OPERATION AND PARTS MANUAL
Submersible Pumps
Model ST-2005 Series
Revision #3 (09/21/04)
THIS MANUAL MUST ACCOMPANY
THE EQUIPMENT AT ALLTIMES.
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP —TABLE OF CONTENTS
MultiquipST-2005Series
Submersible Pumps
Submersible Pump
ComponentDrawings
Here's How To Get Help ............................................ 2 ST-2005T& ST-2005TCUL Pump Assemblies ...26-27
Table Of Contents ..................................................... 3 ST-2005, ST-2005A, & ST-2005CUL Pump
Parts Ordering Procedures ....................................... 4 Assemblies .........................................................28-31
Safety Message Alert Symbols ................................. 5 ST-2005SB Pump Assembly ............................. 32-33
Rules For Safe Operation ...................................... 6-7 ST-2005T Electric Motor Assembly................... 34-35
Dimensions ............................................................... 8 ST-2005TCUL Electric Motor Assembly............ 36-37
Specifications (Pump/Control Box) ...........................9
General Information ................................................10
Components............................................................11
Float Switches .........................................................12
Float Switch (Piggy-Back) .......................................13
Float Switch (Control Box) ......................................14
Operation ................................................................15
Control Box Installation ..................................... 16-17
Clean-up .................................................................18
Maintenance ...........................................................19
Troubleshooting (Pump)..........................................20
Performance Curves ...............................................21
Wiring Diagrams (Electric Motor/Control Box) ........22
Explanation Of Codes In Remarks Column ............24
Suggested Spare Parts ...........................................25
ST-2005CUL Electric Motor Assembly .............. 38-39
ST-2005SB Electric Motor Assembly ................ 40-41
Terms and Condition of Sale
—
Parts .....................42
As a continuing effort to update
our parts book, contact the
MULTIQUIP literature department
for the latest revision of your
"Operation and Parts Manual"
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 3
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP — PARTS ORDERING PROCEDURES
When ordering parts,
please supply the following information:
❒
❒
❒
❒
❒
❒
❒
Dealeraccountnumber
Dealernameandaddress
Shipping address (if different than billing address)
Returnfaxnumber
Applicable model number
Quantity,part number and description of each part
Specifypreferredmethodofshipment:
✓
✓
✓
✓
✓
✓
FedEx or UPS Ground
FedEx or UPS Second Day or Third Day
FedEx or UPS Next Day
Federal Express Priority One
DHL
Note:Unlessotherwiseindicatedbycustomer, all
orders are treated as “Standard Orders”, and will
ship within 24 hours.We will make every effort to ship
“Air Shipments” the same day that the order is
received, if prior to 2PM west coast time. “Stock
Orders” must be so noted on fax or web forms.
Truck
Place Your Parts Order Via Web or Fax
For Even More Savings!
Here’s how to get help...
Please have the model and serial number
on hand when calling.
(Domestic USA Dealers Only)
MULTIQUIP CORPORATE OFFICE
18910 Wilmington Ave.
Carson, CA 90746
Email: [email protected]
800-421-1244
FAX: 310-537-3927
Extra Discounts!
All parts orders which include complete part numbers and
are received by our automated web parts order system, or
by fax qualify for the following extra discounts:
Ordered
via
Standard
orders
Stock orders
PARTS DEPARTMENT
800-427-1244
310-537-3700
MAYCO PARTS
800-306-2926
310-537-3700
SERVICE DEPARTMENT
800-421-1244
310-537-3700
TECHNICAL ASSISTANCE
800-478-1244
WARRANTY DEPARTMENT
800-421-1244, EXT. 279
310-537-3700, EXT. 279
($750 list and above)
FAX: 800-672-7877
FAX: 310-637-3284
Fax
3%
5%
10%
10%
Web
FAX: 800-672-7877
FAX: 310-637-3284
Special freight allowances
when you order 10 or more
line items via Web or Fax!**
FedEx Ground Service at no charge for freight
No other allowances on freight shipped by any other carrier.
FAX: 310-537-4259
FAX: 310-631-5032
FAX: 310-537-1173
**Common nuts, bolts and washers (all items under $1.00
list price) do not count towards the 10+ line items.
NOTE:DISCOUNTSARESUBJECTTOCHANGE
MULTIQUIP INC.
Direct TOLL-FREE access
to our Parts Department:
18910WILMINGTON AVENUE
POST OFFICE BOX 6254
CARSON, CALIFORNIA 90749
310-537-3700 • 800-421-1244
FAX:310-537-3927
Toll-free nationwide — 800-427-1244
INTERNET:www.multiquip.com
Toll-free FAX — 800-6-PARTS-7 (800/672-7877)
PAGE 4 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP — SAFETY MESSAGE ALERT SYMBOLS
FORYOUR SAFETY ANDTHE SAFETY OF OTHERS!
HAZARD SYMBOLS
Rotating Parts
Safety precautions should be followed at all times when
operating this equipment. Failure to read and understand the
Safety Messages and Operating Instructions could result in
injury to yourself and others.
NEVER operate equipment with covers,
This Owner's Manual has been
developed to provide complete
instructions for the safe and efficient
or guards removed. Keep fingers, hands,
hair and clothing away from all moving
parts to prevent injury.
operation of the Multiquip Model ST-
2005 Series Submersible Pumps.
Before using these pumps, ensure
that the operating individual has read
and understands all instructions
in this manual.
Accidental Starting
ALWAYS place the power source circuit
breaker or ON/OFF switch in the OFF
position, when the pump is not in use.
SAFETY MESSAGE ALERT SYMBOLS
The three (3) Safety Messages shown below will inform you
about potential hazards that could injure you or others. The
Safety Messages specifically address the level of exposure to
the operator, and are preceded by one of three words: DANGER,
WARNING, or CAUTION.
Sight and Hearing hazard
ALWAYS wear approved eye and
hearing protection, if required.
DANGER
You WILL be KILLED or SERIOUSLY injured if you DO
NOT follow directions.
Respiratory Hazard
WARNING
ALWAYS wear approved respiratory
protection, if required.
You CAN be KILLED or SERIOUSLY injured if you DO
NOT follow directions.
CAUTION
Equipment Damage Messages
Other important messages are provided throughout this manual
to help prevent damage to your submersible pump, other property,
or the surrounding environment.
You CAN be INJURED if you DO NOT follow directions.
Potential hazards associated with the ST-2005 series
submersible pumps operation will be referenced with Hazard
Symbols which appear throughout this manual, and will be
referenced in conjunction with Safety Message Alert Symbols.
This submersible pump, other
property, or the surrounding
environment could be damaged if
you do not follow instructions.
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 5
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP —RULES FOR SAFE OPERATION
■
■
■
ALWAYS make sure submersible pump is grounded.
CAUTION
NEVER use gas piping as an electrical ground.
Failure to follow instructions in this manual may lead to serious
injury or even death! This equipment is to be operated by
trained and qualified personnel only! This equipment is for
industrial use only.
DO NOT place hands or fingers inside pump when pump is
running.
■
ALWAYS make certain that the voltage supplied to the pump
is correct. Always read the pump's nameplate to determine
what the power requirements are. The ST-2005 series
submersible pumps require 115VAC, 60 Hz (single-phase)
for normal operation.
The following safety guidelines should always be used when
operating the ST- 2005 Series Submersible Pumps:
GENERAL SAFETY
■
DO NOT restrict the flow of the discharge hose as it may
cause overheating.
