OUTDOOR HOUSING
WB-1540U
WB-1550U
INSTRUCTIONS
(B) WB-1550U only
For Customer Use:
Enter below the Serial No. which is located on
the body.
Retain this information for future reference.
Model No.
Serial No.
WB-1540U/WB-1550U
LST0267-001C
Download from Www.Somanuals.com. All Manuals Search And Download.
I
INFORMATION FOR USA
For USA and CANADA
Ⅵ INFORMATION
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to
the presence of uninsulated “dangerous voltage”
within the product’s enclosure that may be of
sufficient magnitude to constitute a risk of electric
shock to persons.
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
The exclamation point within an equilateral triangle
is intended to alert the user to the presence of
important operating and maintenance (servicing)
instructions in the literature accompanying the
appliance.
● Consult the dealer or an experienced radio/TV technician for
help.
Ⅵ CAUTION
CHANGES OR MODIFICATIONS NOT APPROVED BY JVC
COULD VOID USER'S AUTHORITY TO OPERATE THE
EQUIPMENT.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1)
THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2)
THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED
OPERATION.
INFORMATION (FOR CANADA) RENSEIGNEMENT
(POUR LE CANADA)
This Class [B] digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe [B] est conforme à la norme
NMB-003 du Canada.
Due to design modification, data given in this instruction
book are subject to possible change without prior notice.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
Thank you for purchasing this product. (These instructions are for WB-1540U/ WB-1550U)
Before beginning to operate this unit, please read the instruction manual careully in order to make sure that the best possible
performance is obtained.
The compatible cameras for each housing are as follows:
Table of Contents
Getting Started
Installation and Connection (WB-1550U)
Table of Contents ...................................................................4
Operating Precautions ...........................................................4
System Example ....................................................................5
VN-C625U and VN-C655U Systems .................................5
TK-C625U/E, TK-C655E and TK-C676E Systems ............5
Installation and Connection (WB-1540U)
Disassembling the Housing ....................................................6
Mounting the Camera ............................................................6
TK-C625U/E ......................................................................6
VN-C625U .........................................................................7
Assembling the Housing ........................................................8
Mounting the Housing to the wall ...........................................8
Disassembling the Housing ................................................. 10
Procedures Before Mounting the Camera ........................... 10
Mounting the Camera ......................................................... 11
TK-C655E and TK-C676E .............................................. 11
VN-C655U ....................................................................... 12
Assembling the Housing ...................................................... 13
Mounting the Housing to the wall ........................................ 13
Others
Specifications ...................................................................... 15
WB-1540U ...................................................................... 15
WB-1550U ...................................................................... 15
Operating Precautions
Ⅵ Depending on the installation environment of this unit, the
life span of the attached camera may decrease significantly.
Give close attention to the installation location (especially if
used continuously under high temperature or in locations
constantly exposed to direct sunlight).
Ⅵ If a ball or bird hits this unit, bringing about some sort of
trouble, consult your dealer or the nearest Victor service
center.
Ⅵ Do not modify this unit yourself. Accidents may result.
Ⅵ Do not install in locations where there may be vibrations or
Ⅵ As the interior of this unit will heat up, be sure to use San
impact. If it falls, it may cause injury or accidents.
Disk (industrial) if loading the CF card to VN-C625U.
Ⅵ Regularly check for the deterioration of attaching parts and
the loosening of the screws caused by vibrations. If it falls, it
may cause injury or accidents.
Ⅵ This unit may stop functioning properly due to natural
hazards as it is to be installed outdoors. To take
photographs properly, be sure to perform daily checks.
Ⅵ Do not install in locations where radiation, X-rays, or
corrosive gases are emitted. Doing so may cause the
camera to malfunction.
Ⅵ Do not install this unit in locations with sharp temperature
changes, such as near air-con compressors or exhaust-
pipes. Condensation may occur inside the attached
combination camera.
Ⅵ Keep all packaging out of the reach of children. If used for
play, it may cause injury or suffocation.
Ⅵ To save energy, switch off the system when not in use.
