ELECTRIC DRYER INSTALLATION INSTRUCTIONS  
U.S.A. ONLY  
TABLE OF CONTENTS  
TABLE OF CONTENTS ..................................................................1  
DRYER SAFETY..............................................................................1  
INSTALLATION REQUIREMENTS................................................2  
Tools and Parts ............................................................................2  
Optional Equipment .....................................................................2  
Location Requirements................................................................3  
ELECTRIC DRYER POWER HOOKUP .........................................4  
Electrical Requirements ...............................................................4  
Electrical Connection ...................................................................5  
VENTING........................................................................................10  
Venting Requirements................................................................10  
Plan Vent System.......................................................................11  
Install Vent System.....................................................................12  
INSTALL LEVELING LEGS...........................................................12  
CONNECT VENT...........................................................................12  
CONNECT INLET HOSE (STEAM MODELS)..............................13  
LEVEL DRYER ..............................................................................13  
COMPLETE INSTALLATION .......................................................13  
Reverse Door Swing...................................................................14  
TROUBLESHOOTING .................................................................15  
Dryer Operation..........................................................................15  
Dryer Results..............................................................................16  
DRYER SAFETY  
Your safety and the safety of others are very important.  
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety  
messages.  
This is the safety alert symbol.  
This symbol alerts you to potential hazards that can kill or hurt you and others.  
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”  
These words mean:  
You can be killed or seriously injured if you don't immediately  
follow instructions.  
DANGER  
You can be killed or seriously injured if you don't  
instructions.  
follow  
WARNING  
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can  
happen if the instructions are not followed.  
W10267633A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dryer Dimensions  
Location Requirements  
431/2"  
(1105 mm)  
221/4"  
(565 mm)  
291/4"  
(743 mm)  
29"  
(737 mm)  
NOTE: Most installations require minimum 5" (127 mm) clearance  
for exhaust vent with elbow. See “Venting Requirements.”  
Installation spacing for recessed area or closet installation  
You will need  
The following spacing dimensions are recommended for this dryer.  
Dryer has been tested for spacing of 0" (0 mm) clearance on sides  
and rear. Consider recommended spacing for following reasons:  
A location that allows proper exhaust installation. See “Venting  
Requirements.”  
A separate 30-amp circuit.  
Consider additional spacing for ease of installation and service.  
May need additional clearance for wall, door, and floor moldings.  
If using a power supply cord, a grounded electrical outlet  
within 2 ft (610 mm) of either side of dryer. See “Electrical  
Requirements.”  
Consider additional spacing on all sides of dryer to reduce noise  
transfer.  
A sturdy floor to support total dryer weight of 200 lbs. (90.7 kg).  
Also consider combined weight of a companion appliance.  
For closet installation, with a door, minimum ventilation openings  
in the top and bottom of the door are required. Equivalent  
ventilation openings in louvered doors are acceptable.  
A level floor with maximum slope of 1" (25 mm) under entire  
dryer. If slope is greater than 1" (25 mm), install Extended Dryer  
Feet Kit, Part Number 279810. Clothes may not tumble properly  
and automatic sensor cycles may not operate correctly if dryer is  
not level.  
Consider spacing for companion appliance.  
Additional space required for rear exhaust of dryer to right or left.  
For a garage installation, place dryer at least 18" (457 mm)  
above floor. If using a pedestal, you will need 18" (457 mm) to  
bottom of dryer.  
14" máx.*  
48" 2  
*
(356 mm)  
(310 cm2)  
3"*  
18"*  
Steam models only: Cold water faucets located within  
4 ft. (1.2 m) of dryer, and water pressure of 20-100 psi  
(137.9-689.6 kPa). Cold water supply may come from  
washer using “Y” connector provided.  
(76 mm)  
(457 mm)  
3"*  
(76 mm)  
24" 2  
*
(155 cm2)  
Do not operate your dryer at temperatures below 45ºF (7ºC). At  
lower temperatures, the dryer may not shut off at the end of an  
automatic sensor cycle, possibly resulting in longer drying times.  
1"  
(25 mm)  
1"  
(25 mm)  
5"  
29"  
(737 mm)  
291/4"  
(743 mm)  
(127 mm)  
Do not install or store dryer where it will be exposed to water and/or  
weather.  
Recessed  
area  
Side view- closet  
or confined area  
Closet door with  
vents  
Check code requirements. Some codes limit, or do not permit,  
installation of dryer in garages, closets, mobile homes, or sleeping  
quarters. Contact your local building inspector.  
*Required spacing  
Mobile home - Additional installation requirements  
Dryer is suitable for mobile home installations. Installation must  
conform to Manufactured Home Construction and Safety Standard,  
Title 24 CFR, Part 3280 (formerly Federal Standard for Mobile Home  
Construction and Safety, Title 24, HUD Part 280) or Standard CAN/  
CSA-Z240 MH.  
