Intel Network Card SSR212PP User Manual

®
Intel Storage System  
SSR212PP  
Based on EMC AX150® Technology  
User Guide  
Intel Order Number: D59966-001  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Information  
Important Safety Instructions  
Read all caution and safety statements in this document before performing any of the  
instructions. See also Intel Server Boards and Server Chassis Safety Information on the  
¤
Intel Server Deployment Toolkit CD and/or at  
Wichtige Sicherheitshinweise  
Lesen Sie zun chst s mtliche Warnund Sicherheitshinweise in diesem Dokument, bevor  
Sie eine der Anweisungen ausf hren. Beachten Sie hierzu auch die Sicherheitshinweise zu  
¤
Intel-Serverplatinen und Servergeh usen auf der Intel Server Deployment Toolkit CD  
Consignes de sécurité  
Lisez attention toutes les consignes de s curit et les mises en garde indiqu es dans ce  
document avant de suivre toute instruction. Consultez Intel Server Boards and Server  
¤
Chassis Safety Information sur le Intel Server Deployment Toolkit CD ou bien rendez-  
Instrucciones de seguridad importantes  
Lea todas las declaraciones de seguridad y precauci n de este documento antes de realizar  
cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety  
¤
Information en el Intel Server Deployment Toolkit CD y/o en  
Intel Server Boards and Server Chassis Safety Information  
Intel Storage System SSR212PP User Guide  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Warnings  
Heed safety instructions: Before working with your server product, whether you are  
using this guide or any other resource as a reference, pay close attention to the safety  
instructions. You must adhere to the assembly instructions in this guide to ensure and  
maintain compliance with existing product certifications and approvals. Use only the  
described, regulated components specified in this guide. Use of other products /  
components will void the UL listing and other regulatory approvals of the product and will  
most likely result in noncompliance with product regulations in the region(s) in which the  
product is sold.  
System power on/off: The power button DOES NOT turn off the system AC power. To  
remove power from system, you must unplug the AC power cord from the wall outlet.  
Make sure the AC power cord is unplugged before you open the chassis, add, or remove  
any components.  
Hazardous conditions, devices and cables: Hazardous electrical conditions may be  
present on power, telephone, and communication cables. Turn off the server and  
disconnect the power cord, telecommunications systems, networks, and modems attached  
to the server before opening it. Otherwise, personal injury or equipment damage can  
result.  
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives,  
boards, and other parts. It is recommended that you perform all procedures in this chapter  
only at an ESD workstation. If one is not available, provide some ESD protection by  
wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on  
your server when handling parts.  
ESD and handling boards: Always handle boards carefully. They can be extremely  
sensitive to ESD. Hold boards only by their edges. After removing a board from its  
protective wrapper or from the server, place the board component side up on a grounded,  
static free surface. Use a conductive foam pad if available but not the board wrapper. Do  
not slide board over any surface.  
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips  
over two jumper pins. Some jumpers have a small tab on top that you can grip with your  
fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab,  
take care when using needle nosed pliers to remove or install a jumper; grip the narrow  
sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can  
damage the contacts inside the jumper, causing intermittent problems with the function  
controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool  
you use to remove a jumper, or you may bend or break the pins on the board.  
iv  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel Storage System SSR212PP User Guide  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
vi  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel Storage System SSR212PP User Guide  
vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
viii  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Figures  
Intel Storage System SSR212PP User Guide  
ix  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
x
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
xii  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
About this Manual  
Thank you for purchasing and using the Intel¤ Storage System SSR212PP.  
This manual is written for system technicians who are responsible for installing,  
troubleshooting, upgrading, and repairing this storage system. This document provides a  
brief overview of the features of the product, a list of accessories or other components you  
may need, troubleshooting information, and instructions on how to add and replace  
components on the Storage System SSR212PP . For the latest version of this manual, see  
For information about which accessories, memory, processors, and third-party hardware  
have been tested and can be used with your storage system, and for ordering information  
¤
for Intel products, see  
Additional Information and Software  
If you need more information about this product or information about the accessories that  
can be used with this storage system, use the following resources. These files are available  
indicated in the following table, once on this Web page, type the document or software  
name in the search field at the left side of the screen and select the option to search  
"SSR212PP".  
For this information or software  
Use this Document or Software  
For in-depth technical information  
about this product  
Intel® Storage System SSR212PP Technical Product  
Specification  
If you just received this product  
and need to install it  
Intel® Storage System SSR212PP Quick Start User's  
Guide in the product box  
For virtual system tours and  
interactive repair information  
A link to the SMaRT Tool is available under "Other  
Resources" at the right side of the screen at  
2PP  
Accessories and spares  
Intel® Storage System SSR212PP Spares Installation  
Guide  
Hardware (peripheral boards,  
adapter cards) and operating  
systems that have been tested  
with this product  
Tested Hardware Operating Systems List (THOL)  
Intel Storage System SSR212PP User Guide  
xiii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
xiv  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PlanningYour Fibre Channel  
Storage System  
1
Conguration  
This document is written for administrators who are planning and setting up Fibre  
Channel SSR212PP-Series storage systems. It will help you plan your management port  
network and security login information and storage system disk and switch information.  
For each storage system that you will configure, complete a copy of the enclosed  
worksheets.  
For the most current, detailed, and complete SSR212PP-Series configuration rules  
and sample configurations, refer to the Tested Hardware and OS List (THOL)  
document the SSR212PP support website. For information on how to access this  
website, refer to the support information that shipped with your storage system.  
Topics in this procedure include:  
Intel Storage System SSR212PP User Guide  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Storage System Management Ports  
The storage system can have two management ports, one per storage processor (SP). Plan  
the network and security characteristics for each management port and record the data  
below. Your network administrator should provide this information.  
Provide a static IP address for each storage system MANAGEMENT port.  
SP A MANAGEMENT port ______.______.______.______  
SP B MANAGEMENT port ______.______.______.______  
Subnet mask ______.______.______.______  
Default gateway ______.______.______._____  
Provide a username and password for your storage system.  
Username ________________________  
Password ________________________  
Denitions  
IP address  
The static network IP (Internet Protocol) address (for example,  
128.222.78.10) for communication with a management port of a storage  
processor (SP A or SP B). There is one management port per SP.  
Subnet mask The subnet mask for the local area network (LAN) to which the storage  
system is connected for management, for example, 255.255.255.0.  
Gateway  
The gateway address for the LAN to which the storage system  
management port is connected.  
Username  
A valid username for logging in to the management interface must start  
with a letter and may contain 1 to 32 letters and numbers. The name may  
not contain punctuation, spaces, or special characters. You can use  
uppercase and lowercase characters. Usernames are case-sensitive. For  
example, ABrown is a different username from abrown.  
Password  
A password for logging in to the management interface may contain 1 to  
32 characters, consisting of uppercase and lowercase letters and numbers.  
As with the username, passwords are case-sensitive. For example,  
Azure23 differs from azure23. The password is valid only for the  
username you specified.  
2
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Fibre Channel Switch Information  
If your configuration will use one or more Fibre Channel switches, complete a Switch  
information worksheet for each switch. If your site will not use switches, skip this section,  
Customer-installable SSR212PP-Series switches are easily configured (some are  
preconfigured) so any HBA connected to switch ports other than 0 and 4 communicates  
with storage processors connected to switch ports 0 or 4. With switches set up in such  
"hard zones," you can connect FE 0 or FE 1 to ports 0 and 4 only, and connect HBAs only  
to ports 1, 2, 3, 5, 6, or 7...16.  
Customer-Installable Switch 1 Information  
SP-to-switch connections  
Switch port  
Storage System name  
SP  
SP port  
0
4
SP A __ or SP B __  
SP A __ or SP B __  
FE 0 __ or FE 1 __  
FE 0 __ or FE 1 __  
Switch-to-server HBA connections  
Server name  
Switch port  
HBA name  
1
2
3
4
5
6
7
Customer-Installable Switch 2 Information  
SP-to-switch connections  
Switch port  
Storage System name  
SP  
SP port  
0
4
SP A __ or SP B __  
SP A __ or SP B __  
FE 0 __ or FE 1 __  
FE 0 __ or FE 1 __  
Switch-to-server HBA connections  
Server name  
Switch port  
HBA name  
1
2
3
4
5
6
7
Intel Storage System SSR212PP User Guide  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Sample Switch Information Worksheet  
A sample switch worksheet section follows. It describes one server with two HBAs and  
one storage system with two SPs.  
Customer-Installable Switch 1 Information  
SP-to-switch connections  
Switch port  
Storage System name  
SP  
SP port  
0
SP A X or SP B __  
FE 0 X or FE 1 __  
Storage4  
Storage4  
4
SP A __ or SP B X  
FE 0 X or FE 1 __  
Switch-to-server HBA connections  
Switch port  
Server name  
HBA name  
A0  
1
nlpc5236  
nlpc5236  
2
A1  
If you have multiple servers and two switches, you must connect the HBAs in each server  
to matching switch ports; that is, with two servers, HBA a0 in each server connects to port  
1 on each switch and HBA a1 in each server connects to port 2 on each switch.  
Figure 1 shows two servers, each with two HBAs; two switches; and a storage system  
with two SPs.  
Server B  
Server A  
H
B
H
B
A
H
B
A
H
B
A
A
a0  
a1  
a0 a1  
S
w
i
S
7
6
5
4
7
6
5
4
3
2
1
0
3
2
1
0
w
i
t
t
c
h
2
c
h
1
Por  
Po  
t 1  
rt  
Port 0  
Port 0  
1
Storage  
Processor A  
Storage  
Processor B  
Storage System  
EMC3110  
FIGURE 1.  
HBA and Port Connectivity  
4
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Completing the Switch Information Worksheet  
On the worksheet, for each switch port, indicate the SP or HBA port to which the switch  
port will connect.  
SP-to-Switch Connections  
Specify the SP-to-switch connections. For preconfigured switches, ports 0 and 4 are the  
only two switch ports you can connect to storage system SP ports; if you will use both  
switch ports, specify connections for each. These identify the SP (A or B) and the SP port  
(labeled FE 0 or FE 1) that you will connect to each switch port.  
Switch-to-Server-HBA Connections  
Specify switch-to-server connections here for any of the switch ports (1, 2, 3, 5, 6, 7...16  
in preconfigured, switches) that you will connect to a server HBA. Specify the server  
name and HBA name, if you plan to the HBA using Navisphere¤ software.  
If you have a second switch, specify the connections you will make to that switch.  
Intel Storage System SSR212PP User Guide  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Storage System Disk Information  
This section defines storage system disk information. Fill out the following worksheet as  
described in this section.  
Disk Information  
Disk Pool  
Virtual Disk  
Number  
(1- 6 or  
Spare)  
Disks to  
Form Pool Capacity  
(1-12)  
Free  
Capacity Space  
Function (Gbytes) (Gbytes) Assigned  
Server  
To Be  
(Gbytes) Name  
Use this worksheet to list the disk pools and virtual disks that you will create. A sample  
worksheet section and information about completing the columns in it follows. The  
sample worksheet shows that 20- and 38-Gbyte virtual disks have been reserved for  
expansion of virtual disks in the three disk pools. The storage system described in the  
worksheet has 250-Gbyte disks (not 500-Gbyte disks).  
Disk Information  
Disk Pool  
Virtual Disk  
Number Disks to  
Free  
Space  
(Gbytes)  
Server  
(1- 6 or  
Spare)  
Form Pool  
(1-12)  
Capacity  
(Gbytes) Name  
Capacity  
(Gbytes)  
To Be  
Function  
Assigned  
1
0, 1, 2, 3 651 Vdisk1 Users A-N  
315  
20  
PC1234  
Vdisk2 Users O-Z 316  
2
3
4, 5, 6, 7 690 Vdisk3 Database  
660  
440  
38  
20  
8, 9, 10  
11  
460 Vdisk4  
Mail  
Spare  
Number (1-6 or spare)  
You must create at least one disk pool for virtual disks. You can create up to four RAID 5  
disk pools or six RAID 1/0 disk pools, numbered 1-6, in a storage system.  
6
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
If your system has two SPs, you should create at least two disk pools, since the software  
assigns one or more disk pools to each SP; that is, it assigns disk pool 1 and all its virtual  
disks to SP A, disk pool 2 and all its disks to SP B, disk pool 3 and its disks to SP A, and  
disk pool 4 and its disks to SP B. If you create only one pool, all virtual disks in the  
storage system will be assigned to SP A.  
Disks to form each pool  
For each pool, specify the numbers of the disks you will include. The number of disks in a  
pool determines its capacity. Generally, we suggest no more than six; the minimum is  
three for RAID 5 and two for RAID 1/0 pools.  
For maximum use of space on the disks, it is recommended that you do not combine disks  
0 through 3 (the operating system disks) in a disk pool with other disks. Part of the space  
on the operating system disks is preloaded with system data, and as a result, is not  
available for your data. If you combine operating system disks in a disk pool with other  
disks, each of the other disks loses space for data equal to the system data space on an  
operating system disk.  
If you have disks of differing capacities (for example, 250- and 500-Gbyte), always use  
disks of the same capacity when creating a disk pool. If the disks have different capacities,  
the software will format each disk at the smaller of the two disk sizes, wasting more than  
200 Gbytes of potential storage on each larger disk.  
When you create disk pools, consider making one disk a hot spare. A hot spare allows  
your system to continue running with its normal performance and retain its redundancy if  
a disk fails. However, because a hot spare is reserved as a replacement disk, it cannot be  
used as a virtual disk. You may not want to devote an entire disk to maintaining  
redundancy after a disk failure.  
If you create disk pools that use all the storage system disks, no space will remain for a hot  
spare. Later, if you need to create a hot spare, you must delete all the virtual disks in the  
disk pool, delete the pool, create a new pool, and then create the hot spare and new virtual  
disks on the new pool.  
Always use a disk with the largest capacity as a hot spare. You can make any disk other  
than 0, 1, 2, or 3 a hot spare. If you decide to use a hot spare, write "Spare" in the  
appropriate row in column 1 and the disk number in column 2.  
If you want to create disk snapshots, that is, capture point-in-time images of a virtual disk,  
then you must reserve disk space for snapshot disk resources. The snapshot resource uses  
this space transparently for snapshot operations, but the space must be available and not  
allocated to any virtual disk. The snapshot resource requires a maximum of 20 percent of  
each virtual disk whose point-in-time images you will capture, allocated in 10-Gbyte  
blocks. For example, if you will take snapshots of a 290-Gbyte virtual disk, leave 60  
Gbytes of disk space unused. Twenty percent of 290 is 58, but space is given in 10-Gbyte  
blocks; therefore you must reserve 60 Gbytes.  
From Disk 0 through Disk 11, select the disks that you want to include in the disk pool,  
and select a disk to be a Hot Spare. Record this information in the Storage System disk  
information worksheet.  
Intel Storage System SSR212PP User Guide  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disk pool capacity (Gbytes)  
To calculate the size of a RAID 5 disk pool, multiply the number of disks less 1 (n-1) by  
the disk capacity. For a RAID 1/0 disk pool, multiply the number of disks by the disk  
capacity, then divide by 2. The following table shows the formatted capacity of  
SSR212PP-Series disks.  
250 Gbyte Disks  
500 Gbyte disks  
217 Gbytes per disk  
230 Gbytes per disk  
458 Gbytes per disk  
445 Gbytes per disk  
Disks 0-3  
Disks 4-11  
Name  
Name the virtual disks in each disk pool. You can include up to 128 virtual disks in a disk  
pool. The default virtual disk name is Virtual Disk n, where n is the sequential number,  
starting with 1. However, you can substitute a more meaningful name, such as Users or  
Mail. You can choose to have multiple applications on the same virtual disk.  
If you will have more than one disk pool, try to place the same number of virtual disks in  
each pool. Or, if you know that one or more virtual disks will be accessed often, you might  
choose to place these on their own SP. For example, you might place a heavily accessed  
virtual disk, such as a database, by itself on disk pool 2, attached to SP B; and place other,  
lightly accessed virtual disks in disk pool 1, attached to SP A.  
Function  
Describe the purpose of the virtual disk.  
Virtual disk capacity (Gbytes)  
Determine the capacity of each virtual disk in the disk pool. The combined capacity of all  
virtual disks cannot exceed the available space of the parent disk pool.  