■
DO NOT operate or servicing this equipment
before reading this entire manual.
■
■
Be careful of discharge whipping under pressure.
Make sure pump installation is accordance with national
and local electrical codes.
■
■
This equipment should not be operated by persons under 18
years of age.
■
■
ALWAYS have a qualified electrician perform the pump
wiring installation.
NEVER operate this equipment without proper protective
clothing, shatterproof glasses, steel-toed boots and other
protective devices required by the job.
ALWAYS mount the control box in a vertical position
protected from the elements.
■
■
■
NEVER handle pump's AC power cord with wet hands.
NEVER let an extension cord or plug connection lay in water.
NEVER stand in water while AC power cord is connected
to a power source.
■
■
NEVER operate this equipment when not feeling
well due to fatigue, illness or taking medicine.
■
■
■
■
■
NEVER use a pump with a defective, frayed power cord.
Check the power cord on the pump for cuts in the insulation.
NEVERoperatethisequipment under the influence
or drugs or alcohol.
NEVER use a extension cord that is frayed or damaged
where the insulation has been cut.
ALWAYS make certain that proper extension cord has been
selected for the job. See Table 4.
NEVER attempt to use the power cord as a lifting or lowering
device for the submersible pump.
When raising or lowering of the submersible pump is
required, always attach an adequate rope or lifting device
to the correct lifting point (handle) on the pump.
■
NEVER use accessories or attachments, which are not
recommended by Multiquip for this equipment. Damage to the
equipment and/or injury to user may result.
■
ALWAYS place the pump in an up-right position on a
platform before using. The platform will prevent the pump
from burrowing itself on soft sand or mud.
■
■
■
■
Manufacturer does not assume responsibility for any accident
due to equipment modifications.
Whenever necessary, replace nameplate, operation and safety
decals when they become difficult read.
■
■
■
■
NEVER operate pump on its side.
DO NOT allow the pump to freeze in water.
NEVER leave an open pump chamber unattended.
ALWAYS check the machine for loosened threads or bolts
before starting.
The electrical voltage required to operate the pump can
cause severe injury or even death through physical contact
with live circuits. ALWAYS disconnect the electrical power
from the pump before performing maintenance on the pump.
NEVER operate the submersible pump in an explosive
atmosphere or near combustible materials. An explosion or fire
could result causing severe bodily harm or even death.
PAGE 6 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP —RULES FOR SAFE OPERATION
■
ALWAYS make sure that electrical circuits are properly
grounded per the National Electrical Code (NEC) and
local codes before operating pump. Severe injury or death
by electrocution can result from operating an ungrounded
pump.
. Emergencies
■
ALWAYS know the location of the nearest fire extinguisher.
■
■
NEVER use this pump to remove water from a swimming pool
when people are in the water.
ALWAYS be sure the operator is familiar with proper safety
precautions and operations techniques before using
submersible pump.
■
■
ALWAYS check pump oil level only when pump is cool.
Expansion due to heat may cause hot! oil to spray from the oil
plug when the oil plug is removed.
■
ALWAYS know the location of the nearest and first aid kit.
DO NOT attempt to thaw-out a frozen pump by using a torch
or other source of flame. Application of heat in this manner
may heat the oil in the seal cavity above the critical point,
causing pump damage.
■
■
DO NOT pump water greater than 104° Fahrenheit. Also DO
NOT pump liquids containing acid or alkali.
ALWAYS check strainer before pumping. Make sure strainer
is not clogged. Remove any large objects, dirt or debris from
the strainer to prevent clogging.
■
In emergencies always know the location of the
nearest phone or keep a phone on the job site.
Also know the phone numbers of the nearest
ambulance, doctor and fire department. This
information will be invaluable in the case of an
emergency.
■
■
ALWAYS use a large basket strainer when pumping water
that contain large debris.
ALWAYS flush pump after use when pumping water
concentrated with heavy debris. Flush with clean fresh
water. It is very important to always flush the pump before
turning it off to prevent clogging.
■
■
ALWAYS store equipment properly when it is not being used.
Equipment should be stored in a clean, dry location out of the
reach of children.
ALWAYS read, understand, and follow procedures in
Operator’s Manual before attempting to operate equipment.
Maintenance Safety
■
NEVER lubricate components or attempt service on a running
machine.
■
ALWAYS allow the machine a proper amount of time to cool
before servicing.
■
■
Keep the machinery in proper running condition.
Fix damage to the machine immediately and always replace
broken parts.
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 7
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP —DIMENSIONS
Figure 1. ST-2005T Dimensions
PAGE 8 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP —SPECIFICATIONS
TABLE 1. SPECIFICATIONS
Model
ST-2005T
ST-2005C
ST-2005S
ST-2005CUL
ST-2005TCUL
Submersible Trash
Pump
Centrifugal
Submersible Pump
Centrifugal
Submersible Pump
Centrifugal
Submersible Pump
Submersible Trash
Pump
Type
Impeller
Cast Iron Ductile
2.00 in. (51 mm)
Cast Iron Ductile
2.00 in. (51 mm)
Stainless Steel
Cast Iron Ductile Cast Iron Ductile
2.00 in. (51 mm) 2.00 in. (51 mm)
Suction & Discharge Size
2.00 in. (51 mm)
72 gallons/minute
(273 liters/minute)
85 gallons/minute
(322 liters/minute)
70 gallons/minute
(265 liters/minute)
85 gallons/minute 72 gallons/minute
(322 liters/minute) (273 liters/minute)
Maximum Pumping Capacity
Max. Solids Diameter
Max Head
1.00 in. (25 mm.)
N/A
N/A
36 ft. (10.9 meters)
0.5 HP (0.37kw)
1Ø 115V
N/A
42 ft (12.8 meters
0.5 HP (0.37kw
1Ø 115V
1.00 in. (25 mm.)
34 ft. (10.3 meters)
0.5 HP (0.37kw)
1Ø 115V
34 ft. (10.3 meters) 42 ft (12.8 meters)
Power
0.5 HP (0.37kw)
1Ø 115V
0.5 HP (0.37kw)
1Ø 115V
Voltage Phase
Starting Amps
25
41
17
41
25
Running Amps
6.2
8
6.7
8
6.2
Control Box Required
Thermal Overlaod Protection
Rotation
NO (Note 3)
YES
NO (Note 3)
YES
NO (Note 3)
YES
NO (Note 3)
YES
NO (Note 3)
YES
CCW (Note 1)
180 cc. (Note 2)
Monthly (300 hrs.)
3550 +/- 30
25 FT. (7.6 cm.)
57 lbs. (26 Kg.)
CCW (Note 1)
150 cc. (Note 2)
Monthly (300 hrs.)
3550 +/- 30
25 FT. (7.6 cm.)
38 lbs. ( 17 Kg.)
CCW (Note 1)
230 cc. (Note 2)
Monthly (300 hrs.)
3550 +/- 30
25 FT. (7.6 cm.)
39 lbs. (18 Kg.)
CCW (Note 1)
180 cc. (Note 2)
Monthly (300 hrs.)
3550 +/- 30
25 FT. (7.6 cm.)
38 lbs. ( 17 Kg.)
CCW (Note 1)
180 cc. (Note 2)
Monthly (300 hrs.)
3550 +/- 30
25 FT. (7.6 cm.)
57 lbs. (26 Kg.)
Mechanical Oil seal Capacity
Check Frequency
RMP (Speed)
Power Cable Length
Dry Net weight
1.
2.
3.