Installation clearances  
Location must be large enough to allow dryer door to open fully.  
Mobile home installations require:  
Metal exhaust system hardware, available for purchase from  
your dealer.  
Special provisions must be made in mobile homes to introduce  
outside air into dryer. Openings (such as a nearby window)  
should be at least twice as large as dryer exhaust opening.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRIC DRYER POWER HOOKUP  
Electrical Requirements  
If your outlet looks like this:  
It is your responsibility  
To contact a qualified electrical installer.  
Then choose a 4-wire power supply cord  
with ring or spade terminals and UL listed strain  
relief. The 4-wire power supply cord, at least 4 ft.  
(1.22 m) long, must have four 10-gauge copper  
wires and match a 4-wire receptacle of NEMA  
Type 14-30R. The ground wire (ground  
conductor) may be either green or bare.  
The neutral conductor must be identified  
by a white cover.  
To be sure that the electrical connection is adequate and  
in conformance with the National Electrical Code, ANSI/NFPA  
70-latest edition and all local codes and ordinances.  
The National Electrical Code requires a 4-wire power supply  
connection for homes built after 1996, dryer circuits involved in  
remodeling after 1996, and all mobile home installations.  
4-wire receptacle  
(14-30R)  
A copy of the above code standards can be obtained from:  
National Fire Protection Association, One Batterymarch Park,  
Quincy, MA 02269.  
If your outlet looks like this:  
Then choose a 3-wire power supply cord with  
ring or spade terminals and UL listed strain relief.  
The 3-wire power supply cord, at least 4 ft  
(1.22 m) long, must have three 10-gauge copper  
wires and match a 3-wire receptacle of NEMA  
Type 10-30R.  
To supply the required 3 or 4 wire, single phase, 120/240 volt,  
60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt  
electrical supply, if specified on the serial/rating plate) on  
a separate 30-amp circuit, fused on both sides of the line.  
A time-delay fuse or circuit breaker is recommended. Connect  
to an individual branch circuit. Do not have a fuse in the neutral  
or grounding circuit.  
3-wire receptacle  
(10-30R)  
Do not use an extension cord.  
If connecting by direct wire:  
Power supply cable must match power supply (4-wire or 3-wire)  
and be:  
If codes permit and a separate ground wire is used, it is  
recommended that a qualified electrician determine that  
the ground path is adequate.  
Flexible armored cable or nonmetallic sheathed copper cable  
(with ground wire), protected with flexible metallic conduit. All  
current-carrying wires must be insulated.  
Electrical Connection  
To properly install your dryer, you must determine the type of  
electrical connection you will be using and follow the instructions  
provided for it here.  
10-gauge solid copper wire (do not use aluminum) at least  
5 ft. (1.52 m) long.  
This dryer is manufactured ready to install with a 3-wire  
electrical supply connection. The neutral ground conductor  
is permanently connected to the neutral conductor (white wire)  
within the dryer. If the dryer is installed with a 4-wire electrical  
supply connection, the neutral ground conductor must be  
removed from the external ground connector (green screw),  
and secured under the neutral terminal (center or white wire)  
of the terminal block. When the neutral ground conductor  
is secured under the neutral terminal (center or white wire)  
of the terminal block, the dryer cabinet is isolated from  
the neutral conductor.  
If local codes do not permit the connection of a neutral ground  
wire to the neutral wire, see “Optional 3-wire connection”  
section.  
A 4-wire power supply connection must be used when  
the appliance is installed in a location where grounding through  
the neutral conductor is prohibited. Grounding through  
the neutral is prohibited for (1) new branch-circuit installations,  
(2) mobile homes, (3) recreational vehicles, and (4) areas where  
local codes prohibit grounding through the neutral conductors.  
If using a power supply cord:  
Use a UL listed power supply cord kit marked for use with clothes  
dryers. The kit should contain:  
A UL listed 30-amp power supply cord, rated 120/240 volt  
minimum. The cord should be type SRD or SRDT and be at least  
4 ft. (1.22 m) long. The wires that connect to the dryer must end  
in ring terminals or spade terminals with upturned ends.  
A UL listed strain relief.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Style 1: Power supply cord strain relief  
Electrical Connection  
Remove screws from a 3/4" (19 mm) UL listed strain relief  
(UL marking on strain relief). Put tabs of the two clamp  
sections into hole below terminal block opening so that  
one tab is pointing up and the other is pointing down, and  
hold in place. Tighten strain relief screws enough to hold two  
clamp sections together.  
WARNING  
A
B
Fire Hazard  
C
D
Use a new UL listed 30 amp power supply cord.  
Use a UL listed strain relief.  
Disconnect power before making electrical connections.  
A. Strain relief tab pointing up  
B. Hole below terminal block  
opening  
C. Clamp section  
D. Strain relief tab pointing down  
Connect neutral wire (white or center wire) to center  
terminal (silver).  