Decide how much space in the disk pool should be free space. Generally, you should leave  
a modest amount of free space, such as 10 percent of the disk pool size, in each pool. Then  
you can expand any of the virtual disks in the pool up to the amount of reserved space.  
Free space (Gbytes)  
Enter the amount of free space you want to reserve for expansion. Note this space is  
available to all virtual disks in the disk pool; that is, if there are multiple virtual disks in  
the pool, you can allocate part or all of the free space to one virtual disk or among several  
disks.  
If you do not reserve adequate free space in a disk pool, and you need more space  
on a virtual disk in the pool, you must back up the data in the pool, destroy the pool,  
create a new pool with a larger virtual disk, and then reload the data.  
Server to be assigned (assigned servers)  
You will need to specify each assigned server when you create the virtual disk. Write the  
server hostname here. The maximum number of servers you can connect to one storage  
system is ten.  
8
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Fibre Channel  
Storage System  
2
This procedure describes the process of connecting an SSR212PP-Series Fibre Channel  
storage system (SSR212PPf or SSR212PP2f) to a Microsoft Windows¤ or Linux server in  
one of these methods:  
through one or two Fibre Channel switches.  
directly.  
Terminology  
host  
A computer that is or will be connected to an SSR212PP-Series storage  
system. This computer is called either a management host or a server,  
depending on how it is or will be connected to the storage system.  
management host  
A host from which you manage SSR212PP-Series storage systems. It  
must be on the same LAN as the storage system management ports. A  
management host may also be a server.  
server  
A host that is already or will be connected directly to the Fibre Channel  
ports on an SSR212PP-Series storage system. A management host may  
also be a server.  
existing server The server that is already configured for and connected to an SSR212PP-  
Series storage system.  
new server  
A server that is not already connected to or set up for an SSR212PP-  
Series storage system.  
existing HBA The host bus adapter (HBA) that is already installed in a server.  
new HBA The HBA that was not already installed in the server.  
existing storage system  
An SSR212PP-Series storage system that is already connected to a server  
and configured for storage.  
new storage system  
A storage system that is not connected to a server or configured for  
storage. It is just as it was shipped to you.  
eld-replaceable unit (FRU)  
A storage system component that you can add to your storage system or  
replace in your storage system at your site. Examples of FRUs are disks,  
power supplies, memory cards, and power supplies.  
Intel Storage System SSR212PP User Guide  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
storage processor (SP)  
A printed-circuit board with processors, memory modules, and control  
logic that manages the I/O between the server and the disk modules.  
disk pool  
A set of disks with the same capacity and RAID type on which you create  
one of more virtual disks.  
virtual disk  
A grouping of physical disk partitions into one span of disk storage space.  
Each virtual disk you create is distributed equally across the disks in the  
disk pool. A virtual disk looks like an individual disk to the server s  
operating system.  
An SSR212PPf storage system has one SP, so it is called a single-SP system. An  
SSR212PP2f storage system has two SPs, so it is called a dual-SP system.  
BeforeYou Start  
Review Tested Hardware and OS List (THOL) on the SSR212PP support website to  
confirm that the following are supported:  
The server hardware that will access the storage system.  
The operating system version running on the server hardware.  
For a new storage system installation, you will need:  
An SSR212PPf or SSR212PP2f storage system and the cables, rails and CDs that ship  
with it.  
For an SSR212PP2f (dual-SP system), an uninterruptible power supply (UPS) kit,  
including the power cords, UPS serial cable, and mounting hardware.  
Standard AC power for each power supply in the storage system from an independent  
AC source or a cabinet/rack power distribution unit.  
A CAT 5 or higher LAN cable for the management port on each SP. If your  
configuration includes Fibre Channel switch(es) and you plan to use the switch  
management software, you will also need a CAT 5 or higher LAN cable for each  
switch.  
The following management port network information, which the person responsible  
for your network should provide:  
Static IP address for each SP in the storage system.  
Subnet mask for the LAN to which you will connect the storage system.  
Default gateway for the LAN to which you will connect the storage system.  
For any installation, you will need:  
A management host with a supported Internet browser for running Navisphere¤  
Express and on the same network as the storage system management ports. This host  
10  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
can also be the server. For supported hosts and browsers, refer to Tested Hardware  
and OS List (THOL) on the SSR212PP support website.  
A Linux or Windows host that is or will be a server with Fibre Channel connections to  
the storage system. This server must have all required updates, such as hot fixes or  
patches, installed. For supported hosts and required updates, refer to Tested Hardware  
and OS List (THOL) on the SSR212PP support website.  
One or more supported QLogic¤ or Emulex¤ Fibre Channel host bus adapters  
(HBAs), which may already be installed in the server. These adapters must have the  
latest supported BIOS and driver. For information on supported HBAs, BIOS, and  
drivers, refer to Tested Hardware and OS List (THOL) on the SSR212PP support  
website.  
Never mix Fibre Channel HBAs from different vendors in the same server.  
An optical cable for each storage-processor (SP) Fibre Channel port you will use on  
the storage system. (Each storage processor has two ports.) These cables may already  
be connected for a configuration with an existing storage system or server.  
A method for writing data to a virtual disk on the storage system to test the path from  
a new HBA to the storage system.  
The Installation Procedure  
STEP 3. Install the Navisphere Server Utility. See Procedure 9, "Installing the Navisphere Server  
STEP 4. If you have an SSR212PP2f system, install the UPS:  
CAUTION  
You must install the UPS that shipped with your storage system. You cannot use  
any other type of UPS.  
a. Unpack the UPS and save the packaging. Verify that the cables and mounting kit were  
included.  
b. Install the UPS in a 19-inch NEMA-standard cabinet/rack, as described in the  
documentation provided with the UPS.  
Intel Storage System SSR212PP User Guide  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CAUTION  
The UPS ships with the battery cable disconnected. Be sure to connect this cable  
firmly when you install the UPS. If this cable is not securely connected, the  
Replace Battery light turns on.  
STEP 7. If you received a second power supply for your single-SP storage system, follow  
You may receive a second power supply that looks slightly different from the  
original, and/or different from the illustrations in this note. The two versions are  
functionally the same.  
STEP 8. If you received disks modules that are not already installed in the storage system, follow  
STEP 9. If you are utilizing Fibre Channel switches, install them in the rack.  
STEP 10. Connect the storage system to AC power.  
page 91 when installing an SSR212PPf (single-SP) storage system.  
when installing an SSR212PP2f (dual-SP) storage system.  
connect the management ports.  
STEP 12. Install the Navisphere Storage System Initialization Utility. See Procedure 17, "Installing  
STEP 13. Verify that the storage system is powered up completely:  
a. The Fault lights on each SP must be off and the Power light must be on. These lights  
are on the rear of the storage system (Figure 2 or Figure 3).  
12  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Power Supply A Fault LED  
Power Supply A On  
Power LED  
Power On/Off Button SP A Boot/Fault LED  
EMC3285  
FIGURE 2.  
SSR212PPf Storage System Rear Lights (LEDs)  
Power Supply B Fault LED  
PS B On  
Power Supply A Fault LED  
PS A On  
SP B Boot/Fault LED  
Power LED  
Power On/Off Button  
SP A Boot/Fault LED  
EMC3272  
FIGURE 3.  
SSR212PP2f Storage System Rear Lights (LEDs)  
b. The amber system Fault light visible from the front of the storage system must be off  
(Figure 4).  
Fault  
Power  
Disk Activity  
SAB2934  
Lock  
FIGURE 4.  
Storage System Front Lights (LEDs)  
STEP 14. Run the Navisphere Storage System Initialization Utility. See Procedure 18, "Running the  
Intel Storage System SSR212PP User Guide  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
PlanningYour iSCSI Storage  
3
System Conguration  
This document is written for administrators who are planning and setting up iSCSI  
SSR212PP-Series storage systems. It will help them plan an internet SCSI (iSCSI) storage  
system configuration, and includes management port, iSCSI port, initiator iSCSI port, and  
disk information. This document also contains information on planning and setting up the  
optional Challenge Handshake Authentication Protocol (CHAP) security system common  
to iSCSI configurations on shared networks.  
For the most current, detailed, and complete configuration rules and sample  
configurations, refer to the Tested Hardware and OS List (THOL) document the  
SSR212PP support website. For information on how to access this website, refer to  
the support information that shipped with your storage system.  
Topics in this document include:  
Intel Storage System SSR212PP User Guide  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Introduction  
SSR212PP-Series iSCSI storage systems connect to servers through Internet SCSI (iSCSI)  
interfaces. Storage systems and servers can connect directly from one iSCSI port to  
another, or through an IP (Internet Protocol) network. iSCSI host bus adapters (HBAs) or  
network interface cards (NICs) in the servers act as the physical iSCSI interfaces.  
You must identify the network settings for each iSCSI I/O port in a storage system,  
including the IP address, subnet mask, and gateway address. These settings define the  
targets of input from the servers in your environment. You must also identify network  
settings for the iSCSI I/O ports in servers that connect to the storage system; these settings  
define the initiators of I/O between servers and the SSR212PP2i and SSR212PPi storage  
systems.  
In some contexts, iSCSI documentation refers to the servers and storage systems  
themselves as initiators and targets, respectively.  
Terminology  
In this document, we use the terms initiator, target, server, and storage system as follows:  
Initiator  
A port on a NIC or iSCSI HBA that issues I/O requests to a target in the  
storage system. NICs and HBAs are installed on the environment s  
servers.  
Target  
A storage system port (target portal) that accepts and responds to requests  
from an initiator. In iSCSI systems the targets, called front-end, or data,  
ports, are on storage processors.  
Server  
A host connected (directly or through a network router or switch) to the  
front-end (data) ports on SSR212PP-Series storage systems. A server can  
also be a management station.  
Storage system Your SSR212PP2i and SSR212PPi storage system.  
iSNS  
You can use the Internet Storage Naming Service (iSNS) on Windows platforms that are  
part of an iSCSI configuration. iSNS requires an iSNS server on the storage network and a  
client storage system; other hosts connected to the storage system are also iSNS clients.  
The iSNS server acts as the repository where hosts and storage devices register their lists  
of initiators and targets. Each individual initiator or target registers its components with  
the iSNS server; the server then answers the initiator s queries for devices with the list of  
registered targets. Discovery domains implemented on the server restrict what targets an  
initiator sees.  
CHAP  
To prevent unauthorized access to the storage system, you can set up CHAP (Challenge  
Handshake Authentication Protocol) authentication for both the initiator and the target.  
For CHAP authentication, you specify a username and password (called a secret) that any  
initiator must use to connect to the target through the iSCSI ports; the target authenticates  
16  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
the initiators. To increase the level of security, you can also set up mutual CHAP  
authentication where initiators authenticate targets, thereby ensuring that the correct  
initiators are connecting to the correct targets.  
Planning worksheets  
For each storage system that you will configure, complete a copy of the enclosed  
worksheets and store it in a safe location. While working with this document and planning  
your configuration, refer to the Tested Hardware and OS List (THOL) document the  
SSR212PP support website for storage system configuration rules and sample  
configurations.  
CAUTION  
All of your security efforts will be nullified if you leave any completed  
worksheets in public places. Store them in a secure place.  
Intel Storage System SSR212PP User Guide  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iSCSI Conguration Rules  
Refer to this section as you plan your iSCSI environment with your network administrator.  
It provides minimal guidelines for configuring initiator servers and target storage systems  
in IP networks that use the iSCSI protocol. It is recommended to use discrete networks  
dedicated to iSCSI data traffic, but support other configurations.  
CAUTION  
The number and complexity of supported configurations is constantly growing.  
The rules and examples shown in this document are a subset of those in the more  
complete, current, and detailed Tested Hardware and OS List (THOL) document  
the SSR212PP support website.  
Login Limitations  
Initiator software  
Supported logins  
MIcrosoft iSCSI initiator  
QLogic SANsurfer  
1 login per server to each SP data port  
1 login per HBA to each SP data port  
Supported Network Devices  
SSR212PP-Series storage systems support industry-standard switches and routers.  
Initiators can connect to target iSCSI storage systems using a Layer 2 (switched) or  
Layer 3 (routed) network.  
VLANs and/or VPNs in the network should be transparent to the storage system and  
are supported as long as the network quality is adequate.  
Supported Server Devices  
You can attach an SSR212PP-Series iSCSI storage system to Microsoft Windows  
2000 and Microsoft Windows Server2003 servers that run the native iSCSI  
Microsoft-certified driver for NICs. Supported devices include both onboard NICs in  
Microsoft-certified servers and Microsoft-certified PCI-based NICs.  
You can attach an SSR212PP-Series iSCSI storage system to Microsoft Windows  
2000, Microsoft Windows Server 2003, and Linux servers that use QLogic  
QLA4010 HBAs and drivers.  
You can attach an SSR212PP-Series iSCSI storage system to qualified Linux servers  
that use the CiscoLinux driver. Supported devices include both onboard and PCI-  
based NICs.  
You can configure SSR212PP-Series iSCSI storage systems with iSNS servers and  
clients.  
You can connect up to four SSR212PP-Series iSCSI storage systems to a single server.  
An SSR212PP2i storage system can connect to a maximum of 20 initiators or a  
maximum of 10 servers (hosts); an SSR212PPi can connect to a maximum of 10  
initiators or a maximum of 10 servers.  
18  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
You can connect up to four iSCSI HBAs or 4 NIC initiators (2 two-port NICs or 4  
one-port NICs) in a server to one SSR212PP2i storage system. SSR212PPi systems  
support connection to 4 iSCSI HBAs 1 two-port NIC, or 2 one-port NICs.  
You cannot use both iSCSI HBAs and NICs in a single server.  
Separate servers with HBAs and servers with NICs can connect to the same storage  
system.  
Environment and Congurability  
A single host cannot attach to an EMC CLARiiONCX-series and an SSR212PP-  
Series iSCSI storage system at the same time.  
For proper traffic routing in an environment that uses physically separated networks,  
each network must use a unique sub-network address.  
This rule applies to both directly-connected configurations and those that use  
dedicated subnets for the data paths.  
When using multiple NICs in a server (host), each card should be on a different  
subnet. The default Microsoft iSCSI Initiator configuration ignores additional cards  
on the same subnet, which require use of the Advanced Log On procedure.  
The Cisco Linux iSCSI driver does not support multiple NICs/HBAs on the  
same subnet. Storage systems connected to Linux servers must configure  
each storage-processor port on a different subnet.  
Intel Storage System SSR212PP User Guide  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration Worksheet  
The accompanying Administration Worksheet contains the following blanks that you will  
need to fill in:  
Storage system management port  
Storage system iSCSI port  
Initiator iSCSI port  
Storage System Management Ports  
The storage system can have two management ports, one per storage processor (SP). Plan  
the network and security characteristics for each management port and record the data on  
the accompanying Administration Worksheet. Use the A section to record network  
information for the management interface. Your network administrator should provide this  
information.  
IP address  
The static network IP (Internet Protocol) address (for example,  
128.222.78.10) for communication with a management port of a storage  
processor (SP A or SP B). Each SP has one management port. Make sure  
that your assigned addresses do not conflict with other devices on the  
corporate network.  
Subnet mask The subnet mask for the local area network (LAN) to which the storage  
system is connected for management, for example, 255.255.255.0.  
Gateway  
The gateway address for the LAN to which the storage system  
management port is connected.  
Username  
A valid username for logging in to the management interface must start  
with a letter and may contain 1 to 32 letters and numbers. The name may  
not contain punctuation, spaces, or special characters. You can use  
uppercase and lowercase characters. Usernames are case-sensitive. For  
example, ABrown is a different username from abrown.  
Password  
A password for logging in to the management interface may contain 1 to  
32 characters, consisting of uppercase and lowercase letters and  
SSR212PP-Series numbers. As with the username, passwords are case-  
sensitive. For example, Azure23 differs from azure23. The password is  
valid only for the username you specified.  
Storage System iSCSI Data Ports  
Plan the network and security characteristics for each iSCSI data port and record the data  
in the B section on the Administration Worksheet. Use the DATA port section to record  
network information for the iSCSI data ports. Your network administrator should provide  
this information.  
IP address  
The static network IP address of the storage system port (for example, 128.222.78.10).  
