065 chassis. You can place CompactPCI,   CompactPCI Express, PXI, or PXI Express modules in other slots   depending on the slot type.   1 2 3 1 NI PXIe-1065 Chassis   2 NI PXIe System Controller   3 Injector/Ejector Rail   Figure 2-4. NI PXI Express System Controller Installed in a NI PXIe-1065 Chassis   Caution The NI PXIe-1065 chassis has been designed to accept a variety of peripheral   module types in different slots. To prevent damage to the chassis, ensure that the peripheral   Started, for a description of the various slot types.   NI PXIe-1065 User Manual   2-8   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 2   Installation and Configuration   This section contains general installation instructions for installing a   peripheral module in a NI PXIe-1065 chassis. Refer to your peripheral   module user manual for specific instructions and warnings. To install a   module, complete the following steps:   1. Connect the AC power source to the PXI Express chassis before   protects it from electrical damage while you install the module.   2. Ensure that the chassis is powered off.   3. Install a module into a chassis slot by first placing the module card   PCB into the front of the card guides (top and bottom), as shown in   Figure 2-5. Slide the module to the rear of the chassis, making sure that   the injector/ejector handle is pushed down as shown in Figure 2-5.   4. When you begin to feel resistance, push up on the injector/ejector   handle to fully seat the module into the chassis frame. Secure the   module front panel to the chassis using the module front-panel   mounting screws.   3 2 NI   PXIe-106   5 1 6 4 5 1 2 3 Peripheral Module Front Panel Mounting Screws (2x)   NI PXI Express System Controller   NI PXIe-1065 Chassis   4 5 6 Injector/Ejector Rail   Injector/Ejector Handle   PXI Peripheral Module   Figure 2-5. Installing PXI, PXI Express, or CompactPCI Peripheral Modules   © National Instruments Corporation   2-9   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 2   Installation and Configuration   Power Inhibit Switch LED Indicator   The chassis power inhibit switch has an integrated LED. This LED   indicates one of four different conditions:   • • • • If the inhibit switch LED is steady green (not flashing), the chassis is   powered on and operating normally.   If the inhibit switch LED is flashing green, the air-intake temperature   has exceeded the chassis operating range.   If the inhibit switch LED is flashing red, the power supply outputs are   not within voltage regulation requirements.   If the inhibit switch LED is steady red, the system fans or power supply   fan has failed. The remaining fans will automatically be driven high.   Note If two system fans or both of the power supply fans fail the chassis will shut down   automatically, preventing the chassis and modules from damage due to overheating.   Remote Voltage Monitoring and Control   The NI PXIe-1065 chassis supports remote voltage monitoring and   inhibiting through a female 9-pin D-SUB (DB-9) connector located on   the rear panel. Table 2-1 shows the pinout of the 9-pin D-SUB (DB-9)   connector.   Table 2-1. Remote Inhibit and Voltage Monitoring Connector Pinout   DB-9 Pin   Signal   Logic Ground   +5 VDC   1 2 3 4 5 6 7 Reserved   +3.3 VDC   Inhibit (Active Low)   +12 VDC   Reserved   NI PXIe-1065 User Manual   2-10   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 2   Installation and Configuration   Table 2-1. Remote Inhibit and Voltage Monitoring Connector Pinout (Continued)   DB-9 Pin   Signal   –12 VDC   8 9 Logic Ground   6 7 8 9 1 2 3 4 5 connector, be careful not to short the probe leads together. Doing so could damage the   power supply.   You can use a digital voltmeter to ensure all voltage levels in the   NI PXIe-1065 chassis are within the allowable limits. Referring to   Table 2-2, connect one lead of the voltmeter to a supply pin on the remote   voltage monitoring connector (9-pin D-SUB) on the rear panel. Refer to   Table 2-1 for a pinout diagram of the remote voltage monitoring connector.   Connect the reference lead of the voltmeter to one of the ground pins.   Compare each voltage reading to the values listed in Table 2-2.   Note Use the rear-panel 9-pin D-SUB connector to check voltages only. Do not use the   connector to supply power to external devices.   Table 2-2. Power Supply Voltages at Voltage Monitoring Connector (DB-9)   Pin   2 Supply   +5 V   Acceptable Voltage Range   4.75 to 5.25 V   3.135 to 3.465 V   11.4 to 12.6 V   –12.6 to –11.4 V   0 V   4 +3.3 V   6 +12 V   8 –12 V   1, 9   Logic Ground   If the voltages fall within the specified ranges, the chassis complies with the   CompactPCI voltage-limit specifications.   © National Instruments Corporation   2-11   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 2   Installation and Configuration   Inhibit Mode Switch   On the rear panel of the chassis there is an Inhibit Mode switch. Refer to   Figure 1-2, Rear View of the NI PXIe-1065 Chassis, for the location. The   Inhibit Mode switch is recessed to prevent it from accidentally being   switched.   The Inhibit Mode switch should be in the Default position when normal   power inhibit switch functionality is desired. If the user needs to power on   a chassis without a system controller installed the switch should be in the   Manual position.   When the Inhibit Mode switch is set to the Manual position, the power   supplies are enabled, and you can use the Inhibit signal (active low) on   pin 5 of the Remote Inhibit and Voltage Monitoring connector to power off   the chassis. To remotely power off the chassis, connect the Inhibit pin   (pin 5) to a Logic Ground pin (pin 1 or 9). As long as this connection exists,   the chassis will remain off (standby); when you remove this connection, the   chassis turns on.   Note For the Remote Inhibit signal to control the On/Off (standby) state of the chassis,   the Inhibit Mode switch must be in the Manual position.   PXI_CLK10 Rear Connectors   There are two BNC connectors on the rear of the NI PXIe-1065 chassis for   PXI_CLK10. The connectors are labeled IN and OUT. You can use them   for supplying the backplane with PXI_CLK10 or routing the backplane’s   PXI_CLK10 to another chassis. Refer to the System Reference Clock   section of Chapter 1, Getting Started, for details about these signals.   PXI Express System Configuration with MAX   The PXI Platform Services software included with your chassis   automatically identifies your PXI Express system components to generate   a pxiesys.ini file. You can configure your entire PXI system and   identify PXI-1 chassis through Measurement & Automation Explorer   (MAX), included with your system controller. MAX creates the   parameters. MAX also provides an interface to route and reserve triggers   so dynamic routing, through drivers such as DAQmx, avoids   NI PXIe-1065 User Manual   2-12   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 2   Installation and Configuration   double-driving and potentially damaging trigger lines. For more   information about routing and reserving PXI triggers, refer to   KnowledgeBase 3TJDOND8 at ni.com/support.   The configuration steps for single or multiple-chassis systems are the same.   Figure 2-6. Multichassis Configuration in MAX   PXI-1 System Configuration   1. Launch MAX.   2. In the Configuration tree, click the Devices and Interfaces branch to   expand it.   3. If the PXI system controller has not yet been configured, it is labeled   PXI System (Unidentified). Right-click this entry to display the   pop-up menu, then select the appropriate system controller model from   the Identify As submenu.   © National Instruments Corporation   2-13   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 2   Installation and Configuration   4. Click the PXI system controller. The chassis (or multiple chassis, in a   multichassis configuration) is listed below it. Identify each chassis by   right-clicking its entry, then selecting the appropriate chassis model   through the Identify As submenu. Further expanding the PXI System   branch shows all devices in the system that can be recognized by   NI-VISA. When your system controller and all your chassis are   identified, the required pxisys.ini file is complete.   The PXI specification allows for many combinations of PXI chassis and   system modules. To assist system integrators, the manufacturers of   PXI chassis and system modules must document the capabilities of their   products. PXI Express devices must provide a driver and .ini file for   identification. These files are provided as part of the PXI Platform Services   software included with your system controller. The minimum   documentation requirements for PXI-1 are contained in .ini files, which   consist of ASCII text. System integrators, configuration utilities, and   device drivers can use these .ini files.   The capability documentation for a PXI-1 chassis is contained in a   chassis.ini file provided by the chassis manufacturer. The information   in this file is combined with information about the system controller to   create a single PXI-1 system initialization file called pxisys.ini   (PXI System Initialization). The NI system controller uses MAX to   generate the pxisys.ini file from the chassis.ini file.   Device drivers and other utility software read the pxiesys.ini and   pxisys.ini file to obtain system information. For detailed information   Trigger Configuration in MAX   Each chassis has one or more trigger buses, each with eight lines   numbered 0 through 7 that can be reserved and routed statically or   dynamically. Static reservation pre-allocates a trigger line to prevent its   configuration by a user program. Dynamic reservation/routing/deallocation   is on the fly within a user program based upon National Instruments APIs   such as NI-DAQmx. Static reservation of trigger lines can be implemented   by the user in MAX through the Triggers tab. Reserved trigger lines will   not be used by PXI modules dynamically configured by programs such as   NI-DAQmx. This prevents the instruments from double-driving the trigger   lines, possibly damaging devices in the chassis. In the default   configuration, trigger lines on each bus are independent. For example,   if trigger line 3 is asserted on trigger bus 0, by default it will not be   automatically asserted on any other trigger bus.   NI PXIe-1065 User Manual   2-14   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 2   Installation and Configuration   Complete the following steps to reserve these trigger lines in MAX.   1. In the Configuration tree, click on the PXI chassis branch you want to   configure.   2. Then, in the right-hand pane, toward the bottom, click on the   Triggers tab.   3. Select which trigger lines you would like to statically reserve.   4. Click the Apply button.   PXI Trigger Bus Routing   Some National Instruments chassis, such as the PXI-1065 and the   PXI-1044/1045, have the capability to route triggers from one bus to others   within the same chassis using the Trigger Routing tab in MAX, as shown   in Figure 2-6.   Note Selecting any non-disabled routing automatically reserves the line in all trigger   buses being routed to. If you are using NI-DAQmx, it will reserve and route trigger lines   for you, so you won’t have to route trigger lines manually.   Complete the following steps to configure trigger routings in MAX.   1. In the Configuration tree, select the chassis in which you want to   route trigger lines.   2. In the right-hand pane, select the Trigger Routing tab near the bottom.   3. For each trigger line, select Route Right, Route Outward From   Middle, or Route Left to route triggers on that line in the described   direction, or select Disabled for the default behavior with no manual   routing.   4. Click the Apply button.   © National Instruments Corporation   2-15   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 2   Installation and Configuration   Using System Configuration and Initialization Files   The PXI Express specification allows many combinations of PXI Express   chassis and system modules. To assist system integrators, the   manufacturers of PXI Express chassis and system modules must document   the capabilities of their products. The minimum documentation   requirements are contained in .ini files, which consist of ASCII text.   System integrators, configuration utilities, and device drivers can use these   .ini files.   The capability documentation for the NI PXIe-1065 chassis is contained in   the chassis.ini file on the software media that comes with the chassis.   The information in this file is combined with information about the system   controller to create a single system initialization file called pxisys.ini   (PXI System Initialization). The system controller manufacturer either   provides a pxisys.ini file for the particular chassis model that contains   the system controller or provides a utility that can read an arbitrary   chassis.ini file and generate the corresponding pxisys.ini file.   System controllers from NI provide the pxisys.ini file for the   NI PXIe-1065 chassis, so you should not need to use the chassis.ini   file. Refer to the documentation provided with the system controller or   to ni.com/support for more information on pxisys.ini and   chassis.ini files.   Device drivers and other utility software read the pxisys.ini file to   obtain system information. The device drivers should have no need to   directly read the chassis.ini file. For detailed information regarding   initialization files, refer to the PXI Express specification at   NI PXIe-1065 User Manual   2-16   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   3 Maintenance   This chapter describes basic maintenance procedures you can perform on   the NI PXIe-1065 chassis.   Caution Disconnect the power cable prior to servicing a NI PXIe-1065 chassis.   Service Interval   Clean dust from the chassis exterior (and interior) as needed, based on the   operating environment. Periodic cleaning increases reliability.   Preparation   The information in this section is designed for use by qualified service   personnel. Read the Read Me First: Safety and Radio-Frequency   Interference document included with your kit before attempting any   procedures in this chapter.   Caution Many components within the chassis are susceptible to static discharge damage.   Service the chassis only in a static-free environment. Observe standard handling   precautions for static-sensitive devices while servicing the chassis. Always wear a   grounded wrist strap or equivalent while servicing the chassis.   Cleaning   Cleaning procedures consist of exterior and interior cleaning of the chassis.   Refer to your module user documentation for information on cleaning the   individual CompactPCI or PXI Express modules.   Caution Always disconnect the AC power cable before cleaning or servicing the chassis.   Interior Cleaning   Use a dry, low-velocity stream of air to clean the interior of the chassis.   Use a soft-bristle brush for cleaning around components.   © National Instruments Corporation   3-1   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 3   Maintenance   Exterior Cleaning   Clean the exterior surfaces of the chassis with a dry lint-free cloth or a   soft-bristle brush. If any dirt remains, wipe with a cloth moistened in a mild   soap solution. Remove any soap residue by wiping with a cloth moistened   with clear water. Do not use abrasive compounds on any part of the chassis.   