Ground wire (green or bare wire) must be connected to  
green ground connector.  
Put power supply cord through strain relief. Be sure that wire  
insulation on power supply cord is inside strain relief. Strain  
relief should have a tight fit with the dryer cabinet and be in  
a horizontal position. Do not further tighten strain relief  
screws at this point.  
Connect remaining 2 supply wires to remaining  
2 terminals (gold).  
Securely tighten all electrical connections.  
Failure to do so can result in death, fire, or  
electrical shock.  
1. Disconnect Power.  
2. Remove hold-down screw and terminal block cover.  
D
A B  
C
Style 2: Direct wire strain relief  
WARNING  
E
F
A. Terminal block cover  
B. Hold-down screw  
C. External ground conductor  
screw  
D. Center, silver-colored terminal  
block screw  
E. Neutral ground wire  
F. Hole below terminal block  
opening  
Fire Hazard  
Use 10 gauge solid copper wire.  
Use a UL listed strain relief.  
Disconnect power before making electrical connections.  
3. Install strain relief.  
Connect neutral wire (white or center wire) to center  
terminal (silver).  
Ground wire (green or bare wire) must be connected to  
green ground connector.  
Connect remaining 2 supply wires to remaining  
2 terminals (gold).  
Securely tighten all electrical connections.  
Failure to do so can result in death, fire, or  
electrical shock.  
Unscrew removable conduit connector and any screws from  
a 3/4" (19 mm) UL listed strain relief (UL marking on strain  
relief). Put threaded section of strain relief through hole  
below terminal block opening. Reaching inside terminal  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
block opening, screw removable conduit connector onto  
strain relief threads.  
If your home has:  
And you will be  
connecting to:  
Go to Section  
3-wire direct  
A fused  
3-wire connection:  
Direct Wire  
disconnect or  
circuit breaker  
box*  
(89 mm)  
*If local codes do not permit connection of a cabinet-ground  
conductor to the neutral wire, see “Optional 3-wire connection”  
section.  
A
B
4-wire connection: Power supply cord  
IMPORTANT: A 4-wire connection is required for mobile homes and  
where local codes do not permit use of 3-wire connections.  
C
F
B
A
A. Removable conduit connector  
B. Hole below terminal block opening  
C. Strain relief threads  
D
G
E
C
Put direct wire cable through strain relief. Strain relief should  
have a tight fit with dryer cabinet and be in a horizontal  
position. Tighten strain relief screw against direct wire cable.  
A. 4-wire receptacle (NEMA type 14-30R)  
B. 4-prong plug  
C. Ground prong  
D. Neutral prong  
E. Spade terminals with upturned ends  
F. 3/4" (19 mm) UL listed strain relief  
G. Ring terminals  
1. Remove center, silver-colored terminal block screw.  
2. Remove neutral ground wire from external ground conductor  
screw. Connect neutral ground wire and the neutral wire (white or  
center wire) of power supply cord under center, silver-colored  
terminal block screw. Tighten screw.  
B
4. Now complete installation following instructions for your type  
C
of electrical connection:  
4-wire (recommended)  
3-wire (if 4-wire is not available)  
Electrical Connection Options  
D
A
E
If your home has:  
And you will be  
connecting to:  
Go to Section  
4-wire receptacle  
(NEMA Type 14-30R)  
A UL listed,  
120/240-volt  
minimum,  
4-wire connection:  
Power supply cord  
30-amp, dryer  
power supply  
cord*  
A. Neutral ground wire.  
B. Center, silver-colored terminal block screw  
C. External ground conductor screw - Dotted line shows position  
of NEUTRAL ground wire before being moved to center silver-  
colored terminal block screw  
4-wire direct  
A fused  
4-wire connection:  
Direct Wire  
disconnect or  
circuit breaker  
box*  
5"  
(127 mm)  
D. Neutral wire (white or center wire)  
E. 3/4" (19 mm) UL listed strain relief  
3-wire receptacle  
(NEMA type 10-30R)  
A UL listed,  
120/240-volt  
minimum,  
3-wire connection:  
Power supply cord  
30-amp, dryer  
power supply  
cord*  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Connect ground wire (green or bare) of power supply cord to  
When connecting to the terminal block, place the hooked end of the  
wire under the screw of the terminal block (hook facing right),  
squeeze hooked end together and tighten screw, as shown.  
external ground conductor screw. Tighten screw.  
1. Remove center, silver-colored terminal block screw.  
2. Remove neutral ground wire from external ground conductor  
screw. Connect neutral ground wire and place the hooked end  
(hook facing right) of the neutral wire (white or center wire) of direct  
wire cable under the center screw of the terminal block. Squeeze  
hooked ends together. Tighten screw.  