This is a iSCSI data port on SP A or SP B. Each SP has two iSCSI data ports.  
It is recommended to use these standard Internet addresses for private networks between  
iSCSI data ports and their corresponding network interface cards and/or host bus adapters:  
20  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Class A: 10.0.0.0 - 10.255.255.255  
Class B: 172.16.0.0 - 172.31.255.255  
Class C: 192.168.0.0 - 192.168.255.255  
Make sure that your assigned addresses do not conflict with other devices on the corporate  
network.  
Each NIC or HBA in your server requires a unique IP address. In a server with multiple  
NICs/HBAs attached directly to the storage system, or on a dedicated iSCSI network, the  
initiator ports must be on separate subnets.  
For example, an SSR212PP2i storage system directly attached to network interface cards  
in one or two servers could assign network identifiers as follows:  
Port  
IP address  
Subnet mask  
Gateway  
172.31.1.100  
(1 = subnet)  
255.255.255.0  
0.0.0.0  
Storage Processor A  
iSCSI port  
172.31.1.101  
172.31.2.100  
255.255.255.0  
255.255.255.0  
0.0.0.0  
0.0.0.0  
iSCSI NIC/HBA 1  
Storage Processor B  
iSCSI port  
172.31.2.101  
255.255.255.0  
0.0.0.0  
iSCSI NIC/HBA 2  
Subnet mask  
The subnet mask for the LAN subnet to which the iSCSI data port is connected.  
Gateway  
The default gateway address for the LAN to which the iSCSI data port is connected. If you  
do not have a gateway, set the field to 0.0.0.0; do not leave the field blank.  
Initiator iSCSI Data Ports  
An SSR212PPi (single storage processor) storage system supports as many as 10  
initiators; an SSR212PP2i (dual storage processor) storage system can support 20  
initiators. Record the following initiator information for as many as 20 initiators in the C  
section on the Administration Worksheet.  
Port Name  
This field is not mandatory, but you might find it useful to have a self-determined  
identifier, especially in configurations with multiple iSCSI ports; for example,  
srvr1NIC3prt0.  
IP Address for iSCSI Initiator Port  
The network IP (Internet Protocol) address of the initiator port. See the addressing  
recommendations in "IP address" on page 20.  
The initiator port addresses are not the related to the public IP address of the server  
in which initiator ports reside.  
Intel Storage System SSR212PP User Guide  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Subnet Mask for iSCSI Initiator Port  
The subnet mask for the LAN to which the initiator port is connected.  
Default Gateway for iSCSI Initiator Port  
The default gateway address for the LAN to which the initiator port is connected. This  
parameter does not apply to a system with a direct connection.  
22  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sample SSR212PP2i and SSR212PPi Congurations  
The following examples show viable iSCSI configurations in order of increasing  
complexity. Use them to design your own iSCSI environment. For example, you need to  
determine whether you want to connect your iSCSI storage system directly to a server, set  
up a dedicated iSCSI LAN for the storage system and its iSCSI initiators (a recommended,  
simple configuration) or include the iSCSI storage system in a shared configuration that  
requires more network expertise and potentially complex Challenge Handshake  
Authentication Protocol (CHAP) security. (Note that to avoid system downtime, you  
should set up and enable CHAP before your servers and the iSCSI storage system begin  
exchanging data.)  
This section describes the following sample configurations:  
Intel Storage System SSR212PP User Guide  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SSR212PPi Directly Connected to One Server  
Figure 5 shows one server, with two iSCSI initiators, directly cabled to an SSR212PPi s  
iSCSI data ports.  
Server with separate iSCSI NIC and public NIC  
Corporate,  
public or private  
network  
DAS iSCSI  
iSCSI traffic  
and public LAN  
Management traffic  
SSR212PPi  
EMC3311  
FIGURE 5.  
SSR212PPi (Single SP) Directly Connected to One Server  
Sample IP Addresses  
Port  
IP address  
Subnet mask  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
Gateway  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
Storage Processor A iSCSI port 0  
Storage Processor A iSCSI port 1  
iSCSI NIC/HBA 1  
172.31.1.150  
172.31.2.150  
172.31.1.101  
172.31.2.101  
iSCSI NIC/HBA 2  
Management port IP addresses should match the corporate network scheme.  
Advantages  
You can easily migrate this low-cost storage for a single server to a switched  
environment.  
The dedicated iSCSI path ensures maximum throughput from the host to the storage  
system.  
The dedicated path provides inherent security.  
Disadvantages  
Since only one server can connect to the storage system, this configuration does not  
take full advantage of the SSR212PPi s connectivity capabilities.  
While this configuration provides port failover and load balancing, it does not allow  
SP failover.  
24  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
SSR212PPi Directly Connected to Two Servers  
Figure 6 shows two servers, each with an iSCSI initiator directly cabled to an iSCSI data  
port on the SSR212PPi.  
Servers with separate iSCSI NIC and public NIC  
Corporate,  
public or private  
network  
DAS iSCSI  
and public LAN  
iSCSI traffic  
iSCSI traffic  
Management traffic  
SSR212PPi  
EMC3312  
FIGURE 6.  
SSR212PPi (Single SP) Directly Connected to Two Servers  
Sample IP Addresses  
Port  
IP address  
Subnet mask  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
Gateway  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
Storage Processor A iSCSI port 0  
Storage Processor A iSCSI port 1  
iSCSI NIC/HBA 1  
172.31.1.150  
172.31.1.151  
172.31.1.101  
172.31.1.102  
iSCSI NIC/HBA 2  
Management port IP addresses should match the corporate network scheme.  
Advantages  
You can easily migrate this low-cost storage for two servers to a switched  
environment.  
The dedicated iSCSI path ensures maximum throughput from the host to the storage  
system.  
Since two servers can connect to the storage system, this configuration takes  
advantage of the SSR212PPi s port connectivity capabilities.  
The dedicated paths provide inherent security.  
Disadvantages  
One storage processor does not allow for failover in case of SP failure.  
A single path from each server prohibits failover or load balancing.  
SSR212PP2i Directly Connected to One Server  
Figure 7 shows one server, with four iSCSI initiators, directly cabled from the server to  
each of the SSR212PP2i s iSCSI data ports.  
Intel Storage System SSR212PP User Guide  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Server with separate iSCSI NIC and public NIC  
Corporate,  
public or private  
network  
DAS iSCSI  
and public LAN  
iSCSI traffic  
iSCSI traffic  
Management traffic  
SSR212PP2i  
(dual SP)  
EMC3314  
FIGURE 7.  
SSR212PP2i (Dual SP) Directly Connected to One Server  
Sample IP Addresses  
Port  
IP address  
Subnet mask  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
Gateway  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
Storage Processor A iSCSI port 0  
iSCSI NIC/HBA 1  
172.31.1.150  
172.31.1.101  
172.31.2.150  
172.31.2.101  
172.31.3.150  
172.31.3.101  
172.31.4.150  
172.31.4.101  
Storage Processor A iSCSI port 1  
iSCSI NIC/HBA 2  
Storage Processor B iSCSI port 0  
iSCSI NIC/HBA 3  
Storage Processor B iSCSI port 1  
iSCSI NIC/HBA 4  
Management port IP addresses should match the corporate network scheme.  
Advantages  
You can easily migrate this low-cost storage for a single server to a switched  
environment.  
Redundant paths to the SSR212PP2i provide better failover capabilities. They sustain  
access to the storage system in the event of an iSCSI initiator, cable, or data port  
failure.  
The dedicated iSCSI path ensures maximum throughput from host to storage system.  
Disadvantages  
Since only one server can connect to the storage system, this configuration does not  
take full advantage of the SSR212PP2i s connectivity capabilities.  
A single server does not allow for expansion.  
SSR212PP2i Directly Connected to Two Servers  
Figure 8 shows two servers, each with two iSCSI initiators, directly cabled to the iSCSI  
data ports on an SSR212PP2i.  
26  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Servers with separate iSCSI NIC and public NIC  
Corporate,  
public or private  
network  
iSCSI traffic  
DAS iSCSI  
and public LAN  
iSCSI traffic  
Management traffic  
SSR212PP2i  
EMC3313  
FIGURE 8.  
SSR212PP2i (Dual SP) Directly Connected to Two Servers  
Sample IP addresses  
Port  
IP address  
Subnet mask  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
Gateway  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
Storage Processor A iSCSI port 0  
iSCSI NIC/HBA 1  
172.31.1.150  
172.31.1.101  
172.31.1.151  
172.31.1.102  
172.31.2.150  
172.31.2.101  
172.31.2.152  
172.31.2.102  
Storage Processor A iSCSI port 1  
iSCSI NIC/HBA 1  
Storage Processor B iSCSI port 0  
iSCSI NIC/HBA 2  
Storage Processor B iSCSI port 1  
iSCSI NIC/HBA 2  
Management port IP addresses should match the corporate network scheme.  
Advantages  
You can easily migrate this low-cost storage for four servers to a switched  
environment.  
The dedicated iSCSI path ensures maximum throughput from host to storage system.  
The dedicated paths provide inherent security.  
Disadvantages  
Since only two servers can connect to the storage system, this configuration does not  
take full advantage of the SSR212PP2i s connectivity capabilities.  
SSR212PP2i Directly Connected to Four Servers  
Figure 9 shows four servers, each with an iSCSI initiator directly cabled to an  
SSR212PP2i iSCSI data port.  
Intel Storage System SSR212PP User Guide  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Servers with separate iSCSI NICs and public NIC  
Corporate,  
public or private  
network  
DAS iSCSI  
and public LAN  
iSCSI traffic  
iSCSI traffic  
Management Traffic  
SSR212PP2i  
(dual SP)  
EMC3315  
FIGURE 9.  
SSR212PP2i (Dual SP) Directly Connected to Four Servers  
Sample IP addresses  
Port  
IP address  
Subnet mask  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
Gateway  
Storage Processor A iSCSI port 0  
Server 1 iSCSI NIC/HBA 1  
Storage Processor A iSCSI port 1  
Server 2 iSCSI NIC/HBA 1  
Storage Processor B iSCSI port 0  
Server 3 iSCSI NIC/HBA 1  
Storage Processor B iSCSI port 1  
Server 4 iSCSI NIC/HBA 1  
172.31.1.150  
172.31.1.101  
172.31.2.150  
172.31.2.102  
172.31.3.150  
172.31.3.103  
172.31.4.150  
172.31.4.104  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
Management port IP addresses should match the corporate network scheme.  
Advantages  
You can easily migrate this low-cost storage for four servers to a switched  
environment.  
The dedicated iSCSI path ensures maximum throughput from host to storage system.  
Takes maximum advantage of the SSR212PP2i connectivity capabilities.  
The dedicated paths provide inherent security.  
Disadvantages  
Since there is only one path to the SSR212PP2i from each server, this configuration  
provides no failover or load balancing capabilities.  
SSR212PPi Connected to a Dedicated iSCSI Network (Single-Initiator  
Servers)  
Figure 10 shows an SSR212PPi with up to ten servers. Each server has a single iSCSI  
initiator, and is connected with a single Ethernet switch (dedicated for iSCSI traffic) to the  
storage system s iSCSI data ports.  
28  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Server with separate iSCSI NIC and public NIC  
Corporate,  
public or private  
network  
Dedicated  
iSCSI LAN  
Management Traffic  
iSCSI traffic  
SSR212PPi  
EMC3316  
FIGURE 10. SSR212PPi (Single SP) Connected to a Dedicated Network  
Sample IP addresses  
Port  
IP address  
Subnet mask  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
Gateway  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
Storage Processor A iSCSI port 0  
Storage Processor A iSCSI port 1  
Server 1 iSCSI NIC/HBA 1  
Server 2 iSCSI NIC/HBA 1  
Server 3 iSCSI NIC/HBA 3  
Continue for up to 10 servers . . .  
172.31.1.150  
172.31.1.151  
172.31.1.101  
172.31.1.102  
172.31.1.103  
Management port IP addresses should match the corporate network scheme.  
Advantages  
Low-cost storage for up to ten servers.  
Adding NICs or iSCSI HBAs to the configuration increases throughput.  
Connection to multiple servers maximizes use of the storage system s capabilities.  
A dedicated iSCSI LAN avoids network contention with your corporate LAN, and  
reduces security risks.  
Disadvantages  
No storage processor failover capability.  
SSR212PPi Connected to a Dedicated iSCSI Network (Multiple-  
Initiator Servers)  
Figure 11 shows an SSR212PPi with up to ten servers. Each server has two iSCSI  
initiators, and is connected with Ethernet switches (dedicated for iSCSI traffic) to the  
storage system s iSCSI data ports.  
Intel Storage System SSR212PP User Guide  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Servers with separate iSCSI NIC and public NIC  
Corporate,  
public or private  
network  
Management traffic  
iSCSI traffic  
SSR212PPi  
EMC3317  
FIGURE 11. SSR212PPi On a Dedicated LAN with Redundant Paths  
Sample IP addresses  
Port  
IP address  
Subnet mask  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
Gateway  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
Storage Processor A iSCSI port 0  
Storage Processor A iSCSI port 1  
Server 1 iSCSI NIC/HBA 1  
Server 1 iSCSI NIC/HBA 2  
Server 2 iSCSI NIC/HBA 1  
Server 2 iSCSI NIC/HBA 2  
Continue for up to 10 servers . . .  
172.31.1.150  
172.31.2.150  
172.31.1.101  
172.31.2.101  
172.31.1.102  
172.31.2.102  
For additional throughput, add NICs or iSCSI HBAs to the configuration.  
Management port IP addresses should match the corporate network scheme.  
Advantages  
Low-cost storage for up to ten servers.  
Connection to multiple servers maximizes the use of the storage system s capabilities.  
A dedicated iSCSI LAN avoids network contention with your corporate LAN, and  
reduces security risks.  
Connection to each SP port from both servers provides redundant data paths in case  
one path fails.  
Disadvantages  
No load balancing.  
SSR212PP2i Connected to a Dedicated iSCSI Network (Single-Initiator  
Servers)  
Figure 12 shows an SSR212PP2i with up to ten servers. Each server has a single iSCSI  
initiator, and is connected with a single Ethernet switch, dedicated for iSCSI traffic, to the  
storage system s four iSCSI data ports. This represents the most common SSR212PP2i  
configuration.  
30  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Server w/ separate iSCSI NIC & public NIC  
Corporate,  
Public or Private  
Network  
Dedicated  
iSCSI LAN  
iSCSI Traffic  
SSR212PP2i  
(dual SP)  
EMC3320  
FIGURE 12. Network-Connect SSR212PP2i (Dual SP, Dedicated LAN)  
Sample IP addresses  
Port  
IP address  
Subnet mask  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
Gateway  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
Storage Processor A iSCSI port 0  
Storage Processor A iSCSI port 1  
Storage Processor B iSCSI port 0  
Storage Processor B iSCSI port 1  
Server 1 iSCSI NIC/HBA 1  
Server 2 iSCSI NIC/HBA 1  
Server 3 iSCSI NIC/HBA 1  
Continue for up to 10 servers . . .  
172.31.1.150  
172.31.1.151  
172.31.1.152  
172.31.1.153  
172.31.1.101  
172.31.1.102  
172.31.1.103  
The above addresses are not valid for a Linux environment, in which each SP port  
must be on a different subnet. A Linux host in this configuration could log in to  
ports on SP A or SP B, but not both. Management port IP addresses should match  
the corporate network scheme.  
Advantages  
Low-cost storage for up to ten servers.  
Connection to multiple servers maximizes use of the storage system s capabilities.  
Using a dedicated iSCSI LAN avoids network contention with your corporate LAN  
and reduces security risks.  
This configuration provides failover capabilities in the event of a storage processor  
failure.  
Using two storage processors improves overall storage system performance.  
Disadvantages  
This configuration has limited failover capability since the single initiator and single  
switch provide only one path from a server to the iSCSI Ethernet switch.  
Intel Storage System SSR212PP User Guide  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SSR212PP2i Connected to a Dedicated iSCSI Network (Multiple-  
Initiator Servers)  
Figure 13 shows an SSR212PP2i with up to ten servers. Each server has two iSCSI  
initiators, and is connected with Ethernet switches (dedicated for iSCSI traffic) to the  
storage system s four iSCSI data ports. This represents a secure and highly available  
SSR212PP2i configuration.  