Ⅵ This installation should be made by a qualified service
person and should conform to all local codes and the
National Electrical Code , ANSI/NFPA 70.
Ⅵ For safety reasons special techniques are necessary for
installation. Consult your dealer regarding installation, and
ensure that it is carried out by a specialist.
Ⅵ Be sure to mount the safety wire for safety purposes. If it
falls, it may cause injury or accidents.
Ⅵ Taking vibrations, mass and wind force into account, ensure
to mount in a location with sufficient strength using solid
anchor bolts. If reinforced or spiral nuts are not tightened
enough, picture blurring may occur on the monitor screen
due to vibration, and in the worst case there is a danger of
falling.
Ⅵ Use at the voltage indicated. A voltage other than that
displayed may result in fire or electric shocks.
Ⅵ This unit supports lightning conduction to the connection
cable to some extent, but not fully. At installation locations
where there may be a lightning hazard, be sure to add an
arrester to the connection cable or take other precautions.
Ⅵ Do not dangle, shake, or hook objects. If too much load is
placed on top, it may fall and cause injury or accidents.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
System Example
VN-C625U and VN-C655U Systems
WB-1540U / WB-1550U
Power Cable
(AC 24V)
Power Cable (DC 12V)
Not in use on this system. (T1)
AC 24 V Power Supply
T1
Coaxial Cable
Monitor
Alarm Cable
LAN Cable
WB-1540U / WB-1550 U(Main Board)
Alarm Device
To TB1
(Connected)
LAN
PC
TO CAMERA
Power Indicator
Red light turns on during power supply.
Fuse T
VN-C625U/655U
Supplied Converter
Unit
To [VIDEO OUT] Terminal
To [ALARM IN/OUT] Terminal
To [POWER INPUT DC 18 V]
Terminal (VN-C655U)
To [POWER INPUT DC 12 V]
Terminal (VN-C625U)
To [10 BASE-T/100 BASE-TX] Terminal
Ceiling Mount of Network Camera
CAUTION:
T1: Not in use on this system. Ensure to bind both ends of cables that are not in use with insulating tape.
T2: Power will not be supplied to this unit and the installed camera when the fuse on the main board burns out. When this
occurs, please consult your nearby JVC dealer as exchange of fuse according to the rating (125 V - 5 A) will be required.
TK-C625U/E, TK-C655E and TK-C676E Systems
Power Cable (DC 12 V)
WB-1540U / WB-1550U
Not in use on this system. (T1)
LAN Cable
Power Cable (AC 24 V)
To Insulated AC 24 V Power Supply
VIDEO INPUT
Coaxial Cable
Communication Cable
T1
TO CAMERA
REMOTE CONTROL UNIT RM-P2580
CAMERA
POSITION
SETUP
POWER
ALARM
MENU
SET
AUTO
F-1
F-2
F-3
KEY LOCK
LENS
SPEED
CAMERA/POSITION
PAN/TILT
CAMERA
POSI-
1
4
2
5
8
3
6
WB-1540U / WB-1550U (Main Board)
TION
OPTION
1
OPTION
2
CLOSE
IRIS
OPEN
FAR
FOCUS
AF
AUTO
PAN
AUTO
PATROL
NEAR
7
9
0
WIDE
ZOOM
TELE
CLEAR
ENTER
/HOME
To TB1
(Connected)
RM-P2580U/E
TO CAMERA
Power Indicator
Red light turns on during power supply.
Fuse T
To [VIDEO OUT/TO CCU] Terminal
To [POWER INPUT
AC 24 V ~] Terminal
To [CONTROL/ALARM IN, OUT] Terminal
Ceiling Mount of Combination Camera
CAUTION:
● Ensure to turn of the power of devices in use before connecting.
Refer to the instruction manual for the combination camera that is supplied with this unit as well during connection and installation.
●
T1: Not in use on this system. Ensure to bind both ends of cables that are not in use with insulating tape.