Motor Rotation – Upon start-up, the pump "kicks" in the opposite direction of motor rotation. The correct rotation is
counterclockwise (CCW) as viewed from the impeller end of the pump.
Mechanical Oil Seal – Use a good grade 10 weight non-detergent hydraulic oil (i.e.ShellTurbo 32 or equivalent).Fill oil cavity
75% to 85% full (allow air space for expansion).
Control Box - Control box (Table 2) may be required for certain pumping applications.
Table 2. Control Box Specifications
Thermal
Overload
Protection Capability
Float
Switch
UL/CSA
Listed
Model No.
VoltageType
115 VAC, 60 Hz Single-
Phase
CB3
YES
YES YES
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 9
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP —GENERAL INFORMATION
If the pump was used to pump water containing mud, silt, use
clean water to flush out the pump after each use.
Introduction
The Multiquip Model ST-2005 series submersible pumps are
designed to pump water and is used for the draining (de-
watering) of swimming pools, well casings construction sites,
cofferdams, manholes, transformer vaults and excavations.
DO NOT allow the pump to run dry, as this will damage the
pump. During maintenance, dry running is permissible but only
for a few seconds.
NEVER lift the pump by its electrical power cord. ALWAYS lift
the pump by its carrying handle or attach a rope to the carrying
handle.
A cast iron ductile type impeller is attached to the output shaft of
a 0.5 HP electric motor which provides adequate power for
general purpose pumping.This submersible pump is supplied
complete with an electric power cable, and a discharge port
located at the top of the pump which accepts a 2-inch hose.
A pump fully submerged pump in liquid will not freeze, unless
the liquid freezes. DO NOT allow a partially submerged pump to
freeze.The expansion of water freezing in the volute may crack
the pump, causing expensive repairs. If there is any danger of
the pump being subjected to freezing temperatures, Lift the pump
from water and allow it to drain thoroughly.
This pump is ideal for portability because of its light weight and
carrying handle. For reliability and long life, a mechanical seal
provides shaft sealing, with an oil chamber separating the pump
section from the motor.
If the pump jams or the pump rotor locks for any reason,
disconnect the pump from the power source immediately.
Allowing the pump motor to cycle ON and OFF under an overload
condition can burn out the motor.
The pump when in use, should be installed as free standing
(upright position) on its strainer base. A 2-inch discharge hose
(not supplied) should be connected to the discharge port located
on top of the pump.The discharge hose should be adequately
supported to avoid stress on the pump.
When replacement of nuts and bolts is required, use only
recommended parts as referenced in the parts section of this
manual.This pump uses metric threads. DO NOT use english
measurement threads.
For maximum water flow, the discharge hose should be kept as
short as possible, and with minimum elevation above the pump.
Remember as the length and/or height of the discharge hose is
increased, the flow of water will be reduced. Also any reduction
in the hose size, and any fittings such as valves or outlet nozzles,
will restrict the water flow.
Control Box Installation Warnings
DANGER
To avoid back-siphonage when the pump is switched off, ensure
that the end of the discharge hose is installed above the water
level at the final discharge point.
When installing the CB3 control box, the
possibility exists of electrical shock,
electrocution and possibly death! NEVER have
untrained personnel perform the installation.
ALWAYS have qualified service personnel (licensed
electrician) perform the installation.
When the pump is switched off, the water remaining in the hose
will run back through the pump.This can be avoided by placing
a non-return valve in the hose nearest the pump.
NEVER use this submersible pump to pump flammable liquids
or operate in a explosive or flammable environment.
WARNING
Avoid using this pump in conditions where mud, grit, silt or other
debris are present.These conditions could cause blockage and
cause excessive pump wear.
Explosion or Fire Hazard exists if this
pump is used with flammable liquids. DO
NOT use this pump with flammable
liquids. DO NOT install this pump in
hazardous locations as defined by the National Electrical
Code, ANSI/NFPA 70.
DO NOT install the pump directly into an area where there is a
heavy build-up of mud, grit, silt or debris. If this condition is present,
install the pump on a platform before operating.
This pump must always be positioned on a platform in an upright
position. NEVER operate the pump by a suspended rope. To
prevent large solids from entering the pump, install a wire mesh
screen or similar barrier around the pump.
Failure to follow the above referenced precautions could result
in serious injury or death! Replace pump cord immediately if
cord becomes damaged or severed.This pump must be installed
in accordance with National Electric Code ANSI/NFPA 70 so as
to prevent moisture from entering or accumulating with the boxes,
conduit bodies fittings, float housing or cable.
PAGE 10 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP —COMPONENTS
Figure 2. Submersible Pump Components
Figures 2 shows the location of the basic components, for the
ST-2005 series submersible pumps. Listed below is a brief
explanation of each component.
6.
Carrying Handle – Always carry the submersible pump
by its handle. NEVER! carry the pump by its power cord.
Carrying or lifting the pump by the power cord, will cause
undue stress on the cord, and ultimately the cord will
become dislodged from the pump.
1.
Strainer Base – This strainer base is made of stainless
steel which is resistant to hardware corrosion. DO NOT
pump large objects or debris with this pump.This pump is
for pumping water only.For de-watering purposes, always
place the strainer base on a platform.
7.
Thermal Overload Protection – This pump is equipped
with a thermal overload protection device that will shutdown
the motor in the event of high operating temperatures.The
motor will automatically restart once the temperature returns
to an acceptable operating temperature.
2.
3.
Volute/Impeller – Impellers are constructed of high-chrome
ductile iron to minimizes wear and prolong service life.
8.
9.
Mechanical Oil Seal – This oil filled seal provides
lubrication when running the pump dry. NEVER! run the
pump dry. Running the pump dry will cause severe damage
to the pump.
Electric Motor – All 2005 series submersible pumps
utilizes a 60 Hz, single-phase, 115 VAC, 0.5 HP electric
motor. Consult with a licensed electrician before
connecting motor to a power source. Observe all city and
local safety codes.
Mechanical Oil Seal Plug – Remove this plug to check
and add hydraulic oil (Shell 32 or equivalent) to the oil
cavity.This oil protects the mechanical seal.Oil cavity should
be full enough to cover seal spring.
4.
5.
Discharge Port – Connect a 2-inch hose to this port.
Remember to adequately support the discharge hose to
avoid stress on the pump.
AC Power Cable – This unit is supplied with a 25 ft. (7.6
meters) AC power cable. Always check the cable for signs
of wear.NEVER! use a defective power cable.Replace the
cable immediately if the cable is worn or defective.
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 11
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP —FLOAT SWITCHES
Design Features
Float Switch Theory
Constructed of rigid, durable ABS polymer ultrasonically welded.
The all-steel mercury switch is held by positioning pins. Interior
is filled with cell foam.
Mercury monitoring is a mercury-switch actuated, liquid level
control that has proven to be more economical and longer lasting
than other types of liquid-level control systems, easily replacing
and improving upon diaphram switches, air bubble systems and
electro-mechanical switches most often relied upon in the past.
■
■
■
■
■
■
Suitable for most liquid environments.
Hermetically sealed.
How It Works
Thick-walled non-corrosive PVC plastic enclosure.
Pressure tested to 60 ft. (18.2 meters).
There is a tilt-sensitive mercury switch hermetically sealed within
each float. As the liquid level (water) rises or falls, the float changes
its angle until the mercury switch makes (close, Figure 4) or
breaks (open, Figure 5) the circuit. Maximum pumping range is
120 degrees. See Figure 3 below.