Server with 2 iSCSI NICs and 1 public NIC  
Corporate,  
public or private  
network  
iSCSI traffic  
iSCSI traffic  
Management traffic  
SSR212PP2i  
EMC3321  
FIGURE 13. SSR212PP2i On a Dedicated LAN with Redundant Paths  
Sample IP addresses  
Port  
IP address  
Subnet mask  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
Gateway  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
Storage Processor A iSCSI port 0  
Storage Processor A iSCSI port 1  
Storage Processor B iSCSI port 0  
Storage Processor B iSCSI port 1  
Server 1 iSCSI NIC/HBA 1  
Server 1 iSCSI NIC/HBA 2  
Server 2 iSCSI NIC/HBA 1  
Server 2 iSCSI NIC/HBA 2  
Server 3 iSCSI NIC/HBA 1  
Server 3 iSCSI NIC/HBA 2  
Continue for up to 10 servers . . .  
172.31.1.150  
172.31.2.150  
172.31.1.151  
172.31.2.151  
172.31.1.101  
172.31.2.101  
172.31.1.102  
172.31.2.102  
172.31.1.103  
172.31.2.103  
Management port IP addresses should match the corporate network scheme.  
Advantages  
Low-cost storage for up to ten servers.  
Connection to multiple servers maximizes the use of the storage system s capabilities.  
Using a dedicated iSCSI LAN avoids network contention with your corporate LAN  
and reduces security risks  
Failover capabilities in the event of a storage processor failure.  
32  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Using two storage processors improves overall storage system performance.  
Connection to each SP port from both servers provides redundant data paths in case  
one path fails.  
Disadvantages  
This configuration incurs the cost of a second switch.  
SSR212PPi Connected to a Dedicated iSCSI/Management Network  
(Single-Initiator Server)  
Figure 14 shows an SSR212PPi with up to ten servers. Each server has a single iSCSI  
initiator, and is connected with a single Ethernet switch (used for management and iSCSI  
traffic) to the storage system s iSCSI data and management ports.  
This configuration requires a NIC connection; iSCSI HBAs qualified on  
SSR212PP-Series systems do not support management input/output.  
Server with separate iSCSI NIC and public NIC  
Corporate,  
public or private  
Dedicated  
iSCSI LAN  
network  
iSCSI traffic  
SSR212PPi  
EMC3318  
FIGURE 14. SSR212PPi On a Dedicated LAN with Limited Access to Management  
Ports  
Sample IP addresses  
Port  
IP address  
Subnet mask  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
Gateway  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
Storage Processor A management port  
Storage Processor A iSCSI port 0  
Storage Processor A iSCSI port 1  
Server 1 iSCSI NIC/HBA 1  
Server 2 iSCSI NIC/HBA 1  
Server 3 iSCSI NIC/HBA 1  
Continue for up to 10 servers . . .  
172.31.1.200  
172.31.1.150  
172.31.1.151  
172.31.1.101  
172.31.1.102  
172.31.1.103  
Intel Storage System SSR212PP User Guide  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Management port IP addresses should match the corporate network scheme.  
Advantages  
Low-cost storage for up to ten servers.  
Improved security: System management requires a connection to the private network.  
Adding NICs to the configuration increases throughput.  
Connection to multiple servers maximizes use of the storage system s capabilities.  
A dedicated iSCSI LAN avoids network contention with your corporate LAN and  
reduces security risks.  
Disadvantages  
Limited failover capability since the single initiator and single switch provide only  
one path from a server to the iSCSI Ethernet switch.  
Reduced access for remote management: To perform management tasks, you must be  
connected to a host on the private network.  
One storage processor does not allow for failover in case of SP failure.  
SSR212PPi Connected to a Dedicated iSCSI/Management Network  
(Multiple-Initiator Servers)  
Figure 15 shows an SSR212PPi with up to ten servers. Each server has two iSCSI  
initiators, and is connected with Ethernet switches (used for management and iSCSI  
traffic) to the storage system s iSCSI data and management ports.  
This configuration requires a NIC connection; iSCSI HBAs qualified on  
SSR212PP-Series systems do not support management input/output.  
Servers with 2 iSCSI NICs and 1 public NIC  
Corporate,  
public or private  
network  
Management traffic  
iSCSI traffic  
iSCSI traffic  
SSR212PPi  
EMC3319  
FIGURE 15. SSR212PPi On a Dedicated LAN (Redundant Paths, Limited Access to  
Management Ports)  
34  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Sample IP addresses  
Port  
IP address  
Subnet mask  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
Gateway  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
Storage Processor A management port  
Storage Processor A iSCSI port 0  
Storage Processor A iSCSI port 1  
Server 1 iSCSI NIC/HBA 1  
Server 1 iSCSI NIC/HBA 2  
Server 2 iSCSI NIC/HBA 1  
Server 2 iSCSI NIC/HBA 2  
Continue for up to 10 servers . . .  
172.31.1.200  
172.31.1.150  
172.31.2.150  
172.31.1.101  
172.31.1.102  
172.31.2.101  
172.31.2.102  
Management port IP addresses should match the iSCSI LAN address scheme.  
Advantages  
Low-cost storage for up to ten servers.  
Improved security: System management requires a connection to the private network.  
Connection to multiple servers maximizes use of the storage system s capabilities.  
You can increase throughput by adding NICs to the configuration.  
Connection to each SP port from both switches provides redundant data paths in case  
one path fails.  
Disadvantages  
Reduced access for remote management: To perform management tasks, you must be  
connected to a host on the private network.  
One storage processor does not allow for failover in case of SP failure.  
SSR212PP2i Connected to a Dedicated iSCSI/Management Network  
(Single-Initiator Server)  
Figure 16 shows a variation of the previous SSR212PP2i configuration with up to ten  
servers on a dedicated LAN. Each server has a single iSCSI initiator, and is connected  
with a single Ethernet switch to the storage system s iSCSI data and management ports.  
Intel Storage System SSR212PP User Guide  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
This configuration requires a NIC connection; iSCSI HBAs qualified on  
SSR212PP-Series systems do not support management input/output.  
Server with separate iSCSI NIC and public NIC  
Corporate,  
public or private  
Dedicated  
iSCSI LAN  
network  
SSR212PP2i  
(dual SP)  
EMC3322  
FIGURE 16. SSR212PP2i (Dual SP) Connected to a Private LAN  
Sample IP addresses  
Port  
IP address  
Subnet mask  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
Gateway  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
Storage Processor A management port  
Storage Processor A iSCSI port 0  
Storage Processor A iSCSI port 1  
Storage Processor B management port  
Storage Processor B iSCSI port 0  
Storage Processor B iSCSI port 1  
Server 1 iSCSI NIC/HBA 1  
172.31.1.200  
172.31.1.150  
172.31.1.151  
172.31.1.201  
172.31.1.152  
172.31.1.153  
172.31.1.101  
172.31.1.102  
172.31.1.103  
Server 2 iSCSI NIC/HBA 1  
Server 3 iSCSI NIC/HBA 1  
Continue for up to 10 servers . . .  
The private network must be on a different subnet from the public LAN.  
Advantages  
Improved security: System management requires a connection to the private network.  
Simplified network setup: All of the storage system ports are on the private network,  
so you need to assign only one set of addresses on a single subnet. A network  
administrator aware of all available addresses must assign any addresses required for  
the public network from a smaller pool.  
Simplified troubleshooting: Since everything is on a dedicated private network, you  
have fewer variables to consider when issues arise.  
36  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Disadvantages  
Reduced access for remote management: To perform management tasks, you must be  
connected to a host on the private network.  
Limited failover capability since the single initiator and single switch provide only  
one path from a server to the iSCSI Ethernet switch.  
SSR212PP2i Connected to a Dedicated iSCSI Network (Multiple-  
Initiator Servers)  
Figure 17 shows an SSR212PP2i with up to ten servers. Each server has two iSCSI  
initiators connected with two Ethernet switches (dedicated for storage system traffic) to  
SSR212PP2i iSCSI data ports. The performance and availability advantages of this  
configuration make it optimal for many environments.  
This configuration requires a NIC connection; iSCSI HBAs qualified on  
SSR212PP-Series systems do not support management input/output.  
Servers with 2 iSCSI NICs and 1 public NIC  
Corporate,  
public or private  
network  
Management  
Mgmt  
traffic  
traffic  
iSCSI traffic  
iSCSI traffic  
iSCSI traffic  
SSR212PP2i  
(dual SP)  
EMC3323  
FIGURE 17. SSR212PP2i (Dual SP) On a Dedicated LAN with Redundant iSCSI  
Paths  
Intel Storage System SSR212PP User Guide  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Sample IP addresses  
Port  
IP address  
Subnet mask  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
255.255.255.0  
Gateway  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
0.0.0.0  
Storage Processor A management port  
Storage Processor A iSCSI port 0  
Storage Processor A iSCSI port 1  
Storage Processor B management port  
Storage Processor B iSCSI port 0  
Storage Processor B iSCSI port 1  
Server 1 iSCSI NIC/HBA 1  
172.31.1.200  
172.31.1.150  
172.31.2.150  
172.31.1.201  
172.31.1.151  
172.31.2.151  
172.31.1.101  
172.31.2.101  
172.31.1.102  
172.31.2.102  
172.31.1.103  
172.31.2.103  
Server 1 iSCSI NIC/HBA 2  
Server 2 iSCSI NIC/HBA 1  
Server 2 iSCSI NIC/HBA 2  
Server 3 iSCSI NIC/HBA 1  
Server 3 iSCSI NIC/HBA 2  
Continue for up to 10 servers . . .  
Advantages  
Low-cost storage for up to ten servers.  
Connection to multiple servers maximizes the use of the storage system s capabilities.  
The use of dedicated iSCSI LANs avoids network contention with your corporate  
LAN and reduces security risk.  
This configuration offers the best overall failover capabilities to withstand storage  
processor, switch, initiator, or cable failures.  
Using two storage processors improves overall storage system performance.  
Disadvantages  
Duplicate hardware raises configuration costs.  
Redundancy increases hardware configuration and setup complexity.  
Reduced access for remote management: To perform management tasks, you must be  
connected to a host on the private network.  
SSR212PP2i/SSR212PPi Connected to a Shared Public/iSCSI Network  
Figure 18 shows SSR212PP2i and SSR212PPi storage systems with up to ten servers.  
Each server has a single iSCSI NIC connected with an Ethernet switch (shared for both  
corporate LAN and iSCSI traffic) to the storage system s iSCSI data and management  
ports.  
38  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Single NIC sharing  
iSCSI and public  
LAN  
Corporate,  
public or private  
network  
Corporate,  
public or private  
network  
Management  
traffic  
Mgmt  
traffic  
Mgmt  
traffic  
iSCSI  
traffic  
Shared iSCSI LAN  
and public LAN  
iSCSI  
traffic  
iSCSI  
traffic  
SSR212PPi  
SSR212PP2i  
(dual SP)  
EMC3324  
FIGURE 18. SSR212PPi/SSR212PP2i (Single SP) to a Shared Single iSCSI NIC  
IP addresses in a shared environment should match the corporate network IP  
address scheme.  
Advantages  
Sharing a switch with your public LAN costs less than dedicating a switch for iSCSI  
traffic.  
Provides low-cost storage for up to ten servers  
SSR212PP2i provides failover capabilities in the event of a storage processor failure.  
SSR212PP2i has two storage processors and thus improves overall storage system  
performance.  
Disadvantages  
Possible contention between iSCSI traffic and LAN traffic on a shared Ethernet  
switch could reduce performance. The source of contention (iSCSI or LAN traffic) is  
also difficult to identify.  
Limited failover capability since the single initiator provides only one path from a  
server to the iSCSI Ethernet switch.  
All traffic on a single NIC reduces overall server performance.  
A shared LAN usually requires CHAP security.  
Intel Storage System SSR212PP User Guide  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Storage System Disk Information  
This section defines storage system disk information. Fill out the following worksheet as  
described in this section.  
Disk Information  
Disk Pool  
Virtual Disk  
Number  
(1- 6 or  
Spare)  
Disks to  
Form Pool Capacity  
(1-12)  
Free  
Capacity Space  
Function (Gbytes) (Gbytes) Assigned  
Server  
To Be  
(Gbytes) Name  
Use this worksheet to list the disk pools and virtual disks that you will create. A sample  
worksheet section and information about completing the columns in it follows. The  
sample worksheet shows that 20- and 38-Gbyte virtual disks have been reserved for  
expansion of virtual disks in the three disk pools. The storage system described in the  
worksheet has 250-Gbyte disks (not 500-Gbyte disks).  
Disk Information  
Disk Pool  
Virtual Disk  
Number Disks to  
Free  
Space  
(Gbytes)  
Server  
(1- 6 or  
Spare)  
Form Pool  
(1-12)  
Capacity  
(Gbytes) Name  
Capacity  
(Gbytes)  
To Be  
Function  
Assigned  
1
0, 1, 2, 3 651 Vdisk1 Users A-N  
315  
20  
PC1234  
Vdisk2 Users O-Z 316  
2
3
4, 5, 6, 7 690 Vdisk3 Database  
660  
440  
38  
20  
8, 9, 10  
11  
460 Vdisk4  
Mail  
Spare  
40  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Number (1-6 or spare)  
You must create at least one disk pool for virtual disks. You can create up to four RAID 5  
disk pools or six RAID 1/0 disk pools, numbered 1-6, in a storage system.  
If your system has two SPs, you should create at least two disk pools, since the software  
assigns one or more disk pools to each SP; that is, it assigns disk pool 1 and all its virtual  
disks to SP A, disk pool 2 and all its disks to SP B, disk pool 3 and its disks to SP A, and  
disk pool 4 and its disks to SP B. If you create only one pool, all virtual disks in the  
storage system will be assigned to SP A.  
Disks to Form Each Pool  
For each pool, specify the numbers of the disks you will include. The number of disks in a  
pool determines its capacity. Generally, we suggest no more than six; the minimum is  
three for RAID 5 and two for RAID 1/0 pools.  
For maximum use of space on the disks, it is recommended that you do not combine disks  
0 through 3 (the operating system disks) in a disk pool with other disks. Part of the space  
on the operating system disks is preloaded with system data, and as a result, is not  
available for your data. If you combine operating system disks in a disk pool with other  
disks, each of the other disks loses space for data equal to the system data space on an  
operating system disk.  
If you have disks of differing capacities (for example, 250- and 500-Gbyte), always use  
disks of the same capacity when creating a disk pool. If the disks have different capacities,  
the software will format each disk at the smaller of the two disk sizes, wasting more than  
200 Gbytes of potential storage on each larger disk.  
When you create disk pools, consider making one disk a hot spare. A hot spare allows  
your system to continue running with its normal performance and retain its redundancy if  
a disk fails. However, because a hot spare is reserved as a replacement disk, it cannot be  
used as a virtual disk. You may not want to devote an entire disk to maintaining  
redundancy after a disk failure.  
If you create disk pools that use all the storage system disks, no space will remain for a hot  
spare. Later, if you need to create a hot spare, you must delete all the virtual disks in the  
disk pool, delete the pool, create a new pool, and then create the hot spare and new virtual  
disks on the new pool.  
Always use a disk with the largest capacity as a hot spare. You can make any disk other  
than 0, 1, 2, or 3 a hot spare. If you decide to use a hot spare, write "Spare" in the  
appropriate row in column 1 and the disk number in column 2.  
If you want to create disk snapshots, that is, capture point-in-time images of a virtual disk,  
then you must reserve disk space for snapshot disk resources. The snapshot resource uses  
this space transparently for snapshot operations, but the space must be available and not  
allocated to any virtual disk. The snapshot resource requires a maximum of 20 percent of  
each virtual disk whose point-in-time images you will capture, allocated in 10-Gbyte  
blocks. For example, if you will take snapshots of a 290-Gbyte virtual disk, leave 60  
Gbytes of disk space unused. Twenty percent of 290 is 58, but space is given in 10-Gbyte  
blocks; therefore you must reserve 60 Gbytes.  
From Disk 0 through Disk 11, select the disks that you want to include in the disk pool,  
and select a disk to be a Hot Spare. Record this information in the Storage System disk  
information worksheet.  