T2: Power will not be supplied to this unit and the installed camera when the fuse on the main board burns out. When this
occurs, please consult your nearby JVC dealer as exchange of fuse according to the rating (125 V - 5 A) will be required.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Connection (WB-1540U)
Disassembling the Housing
1. Dismantle the gasket and gasket gland
Loosen the 6 Screws B (M4) using a driver, followed by
dismantling the gasket and gasket gland from the lower
housing.
Main Housing Unit
T The 6 Screws B (M4) cannot be totally removed from
the gasket to prevent it from falling off.
2. Dismantle the lower housing
Loosen the 3 Screws A (M4 x 6) using a driver, followed
by dismantling the lower housing from the main housing
unit.
2.
T The lower housing is connected to the main housing
unit using a safety wire.
Screw A (M4 x 6) x 3
Lower Housing
Gasket
CAUTION:
Safety Wire
Pay careful attention to store the dismantled parts and
screws until assembly is complete to prevent them from
being misplaced.
Gasket Gland
1.
Screw B (M4) x 6
TK-C625
Mounting the Camera (TK-C625U/E)
Before mounting.
Interior of Housing
Notch
JVC Mark
Remove the ceiling mount cover of the camera and guide the
cables supplied with WB-1540U through the cover.
T For further details, please refer to the instruction manual of
the camera in use.
1. Connect the AC 24 V output cable to the camera
Connect the AC 24 V output cable of the main board to
the camera’s ceiling mount bracket.
Camera Mounting Bracket
2. Connect other cables
Connect the necessary cables supplied with the housing
(coaxial video cable, communication cable, etc.) to the
ceiling mount.
Safety Wire
Main Board
CAUTION:
● Connect the communication cable to the [ALARM IN/OUT]
and [CONTROL] terminals if necessary. For safety
reasons, ensure to cut off any excess cable and bind using
an insulating tape before use.
Cables
● For further details on connection, please refer to the
instruction manual of the camera in use.
● Ensure to bind connectors of LAN cables and DC 12 V
Power Cable that are not in use with an insulating tape
before use.
2.
Cover
1.
FRONT
Mark
AC 24 V
Output Cable
3. Mount the camera’s ceiling mount to the main
housing unit.
Ceiling Mount
Use the 4 screws supplied (M4 x 20) to mount the ceiling
To [POWER INPUT AC 24 V]
Terminal of Ceiling Mount
mount to the main housing unit.
3.
Screws Supplied
(M4 x 20) x 4
NOTE:
During mounting, align the [D FRONT] Mark of the ceiling
mount with the notch on the camera mount bracket of the
main housing unit.
4.
Camera
4. Mount the camera to the ceiling mount
Follow instructions in the manual of the camera in use to
mount the camera to the ceiling mount.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
VN-C625
Mounting the Camera (VN-C625U)
Screw (M3) x 2
1. Screw (M4) x 4
Preparation
2.
Converter Unit
Mounting Bracket
1. Dismantle the camera mounting bracket
Loosen the screws on the camera mounting bracket (M4,
4 pcs) using a driver to dismantle it.
2. Dismantle the converter unit mounting bracket
Loosen the screws on the converter unit mounting bracket
(M3, 2 pcs) using a driver to dismantle it.
Camera
Mounting
Bracket
4.
3. Mount the converter unit to the housing
Clamp the converter unit using the converter unit
mounting bracket, followed by mounting it to the housing
using the screws (M3, 2 pcs) removed in Step 2.
When mounting, pay attention to the orientation of the
converter unit as shown in the left diagram.
Connector
Main Housing Unit
4. Mount the camera mounting bracket
3.
Mount the camera mounting bracket dismantled in step 1.
to the housing. Mount it exactly to the original position.
Mounting
Before mounting.
Connector
Remove the ceiling mount cover of the camera and guide the
cables supplied with WB-1540U through the cover.
T For further details, please refer to the instruction manual of
the camera in use.
To [POWER INPUT DC 12 V]
Terminal of Ceiling Mount
1. Connect the AC 24 V output cable to the converter unit.
Follow the procedures below to connect the AC 24 V
output cable of the main board on the main housing unit to
the converter unit.