C
A. External ground conductor screw  
B. Neutral ground wire  
B
C. Ground wire (green or bare) of power supply cord  
D. 3/4" (19 mm) UL listed strain relief  
E. Center, silver-colored terminal block screw  
F. Neutral wire (white or center wire)  
D
A
4. Connect the other wires to outer terminal block screws. Tighten  
screws.  
E
A. Neutral ground wire.  
B. External ground conductor screw - Dotted line shows  
position of NEUTRAL ground wire before being moved to  
center, silver-colored terminal block screw  
C. Center, silver-colored terminal block screw  
D. Neutral wire (white or center wire)  
E. 3/4" (19 mm) UL listed strain relief  
5. Tighten strain relief screws.  
6. Insert tab of terminal block cover into slot of dryer rear panel.  
Secure cover with hold-down screw.  
7. You have completed your electrical connection. Now go to  
“Venting Requirements.”  
3. Connect ground wire (green or bare) of direct wire cable to  
external ground conductor screw. Tighten screw.  
4-wire connection: Direct wire  
IMPORTANT: A 4-wire connection is required for mobile homes and  
where local codes do not permit the use of 3-wire connections.  
E
A
Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer can  
be moved if needed.  
Strip 5" (127 mm) of outer covering from end of cable, leaving bare  
ground wire at 5" (127 mm). Cut 11/2" (38 mm) from 3 remaining  
wires. Strip insulation back 1" (25 mm). Shape ends of wires into a  
hook shape.  
B
C
F
D
A. External ground conductor screw  
B. Neutral ground wire  
C. Ground wire (green or bare) of power supply cable  
D. 3/4" (19 mm) UL listed strain relief  
E. Center, silver-colored terminal block screw  
F. Neutral wire (white or center wire)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Place the hooked ends of the other direct wire cable wires under  
the outer terminal block screws (hooks facing right). Squeeze  
hooked ends together. Tighten screws.  
3. Connect the other wires to outer terminal block screws. Tighten  
screws.  
4. Tighten strain relief screws.  
5. Insert tab of terminal block cover into slot of dryer rear panel.  
Secure cover with hold-down screw.  
5. Tighten strain relief screw.  
6. You have completed your electrical connection. Now go to  
6. Insert tab of terminal block cover into slot of dryer rear panel.  
“Venting Requirements.”  
Secure cover with hold-down screw.  
7. You have completed your electrical connection. Now go to  
3-wire connection: Direct wire  
“Venting Requirements.”  
Use where local codes permit connecting cabinet-ground  
conductor to neutral wire.  
3-wire connection: Power supply cord  
Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer can  
be moved if needed.  
Strip 31/2" (89 mm) of outer covering from end of cable. Strip  
insulation back 1" (25 mm). If using 3-wire cable with ground wire,  
cut bare wire even with outer covering. Shape ends of wires into a  
hook shape.  
Use where local codes permit connecting cabinet-ground  
conductor to neutral wire.  
E
B
D
A
C
F
G
A. 3-wire receptacle (NEMA type 10-30R)  
B. 3-wire plug  
C. Neutral prong  
D. Spade terminals with up turned ends  
E.3/4" (19 mm) UL listed strain relief  
F. Ring terminals  
When connecting to the terminal block, place the hooked  
end of the wire under the screw of the terminal block (hook facing  
right), squeeze hooked end together and tighten screw, as shown.  
G. Neutral (white or center wire)  
1. Loosen or remove center, silver-colored terminal block screw.  
2. Connect neutral wire (white or center wire) of power supply cord  
to the center, silver-colored terminal screw of the terminal block.  
Tighten screw.  
1. Loosen or remove center, silver-colored terminal block screw.  
A
C
B
D
E
A. External ground conductor screw  
B. Neutral ground wire  
C. Center, silver-colored terminal block screw  
D. Neutral wire (white or center wire)  
E. 3/4" (19 mm) UL listed strain relief  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Place the hooked end of the neutral wire (white or center wire) of  
direct wire cable under the center screw of terminal block (hook  
facing right). Squeeze hooked end together. Tighten screw.  
2. Remove neutral ground wire from external ground conductor  
screw. Connect neutral ground wire and the neutral wire (white or  
center wire) of power supply cord/cable under center, silver-  
colored terminal block screw. Tighten screw.  
C
A
C
A
B
D
E
B
D
E
F
D. Neutral wire (white or center wire)  
E. 3/4" (19 mm) UL listed strain relief  
A. External ground conductor  
screw  
D. Neutral wire  
(white or center wire)  
B. Neutral ground wire  
E. 3/4" (19 mm) UL listed  
3. Place the hooked ends of the other direct wire cable wires under  
the outer terminal block screws (hooks facing right). Squeeze  
hooked ends together. Tighten screws.  
strain relief  
C. Center, silver-colored terminal  
block screw  
F. Grounding path determined  
by a qualified electrician  
3. Connect the other wires to outer terminal block screws. Tighten  
screws.  