Caution Avoid getting moisture inside the chassis during exterior cleaning, especially   through the top vents. Use just enough moisture to dampen the cloth.   Do not wash the front- or rear-panel connectors or switches. Cover these components while   cleaning the chassis.   Do not use harsh chemical cleaning agents; they may damage the chassis. Avoid chemicals   that contain benzene, toluene, xylene, acetone, or similar solvents.   Resetting the AC Mains Circuit Breaker   If the NI PXIe-1065 chassis is connected to an AC source and encounters   an over-current condition, the circuit breaker on the rear panel will trip to   prevent damage to the chassis. Complete the following steps to reset the   circuit breaker.   1. Turn off the chassis.   2. Disconnect the AC power cable.   3. Depress the circuit breaker to reset it.   4. Reconnect the AC power cable.   5. Turn on the chassis.   1. Turn off the chassis.   2. Disconnect the AC power cable.   3. Remove all modules from the chassis.   4. Complete the procedure described in the Connecting to Power Source   section of Chapter 2, Installation and Configuration. If the power   switch LED is not a steady green, contact National Instruments.   5. Verify that the NI PXIe-1065 chassis can meet the power requirements   of your CompactPCI or PXI Express modules. Overloading the chassis   can cause the breaker to trip. Refer to Appendix A, Specifications.   NI PXIe-1065 User Manual   3-2   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 3   Maintenance   6. The over-current condition that caused the circuit breaker to trip   may be due to a faulty CompactPCI or PXI Express module. Refer to   the documentation supplied with the modules for troubleshooting   information.   Replacing the Modular Power Supply   This section describes how to remove, configure, and install the AC   power supply shuttle in the NI PXIe-1065 chassis.   Cautions Disconnect the power cable prior to replacing the power supply.   Do not attempt to use a power supply shuttle from another chassis such as the   NI PXI-1044/1045. Doing so may damage your chassis and the power supply shuttle.   Before connecting the power supply shuttle to a power source, read this   section and the Read Me First: Safety and Radio-Frequency Interference   document included with the kit.   Removal   The NI PXIe-1065 AC power supply is a replacement part for the   NI PXIe-1065 AC chassis. Before attempting to replace the power supply   shuttle, verify that there is adequate clearance behind the chassis.   Disconnect the power cable from the power supply shuttle on the back of   the chassis. Identify the ten mounting screws for the NI PXIe-1065 that   attach the power supply shuttle to the chassis. Refer to Figure 1-2, Rear   View of the NI PXIe-1065 Chassis, for the screw locations. Using a Phillips   screwdriver, remove the screws. Pull on the two rear handles of the power   supply shuttle to remove it from the back of the chassis.   Installation   Ensure that there is no visible damage to the new power supply shuttle.   Verify that the housing and connector on the new power supply shuttle   have no foreign material inside. Remove the protective cap on the   PXI_CLK10 connector. Install the new power supply shuttle into the   opening on the rear of the chassis. Replace and tighten the ten screws with   a Phillips screwdriver.   © National Instruments Corporation   3-3   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Chapter 3   Maintenance   Configuration   The fan-speed selector switch is on the rear panel of the power supply   shuttle. Refer to Figure 1-2, Rear View of the NI PXIe-1065 Chassis,   Mode switch to the Default position.   Connecting Safety Ground   and Configuration.   Connecting to Power Source   Refer to the Connecting to Power Source section of Chapter 2, Installation   and Configuration.   NI PXIe-1065 User Manual   3-4   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   A Specifications   This appendix contains specifications for the NI PXIe-1065 chassis.   Caution Specifications are subject to change without notice.   Electrical   AC Input   Input voltage range................................. 100 to 240 VAC   Operating voltage range1........................ 90 to 264 VAC   Input frequency ...................................... 50/60 Hz   Operating frequency range1 ................... 47 to 63 Hz   Input current rating................................. 10–5 A   Over-current protection.......................... 12 A circuit breaker   Line regulation   3.3 V................................................ < 0.2%   5 V................................................... < 0.1%   12 V .............................................. < 0.1%   Efficiency............................................... 70% typical   Power disconnect ....................................The AC power cable provides   main power disconnect. The   front-panel power switch causes   the internal chassis power supply   to provide DC power to the   CompactPCI/PXI Express   backplane. You also can use the   rear-panel D-SUB 9-pin connector   and power mode switch to control   the internal chassis power supply.   1 The operating range is guaranteed by design.   © National Instruments Corporation   A-1   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix A   Specifications   DC Output   DC current capacity (IMP   ) Voltage   +3.3 V   Maximum Current   61 A   56 A   45 A   4 A   +5 V   +12 V   –12 V   5 VAUX   1.5 A   Note Maximum combined +3.3 V, +5 V, and +12 V power is 699 W.   Maximum total power is 701.5 W.   The maximum power dissipated in the system slot should not exceed 140 W.   Backplane pin current capacity   Slot   +5 V   9 A   V (I/O) +3.3 V   +12 V   11 A   2 A   –12 V   0 A   5 VAUX   1 A   System Controller Slot   System Timing Slot   0 A   0 A   5 A   9 A   3 A   6 A   0 A   6 A   0 A   1 A   Hybrid Peripheral Slot with   PXI-1 Peripheral   1 A   1 A   0 A   Hybrid Peripheral Slot with   PXI-5 Peripheral   0 A   6 A   0 A   3 A   6 A   3 A   1 A   0 A   1 A   1 A   0 A   PXI-1 Peripheral Slot   11 A   Load regulation   Voltage   Load Regulation   +3.3 V   +12 V   +5 V   <5%   <5%   <5%   <5%   –12 V   NI PXIe-1065 User Manual   A-2   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix A   Specifications   Maximum ripple and noise (20 MHz bandwidth)   Voltage   +3.3 V   +12 V   +5 V   Maximum Ripple and Noise   50 mVpp   120 mVpp   50 mVpp   –12 V   120 mVpp   Over-current protection.......................... All outputs protected from short   circuit and overload with   automatic recovery   Over-voltage protection   3.3 V and 5 V.................................. Clamped at 20 to 30% above   nominal output voltage   Power supply shuttle MTTR.................. Replacement in under 5 minutes   Chassis Cooling   Module cooling system   NI PXIe-1065.................................. Forced air circulation   (positive pressurization) through   three 165 cfm fans with   High/Auto speed selector   Slot airflow direction ............................. Bottom of module to top of   module   Module cooling intake ........................... Bottom rear of chassis   Module cooling exhaust......................... Along both sides and top of   chassis   Power supply cooling system................. Forced air circulation through   two integrated fans   Power supply cooling intake.................. Right side of chassis   Power supply cooling exhaust................ Left side of chassis   © National Instruments Corporation   A-3   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix A   Specifications   Environmental   Maximum altitude...................................2,000 m (800 mbar)   (at 25 °C ambient)   Pollution Degree.....................................2   For indoor use only.   Operating Environment   Ambient temperature range ....................0 to 55 °C   (Tested in accordance with   IEC-60068-2-1 and   IEC-60068-2-2. Meets   MIL-PRF-28800F Class 3   low temperature limit and   MIL-PRF-28800F Class 2   high temperature limit.)   Relative humidity range..........................10 to 90%, noncondensing   (Tested in accordance with   IEC-60068-2-56.)   Storage Environment   Ambient temperature range ....................–40 to 71 °C   (Tested in accordance with   IEC-60068-2-1 and   IEC-60068-2-2. Meets   MIL-PRF-28800F Class 3 limits.)   Relative humidity range..........................5 to 95%, noncondensing   (Tested in accordance with   IEC-60068-2-56.)   Shock and Vibration   Operational shock...................................30 g peak, half-sine, 11 ms pulse   (Tested in accordance with   IEC-60068-2-27. Meets   MIL-PRF-28800F Class 2 limits.)   Random Vibration ..................................5 to 500 Hz, 0.3 grms   NI PXIe-1065 User Manual   A-4   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix A   Specifications   Acoustic Emissions   Sound Pressure Level (at Operator Position)   (Tested in accordance with ISO 7779. Meets MIL-PRF-28800F   requirements.)   Auto fan (up to ~30 °C ambient) ........... 45.0 dBA   High fan.................................................. 63.3 dBA   Sound Power   Auto fan (up to ~30 °C ambient) ........... 55.5 dBA   High fan.................................................. 76.2 dBA   Note Specifications are subject to change without notice.   Safety   This product is designed to meet the requirements of the following   standards of safety for electrical equipment for measurement, control,   • • IEC 61010-1, EN 61010-1   UL 61010-1, CSA 61010-1   Note For UL and other safety certifications, refer to the product label or the Online   Product Certification section.   Electromagnetic Compatibility   This product is designed to meet the requirements of the following   standards of EMC for electrical equipment for measurement, control,   and laboratory use:   • • • • EN 61326 (IEC 61326): Class A emissions; Basic immunity   EN 55011 (CISPR 11): Group 1, Class A emissions   AS/NZS CISPR 11: Group 1, Class A emissions   FCC 47 CFR Part 15B: Class A emissions   ICES-001: Class A emissions   Note For the standards applied to assess the EMC of this product, refer to the Online   Product Certification section.   © National Instruments Corporation   A-5   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix A   Specifications   Note For EMC compliance, operate this device with shielded cabling.   CE Compliance   This product meets the essential requirements of applicable European   Directives as follows:   • • 2006/95/EC; Low-Voltage Directive (safety)   2004/108/EC; Electromagnetic Compatibility Directive (EMC)   Online Product Certification   Refer to the product Declaration of Conformity (DoC) for additional   regulatory compliance information. To obtain product certifications and the   DoC for this product, visit ni.com/certification, search by model   number or product line, and click the appropriate link in the Certification   column.   Environmental Management   National Instruments is committed to designing and manufacturing   products in an environmentally responsible manner. NI recognizes that   eliminating certain hazardous substances from our products is beneficial   not only to the environment but also to NI customers.   For additional environmental information, refer to the NI and the   Environment Web page at ni.com/environment. This page contains the   environmental regulations and directives with which NI complies, as well   as other environmental information not included in this document.   Waste Electrical and Electronic Equipment (WEEE)   EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling   center. For more information about WEEE recycling centers and National Instruments   WEEE initiatives, visit ni.com/environment/weee.htm.   ⬉ᄤֵᙃѻક∵ᶧ ࠊㅵ⧚ ࡲ⊩ ˄Ё ˅ RoHS   Ёᅶ᠋   ݇Ѣ   ヺড়Ё⬉ᄤֵᙃѻકЁ䰤 ࠊՓ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ DŽ National Instruments   National Instruments   (RoHS)   Ё   ড়㾘ᗻֵᙃˈ䇋ⱏᔩ ni.com/environment/rohs_chinaDŽ   RoHS   ni.com/environment/rohs_china   (For information about China RoHS compliance, go to   .)   NI PXIe-1065 User Manual   A-6   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix A   Specifications   Backplane   Size......................................................... 3U-sized; one system slot   (with three system expansion   slots) and 17 peripheral slots.   Compliant with IEEE 1101.10   mechanical packaging.   PXI Express Specification   compliant.   Accepts both PXI Express and   CompactPCI (PICMG 2.0 R 3.0)   3U modules.   Backplane bare-board material .............. UL 94 V-0 Recognized   Backplane connectors ............................ Conforms to IEC 917 and   IEC 1076-4-101, and are   UL 94 V-0 rated   System Synchronization Clocks (PXI_CLK10, PXIe_CLK100,   PXIe_SYNC100)   10 MHz System Reference Clock: PXI_CLK10   Maximum slot-to-slot skew ................... 1 ns   Accuracy ................................................ 25 ppm max. (guaranteed over   the operating temperature range)   Maximum jitter ...................................... 5 ps RMS phase-jitter   (10 Hz–1 MHz range)   Duty-factor............................................. 45%–55%   Unloaded signal swing........................... 3.3 V 0.3 V   Note For other specifications refer to the PXI-1 Hardware Specification.   100 MHz System Reference Clock: PXIe_CLK100 and   PXIe_SYNC100   Maximum slot-to-slot skew ................... 100 ps   Accuracy ................................................ 25 ppm max. (guaranteed over   the operating temperature range)   © National Instruments Corporation   A-7   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix A   Specifications   Maximum jitter.......................................3 ps RMS phase-jitter   (10 Hz–12 kHz range)   2 ps RMS phase-jitter   (12 kHz–20 MHz range)   Duty-factor for PXIe_CLK100...............45%–55%   Absolute single-ended voltage swing   (When each line in the differential pair   has 50 W termination to 1.30 V   or Thévenin equivalent)..........................400–1000 mV   Note For other specifications refer to the PXI-5 PXI Express Hardware Specification.   External 10 MHz Reference Out (BNC on rear panel of   chassis)   Accuracy................................................. 25 ppm max. (guaranteed over   the operating temperature range)   Maximum jitter.......................................5 ps RMS phase-jitter   (10 Hz–1 MHz range)   Output amplitude ....................................1 VPP 20% square-wave   into 50 Ω   2 VPP unloaded   Output impedance...................................50 Ω 5 Ω   External Clock Source   Frequency ...............................................10 MHz 100 PPM   Input amplitude   Rear panel BNC...............................200 mVPP to 5 VPP square-wave   or sine-wave   System timing slot   PXI_CLK10_IN ..............................5 V or 3.3 V TTL signal   Rear panel BNC input impedance ..........50 Ω 5 Ω   Maximum jitter introduced   by backplane...........................................1 ps RMS phase-jitter   (10 Hz–1 MHz range)   NI PXIe-1065 User Manual   A-8   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix A   Specifications   PXIe_SYNC_CTRL   VIH.......................................................... 2.0–5.5 V   VIL .......................................................... 