OPERATION AND PARTS MANUAL
MODEL GA-2.9R
PORTABLE AC GENERATOR
(GASOLINE ENGINE)
Revision #0 (10/28/04)
THIS MANUAL MUST ACCOMPANY
THE EQUIPMENT AT ALLTIMES.
Download from Www.Somanuals.com. All Manuals Search And Download.
HERE'S HOW TO GET HELP
PLEASE HAVETHE MODEL AND SERIAL
NUMBER ON-HANDWHEN CALLING
MULTIQUIP CORPORATE OFFICE
18910 Wilmington Ave.
Carson, CA 90746
800-421-1244
FAX:310-537-3927
Email: [email protected]
Internet:www.multiquip.com
PARTS DEPARTMENT
800-427-1244
310-537-3700
FAX:800-672-7877
FAX:310-637-3284
MAYCO PARTS
800-306-2926
310-537-3700
FAX:800-672-7877
FAX:310-637-3284
SERVICE DEPARTMENT
800-421-1244
FAX:310-537-4259
310-537-3700
TECHNICAL ASSISTANCE
800-478-1244
FAX:310-631-5032
FAX:310-537-1173
WARRANTYDEPARTMENT
800-421-1244,EXT.279
310-537-3700,EXT.279
© COPYRIGHT 2004, MULTIQUIP INC.
Multiquip Inc, the MQ logo are registered trademarks of Multiquip Inc. and may not be used, reproduced, or altered without written
permission. All other trademarks are the property of thier respective owners and used with permission.
This manual MUST accompany the equipment at all times.This manual is considered a permanent part of the equipment and should
remain with the unit if resold.
The information and specifications included in this publication were in effect at the time of approval for printing. Illustrations are
based on the MQ GA-2.9R Portable Generator. Illustrations, descriptions, references and technical data contained in this manual
are for guidance only and may not be considered as binding. Multiquip Inc. reserves the right to discontinue or change specifications,
design or the information published in this publication at any time without notice and without incurring any obligations.
To find the latest revision of this
publication, visit our website at:
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 3
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
ROBIN EX170D20210
Engine (EPA)
MQ GA-2.9R — AC
Portable Generator
Crankcase Assembly .........................................42-43
Crankshaft, Piston Assembly .............................44-45
Governor Assembly ...........................................46-47
Intake and Exhaust Assembly............................48-49
Air Cleaner Assembly.........................................50-51
Cooling Starting Assembly.................................52-53
Carburetor Assembly .........................................54-55
Flywheel Assembly ............................................56-57
Electric Device Assembly ...................................58-59
Here's How To Get Help ............................................ 3
Table Of Contents ..................................................... 4
Parts Ordering Procedures ....................................... 5
Dimensions ............................................................... 6
Specifications ............................................................ 7
Safety Alert Message Symbols .............................. 8-9
Rules for Safe Operation ................................... 10-12
Operation and Safety Decals .................................. 13
General Information ................................................ 14
Load Application ..................................................... 15
Controls and Indicators ...................................... 16-17
Generator Refueling ............................................... 18
Installation .......................................................... 19-20
Pre-Inspection ......................................................... 21
Pre-Inspection (Engine) .......................................... 22
Initial Start-up (Engine) ........................................... 23
Initial Start-up (Engine/Operation).......................... 24
Preparation For Long Term Storage ....................... 25
Maintenance ...................................................... 26-27
Wiring Diagram ....................................................... 28
Troubleshooting (Engine)................................... 29-30
Troubleshooting (Generator) .................................. 31
Explanation Of Codes In Remarks Column ............ 32
Suggested Spare Parts ........................................... 33
Terms and Conditions Of Sale — Parts .................. 60
As a continuing effort to
update our parts book,
contact the MQ literature
department for the latest
revision of your "Operation
and Parts Manual"
Specification and part
number are subject to change
without notice.
Generator Component
Drawings
Nameplate and Decals....................................... 34-35
Generator Assembly .......................................... 36-37
Control Box Assembly ........................................ 38-39
Pipe Frame Assembly ........................................ 40-41
PAGE 4 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS ORDERING PROCEDURES
When ordering parts,
please supply the following information:
❒
❒
❒
❒
❒
❒
❒
Dealeraccountnumber
Dealernameandaddress
Shipping address (if different than billing address)
Returnfaxnumber
Applicable model number
Quantity,part number and description of each part
Specifypreferredmethodofshipment:
✓
✓
✓
✓
✓
✓
FedEx or UPS Ground
FedEx or UPS Second Day or Third Day
FedEx or UPS Next Day
Federal Express Priority One
DHL
Note:Unlessotherwiseindicatedbycustomer, all
orders are treated as “Standard Orders”, and will
ship within 24 hours.We will make every effort to ship
“Air Shipments” the same day that the order is
received, if prior to 2PM west coast time. “Stock
Orders” must be so noted on fax or web forms.
Truck
Place Your Parts Order Via Web or Fax
For Even More Savings!
Here’s how to get help...
Please have the model and serial number
on hand when calling.
(Domestic USA Dealers Only)
MULTIQUIP CORPORATE OFFICE
18910 Wilmington Ave.
Carson, CA 90746
Email: [email protected]
800-421-1244
FAX: 310-537-3927
Extra Discounts!
All parts orders which include complete part numbers and
are received by our automated web parts order system, or
by fax qualify for the following extra discounts:
Ordered
via
Standard
orders
Stock orders
PARTS DEPARTMENT
800-427-1244
310-537-3700
MAYCO PARTS
800-306-2926
310-537-3700
SERVICE DEPARTMENT
800-421-1244
310-537-3700
TECHNICAL ASSISTANCE
800-478-1244
WARRANTY DEPARTMENT
800-421-1244, EXT. 279
310-537-3700, EXT. 279
($750 list and above)
FAX: 800-672-7877
FAX: 310-637-3284
Fax
3%
5%
10%
10%
Web
FAX: 800-672-7877
FAX: 310-637-3284
Special freight allowances
when you order 10 or more
line items via Web or Fax!**
FedEx Ground Service at no charge for freight
No other allowances on freight shipped by any other carrier.
FAX: 310-537-4259
FAX: 310-631-5032
FAX: 310-537-1173
**Common nuts, bolts and washers (all items under $1.00
list price) do not count towards the 10+ line items.
NOTE:DISCOUNTSARESUBJECTTOCHANGE
MULTIQUIP INC.
Direct TOLL-FREE access
to our Parts Department:
18910WILMINGTON AVENUE
POST OFFICE BOX 6254
CARSON, CALIFORNIA 90749
310-537-3700 • 800-421-1244
FAX:310-537-3927
Toll-free nationwide — 800-427-1244
INTERNET:www.multiquip.com
Toll-free FAX — 800-6-PARTS-7 (800/672-7877)
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 5
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R— DIMENSIONS
Figure 1. Dimensions
PAGE 6 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R— SPECIFICATIONS
Table 1. Specifications
MODEL
GA-2.9R
Type
2-Pole, Brushless Type Revolving Field
Frequency (Hz)
60
2.6
Continuous Output (kW)
Maximum Output (kW)
Voltages (VAC)
2.9
120
Max/Continuous Amps 120 VAC
Rated Speed (RPM)
Power Factor
24.2/21.7
3600
1.0
GENERATOR
20 X 16 X18
(510 X 410 X 465)
Dimension (L x W x H) in. (mm)
Dry Net Weight lbs. (kg)
Includes Engine
108 (49)
Model
Type
ROBIN EX170D20210
Air-cooled, 4-stroke, Single Cylinder, Overhead
Camshaft, Gasoline Engine
Displacement (cc)
169
2.9 @3600
Continuous Output (kW/min)
Maximum Output (kW/min)
Fuel Tank Capacity Gal. (L)
Fuel
5.7 @4000
3.17 (12)
ENGINE
Non-leaded Automobile Gasoline
0.63 (0.6)
Lube Oil Capacity Qts. (L)
Speed Control Method
Starting Method
Centrifugal Fly-weight Type
Recoil Start
11.96 X 13.93 X 13.18
(304 X 354 X 335)
Dimension (L x W x H) in. (mm)
Dry Net Weight lbs. (kg)
33.06 (15)
Effects of Altitude and Heat
The maximum output of the engine listed above is applicable to supplying electrical power for continuous service at ambient
conditions in accordance with SAE Test cord J607. The above ambient conditions are at standard sea level, with a barometric
reading of 29.92 inches and a temperature of 60 degrees Fahrenheit.
Generally, the engine output power will decrease 3 1/2% for each 1000 feet of altitude above sea level, and 1% for each 10° F
fahrenheit above the standard temperature of 60° F.
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 7
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R— SAFETY MESSAGE ALERT SYMBOLS
HAZARD SYMBOLS
FORYOUR SAFETY ANDTHE SAFETY OF OTHERS!
Potential hazards associated with the operation of a MQ
GA-2.9R Portable Generator will be referenced with Hazard
Safety precautions should be followed
at all times when operating this
equipment. Failure to read and
understand the Safety Messages and
Operating Instructions could result in
injury to yourself and others.
