Leica Laser Level 777067 R User Manual

Leica Lino  
L360, L2P5, L2+, L2G+, L2, P5, P3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
de  
en  
F
Charging / first-time use  
Storage of L360 NiMH Batteries  
Ensure that the product is stored in dry environ-  
ment with a temperature range of 0°C to +20°C /  
32°F to 68°F, in order to minimize the discharge  
rate of the battery.  
The battery must be charged prior to first use  
because it is delivered with as low an energy  
content as possible.  
The permissible temperature range for charging is  
between 0°C and +40°C/+32°F and +104°F. For  
optimal charging we recommend charging the  
batteries at a low ambient temperature of +10°C  
to +20°C/+50°F to +68°F if possible.  
It is normal for the battery to become warm  
during charging.  
I
E
Recharge batteries before longer storage  
periods.  
P
NL  
DK  
S
At the recommended storage temperature range,  
batteries can be stored up to 6 months, after  
which the batteries should be fully recharged.  
After longer storage intervals, please recharge  
batteries before use.  
N
FIN  
J
L360  
Lino L360  
CN  
ROK  
PL  
HR  
H
RUS  
CZ  
GR  
LT  
1
LV  
EST  
SLO  
SK  
m
7h  
1 Jack for battery charger  
Leica Lino 757665i en  
2
Start up  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TR  
de  
en  
F
Operation  
6
4
7
Keypad and control elements  
1 LASER key  
2 PULSE/POWER SAVE MODE key  
3 Lock switch  
Lino L360  
I
7
5
8
E
10  
Lino L2P5  
P
6
1
11  
2
9
NL  
DK  
S
Display  
5
1
9
2
8
4 Laser crossline  
5 Horizontal laser line  
6 Vertical laser line  
7 Locked  
8 Pulse/Power save mode ON  
9 Battery voltage too low  
AT Plumb and crossline intersection point  
AK Plumb point  
N
FIN  
J
7
5
6
1
7
5
6
1
CN  
ROK  
PL  
HR  
H
+
+
Lino L2  
Lino L2G  
8
AL Laser switched on  
2
9
9
60  
Lino L3  
RUS  
CZ  
GR  
LT  
Leica Lino L2  
7
8
9
6
5
4
Leica Lino P3  
9
12  
1
LV  
EST  
SLO  
SK  
m
2
1
3
Leica Lino 757665i en  
3
Operation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TR  
 
de  
en  
F
Switching on/off  
Lino L360, L2P5, L2+, L2G+, and L2:  
Lino P3 and Lino P5:  
ON: Briefly press the LASER key 1.  
ON: Move the Lock switch 3 to the right.  
OFF: Press and hold down the LASER key 1.  
OFF: Move the Lock switch 3 to the left.  
I
E
Laser functions  
P
Pressing the LASER key 1 activates the following laser functions:  
NL  
DK  
S
L360  
L360  
L2P5  
L2P5  
Action  
L2  
L2+  
L2G+  
P3  
P5  
not in Lock  
mode  
in Lock  
mode  
not in Lock  
mode  
in Lock  
mode  
N
FIN  
J
horizontal  
only  
horizontal  
only  
horizontal  
horizontal  
horizontal  
1x  
2x  
3x  
all 3 points all 5 points  
only plumb only plumb  
and vertical horizontal and vertical horizontal and vertical and vertical and vertical  
CN  
ROK  
PL  
HR  
H
only  
horizontal  
all lines and  
points  
only  
horizontal  
only  
horizontal  
only  
horizontal  
only vertical  
only vertical  
points  
points  
plumb point  
and right/left  
only vertical again as 1x  
all points  
again as 1x only vertical only vertical only vertical again as 1x  
RUS  
CZ  
GR  
LT  
only plumb  
point  
4x  
5x  
again as 1x  
-
-
-
-
-
again as 1x again as 1x again as 1x  
-
-
again as 1x  
-
again as 1x  
-
-
-
LV  
EST  
SLO  
SK  
m
Leica Lino 757665i en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Operation  
TR  
de  
en  
F
Self-levelling and Lock functions  
Pulse/Power save mode  
The instrument automatically levels itself within the  
specified grade range (Refer to "Technical data") .  