Connect to AC 24 V Output Cable
A Push both ends of the connector as shown in the left
diagram to remove it from the supplied converter unit.
B Cut the Y terminal of the AC 24 V output cable and peel
off about 5 mm of the coating.
C Push the arrow mark using tools such as a flat-head
screwdriver to insert the coating of the AC 24 V output
cable into the connector.
AC 24 V Output Cable
5mm
Press
Press
Connector
1.
Press
Main Board
D Attach the connector to the converter unit.
AC 24 V
To [POWER
Output Cable
2. Mount the Y terminal of the converter unit to the
2.
INPUT DC
12 V]
ceiling mount of VN-C625U.
5mm
Terminal of
Ceiling
Mount
Guide the Y terminal of the converter unit through
the ceiling mount cover, followed by connecting it to
the [POWER INPUT DC 12 V] terminal of
VN-C625U’s ceiling mount.
Connector
Interior of Housing
JVC Mark
Notch
3. Connect other cables
Connect the necessary cables supplied with the housing
(coaxial video cable, alarm signal cable, LAN cable, etc.)
to the corresponding terminals on the ceiling mount.
CAUTION:
●
Connect the communication cable to the alarm terminal if
necessary. In addition, DC 12 V Power Cable is not in use
on this system. For safety reasons, ensure to cut off any
excess cable and bind using an insulating tape before use.
Main Board
Safety Wire
Camera Mounting Bracket
Cover
Cables
● For further details on connection, please refer to the
FRONT Mark
instruction manual of the camera in use.
3.
4.
4. Mount the camera’s ceiling mount to the main
housing unit.
Ceiling Mount
Use the 4 screws supplied (M4 x 20) to mount the ceiling
mount to the main housing unit.
Screws Supplied (M4 x 20) x 4
NOTE:
5.
During mounting, align the [D FRONT] mark of the ceiling
mount with the notch on the camera mount bracket of the
main housing unit.
Camera
5. Mount the camera to the ceiling mount
Follow instructions in the manual of the camera in use to
mount the camera to the ceiling mount.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Connection (WB-1540U)
Assembling the Housing
1. Adhering the desiccant
of the lower housing.
CAUTION:
Main Housing Unit
● Fogging may occur when there are drastic temperature
changes. In this case, continue using without turning off
the power.
Screw A (M4 x 6) x 3
maintain its effectiveness.
• Do not remove it from the bag until you are about to use
it.
• Do not wet it or touch it with wet hands.
• Assemble promptly upon adhering the desiccant.
• Be sure to replace the desiccant during maintenance.
Safety Wire
2.
1.
Lower Housing
2. Mount the lower housing
Mount the lower housing that is dismantled in Step 2.
(A pg. 10) to the main housing unit using the 3 Screws A
(M4 x 6).
Do so by aligning the position marks of the lower housing
and the main housing unit.
Position Mark
Gasket
Desiccant
3.
3. Mount the gasket and gasket gland
Mount the gasket and gasket gland that are dismantled in
Gasket Gland
Step 1. (A pg. 10) of the housing disassembly procedure
to the lower housing using the 6 Screws B (M4).
Screw B (M4) x 6
CAUTION:
● During assembly, ensure that wires and cables are not
caught in the housing.
● Do not exert force unnecessarily on the gasket or twist it
during mounting.
● Check to ensure that the gasket is in close contact with the
camera.
Mounting the Housing to the wall
1. Drill a hole into the wall.
Anchor Bolt
(M8, 35 mm and above)
Drill a hole (R 45 mm) for inserting the connection cable.
(Refer to left fig.)
Washer
Nut
2. Affix anchor bolts onto the wall.
• Affix 4 anchor bolts (M8, 35 mm and above) for attaching
the housing. (Refer to left fig.)
• Affix an anchor bolts for attaching the safety wire, in the
middle (about 60 mm from both ends) of the 2 upper
anchor bolts, 30 mm from the top. (Refer to left fig.)