Symbols which appear throughout this manual, and will be
Lethal Exhaust Gases
referenced in conjunction with Safety Message Alert
Symbols.
Lethal Exhaust Gas Hazards
WARNING
This Owner's Manual has been
developed to provide complete
instructions for the safe and efficient
Engine exhaust gases contain
poisonous carbon monoxide. This gas
is colorless and odorless, and can
cause death if inhaled. NEVER operate
this equipment in a confined area or
enclosed structure that does not provide
ample free flow air.
operation of the MQ Model GA-2.9R
Portable Generator. Refer to the
engine manufacturers instructions for
data relative to its safe operation.
Before using this generator, ensure that the operating
individual has read and understands all instructions in this
manual.
Explosive Fuel Hazards
SAFETY MESSAGE ALERT SYMBOLS
WARNING
Gasoline is extremely flammable, and
its vapors can cause an explosion if
ignited. DO NOT start the engine near
spilled fuel or combustible fluids.
The three (3) Safety Messages shown below will inform you
about potential hazards that could injure you or others. The
Safety Messages specifically address the level of exposure to
the operator, and are preceded by one of three words: DANGER,
DO NOT fill the fuel tank while the engine is running or
hot. DO NOT overfill tank, since spilled fuel could ignite if
it comes into contact with hot engine parts or sparks from
the ignition system. Store fuel in approved containers, in
well-ventilated areas and away from sparks and flames.
DANGER
You WILL be KILLED or SERIOUSLY INJURED
if you DO NOT follow these directions.
Burn Hazards
WARNING
WARNING
Engine components can generate extreme
heat. To prevent burns, DO NOT touch
these areas while the engine is running or
immediately after operations. Never
operate the engine with heat shields or heat
guards removed.
You CAN be KILLED or SERIOUSLY INJURED if
you DO NOT follow these directions.
CAUTION
You CAN be INJURED if you DO NOT follow
these directions.
Respiratory Hazards
WARNING
ALWAYS wear approved respiratory
protection when required.
PAGE 8 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R— SAFETY MESSAGE ALERT SYMBOLS
Equipment Damage
Rotating Parts Hazards
CAUTION
CAUTION
Hazards
NEVER operate equipment with covers,
or guards removed. Keep fingers, hands,
hair and clothing away from all moving
parts to prevent injury.
Other important messages are provided throughout this
manual to help prevent damage to your portable generator,
other property, or the surrounding environment.
Accidental Starting Hazards
CAUTION
ALWAYS place the power source, circuit
breakers or ON/OFF switch in the OFF
position, when the generator is not in use,
unless connected to transfer switch.
Eye and Hearing Hazards
CAUTION
ALWAYS wear approved eye and
hearing protection.
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 9
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R— RULES FOR SAFE OPERATION
■
NEVER touch the hot exhaust
manifold, muffler or cylinder. Allow
these parts to cool before servicing
engine or generator.
Read this manual!
DANGER
Failure to follow instructions in this manual may lead
to serious injury or even death! This equipment is to
be operated by trained and qualified personnel only!
This equipment is for industrial use only.
The following safety guidelines should always be used when
operating the MQ GA-2.9R Portable Generator:
■
The engine section of this generator requires an adequate
free flow of cooling air. NEVER operate the generator in
any enclosed or narrow
area where free flow of
the air is restricted. If the
GENERAL SAFETY
■
DO NOT operate or service this
equipment before reading this entire
manual.
air flow is restricted it will
cause serious damage to
the generator or engine
and may cause injury to
people. Remember the
generator's engine gives
off DEADLY carbon
■
■
This equipment should not be operated by persons under
18 years of age.
NEVER operate this equipment without proper protective
clothing, shatterproof glasses, steel-toed boots and other
protective devices required by the job.
monoxide gas.
■
■
ALWAYS refuel in a well-ventilated area, away from sparks
and open flames.
■
■
NEVER operate this equipment when not
feeling well due to fatigue, illness or taking
medicine.
ALWAYS use extreme caution when
working with flammable liquids. When
refueling, stop the engine and allow it to
cool.DO NOT smoke around or near the
machine. Fire or explosion could result
from fuel vapors, or if fuel is spilled on a
hot engine.
NEVER operate this equipment under the influence of
drugs or alcohol.
■
NEVER operate the generator in an
explosive atmosphere or near
combustible materials. An explosion or
fire could result causing severe bodily
harm or even death.
■
ALWAYS wear proper respiratory (mask),
hearing and eye protection equipment when
operating the generator.
■
■
■
Whenever necessary, replace nameplate, operation and
safety decals when they become difficult read.
■
NEVER disconnect any "emergency or safety devices".
These devices are intended for operator safety. Disconnection
of these devices can cause severe injury, bodily harm or even
death! Disconnection of any of these devices will void all
warranties.
Manufacturer does not assume responsibility for any
accident due to equipment modifications.
NEVER use accessories or attachments, which are not
recommended by Multiquip for this equipment. Damage
to the equipment and/or injury to user may result.
PAGE 10 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — RULES FOR SAFE OPERATION
■
■
■
ALWAYS be sure the operator is familiar with proper safety
precautions and operation techniques before using generator.
Maintenance Safety
■
NEVER lubricate components or attempt service on a running
machine.
NEVER leave the generator unattended, turn off engine when
unattended.
■
HighTemperatures – Always stop engine and
allow the engine to cool before adding fuel, oil
or performing service and maintenance
functions. Contact with hot! components can
cause serious burns.
Unauthorized equipment modifications will void all
warranties.
■
■
ALWAYS ensure generator is on level ground before use.
DO NOT place hands or fingers inside generator engine
compartment when engine is running.
■
■
Keep the machinery in proper running condition.
Fix damage to the machine immediately and replace any
broken parts immediately.
■
■
NEVER run engine without air cleaner.Severe engine damage
may occur.
■
■
ALWAYS replace any worn or damaged warning decals.
NEVER change or adjust the engine speed which has been
set at the factory prior to shipping.
ALWAYS store equipment properly when it is not being used.
Equipment should be stored in a clean, dry location out of the
reach of children and un-authorized personnel.
Power Cord Safety
■
NEVER let power cables or cords lay in water.
■
The electrical voltage required to operate the generator can
cause severe injury or even death through physical contact
with live circuits. Turn all circuit breakers OFF before
performing maintenance on the generator.
■
NEVER stand in water while AC power from the generator
is being transfer to a load.
■
■
■
NEVER use a defective or frayed power cable. Check the
cable for cuts in the insulation.
■
■
■
Dispose of hazardous waste properly.Examples of potentially
hazardous waste are used motor oil, fuel and fuel filters.
NEVER use a extension cord that is frayed or damaged where
the insulation has been cut.
DO NOT use food or plastic containers to dispose of
hazardous waste.
ALWAYS make certain that proper power or extension cord
has been selected for the job See Table 3.
DO NOT pour waste, oil or fuel directly onto the ground,
down a drain or into any water source.
Grounding Safety
■
Removing the engine oil drain plug while
the engine is hot will result in hot oil to gush
out of the oil drain plug, therefore causing
severescaldingtoanypersonsinthegeneral
area of the generator.
■
ALWAYS make sure that electrical circuits are properly
grounded per the National Electrical Code (NEC) and
local codes before operating generator. Severe injury or
death! by electrocution can result from operating an
ungrounded generator.
■
■
ALWAYS make sure generator is properly grounded to a
suitable earth ground (GROUND ROD). See installation in
this manual.
NEVER use gas piping as an electrical ground.
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 11
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — RULES FOR SAFE OPERATION
Emergencies
DANGER-ELECTROCUTION HAZARDS
■
ALWAYS know the location of the
nearest fire extinguisher.
During operation of this generation, there
exists the possibility of electrocution,
electrical shock or burn, which can
cause severe bodily harm or even
DEATH!
■
■
ALWAYS know the location of the nearest
first aid kit.
To avoid these hazards:
NEVER use damaged or worn cables when connecting
equipment to the generator.Make sure power connecting
cables are securely connected to the generator’s output
receptacles, incorrect connections may cause damage
to the generator and electrical shock.
In emergencies always know the location of the
nearest phone or keep a phone on the job site.
Also know the phone numbers of the nearest
ambulance, doctor and fire department. This
information will be invaluable in the case of an
emergency.
NEVER grab or touch a live
power cord with wet hands, the
possibility exist of electrical
shock, electrocution, and even
death!
NEVER insert any objects into
the output receptacles during
operation. This is extremely
dangerous. ALWAYS turn-off
the generator and place all circuit breakers in the “OFF”
position when contact with the output receptacles is
required. There exist the possibility of electrocution,
electrical shock or burn, which can cause severe
bodily harm or even death!
Backfeed to a utility system can cause
electrocution and or property damage.
NEVER connect the generator to a
building's electrical system without a
transfer switch or other approved device.