Intel Storage System SSR212PP User Guide  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disk pool capacity (Gbytes)  
To calculate the size of a RAID 5 disk pool, multiply the number of disks less 1 (n-1) by  
the disk capacity. For a RAID 1/0 disk pool, multiply the number of disks by the disk  
capacity, then divide by 2. The following table shows the formatted capacity of  
SSR212PP-Series disks.  
250 Gbyte Disks  
500 Gbyte disks  
217 Gbytes per disk  
230 Gbytes per disk  
458 Gbytes per disk  
445 Gbytes per disk  
Disks 0-3  
Disks 4-11  
Name  
Name the virtual disks in each disk pool. You can include up to 128 virtual disks in a disk  
pool. The default virtual disk name is Virtual Disk n, where n is the sequential number,  
starting with 1. However, you can substitute a more meaningful name, such as Users or  
Mail. You can choose to have multiple applications on the same virtual disk.  
If you will have more than one disk pool, try to place the same number of virtual disks in  
each pool. Or, if you know that one or more virtual disks will be accessed often, you might  
choose to place these on their own SP. For example, you might place a heavily accessed  
virtual disk, such as a database, by itself on disk pool 2, attached to SP B; and place other,  
lightly accessed virtual disks in disk pool 1, attached to SP A.  
Function  
Describe the purpose of the virtual disk.  
Virtual disk capacity (Gbytes)  
Determine the capacity of each virtual disk in the disk pool. The combined capacity of all  
virtual disks cannot exceed the available space of the parent disk pool.  
Decide how much space in the disk pool should be free space. Generally, you should leave  
a modest amount of free space, such as 10 percent of the disk pool size, in each pool. Then  
you can expand any of the virtual disks in the pool up to the amount of reserved space.  
Free space (Gbytes)  
Enter the amount of free space you want to reserve for expansion. Note this space is  
available to all virtual disks in the disk pool; that is, if there are multiple virtual disks in  
the pool, you can allocate part or all of the free space to one virtual disk or among several  
disks.  
If you do not reserve adequate free space in a disk pool, and you need more space  
on a virtual disk in the pool, you must back up the data in the pool, destroy the pool,  
create a new pool with a larger virtual disk, and then reload the data.  
Server to be assigned (assigned servers)  
You will need to specify each assigned server when you create the virtual disk. Write the  
server hostname here. The maximum number of servers you can connect to one storage  
system is ten.  
42  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
What is Microsoft iSNS?  
Microsoft Internet Storage Naming Service (iSNS) is an option that applies to  
configurations with multiple hosts.  
The iSNS service provides automated discovery, management and configuration of iSCSI  
devices. It eliminates the need to manually configure each individual storage device with  
its own list of initiators and targets. Once configured, the iSNS server assumes  
responsibility for the discovery and management of iSCSI devices.  
The iSNS service includes an iSNS server component and iSNS client components. The  
iSNS server must reside somewhere within the IP storage network, for example, in the  
switch firmware, or on a host. An iSNS client resides on both the SSR212PP-Series iSCSI  
storage system and any iSCSI hosts connected to the storage system. When you start the  
storage system, the iSNS client on the storage system gathers all the storage system s  
iSCSI port information and stores it locally on the storage system. When you add a server  
to the storage system s iSNS configuration, Navisphere Express establishes a connection  
from the storage system to the iSNS server, and then registers all the stored information on  
the storage system with the iSNS server.  
To use the features of the iSNS service in an iSCSI storage environment:  
An iSNS server must be running on a network to which the storage system has access.  
The NIC or iSCSI HBA initiators must be able to use the iSNS service.  
The iSNS server must be able to communicate with the storage system.  
Figure 19 represents a sample iSNS configuration. In this configuration, the management  
and storage networks are separate. The management station is used to configure both the  
iSNS servers and the storage system (using Navisphere Express). The iSNS servers are  
also connected to the storage network so that the clients may query them for target  
information. The storage system uses either the storage or the management network to  
register its targets (ports) with the iSNS servers.  
Intel Storage System SSR212PP User Guide  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Management  
station  
Management network  
iSNS  
Target  
queries  
registration  
Primary  
iSNS  
Clients  
(initiators)  
Backup  
iSNS  
server  
server  
SSR212PPi  
Target  
registration  
EMC3165  
Storage networks  
FIGURE 19. Sample iSNS Storage Conguration  
The storage system actively communicates with only one iSNS server at a time (the  
primary server). You can add additional servers to act as backup (secondary) servers.  
44  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
iSNS Server Worksheet  
Enter the public IP address and name of your network s primary iSNS server and  
secondary (backup) iSNS server if you have one.  
Note that the public IP address is not related to the server s iSCSI port addresses.  
TABLE 1.  
iSNS Server Worksheet  
Server type  
IP address  
Server name  
Primary iSNS server  
Secondary iSNS server  
Intel Storage System SSR212PP User Guide  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
What is CHAP?  
Challenge Handshake Authentication Protocol (CHAP) is an optional iSCSI  
authentication method where the target authenticates iSCSI initiators. CHAP consists of  
initiator CHAP and mutual CHAP, depending on which way the authentication occurs. For  
initiator CHAP, the target authenticates the initiator. Mutual CHAP can be configured in  
addition to initiator CHAP. For mutual CHAP, the initiator authenticates the target.  
Initiator CHAP  
To establish a connection and gain access to storage in an initiator CHAP configuration,  
the initiator must present a username and secret to the iSCSI target. The storage system  
compares the username and secret with a database of CHAP user accounts to authenticate  
the initiator.  
To set up initiator CHAP authentication, you enter the username and secret on the target,  
then configure each initiator to use that username and secret.  
Mutual CHAP  
In a mutual CHAP configuration, both the target and the initiator authenticate each other.  
In addition to setting up initiator CHAP, you can configure the initiator with a username  
and secret that the target must present to establish a connection. You must also configure  
the target to present this username and secret to initiators.  
If you are planning to set up optional CHAP authentication security on the storage system,  
prepare the following storage system CHAP security worksheets for initiator CHAP and  
mutual CHAP.  
46  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
iSCSI CHAP Authentication Worksheets  
If the storage system is on a private LAN, you can elect not to configure CHAP  
authentication. If the storage system is on a public LAN, we strongly recommend that you  
set CHAP security. If you do not set CHAP security for the storage system, any host  
connected to the LAN can read from and write to the storage system.  
CAUTION  
Whenever you record any security information such as the CHAP usernames and  
secrets (passwords), it is imperative that you store the data in a secure location.  
Storage System CHAP Levels  
To set up a basic CHAP level, you can add one or more usernames and corresponding  
secrets. Any initiator configured with one of these usernames/secrets can establish a  
connection.  
To set up an advanced CHAP level, you can configure both initiator CHAP and mutual  
CHAP. You can create initiator CHAP so that all initiators can use each username/secret  
(as in basic CHAP). You can also use the iSCSI node name (IQN) to create  
usernames/secrets that are restricted for use by a single initiator. Optionally, you can  
configure mutual CHAP with a single target CHAP username/secret.  
Initiator CHAP Worksheet  
If you want the storage system to authenticate initiators, fill out the Initiator CHAP  
Worksheet for all initiator accounts. Initiator CHAP must be set up and enabled for iSCSI  
security to work. The easiest way to configure initiator CHAP is to create a friendly  
username and secret for all initiators.  
Initiator name: ___________________________________________________________  
Use initiator name as system CHAP username:Yes___ No___  
Allow any initiator to log In with this username and secret:Yes___ No___  
CHAP username: _________________________________________________________  
CHAP secret: ________________________________ Specied in hex:Yes___ No___  
Initiator name: ___________________________________________________________  
Use initiator name as system CHAP username:Yes___ No___  
Allow any initiator to log In with this username and secret:Yes___ No___  
CHAP username: _________________________________________________________  
CHAP secret: ________________________________ Specied in hex:Yes___ No___  
Initiator name: ___________________________________________________________  
Use initiator name as system CHAP username:Yes___ No___  
Allow any initiator to log In with this username and secret:Yes___ No___  
CHAP username: _________________________________________________________  
CHAP secret: ________________________________ Specied in hex:Yes___ No___  
Intel Storage System SSR212PP User Guide  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Initiator name: ___________________________________________________________  
Use initiator name as system CHAP username:Yes___ No___  
Allow any initiator to log In with this username and secret:Yes___ No___  
CHAP username: _________________________________________________________  
CHAP secret: ________________________________ Specied in hex:Yes___ No___  
Initiator name: ___________________________________________________________  
Use initiator name as system CHAP username:Yes___ No___  
Allow any initiator to log In with this username and secret:Yes___ No___  
CHAP username: _________________________________________________________  
CHAP secret: ________________________________ Specied in hex:Yes___ No___  
Initiator name: ___________________________________________________________  
Use initiator name as system CHAP username:Yes___ No___  
Allow any initiator to log In with this username and secret:Yes___ No___  
CHAP username: _________________________________________________________  
CHAP secret: ________________________________ Specied in hex:Yes___ No___  
Initiator name: ___________________________________________________________  
Use initiator name as system CHAP username:Yes___ No___  
Allow any initiator to log In with this username and secret:Yes___ No___  
CHAP username: _________________________________________________________  
CHAP secret: ________________________________ Specied in hex:Yes___ No___  
Initiator name: ___________________________________________________________  
Use initiator name as system CHAP username:Yes___ No___  
Allow any initiator to log In with this username and secret:Yes___ No___  
CHAP username: _________________________________________________________  
CHAP secret: ________________________________ Specied in hex:Yes___ No___  
Initiator name  
The initiator name is a predefined name that usually begins with iqn (for iSCSI Qualified  
Name). You can determine the name by running the SANSurfer utility (shipped with  
QLogic HBAs) or the Microsoft iSCSI Software Initiator for Ethernet NICs. The  
Microsoft iSCSI Software Initiator is available on the Microsoft website.  
Use initiator name as system CHAP username  
If you want to use the initiator name as the CHAP username, check the Use Initiator Name  
as System CHAP Username box. If you want to create a new username, leave the box blank.  
CHAP username  
The CHAP username is a name that you assign for one user or for all users that connect to  
the storage system iSCSI port. Either you can use the same name as the initiator name or  
you can create a new name. If you use the same name as the initiator name, you are  
guaranteed to have a unique name. If you create a new friendly username, that name might  
not be unique unless you are on a private network and create a unique name for the  
network.  
48  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAP secret (password)  
For ASCII, the valid range is 12 to 16 printable characters. For hexadecimal (hex), the  
valid range is 24 to 32 hexadecimal characters, displayed in pairs. If you want to specify in  
hex, mark the box.  
Allow any initiator to log In with this username and secret  
To allow any initiator to log in to the storage system, check the Allow any Initiator to Login  
with this Username and Secret box. If all initiators are trusted (for example, in a department  
or organization), you might want to check this for convenience. You can always grant or  
restrict initiator access to this storage system through the virtual disks.  
Mutual CHAP Worksheet  
Mutual CHAP management provides an optional extra level of security that lets initiators  
verify the identity of the target storage system. If you want the initiators to authenticate  
targets, fill out the Mutual CHAP worksheet for all mutual CHAP accounts.  
Target CHAP username: _________________________________________________  
Target CHAP secret (password): _______________________ Specied in hex:Yes ___ No ___  
CAUTION  
Whenever you record any security information such as the CHAP usernames and  
secrets (passwords), it is imperative that you store the data in a secure location.  
Intel Storage System SSR212PP User Guide  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
50  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing an iSCSI  
Storage System  
4
This procedure describes the process of connecting an SSR212PP-Series iSCSI (Internet  
SCSI) storage system (SSR212PPi or SSR212PP2i) to a Microsoft Windows¤ or Linux  
server in one of these methods:  
through the network.  
directly.  
Terminology  
host  
A computer that is or will be connected to an SSR212PP-Series storage  
system. This computer is called either a management host or a server,  
depending on how it is or will be connected to the storage system.  
management host  
A host from which you manage SSR212PP-Series storage systems. It  
must be on the same LAN as the storage system management ports. A  
management host may also be a server.  
server  
A host that is already or will be connected directly to the Fibre Channel  
ports on an SSR212PP-Series storage system. A management host may  
also be a server.  
existing server The server that is already configured for and connected to an SSR212PP-  
Series storage system.  
new server  
A server that is not already connected to or set up for an SSR212PP-  
Series storage system.  
existing NIC or iSCSI HBA  
The network interface card (NIC) or iSCSI host bus adapter (HBA) that is  
already installed in a server.  
new NIC or iSCSI HBA  
The NIC or iSCSI HBA that was not already installed in the server.  
existing storage system  
An SSR212PP-Series storage system that is already connected to a server  
and configured for storage.  
new storage system  
A storage system that is not connected to a server or configured for  
storage. It is just as it was shipped to you.  
Intel Storage System SSR212PP User Guide  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
eld-replaceable unit (FRU)  
A storage system component that you can add to your storage system or  
replace in your storage system at your site. Examples of FRUs are disks,  
power supplies, memory cards, and power supplies.  
storage processor (SP)  
A printed-circuit board with processors, memory modules, and control  
logic that manages the I/O between the server and the disk modules.  
disk pool  
A set of disks with the same capacity and RAID type on which you create  
one of more virtual disks.  
virtual disk  
A grouping of physical disk partitions into one span of disk storage space.  
Each virtual disk you create is distributed equally across the disks in the  
disk pool. A virtual disk looks like an individual disk to the server s  
operating system.  
CHAP  
iSNS  
Challenge Handshake Authentication Protocol. An optional security  
mechanism to control access to an iSCSI storage system over the iSCSI  
data ports.  
Microsoft Internet Storage Naming Service (iSNS) provides automated  
discovery, management and configuration of iSCSI devices.  
An SSR212PPi storage system has one SP, so it is called a single-SP system. An  
SSR212PP2i storage system has two SPs, so it is called a dual-SP system.  
BeforeYou Start  
Review Tested Hardware and OS List (THOL) on the SSR212PP support website to  
confirm that the following are supported:  
The server hardware that will access the storage system.  
The operating system version running on the server hardware.  
For a new storage system installation, you will need:  
An SSR212PPi or SSR212PP2i storage system and the cables, rails, and CDs that ship  
with it.  
For an SSR212PP2i (dual-SP system), an uninterruptible power supply (UPS) kit,  
including the power cords, UPS serial cable, and mounting hardware.  
Standard AC power for each power supply in the storage system from an independent  
AC source or a cabinet/rack power distribution unit.  
A CAT 5, CAT 5e, or CAT 6 network cable for each management port you will use on  
the storage system.  
The following management port network information, which the person responsible  
for your network should provide:  
52  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Static IP address for each SP in the storage system.  
Subnet mask for the LAN to which you will connect the storage system.  
Default gateway for the LAN to which you will connect the storage system.  
For any installation, you will need:  
A management host with a supported Internet browser for running Navisphere¤  
Express and on the same network as the storage system management ports. This host  
can also be the server. For supported hosts and browsers, refer to Tested Hardware  
and OS List (THOL) on the SSR212PP support website.  
A Linux or Windows host that is or will be a server with Fibre Channel connections to  
the storage system. This server must have all required updates, such as hot fixes or  
patches, installed. For supported hosts and required updates, refer to Tested Hardware  
and OS List (THOL) on the SSR212PP support website.  
Two separate network subnets: one for the storage-system iSCSI ports and one for the  
management ports. The storage-system iSCSI ports must connect to an Ethernet NIC  
or iSCSI HBA. The storage-system management ports can connect to either a 10/100  
or 1-gigabit Ethernet LAN. A 1-gigabit Ethernet LAN is recommended for best  
performance.  
The following cables, which may already be connected for a configuration with an  
existing storage system or server:  
A CAT 5, CAT 5e, or CAT 6 network cable (100 meters maximum) for each iSCSI  
port that you will use on the storage system. It is recommended to use CAT 6  
cables for best performance.  
Network cables as needed for the hosts.  
A method for writing data to a virtual disk on the storage system to test the path from  
a new HBA to the storage system.  
Intel Storage System SSR212PP User Guide  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Installation Procedure  
STEP 1. Install the NICs or iSCSI HBAs in the server. See Procedure 7, "Installing NICs or iSCSI  
HBAs in the Server," on page 63.  