Press the Lock switch 3 in order to transport or tilt  
the instrument beyond the self-levelling range. When  
locked, the pendulum is fixed and the self-levelling  
function is deactivated.  
(only Lino L360, L2P5, L2+, and L2)  
The instrument is fitted with a Power save mode. If  
particularly good visibility of the laser line is not  
necessary and you wish to save energy, you can  
switch the Pulse mode on and off by pressing the  
PULSE/POWER SAVE MODE key 2.  
I
E
P
To be able to detect the laser lines over long  
distances (> 15 m) or in unfavourable lighting condi-  
tions, a laser detector can be used. The detector is  
able to locate the laser beam in Pulse mode, even  
over long distances.  
NL  
DK  
S
N
(Laser detector refer to accessories)  
FIN  
J
The L2G+ operates in a continuously pulsed  
mode to optimize battery life and visibility, and as a  
consequence the L2G+ has no pulse/Power save  
button.  
CN  
ROK  
PL  
HR  
H
RUS  
CZ  
GR  
LT  
LV  
EST  
SLO  
SK  
m
Leica Lino 757665i en  
5
Operation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TR  
de  
en  
F
Applications  
I
E
P
NL  
DK  
S
N
FIN  
J
CN  
ROK  
PL  
HR  
H
RUS  
CZ  
GR  
LT  
LV  
EST  
SLO  
SK  
m
Leica Lino 757665i en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
Operation  
TR  
How to use the wall mount bracket:  
de  
en  
F
0
36  
no  
L
Li  
I
E
P
NL  
DK  
S
N
FIN  
J
CN  
ROK  
PL  
HR  
H
RUS  
CZ  
GR  
LT  
LV  
EST  
SLO  
SK  
m
Leica Lino 757665i en  
7
Operation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TR  
de  
en  
F
Checking the accuracy of the Leica  
Lino  
Check the accuracy of your Leica Lino regu-  
I
larly and particularly before important measuring  
E
tasks.  
A1  
A2  
P
B1  
B2  
Checking the accuracy of the levelling  
NL  
DK  
S
5 m  
Then place the instrument at the same elevation as  
close as possible to wall A and again mark the hori-  
zontal laser line or the laser point on wall A (-> A2) .  
Rotate the instrument by 180° again and mark the  
laser on wall B (-> B2). Measure the distances of the  
marked points A1-A2 and B1-B2. Calculate the differ-  
ence of the two measurements. If the difference  
does not exceed 2 mm, then the Leica Lino is within  
tolerance.  
N
FIN  
J
B1  
A1  
CN  
ROK  
PL  
HR  
H
2.5 m  
2.5 m  
Set the instrument on a tripod half-way between two  
walls (A+B) that are approx. 5 m apart.  
| (A1 - A2) - (B1 - B2) | 2 mm  
Place the Lock switch 3 in the "Unlocked" (  
)
RUS  
CZ  
GR  
LT  
position.  
Direct the instrument at wall A and switch on the  
instrument. Activate the horizontal laser line or laser  
point and mark the position of the line or the point  
on wall A (-> A1).  
Rotate the instrument by 180° and mark the hori-  
zontal laser line or the laser point in exactly the same  
way on wall B (-> B1).  
LV  
EST  
SLO  
SK  
m
Leica Lino 757665i en  
8
Operation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TR  
Checking the accuracy of the horizontal line Checking the accuracy of the vertical line:  
de  
en  
F
(only Lino L360, L2P5, L2+, L2G+, and L2)  
(only Lino L360, L2P5, L2+, L2G+, and L2)  
I
E
max.  
3 mm  
P
max.  
3 mm  
NL  
DK  
S
5 m  
1.5 m  
N
FIN  
J
Place the Lock switch 3 in the "Unlocked" (  
)
Place the Lock switch 3 in the "Unlocked" (  
)
position.  
position.  