All installations should be performed by
a licensed electrician in accordance
with all applicable laws and electrical
codes. Failure to do so could result in
electrical shock or burn causing serious
injury or even death!
PAGE 12 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — OPERATION AND SAFETY DECALS
Machine Safety Decals
The MQ GA-2.9R portable generator is equipped with a number of safety decals (Figure 2). These decals are provided for operator
safety and maintenance information.The illustration below shows these decals as they appear on the machine.Should any of these
decals become unreadable, replacements can be obtained from your dealer.
Figure 2. Operation and Safety Decals
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 13
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — GENERAL INFORMATION
Excitation System
MQ GA-2.9R Familarization
The MQ GA-2.9R generator uses a magnet attached to a
flywheel to produce AC voltage from a lamp coil beneath
the flywheel. As the magnet passes the coil it produces
approximately 19-22 AC volts.
General Inspection Prior to Operation
This generator has been thoroughly inspected and accepted
prior to shipment from the factory.However, be sure to check
for damaged parts or components, or loose nuts and bolts,
which could have become disloged in transit.
This voltage (19-22 VAC) is then sent to the control box that
contains three rectifying diodes:
The MQ Model GA-2.9R generator has been designed as a
portable lightweight power source for 60 Hz (single-phase)
vibrators, lighting facilities, power tools, submersible pumps
and other industrial and construction machinery.
z
z
z
Excitation (diode 1)
Battery (diode 2)
Slow Down (diode 3)
This generator is powered by a 5.7 HP ROBIN air-cooled
gasoline engine. The alternator, a brushless revolving-field
type, is permanently aligned to the engine through rigid
coupling.
The AC voltage will pass through the excitation diode that
converts the voltage to DC power.
This DC power is then sent to the excitation windings housed
within the main windings commonly called the "stator".
The generator is mounted on rubber vibration isolators that
have a steel base backplate which is attached to the
protective steel pipe carrying frame.The protective carrying
frame is made of steel tubing and fully wraps around the
generator to protect against damage.
This voltage is then transferred into the rotor through
induction.The rotor contains two diodes within it which rectify
the DC voltage and send it out through the main windings,
as AC voltage.
Engine
This portable generator is supplied with a electrical control
panel. The control panel includes items as listed below.
The four-cycle air-cooled ROBIN gasoline engine is designed
to meet every performance requirement of this generator.
Reference Table 1, for engine specifications.
Control Panel
The generator control panel has the following componets:
Figure 3 shows the basic controls and indicators for the
MQ GA-2.9R generator.
■
■
■
■
■
■
NEMA 5-20R, GFCI duplex receptacle, (120V, 20 amps)
NEMA L5-20R, twist-lock receptacle, (120V, 20 amps)
Circuit breaker, single-pole, 22 amps
ACVoltmeter
WARNING
Before connecting this generator to any building’s
electrical system, a licensed electrician must install an
isolation (transfer) switch.
Engine ON/OFF Switch
Ground Terminal
Serious injury or death may result without this transfer
switch. Please note that the transfer switch can only be
configured with generators that have electric start
capability.Transfer switch should not be used with recoil-
start type generators.
Circuit Breaker
To protect the generator from an overload, a single-pole, 22
amp circuit breaker is provided on the control panel. Make
sure to switch this circuit breaker to the "OFF" position prior
to starting the engine.
In keeping with Multiquip's
policy of constantly improving
its products, the specifications
quoted herein are subject to
change without prior notice.
PAGE 14 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R— LOAD APPLICATION
To determine the running wattage for your load, multiply
the running wattage as indicated by steps 1, 2, and 3 below:
Single Phase Load
Always be sure to check the nameplate on the generator
and equipment to insure the wattage, amperage and
frequency requirements are satisfactorily supplied by the
generator for operating the equipment.
1. INCANDESCENT LOADS
Lights, heaters and similar appliances.
Total the running wattage and multiply by 1.
Example:
Generally, the wattage listed on the nameplate of the
equipment is its rated output. Equipment may require 130—
150% more wattage than the rating on the nameplate, as
the wattage is influenced by the efficiency, power factor and
starting system of the equipment.
29 light bulbs @ 100W each = 2.9 KW
use a 3 KW generator.
2. SMALL MOTORS
Drills and other small power tools.
Total the running wattage and multiply by 2.
Example:
A 1 inch drill runs at 1 KW
use a 2 KW generator.
If wattage is not given on the equipment's
name plate, approximate wattage may be
determined by multiplying nameplate
voltage by the nameplate amperage.
3. LARGE MOTORS
Submersible pumps, table saws etc.
Total the running wattage and multiply by 3.
Example:
A conveyor belt runs at 8 KW
use a 24 KW generator.
WATTS = VOLTAGE x AMPERAGE
The power factor of this generator is 1.0 See Table 2 below
when connecting loads.
Table 2. Power Factor By Load
CAUTION
Type Of Load
Power Factor
Motors and motor-driven equipment draw much greater
current for starting than during operation.Always use an
adequate size extension cable which can carry the
required load.
Single-phase induction motors
0.4 - 0.75
Electric heaters, incandescent
lamps
1.0
Fluorescent lamps, mecury
lamps
Extension Cables
0.4 - 0.9
When electric power is to be provided to various tools or
loads at some distance from the generator, extension cords
are normally used. Cables should be sized to allow for
distance in length and amperage so that the voltage drop
between the generator and point of use (load) is held to
a minimum. Use the cable selection chart (Table 3 ) as a
guide for selecting proper cable size.
Electronic devices,
communication equipment
1.0
0.8
Common power tools
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 15
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — CONTROLS AND INDICATORS
Figure 2. Generator Controls and Components
PAGE 16 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — CONTROLS AND INDICATORS
1. 120V Output Receptacle – This NEMA L5-20R twist-
WARNING
lock receptacle will provide 120V, 20 amps, 60 Hz.
2. GFCI Receptacle – This receptacle will provide 120V at
ALWAYS allow time for the generator to cool
down before performing maintenance.
all times.
3. AC-Voltmeter – This voltmeter indicates (with a mark) the
rated 60 Hz, single phase output voltage. In addition the
voltmeter can also be used as a diagnostic tool. If the
voltmeter indicator (needle) is below the rated voltage,
engine problems may exist (low/high RPM's). To prevent
damage to the generator or power tools turn the generator
OFF and consult your authorized MQ service dealer.
11. Oil Drain Plug – Remove this plug to drain engine oil from
the crankcase.
12. Carburetor Fuel Cup – Inspect the fuel cup weekly for
water and dirt. Clean as referenced in the maintenance
section of this manual.
4. Main Circuit Breaker – This single-pole 22 amp breaker
protects the generator from short circuiting or overloading.
When starting the generator always have the circuit breaker
placed in the "OFF" position.
13. Choke Lever – Used for starting the engine. Close the
choke lever when starting a cold engine or in cold weather
conditions.The choke enriches the fuel mixture.Open the
choke lever if starting a warm engine or in warm weather
conditions.
5. Ground – This ground connection point should be
connect to a good earth ground (ground rod).
14. Fuel Cock Lever – Turn this lever downward to start
(down)the flow of fuel to the carburetor. Turn upward to
stop (up) the flow of fuel.
This ROBIN engine is equipped
15. Throttle Lever – Used to adjust engine RPM speed.This
with a low oil shutdown capability.A
built in sensor will automatically turn
off the engine should the oil level
fall below a safe operating condition.
unit is set at the factory and is not adjustable.
16. Recoil Starter (Pull Rope) – Used for manual-starting of
the engine. Pull the starter grip until resistance is felt, then
pull briskly and smoothly.
Make sure the generator is placed on level ground. Placing the
generator on level ground will ensure that the low oil sensor will
function properly.
17. Engine – This generator uses a 5.1 HP ROBIN air-
cooled, 4-stroke , single cylinder, overhead camshaft
gasoline engine. Engine uses unleaded fuel.
6. Operation/ON-OFF Switches – Place engine ON/OFF
switch in the "ON" position for normal operation. To turn-
off the generator place switch in the "OFF" position.
18. Air Cleaner – Prevents dirt and other debris from entering
the fuel system. Remove wing-nut on top of air filter
cannister to gain access to filter element. NEVER run the
engine without an air cleaner.
7. Generator Housing – Contains the rotor, rectifer field
coil assembly, aramature, bearings and other components
that make up generator asembly.
19. Fuel Gauge – Read this gauge to determine when fuel is
low.
8. Spark Plug – Provides spark to the ignition system. Set
spark plug gap to 0.6 - 0.7 mm (0.024 - 0.028 inch). Clean
spark plug once a week.
20. Fuel Gauge/Tank – Remove this cap to add unleaded
gasoline to the fuel tank. Replenish with clean unleaded
gasoline. Make sure cap is tightened securely. DO NOT
over fill. Fuel tank capacity is 3.17 gallons (12 liters).
9. Muffler/Heat Shield – Used to reduce noise and emissions.
NEVER touch this heat shield when the generator is in
use. Always allow time for the generator to cool down before
performing maintenance.