4. Tighten strain relief screw.  
5. Insert tab of terminal block cover into slot of dryer rear panel.  
Secure cover with hold-down screw.  
4. Tighten strain relief screws.  
6. You have completed your electrical connection. Now go to  
5. Insert tab of terminal block cover into slot of dryer rear panel.  
“Venting Requirements.”  
Secure cover with hold-down screw.  
6. Connect a separate copper ground wire from the external ground  
Optional 3-wire connection  
conductor screw to an adequate ground.  
Use for direct wire or power supply cord where local codes do  
not permit connecting cabinet-ground conductor to neutral wire.  
1. Remove center, silver-colored terminal block screw.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
VENTING  
Flexible metal vent  
Flexible metal vents are acceptable only if accessible  
for cleaning.  
Venting Requirements  
Flexible metal vent must be fully extended and supported when  
the dryer is in its final location.  
WARNING  
Remove excess flexible metal vent to avoid sagging and kinking  
that may result in reduced airflow and poor performance.  
Do not install flexible metal vent in enclosed walls, ceilings,  
or floors.  
The total length of flexible metal vent should not exceed 7¾ ft.  
(2.4 m).  
Fire Hazard  
Use a heavy metal vent.  
Elbows  
Do not use a plastic vent.  
45° elbows provide better airflow than 90° elbows.  
Do not use a metal foil vent.  
Failure to follow these instructions can result in death  
or fire.  
WARNING: To reduce the risk of fire, this dryer MUST BE  
EXHAUSTED OUTDOORS.  
IMPORTANT: Observe all governing codes and ordinances.  
Good  
Better  
The dryer exhaust must not be connected into any gas vent,  
chimney, wall, ceiling, attic, crawlspace, or a concealed space  
of a building. Only rigid or flexible metal vent shall be used for  
exhausting.  
Clamps  
Use clamps to seal all joints.  
Exhaust vent must not be connected or secured with screws or  
other fastening devices that extend into the interior of the duct  
and catch lint. Do not use duct tape.  
If using an existing vent system  
Clean lint from the entire length of the system and make sure  
exhaust hood is not plugged with lint.  
Replace any plastic or metal foil vent with rigid or flexible heavy  
metal vent.  
Clamp  
Review vent system chart. Modify existing vent system if  
necessary to achieve the best drying performance.  
Exhaust  
If this is a new vent system  
B
C
Vent material  
4"  
(102 mm)  
Use a heavy metal vent. Do not use plastic or metal foil vent.  
A
4" (102 mm) heavy metal exhaust vent and clamps must be  
used.  
4"  
(102 mm)  
2½"  
(64 mm)  
4"  
(102 mm)  
4"  
102 mm  
Recommended:  
A. Louvered hood style  
B. Box hood style  
Acceptable:  
C. Angled hood style  
4" (102 mm) heavy metal exhaust vent  
An exhaust hood should cap the vent to keep rodents and  
insects from entering the home.  
Vent products can be purchased from your dealer or by calling  
Whirlpool Service. For more information, see the “Assistance or  
Service” section in your Use and Care Guide.  
Exhaust hood must be at least 12" (305 mm) from the ground or  
any object that may be in the path of the exhaust (such as  
flowers, rocks or bushes, snow line, etc.).  
Rigid metal vent  
For best drying performance, rigid metal vents are  
recommended.  
Do not use an exhaust hood with a magnetic latch.  
Rigid metal vent is recommended to avoid crushing and kinking.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Improper venting can cause moisture and lint to collect  
indoors, which may result in:  
Moisture damage to woodwork, furniture, paint, wallpaper,  
carpets, etc.  
Housecleaning problems and health problems.  
A
B
C
A. Standard rear offset exhaust installation  
B. Left or right side exhaust installation  
C. Bottom exhaust installation  
Plan Vent System  
Choose your exhaust installation type  
Alternate installations for close clearances  
Recommended exhaust installations  
Venting systems come in many varieties. Select the type best for  
your installation. Two close-clearance installations are shown. Refer  
to the manufacturer’s instructions.  
Typical installations vent the dryer from the rear of the dryer.  
B
C
D
E
A
F
G
B
H
A. Over-the-top installation (also available with one offset elbow)  
B. Periscope installation  
A. Dryer  
B. Elbow  
C. Wall  
E. Clamps  
NOTE: The following kits for close clearance alternate installations  
are available for purchase. Please see the “Assistance or Service”  
section in your Use and Care Guide to order.  
F. Rigid metal or flexible metal vent  
G. Vent length necessary to connect elbows  
H. Exhaust outlet  
D. Exhaust hood  
Over-the-Top Installation:  
Part Number 4396028  
Optional exhaust installations  
Periscope Installation (For use with dryer vent to wall vent  
mismatch):  
Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch  
Part Number 4396011 - 18" (457 mm) to 29" (737 mm)  
mismatch  
Part Number 4396014 - 29" (737 mm) to 50" (1.27 m) mismatch  
Special provisions for mobile home installations  
The exhaust vent must be securely fastened to a noncombustible  
portion of the mobile home structure and must not terminate  
beneath the mobile home. Terminate the exhaust vent outside.  