CN  
ROK  
PL  
HR  
H
Position the instrument approx. 5 m away from the  
wall. Direct the instrument at the wall and switch on  
with the LASER key 1. Activate the laser line with the  
LASER key 1 and mark the intersection point of laser  
crosshairs on the wall.  
Swivel the instrument to the right and then to the  
left. Observe the vertical deviation of the horizontal  
line from the marking. If the difference does not  
As reference, use a plumb-bob and attach it as close  
as possible to an approx. 3 m high wall.  
Position the instrument at a distance of approx.  
1.5 m from the wall at an elevation of approx. 1.5 m.  
Direct the instrument at the wall and switch on with  
the LASER key 1. Activate the laser line with the  
LASER key 1. Rotate the instrument and align it with  
the bottom of the plumb line. Now read off the  
RUS  
CZ  
GR  
LT  
exceed 3 mm, then the Leica Lino is within tolerance. maximum deviation of the laser line from the top of  
the plumb line. If the difference does not exceed  
3 mm, then the Leica Lino is within tolerance.  
LV  
EST  
SLO  
SK  
m
Leica Lino 757665i en  
9
Operation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TR  
Rotate the instrument by 180° so that it points in the  
opposite direction 2 to direction 1. Adjust the instru-  
ment so that the laser beam hits point A1 exactly. If  
point B2 is no further than 2 mm away from point B1,  
then the Leica Lino is within tolerance.  
Checking the accuracy of the vertical plumb  
points:  
de  
en  
F
(only Lino P3, Lino P5 and Lino L2P5)  
Place the Lock switch 3 in the "Unlocked" (  
position.  
)
I
Should your Leica Lino be outside of the spec-  
ified tolerance, please contact an authorised dealer-  
ship or Leica Geosystems.  
E
Checking the upper plumb point:  
P
B1  
B2 max. 2 mm  
NL  
DK  
S
Display notices  
1.5 m  
Falling below or exceeding the permissible  
temperature range:  
N
The laser switches off and all symbols flash.  
Outside of the self-levelling range:  
The laser switches off and the symbol of the selected  
function indicator light starts to flash (for L2), or the  
line or point will begin to flash on and off and the  
symbol of the selected function indicator light begins  
to flash (for P3, P5, L2+, L2G+, and L2P5).  
Pendulum locked:  
1
2
FIN  
J
A1  
CN  
ROK  
PL  
HR  
H
Checking the lower plumb point:  
A1  
1
(only Lino L360, L2P5, L2+, L2G+, and L2)  
The laser beam is not levelled and the Lock symbol 7  
lights up.  
2
RUS  
CZ  
GR  
LT  
1.5 m  
max. 2 mm  
B2  
B1  
Set up the laser on its tripod or wall mount bracket  
near point A1 at a minimum distance of 1.5 m from  
point B1. The horizontal laser is aligned in direction 1.  
Mark the laser points A1 and B1 with a pin.  
LV  
EST  
SLO  
SK  
m
Leica Lino 757665i en  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
TR  
de  
en  
F
Care and advice on operation  
Warranty  
Do not immerse the instrument in water. Wipe off dirt  
with a damp soft cloth. Do not use aggressive  
cleaning agents or solvents. Treat the instrument  
with the same care that you would apply to binocu-  
lars or a camera.  
Lifetime Manufacturer's Warranty  
Warranty coverage for the entire usage time of the  
product according to Leica Geosystems International  
Limited Warranty. Free of charge repair or replace-  
ment for all products that suffer defects as a result  
of faults in materials or manufacturing, for the entire  
life of the product.  
I
E
Dropping or violent shaking of the instrument may  
damage it. Check the instrument for any damage  
before using it. Check the levelling accuracy of the  
instrument regularly.  
P
NL  
DK  
S
3 Years no Cost  
Guaranteed service should the product become  
defective and require servicing under normal condi-  
tions of use, as described in the user manual, at no  
additional charge.  