STEP 2. Install PowerPath on the server.  
If the server is running Windows 2003 Server, ypu must install PowerPath iSCI using  
install the fully-featured PowerPath application. (PowerPath for iSCSI does not  
provide I/O load balancing).  
STEP 3. Install the Navisphere Server Utility. See Procedure 9, "Installing the Navisphere Server  
STEP 4. If you have an SSR212PP2i system, install the UPS:  
CAUTION  
You must install the UPS that shipped with your storage system. You cannot use  
any other type of UPS.  
a. Unpack the UPS and save the packaging. Verify that the cables and mounting kit were  
included.  
b. Install the UPS in a 19-inch NEMA-standard cabinet/rack, as described in the  
documentation provided with the UPS.  
CAUTION  
The UPS ships with the battery cable disconnected. Be sure to connect this cable  
firmly when you install the UPS. If this cable is not securely connected, the  
Replace Battery light turns on.  
STEP 7. If you received a second power supply for your single-SP storage system, follow  
54  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
You may receive a second power supply that looks slightly different from the  
original, and/or different from the illustrations in this note. The two versions are  
functionally the same.  
STEP 8. If you received disks modules that are not already installed in the storage system, follow  
STEP 9. Connect the storage system to AC power.  
page 91 when installing an SSR212PPf (single-SP) storage system.  
when installing an SSR212PP2f (dual-SP) storage system.  
connect the management ports.  
STEP 11. Install the Navisphere Storage System Initialization Utility. See Procedure 17, "Installing  
STEP 12. Verify that the storage system is powered up completely:  
a. The Fault lights on each SP must be off and the Power light must be on. These lights  
are on the rear of the storage system (Figure 20 or Figure 21).  
Power Supply A Fault LED  
Power Supply A On  
Power LED  
Power On/Off Button SP A Boot/Fault LED  
EMC3285  
FIGURE 20. SSR212PPi Storage System Rear Lights (LEDs)  
Intel Storage System SSR212PP User Guide  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Power Supply B Fault LED  
PS B On  
Power Supply A Fault LED  
PS A On  
SP B Boot/Fault LED  
Power LED  
Power On/Off Button  
SP A Boot/Fault LED  
EMC3272  
FIGURE 21. SSR212PPi Storage System Rear Lights (LEDs)  
b. The amber system Fault light visible from the front of the storage system must be off  
(Figure 22).  
Fault  
Power  
Disk Activity  
SAB2934  
Lock  
FIGURE 22. Storage System Front Lights (LEDs)  
STEP 13. Run the Navisphere Storage System Initialization Utility. See Procedure 19, "Running  
the Server," on page 117 to connect to the server.  
STEP 16. Configure the storage system.  
To configure an existing storage system (one that was already connected to a server  
STEP 17. For networked configurations utlilizing iSCSI NICs, configure CHAP security to  
56  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
58  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Handling Field-Replaceable  
Units (FRU)  
5
This section describes the precautions that you must take and the general procedures you  
must follow when removing, installing, and storing disk modules, fans, memory cards,  
battery-backed cache cards, the storage processor assembly, or any other field replaceable  
unit (FRU).  
Power issues and FRUs  
SSR212PP-Series storage systems are designed to be powered up continually. Disks and  
power supplies are hot repairable; that is, you can replace faulty units while the system is  
running. Front bezels should always be attached and each compartment should contain a  
FRU or filler panel to ensure EMI compliance and proper air flow over the FRUs.  
You should not remove a faulty FRU until you have a replacement available.  
When you replace or install FRUs, you can inadvertently damage the sensitive electronic  
circuits in the equipment by simply touching them. Electrostatic charge that has  
accumulated on your body discharges through the circuits. If the air in the work area is  
very dry, running a humidifier in the work area will help decrease the risk of ESD damage.  
Follow the procedures below to prevent damage to the equipment.  
Read and understand the following instructions:  
Provide enough room to work on the equipment. Clear the work site of any  
unnecessary materials or materials that naturally build up electrostatic charge, such as  
foam packaging, foam cups, cellophane wrappers, and similar items.  
Do not remove replacement or upgrade FRUs from their antistatic packaging until you  
are ready to install them.  
Before you service a storage system, gather together the ESD kit and all other  
materials you will need. Once servicing begins, avoid moving away from the work  
site; otherwise, you may build up an electrostatic charge.  
An ESD wristband is supplied with your storage system. To use it, attach the clip of  
the ESD wristband (strap) to any bare (unpainted) metal on the storage system; then  
put the wristband around your wrist with the metal button against your skin.  
Use the ESD kit when handling any FRU. If an ESD kit is not available, follow the  
procedures in the "Without an ESD Kit" section.  
Intel Storage System SSR212PP User Guide  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Without an ESD Kit  
When an ESD kit is not available, use the following procedures to reduce the possibility of  
an electrostatic discharge by ensuring that your body and the subassembly are at the same  
electrostatic potential.  
These procedures are not a substitute for the use of an ESD kit. Follow them only when an  
ESD kit is not available.  
Before touching any FRU, touch a bare (unpainted) metal surface of the cabinet or  
storage system.  
Before removing any FRU from its antistatic bag, place one hand firmly on a bare  
metal surface of the storage system, and at the same time, pick up the FRU while it is  
still sealed in the antistatic bag. Once you have done this, do not move around the  
room or touch other furnishings, personnel, or surfaces until you have installed the  
FRU.  
When you remove a FRU from the antistatic bag, avoid touching any electronic  
components and circuits on it.  
If you must move around the room or touch other surfaces before installing a FRU,  
first place the FRU back in the antistatic bag. When you are ready again to install the  
FRU, repeat these procedures.  
60  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing HBAs in the  
Server  
6
For the server to communicate with the storage system Fibre Channel ports, the server  
must have one or more supported host bus adapters (HBAs).  
BeforeYou Start  
To complete this procedure, you need one or more supported HBAs with the latest  
supported BIOS and driver. For information on supported HBAs, BIOS, and drivers, refer  
to Tested Hardware and OS List (THOL) on the SSR212PP support website.  
Never mix HBAs from different vendors in the same server.  
CAUTION  
HBAs are very susceptible to damage caused by static discharge and need to be  
handled accordingly. Before handling HBAs, observe the following precautions:  
Store HBAs in anti-static bags.  
Use a ground (ESD) strap whenever you handle HBAs.  
Never plug or unplug HBAs with the power on. Severe component damage  
can result.  
STEP 1. If the server is powered up:  
a. Shut down the server s operating system.  
b. Power down the server.  
c. Unplug the server s power cord from the power outlet.  
STEP 2. Put on an ESD wristband, and clip its lead to bare metal on the server s chassis.  
STEP 3. For each HBA that you are installing:  
a. Locate an empty PCI bus slot.  
b. Install the HBA following the instructions provided by the vendor.  
STEP 4. Plug the server s power cord into the power outlet, and power up the server.  
Intel Storage System SSR212PP User Guide  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing or Updating the HBA Driver  
The server must run a supported HBA driver and that you install the latest supported  
version of the driver. For information on the supported HBA drivers, refer to Tested  
Hardware and OS List (THOL) on the SSR212PP support website.  
BeforeYou Start  
To complete this procedure, you will need:  
The latest version of the supported HBA driver. You can download the latest supported  
version and instructions for installing the HBA driver from the vendor s website. The  
HBA vendor websites are  
Emulex website  
http://www.emulex.com/ts/docoem/framemc.htm  
QLogic website  
On this site, select EMC in the "OEM-approved Drivers/Firmware" list at the bottom of  
the page.  
The HBA driver is also on the installation CD that ships with the HBA. This  
version may not be the latest supported version.  
Any updates, such as hot fixes or service packs to the server s operating system that are  
required for the HBA driver version you will install.  
For information on any required updates, refer to one of the following:  
Tested Hardware and OS List (THOL) on the SSR212PP support website.  
The HBA vendor s website.  
Installing the HBA Driver  
STEP 1. Install any updates, such as hot fixes or service packs, to the server s operating system that  
are required for the HBA driver version you are installing.  
STEP 2. After installing any updates, reboot the server.  
STEP 3. Install the driver following the instructions on the HBA vendor s website.  
STEP 4. Reboot the server when the installation program prompts you to reboot.  
STEP 5. If the installation program did not prompt you to reboot, then reboot the server when the  
driver installation is complete.  
62  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing PowerPath  
on the Server  
7
PowerPath manages the I/O paths between the server and storage system. PowerPath also  
provides I/O load balancing.  
You must install PowerPath¤ on each server that you will connect to the storage system.  
Installing PowerPath on a Windows Server  
For information on integrating PowerPath into an existing MSCS cluster, refer to the  
PowerPath for Windows Installation and Administrator s Guide in the "Technical  
documents" section on the SSR212PP support website.  
STEP 1. Insert the PowerPath installation CD in the server s CD drive.  
STEP 2. If autoplay is enabled on your server, start the installation as follows:  
a. When the Getting Started page appears, click the appropriate link in the Installation  
section for the server s operating system.  
b. Select Run this program from its current location (or similar message depending on  
your browser) and click OK.  
You can install the software from the Installation section by clicking the appropriate  
link for your operating system.  
STEP 3. If autoplay is not enabled on the server, start the installation as follows:  
a. On the Windows taskbar, select StartRun.  
b. In the Run window, enter the name of the appropriate installation program below, and  
click OK.  
For Windows 2000: d:\2000\EMCPP.W2000.x.y.z.GA.exe  
For 32-bit Windows Server 2003: d:\2003\EMCPP.W2003_32. x.y.z.GA.exe  
For 64-bit Windows Server 2003: d:\2003\EMCPP.W2003.64.x.y.z.GA.exe  
where d is the CD drive letter and x.y.z is the revision of PowerPath on the CD.  
If you do not know whether your Windows 2003 Server is 32-bit or 64-bit, right-click  
on My Computer and select Manage. Select System InformationSystem Summary.  
View the System Type option. If x86 displays, you have a 32 bit system. If IA64  
displays, you have a 64 bit system.  
Alternatively, double-click the platform-specific .exe icon in the appropriate directory  
on the CD.  
Intel Storage System SSR212PP User Guide  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
STEP 4. In the Choose Language Setup window, select the language you want for this installation  
and click OK.  
PowerPath installer is available in Brazilian Portuguese, English, French, German, Italian,  
Korean, Japanese, Latin American Spanish, and simplified Chinese.  
STEP 5. In the setup wizard Welcome window, click Next.  
STEP 6. In the SSR212PP-Series window, select Yes and click Next.  
STEP 7. Enter your name and organization and click Next.  
STEP 8. In the Custom Setup dialog box, select Next (you cannot connect any third-party storage  
systems to the server).  
CAUTION  
If you want to specify another directory, do not specify the Windows System  
directory for your system (specified by the %SYSTEMROOT% environmental  
variable). PowerPath will not function correctly if it is installed in this directory.  
STEP 9. In the Ready to Install the Program dialog box, click Install.  
STEP 10. In the InstallShield Wizard Completed dialog box, click Finish.  
STEP 11. When the setup wizard asks whether you want to reboot the host, click Yes.  
When PowerPath is installed, the following PowerPath Administrator icon appears on the  
Windows taskbar:  
Installing a PowerPath Patch  
Check the PowerPath part of the Register to download software section on the SSR212PP  
support website for a patch to the version of PowerPath that you just installed. If such a  
patch is available, install it, as described in the readme file that accompanies the patch.  
Installing PowerPath on a Linux Server  
If PowerPath is already running on the server, check the "Register to download software"  
section on the SSR212PP support website for a more recent version of PowerPath or a  
patch to the version of PowerPath installed on the server, and install it instead. If the server  
is running the most recent version and a patch exists for this version, install it, as described  
in the readme file that accompanies the patch.  
STEP 1. Save your Linux kernel and back up your system.  
STEP 2. Change the Linux kernel:  
a. If you load the HBA driver as a module, install its binary file in the appropriate  
location:  
i. If you are using Red Hat Linux:  
64  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
/lib/modules/‘uname -r‘/drivers/addon/hbaDriver  
where uname -r is the string returned to the console by the uname -r command  
and hbaDriver is the name of the HBA driver module  
ii. If you are using SuSE Linux:  
/lib/modules/‘uname -r‘/drivers/scsi  
where uname -r is the string returned to the console by the uname -r command  
If you have Red Hat Linux 3.0 SuSE Linux SLES 8 SP3 or higher, you no  
longer need to build the HBA driver modules and copy them to the above  
location. The pre-built kernel now includes these modules.  
b. Save your kernel change.  
STEP 3. Change the Linux configuration files.  
a. If you are using Red Hat Linux:  
i. Edit the /etc/modules.conf file to add an alias for each HBA.  
In the sample file below, the second and third lines are aliases for HBAs;  
driverModule in these entries is the name of the HBA driver module.  
alias eth0 eepro100  
alias scsi_hostadapter1 driverModule  
alias scsi_hostadapter2 driverModule  
ii. Enable the following parameters in /etc/modules.conf:  
max_scsi_luns  
scsi_allow_ghost_devices  
You must enable the last parameter so that you do not have to recompile the  
kernel to properly connect a Linux server to the storage system.  
For example, in the following modules.conf file, the max_scsi_luns and  
scsi_allow_ghost_devices parameters are enabled:  
alias parport_lowlevel parport_pc  
alias scsi_hostadapter1 driverModule  
alias scsi_hostadapter2 driverModule  
alias eth0 tla  
options scsi_mod max_scsi_luns=256 scsi_allow_ghost_devices=1  
where driverModule is the name of the HBA driver module for accessing the  
storage system.  
iii. Edit the /etc/modprobe.conf file as follows:  
^
For QLogic HBAs, make sure that the ql2xfailover and the CongRequired  
parameters are set to 0:  
options qla2xxx q12xfailover=0 CongRequired=0  
The variables x and xxx vary with the HBA model.  
^
For Emulex HBAs, set the value of the lpfc_nodev_tmo parameter to 10:  
options lpfc lpfc_nodev_tmo=10  
Intel Storage System SSR212PP User Guide  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iv. Run ls -l /boot and look at the line with initrd ->to determine which initrd file is  
used.  
v. Run uname -r to display the kernel version.  
vi. Enter:  
/sbin/mkinitrd -f -v initrd kernel  
where initrd is the configuration identified by ls -l /boot and kernel is the kernel  
version displayed by uname -r  
b. If you are using SuSE Linux  
i. Verify that the HBA driver is always loaded after the internal SCSI adapter driver  
as specified by the /etc/syscong/kernel file. For example, in the following file,  
driverModule (the HBA driver module for accessing the storage system) is always  
loaded after all internal SCSI drivers are loaded:  
INTINRD_MODULES="scsi_mod sd_mod cciss reiserfs driverModule"  
When loading HBA drivers into the ramdisk, make sure that the HBA module  
name used in /etc/syscong/kernel is the same as that used in the /etc/modules.conf  
file.  
ii. Enable the following parameters in /etc/modules.conf:  
max_scsi_luns  
scsi_allow_ghost_devices  
You must enable the last parameter so that you do not have to recompile the  
kernel to properly connect a Linux host to the storage system.  
For example, in the following modules.conf file, the max_scsi_luns and  
scsi_allow_ghost_devices parameters are enabled:  
alias parport_lowlevel parport_pc  
alias scsi_hostadapter1 driverModule  
alias scsi_hostadapter2 driverModule  
alias eth0 tlan  
options scsi_mod max_scsi_luns=256 scsi_allow_ghost_devices=1  
where driverModule in the second and third lines is the name of the HBA  
driver module for accessing the storage system.  
When loading HBA drivers into the ramdisk, make sure that the HBA module  
name in /etc/syscong/kernel is the same as that used in the /etc/modules.conf  
file.  
iii. 3. Edit the /etc/modprobe.conf.local file as follows:  
^
For QLogic HBAs, make sure that the ql2xfailover and the CongRequired  
parameters are set to 0:  
options qla2xxx q12xfailover=0 CongRequired=0  
The variables x and xxx vary with the HBA model.  
^
For Emulex HBAs, set the value of the lpfc_nodev_tmo parmeter to 10:  
options lpfc lpfc_nodev_tmo=10  
iv. Run uname -r to display the kernel version.  