Exhaust Cover Kit (to cover unused exhaust holes):  
Part Number W10186596 - all models  
This dryer can be converted to exhaust out the right side, left side or  
through the bottom. If you prefer, you may contact your local dealer  
to have the dryer converted.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Determine vent path  
INSTALL LEVELING LEGS  
Select the route that will provide the straightest and most direct  
path outdoors.  
WARNING  
Plan the installation to use the fewest number of elbows and  
turns.  
Excessive Weight Hazard  
When using elbows or making turns, allow as much room as  
possible.  
Use two or more people to move and install dryer.  
Failure to do so can result in back or other injury.  
Bend vent gradually to avoid kinking.  
Use the fewest 90° turns possible.  
1. To avoid damaging the floor, use a large flat piece of cardboard  
from the dryer carton. Place cardboard under the entire back  
edge of the dryer.  
Determine vent length and elbows needed for best  
drying performance  
2. Firmly grasp the body of the dryer (not the console panel). Gently  
Use the following vent system chart to determine type of vent  
material and hood combinations acceptable to use.  
lay the dryer on the cardboard. See illustration.  
NOTE: Do not use vent runs longer than those specified in the  
Vent system chart.  
Exhaust systems longer than those specified will:  
Shorten the life of the dryer.  
Reduce performance, resulting in longer drying times and  
increased energy usage.  
3. Examine the leveling legs. Find the diamond marking.  
The vent system chart provides venting requirements that will help  
to achieve the best drying performance.  
Vent system chart  
NOTE: Side and bottom exhaust installations have a 90º turn inside  
the dryer. To determine maximum exhaust length, add one 90º turn  
to the chart.  
4. Screw the legs into the leg holes by hand. Use a wrench to finish  
turning the legs until the diamond marking is no longer visible.  
Number 90º Type of vent  
Box /louvered  
hoods  
Angled  
hoods  
5. Place a carton corner post from dryer packaging under each of  
the 2 dryer back corners. Stand the dryer up. Slide the dryer on  
the corner posts until it is close to its final location. Leave enough  
room to connect the exhaust vent.  
elbows  
0
1
2
3
4
Rigid metal  
Rigid metal  
Rigid metal  
Rigid metal  
Rigid metal  
64 ft. (20 m)  
54 ft. (16.5 m)  
44 ft. (13.4 m)  
35 ft. (10.7 m)  
27 ft. (8.2 m)  
58ft. (17.7 m)  
48 ft. (14.6 m)  
38 ft. (11.6 m)  
29 ft. (8.8 m)  
21 ft. (6.4 m)  
CONNECT VENT  
1. Using a 4" (102 mm) clamp, connect vent to exhaust outlet in  
dryer. If connecting to existing vent, make sure the vent is clean.  
The dryer vent must fit over the dryer exhaust outlet and inside the  
exhaust hood. Check that the vent is secured to exhaust hood  
with a 4" (102 mm) clamp.  
Install Vent System  
2. Move dryer into its final location. Do not crush or kink vent.  
3. Once the exhaust vent connection is made, remove the corner  
1. Install exhaust hood. Use caulking compound to seal exterior wall  
posts and cardboard.  
opening around exhaust hood.  
2. Connect vent to exhaust hood. Vent must fit inside exhaust hood.  
Secure vent to exhaust hood with 4" (102 mm) clamp.  
CONNECT INLET HOSE  
(STEAM MODELS)  
3. Run vent to dryer location. Use the straightest path possible. See  
“Determine vent path” in “Plan Vent System.” Avoid 90º turns.  
Use clamps to seal all joints. Do not use duct tape, screws or  
other fastening devices that extend into the interior of the vent to  
secure vent, which can catch lint.  
The dryer must be connected to the cold water faucet using the new  
inlet hoses. Do not use old hoses.  
1. Turn cold water faucet off and remove washer inlet hose.  
2. Remove old rubber washer from inlet hose and replace with new  
rubber washer provided. If space permits, attach the brass female  
end of the “Y” connector to the cold water faucet.  
NOTE: If “Y” connector can be attached directly to cold water  
faucet, go to Step 6. If “Y” connector cannot be attached  
directly to the cold water faucet, the short hose must be used.  
Continue with Step 3.  
3. Attach short hose to cold water faucet. Screw on coupling by  
hand until it is seated on faucet.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Using pliers, tighten the couplings with an additional two-thirds  
turn.  
LEVEL DRYER  
Check the levelness of the dryer by first placing a level on the top  
of the dryer near the console.  
NOTE: Do not overtighten. Damage to the coupling can result.  