21. Lifting Bail Eye – Attach a rope or chain to this lifting eye
when lifting of the generator is required. Never stand
underneath the generator while it is being lifted. Place lifting
eye in down position when not in use.
10. Oil Dipstick/ Filler Cap– Remove the filler cap dipstick
when checking the engine oil level. Add engine oil through
this filler port. See Table 4 for recommended type engine
oil.
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 17
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — GENERATOR REFUELING
DANGER
Adding fuel to the tank should be done only when
the engine is stopped and has had an opportunity
to cool down. In the event of a fuel spill, DO NOTattempt to start
the engine until the fuel residue has been completely wiped up,
and the area surrounding the engine is dry. If generator is placed
in a truck bed with a plastic liner, REMOVE generator from truck
bed and place on ground (Figure 4) to refuel. This possibility
exist of fire or explosion due to static electricity.
Figure 4. Generator Refueling
PAGE 18 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — INSTALLATION
Outdoor Installation
Indoor Installation
Install the generator in a area that is free of debris,
bystanders, and overhead obstructions. Make sure the
generator is on secure level ground so that it cannot slide or
shift around. Also install the generator in a manner so that
the exhaust will not be discharged in the direction of nearby
homes.
Exhaust gases from gasoline engines are extremely
poisonous. Whenever an engine is installed indoors the
exhaust fumes must be vented to the outside. The engine
should be installed at least two feet from any outside wall.
Using an exhaust pipe which is too long or too small can
cause excessive back pressure which will cause the engine
to heat excessively and possibly burn the valves.
Eliminate the danger of deadly carbon monoxide gas.
Remember that exhaust fumes from any gasoline engine
are very poisonous if discharged in a closed room, but
harmless if allowed to mix with the outside air.If the generator
is installed indoors, you must make provisions for venting
the engine exhaust to the outside of the building.
The installation site must be relatively free from moisture
and dust. All electrical equipment should be protected from
excessive moisture. Failure to do will result in deterioration
of the insulation and will result in short circuits and grounding.
Foreign materials such as dust, sand, lint and abrasive
materials have a tendency to cause excessive wear to
engine and alternator parts.
Generator Grounding
To guard against electrical shock and possible damage to
the equipment, it is important to provide a good EARTH
ground. Always use the ground terminal on the generator to
ground the generator.
CAUTION
Article 250 (Grounding) of the National Electrical Code (NEC)
provides guide lines for proper grounding and specifies that
the cable ground shall be connected to the grounding system
of the building as close to the point of cable entry as
practical.
Pay close attention to ventilation when
operating the generator inside tunnels and
caves. The engine exhaust contains
noxious elements.
NEC articles 250-64(b) and 250-66 set the following
grounding requirements:
Mounting
The generator should always be mounted on a flat level
surface to isolate vibration of the generator when it is
running. DO NOT place the generator on slopes, the
possibility exists that the generator could slide.
1. Use one of the following wire types to connect the
generator to earth ground.
a. Copper - 10 AWG (5.3 mm2) or larger.
b. Aluminum - 8 AWG (8.4 mm2) or larger.
2. When grounding the generator (Figure 3) connect the
ground cable between the lock washer and the nut on
the generator and tighten the nut fully.Connect the other
end of the ground cable to earth ground.
3. NEC article 250-52(c) specifies that the earth ground
rod should be buried a minimum of 8 ft. into the ground.
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 19
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — INSTALLATION
Connecting the Ground
The nut and ground terminal on the generator should always be used to connect the generator to a suitable ground. The
ground cable should be #8 size wire minimum.
At the generator, connect the terminal of the ground cable between the lock washer and the nut (Figure 5) and tighten the
nut fully. Connect the other end of the ground cable to a suitable earth ground (ground rod).
Figure 5. Generator Grounding
PAGE 20 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R— PRE-INSPECTION
General Inspection Prior to Operation
Ground Power Tools
Extension Cable
When electric power is to be provided to various tools or loads at
some distance from the generator, extension cords are normally
used. Cables should be sized to allow for distance in length and
amperage so that the voltage drop between the generator and
point of use (load) is held to a minimum. Use the cable selection
chart (Table 3) as a guide for selecting proper cable size.
When using power tools or electrical equipment requireing AC
power from the generator, make sure connecting (power tool)
cable (Figure 6) has a ground as shown in Figure.
Never! use power tools or
equipment that do not have a
ground capability, the possibility
exists of electrocution, electrical
shock or burn, which can cause
severe bodily harm or even
DEATH!
Main Circuit Breaker
To protect the generator from an overload always place the main
circuit breaker in the "OFF" position prior to starting the engine.
Figure 6. Ground Cables/Plugs
Table 3. Cable Selection (60 Hz, Single Phase Operation)
Load In Watts
At 120 Volts
300
Maximum Allowable Cable Length
Current in
Amperes
#10 Wire
1000 ft.
500 ft.
350 ft.
250 ft.
150 ft.
125 ft.
#12 Wire
600 ft.
300 ft.
200 ft.
150 ft.
100 ft.
75 ft.
#14 Wire
375 ft.
200 ft.
125 ft.
100 ft.
65 ft.
#16 Wire
250 ft.
2.5
5
600
125 ft.
7.5
10
15
20
900
100 ft.
1200
1800
2400
50 ft.
CAUTION: Equipment damage can result from low voltage.
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 21
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — PRE-INSPECTION (ENGINE)
CAUTION
NEVER operate the generator in a confined
area or enclosed area structure that does
not provide ample free flow of air.
Figure 8. Engine Oil Dipstick (Oil Level)
Table 4. Oil Type
ALWAYS wear approved eye and hearing
protection before operating the generator.
Season
Summer
Spring/Fall
Winter
Temperature
25°C or Higher
25°C~10°C
Oil Type
SAE 10W-30
SAE 10W-30/20
SAE 10W-10
Before Starting
1.
Read safety instructions at the
beginning of manual.
0°C or Lower
2.
Clean the generator, removing dirt
and dust, particularly the engine
cooling air inlet, carburetor and air
cleaner.
DANGER EXPLOSIVE FUEL
3.
4.
5.
Check the air filter for dirt and dust. If air filter is dirty, replace
air filter with a new one as required.
Motor fuels are highly flammable and can be
dangerous if mishandled. DO NOT smoke
while refueling. DO NOT attempt to refuel the
generator if the engine is hot! , running or in
the dark.
Check carburetor for external dirt and dust. Clean with dry
compressed air.
Check fastening nuts and bolts for tightness.
Engine Oil Check
1.
To check the engine oil level, place the generator on secure
level ground with the engine stopped.
Fuel Check
1. Close the fuel cock before filling the fuel tank.
2. Remove the fuel cap located on top of fuel tank.
2.
Remove the filler dipstick from the engine oil filler hole
(Figure 7) and wipe clean.
3. Readthefuelgaugelocatedontopofthefueltank(Figure9)to
determin if the fuel level is low. If fuel is low, replenish with
clean unleaded fuel.
Figure 9. Fuel Gauge
Figure 7. Engine Oil Dipstick (Removal)
3. Insertandremovethedipstickwithoutscrewingitintothefiller
neck. Check the oil level shown on the dipstick.
4. When refueling, be sure to use a strainer for filtration. DO
NOT top-off fuel. DO NOT fill the tank beyond capacity.
Wipe up any spilled fuel immediately!
4. If the oil level is low (Figure 8), fill to the edge of the oil filler
holewiththerecommendedoiltype(Table4).Maximum oil
capacity is .63 quarts (0.6 liters)
PAGE 22 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — INITIAL START-UP (ENGINE)
3. Place the choke lever (Figure 12) in the "OPEN " position
CAUTION
if starting a warm engine or the temperature is warm.
DO NOT attempt to operate this
generator until the Safety, General
Information and Inspection sections
of this manual have been read and
thoroughly understood.
4. Place the engine ON/OFF switch (Figure 13) in the "ON "
position.
This section is intended to assist the
operator with the initial start-up of the trash generator. It is
extremely important that this section be read carefully before
attempting to use the generator in the field.
Before Starting the Engine
Figure 13. Engine ON/OFF Switch (ON)
1. Be sure to disconnect all electrical loads from the
generator prior to starting the engine.
5. Grasp the starter grip (Figure 14) and slowly pull it out.The
resistancebecomesthehardestatacertainposition,corre-
spondingtothecompressionpoint.Pullthestartergripbriskly
andsmoothlyforstarting.
2. NEVER start the engine with the main circuit breaker
in the “ON" position. Place the main circuit breaker
(Figure 10) in the OFF position.
Figure 10. Main Breaker (OFF Position)
Starting the Engine
1. Place the engine fuel valve lever (Figure 11) to the "ON"
Figure 14. Starter Grip
position.
”
CAUTION
DO NOT pull the starter rope all the way to the end.
DO NOT release the starter knob after pulling. Allow it to
rewind as soon as possible.