Mercury switch reliability, proven to 500,000 cycles.
Standard SJO, 16-gauge, 2 conductor cord (20 ft./6.09 m).
Figure 4. Float Switch (Closed)
Figure 3. Pumping Range (Float Switch)
Pumping Range
The pumping range of the pump is determined by the float switch
tether cord.UseTable 3 as guide line to determine your required
pumping range. Pumping ranges are based on non-turbulent
conditions. Range may vary due to water temperature and cord
shape. Please note as the tether length increases, so does the
variance of the pumping range.
Figure 5. Float Switch (Open)
Table 3. Pumping Range
6 in. 8 in.
2 in.
4 in.
10 in.
12 in.
14 in.
16 in.
Tether Length
5.08 cm. 10.16 cm. 15.24 cm. 20.32 cm. 25.4 cm. 30.48 cm. 35.56 cm. 40.64 cm.
6 in. 10 in. 14 in. 18 in. 22 in. 27 in. 31 in. 35 in.
15.24 cm. 25.4 cm. 35.56 cm. 45.72 cm. 55.88 cm. 68.58 cm. 78.74 cm. 88.9 cm.
Pumping Range
PAGE 12 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP —FLOAT SWITCH (PIGGY-BACK)
Float Switch
Single or dual control float switches can be used for the unattended operation of the submersible pump. When using the piggy-
back power configuration (plug), the ST-2005 series pumps DO NOT require the use of a control box.In this configuration (piggy-
back), the SW-1 (single float switch) or SW-2 (dual float switch) are required. Figure 6 is an example of a single float switch application.
MountingThe Float Switch
Figure 6 shows a single float switch
1.
Determine the required cord tether length as shown in
Figure 6 and Table 3.
NOTE
application. For dual float switch
capability use a Model SW-2 mercury
type float switch .
2.
3.
Place the cord into the clamp as shown in Figure 6.
Secure the clamp to the discharge hose as shown in Figure
5. DO NOT install cord under hose clamp.
4.
Using a screwdriver, tighten the hose clamp.DO NOT over-
tighten. Make sure the float cord is not allowed to touch the
excess hose clamp band during operation.
Figure 6. Single Float Switch
Application Diagram
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 13
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP — FLOAT SWITCH (CONTROL BOX)
Control Box (CB3)
For special remote pumping applications of the submersible pump, a control box (Model CB3) may be required.This water resistant
control box provides watertight housing and glands to prevent water from leaking into the box, and a float switch interface. When using
the CB3 control box, only the SW-1WOP float switch (2) can be used (no plug, bare wires).Shown below (Figure 7) is a wiring layout of
the CB3 control box. See page 22 for a wiring diagram of the control box.
Figure 7. CB3 Control Box and Dual Float Switch
Application Diagram
PAGE 14 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP — OPERATION
Hose Connections
1. Connect a 2-inch hose to the discharge port on the pump
as shown in Figure 8. Make sure that the hose is attached
correctly to the discharge port.
Pump Power Connections (Piggy-Back Cord Only)
1.
Make sure the circuit breaker supplying power to the pump
is in the OFF position.
2.
Connect the float switch or switches to the AC power
receptacle as shown in Figure 6.
Attaching Lifting Rope
1. Attach a suitable lifting cable (rope) to the carrying handle
(Figure 8) on the pump and lower the pump into place. For
applicationswherethereisanexcessiveamountofmud,grit
or silt, the use of a support platform is desirable. When
pumpingwaterfromswimmingpooltypeapplicationswhere
thereislittleornodebris,thesupportplatformisnotrequired
Figure 9. Submersible Pump Upright Position
(Incorrect)
3. If all of the pump's electrical requirements have been met,
placethecircuitbreakerorpowerON/OFFswitchintheON
position.
4. Waitafewsecondsandwatershouldbegintoflowfromthe
dischargehose.
5. Ifwaterisnotflowingfromthedischargehoseornotflowing
freelyafterafewminutes,removethepowerfromthepump
and check the system for leaks.
6. To stop the pump from pumping, place the circuit breaker
or ON/OFF switch in the OFF position.
DANGER
NEVER! grab or touch a live power cord (Figure 10). DO
NOT stand in water when connecting the pump's power cord
into a voltage source.The possibility exist of electrical shock,
electrocution and possibly death!
WET
HANDS
Figure 8. Submersible Pump Upright Position
(Correct)
2. Makesurethepumpisalwaysplacedinanuprightposition,
nottilted(Figure9).Neverpositionthepumpdirectlyonasoft,
loose bottom. Remember to attain maximum pumping ca-
pacity and prevent excessive wear, position the pump so it
will not burrow itself into sand or clay.
POWER
CORD
(POWER ON)
Figure 10. Power Cord (Wet Hands)
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 15
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP— CONTROL BOX INSTALLATION
Power Cord Requirements
DANGER
The ST-2005 series submersible
pumps are also designed to work
with a control box (Model CB3).This
When routing the 115 VAC, 60 Hz., single phase power via a
powercordtothecontrolbox,ALWAYSusethecorrectwiresize.
Please reference Table 4 below (Cord Length/Wire Size) to
determinethecorrectwiresize.Incorrectwire sizecanadversely
affecttheperformanceofthepump.
control box contains the necessary
electronics (electronic overload module, float switch
connections) to operate the pump. Remember this control
box contains hazardous voltages. Disconnect all sources
of power before installing or servicing. There exists the
possibility of electrocution, electric shock or burn, which
can cause severe bodily harm or even death!
TABLE 4. CORD LENGTH AND WIRE SIZES
AMPS
6
50 FT.
100 FT.
16 AWG
14 AWG
14 AWG
14 AWG
12 AWG
12 AWG
150 FT.
14 AWG
12 AWG
12 AWG
12 AWG
10 AWG
10 AWG
16 AWG
16 AWG
16 AWG
14 AWG
14 AWG
12 AWG
8
CAUTION
This control box should only be installed or serviced by a
licensed electrician or qualified personnel.
10
12
14
16
Control Box Mounting
Mountthecontrolboxinanuprightverticalposition.Makesure
the control box is securely fastened to a flat surface, that is free
of dust, dirt, moisture or any elements that may contaminate or
erode the electronic components of the control box.
Connecting Dual float Switch (SW-1WOP)To Control Box
1.
Remove the float switch input connector housing, then
route the float switch wires through the cable gland on the
control box. Attach the wires of the float switch to the
terminal block as indicated by Table 5 and Figure 6.
Single-Phase Power Installation (Input)
All ST-2005 series submersible pumps require 115V, 60 Hz.,
single-phase power for normal operation.
If you cannot determine what your pump's power
requirements are, look at the vendor supplied identification
name tag attached to the pump or please contact Multiquip's
Service/Technical Assistance department.
TABLE 5. FLOAT SWITCH CONNECTIONSS
TERMINAL BLOCK
FLOAT SWITCH
NUMBER
CAUTION
TERMINAL 1 (BLACK)
START
TERMINAL 2 (WHITE)
Applying incorrect power (voltage phasing) to the
submersiblepumpcancauseseveredamagetothepump.
Please make sure that the correct voltage and phase are
transferred to the pump at all times.
TERMINAL 7 (WHITE)
STOP
TERMINAL 8 (BLACK)
2.
3.
Tighten the connector housing to ensure a tight fit between
the cord and the connector body.This will prevent the cable
from pulling out of the terminal block and also prevent
moisture from entering the control box.