5. Attach “Y” connector to brass male end of small hose. Screw on  
coupling by hand until it is seated on connector.  
6. Attach straight end of long hose to “Y” connector.  
7. Attach washer cold inlet hose to other end of “Y” connector.  
Then, by placing a level in the crease on the side of the dryer  
between the top of the dryer and the dryer cabinet, check  
the levelness from front to back.  
Screw on coupling by hand until it is seated on connector.  
8. Using pliers, tighten the couplings an additional two-thirds turn.  
A
If the dryer is not level, prop up the dryer using a wood block. Use a  
wrench to adjust the legs up or down and check again for levelness.  
A. Inlet to cold water  
NOTE: Do not overtighten. Damage to the coupling can result.  
9. Attach angled end of long hose to fill valve at bottom of dryer  
back panel. Screw on coupling by hand until it is seated on fill  
valve connector.  
10. Using pliers, tighten the coupling an additional two-thirds turn.  
COMPLETE INSTALLATION  
1. Check that all parts are now installed. If there is an extra part,  
go back through the steps to see which step was skipped.  
2. Check that you have all of your tools.  
3. Dispose of/recycle all packaging materials.  
4. Check the dryer’s final location. Be sure the vent is not crushed  
or kinked.  
5. Check that the dryer is level. See “Level Dryer.”  
6. Remove the blue film on the console and any tape remaining on  
NOTE: Do not overtighten. Damage to the coupling can result.  
the dryer.  
7. Wipe the dryer drum interior thoroughly with a damp cloth to  
11. Check that the water faucets are on.  
12. Check for leaks around “Y” connector, faucet, and hoses.  
remove any dust.  
8. Read “Dryer Use” in your Use and Care Guide.  
9. For power supply cord installation, plug into a grounded outlet.  
For direct wire installation, turn on power.  
Steam Models Only:  
10. Be sure the water faucets are on.  
11. Check for leaks around “Y” connector, faucet, and hoses.  
12. If you live in a hard water area, use of a water softener is  
recommended to control the buildup of scale through the water  
system in the dryer. Over time, the buildup of lime scale may clog  
different parts of the water system, which will reduce product  
performance. Excessive scale buildup may lead to the need for  
certain part replacement or repair.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
All Models:  
5. Remove the 4 plastic plugs located outside the dryer door  
opening.  
13. Select a Timed Dry heated cycle, and start the dryer. Do not select  
the Air Only Temperature setting.  
If the dryer will not start, check the following:  
Controls are set in a running or “On” position.  
Start button has been pushed firmly.  
Dryer is plugged into an outlet and/or electrical supply  
is connected.  
Household fuse is intact and tight, or circuit breaker has  
not tripped.  
Dryer door is closed.  
This dryer automatically runs an installation diagnostic routine at the  
start of its first cycle.  
If you receive an L2 code, there may be a problem with your  
home power supply keeping the dryer’s heater from turning on.  
See “Troubleshooting.”  
If you receive an AF code, your dryer vent may be crushed or  
blocked. See “Troubleshooting.”  
6. Install 4 plastic plugs into screw holes in the dryer left where  
NOTE: You may notice an odor when the dryer is first heated.  
This odor is common when the heating element is first used.  
The odor will go away.  
the hinges were removed in Step 4.  
Reverse the strike  
1. Remove the door strike from the dryer door opening.  
2. Remove the cosmetic screw opposite the door strike.  
REVERSE DOOR SWING  
You can change your door swing from a right-side opening to a  
left-side opening, if desired.  
A
B
1. Place a towel or soft cloth on top of dryer or work space to  
avoid damaging the surface.  
Remove the door assembly  
1. Open the dryer door.  
2. Remove the bottom screw from each of the 2 hinges that  
attach dryer door to front panel of dryer.  
3. Loosen the top screw from each of the 2 hinges in Step 2.  
A. Door strike  
B. Cosmetic screw  
A
3. Reinstall the door strike and cosmetic screw on the opposite  
side of the dryer door opening from where they were  
removed.  
B
NOTE: Door strike and plugs must be on the same side of the  
dryer door opening.  
Reinstall the door  
1. Remove the 4 screws and 2 hinges from the dryer door.  
2. Replace the 4 screws in the same holes.  
A
B
A. Loosen these screws.  
B. Remove these screws.  
4. Remove the dryer door and the hinges by lifting upward on  
the door. Lay the door on a flat, protected surface, with the  
inside of the door facing up. Remove remaining 2 loose  
screws from dryer front panel.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Remove the 4 screws from the opposite side of the door.  
6. Hang door by placing screw heads into top slotted holes of  
hinges and slide door down. Align bottom screw holes in  
hinge and door. Install two bottom screws. Tighten all hinge  
screws.  
4. Install the 2 hinges to the front panel of the dryer using  
4 screws. Use the non-slotted side to attach the hinge to the  
front panel.  