Safety Wire
3. Mount the safety wire and arm to the wall.
• Mount the safety wire attached to the housing, to the
anchor bolts using the nut and wire.
• Use the nut and wire to mount the housing onto the wall.
Installation Position
1. 2.
152
126
63
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting the Housing to the Wall (continued)
4. Open the cable connection cover
Use provided hexagon wrench to remove the 4 screws
(M3 x 12) from the cable connection cover to open it.
5. Connect each cable
Waterproofing
Connect the necessary cables.
8.
NOTES:
● When connecting to TK-C625U/E, ensure to bind
connectors of LAN cables that are not in use with an
insulating tape before using.
● Ensure to bind the DC 12 V Power Cable that is not in use
on this system with insulating tape.
4.
9.
Screw (M3 x 12) x 4
6. Bind cable using a waterproof tape
Upon connecting, ensure to perform waterproofing
procedures by binding the joint of each cable with a
waterproof (adhesive) tape.
Alarm/Communication Cable
CAUTION:
LAN Cable (Male)
T DC 12 V Power Cable
Coaxial
Video Cable
For safety reasons, turn on the power only upon connecting
all cables.
AC 24 V
Power Cable
7. Fasten the cables in the interior of the arm
When waterproofing is complete, insert the cables into the
upper interior of the arm and fasten using a tape.
7.
8.
Hole
5.
CAUTION:
Waterproofing
When inserting the cables, ensure that all cable connections
are above the cable connection cover (see dotted line in the
left diagram 7.).
Bind with insulating tape
Bind using a waterproof
(adhesive) tape
Failure to do so may cause malfunctions due to penetration
of rain water.
6.
8. Cover the hole and the mounting side of
housing with waterproof seal.
T Not in use on this system.
After the cables have been connected, cover the holes
made in step 1. with waterproof seal. With the Cable
connection cover open, put your hand in and cover the
hole. Cover the mounting side of the housing with
waterproof seal.
NOTE:
● Be sure to perform waterproofing. Seepage of rainwater
may result in malfunction.
● Use GE silicon or its equivalents as the sealing material.
9. Close the cable connection cover
When cable connection is complete, close the cable
connection cover and fasten 4 screws (M3 x 12) removed
in step 4. using the provided hexagon wrench.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Connection (WB-1550U)
Disassembling the Housing
1. Dismantle the gasket and gasket gland
Loosen the 8 Screws B (M4) using a driver, followed by
dismantling the gasket and gasket gland from the lower
housing.
Main Housing Unit
T The 8 Screws B (M4) cannot be totally removed from
the gasket to prevent it from falling off.
Screw A (M4 x 6) x 3
2. Dismantle the lower housing
Loosen the 3 Screws A (M4 x 6) using a driver, followed
2.
by dismantling the lower housing from the main housing
unit.
T The lower housing is connected to the main housing
unit using a safety wire.
Lower Housing
Gasket
Safety Wire
Gasket Gland
1.
Screw B (M4) x 8
Procedures Before Mounting the Camera
1.
2.
1. Dismantle the rubber gasket of the camera’s
ceiling mount
Rubber Gasket (White)
Dismantle the rubber gasket (white) on the same side as
the ceiling mount of the combination camera to be
installed.
2. Dismantle the rubber gasket in the interior of the
camera
Ceiling Mount
Follow the procedures below to remove the rubber gasket
from the interior of the combination camera.
A Turn the camera body cover in the direction as indicated in
the left diagram.
(When the camera body cover is tight and cannot be
turned, do so upon fastening the main unit.)
B Dismantle the camera body cover.
C Dismantle the dome cover.
D Remove the rubber gasket and restore the dome cover and
camera body cover to their original positions.
A
B
Camera
Body
Cover
Camera
Body Cover
CAUTION:
● The combination camera is an enclosed unit. In order to
prevent fogging in the interior of the dome cover, ensure to
remove the rubber gasket (2 types) before use.
● Do not remove the combination camera from the housing
and use it singly after removing the rubber gasket and
installing to the housing. Doing so may cause the camera
to malfunction.