Transport  
N
To safely transport the instrument, set the Lock  
FIN  
J
switch 3 to "Locked" (  
).  
CN  
ROK  
PL  
HR  
H
To receive the "3 years no cost" period, the product  
registration within 8 weeks of the purchase date. If  
the product is not registered, a "2 years no cost"  
period applies.  
RUS  
CZ  
GR  
LT  
LV  
EST  
SLO  
SK  
m
Leica Lino 757665i en  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
TR  
de  
en  
F
Technical data  
L360  
L2P5  
L2  
L2+  
up to 30 m*  
L2G+  
P3  
P5  
Range  
Range with detector  
Levelling accuracy @ 5 m  
Self-levelling range  
up to 60 m  
-
I
1.5 mm  
1 mm  
1.5 mm  
E
3.5° 0.5°  
-
4° 0.5°  
Accuracy of plumb points @ 5 m  
Accuracy of horizontal line @ 5 m  
1.5 mm  
-
1.5 mm  
P
1.5 mm  
-
NL  
DK  
S
Vertical accuracy @ 3 m  
0.75 mm  
1.5 mm  
-
line length  
360°  
Beam divergence  
<180°  
4
<120°  
2
<180°  
-
-
(horizontal)  
Number of laser points  
Number of laser lines  
-
-
3
5
N
vertical,  
horizontal,  
up, down,  
right, left  
FIN  
J
up, down,  
forward,  
right, left  
vertical,  
up, down,  
forward  
Beam direction  
vertical, horizontal  
horizontal  
CN  
ROK  
PL  
HR  
H
515-520 nm,  
laser class 2  
Laser type  
Batteries  
635 nm, laser class 2  
635 nm, laser class 2  
NiMH battery pack  
(rechargeable)  
Type AA  
4 x 1.5 V  
Type AA  
3 x 1.5 V  
Type AA  
Type AA  
3 x 1.5 V  
4 x 1.5 V  
IP 54  
Protection class spray water / dust  
Operating temperature  
Storage temperature  
IP 65  
-10°C to 40°C  
0°C to 40°C  
-10°C to 40°C  
-25°C to 70°C  
117.8 x  
131.7 x 145 x  
96.2 mm  
96 x 91 x  
117.8 x 130.7 x  
75.4 mm  
RUS  
CZ  
GR  
LT  
Dimensions (H x D x W)  
130.7 x  
99.1 x 108.1 x 59.3 mm  
54 mm  
75.4 mm  
1009 g  
Weight without batteries  
Tripod thread  
370 g  
321 g  
370 g  
1/4"  
370 g  
310 g  
320 g  
(with batteries)  
maximum relative humidity 80 % for temperatures up to 31 °C  
Humidity range  
decreasing linearly to 50 % relative humidity at 40 °C  
LV  
EST  
SLO  
SK  
m
Altitude  
Intended environment  
* depending on lighting conditions  
< 3500 m  
Primarily indoor use  
All rights reserved for changes (on drawings, descriptions and technical data).  