7. Close door to engage door strike.  
5. Install screws in top hinge holes in the door. Do not tighten  
screws. Leave approximately 1/4" (5 mm) of screw exposed.  
TROUBLESHOOTING  
First try the solutions suggested here and possibly avoid the cost of a service call...  
No heat  
Dryer Operation  
Has a household fuse blown, or has a circuit breaker  
tripped?  
Dryer will not run  
The drum may be turning, but you may not have heat. Electric  
dryers use 2 household fuses or circuit breakers. Replace the  
fuse or reset the circuit breaker. If the problem continues, call an  
electrician.  
Has a household fuse blown, or has a circuit breaker  
tripped?  
There may be 2 household fuses or circuit breakers for the dryer.  
Check that both fuses are intact and tight, or that both circuit  
breakers have not tripped. Replace the fuse or reset the circuit  
breaker. If the problem continues, call an electrician.  
Dryer displaying code message  
Is the correct power supply available?  
Electric dryers require 240-volt power supply. Check with a  
qualified electrician.  
“PF” (power failure), check the following:  
Was the drying cycle interrupted by a power failure?  
Press and hold START to restart the dryer.  
Was a regular fuse used?  
Use a time-delay fuse.  
“L2” Diagnostic Code (low or no line voltage condition):  
The drum will turn, but there may be a problem with your home  
power supply keeping the dryer's heater from turning on. The  
dryer will continue to run when this diagnostic code is present.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Press any key to clear the code from the display and return to  
the estimated time remaining.  
outside exhaust hood to check air movement. If you do not feel  
air movement, clean exhaust system of lint or replace exhaust  
vent with heavy metal or flexible metal vent. See the Installation  
Instructions.  
Are fabric softener sheets blocking the grille?  
Use only one fabric softener sheet, and use it only once.  
Is the exhaust vent the correct length?  
Check that the exhaust vent is not too long or has too many  
turns. Long venting will increase drying times. See the  
Installation Instructions.  
Is the exhaust vent diameter the correct size?  
Use 4" (102 mm) diameter vent material.  
Try the following:  
Check to see if a household fuse has blown or circuit breaker  
has tripped. Electric dryers use two household fuses or  
breakers. Replace the fuse or reset the circuit breaker.  
Confirm the power cord is properly installed. Refer to “Electrical  
Connection” for details.  
Select a Timed Dry heated cycle, and restart the dryer.  
If the message persists, consult a qualified electrician.  
“AF” (low airflow condition):  
The dryer will continue to run when this diagnostic code is  
present. Press any key to clear the code from the display and  
return to the estimated time remaining.  
Try the following:  
Clean lint screen.  
Check to see if the vent run from the dryer to the wall is  
crushed or kinked.  
Confirm the vent run from the dryer to the wall is free of lint  
and debris.  
Confirm the exterior vent exhaust hood is free of lint and  
debris.  
Confirm your vent system falls within the recommended run  
length and number of elbows for the type of vent you are  
using. Refer to “Plan Vent System” for details.  
Select a Timed Dry heated cycle, and restart the dryer.  
If the message persists, have your entire home venting run  
cleaned.  
Is the dryer located in a room with temperature below 45ºF  
(7ºC)?  
Proper operation of dryer cycles requires temperatures above  
45ºF (7ºC).  
“E” Variable (E1, E2, E3) service codes:  
Call for service.  
Is the dryer located in a closet?  
Closet doors must have ventilation openings at the top and  
bottom of the door. The front of the dryer requires a minimum of  
1" (25 mm) of airspace, and, for most installations, the rear of the  
dryer requires 5" (127 mm). See the Installation Instructions.  
Dryer Results  
Clothes are not drying satisfactorily, drying times are too  
long, or load is too hot  
Is the lint screen clogged with lint?  
Lint screen should be cleaned before each load.  
WARNING  
Fire Hazard  
Use a heavy metal vent.  
Do not use a plastic vent.  
Do not use a metal foil vent.  
Failure to follow these instructions can result in death  
or fire.  
Is the exhaust vent or outside exhaust hood clogged with  
lint, restricting air movement?  
Run the dryer for 5-10 minutes. Hold your hand under the  
W10267633A  
© 2009 Whirlpool Corporation.  
All rights reserved.  
11/09  
Printed in U.S.A.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

LaCie Server 5big Backup Server User Manual
LG Electronics Cell Phone VX7000 User Manual
Life Fitness Elliptical Trainer 95LE 0XXX 01 User Manual
LOREX Technology Security Camera L15LD414161 User Manual
Mackie Stereo Amplifier 400F User Manual
Magic Chef Griddle MCSG19B User Manual
Magnavox Portable CD Player AZ 2407 User Manual
Makita Sander BO5021 User Manual
McIntosh Stereo Amplifier MC12KW User Manual
M Systems Flash Disk Pioneers Computer Accessories 91 SR 005 10 7L User Manual