Main Unit
Dome
Cover
C
D
Dome Cover
Rubber
Gasket
Rubber
Gasket
10
Download from Www.Somanuals.com. All Manuals Search And Download.
TK-C655 and TK-C676
Mounting the Camera (TK-C655E and TK-C676E)
Interior of Housing
1. Connect the AC 24 V output cable to the camera
Connect the AC 24 V output cable to the ceiling mount of
the camera to be installed.
JVC Mark
Notch
2. Connect other cables
Connect the coaxial video cable and communication
cables (alarm signal, control terminal, etc.) supplied with
the housing to the ceiling mount.
CAUTION:
● Connect the communication cable to the [ALARM IN/OUT]
and [CONTROL] terminals if necessary. For safety
reasons, ensure to cut off any excess cable and bind using
an insulating tape before use.
Camera Mounting Bracket
● For further details on connection, please refer to the
instruction manual of the camera in use.
● Ensure to bind connectors of LAN cables and DC 12 V
Power Cable that are not in use with an insulating tape
before use.
Safety Wire
Main Board
3. Mount the ceiling mount of the camera to the
main housing unit
Cables
Use the 4 screws supplied to mount the ceiling mount to
2.
3.
the main housing unit.
F Mark
CAUTION:
Ceiling
Mount
1.
During mounting, align the F mark of the ceiling mount with
the notch on the camera mount bracket of the main housing
unit.
AC 24 V Output
Cable
ScrewsSupplied
(4 pcs)
4. Mount the camera to the ceiling mount
4.
Follow instructions in the manual of the camera to be
To [POWER INPUT AC 24 V]
Terminal of Ceiling Mount
installed to mount the camera to the ceiling mount.
Camera
11
Download from Www.Somanuals.com. All Manuals Search And Download.
VN-C655
Installation and Connection (WB-1550U)
Mounting the Camera (VN-C655U)
Screw (M3) x 2
Screw (M4) x 4
Preparation
1.
2.
Converter Unit
Mounting Bracket
1. Dismantle the camera mounting bracket
Loosen the screws on the camera mounting bracket (M4,
4 pcs) using a driver to dismantle it.
2. Dismantle the converter unit mounting bracket
Loosen the screws on the converter unit mounting bracket
(M3, 2 pcs) using a driver to dismantle it.
4.
Camera Mounting
Bracket
3. Mount the converter unit to the housing
Clamp the converter unit using the converter unit
mounting bracket, followed by mounting it to the housing
using the screws (M3, 2 pcs) removed in Step 2.. When
mounting, pay attention to the orientation of the converter
unit as shown in the left diagram.
Main Housing Unit
4. Mount the camera mounting bracket
3.
Mount the camera mounting bracket dismantled in step 1.
to the housing. Mount it exactly to the original position.
Mounting
Before mounting.
Connector
Remove the ceiling mount cover of the camera and guide the
cables supplied with WB-1550U through the cover.
T For further details, please refer to the instruction manual of
the camera in use.
To [POWER INPUT DC 18 V]
Terminal of Ceiling Mount
1. Connect the AC 24 V output cable to the converter unit.
Follow the procedures below to connect the AC 24 V
output cable of the main board on the main housing unit to
the converter unit.
Connect to AC 24 V Output Cable
A Push both ends of the connector as shown in the left
diagram to remove it from the supplied converter unit.
B Cut the Y terminal of the AC 24 V output cable and peel
off about 5 mm of the coating.
C Push the arrow mark using tools such as a flat-head
screwdriver to insert the coating of the AC 24 V output
cable into the connector.
AC 24 V Output Cable
Press
5mm
Press
Connector
1.
Press
D Attach the connector to the converter unit.
Main Board
2. Mount the Y terminal of the converter unit to the
AC 24 V
To [POWER
INPUT DC
18 V]
ceiling mount of VN-C655U.
Output Cable
2.
Guide the Y terminal of the converter unit through the
ceiling mount cover, followed by connecting it to the
[POWER INPUT DC 18 V] terminal of VN-C655U’s ceiling
mount.