66  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
v. Run ls -l /boot to determine which initrd and vmlinuz files are used for the kernel  
version. (The names of both the initrd and vmlinuz files include the kernel  
version.)  
vi. Enter:  
/sbin/mk_initrd -k vmlinuz -i initrd  
where vmlinuz and initrd correspond to the configuration identified by ls - boot  
for the kernel version.  
STEP 4. Log in as root.  
STEP 5. If you are install PowerPath 4.5 and want the PowerPath installation messages to appear in  
Chinese (simplified), French, German, Italian, Japanese, Korean, Portuguese (Brazilian),  
or Spanish (Latin American), enter one of the following commands:  
export LANG=locale_ID.utf8  
or  
setenv LANG=locale_ID.utf8  
where locale_ID is defined in Table 2.  
If you set the LANG variable to unsupported locale ID, PowerPath continues the  
installation in English.  
TABLE 2.  
Language Locale ID  
Language  
Locale ID  
zh_CN.utf8  
En_US.utf8  
fr_FR.utf8  
de_DE.utf8  
it_IT.utf8  
Chinese (simplified)  
English  
French  
German  
Italian  
ja_JP.utf8  
ko_KR.utf8  
pt_BR.utf8  
es_ES.utf8  
Japanese  
Korean  
Portuguese (Brazliian)  
Spanish (Latin American)  
STEP 6. Insert the PowerPath CD into the server s CD drive.  
STEP 7. Create the directory /cdrom as the mount point for the CD:  
mkdir /cdrom  
STEP 8. Mount the PowerPath CD on /cdrom:  
romount -o ro /dev/cdrom /cdromm  
Intel Storage System SSR212PP User Guide  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STEP 9. Change to the LINUX directory for your kernel and revision of PowerPath that you are  
installing. For example,  
For a Red Hat 2.4 kernel and PowerPath 4.3.4:  
cd /cdrom/LINUX/2.4/pp4.3.4/rhel  
For a Red Hat 2.6 kernel and PowerPath 4.5:  
cd /cdrom/LINUX/2.6/pp4.5/rhel  
For a SuSE 2.4 kernel and PowerPath 4.3.4:  
cd /cdrom/LINUX/2.4/pp4.3.4/sles  
Fora SuSE 2.6 kernel and PowerPath 4.5:  
cd /cdrom/LINUX/2.6/pp4.5/sles  
STEP 10. Install PowerPath:  
rpm -ivh EMCpower.LINUX-version-build.package  
where version, build, and package are the version number, build number, and package  
name of PowerPath on the CD.  
You have completed the PowerPath installation. After running the rpm command, certain  
error messages may occur. The following acceptable warning appears when loading the  
PowerPath drivers:  
Warning: loading /lib/modules/’uname -r’ /kernel/drivers/addon/emcpower/emcp.o  
will taint the kernel:  
no license  
This message is expected and is acceptable behavior for loading a binary module.  
Initially, PowerPath attempts to load modules with version-checking enabled. If the  
pre-selected module load fails, the software silently (without issuing error  
messages) loads the module with version-checking disabled.  
STEP 11. Start PowerPath:  
/etc/init.d/PowerPath start  
Use the above command only for loading and unloading the EMC¤ PowerPath module.  
If the LANG variable is set to the locale ID listed in Table 2, the messages from the  
PowerPath start command are displayed in that language.  
STEP 12. Unmount the CD:  
cd / umount /cdrom  
STEP 13. Remove the PowerPath installation CD from the CD drive.  
STEP 14. For Linux, verify that all HBA, NIC and iSCSI HBA driver extensions are loaded:  
68  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If you loaded the HBA, NIC or iSCSI HBA driver as a module (not as a static kernel  
driver), use lsmod to verify that all extensions are loaded.  
If you built the HBA, NIC or iSCSI HBA driver as a module and modified  
/etc/modules.conf to specify that the driver be loaded before the PowerPath drivers, the  
driver name appears in the lsmod output below the PowerPath drivers. For example:  
ModuleSizeUsed byTainted: PF  
emcphr96240(unused)  
emcpmpap1050240(unused)  
emcpmpaa721600(unused)  
emcpmpc920640(unused)  
emcpmp558400(unused)  
emcp5425200[emcphr emcpmpap emcpmpaa  
emcpmpc emcpmp]  
emcpsf68200[emcpmpap emcp]  
...  
driver_module6843801  
sg mptscsih driver_module sd_mod]  
where driver_module is the name of the HBA, NIC or iSCSI HBA driver module.  
The /etc/modules.conf file should look similar to the following:  
alias pplter emcpsf  
pre-install emcpsf modprobe sd_mod  
add options emcp hostid=00:C0:9F:35:4A:30  
insmod_opt=-N  
alias power_path emcp  
add above emcp emcpmp  
add above emcpmp emcpmpc  
add above emcpmpc emcpmpaa  
add above emcpmpaa emcpmpap  
add above emcpmpap emcphr  
add above emcphr emcpioc  
post-install emcpioc rmmod emcpioc  
add options emcp managedclass="hpxp","ess","hitachi","hphsx"  
add below emcp driver_module  
alias scsi_pplteradapter driver_module  
post-install emcpsf modprobe driver_module  
pre-remove emcpsf rmmod emcpmpaa emcpmpc emcpmp emcp  
where driver_module is the name of the HBA, NIC or iSCSI HBA driver module.  
STEP 15. If the server is running SuSE Linux SLES8 and a kernel version newer than 2.4.21-138,  
rebuild the ramdisk:  
a. Edit the /etc/sysconfig/kernel file to ensure that the HBA driver is always loaded after  
the internal SCSI adapter driver as follows:  
INITRD_MODULES="scsi_mod sd_mod cciss reiserfs driver_module"  
Intel Storage System SSR212PP User Guide  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
where driver_module is the name of theHBA drivermodule used to access the storage  
system.  
For SuSE Linux, when loading HBA drivers into the ramdisk, make sure that  
the HBA module name used in /etc/sysconfig/kernel is the same as that used  
in the /etc/modules.conf file.  
b. Create the new ramdisk:  
mk_initrd -i /boot/ramdisk_name -k /boot/ kernel_image_name  
STEP 16. Check the PowerPath part of the "Register to download software" section on the  
SSR212PP support website for a patch to the version of PowerPath that you just installed.  
If such a patch is available, install it, as described in the readme file that accompanies the  
patch.  
70  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing PowerPath iSCI for  
Windows 2003 Server  
8
Installing PowerPath iSCSI for Windows 2003 Server  
If the server that you will connect to the storage system is running Windows 2003 Server,  
you must install PowerPath¤iSCSI on the server.  
PowerPath iSCSI manages the I/O paths between the server and storage system and is  
required for Microsoft MPIO-based failover.  
BeforeYou Start  
To complete this procedure, you need to  
Locate the PowerPath iSCSI CD that shipped with the storage system.  
Locate the card with the PowerPath license key that shipped with the storage system.  
For information on integrating PowerPath iSCSI into an existing MSCS cluster,  
refer to the PowerPath for Windows Installation and Administrator s Guide on the  
SSR212PP support website.  
STEP 1. Insert the PowerPathor PowerPath iSCSI installation CD in the server s CD drive.  
STEP 2. If autoplay is enabled on your server, start the installation as follows:  
a. When the Getting Started page appears, click the appropriate link in the Installation  
section for the server s operating system.  
b. Select Run this program from its current location (or similar message depending on  
your browser) and click OK.  
You can install the software from the Installation section by clicking the appropriate  
link for your operating system.  
STEP 3. If autoplay is not enabled on the server, start the installation as follows:  
a. On the Windows taskbar, select StartRun.  
b. In the Run window, enter the name of the appropriate installation program below, and  
click OK.  
For 32-bit Windows Server 2003: d:\2003\EMCPP.W2003_32. x.y.z.GA.exe  
For 64-bit Windows Server 2003: d:\2003\EMCPP.W2003.64.x.y.z.GA.exe  
where d is the CD drive letter and x.y.z is the revision of PowerPath on the CD.  
Intel Storage System SSR212PP User Guide  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
If you do not know whether your Windows 2003 Server is 32-bit or 64-bit, right-click  
on My Computer and select Manage. Select System InformationSystem Summary.  
View the System Type option. If x86 displays, you have a 32 bit system. If IA64 or  
AMD64 displays, you have a 64 bit system.  
Alternatively, double-click the platform-specific .exe icon in the appropriate directory  
on the CD.  
STEP 4. In the setup wizard Welcome window, click Next.  
STEP 5. Enter your name and organization and click Next.  
STEP 6. In the Custom Setup dialog box, select Next (you cannot connect any third-party storage  
systems to the server). It is recommended that you install PowerPath iSCSI in the default  
directory.  
CAUTION  
If you want to specify another directory, do not specify the Windows System  
directory for your system (specified by the %SYSTEMROOT% environmental  
variable). PowerPath will not function correctly if it is installed in this directory.  
STEP 7. In the Ready to Install the Program dialog box, click Install.  
STEP 8. If the Licensing Tool is displayed, enter your 24-digit SSR212PP-Series registration  
number in the License Key field, then click Add and OK.  
Type the registration number, including the dashes, exactly as written on the card  
you received with the software. To reduce common typographical errors, the  
License Key field accepts either uppercase or lowercase letters, and certain  
numbers and letters are interchangeable. Specifically, entering the alphabetic letters  
O, I, S, and B is equivalent to entering the numbers, 0, 1, 5, and 8.  
If you have additional questions about entering licenses, consult the online help file  
by pressing F1 from the EMC Licensing Tool. You must have Internet Explorer 5.0  
or higher to view these files. If you do not have this browser installed, you may still  
view the help file, EmcLicTool.chm, directly from the \help folder on the PowerPath  
installation CD.  
STEP 9. In the InstallShield Wizard Completed dialog box, click Finish.  
STEP 10. When the setup wizard asks whether you want to reboot the host, click Yes.  
Upgrading from PowerPath to PowerPath iSCSI  
PowerPath iSCSI is required for Microsoft MPIO-based failover. See the PowerPath  
release notes for supported operating system versions.  
72  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CAUTION  
This procedure requires that you reboot the server that you want to upgrade.  
BeforeYou Start  
Verify that the server is running PowerPath version 4.3.1 or higher.  
Obtain the latest version of PowerPath iSCSI on a CD or download it from the SSR212PP  
support website.  
STEP 1. Uninstall PowerPath:  
a. Close all applications and client files on the server that are sending data to or receiving  
data from the storage system; that is stop I/O to the system.  
b. When I/O is stopped, uninstall PowerPath using Add/Remove Programs:  
i. Open the Control Panel, double-click Add/Remove Programs.  
For Windows 2000 or Windows Server 2003, select the PowerPath 32-bit  
version or the PowerPath 64-bit version depending on whether you have  
installed the 32-bit or 64-bit package.  
ii. Click Remove.  
iii. When prompted to remove PowerPath, click Yes.  
iv. When prompted to restart the host, click Yes.  
c. Restart all applications on the server.  
STEP 2. Install PowerPath iSCSI using the procedure just described.  
For information on integrating PowerPath iSCSI into an existing MSCS cluster,  
refer to the PowerPath for Windows Installation and Administrator s Guide on the  
SSR212PP support website.  
Installing a PowerPath or PowerPath iSCSI Patch  
Check the PowerPath part of the Register to download software section on the SSR212PP  
support website for a patch to the version of PowerPathor PowerPath iSCSI that you just  
installed. If such a patch is available, install it, as described in the readme file that  
accompanies the patch.  
Intel Storage System SSR212PP User Guide  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
74  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the Navisphere  
Server Utility  
9
Read this section for all configurations.  
You must install the Navisphere Server Utility on each server connected to the storage  
system. If you do not disable the Registration Service option during the installation (it is  
enabled by default), the Server Utility automatically registers the server s HBAs with the  
storage system.  
BeforeYou Start  
To complete this procedure, you need the SSR212PP-Series Server Support Products CD  
that shipped with the storage system. If your server is connected only to an SSR212PPf or  
SSR212PP2f storage system and is running Navisphere Server Utility version 2.19 or  
lower, you must install the later version that shipped with your SSR212PPf or  
SSR212PP2f storage system.  
Installing the Navisphere Server Utility on a Windows Server  
STEP 1. Insert the SSR212PP-Series Server Support Products CD into the server s CD.  
STEP 2. Select your language, if prompted for it.  
STEP 3. From the main menu, click Install Products on Server.  
STEP 4. From the Install Products menu, click Navisphere Server Utility to open the installation  
wizard.  
STEP 5. Follow the instructions on the screen and accept all the defaults.  
Do not disable the Registration Service option (it is enabled by default as part of the  
Complete setup type). The Registration Service option automatically registers the  
server s HBAs with the storage system after the installation and updates server  
information to the storage system whenever the server configuration changes (for  
example, you mount new volumes or create new partitions).  
STEP 6. If you are prompted about updating information when the server starts, click Yes.  
STEP 7. If you are prompted to reboot the server, click Yes.  
STEP 8. Click Finish to exit the wizard.  
STEP 9. Remove the CD from the server s CD drive.  
Intel Storage System SSR212PP User Guide  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installing the Navisphere Server Utility on a Linux Server  
STEP 1. Insert the SSR212PP-Series Server Support Products CD into the server s CD drive.  
STEP 2. Install the Navisphere Server Utility on the server:  
rpm -i naviserverutil-version-build.platform.rpm  
where version and build are the version number and the build number of the Navisphere  
Server Utility on the CD (for example, 6.17.1.1.27-1) and platform is your Linux platform  
number (for example, i386, ia64, or x86-64).  
For a SuSE ia64 system, use t  
rpm -i naviserverutil_suse-version-build.platform.rpm  
If you are upgrading the utility on the server, use -u in place of -i.  
The installation process adds a line to the /etc/rc.d/rc.local file that starts the server utility  
on reboot, provided root has execute permission for the /etc/rc.d/rc.local file.  
STEP 3. Remove the CD from the server s CD drive.  
76  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Unpacking the SSR212PP-  
Series Storage System  
10  
CAUTION  
The equipment is heavy and should be installed into a rack by two people. To  
avoid personal injury and/or damage to the equipment, do not attempt to lift and  
install the unit into a rack without a mechanical lift and/or help from another  
person.  
STEP 1. Unpack the storage system as shown on the shipping carton.  
CAUTION  
The disks in slots marked 0-2 (SSR212PPf, single-SP storage system) and slots  
marked 0-3 (SSR212PP2f, dual-SP storage system) are preloaded with storage  
system software according to their slot assignment before shipment. Do not move  
a preloaded disk from its assigned slot to another slot. Doing so causes the  
storage system to function improperly. Remove a preloaded disk only to replace  
it.  
0
1
2
3
EMC2794a  
FIGURE 23. Location of Disks 0–3  
STEP 2. Locate and record the serial number of the storage system (Figure 24).  
You will need this number later when you initialize the storage system.  
Intel Storage System SSR212PP User Guide  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
HW S/N XXX 000NNNNNNNN  
EMC3263  
FIGURE 24. Locating the Storage System Serial Number  
78  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the SSR212PP-  
Series Storage System  
11  
Read this section if you are installing a new storage system.  
Install the storage system in a 19-inch NEMA-standard cabinet/rack.  
BeforeYou Start  
To complete this procedure, you need the mounting hardware that shipped with the storage  
system.  
Installing the Storage System in a Cabinet  
STEP 1. Install each rail in the cabinet (Figure 25):  
a. From the front of the cabinet, insert the alignment pins in the rear channel of the  
cabinet.  
Insert the pins in the 1/2-inch space between channel holes, which aremarked by a  
dash ( ) in some cabinets.  
b. Pull the adjustable rail forward, and attach it with two screws to the inside of the front  
channel in the two center holes.  
c. From the rear of the cabinet, secure each rail to the rear channel. Leave the screws  
slightly loose to allow for adjustment after you load the storage system on the rails.  
Intel Storage System SSR212PP User Guide  
79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Alignment Pins  
Adjustable Rail  
Right Rear  
Right Front  
Screw (2)  
Screw (2)  
Alignment  
Pin (2)  
Mounting Rail  
Mounting Rail  
EMC2829  
FIGURE 25. Installing Mounting Rails in a 19-inch NEMA Cabinet  
STEP 2. If the front bezel is attached, remove it.  