0–0.8 V   Maximum slot-to-slot skew ................... 250 ps   Backplane characteristic impedance ...... 65 Ω 10%   Note For PXI slot to PXI Star mapping refer to the System Timing Slot section of   Chapter 1, Getting Started.   For other specifications refer to the PXI-1 Hardware Specification.   PXI Differential Star Triggers (PXIe-DSTARA,   PXIe-DSTARB, PXIe-DSTARC)   Maximum slot-to-slot skew ................... 150 ps   Maximum differential skew................... 25 ps   Backplane differential impedance.......... 100 Ω 10%   Note For PXIe slot to PXI_DSTAR mapping refer to the System Timing Slot section   of Chapter 1, Getting Started.   For other specifications, the NI PXIe-1065 complies with the PXI-5 PXI Express   Hardware Specification.   Mechanical   Overall dimensions   Standard chassis   Height ...................................... 6.97 in. (177.1 mm)   Width ....................................... 18.30 in. (464.8 mm)   Depth ....................................... 18.40 in. (467.4 mm)   feet extended on table top, height is increased approximately 2.08 in. (52.8 mm) in front   and 0.583 in. (14.8 mm) in rear.   © National Instruments Corporation   A-9   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix A   Specifications   Weight ....................................................12.8 kg (28.2 lb)   Chassis materials ....................................Sheet Aluminum (5052-H32,   3003-H14, and 6061-T6),   Extruded Aluminum (6060-T6),   and Cold Rolled Steel, PC-ABS,   Santoprene, Nylon   Finish ......................................................Conductive Clear Iridite   on Aluminum   Electroplated Nickel   on Cold Rolled Steel   Polyurethane Enamel   NI PXIe-1065 User Manual   A-10   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix A   Specifications   Figures A-1 and A-2 show the NI PXIe-1065 chassis dimensions. The   holes shown are for the installation of the optional rack mount kits. You can   install those kits on the front or rear of the chassis, depending on which end   of the chassis you want to face toward the front of the instrument cabinet.   Notice that the front and rear chassis mounting holes (size M4) are   symmetrical.   Dimensions are in inches (millimeters)   .39   (9.9)   17.54 (445.6)   NI PXIe-1065   6.97   (177.1)   H 1 2 3 4 5 6 7 8 9 10   11 H   12 H   13 H   14   15   16   17   18   0.57   (14.5)   1.14   (29.1)   1.82   (46.3)   1.82   (46.3)   1.37   (34.8)   1.58   (40.1)   10.21 (259.1)   Front of   PXI Card   1.84   (46.8)   3.54   (90.0)   0.30 (7.25)   2.12   (53.8)   17.11 (434.6)   3.19   (81.1)   Figure A-1. NI PXIe-1065 Chassis Dimensions (Front and Side)   © National Instruments Corporation   A-11   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix A   Specifications   Figure A-3 shows the chassis rack mount kit components.   2 NI   PXI   e-106   5 3 1 1 Front Rack Mount Kit   2 NI Chassis   3 Optional Rear Rack Mount Kit   Figure A-3. NI Chassis Rack Mount Kit Components   Note The chassis shown in Figure A-3 is representative of the NI PXI-1044/1045 and   NI PXIe-1065 product line.   © National Instruments Corporation   A-13   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   B Pinouts   This appendix describes the connector pinouts for the NI PXIe-1065   chassis backplane.   Table B-1 shows the XP1 connector pinout for the System Controller slot.   Table B-2 shows the XP2 Connector Pinout for the System Controller slot.   Table B-3 shows the XP3 Connector Pinout for the System Controller slot.   Table B-4 shows the XP4 Connector Pinout for the System Controller slot.   Table B-5 shows the TP1 Connector Pinout for the System Controller slot.   Table B-6 shows the TP2 Connector Pinout for the System Timing slot.   Table B-7 shows the XP3 Connector Pinout for the System Timing slot.   Table B-8 shows the XP4 Connector Pinout for the System Timing slot.   Table B-9 shows the P1 connector pinout for the peripheral slots.   Table B-10 shows the P2 connector pinout for the peripheral slots.   Table B-11 shows the P1 connector pinout for the Hybrid peripheral slots.   Table B-12 shows the XP3 Connector Pinout for the Hybrid   peripheral slots.   Table B-13 shows the XP4 Connector Pinout for the Hybrid   peripheral slots.   For more detailed information, refer to the PXI-5 PXI Express Hardware   Specification, Revision 2.0. Contact the PXI Systems Alliance for a copy   of the specification.   © National Instruments Corporation   B-1   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix B   Pinouts   System Controller Slot Pinouts   Table B-1. XP1 Connector Pinout for the System Controller Slot   Pins   A Signals   GND   12V   B C 12V   D GND   5V   E F 3.3V   GND   G Table B-2. XP2 Connector Pinout for the System Controller Slot   Pin   A B ab   C D cd   E F ef   1 2 3 4 5 6 7 8 9 3PETp1   3PETn1   GND   3PERp1   3PERn1   GND   3PETp2   3PETn2   3PERn2   4PETn1   4PERn1   RSV   GND   3PETp3   4PETp0   4PETp2   4PETp3   RSV   3PETn3   4PETn0   4PETn2   4PETn3   RSV   GND   GND   GND   GND   GND   GND   GND   GND   GND   3PERp3   4PERp0   4PERp2   4PERp3   RSV   3PERn3   4PERn0   4PERn2   4PERn3   RSV   GND   GND   GND   GND   GND   GND   GND   GND   GND   3PERp2   4PETp1   4PERp1   RSV   GND   GND   GND   GND   GND   GND   GND   GND   GND   RSV   RSV   RSV   RSV   RSV   RSV   RSV   RSV   RSV   RSV   RSV   RSV   RSV   RSV   RSV   RSV   RSV   RSV   RSV   RSV   10   RSV   RSV   RSV   RSV   RSV   RSV   Table B-3. XP3 Connector Pinout for the System Controller Slot   Pin   A B ab   C D cd   E F ef   1 2 3 4 5 6 RSV   RSV   RSV   GND   RSV   RSV   GND   RSV   RSV   GND   GND   GND   GND   GND   GND   RSV   GND   GND   GND   GND   GND   PWR_OK   4RefClk+   3RefClk+   1PERp0   PS_ON#   4RefClk–   3RefClk–   1PERn0   1PERn2   GND   GND   GND   GND   GND   LINKCAP   2RefClk+   1RefClk+   1PETp1   PWRBTN#   2RefClk–   1RefClk–   1PETn1   1PERn1   SMBDAT   RSV   SMBCLK   PERST#   1PETn0   1PETn2   1PETp0   1PETp2   1PERp2   1PERp1   NI PXIe-1065 User Manual   B-2   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix B   Pinouts   Table B-3. XP3 Connector Pinout for the System Controller Slot (Continued)   Pin   A B ab   C D cd   E F ef   7 8 9 1PETp3   1PETn3   GND   1PERp3   1PERn3   GND   2PETp0   2PETn0   GND   2PETp1   2PETp2   3PETp0   2PETn1   2PETn2   3PETn0   GND   GND   GND   2PERp1   2PERp2   3PERp0   2PERn1   2PERn2   3PERn0   GND   GND   GND   2PERp0   2PETp3   2PERp3   2PERn0   2PETn3   2PERn3   GND   GND   GND   10   Table B-4. XP4 Connector Pinout for the System Controller Slot   Pin   Z GND   GND   GND   GND   GND   GND   GND   GND   A B C D E F 1 2 3 4 5 6 7 8 GA4   5Vaux   RSV   RSV   GA3   GND   RSV   RSV   GA2   GA1   GA0   GND   GND   GND   GND   GND   GND   GND   GND   SYSEN#   RSV   WAKE#   RSV   ALERT#   RSV   RSV   RSV   RSV   PXI_TRIG3   PXI_TRIG2   PXI_TRIG1   RSV   PXI_TRIG4   GND   PXI_TRIG5   RSV   GND   PXI_TRIG6   PXI_CLK10   PXI_TRIG7   PXI_LBR6   PXI_STAR   GND   PXI_TRIG0   GND   RSV   RSV   RSV   System Timing Slot Pinouts   Table B-5. TP1 Connector Pinout for the System Timing Slot   Pin   A B ab   C D cd   E F ef   1 PXIe_DSTARA3+   PXIe_DSTARC4+   PXIe_DSTARB4+   PXIe_DSTARA4+   PXIe_DSTARC5+   PXIe_DSTARB5+   PXIe_DSTARA5+   PXIe_DSTARC6+   PXIe_DSTARB6+   PXIe_DSTARA6+   PXIe_DSTARA3–   PXIe_DSTARC4–   PXIe_DSTARB4–   PXIe_DSTARA4–   PXIe_DSTARC5–   PXIe_DSTARB5–   PXIe_DSTARA5–   PXIe_DSTARC6–   PXIe_DSTARB6–   PXIe_DSTARA6–   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   NC   NC   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   NC   NC   NC   NC   NC   NC   NC   NC   NC   NC   NC   NC   NC   NC   NC   NC   NC   NC   