5mm
Terminal of
Ceiling
Connector
Interior of Housing
Mount
3. Connect other cables
Notch
JVC Mark
Connect the necessary cables supplied with the housing
(coaxial video cable, alarm signal cable, LAN cable, etc.)
to the corresponding terminals on the ceiling mount.
CAUTION:
●
Connect the communication cable to the alarm terminal if
necessary. In addition, DC 12 V Power Cable is not in use
on this system. For safety reasons, ensure to cut off any
excess cable and bind using an insulating tape before use.
Main Board
Safety Wire
Camera Mounting Bracket
F Mark
● For further details on connection, please refer to the
instruction manual of the camera in use.
Cables
Ceiling Mount
3.
4.
4. Mount the camera’s ceiling mount to the main
housing unit.
Screws Supplied (4 pcs)
Use the screws supplied (4 pcs) to mount the ceiling
mount to the main housing unit.
5.
NOTE:
During mounting, align the
Camera
F
mark of the ceiling mount with the
notch on the camera mount bracket of the main housing unit.
5. Mount the camera to the ceiling mount
Follow instructions in the manual of the camera in use to
mount the camera to the ceiling mount.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Assembling the Housing
1. Mount the desiccant
of the lower housing.
CAUTION:
● Fogging may occur when there are drastic temperature
changes. In this case, continue using without turning off
the power.
maintain its effectiveness.
Main Housing Unit
Screw A (M4 x 6) x 3
• Do not remove it from the bag until you are about to use
it.
• Do not wet it or touch it with wet hands.
• Assemble promptly upon adhering the desiccant.
• Be sure to replace the desiccant during maintenance.
Safety Wire
2.
1.
2. Mount the lower housing
Lower Housing
Position Mark
Mount the lower housing that is dismantled in Step 2.
(A pg. 10) to the main housing unit using the 3 Screw A
(M4 x 6).
Do so by aligning the position marks of the lower housing
and the main housing unit.
Desiccant
Gasket
3.
3. Mount the gasket and gasket gland
Mount the gasket and gasket gland that are dismantled in
Step 1. (A pg. 10) of the housing disassembly procedure
to the lower housing using the 8 Screws B (M4).
Gasket Gland
CAUTION:
Screw B (M4) x 8
● During assembly, ensure that wires and cables are not
caught in the housing.
● Do not exert force unnecessarily on the gasket or twist it
during mounting.
● Check to ensure that the gasket is in close contact with the
camera.
Mounting the Housing to the wall
1. Drill a hole into the wall.
Anchor Bolt
(M8, 35 mm and above)
Drill a hole (R 45 mm) for inserting the connection cable.
(Refer to left fig.)
Washer
Nut
2. Affix anchor bolts onto the wall.
• Affix 4 anchor bolts (M8, 35 mm and above) for attaching
the housing. (Refer to left fig.)
• Affix an anchor bolt for attaching the safety wire, in the
middle (about 60 mm from both ends) of the 2 upper
anchor bolts, 30 mm from the top. (Refer to left fig.)
Safety Wire
3. Mount the safety wire and arm to the wall.
• Mount the safety wire attached to the housing, to the
anchor bolts using the nut and wire.
• Use the nut and wire to mount the housing onto the wall.
Installation Position
1. 2.
152
126
63
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Connection (WB-1550U)
Mounting the Housing to the Wall (continued)
4. Open the cable connection cover
Use provided hexagon wrench to remove the 4 screws
(M3 x 12) from the cable connection cover to open it.
Waterproofing
5. Connect each cable
8.
4.
Connect the necessary cables.
CAUTION:
● Ensure to bind connectors of LAN cables that are not in
use with an insulating tape before use.
● Ensure to bind the DC 12 V Power Cable that is not in use
on this system with insulating tape.
9.
Screw (M3 x 12) x 4
6. Bind cable using a waterproof tape
Upon connecting, ensure to perform waterproofing
procedures by binding the joint of each cable with a
waterproof (adhesive) tape.