Determine the length of the float switch wires, then secure
float switch wires to pump discharge hose. See Figures 3
and 6 and Table 3 to determine the pumping range.
PAGE 16 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP— CONTROL BOX INSTALLATION
2.
Remove the pump AC input connector housing from the
control box, then route the power cord through the cable
gland on the control box.
Connecting AC Power to the Control Box
1.
2.
3.
The AC power cord (input) should have three wires. Each
wire is color coded. The colors are WHITE, BLACK and
GREEN.
3.
Connect the pump power cord to the contactor as shown in
Figure 7 and Table 7.
Remove the AC input connector housing from the control
box, then route the power cord through the cable gland on
the control box.
TABLE 7. AC OUTPUT POWER
CONNECTIONS TO PUMP
Connect the AC power cord to the contactor as shown in
Figure 7 and Table 6.
CABLE WIRE COLOR
BLACK
CONTACTOR
T1
T2
TABLE 6. AC INPUT POWER
CONNECTIONS TO CONTACTOR
S
WHITE
CABLE WIRE COLOR
BLACK
CONTACTOR
GREEN
GROUND
L1
L2
WHITE
Electrical connections to the power
source should only be performed by
a licensed electrician or qualified
personnel.
NOTE
GREEN
GROUND
3.
Tighten the connector housing to ensure a tight fit between
the power cord and the connector body. This will prevent
the cable from pulling out of the terminal block and also
prevent moisture from entering the control box.
Turning On The Pump
1. If all of the pump's electrical requirements have been met,
placethecircuitbreakerorpowerON/OFFswitchintheON
position.
Itisrecommendedthatthepowerbeing
2. The CB3 control box has an operation switch located on
thefrontcover.Thisswitchhas3positions, AUTO,MANUAL
and OFF. The AUTO position allows the pump to run in an
un-attendedmode.The MANUALpositionwillletthepump
runwithoutthefloatswitchescontrollingthepump.Whenin
the manual mode be careful not to let the pump run dry.
Severedamagetothepumpmayoccurifitisallowedtorun
dry.NEVER let the pump run dry.
supplied to the control box ALWAYS
be connected to a circuit breaker or
a quick disconnect switch. This
safetyfeatureallowsforquickremoval
of power from the control box in the
event of an emergency.
NOTE
4.
Connect the other end of the AC power cord to the voltage
source. Remember to provide a means of disconnecting
the power from the control box (circuit breaker or quick
disconnect switch). Also make sure to provide a good earth
ground to the control box.
3. Place the operation switch in the AUTO position. The AC
power indicator lamp should be lit (ON).
4. Waitafewsecondsandwatershouldbegintoflowfromthe
dischargehose.
Connecting AC Power to the Pump
1.
AC power is transferred to the pump via a contactor. The
coil of the contactor is energized or de-energized by the
opening and closing of the float switch contacts.The power
cord should have three wires. Each wire is color coded.
The colors are WHITE, BLACK and GREEN.
5. Ifwaterisnotflowingfromthedischargehoseornotflowing
freelyafterafewminutes,removethepowerfromthepump
and check the system for leaks.
6. Tostopthepumpfrompumping, placetheoperationswitch
in the OFF position.
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 17
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP —CLEAN-UP
Pump Shut-Down/Clean-up
1. Remove the power from the pump by turning off the circuit
breakerorswitchthatprovidespowertothepump.Remem-
bertomakesurethathandsaredry(notwet),andfeetarenot
standinginwaterwhenremovingdisconnectingpowerfrom
thepump.
2. Usingtheliftingrope,liftthepumpupfromitscurrentposition.
Removethedischargehosefromthedischargeportonthe
pump.
3. Removeallpowercablesandfloatswitchesfromthecontrol
box. Placecablesandfloatswitchesinasuitablecontainer
where they will not get damaged.
4. Ifthepumpwasusedtopumpmud,gritorsilt,flush vigorously
with clean water.
5. Removethepumpfromthewater.Wipeoffanymudordebris
that might have attached itself to the pump.
6. Store pump in a clean dry place away from dirt and debris.
PAGE 18 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP —MAINTENANCE
LUBRICATION
5. If oil level is low fill with SAE 10 weight non-detergent
hydraulicoil(i.e.ShellTurbo32 orequivalent). Filloilcavity
75% to 85% full (allow air space for expansion). See Table
1 for pump oil cavity capacity.
To check the oil level of the mechanical seal perform the
following:
1. Lay the pump (Figure 11) on its side with the oil plug facing
upwards.
IMPELLER
1. Make sure the clearance between the impeller and the
friction disk is approximately .012 - .020 inches (.304 - .508
mm.)
2. Remove oil fill plug.
3. Visually inspect oil plug hole to verify that oil cavity is full
enoughtocoversealspring.Checkevery300hours,change
hydraulic oil every 6 months (1,000 hours) or as needed.
2. Ifimpellerisdefectiveorbadlyworn,replaceimpellerimme-
diately.
4. While checking the hydraulic oil level, also check the
condition of the hydraulic oil in the seal cavity . Block the
opening with a finger and roll pump to one side to drain
oil into a small transparent container.If oil is cloudy or has
water in it, drain oil from pump cavity and replace hydrau-
lic oil. Check the seal for wear damage.
Figure 11. Checking Hydraulic Oil
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 19
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP —TROUBLESHOOTING
Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a
breakdown, useTable 8 (PumpTroubleshooting) as a basic guideline for troubleshooting the pump. If the problem cannot be
remedied, contact Multiquip's service department.
TABLE 8. PUMP TROUBLESHOOTING
SYMPTOM
POSSIBLE PROBLEM
SOLUTION
Check that proper voltage (115 VAC, 60 Hz, single-phase ) is being
supplied to the pump. Also check that there is an adequate amount
of current (amps) to run the pump. Check power source circuit
breaker.
Incorrect voltage/amps?
If using float switches check wiring, inspect power cord.
Replace fuse, check cause of blown fuse.
Check electrical connections?
Blown power fuse?
Pump Fails To Start
Disconnect power cord and check for clogging and improper impeller
clearance. Unclog pump. Check overload protection device.
Impeller locked?
Use multimeter to check motor insulation. Insulation resistance must
be approximately 15 megaohms. If resistance is low, disassemble
pump motor and bake windings to dry them.
Wet motor windings?
Defective motor and pump
bearings?
Check for excessive bearing wear, if worn replace bearings. Replace
motor if defective.
Twisted or restricted discharge
hose?
Lay hose flat un-kinked. Remove clog from hose line.
Clean strainer.
Clogged pump strainer?
Pump Fails to Deliver Full
Output
Use a voltmeter to check voltage while pump is energized. Voltage
must be within 10%. Check power source (no load and load). If an
extension cord is used, make sure it has adequate current-carrying
capacity for the required length.See Table 4.
Low voltage?
Impeller worn?
Replace impeller.
Replace water seal.
Tighten securely.
Defective water seal?
Loose Oil Fill Plug?