Figure 11. Engine FuelValve Lever (ON Position)
2. Placethechokelever(Figure12)inthe"CLOSED"position
if starting a cold engine.
Figure 12. Choke Lever
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 23
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R— INITIAL START-UP ENGINE/OPERATION
Stopping The Engine
6. If the engine has started, slowly return the choke lever
(Figure 12 ) to the “OPEN” position. If the engine has not
started repeat steps 1 through 5.
Normal Shutdown
1. Place the main circuit breaker (Figure 10) in the OFF
position.
7. Beforethegeneratorisplacedintooperation,runtheengine
for3-5minutes. Checkfor abnormalsmells,fuelleaks, and
noises that would associate with lose components.
2. Remove the load from the generator, and let the engine
run at idle for 3-5 minutes with the idle control switch in
the ON position (Up)
8. Refer to the AC voltmeter (Figure 15) on the control
box. The voltage indicated on the voltmeter should be
120 VAC with no load applied.
5. Place the engine ON/OFF switch (Figure 18) in the "OFF"
position.
Figure 15. AC Voltmeter (120VAC)
Figure 18. Engine ON/OFF Switch (OFF)
11. If desired, verify with a voltmeter (Figure16) that 120
VAC is present at the GFCI duplex receptacle and the
120V twist-lock receptacle.
6. Place the engine fuel valve lever (Figure 19) to the "OFF"
position.
”
Figure 19. Engine Fuel Valve Lever (OFF Position)
Emergency Showdown
1. Place the engine ON/OFF swith (Figure 18) in the
"OFF" position.
Figure 16. 120VAC GFCI Receptacle
Connecting the Load
1. Connect the load to the output receptacles.
2. Place the main circuit breaker (Figure 17) in the ON
position.
Figure 17. Main Circuit Breaker (ON)
PAGE 24 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — PREPARATION FOR LONG -TERM STORAGE
Generator Storage
For storage of the generating set for over 30 days, the
following is required:
■
■
Drain the fuel tank completely, or add STA-BIL to the fuel.
Run the engine until the gasoline in the carburetor is
completely consumed.
■
■
■
■
Completely drain the oil from the crankcase and refill with
fresh oil.
Remove the spark plug, pour 2 or 3 cc of SAE 30 oil into the
cylinder and crank slowly to distribute the oil.
Slowly rotate the engine a few times with the starter Rope and
install a new plug.
Pull out the starter rope slowly and stop at the compression
point.
■
■
Clean all external parts of the generating set with a cloth.
Cover the generating set and store in a clean, dry place.
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 25
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — MAINTENANCE (ENGINE)
UseTable 5 as a general maintenance guideline when servicing
your engine. For more detail engine maintenance information,
refer to the engine owner's manual supplied with your engine.
Table 5. Engine Maintenance Schedule
FIRST
EVERY
EVERY
EVERY
YEAR
OR
EVERY
2 YEARS
OR
MONTH 3 MONTHS 6 MONTHS
OR
DESCRIPTION (3)
OPERATION
BEFORE
OR
OR
10 HRS.
25 HRS.
50 HRS.
100 HRS.
200 HRS.
CHECK
CHANGE
CHECK
X
Engine Oil
X
X
X
Air Cleaner
All Nuts & Bolts
Spark Plug
CHANGE
X (1)
Re-tighten If
Necessary
CHECK-CLEAN
REPLACE
CHECK
X
X
X
Cooling Fins
Spark Arrester
Fuel Tank
CLEAN
X
X
CLEAN
Fuel Filter
CHECK
X
Idle Speed
CHECK-ADJUST
CHECK-ADJUST
CHECK
X (2)
Valve Clearance
Fuel lines
X (2)
Every 2 years (replace if necessary) (2)
(1) Service more frequently when used in DUSTY areas.
(2) These items should be serviced by your service dealer, unless you have the proper tools and are mechanically
proficient. Refer to the ROBIN Shop Manual for service procedures.
(3) For commercial use, log hours of operation to determine proper maintenance intervals.
PAGE 26 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — MAINTENANCE (ENGINE)
Maintenance
Cleaning the Fuel Strainer
Perform the scheduled maintenance procedures as defined by
Table 6 and below:
Clean the fuel strainer if it contains dust or water. Remove
dust or water in the strainer cap and wash it in gasoline.
Securely fasten the fuel strainer cap so that fuel will not
leak. Check the fuel strainer every 200 hours of operation or
once a month.
DAILY
■
Thoroughly remove dirt and oil from the engine and control
area.Clean or replace the air cleaner elements as necessary.
Check and retighten all fasteners as necessary. Check the
gearbox for oil leaks. Repair or replace as needed.
DANGER
DO NOT use gasoline as a cleaning solvent,
because that would create a risk of fire or
explosion.
WEEKLY
■
Remove the fuel filter cap and clean the inside of the fuel
tank.
■
■
Remove or clean the filter at the bottom of the tank.
ENGINEAIRCLEANER
Remove and clean the spark plug (Figure 20), then adjust
the spark gap to 0.024 ~0.028 inch (0.6~0.7 mm).This unit
has electronic ignition, which requires no adjustments.
1. Remove the air cleaner cover and foam filter element as
shown in Figure 22.
2. Tap the paper filter element (Figure 22) several times on a
hard surface to remove dirt, or blow compressed air [not
exceeding 30 psi (207 kPa, 2.1 kgf/cm2)] through the filter
elementfromtheaircleanercaseside.NEVER brushoffdirt.
Brushingwillforcedirtintothefibers.Replacethepaperfilter
element if it is excessively dirty.
Figure 20. Spark Plug Gap
ENGINEOIL
1. Drain the engine oil when the oil is warm as shown in
Figure 21.
2. Remove the oil drain bolt and sealing washer and allow
the oil to drain into a suitable container.
3. Replace engine oil with recommended type oil as listed
in Table 4. For engine oil capacity, see Table 1 (engine
specifications). DO NOT overfill.
4. Install drain bolt with sealing washer and tighten se-
curely.
Figure 22. Engine Air Cleaner
Figure 21. Engine Oil (Draining)
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 27
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R —WIRING DIAGRAM
Figure 23. Generator/Engine Wiring Diagram
PAGE 28 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R —TROUBLESHOOTING (ENGINE)
diagnosis based on the Engine Troubleshooting (Table 6)
information shown below and on the proceeding page. If the
problem cannot be remedied, please leave the unit just as it
is and consult our company's business office or service
plant.
Practically all breakdowns can be prevented by proper
handling and maintenance inspections, but in the event of a
breakdown, please take a remedial action following the
TABLE 6. ENGINE TROUBLESHOOTING
SYMPTOM
POSSIBLE PROBLEM
SOLUTION
Inspect carburetor to see if fuel
is reaching it?
Check fuel line
No Fuel?
Add Fuel
Water in fuel tank?
Fuel filter clogged?
Stuck carburetor?
Spark plug is red?
Flush or replace fuel tank.
Replace fuel filter
Check float mechanism.
Poor starting
Spark plug is fouled. Check tranistor ignition unit.
Insufficient compression, injected air leaking. Carburetor jets are
clogged (overflow).
Spark plug is blue-white?
No spark present at tip of spark
plug?
Tranistor ignition unit broken, high voltage cord cracked or broken.
Start/Stop switch broken. Replace spark plug if fouled.
No oil?
Add oil as required.
Oil pressure alarm lamp blinks
upon starting?
Check Automatic shutdown circuit "oil sensor".
Replace cylinder and piston and if necessary axel joint.
Tighten cylinder head connecting bolts.
Engine will not turn over?
Cylinder head connecting bolts
loose?
Cylinder head gasket damaged? Replace cylinder head gasket.
Insufficient power output "no
compression"
Malfunction of valve seat?
Spark plug is loose?
Worn piston rings?
Re-seat valves.
Replace spark plug.
Replace piston rings.
Malfunction in air-cleaner
system, air filter clogged?
Clean or replace air filter.
Air leaking in from interface
between carburetor and cylinder
head?
Tighten bolts between carburetor and cylinder head. Replace
cylinder head gasket.
Insufficient power output
"compression"
Clean or replace fuel filter.
Clean or replace carburetor.
Check carburetor float.
Malfunction in fuel system?
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 29
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R —TROUBLESHOOTING (ENGINE)
TABLE 6. ENGINE TROUBLESHOOTING (CONTINUED)
SYMPTOM
POSSIBLE PROBLEM
Malfunction in blower?
SOLUTION
Check or replace blower.
Insufficient power output
"compression" and overheats
Air in-take filter clogged?
Clean or replace air in-take filter.
Over accumulation of exhaust
products?
Clean and check valves.
Check muffler, replace if necessary.
Burns to much fuel
Wrong spark plug?
Replace spark plug with manufactures suggested type spark plug.
Replace lubricating oil with correct viscosity.
Replace rings
Lubricating oil is wrong
viscosity?
Exhaust color is continiously
"WHITE"
Worn rings?
Air cleanner clogged?
Clean or replace air cleaner.
Choke valve has not been set
to the correct position?