Alarm/Communication Cable
LAN Cable (Male)
T DC 12 V Power Cable
Coaxial Video Cable
CAUTION:
AC 24 V
Power Cable
For safety reasons, turn on the power only upon connecting
all cables.
7.
7. Fasten the cables in the interior of the arm
When waterproofing is complete, insert the cables into the
8.
upper interior of the arm and fasten using a tape.
5.
Hole
Waterproofing
Bind with insulating tape
CAUTION:
When inserting the cables, ensure that all cable connections
are above the cable connection cover (see dotted line in the
left diagram).
Bind using a waterproof
(adhesive) tape
Failure to do so may cause malfunctions due to penetration
of rain water.
6.
T Not in use on this system.
8. Cover the hole and the mounting side of
housing with waterproof seal.
After the cables have been connected, cover the holes made
in step 1. with waterproof seal. With the Cable connection
cover open, put your hand in and cover the hole. Cover the
mounting side of the housing with waterproof seal.
NOTE:
● Be sure to perform waterproofing. Seepage of rainwater
may result in malfunction.
● Use GE silicon or its equivalents as the sealing material.
9. Close the cable connection cover
When cable connection is complete, close the cable
connection cover and fasten the 4 screws (M3 x 12)
removed in step 4. using the provided hexagon wrench.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Others
Specifications
WB-1540U
Ⅵ General
Ⅵ Mass: 5.0 kg
Power / Voltage : AC 24 V 50 Hz/60 Hz (Main Housing Unit)
Power Consumption
Ⅵ Accessories:
Instructions...............................1
Desiccant..................................1
Screw (M4×20).........................4
Hexagon wrench.......................1
: 25 W (During heater operation, excluding
camera)
Installation Location
: Outdoor (general)
Ambient Temperature
Ⅵ Compatible Cameras: TK-C625U/E, VN-C625U
Ⅵ Dimensional Outline Drawing (Unit: mm)
: -20 I to 50 I (when equipped with
TK-C625U/E)
294
260
152
126
: -20 I to 40 I (when equipped with
VN-C625U)
Heater Operation Temperature (Internal temperature)
: Heater turns ON between 8 I 5 I
Turns OFF between 20 I 5 I
Ambient Humidity : 35 % to 90 %
Vibration / Shock : Locations without vibration/shock
Dustproof / Waterproof
2-
Ǟ9 hole
: IP66
T When combined with compatible
camera
Ǟ
260
Permissible Wind Speed
: 40 m/s or below
T Specifications and appearance of this unit as well as related
products may be modified for improvement without prior
notice.
WB-1550U
Ⅵ General
Ⅵ Mass: 5.0 kg
Power / Voltage : AC 24 V 50 Hz/60 Hz (Main Housing Unit)
Power Consumption
Ⅵ Accessories:
Instructions...............................1
Desiccant..................................1
Screw (M4×20).........................4
Hexagon wrench.......................1
: 25 W (During heater operating, excluding
camera)
Installation Location
: Outdoor (general)
Ambient Temperature
Ⅵ Compatible Cameras: TK-C676E, TK-C655E, VN-C655U
Ⅵ Dimensional Outline Drawing (Unit: mm)
: -20 I to 50 I (when equipped with
TK-C676E, TK-C655E)
294
260
152
126
: -20 I to 40 I (when equipped with
VN-C655U)
Heater Operation Temperature (Internal temperature)
: Heater turns ON between 8 I 5 I
Turns OFF between 20 I 5 I
Ambient Humidity : 35 % to 90 %
Vibration / Shock : Locations without vibration/shock
Dustproof / Waterproof
2-
Ǟ9 hole
: IP66
T When combined with compatible
Ǟ
260
camera
Permissible Wind Speed
: 40 m/s or below
T Specifications and appearance of this unit as well as related
products may be modified for improvement without prior
notice.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
LST0267-001C
© 2007 Victor Company of Japan, Limited
Download from Www.Somanuals.com. All Manuals Search And Download.
|