Water in Seal Oil
PAGE 20 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP — PERFORMANCE CURVES
ST-2005T Performance Curve
ST-2005CUL Performance Curve
60
40
20
60
40
20
TOTAL HEAD
TOTAL HEAD
Max 34 FT
Max 42 FT
CAPACITY
CAPACITY
Max 85 G.P.M
Max 72 G.P.M
Capacity(US.G.P.M)
0
0
30
60
30
60
90
90
Capacity(US.G.P.M)
0
ST-2005S Performance Curve
ST-2005C Performance Curve
60
60
TOTAL HEAD
TOTAL HEAD
Max 36 FT
Max 42 FT
CAPACITY
CAPACITY
Max 70 G.P.M
40
20
Max 85 G.P.M
40
20
Capacity(US.G.P.M)
0
30
60
90
Capacity(US.G.P.M)
30
60
90
Figure 12. Pump Performance Curves
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 21
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP — WIRING DIAGRAMS
PAGE 22 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE PAGE
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 23
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP — EXPLANATION OF CODE IN REMARKS
COLUMN
How to read the marks and remarks used in this parts
book.
he contents of this parts
atalog are subject to change
ithout notice.
NOTE
Items Found In the “Remarks” Column
Serial Numbers-Where indicated, this indicates a serial
number range (inclusive) where a particular part is used.
Model Number-Where indicated, this shows that the
corresponding part is utilized only with this specific model
number or model number variant.
Items Found In the “Items Number” Column
All parts with same symbol in the number column, , #,
+
, %, or
*
>
, belong to the same assembly or kit.
If more than one of the same
reference number is listed, the
last one listed indicates newest
(or latest) part available.
NOTE
PAGE 24 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005 SERIES SUB. PUMP — SUGGESTED SPARE PARTS
ST-2005T/TCUL SUBMERSIBLE PUMP
1 TO 3 UNITS
Qty.
P/N
Description
1 ............ 0202005T120................. AC CORD W/ GLAND
1 ............ 0202005T081................. OIL SEAL
1 ............ 0202005T112................. OIL SEAL
1 ............ 0202005T008................. PACKING, CASING
1 ............ 0202005T060................. MECHANICAL SEAL
1 ............ 0202005T074................. PACKING
1 ............ 0202005TCUL157 ......... PACKING
1 ............ 020200ST003 ................ IMPELLER
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 25
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005T/TCUL — ELECTRIC SUBMERSIBLE PUMP ASSY.
ST-2005T - ST-2005TCUL - ELECTRIC SUBMERSIBLE PUMP ASSY.
128
127
128
125
120
158
121
224
125
156
157
445
34
446
119
42
23
7
76
81
447
160
65
74
3
4
16
24
6
8
5
112
60
1
530
531
PAGE 26 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005T/TCUL — ELECTRIC SUBMERSIBLE PUMP ASSY.
ST-2005T - ST-2005TCUL - ELECTRIC SUBMERSIBLE PUMP ASSY.
NO
1
3
4
5
6
7
8
16
23
24
34
60
65
74
76
81
112
119
119
120
121
125
127
128
156
157
157
158
160
224
445
446
447
530
PART NO
PART NAME
QTY.
REMARK
0202005T001
0202005T003
0201503A004
0201503A005
0201503A006
0202005T007
0202005T008
0202005T016
0202005T023
0202005T024
0202005T034
0201503A060
0201503A065
0202005T074
0202005T076
0201503A081
0201503A112
0202005T119
0202005TCUL119
0201503UL120
0202005T121
0202005T125
0202005T127
0202005T128
0202005T156
0202005T157
0202005T157
0202005T158
0201503A160
0201503A224
0202005T445
0202005T446
0202005T447
0202005T530
CASING
1
1
1
1
1
1
1
IMPELLER
IMPELLER NUT
SPRING WASHER
IMPELLER KEY
CASING COVER
CASING PACKING
SHAFT ...................................... 1 .................... ST-2005TCUL ONLY
COMPANION FLANGE
PACKING
BOLT 8X20 MM
MECHANICAL SEAL
PLUG
PACKING
BOLT
1
3
2
1
1
1
3
1
1
OIL SEAL
OIL SEAL
MOTOR ..................................... 1 .................... ST-2005T ONLY
MOTOR ..................................... 1 .................... ST-2005TCUL ONLY
AC CORDW/CORD GLAND
CORD CLAMP
SCREW
CARRYING HANDLE
SCREW
HEAD COVER
PACKING ...................................1 .................... ST-2005TCUL ONLY
PACKING ...................................1 .................... ST-2005T ONLY
BOLT
SLEEVE
PLUG
1
1
2
1
2
1
4
1
1
1
1
1
1
CONDENSER STARTING
AUTO-CUT (PROTECTOR)
CENTRIFUGAL SWITCH
BOTTOM PLATE
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 27
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005/A/CUL — ELECTRIC SUBMERSIBLE PUMP ASSY.
ST-2005 - ST-2005A - ST-2005CUL SUBMERSIBLE PUMP ASSY.
102
104
263
265
266
641
121
120
236
125
563
103
127
123
122
174
60
65
131
214-1
224
1
132
474
299
129
179
445
446
119
81
130
447
160
47
3
6
5
4
214-2
8
176
177
112
146
147
PAGE 28 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005/A/CUL — ELECTRIC SUBMERSIBLE PUMP ASSY.
ST-2005 - ST-2005A - ST-2005CUL SUBMERSIBLE PUMP ASSY.
NO
1
3
4
5
6
8
47
47
PART NO
PART NAME
QTY.
REMARK
0202005A001
0202005A003
0201503A004
0201503A005
0201503A006
0201503UL008
0201503A047A
0201503A047B
0201503A060
0201503A065
0201503A081
0202005A102
0202005A103
0201503A104
0201503A112
0202005UL119
0201503UL120
0201503A121
0201503A122
0201503A123
0201503A125
0201503A127
0202005A129
0202005UL130
0202005A131
0201503A132
0210503A146
0201503A147
0201503A160
0202005UL174
CASING
1
1
1
1
1
1
1
1
1
1
1
IMPELLER
IMPELLER NUT
IMPELLER NUT WASHER
IMPELLER KEY
CASING PACKING
LINER (0.2MM)
LINER (0.3MM)
MECHANICAL SEAL
PLUG
60
65
81
OIL SEAL
102
103
104
112
119
120
121
122
123
125
127
129
130
131
132
146
147
160
174
DISCHARGE PORT ..................... 1 .................... ST-2005CUL AND ST-2005A ONLY
PACKING ..................................... 1 .................... ST-2005CUL AND ST-2005A ONLY
BOLT ............................................ 2 .................... ST-2005CUL AND ST-2005A ONLY
OIL SEAL FOR OIL CHAMBER... 1 .................... ST-2005CUL AND ST-2005A ONLY
MOTOR
1
1
1
1
1
2
1
1
1
4
4
1
3
1
1
AC CORDW/CORD GLAND
CORD CLAMP
HANGER METAL
CHAIN
SCREW
CARRYING HANDLE
FRAME COVER
PACKING
BOLT
SPRING WASHER
STRAINER
BOLT
SLEEVE
OUTER PIPE
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 29
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005/A/CUL — ELECTRIC SUBMERSIBLE PUMP ASSY.
ST-2005 - ST-2005A - ST2005CUL SUBMERSIBLE PUMP ASSY.
102
104
263
265
266
641
121
120
236
125
563
103
127
123
122
174
60
65
131
214-1
224
1
132
474
299
129
179
445
446
119
81
130
447
160
47
3
6
5
4
214-2
8
176
177
112
146
147
PAGE 30 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005/A/CUL — ELECTRIC SUBMERSIBLE PUMP ASSY.
ST-2005 - ST-2005A - ST-2005CUL SUBMERSIBLE PUMP ASSY.
NO
176
177
179
PART NO
PART NAME
SUC COVER
BOLT
PACKING
PACKING
PACKING
PLUG
S-TIP
WASHER
QTY.