NC   NC   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   2 PXI_STAR12   PXI_STAR13   3 NC   NC   4 NC   NC   5 PXI_STAR14   PXI_STAR15   6 NC   NC   NC   RSV   NC   NC   7 NC   8 PXI_STAR16   9 NC   NC   10   © National Instruments Corporation   B-3   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix B   Pinouts   Table B-6. TP2 Connector Pinout for the System Timing Slot   Pin   A B ab   C PXIe_DSTARC8+   NC   D PXIe_DSTARC8–   NC   cd   E F ef   1 NC   NC   NC   NC   NC   NC   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   PXIe_DSTARB8+   PXIe_DSTARB8–   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   2 PXIe_DSTARA8+   PXIe_DSTARA8–   3 PXIe_DSTARC1+   PXI_STAR0   PXI_STAR2   PXI_STAR4   PXI_STAR6   PXI_STAR8   PXI_STAR10   NC   PXIe_DSTARC1–   PXI_STAR1   PXI_STAR3   PXI_STAR5   PXI_STAR7   PXI_STAR9   PXI_STAR11   NC   NC   NC   4 PXIe_DSTARB1+   PXIe_DSTARA1+   PXIe_DSTARC2+   PXIe_DSTARB2+   PXIe_DSTARA2+   PXIe_DSTARC3+   PXIe_DSTARB3+   PXIe_DSTARB1–   PXIe_DSTARA1–   PXIe_DSTARC2–   PXIe_DSTARB2–   PXIe_DSTARA2–   PXIe_DSTARC3–   PXIe_DSTARB3–   NC   NC   5 NC   NC   6 NC   NC   7 NC   NC   8 PXIe_DSTARC11+   PXIe_DSTARA11+   PXIe_DSTARB11+   PXIe_DSTARC11–   PXIe_DSTARA11–   PXIe_DSTARB11–   9 10   Table B-7. XP3 Connector Pinout for the System Timing Slot   Pin   A PXIe_CLK100+   PRSNT#   SMBDAT   MPWRGD*   1PETp0   B PXIe_CLK100–   PWREN#   SMBCLK   PERST#   1PETn0   ab   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   C PXIe_SYNC100+   PXIe_DSTARB+   RSV   D PXIe_SYNC100–   PXIe_DSTARB–   RSV   cd   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   E PXIe_DSTARC+   PXIe_DSTARA+   RSV   F PXIe_DSTARC–   PXIe_DSTARA–   RSV   ef   1 GND   2 GND   GND   GND   GND   GND   GND   GND   GND   GND   3 4 RSV   RSV   1RefClk+   1PETp1   1RefClk–   1PETn1   5 1PERp0   1PERn0   6 1PETp2   1PETn2   1PERp2   1PERn2   1PERp1   1PERn1   7 1PETp3   1PETn3   1PERp3   1PERn3   1PETp4   1PETn4   8 1PETp5   1PETn5   1PERp5   1PERn5   1PERp4   1PERn4   9 1PETp6   1PETn6   1PERp6   1PERn6   1PETp7   1PETn7   10   RSV   RSV   RSV   RSV   1PERp7   1PERn7   Table B-8. XP4 Connector Pinout for the System Timing Slot   Pin   Z GND   GND   GND   GND   GND   GND   GND   GND   A B C D E F 1 2 3 4 5 6 7 8 GA4   5Vaux   12V   GA3   GND   12V   GA2   GA1   GA0   GND   SYSEN#   GND   WAKE#   GND   3.3V   ALERT#   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   3.3V   3.3V   PXI_TRIG3   PXI_TRIG4   GND   PXI_TRIG5   ATNLED   ATNSW#   RSV   GND   PXI_TRIG6   PXI_CLK10   PXI_TRIG7   PXI_LBR6   PXI_TRIG2   PXI_CLK10_IN   GND   PXI_TRIG1   PXI_TRIG0   GND   PXIe_SYNC_CTRL   PXI_LBL6   NI PXIe-1065 User Manual   B-4   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix B   Pinouts   Peripheral Slot Pinouts   Table B-9. P1 Connector Pinout for the Peripheral Slot   Pin   25   24   23   22   21   20   19   18   17   16   15   12–14   11   10   9 Z A B C D E F GND   5V   REQ64#   5V   ENUM#   V(I/O)   AD[3]   3.3V   3.3V   5V   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   AD[1]   3.3V   AD[0]   5V   ACK64#   AD[2]   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   AD[4]   GND   AD[7]   3.3V   AD[6]   M66EN   AD[11]   GND   AD[5]   AD[9]   GND   AD[8]   V(I/O)   AD[14]   3.3V   C/BE[0]#   AD[10]   AD[13]   C/BE[1]#   PERR#   LOCK#   TRDY#   AD[12]   3.3V   AD[15]   GND   SERR#   3.3V   PAR   IPMB_SCL   GND   IPMB_SDA   V(I/O)   GND   DEVSEL#   3.3V   STOP#   BD_SEL#   FRAME#   IRDY#   Key Area   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   AD[18]   AD[21]   C/BE[3]#   AD[26]   AD[30]   REQ#   AD[17]   GND   AD[16]   3.3V   GND   AD[20]   GND   AD[25]   GND   CLK   C/BE[2]#   AD[19]   AD[22]   AD[24]   AD[27]   AD[31]   GNT#   INTS   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   IDSEL   GND   AD[23]   V(I/O)   AD[28]   3.3V   8 7 AD[29]   GND   6 5 BRSVP1A5   IPMB_PWR   INTA#   BRSVP1B5   HEALTHY   INTB#   5V   RST#   GND   INTP   5V   4 V(I/O)   INTC#   TMS   3 INTD#   TDI   2 TCK   TDO   +12V   1 5V   –12V   TRST#   5V   © National Instruments Corporation   B-5   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix B   Pinouts   Table B-10. P2 Connector Pinout for the Peripheral Slot   Pin   Z A B C D E F 22   21   20   19   18   17   16   15   14   13   12   11   10   9 GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GA4   GA3   GA2   GA1   GA0   GND   PXI_LBR0   GND   PXI_LBR1   PXI_LBL0   PXI_LBL3   PXI_TRIG5   RSV   PXI_LBR2   GND   PXI_LBR3   PXI_LBL1   PXI_LBL5   PXI_TRIG6   PXI_CLK10   PXI_TRIG7   PXI_LBR6   RSV   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   PXI_LBR4   PXI_LBL2   PXI_TRIG3   PXI_TRIG2   PXI_TRIG1   PXI_LBR5   GND   PXI_LBL4   GND   PXI_TRIG4   GND   PXI_STAR   GND   PXI_TRIG0   GND   RSV   PXI_BRSVA15   RSV   RSV   PXI_LBL6   GND   RSV   RSV   RSV   GND   V(I/O)   RSV   RSV   RSV   RSV   RSV   GND   RSV   RSV   GND   V(I/O)   RSV   RSV   RSV   RSV   RSV   GND   RSV   RSV   GND   V(I/O)   RSV   RSV   RSV   8 RSV   RSV   GND   RSV   7 RSV   GND   V(I/O)   RSV   RSV   RSV   6 RSV   RSV   GND   RSV   5 RSV   GND   V(I/O)   RSV   RSV   RSV   4 V(I/O)   PXI_LBR7   PXI_LBR11   PXI_LBL9   64EN#   GND   GND   RSV   3 PXI_LBR8   UNC   PXI_LBR9   PXI_LBL7   PXI_LBL11   PXI_LBR10   PXI_LBL8   PXI_LBL12   2 PXI_LBR12   GND   1 PXI_LBL10   NI PXIe-1065 User Manual   B-6   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix B   Pinouts   Hybrid Slot Pinouts   Table B-11. P1 Connector Pinout for the Hybrid Slot   Pin   25   24   23   22   21   20   19   18   17   16   15   12–14   11   10   9 Z A B C D E F GND   5V   REQ64#   5V   ENUM#   V(I/O)   AD[3]   3.3V   3.3V   5V   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   AD[1]   3.3V   AD[0]   5V   ACK64#   AD[2]   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   AD[4]   GND   AD[7]   3.3V   AD[6]   M66EN   AD[11]   GND   AD[5]   AD[9]   GND   AD[8]   V(I/O)   AD[14]   3.3V   C/BE[0]#   AD[10]   AD[13]   C/BE[1]#   PERR#   LOCK#   TRDY#   AD[12]   3.3V   AD[15]   GND   SERR#   3.3V   PAR   IPMB_SCL   GND   IPMB_SDA   V(I/O)   GND   DEVSEL#   3.3V   STOP#   BD_SEL#   FRAME#   IRDY#   Key Area   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   AD[18]   AD[21]   C/BE[3]#   AD[26]   AD[30]   REQ#   AD[17]   GND   AD[16]   3.3V   GND   AD[20]   GND   AD[25]   GND   CLK   C/BE[2]#   AD[19]   AD[22]   AD[24]   AD[27]   AD[31]   GNT#   INTS   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   IDSEL   GND   AD[23]   V(I/O)   AD[28]   3.3V   8 7 AD[29]   GND   6 5 BRSVP1A5   IPMB_PWR   INTA#   BRSVP1B5   HEALTHY#   INTB#   5V   RST#   GND   INTP   5V   4 V(I/O)   INTC#   TMS   3 INTD#   TDI   2 TCK   TDO   +12V   1 5V   –12V   TRST#   5V   © National Instruments Corporation   B-7   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix B   Pinouts   Table B-12. XP3 Connector Pinout for the Hybrid Slot   Pin   A B PXIe_CLK100–   PWREN#   SMBCLK   PERST#   1PETn0   ab   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   C PXIe_SYNC100+   PXIe_DSTARB+   RSV   D PXIe_SYNC100–   PXIe_DSTARB–   RSV   cd   E PXIe_DSTARC+   PXIe_DSTARA+   RSV   F PXIe_DSTARC–   PXIe_DSTARA–   RSV   ef   1 PXIe_CLK100+   PRSNT#   SMBDAT   MPWRGD*   1PETp0   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   2 3 4 RSV   RSV   1RefClk+   1PETp1   1RefClk-   1PETn1   5 1PERp0   1PERn0   6 1PETp2   1PETn2   1PERp2   1PERn2   1PERp1   1PERn1   7 1PETp3   1PETn3   1PERp3   1PERn3   1PETp4   1PETn4   8 1PETp5   1PETn5   1PERp5   1PERn5   1PERp4   1PERn4   9 1PETp6   1PETn6   1PERp6   1PERn6   1PETp7   1PETn7   10   RSV   RSV   RSV   RSV   1PERp7   1PERn7   Table B-13. XP4 Connector Pinout for the Hybrid Slot   Pin   Z GND   GND   GND   GND   GND   GND   GND   GND   A B C D E F 1 2 3 4 5 6 7 8 GA4   5Vaux   12V   GA3   GND   12V   GA2   GA1   GA0   GND   SYSEN#   GND   WAKE#   GND   3.3V   ALERT#   GND   GND   GND   GND   GND   GND   GND   GND   GND   GND   3.3V   3.3V   PXI_TRIG3   PXI_TRIG2   PXI_TRIG1   RSV   PXI_TRIG4   GND   PXI_TRIG5   ATNLED   ATNSW#   RSV   GND   PXI_TRIG6   PXI_CLK10   PXI_TRIG7   PXI_LBR6   PXI_STAR   GND   PXI_TRIG0   GND   PXI_LBL6   NI PXIe-1065 User Manual   B-8   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   C Technical Support and   Professional Services   Visit the following sections of the award-winning National Instruments   Web site at ni.com for technical support and professional services:   • Support—Technical support at ni.com/support includes the   following resources:   – Self-Help Technical Resources—For answers and solutions,   visit ni.com/support for software drivers and updates,   a searchable KnowledgeBase, product manuals, step-by-step   troubleshooting wizards, thousands of example programs,   tutorials, application notes, instrument drivers, and so on.   