Leica Lino 757665i en  
12  
Technical data  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TR  
 
L360  
L2P5  
L2  
L2+  
up to 100 ft*  
L2G+  
P3  
P5  
de  
en  
F
Range  
Range with detector  
up to 200 ft  
-
Levelling accuracy @ 16 ft  
Self-levelling range  
Accuracy of plumb points @ 16 ft  
Accuracy of horizontal line @ 16 ft  
Vertical accuracy @ 10 ft line length  
1/16 “  
0.04 in  
1/16 “  
3.5° 0.5°  
-
4° 0.5°  
I
1/16 “  
-
-
1/16 “  
-
-
E
1/16 “  
P
1/32 “  
<180°  
1/16 “  
360°  
NL  
DK  
S
Beam divergence  
<120°  
2
<180°  
-
-
(horizontal)  
Number of laser points  
Number of laser lines  
-
4
3
5
vertical,  
horizontal,  
up, down,  
right, left  
up, down,  
forward,  
right, left  
N
vertical,  
up, down,  
forward  
Beam direction  
vertical, horizontal  
horizontal  
FIN  
J
515-520 nm,  
laser class 2  
Laser type  
635 nm, laser class 2  
635 nm, laser class 2  
Type AA, 3 x 1.5 V  
CN  
ROK  
PL  
HR  
H
NiMH battery  
pack  
Type AA  
4 x 1.5 V  
Type AA  
3 x 1.5 V  
Type AA  
Batteries Type  
4 x 1.5 V  
(rechargeable)  
Protection class spray water / dust  
Operating temperature  
Storage temperature  
IP 65  
IP 54  
14°F to +104°F  
32°F to +104°F  
14°F to +104°F  
-13°F to +158°F  
5.19 x 5.71 x  
3.79 in  
14.6 x  
3.8 x 3.6 x  
14.6 x  
Dimensions (H x D x W)  
3.9 x 4.25 x 2.3 in  
RUS  
CZ  
GR  
LT  
5.1 x 2.95 in  
2.1 in  
5.1 x 2.95 in  
35.6 oz (with  
Weight without batteries  
Tripod thread  
13.1 oz  
11.3 oz  
13.1 oz  
13.1 oz  
10.9 oz  
11.3 oz  
batteries)  
1/4"  
maximum relative humidity 80 % for temperatures up to 87.8°F  
decreasing linearly to 50 % relative humidity at 104°F  
Humidity range  
LV  
EST  
SLO  
SK  
m
Altitude  
Intended environment  
* depending on lighting conditions  
< 11,400 ft  
Primarily indoor use  
All rights reserved for changes (on drawings, descriptions and technical data).  
Leica Lino 757665i en  
13  
Technical data  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TR  
de  
en  
F
NiMH battery pack L360  
(rechargeable, Art.No.: 790532)  
Permitted use  
Projection of horizontal and vertical laser lines  
and laser points  
Input voltage  
Input current  
Charging time  
7.5 V  
1 A  
I
Prohibited use  
E
Using the product without instruction  
Using outside the stated limits  
P
7 h  
NL  
DK  
S
Deactivation of safety systems and removal of  
explanatory and hazard labels  
Safety instructions  
The person responsible for the instrument must  
ensure that all users understand these directions and  
adhere to them.  
Opening of the equipment by using tools (screw-  
drivers, etc.), as far as not specifically permitted  
for certain cases  
N
FIN  
J
Carrying out modification or conversion of the  
product  
Deliberate dazzling of third parties; also in the  
dark  
Symbols used  
CN  
ROK  
PL  
HR  
H
The symbols used have the following meanings  
WARNING:  
Indicates a potentially hazardous situation or  
an unintended use which, if not avoided, may result  
in death or serious injury.  
ƽ
Inadequate safeguards at the surveying site.  
Limits of use  
CAUTION:  
Refer to section "Technical data".  
RUS  
CZ  
GR  
LT  
ƽ
Indicates a potentially hazardous situation or  
The Leica Lino is designed for use in areas perma-  
an unintended use which,if not avoided, may result in  
minor injury and/or appreciable material, financial  
and environmental damage.  
nently habitable by humans. Do not use the product  
in explosion hazardous areas or in aggressive envi-  
ronments.  
Important paragraphs which must be adhered  
to in practice as they enable the product to be used  
in a technically correct and efficient manner.  
LV  
EST  
SLO  
SK  
m
Leica Lino 757665i en  
14  
Safety instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TR  
 
WARNING:  
de  
en  
F
ƽ
Areas of responsibility  
Empty batteries must not be disposed of with  
Responsibilities of the manufacturer of the original  
equipment Leica Geosystems AG, CH-9435 Heerbrugg  
(for short Leica Geosystems):  
household waste. Care for the environment and take  
them to the collection points provided in accordance  
with national or local regulations.  
I
Leica Geosystems is responsible for supplying the  
product, including the User Manual in a completely  
safe condition.  
Leica Geosystems is not responsible for third  
party accessories.  