REMARK
0202005A176
0201503A177
0202005A179
1
4
1
1
1
1
1
2
4
4
4
4
1
214-1 0201503UL214A
214-2 0201503A214B
224
236
263
265
266
299
299
445
446
446
447
447
474
563
641
0201503A224
0202005S236
0401450080
011206020
BOLT
WASHER
952404470
0202005299
0202005A299
0202005A445
0202005UL446
0202005A446
0202005A447
0201503A447
0201503A474
0201503A563
030208200
SCREW 5 X 30
SCREW 6MM X 40MM
CONDENSER STARTING
AUTO-CUT ................................... 1 .................... ST-2005CUL ONLY
AUTO-CUT ................................... 1 .................... ST-2005 & ST-2005A ONLY
CENTRIFUGAL SWITCH .............. 1 ................... ST-2005A&ST-2005CULONLY
CENTRIFUGAL SWITCH ............. 1 .................... ST-2005 ONLY
WASHER
4
SPLIT PIN.................................... 2 .................... ST-2005A&ST-2005CULONLY
SPRING WASHER ....................... 4 .................... ST-2005CUL ONLY
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 31
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005SB — ELECTRIC SUBMERSIBLE PUMP ASSY.
ST-2005SB SUBMERSIBLE PUMP ASSY.
PAGE 32 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005SB — ELECTRIC SUBMERSIBLE PUMP ASSY.
ST-2005SB SUBMERSIBLE PUMP ASSY.
NO
1
3
4
5
6
8
47
60
PART NO
PART NAME
CASING
IMPELLER
IMPELLER NUT
IMPELLER NUT WASHER
IMPELLER KEY
CASING PACKING
LINER
MECHANICAL SEAL
PLUG
OIL SEAL
MOTOR
AC CORDW/CORD GLAND
CORD CLAMP
CHAIN
QTY.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
4
1
1
1
4
4
1
1
1
1
2
1
1
1
1
1
1
4
4
4
2
REMARK
0202005SB001
0202005S003
0202005SB004
0202005SB005
0202005SB006
0202005SB008
0202005S047
0202005S060
0202005S065
0201503A081
0202005SB119
0202005S120
0202005S121
0202005S123
0202005SB125
0202005SB126
0202005S127
0202005SB156
0202005SB158
0202005S160
0202005SB174
0202005SB176
0202005SB177
0202005SB178
0202005SB179
0202005SB214
0202005SB224
0202005SB236
0202005S358
0202005S386
0202005SB445
0202005SB446
0202005SB447
0202005S513
0202005S530
0202005S531
0202005S532
0202005S533
0202005S877
65
81
119
120
121
123
125
126
127
156
158
160
174
176
177
178
179
214
224
236
358
386
445
446
447
513
530
531
532
533
877
NUT
SPRING WASHER
CARRYING HANDLE
HEAD COVER
BOLT
SLEEVE
OUTER PIPE
SUC COVER
BOLT
SPRING WASHER
PACKING
PACKING
BOLT
S-TIP
SLEEVE
STRAINER NET
CONDENSER
AUTO-CUT (PROTECTOR)
CENTRIFUGAL SWITCH
PROTECT BAND
BOTTON PLATE
STUD BOLT
NUT 6 MM
SETTING SLEEVE
NUT
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 33
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005T — ELECTRIC MOTOR ASSY.
ST-2005T ELECTRIC MOTOR ASSY.
PAGE 34 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005T — ELECTRIC MOTOR ASSY.
ST-2005T ELECTRIC MOTOR ASSY.
NO
112
269
270
273
445
446
PART NO
PART NAME
QTY.
REMARK
0202005T112
0202005T269
0202005T270
0202005T273
0202005T445
0202005T446
0202005T4471
0202005T4472
0202005T539
0202005T606
0202005S607
0202005T608
0202005T119
OIL SEAL
1
1
1
1
1
1
1
1
1
1
1
1
*
*
*
*
*
*
MOTOR B BRACKET
MOTOR ROTOR
MOTOR STATOR
CONDENDER (STARTING)
AUTO-CUT (PROTECTOR)
CENTRIFUGAL SWITCH-1
CENTRIFUGAL SWITCH-2
SNAP RING
MOTOR A BEARING
MOTOR B BEARING
WAVE WASHER
447-1
447-2
*
*
539
*
606
*
607
*
608
A
*
MOTOR ASSEMBLY ..................... 1.................... INCLUDES ITEMS W/
*
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 35
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005TCUL — ELECTRIC MOTOR ASSY.
ST-2005TCUL ELECTRIC MOTOR ASSY.
PAGE 36 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005TCUL — ELECTRIC MOTOR ASSY.
ST-2005TCUL ELECTRIC MOTOR ASSY.
NO
112
269
270
273
445
446
PART NO
PART NAME
QTY.
REMARK
0202005T112
0202005T269CUL
0202005T270
0202005T273
0202005T445
0202005T446
0202005T4471
0202005T4472
0202005T539
0202005T606
0202005S607
0202005T608
0202005TCUL119
OIL SEAL
1
1
1
1
1
1
1
1
1
1
1
1
*
*
*
*
*
*
MOTOR B BRACKET
MOTOR ROTOR
MOTOR STATOR
CONDENDER (STARTING)
AUTO-CUT (PROTECTOR)
CENTRIFUGAL SWITCH-1
CENTRIFUGAL SWITCH-2
SNAP RING
MOTOR A BEARING
MOTOR B BEARING
WAVE WASHER
447-1
447-2
*
*
539
*
606
*
607
*
608
A
*
MOTOR ASSEMBLY ..................... 1.................... INCLUDES ITEMS W/
*
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 37
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005CUL — ELECTRIC MOTOR ASSY.
ST-2005CUL ELECTRIC MOTOR ASSY.
PAGE 38 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005CUL — ELECTRIC MOTOR ASSY.
ST-2005CUL ELECTRIC MOTOR ASSY.
NO
PART NO
PART NAME
QTY.
1
1
1
4
4
1
1
1
1
1
1
1
1
1
1
REMARK
112
0201503A112
0202005A129
0202005UL130
0202005A131
0201503A132
0201503A268
0202005A269
0202005UL270
0202005UL273
0202005A445
0202005UL446
0202005T4471
0201503A4472
0202005T539
0201503UL540
0201503UL541
0202005T606
0202005S607
0202005T608
0202005UL119
OIL SEAL
*
129*
130*
131*
132*
268*
269
270
273
445
446
447-1
447-2
539
540*
541*
MOTOR HEAD COVER
PACKING
BOLT
SPRING WASHER
MOTOR A BRACKET
MOTOR B BRACKET
MOTOR ROTOR
MOTOR STATOR
CONDENDER (STARTING)
AUTO-CUT (PROTECTOR)
CENTRIFUGAL SWITCH-1
CENTRIFUGAL SWITCH-2
SNAP RING
A PACKING
B PACKING
MOTOR A BEARING
MOTOR B BEARING
WAVE WASHER
*
*
*
*
*
*
*
*
606
1
1
1
*
607
*
608
*
A
MOTOR ASSEMBLY ..................... 1.................... INCLUDES ITEMS W/
*
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 39
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005SB — ELECTRIC MOTOR ASSY.
ST-2005SB ELECTRIC MOTOR ASSY.
PAGE 40 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ST-2005SB — ELECTRIC MOTOR ASSY.
ST-2005SB ELECTRIC MOTOR ASSY.