Registered users also receive access to the NI Discussion Forums   at ni.com/forums. NI Applications Engineers make sure every   question submitted online receives an answer.   – Standard Service Program Membership—This program   entitles members to direct access to NI Applications Engineers   via phone and email for one-to-one technical support as well as   exclusive access to on demand training modules via the Services   Resource Center. NI offers complementary membership for a full   year after purchase, after which you may renew to continue your   benefits.   For information about other technical support options in your   area, visit ni.com/services, or contact your local office at   ni.com/contact.   • • Training and Certification—Visit ni.com/training for   self-paced training, eLearning virtual classrooms, interactive CDs,   and Certification program information. You also can register for   instructor-led, hands-on courses at locations around the world.   System Integration—If you have time constraints, limited in-house   technical resources, or other project challenges, National Instruments   Alliance Partner members can help. To learn more, call your local   NI office or visit ni.com/alliance.   © National Instruments Corporation   C-1   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Appendix C   Technical Support and Professional Services   • Declaration of Conformity (DoC)—A DoC is our claim of   compliance with the Council of the European Communities using   the manufacturer’s declaration of conformity. This system affords   the user protection for electromagnetic compatibility (EMC) and   product safety. You can obtain the DoC for your product by visiting   ni.com/certification.   If you searched ni.com and could not find the answers you need, contact   your local office or NI corporate headquarters. Phone numbers for our   worldwide offices are listed at the front of this manual. You also can visit   the Worldwide Offices section of ni.com/niglobal to access the branch   office Web sites, which provide up-to-date contact information, support   phone numbers, email addresses, and current events.   NI PXIe-1065 User Manual   C-2   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Glossary   Symbol   Prefix   pico   Value   10–12   10–9   10– 6   10–3   103   p n nano   micro   milli   kilo   μ m k M G T mega   giga   106   109   tera   1012   Symbols   ° Degrees.   ≥ ≤ % Equal or greater than.   Equal or less than.   Percent.   A A Amperes.   AC   Alternating current.   ANSI   Auto   AWG   American National Standards Institute.   Automatic fan speed control.   American Wire Gauge.   © National Instruments Corporation   G-1   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Glossary   B backplane   An assembly, typically a printed circuit board, with connectors and signal   paths that bus the connector pins.   BNC   Bayonet Neill Concelman connector; a commonly used coaxial connector.   C C Celsius.   cfm   Cubic feet per minute.   Code of Federal Regulations.   Centimeters.   CFR   cm   CompactPCI   An adaptation of the Peripheral Component Interconnect (PCI)   Specification 2.1 or later for industrial and/or embedded applications   requiring a more robust mechanical form factor than desktop PCI. It   uses industry standard mechanical components and high-performance   connector technologies to provide an optimized system intended for rugged   applications. It is electrically compatible with the PCI Specification, which   enables low-cost PCI components to be utilized in a mechanical form factor   suited for rugged environments.   CSA   Canadian Standards Association.   D daisy-chain   A method of propagating signals along a bus, in which the devices are   prioritized on the basis of their position on the bus.   DB-9   DC   A 9-pin D-SUB connector.   Direct current.   DoC   Declaration of Conformity.   Subminiature D connector.   D-SUB   NI PXIe-1065 User Manual   G-2   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Glossary   E efficiency   Ratio of output power to input power, expressed as a percentage.   Electronic Industries Association.   EIA   EMC   EMI   Electromagnetic Compatibility.   Electromagnetic Interference.   F FCC   Federal Communications Commission.   filler panel   A blank module front panel used to fill empty slots in the chassis.   G g (1) grams; (2) a measure of acceleration equal to 9.8 m/s2.   General Purpose Interface Bus (IEEE 488).   GPIB   gRMS   A measure of random vibration. The root mean square of acceleration   levels in a random vibration test profile.   H hr   Hours.   Hz   Hertz; cycles per second.   I IEC   International Electrotechnical Commission; an organization that sets   international electrical and electronics standards.   IEEE   IMP   Institute of Electrical and Electronics Engineers.   Mainframe peak current.   © National Instruments Corporation   G-3   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Glossary   in.   Inches.   inhibit   To turn off.   J jitter   A measure of the small, rapid variations in clock transition times from their   nominal regular intervals. Units: seconds RMS.   K kg   Kilograms.   Kilometers.   km   L lb   Pounds.   LED   Light emitting diode.   line regulation   The maximum steady-state percentage that a DC voltage output will   change as a result of a specified change in input AC voltage (step change   from 90 to 132 VAC or 180 to 264 VAC).   load regulation   The maximum steady-state percentage that a DC voltage output will   change as a result of a step change from no-load to full-load output current.   M m Meters.   MHz   mi   Megahertz. One million Hertz; one Hertz equals one cycle per second.   Miles.   ms   Milliseconds.   MTBF   MTTR   Mean time between failure.   Mean time to repair.   NI PXIe-1065 User Manual   G-4   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Glossary   N NEMA   National Electrical Manufacturers Association.   National Instruments.   NI   P power supply shuttle   A removable module that contains the chassis power supply.   PCI eXtensions for Instrumentation.   PXI   PXI_CLK10   10 MHz PXI system reference clock.   R RH   Relative humidity.   Root mean square.   RMS   S s Seconds.   skew   Deviation in signal transmission times.   slot blocker   An assembly installed into an empty slot to improve the airflow in adjacent   slots.   standby   The backplane is unpowered (off), but the chassis is still connected to AC   power mains.   