The product must not be disposed of with  
the household waste.  
Dispose of the product appropriately  
in accordance with the national regulations  
in force in your country.  
E
P
NL  
DK  
S
Responsibilities of the person in charge of the  
instrument:  
The person in charge of the instrument has the  
following duties:  
Always prevent access to the product by  
unauthorised personnel.  
N
Product specific treatment and waste management  
information can be downloaded from the Leica  
Geosystems home page at  
received from the Leica Geosystems dealer.  
FIN  
J
To understand the safety instructions on the  
product and the instructions in the User Manual.  
To be familiar with local safety regulations  
relating to accident prevention.  
CN  
ROK  
PL  
HR  
H
WARNING  
ƽ
Hazards in use  
Using a battery charger not recommended by  
Leica Geosystems can destroy the batteries. This can  
cause fire or explosions.  
CAUTION:  
ƽ
Watch out for erroneous measurements if the  
RUS  
CZ  
GR  
LT  
instrument is defective or if it has been dropped or  
has been misused or modified.  
Precautions:  
Only use chargers recommended by Leica Geosys-  
tems to charge the batteries.  
Carry out periodic test measurements.  
Particularly after the instrument has been subject to  
abnormal use, and before, during and after important  
measurements.  
LV  
EST  
SLO  
SK  
m
Refer to section "Checking the accuracy of the Leica  
Lino".  
Leica Lino 757665i en  
15  
Safety instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TR  
is encouraged to try to correct the interference by  
one or more of the following measures:  
de  
en  
F
Electromagnetic Compatibility  
(EMC)  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment  
and receiver.  
WARNING:  
ƽ
I
The Leica Lino conforms to the most stringent  
Connect the equipment into an outlet on a circuit  
different from that to which the receiver is  
connected.  
Consult the dealer or an experienced radio/TV  
technician for help  
E
requirements of the relevant standards and regula-  
tions. Yet, the possibility of it causing interference in  
other devices cannot be totally excluded.  
P
NL  
DK  
S
FCC statement (applic. in U.S.)  
WARNING:  
ƽ
This device complies with Part 15 of the FCC Rules.  
Operation is subject to the following two conditions:  
(1) This device may not cause harmful interference,  
and (2) this device must accept any interference  
received, including interference that may cause unde-  
sired operation.  
Changes or modifications not expressly  
approved by Leica Geosystems for compliance could  
void the user’s authority to operate the equipment.  
N
FIN  
J
CN  
ROK  
PL  
HR  
H
This equipment has been tested and found to comply  
with the limits for a Class B digital device, pursuant to  
part 15 of the FCC Rules. These limits are designed to  
provide reasonable protection against harmful inter-  
ference in a residential installation.  
This equipment generates, uses and can radiate radio  
frequency energy and, if not installed and used in  
accordance with the instructions, may cause harmful  
interference to radio communications.  
RUS  
CZ  
GR  
LT  
However, there is no guarantee that interference will  
not occur in a particular installation.  
LV  
EST  
SLO  
SK  
m
If this equipment does cause harmful interference to  
radio or television reception, which can be deter-  
mined by turning the equipment off and on, the user  
Leica Lino 757665i en  
16  
Safety instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TR  
de  
en  
F
Laser classification  
The Leica Lino produces visible laser beams, which are emitted from the instrument:  
I
E
P
NL  
DK  
S
L
i
n
o
L
3
6
0
N
FIN  
J
CN  
ROK  
PL  
HR  
H
It is a Class 2 laser product in accordance with:  
WARNING:  
ƽ
Looking directly into the beam with optical aids  
IEC60825-1 : 2007 "Radiation safety of laser  
products"  
RUS  
CZ  
GR  
LT  
(e.g. binoculars, telescopes) can be hazardous.  
Lino L2G+: IEC 60825-1:2014  
CAUTION:  
ƽ
Looking into the laser beam may be hazardous  
Laser Class 2 products:  
to the eyes.  