NO
PART NO
PART NAME
QTY.
1
1
1
4
4
1
1
1
1
1
1
1
1
1
1
REMARK
112
0201503A112
0202005A129
0202005A130
0202005A131
0201503A132
0201503A268
0202005A269
0202005A270
0202005A273
0202005A445
0202005A446
0201503A4471
0201503A4472
0202005T539
0201503A540
0201503A541
0202005T606
0202005S607
0202005T608
0202005SB119
OIL SEAL
*
129*
130*
131*
132*
268*
269
270
273
445
446
447-1
447-2
539
540*
541*
MOTOR HEAD COVER
PACKING
BOLT
SPRING WASHER
MOTOR A BRACKET
MOTOR B BRACKET
MOTOR ROTOR
MOTOR STATOR
CONDENDER (STARTING)
AUTO-CUT (PROTECTOR)
CENTRIFUGAL SWITCH-1
CENTRIFUGAL SWITCH-2
SNAP RING
A PACKING
B PACKING
MOTOR A BEARING
MOTOR B BEARING
WAVE WASHER
*
*
*
*
*
*
*
*
606
1
1
1
*
607
*
608
*
A
MOTOR ASSEMBLY ..................... 1.................... INCLUDES ITEMS W/
*
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 41
Download from Www.Somanuals.com. All Manuals Search And Download.
Effective: October 1, 2002
TERMS AND CONDITIONS OF SALE — PARTS
PAYMENT TERMS
5. Partsmustbeinnewandresalablecon- Multiquipreservestherighttoquoteandsell
dition,intheoriginalMultiquippackage(if directtoGovernmentagencies,andtoOriginal
any), and with Multiquip part numbers Equipment Manufacturer accounts who use
Terms of payment for parts are net 10 days.
FREIGHTPOLICY
clearlymarked.
our products as integral parts of their own
products.
All parts orders will be shipped collect or
prepaidwiththechargesaddedtotheinvoice.
All shipments are F.O.B. point of origin.
Multiquip’sresponsibilityceaseswhenasigned
manifesthasbeenobtainedfromthecarrier,
andanyclaimforshortageordamagemustbe
settledbetweentheconsigneeandthecarrier.
6. Thefollowingitemsarenotreturnable:
SPECIALEXPEDITINGSERVICE
a. Obsolete parts. (If an item is in the
price book and shows as being re- A$35.00surchargewillbeaddedtotheinvoice
placedbyanotheritem,itisobsolete.) forspecialhandlingincludingbusshipments,
insuredparcelpostorincaseswhereMultiquip
mustpersonallydeliverthepartstothecarrier.
(such as gaskets, seals, “O” rings,
b. Any parts with a limited shelf life
andotherrubberparts)thatwerepur- LIMITATIONSOFSELLER’SLIABILITY
MINIMUMORDER
chasedmorethansixmonthspriorto
thereturndate.
Multiquip shall not be liable hereunder for
damagesinexcessofthepurchasepriceofthe
The minimum charge for orders from Mul-
tiquipis$15.00net.Customerswillbeasked
for instructions regarding handling of orders
notmeetingthisrequirement.
c. Anylineitemwithanextendeddealer item with respect to which damages are
netpriceoflessthan$5.00.
claimed, and in no event shall Multiquip be
liable for loss of profit or good will or for any
otherspecial,consequentialorincidentaldam-
ages.
d. Special order items.
RETURNEDGOODSPOLICY
e. Electricalcomponents.
f. Paint,chemicals,andlubricants.
g. Decalsandpaperproducts.
h. Itemspurchasedinkits.
Returnshipmentswillbeacceptedandcredit
willbeallowed,subjecttothefollowingprovi-
sions:
LIMITATIONOFWARRANTIES
Nowarranties,expressorimplied,aremade
in connection with the sale of parts or trade
accessoriesnorastoanyenginenotmanufac-
tured by Multiquip. Such warranties made in
connectionwiththesaleofnew,completeunits
are made exclusively by a statement of war-
rantypackagedwithsuchunits,andMultiquip
neitherassumesnorauthorizesanypersonto
assume for it any other obligation or liability
whatever in connection with the sale of its
products.Apartfromsuchwrittenstatementof
warranty, there are no warranties, express,
impliedorstatutory,whichextendbeyondthe
descriptionoftheproductsonthefacehereof.
1. AReturnedMaterialAuthorizationmust
be approved by Multiquip prior to ship-
ment.
7. Thesenderwillbenotifiedofanymaterial
receivedthatisnotacceptable.
2. ToobtainaReturnMaterialAuthorization,
alistmustbeprovidedtoMultiquipParts
Salesthatdefinesitemnumbers,quanti-
ties, and descriptions of the items to be
returned.
8. Suchmaterialwillbeheldforfiveworking
days from notification, pending instruc-
tions.Ifareplyisnotreceivedwithinfive
days,thematerialwillbereturnedtothe
senderathisexpense.
a. Thepartsnumbersanddescriptions
must match the current parts price
list.
9. Creditonreturnedpartswillbeissuedat
dealer net price at time of the original
purchase,lessa15%restockingcharge.
b. The list must be typed or computer
generated.
10. In cases where an item is accepted, for
which the original purchase document
can not be determined, the price will be
basedonthelistpricethatwaseffective
twelvemonthspriortotheRMAdate.
c. The list must state the reason(s) for
thereturn.
d. The list must reference the sales
order(s)orinvoice(s)underwhichthe
itemswereoriginallypurchased.
11. Credit issued will be applied to future
purchasesonly.
e. The list must include the name and
phonenumberofthepersonrequest-
ingtheRMA.
PRICINGANDREBATES
Prices are subject to change without prior
notice.Pricechangesareeffectiveonaspe-
cificdateandallordersreceivedonorafterthat
datewillbebilledattherevisedprice.Rebates
3. AcopyoftheReturnMaterialAuthoriza-
tionmustaccompanythereturnshipment.
4. Freight is at the sender’s expense. All forpricedeclinesandaddedchargesforprice
partsmustbereturnedfreightprepaidto increaseswillnotbemadeforstockonhand
Multiquip’sdesignatedreceivingpoint.
atthetimeofanypricechange.
PAGE 42 — ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE PAGE
ST-2005 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #3 (09/21/04) — PAGE 43
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION AND PARTS MANUAL
HERE'S HOW TO GET HELP
PLEASE HAVETHE MODEL AND SERIAL
NUMBER ON-HANDWHEN CALLING
MULTIQUIP CORPORATE OFFICE
18910 Wilmington Ave.
Carson, CA 90746
800-421-1244
FAX:310-537-3927
Email: [email protected]
Internet:www.multiquip.com
PARTS DEPARTMENT
800-427-1244
310-537-3700
FAX:800-672-7877
FAX:310-637-3284
MAYCO PARTS
800-306-2926
310-537-3700
FAX:800-672-7877
FAX:310-637-3284
SERVICE DEPARTMENT
800-421-1244
FAX:310-537-4259
310-537-3700
TECHNICAL ASSISTANCE
800-478-1244
FAX:310-631-5032
FAX:310-537-1173
WARRANTYDEPARTMENT
800-421-1244,EXT.279
310-537-3700,EXT.279
Your Local Dealer is:
MULTIQUIP INC.
18910 WILMINGTONAVE.
CARSON, CALIFORNIA 90746
800-421-1244 • 310-537-3700
FAX:310-537-3927
E-mail:[email protected]
Internet:multiquip.com