System controller   A module configured for installation in Slot 1of a PXI chassis. This device   is unique in the PXI system in that it performs the system controller   functions, including clock sourcing and arbitration for data transfers across   the backplane. Installing such a device into any other slot can damage the   device, the PXI backplane, or both.   © National Instruments Corporation   G-5   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Glossary   system reference   clock   A 10 MHz clock, also called PXI_CLK10, that is distributed to all   peripheral slots in the chassis, as well as a BNC connector on the rear of   chassis labeled 10 MHz REF OUT. The system reference clock can be used   for synchronization of multiple modules in a measurement or control   system. The 10 MHz REF IN and OUT BNC connectors on the rear of the   chassis can be used to synchronize multiple chassis to one reference clock.   The PXI backplane specification defines implementation guidelines for   PXI_CLK10.   System Timing slot   This slot is located at slot 4 and has dedicated trigger lines to other slots.   T TTL   Transistor-transistor logic.   U UL   Underwriter’s Laboratories.   V V Volts.   VAC   Vpp   Volts alternating current.   Peak-to-peak voltage.   W W Watts.   NI PXIe-1065 User Manual   G-6   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Index   CompactPCI   A AC power cables (table), 1-2   and operation   B backplane   hybrid peripheral slots, 1-7   interoperability with CompactPCI, 1-6   overview, 1-6   PXI Express peripheral slots, 1-8   PXI local bus, routing, 1-9   PXI peripheral slots, 1-7   PXIe_SYNC_CTRL, 1-14   specifications, A-7   air cooling of PXIe-1065 chassis, 2-2   filler panel installation, 2-5   system controller slot, 1-6   system reference clock, 1-11   default behavior (figure), 1-12   system timing slot, 1-8   D DB-9 connector   pinout (table), 2-10   power supply voltages (table), 2-11   Declaration of Conformity (NI resources), C-2   diagnostic tools (NI resources), C-1   dimensions (figure), A-11, A-12   documentation   C cables, power (table), 1-2   CE compliance, specifications, A-6   chassis ambient temperature definitions, 2-4   chassis cooling considerations   ambient temperature definitions, 2-4   clearances, 2-2   figure, 2-3   vents (figure), 2-4   electromagnetic compatibility, A-5   EMC filler panel kit, 1-5   environmental management, specifications, A-6   WEEE information, A-6   examples (NI resources), C-1   external clock source specifications, A-8   chassis initialization file, 2-16   chassis ventilation (figure), 2-4   clearances for chassis cooling, 2-2   figure, 2-3   CLK10 rear connectors, 2-12   © National Instruments Corporation   I-1   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Index   setting fan speed, 2-5   site considerations, 2-2   slot blocker installation, 2-5   testing power up, 2-6   F fan, setting speed, 2-5   filler panel installation, 2-5   unpacking the PXIe-1065, 1-1   installing a PXI Express system controller   instrument drivers (NI resources), C-1   G ground, connecting, 2-5   H help, technical support, C-1   hybrid peripheral slots, description, 1-7   hybrid slot pinouts   K kit contents, 1-1   XP4 connector (table), B-8   I IEC 320 inlet, 1-5, 2-6   inhibit mode switch, 2-12   installation, configuration, and operation   chassis initialization file, 2-16   configuration in MAX (figure), 2-13   connecting safety ground, 2-5   filler panel installation, 2-5   controller, 2-6   M maintenance of NI PXIe-1065 chassis, 3-1   cleaning   interior cleaning, 3-1   preparation, 3-1   resetting the AC mains circuit   breaker, 3-2   module installation   static discharge damage (caution), 3-1   figure, 2-9   services, C-1   PXI Express system controller installed in   a NI PXIe-1065 chassis (figure), 2-8   rack mounting, 2-5   NI PXIe-1065   fan speed, setting, 2-5   front view (figure), 1-4   installation. See installation,   configuration, and operation   remote voltage monitoring and inhibiting   interface, 2-10   NI PXIe-1065 User Manual   I-2   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Index   key features, 1-2   NI PXIe-1065 chassis   optional equipment, 1-5   rack mounting, 2-5   connecting to, 2-6   interface, 2-10   replacing, 3-3   rear view of NI PXIe-1065 chassis, 1-5   safety ground, connecting, 2-5   unpacking, 1-1   configuration, 3-4   installation, 3-3   NI PXIe-1065 backplane   hybrid peripheral slots, 1-7   interoperability with CompactPCI, 1-6   overview, 1-6   removal, 3-3   voltages at voltage monitoring connector   (DB-9) (table), 2-10   PXI Express peripheral slots, 1-8   PXI local bus, routing, 1-9   PXI peripheral slots, 1-7   PXIe_SYNC_CTRL, 1-14   using as restart (figure), 1-14   specifications, A-7   system controller slot, 1-6   system reference clock, 1-11   default behavior (figure), 1-12   routing (figure), 1-12   PXI differential star trigger specifications   (PXIe-DSTARA, PXIe-DSTARB,   installing in a NI PXIe-1065 chassis   (figure), 2-8   system timing slot, 1-8   PXI local bus, routing, 1-9   PXI peripheral slots, description, 1-7   PXI star trigger specifications, A-9   PXI star, routing, 1-9   trigger bus, 1-10   NI support and services, C-1   O PXI-1 configuration in MAX, 2-13   PXIe_DSTAR, routing, 1-9   PXIe_SYNC_CTRL, 1-14   PXIe_SYNC_CTRL specifications, A-9   optional equipment, 1-5   P peripheral module installation, 2-8   figure, 2-9   peripheral slot pinouts   rack mount kit dimensions (figure), A-13   rack mounting, 2-5   P1 connector (table), B-5   P2 connector (table), B-6   pinouts, B-1   kit, 1-5   recycling hardware, A-6   related documentation, viii   DB-9 connector (table), 2-10   power cables (table), 1-2   power inhibit switch LED indicator, 2-10   © National Instruments Corporation   I-3   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   Index   remote voltage monitoring and inhibiting   interface, 2-10   replacing the power supply, 3-3   mechanical, A-9   PXI differential star triggers   PXIe-DSTARC), A-9   S PXI star trigger, A-9   safety and caution notices, 2-1   safety ground, connecting, 2-5   safety, specifications, A-5   service interval, 3-1   setting fan speed, 2-5   slot blocker   PXIe_SYNC_CTRL, A-9   rack mount kit dimensions (figure), A-13   safety, A-5   shock and vibration, A-4   system reference clocks, A-7   static discharge damage (caution), 3-1   support, technical, C-1   system controller slot   installation, 2-5   kit, 1-6   software (NI resources), C-1   specifications   description, 1-6   pinouts   XP1 connector (table), B-2   XP2 connector (table), B-2   XP3 connector (table), B-2   XP4 connector (table), B-3   system reference clock, 1-11   default behavior (figure), 1-12   routing (figure), 1-12   sound pressure level (at operator   backplane   100 MHz system reference clock   specifications, A-7   system timing slot   description, 1-8   pinouts   PXIe_SYNC100), A-7   CE compliance, A-6   chassis cooling, A-3   dimensions (figure), A-11, A-12   electrical   TP1 connector (table), B-3   AC input, A-1   DC output, A-2   electromagnetic compatibility, A-5   environmental   technical support, C-1   operating environment, A-4   storage environment, A-4   environmental management, A-6   WEEE information, A-6   external clock source, A-8   testing power up, 2-6   training and certification (NI resources), C-1   trigger bus, 1-10   troubleshooting (NI resources), C-1   NI PXIe-1065 User Manual   I-4   ni.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Index   U unpacking the NI PXIe-1065 chassis, 1-1   Web resources, C-1   WEEE information, A-6   V voltage monitoring connector. See DB-9   connector   voltages at voltage monitoring connector   (DB-9) (table), 2-11   © National Instruments Corporation   I-5   NI PXIe-1065 User Manual   Download from Www.Somanuals.com. All Manuals Search And Download.   |