Adjust choke valve to the correct position.
Exhaust color is continiously
"BLACK"
Carburetor defective, seal on
carburetor broken?
Replace carburetor or seal.
Adjust carburetor.
Poor carburetor adjustment
"engine runs too rich?
PAGE 30 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R —TROUBLESHOOTING (GENERATOR)
diagnosis based on the GeneratorTroubleshooting (Table 7)
information shown below and on the preceding page. If the
problem cannot be remedied, please leave the unit just as it
is and consult our company's business office or service
plant.
Practically all generator breakdowns can be prevented by
proper handling and maintenance inspections, but in the event
of a breakdown, please take a remedial action following the
TABLE 7. GENERATOR TROUBLESHOOTING
SYMPTOM
Low voltage
POSSIBLE PROBLEM
Engine speed too low?
SOLUTION
Raise engine speed to rated RPM.
AC voltmeter not working?
Replace AC voltmeter.
Control box internal wiring
malfunction?
Check control box wiring.
Defective ignition coil?
Check red and green ignition wires. Replace ignition wires if
necessary.
Low voltage. Engine speed
normal 3650 RPM (unloaded),
2500 RPM (idle)
Rotor winding malfunction?
Stator winding malfunction?
Breaker malfunction?
Check or replace rotor.
Check or replace stator.
Check or replace CB1.
Voltage output too high.
Engine speed too high?
Lower engine speed to rated RPM.
Check control box wiring.
Voltage output too high. Engine
speed normal 3650 RPM
(unloaded), 2500 RPM (idle)
Control box internal wiring
malfunction
Circuit breaker will not turn on
"NO LOAD"
Defective circuit breaker?
Replace circuit breaker.
Overload?
Reduce load or replace breaker.
Check load circuit for short.
Check solenoid.
Circuit breaker will turn on
"LOADED" but trips immediately.
Load circuit is shorted?
Stuck solenoid?
Does not accelerate from low to
high "NO LOAD"
Does not accelerate from low to
high "LOAD ACTIVE
Control box interal wiring
defective?
Check control box wiring.
Defective rotor windings?
Defective solenoid?
Check or replace rotor.
Check or replace solenoid.
Does not decelerate no
"VOLTAGE OUTPUT".
Defective idle control device?
Defective solenoid?
Check or replace idle control device.
Check or replace idle control device.
Check control box wiring, replace any defective components.
Check or replace solenoid.
Control box wiring malfunction?
Defective solenoid?
Does not decelerate but has
"VOLTAGE OUTPUT".
Idle control device malfunction?
Check or replace idle control device.
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 31
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — EXPLANATION OF CODE IN REMARKS COLUMN
How to read the marks and remarks used in this parts
book.
The contents of this catalog are
subject to change without notice.
Items Found In the “Remarks” Column
Serial Numbers-Where indicated, this indicates a serial
number range (inclusive) where a particular part is used.
Model Number-Where indicated, this shows that the
corresponding part is utilized only with this specific model
number or model number variant.
Items Found In the “Items Number”Column
All parts with same symbol in the number column, , #,
<, belong to the same assembly or kit.
+, %, or
*
If more than one of the same
reference number is listed, the
last one listed indicates newest
(or latest) part available.
PAGE 32 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — SUGGESTED SPARE PARTS
MQ GA-2.9R GENERATOR 1 TO 3 UNITS WITH ROBIN
EX170D20210 ENGINE
1 to 3 Units
Qty.
P/N
Description
1 ............ A9924800014........ CAP, FUEL TANK
1 ............ A9924800004........ FUEL FILTER, FUEL TANK
3 ............ 0650140150 .......... SPARK PLUG
3 ............ 2772361407 .......... ELEMENT, AIR CLEANER
1 ............ 5825011118 .......... ROPE, RECOIL STARTER
Part numbers on this
Suggested Spare Parts
List may supercede/
replace the P/N shown in
the text pages of this
book.
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 33
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — NAME PLATE AND DECALS
NAMEPLATE AND DECALS.
PAGE 34 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — NAME PLATE AND DECALS
NAMEPLATE DECALS.
NO.
1
2
3
4
5
6
7
8
PART NO.
A2511201002
1630680104
PART NAME
QTY.
REMARKS
DECAL;CONTROL PANEL ....................................... 1............... A21120100
DECAL; FUEL COCK ................................................ 1............... S-1407
NAMEPLATE ............................................................ 1............... CONTACT MQ PARTS DEPT.
DECAL; GROUND ..................................................... 1............... S-1123
DECAL;WARNING DANGEROUS GAS ................... 1............... S-4984
DECAL; DANGER ELECTRICAL SHOCK HAZ. ....... 1............... S-4985
0800628504
8700611804
8700611904
A92120000
7900636004
0820610404
35137
DECAL;OPERATING INSTRUCTIONS
DECAL; CAUTION OPER. AT 3600 RPM ONLY ....... 1............... S-4461
DECAL;WARNING.................................................... 1............... S-3627
DECAL;CAUTION
DECAL; MQ MULTIQUIP 2900
1
9
10
11
1
1
A2561000103
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 35
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — GENERATOR ASSY.
GENERATOR ASSY.
PAGE 36 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — GENERATOR ASSY.
GENERATOR ASSY.
NO
1
PART NO
PART NAME
QTY.
REMARKS
7931000203
ROTOR ASSY. ............................... 1 ............. INCLUDES ITEMS W/
*
1-1
FIELD COIL ASSY. ......................... 1 ............. NOT SOLD SEPERATELY
RECTIFIER ..................................... 2 ............. D3SB 80
SURGE ABSORBER ...................... 2 ............. TNR 15G431K
BEARING ........................................ 1 ............. 6204 2RU NY5C S30
SET BOLT, ROTOR
SET WASHER, BEARING
SPRING WASHER
ARMATURE ASSY. ......................... 1 ............. S/N 5497956 AND BELOW
ARMATURE ASSY. ......................... 1 ............. S/N 5497957 AND ABOVE
END BRACKET (C SIDE)
END BRACKET (B SIDE)
GUIDE PANEL, AIR
COVER
SET BOLT, STATOR
SPRING WASHER
PLAIN WASHER
GROMMET
*
1-2
1-2
1-3
2
0601823213
0601822638
0603000040
7681017104
0801086004
0040008000
7921341803
A2135000203
7931315002
7931315102
7875021523
7681331003
7681344204
0040006000
0041206000
7871329514
0601851760
0013608025
0013608020
0040008000
*
1
1
1
3
4
5
5
6
7
8
9
10
11
12
13
14
15
15
1
1
1
1
4
4
4
1
1
CAP
HEX. HEAD BOLT ........................... 4 ............. S/N 5497956 AND BELOW
HEX. HEAD BOLT ........................... 4 ............. S/N 5497957 AND ABOVE
SPRING WASHER
15A
4
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 37
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — CONTROL BOX ASSY.
CONTROL BOX ASSY.
PAGE 38 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — CONTROL BOX ASSY.
CONTROL BOX ASSY.
NO
1
2
3
4
5
6
7
8
PART NO
PART NAME
CONTROL BOX
GROMMET
QTY.
1
1
REMARKS
A0101000103
0801354504
0601823204
0027103012
A2224000103
0601804889
3011816004
0021004010
0601806819
0601812598
0601812592
0021004010
0207004000
0021004015
0207004000
0017106016
0017105010
RECTIFIER ............................................... 1 ................. S5VB60
MACHINE SCREW
CONTROL PANEL
CIRCUIT BREAKER.................................. 1 ................. KM-51 : 22A
BRACKET, CIRCUIT BREAKER
MACHINE SCREW
AC VOLTMETER ...................................... 1 ................. DE450-011 : 0 ~ 120V
RECEPTACLE ........................................... 1 ................. 5-20R:125V, 20A
RECEPTACLE ........................................... 1 ................. L5-20R:125V, 20A
MACHINE SCREW
HEX NUT
MACHINE SCREW
HEX NUT
HEX. HEAD BOLT
HEX. HEAD BOLT
1
1
1
2
9
10
11
12
12A
13
13A
14
15
4
4
4
1
4
4
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 39
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — PIPE FRAME ASSY.
PIPE FRAME ASSY.
PAGE 40 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
MQ GA-2.9R — PIPE FRAME ASSY.
PIPE FRAME ASSY.
NO
1
2
3
4
5
5A
6
7
8
PART NO
PART NAME
QTY.