Do not stare into the laser beam or direct it towards  
other people unnecessarily. Eye protection is  
normally afforded by aversion responses including  
the blink reflex.  
LV  
EST  
SLO  
SK  
m
Leica Lino 757665i en  
17  
Safety instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TR  
de  
en  
F
Labelling  
L2P5  
Laser Radiation  
Laser Radiation  
Do not stare into the beam  
Do not stare into the beam  
I
Laser class 2  
Laser class 2  
in acc. with IEC 60825-1:2007  
in acc. with IEC 60825-1:2007  
E
Maximum radiation power: <1.0mW c.w.  
Maximum radiation power: <1.0mW c.w.  
Emitted wavelength:  
Beam divergence:  
620-690nm  
180°  
Emitted wavelength:  
Beam divergence:  
620-690nm  
<1.5 mrad  
P
<
NL  
DK  
S
L2  
Laser Radiation  
Do not stare into the beam  
Laser class 2  
N
in acc. with IEC 60825-1:2007  
Maximum radiation power: <1.0mW c.w.  
FIN  
J
Emitted wavelength:  
Beam divergence:  
620-690nm  
<120°  
CN  
ROK  
PL  
HR  
H
L2+  
L2G+  
L360  
Laser Radiation  
Laser Radiation  
Do not stare into the beam  
Do not stare into the beam  
Laser class 2  
Laser class 2  
in acc. with IEC 60825-1:2014  
in acc. with IEC 60825-1:2007  
Maximum radiation power:  
Emitted wavelength:  
Beam divergence:  
<0.7mW  
Maximum radiation power: <1.0mW c.w.  
515-520nm  
Emitted wavelength:  
Beam divergence:  
620-690nm  
<180°  
Pulse Repetition frequency:  
Pulse duration:  
10 kHz  
50 μs  
<
180°  
RUS  
CZ  
GR  
LT  
P3/P5  
Laser Radiation  
Laser Radiation  
Do not stare into the beam  
Do not stare into the beam  
Laser class 2  
Laser class 2  
in acc. with IEC 60825-1:2007  
in acc. with IEC 60825-1:2007  
Maximum radiation power: <1.0mW c.w.  
Maximum radiation power: <1.0mW c.w.  
LV  
EST  
SLO  
SK  
m
Emitted wavelength:  
Beam divergence:  
620-690nm  
Emitted wavelength:  
Beam divergence:  
620-690nm  
<1.5 mrad  
<360°  
Leica Lino 757665i en  
18  
Safety instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TR  
Position of label:  
de  
en  
F
L
i
n
o
I
L
3
6
0
E
P
NL  
DK  
S
N
FIN  
J
CN  
ROK  
PL  
HR  
H
RUS  
CZ  
GR  
LT  
LV  
EST  
SLO  
SK  
m
Leica Lino 757665i en  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety instructions  
TR  
Leica Geosystems AG, Heerbrugg, Switzerland has been certified as being  
equipped with a quality system which meets the International Standards of  
Quality Management and Quality Systems (ISO standard 9001) and  
Environmental Management Systems (ISO standard 14001).  
Copyright Leica Geosystems AG, Heerbrugg,  
Switzerland 2014  
Original text (757665i EN)  
Leica Geosystems AG  
CH-9435 Heerbrugg  
(Switzerland)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lanzar Car Audio Car Stereo System 2 IN 1 CAR AUDIO SYSTEM WITH DVDVCDJPEGMP4MP3WMACD DISC PLAYER AND AM FM STEREO DIGITAL TUNING RADIO User Manual
Lifebreath Ventilation Hood 195TRV User Manual
Lochinvar Boiler 051 211 User Manual
Marley Engineered Products Ventilation Hood 2438 User Manual
Mattel Baby Toy V6235 User Manual
Mazda Automobile 2001 Millenia User Manual
Melissa Automobile Parts 643 040 74 User Manual
Melissa Juicer 744 016 User Manual
Melissa Microwave Oven 753 094 User Manual
Memorex Microcassette Recorder MB2186 User Manual