REMARKS
A2417000302
7935419204
7935416004
0207008000
0207008000
0801086004
A2365000102
A9924800014
A9924800004
0602125034
0605510028
0642007810
0642006410
0605513169
0605515061
7855525514
7855525604
0016908030
0016908020
A2331400004
0013606016
0040106000
0019206016
PIPE FRAME
1
2
2
6
2
1
1
1
1
1
RUBBER SUSPENSION
RUBBER SUSPENSION
HEX. NUT
HEX. NUT
WASHER
FUELTANK
CAP, FUEL TANK
FUEL FILTER
FUEL GAUGE, CJ- 58A
FUEL STRAINER ...................................... 1 ................. INCLUDES ITEMS W/
CUP, FILTER, FUEL STRAINER
PACKING, FUEL STRAINER
HOSE
HOSE BAND
RUBBER CUSHION
COLLAR
HEX. HEAD BOLT
HEX. HEAD BOLT
BRACKET
HEX. HEAD BOLT
SPRING WASHER
HEX. HEAD BOLT
9
10
10-1
10-2
11
12
13
14
15
16
17
18
18A
19
*
1
1
1
2
2
2
2
2
1
2
1
1
*
*
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 41
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — CRANKCASE ASSY.
CRANKCASE ASSY..
PAGE 42 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210— CRANKCASE ASSY.
CRANKCASE ASSY.
NO
10
20#
26#
PART NO
PART NAME
QTY.
REMARKS
2771010241
2371420103
2771601001
0440250200
0600280021
2771501103
0105080250
0105060351
0440060020
0401140030
0211140020
2771100131
CRANKCASE CP .......................1............... INCLUDES ITEM W/
*
VALVE GUIDE
STEM SEAL
OIL SEAL
BALL BEARING
PIPE KNOCK
STUD
STUD
OIL SEAL
PLUG
2
1
1
1
2
2
2
1
2
2
30
*
40
*
50
*
60#
70#
75
80
90
*
GASKET
210
MAIN BEARING COVER C ........1............... INCLUDES ITEM W/%
OIL SEAL
1
1
1
1
1
1
1
1
6
BALL BEARING, 6205
GOVERNOR GEAR CP
GOVERNOR SLEEVE
OIL GAUGE
FILLER PLUG
GASKET
GASKET
FLANGE BOLT
CYLINDER HEAD CP ................1............... INCLUDES ITEM W/#
GASKET, HEAD
FLANGE BOLT
1
4
1
1
1
2
4
1
1
FLANGE BOLT
ROCKER COVER CP
GASKET, ROCKER COVER
PIPE KNOCK
FLANGE BOLT
RUBBER PIPE
GASKET SET
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 43
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — CRANKSHAFT AND PISTON ASSY.
CRANKSHAFT AND PISTON ASSY.
PAGE 44 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — CRANKSHAFT AND PISTON ASSY.
CRANKSHAFT ASSY.
NO
10
50
PART NO
PART NAME
CRANKSHAFT CP
FLANGE NUT
QTY.
REMARKS
2772020121
0180140020
0323030010
2772250110
2772300103
2772330103
2772340103
2772340303
2772340403
2772351107
2772351217
2772351317
0565160010
1
1
1
70
WOODRUFF KEY
310
320
350
360
360
360
370
370
370
380
CONNECTING ROD ASSY. ...................................... 1 ......... INCLUDES ITEMS W/
CONNECTING ROD BOLT
PISTON PIN
*
2
1
1
1
1
1
1
1
2
*
PISTON
PISTON, OVERSIZE 0.25 MM
PISTON, OVERSIZE 0.50 MM
PISTON RING SET
PISTON RING SET, OVERSIZE 0.25 MM
PISTON RING SET, OVERSIZE 0.50 MM
CLIP
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 45
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — GOVERNOR ASSY.
GOVERNOR ASSY.
PAGE 46 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — GOVERNOR ASSY.
GOVERNOR ASSY.
NO
10
20
30
40
50
60
70
80
PART NO
PART NAME
QTY.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
REMARKS
2774230113
2774220133
2774270101
2774280113
0031305000
0130060240
0186060020
2794250223
2764250533
2774330301
2774350103
0200060170
0217060070
0043106250
2374500423
2774390203
0131050030
2774600201
0043104080
0023506000
674510103
0110060020
2774370101
2774600210
GOVERNOR LEVER
GOVERNOR SHAFT
GOVERNOR ROD CP
ROD SPRING
CLIP
BOLT & WASHER ASSY.
NUT
GOVERNOR SPRING
GOVERNOR SPRING
SPEED CONTROL LEVER
STOP PLATE
WASHER
FRICTION, WASHER
SCREW
SPRING, ADJUST
CLAMP
SCREW & WASHER ASSY.
SPEED CONT. BRKT CP ................ 1 ......... CAN ONLY BE PURCHASED W/ITEM 490
SCREW
80
310
340
350
355
360
365
395
396
435
440
450
480
485
486
490
*
*
*
*
*
*
*
*
*
*
*
*
1
1
1
1
2
1
SELF LOCK NUT
RETURN SPRING
FLANGE BOLT
LINK ROD
*
SPEED CONTROL ASSY. .............. 1 ......... INCLUDES ITEMS W/
*
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 47
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — INTAKE AND EXHAUST ASSY.
INTAKE AND EXHAUST ASSY.
PAGE 48 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — INTAKE AND EXHAUST ASSY.
INTAKE AND EXHAUST ASSY.
NO
10
PART NO
PART NAME
QTY.
REMARKS
2773160111
2773510103
0240060010
2773860103
2773640103
2773650103
2773870203
2793360103
2693370103
2773340113
2773350113
13210KA031
2773560111
CAM SHAFT CP ....................................... 1 ................. INCLUDES ITEMS W/%
25
PIN, CAM SHAFT
O-RING
1
1
1
1
1
1
2
2
1
1
4
1
27
34%
35%
37%
38%
60
PIN, SPRING
RELEASE LEVER
CLIP
RETURN SPRING
VALVE SPRING
SPRING RETAINER
INTAKE VALVE
EXHAUST VALVE
COLLET VALVE
TIMING CHAIN CP
70
80
90
95
150
160
163
166
170
200
210
220
225
230+
240+
290
310
2773691103
2773710103
2773690203
2773691313
2773500203
0031305000
2773620100
2773620200
0149050020
0170050020
0110060020
2773011101
2773760101
0150040060
2773240111
2773520113
9802008280
0152060090
0110060010
0110080150
2773700103
0150040060
2773290113
2773590113
TENTIONER
1
1
1
1
1
1
SPRING, TENTIONER
PIN, TENTIONER
CHAIN GUIDE
PIN, ROCKER
CLIP
ROCKER ARM, IN, ASSY......................... 1 ................. INCLUDES ITEM W/+
ROCKER ARM, EX, ASSY. ...................... 1 ................. INCLUDES ITEM W/+
ADJUST SCREW
NUT
FLANGE BOLT
1
1
1
MUFFLER/SPARK ARRESTOR ................ 1 ................. INCLUDES ITEMS W/
*
315
SPARK ARRESTOR
TAPPING SCREW
MUFFLER COVER CP
GASKET, MUFFLER
FLANGE NUT
TAPPING BOLT
FLANGE BOLT
FLANGE BOLT
DEFLECTOR
TAPPING SCREW
INSULATOR
GASKET, INSULATOR
1
1
1
1
2
2
1
1
1
2
1
1
*
317
*
320
340
350
360
361
365
440
445
540
550
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 49
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — AIR CLEANER ASSY.
AIR CLEANER ASSY.
PAGE 50 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — AIR CLEANER ASSY.
AIR CLEANER ASSY.
NO.
PART NO.
PART NAME
AIR CLEANER ASSY. (LOW PROFILE)
BACK PLATE
GASKET
COVER
QTY.
REMARKS
INCLUDES ITEMS W/
510
2773262010
2773261318
2773260408
2773261228
2773261407
1
1
1
1
1
*
510-200
510-220
510-250
*
*
*
520
ELEMENT ASSY., LOW PROFILE
*
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 51
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — COOLING STARTING ASSY.
COOLING STARTING ASSY.
PAGE 52 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — COOLING STARTING ASSY.
COOLING STARTING ASSY.
NO
PART NO
PART NAME
QTY.
REMARKS
10
2775120201
0732005140
0110060030
2775271111
2775270203
0010406160
0110060020
2695020130
2705011508
2695012008
5825011118
2615010008
2705012508
2275013108
2695014518
2705026108
2275015208
0110060010
BLOWER HOUSING CP
LABEL, TRADEMARK
FLANGE BOLT
1
1
4
1
1
1
1
20
40
60
61
80
81
210
210-1
210-2
210-3
210-4
210-5
210-6
210-11
210-35
210-49
220
BAFFLE 1, CASE CP
BAFFLE 2, HEAD
FLANGE BOLT
FLANGE BOLT
RECOIL STARTER ASSY. ................................... 1 ......... INCLUDES ITEM W/
SPIRAL SPRING
REEL
STARTER ROPE
STARTER KNOB
RATCHET
FRICTION SPRING
STARTER PULLEY
RATCHET GUIDE
SET SCREW
*
1
1
1
1
2
1
1
1
1
4
*
*
*
*
*
*
*
*
*
FLANGE BOLT
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 53
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 —CARBURETOR ASSY.
CARBURETOR ASSY.
PAGE 54 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — CARBURETOR ASSY.
CARBURETOR ASSY.
NO
PART NO
PART NAME
QTY.
REMARKS
210
2776230420
2776253508
2096235108
2776252708
2376245108
2466242008
2776257008
2776257108
2776256008
2776253108
2276245108
2776250008
2776251508
2776250608
2146245008
2146254008
2266250608
2776244008
2266241108
2776241208
2266270118
2776236008
2466239008
2486241008
1066241008
2366268008
2366254108
CARBURETOR ASSY. ............................ 1 ......... INCLUDES ITEM W/
*
210-1
210-2
210-3
210-4
210-5
210-6
210-7
210-8
210-11
210-12
210-14
210-15
210-16
210-17
210-18
210-19
210-20
210-22
210-22
210-24
210-28
210-32
210-44
210-45
210-62
THROTTLE VALVE
THROTTLE SCREW
CHOKE VALVE
SCREW, CHOKE, LOW PROFILE
PILOT JET, #40
RING, UPPER, LOW PROFILE
RING, LOWER, LOW PROFILE
CHOKE LEVER
THROTTLE SHAFT
BOLT
NEEDLE
PIN
FLOAT BODY
PACKING
CHAMBER PACKING
FLOAT ASSY.
MAIN NOZZLE
MAIN JET, #77.5
MAIN JET, #76.3
CLIP
BOLT
SEAL
AIR JET
AIR JET, PILOT
SEAL
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
210-104
PACKING
*
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 55
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — FLYWHEEL ASSY.
FLYWHEEL ASSY.
PAGE 56 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — FLYWHEEL ASSY.
FLYWHEEL ASSY.
NO
10
11
30
50
60
70
80
100
110
PART NO
PART NAME
QTY.
REMARKS
2777923011
2777943101
0011406250
27773101H1
X660000361
0150040090
0241070110
0650140150
0655000270
FLYWHEEL CP
IGNITION COIL CP
BOLT & WASHER
WIRE 1 CP
1
1
2
1
1
2
1
SWITCH ASSY.
TAPPING SCREW
GROMMET
SPARK PLUG.......................................... 1.................... NGK BR6HS
SPARK PLUG CAP
1
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 57
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — ELECTRIC DEVICE ASSY.
ELECTRIC DEVICE ASSY.
PAGE 58 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
ROBIN EX170D20210 — ELECTRIC DEVICE ASSY.
ELECTRIC DEVICE ASSY.
NO
700
705
740
741
770
775
PART NO
PART NAME
QTY.
REMARKS
2777630111
KU31104311
0011406160
0150040090
2147900601
0110060020
OIL SENSOR CP
FLOAT, C/U CP3
BOLT & WASHER ASSY.
TAPPING SCREW
CLAMP CP
1
1
2
1
1
1
FLANGE BOLT
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 59
Download from Www.Somanuals.com. All Manuals Search And Download.
Effective: October 1, 2003
TERMS AND CONDITIONS OF SALE — PARTS
PAYMENT TERMS
5. Partsmustbeinnewandresalablecon-
dition,intheoriginalMultiquippackage(if
any), and with Multiquip part numbers
clearlymarked.
Multiquipreservestherighttoquoteandsell
directtoGovernmentagencies,andtoOrigi-
nalEquipmentManufactureraccountswho
useourproductsasintegralpartsoftheirown
products.
Terms of payment for parts are net 10 days.
FREIGHTPOLICY
All parts orders will be shipped collect or
prepaidwiththechargesaddedtotheinvoice.
All shipments are F.O.B. point of origin.
Multiquip’sresponsibilityceaseswhenasigned
manifesthasbeenobtainedfromthecarrier,
andanyclaimforshortageordamagemustbe
settledbetweentheconsigneeandthecarrier.
6. Thefollowingitemsarenotreturnable:
SPECIALEXPEDITINGSERVICE
a. Obsolete parts. (If an item is in the
price book and shows as being re-
placedbyanotheritem,itisobsolete.)
A $35.00 surcharge will be added to the in-
voice for special handling including bus
shipments, insured parcel post or in cases
whereMultiquipmustpersonallydeliverthe
partstothecarrier.
b. Any parts with a limited shelf life
(such as gaskets, seals, “O” rings,
andotherrubberparts)thatwerepur-
chasedmorethansixmonthspriorto
thereturndate.
MINIMUMORDER
LIMITATIONSOFSELLER’SLIABILITY
The minimum charge for orders from Mul-
tiquipis$15.00net.Customerswillbeasked
for instructions regarding handling of orders
notmeetingthisrequirement.
Multiquip shall not be liable hereunder for
damagesinexcessofthepurchasepriceof
the item with respect to which damages are
claimed, and in no event shall Multiquip be
liable for loss of profit or good will or for any
otherspecial,consequentialorincidentaldam-
ages.
c. Anylineitemwithanextendeddealer
netpriceoflessthan$5.00.
d. Special order items.
RETURNEDGOODSPOLICY
e. Electricalcomponents.
f. Paint,chemicals,andlubricants.
g. Decalsandpaperproducts.
h. Itemspurchasedinkits.
Returnshipmentswillbeacceptedandcredit
willbeallowed,subjecttothefollowingprovi-
sions:
LIMITATIONOFWARRANTIES
1. AReturnedMaterialAuthorizationmust
be approved by Multiquip prior to ship-
ment.
Nowarranties,expressorimplied,aremade
in connection with the sale of parts or trade
accessoriesnorastoanyenginenotmanu-
facturedbyMultiquip.Suchwarrantiesmade
inconnectionwiththesaleofnew,complete
unitsaremadeexclusivelybyastatementof
warranty packaged with such units, and
Multiquipneitherassumesnorauthorizesany
persontoassumeforitanyotherobligationor
liabilitywhateverinconnectionwiththesale
ofitsproducts.Apartfromsuchwrittenstate-
ment of warranty, there are no warranties,
express, implied or statutory, which extend
beyondthedescriptionoftheproductsonthe
facehereof.
7. Thesenderwillbenotifiedofanymaterial
receivedthatisnotacceptable.
2. ToobtainaReturnMaterialAuthorization,
alistmustbeprovidedtoMultiquipParts
Salesthatdefinesitemnumbers,quanti-
ties, and descriptions of the items to be
returned.
8. Suchmaterialwillbeheldforfiveworking
days from notification, pending instruc-
tions.Ifareplyisnotreceivedwithinfive
days,thematerialwillbereturnedtothe
senderathisexpense.
a. Thepartsnumbersanddescriptions
must match the current parts price
list.
9. Creditonreturnedpartswillbeissuedat
dealer net price at time of the original
purchase,lessa15%restockingcharge.
b. The list must be typed or computer
generated.
10. In cases where an item is accepted, for
which the original purchase document
can not be determined, the price will be
basedonthelistpricethatwaseffective
twelvemonthspriortotheRMAdate.
c. The list must state the reason(s) for
thereturn.
d. The list must reference the sales
order(s)orinvoice(s)underwhichthe
itemswereoriginallypurchased.
11. Credit issued will be applied to future
purchasesonly.
e. The list must include the name and
phonenumberofthepersonrequest-
ingtheRMA.
PRICINGANDREBATES
Prices are subject to change without prior
notice.Pricechangesareeffectiveonaspe-
cificdateandallordersreceivedonorafterthat
datewillbebilledattherevisedprice.Rebates
3. AcopyoftheReturnMaterialAuthoriza-
tionmustaccompanythereturnshipment.
4. Freight is at the sender’s expense. All forpricedeclinesandaddedchargesforprice
partsmustbereturnedfreightprepaidto increaseswillnotbemadeforstockonhand
Multiquip’sdesignatedreceivingpoint.
atthetimeofanypricechange.
PAGE 60 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE PAGE
MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 61
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION AND PARTS MANUAL
HERE'S HOW TO GET HELP
PLEASE HAVETHE MODEL AND SERIAL
NUMBER ON-HANDWHEN CALLING
MULTIQUIP CORPORATE OFFICE
18910 Wilmington Ave.
Carson, CA 90746
800-421-1244
FAX:310-537-3927
Email: [email protected]
Internet:www.multiquip.com
PARTS DEPARTMENT
800-427-1244
310-537-3700
FAX:800-672-7877
FAX:310-637-3284
MAYCO PARTS
800-306-2926
310-537-3700
FAX:800-672-7877
FAX:310-637-3284
SERVICE DEPARTMENT
800-421-1244
FAX:310-537-4259
310-537-3700
TECHNICAL ASSISTANCE
800-478-1244
FAX:310-631-5032
FAX:310-537-1173
WARRANTYDEPARTMENT
800-421-1244,EXT.279
310-537-3700,EXT.279
Manufactured for MULTIQUIP INC.
by
DENYO MANUFACTURING CO., JAPAN
Your Local Dealer is:
MULTIQUIP INC.
18910 WILMINGTONAVE.
CARSON, CALIFORNIA 90746
800-421-1244 • 310-537-3700
FAX:310-537-3927
E-mail:[email protected]
Internet:multiquip.com
Download from Www.Somanuals.com. All Manuals Search And Download.
|