STEP 3. Remove the four screws that are secured with washers and nuts to the black plastic latch  
brackets and discard the washers and nuts (Figure 26).  
EMC3035  
FIGURE 26. Removing the Latch Bracket Screws, Washers, and Nuts  
CAUTION  
The equipment is heavy and should be installed into a rack by two people. To  
avoid personal injury and/or damage to the equipment, do not attempt to lift and  
80  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
install the unit into a rack without a mechanical lift and/or help from another  
person.  
STEP 4. From the front of the cabinet, slide the storage system onto the rails so that the cutouts in  
the rear of the chassis fit into the tabs on the back of each rail ( Figure 27).  
If the chassis does not slide all the way into the cabinet, you may need to further loosen  
the screws that hold the rear of the rails in place; then adjust the rail to allow the tabs to fit  
into the cutouts.  
EMC2799  
FIGURE 27. Sliding the Chassis into the Cabinet  
STEP 5. Use the four latch bracket screws to secure the storage system and latch brackets to each  
front channel (Figure 28).  
STEP 6. Snap the front bezel onto the storage system (Figure 28).  
AF000637  
FIGURE 28. Securing the Chassis and Installing the Front Bezel  
Intel Storage System SSR212PP User Guide  
81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
82  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Second  
Power Supply  
12  
Read this section if you received a second power supply for your single-SP storage  
system.  
You may receive a second power supply that looks slightly different from the  
original, and/or different from the illustrations in this note. The two versions are  
functionally the same.  
For greater clarity, the illustrations in this note show the storage system chassis  
independent of a cabinet or deskside mounting hardware.  
STEP 1. Read "Handling Field-Replaceable Units (FRU)" on page 59. If possible, have an ESD  
wriststrap attached to your wrist as you perform the following steps.  
STEP 2. Push the slide latch to the left as you pull the power supply filler module straight out of the  
chassis (Figure 29).  
Slide Latch  
EMC3255  
FIGURE 29. Removing a Power Supply Filler Module  
STEP 3. Gently insert the new power supply straight into the storage system, being sure to  
completely seat the supply (Figure 30).  
Intel Storage System SSR212PP User Guide  
83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
EMC3256  
FIGURE 30. Installing a Second Power Supply  
STEP 4. Pull the wire retention bail out of the way, plug the power cord into the new power supply,  
and attach the retention bail for strain relief (Figure 31).  
Retention  
bail  
EMC3297  
EMC3297  
FIGURE 31. Plugging in the Power Cord  
STEP 5. If power is not on, press the power button to begin powerup, and verify that the power  
supply fault indicator light does not go on (Figure 32).  
84  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Power Supply B Fault LED  
PS B On  
Power Supply A Fault LED  
PS A On  
SP B Boot/Fault LED  
Power LED  
Power On/Off Button  
SP A Boot/Fault LED  
EMC3272  
FIGURE 32. Power button and Indicators for an SSR212PPf with Two Power  
Supplies  
Intel Storage System SSR212PP User Guide  
85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
86  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Disk Module  
13  
This procedure describes how to install a disk module in an SSR212PP-Series storage  
system.  
For greater clarity, the illustrations in this document show the storage system chassis  
independent of a cabinet or deskside mounting hardware.  
Handling Disk Modules  
Disk modules are extremely sensitive electronic components. Always handle a disk  
module gently, and observe the following guidelines:  
Whenever possible or practical, replace a disk module with another of the same  
model. Refer to the SSR212PP support website for a list of approved disk  
replacements.  
Follow the instructions in the section on handling FRUs in this document.  
Disk modules are sensitive to the extreme temperatures sometimes encountered  
during shipping. It is recommended that you leave new disk modules in their shipping  
material, and expose the package to ambient temperature for at least four hours before  
attempting to use the new modules in your system.  
Wear a properly attached ESD wristband when removing or replacing a disk module.  
When removing a disk module, pull the module partially out of the slot, then wait 30  
seconds for the drive to spin down before removing it.  
Place modules on a soft, antistatic surface, such as an industry-standard antistatic  
foam pad or the container used to ship the module. Never place a disk module directly  
on a hard surface.  
Never hit modules, stack modules, or allow them to tip over or fall.  
Avoid touching any exposed electronic components and circuits on the disk module.  
Do not remove a faulty disk module until you have a replacement module (with the  
same or an approved part number) or a filler module available. The part number  
(PN005xxxxxx) appears on the front of the module.  
STEP 1. Read "Handling Field-Replaceable Units (FRU)" on page 59. If possible, have an ESD  
wriststrap attached to your wrist as you perform the following steps.  
STEP 2. Unlock and remove the front bezel.  
Intel Storage System SSR212PP User Guide  
87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CAUTION  
The bezel is required for EMI compliance when the storage system is powered  
up. Remove it only to replace or add a disk module.  
a. Insert the key that shipped with your storage system into the bezel lock, and turn it to  
release the lock (Figure 33).  
b. Press the two latch buttons on the bezel surface toward each other to release the bezel  
from the cabinet (Figure 33).  
c. Pull the bezel off the cabinet and put it on a clean, static-free surface.  
SAB2937  
FIGURE 33. Unlocking and Removing the Front Bezel  
STEP 3. Locate the slot where you want to install the disk module, and remove the filler module  
(Figure 34).  
Filler  
EMC2810  
FIGURE 34. Removing a Disk Filler Module  
88  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
STEP 4. Install the disk module.  
CAUTION  
The disk module you install must have a green handle. Do not install a disk  
module with a blue-grey or dark metallic grey handle. If you are installing  
multiple disk modules in a storage system that is powered up, wait at least 10  
seconds before sliding the next disk module into position.  
a. Align the replacement module with the guides in the slot.  
b. Gently push the module completely into the slot, and ensure that the module seats  
completely by pushing in on the disk label as you engage the latch (Figure 35). The  
disk module Active light flashes to indicate the disk spin-up sequence.  
Disk  
Label  
(Push Here)  
EMC2812  
FIGURE 35. Installing a Disk Module  
STEP 5. Install and lock the front bezel:  
a. Align the bezel with the storage system (Figure 36).  
b. Gently push the bezel into place on the cabinet until it latches (Figure 36).  
c. Secure the bezel by turning the key in the lock (Figure 36).  
Intel Storage System SSR212PP User Guide  
89  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SAB2935a  
FIGURE 36. Installing and Locking the Front Bezel  
90  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connecting AC Power to a  
Single-SP Storage System  
14  
This section describes how to connect power to an SSR212PPf (single-SP) storage  
system.  
BeforeYou Start  
To complete this procedure, you need the AC power cables appropriate to your power  
source. These cables shipped with the storage system.  
STEP 1. For each power supply in the storage system, plug a storage system power cord into the  
power connector on each power supply in the storage system (Figure 37 or Figure 38).  
O F F  
O F F  
O
O
I
I
O N  
O N  
O F F  
O N  
O F F  
O N  
O
O
I
I
O F F  
O N  
O F F  
O N  
O
O
I
I
EMC3277  
FIGURE 37. Connecting AC Power to an SSR212PPf or SSR212PPi with One Power  
Supply  
Intel Storage System SSR212PP User Guide  
91  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
O F F  
O F F  
O
O
I
I
O N  
O N  
O F F  
O N  
O F F  
O N  
O
O
I
I
O F F  
O N  
O F F  
O N  
O
O
I
I
EMC3296  
FIGURE 38. Connecting AC Power to an SSR212PPf or SSR212PPi withTwo Power  
Supplies  
STEP 2. For each power supply in the storage system, secure the power cord with the retention bail  
at the connector (Figure 39).  
The retention bail prevents the power cord from pulling out of the connector and causing  
the storage system to power down unexpectedly.  
Retention  
Bail  
EMC3265  
FIGURE 39. Securing the Power Cord with a Retention Bail  
92  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
STEP 3. For each power supply in the storage system, plug the storage system power cord into the  
AC power source in the cabinet (power distribution unit) or other source (Figure 37 or  
The power supply on light turns on indicating that the power supply is connected to an  
active AC power source.  
STEP 4. If the storage system will be connected to the server through a switch, plug one end of  
the switch power cord to the power connector on the switch and the other end into an AC  
power source, as described in the documentation that shipped with the switch.  
STEP 5. Press the storage system power on/off button to initiate powerup (Figure 40 or Figure 41).  
CAUTION  
Press the power button only briefly to power up the storage system. Pressing the  
power button for more than four seconds while the storage system powers up  
may affect initialization parameters.  
The green power lights (LEDs) on the front and back of the storage system turn on and  
remain on as long as power is applied to the storage system (Figure 40 and Figure 41 or  
Figure 42). The amber SP Boot/Fault light flashes to indicate powerup progress. The Disk  
Activity lights on the front of the storage system light intermittently as the disks spin up  
and disk I/O begins.  
When powerup is complete (usually in 5 to 6 minutes), the SP Boot/Fault light goes off. If  
the storage system does not power up within several minutes and/or the fault indicator  
goes on, refer to the "Troubleshoot" section on the SSR212PP support website or the  
SSR212PP-Series Documentation CD.  
Fault  
Power  
Disk Activity  
SAB2934  
Lock  
FIGURE 40. Storage System Front LEDs  
Intel Storage System SSR212PP User Guide  
93  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Power Supply A Fault LED  
Power Supply A On  
Power LED  
Power On/Off Button SP A Boot/Fault LED  
EMC3285  
FIGURE 41. Power Button and Rear LEDs on an SSR212PPf with One Power  
Supply  
Power Supply B Fault LED  
PS B On  
Power Supply A Fault LED  
PS A On  
Power LED  
Power On/Off Button  
SP A Boot/Fault LED  
EMC3328  
FIGURE 42. Power Button and Rear LEDs on an SSR212PPf with Two Power  
Supplies  
If the amber System Fault light is on after powerup, a fault exists somewhere in the  
storage system. If the amber light specific to a power supply, SP, or disk is on, then that  
part is faulted.  
Powering the Storage System Down  
For an orderly shutdown that protects your cache data, use the storage system power  
button. The storage system takes a full minute to power down after you press the power  
button. So after powering down the storage system, wait one minute before powering it on  
again. If storage system power is turned off by the power button or by a software  
shutdown, you must press the power button to reapply power. If you power down the  
storage system by unplugging the power cord, the storage system powers up as soon as it  
is reconnected to the AC power source.  
94  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Connecting AC Power to a  
Dual-SP Storage System  
15  
BeforeYou Start  
To complete this procedure, you will need  
The sense cable, which is the serial cable that shipped with the UPS. This cable allows  
Navisphere Express to monitor UPS status.  
The AC power cables appropriate to your power source. These cables shipped with the  
storage system.  
CAUTION  
You must connect the UPS serial cable to the purple UPS (+ -) port on SPA. This  
connection is required for write-cache operation, and allows Navisphere Express  
to monitor the UPS. A standard null-modem or other service serial cable may  
look identical to the unique serial cable supplied with the UPS, but it will not  
work. Be sure to use the unique serial cable that came with the UPS.  
STEP 1. Plug one end of the UPS serial cable into the serial port on the UPS (Figure 43).  
STEP 2. Plug the free end of the UPS serial cable into the UPS connector (labeled with a +- battery  
icon) on SP A (Figure 43).  
O F F  
O F F  
O
O
I
I
O N  
O N  
O F F  
O N  
O F F  
O N  
O
O
I
+ -  
I
UPS  
O F F  
O N  
O F F  
O N  
O
O
UPS Serial cable  
I
I
Power Cords  
EMC3264  
FIGURE 43. Connecting the UPS Serial Cable to an SSR212PP2f or SSR212PP2i  
Intel Storage System SSR212PP User Guide  
95  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
STEP 3. Plug a storage system power cord into the power connector power supply in the storage  
system (Figure 44).  
O F F  
O F F  
O
O
I
I
O N  
O N  
O F F  
O N  
O F F  
O N  
O
O
I
+ -  
I
UPS  
O F F  
O N  
O F F  
O N  
O
O
UPS Serial cable  
I
I
Power Cords  
EMC3264  
FIGURE 44. Connecting AC Power to an SSR212PP2f or SSR212PP2i  
STEP 4. Secure each power cord with the retention bail at the connector (Figure 45).  
The retention bail prevents the power cord from pulling out of the connector and causing  
the storage system to power down unexpectedly.  
Retention  
Bail  
EMC3279  
FIGURE 45. Securing the Power Cord with the Retention Bail  
96  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
STEP 5. Plug each storage system power cord into an AC power source as follows (Figure 44):  
CAUTION  
Do not connect more than one power supply to the UPS.  
a. Plug the storage system power cord connected to the SP A power supply into the  
power outlet on the UPS.  
b. For a 100V or 120V UPS, plug the attached UPS power cord into an AC power  
source.  
c. For a 230V UPS, plug one end of the loose UPS power cord into the UPS power outlet  
and the other end into an AC power source in the cabinet (power distribution unit).  
d. Turn on UPS power as described in the documentation that shipped with the UPS.  
e. Plug the power cord connected to the SP B power supply into the AC power source in  
the cabinet (power distribution unit).  
Do not connect the SP B power supply to the same power source/circuit as  
the UPS.  
On each power supply, the power supply on light turns on indicating that the power  
supply is connected to an active AC power source.  
STEP 6. If the storage system will be connected to the server through a switch, plug one end of  
the switch power cord to the power connector on the switch and the other end into an AC  
power source, as described in the documentation that shipped with the switch.  
STEP 7. Press the storage system power on/off button to initiate powerup (Figure 46).  
CAUTION  
Press the power button only briefly to power up the storage system. Pressing the  
power button for more than four seconds while the storage system powers up  
may affect initialization parameters.  
The green power lights (LEDs) on the front and back of the storage system turn on and  
amber SP Boot/Fault light flashes to indicate powerup progress. The Disk Activity lights  
on the front of the storage system light intermittently as the disks spin up and disk I/O  
begins.  
When powerup is complete (usually in 5 to 6 minutes), the SP Boot/Fault light goes off. If  
the storage system does not power up within several minutes and/or the fault indicator  
goes on, refer to the "Troubleshoot" section on the SSR212PP support website or the  
SSR212PP-Series Documentation CD.  
Intel Storage System SSR212PP User Guide  
97  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fault  
Power  
Disk Activity  
SAB2934  
Lock  
FIGURE 46. Storage System Front LEDs  
Power Supply B Fault LED  
PS B On  
Power Supply A Fault LED  
PS A On  
SP B Boot/Fault LED  
Power LED  
Power On/Off Button  
SP A Boot/Fault LED  
EMC3272  
FIGURE 47. SSR212PP2f Storage System Power Button and Rear LEDs  
If the amber System Fault light is on after powerup, a fault exists somewhere in the  
storage system. If the amber light specific to a power supply, SP, or disk is on, then that  
part is faulted.  
Powering the Storage System Down  
For an orderly storage system shutdown that protects your cache data, use the storage  
system power button (not the UPS power switch). The storage system takes a full minute  
to power down after you press the power button. So after powering down the storage  
system, wait one minute before powering it on again. If storage system power is turned off  
by the power button or by a software shutdown, you must press the power button to  
reapply power. If you power down the storage system by unplugging the power cord, the  
storage system powers up as soon as it is reconnected to the AC power source.  
98  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Connecting the Management  
Ports to the LAN  
16  
BeforeYou Start  
To complete this procedure, you need a standard CAT 5, CAT 5e, or CAT 6 network cable  
for:  
Each management port on each storage system SP that you will connect to the LAN.  
Each Fibre Channel switch, if you are using them, and if you want to manage with the  
switch vendor s management software.  
STEP 1. For each SP, connect one end of a LAN cable to the management port on the SP and the  
other end to the network from which you will manage the storage system(Figure 48 or  
Be sure you do not connect the management LAN cable to the serial/service or UPS  
ports. If you connect the management ports directly to a network switch, you must  
use switch ports that support auto-negotiation or are configured for half-duplex  
operation.  
Management  
LAN port  
Service  
Management LAN  
CAT-5, -5E, -6 Cable  
EMC3276  
FIGURE 48. SSR212PPf Management LAN Port Connections  
Intel Storage System SSR212PP User Guide  
99  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
SP B  
Management  
LAN Port  
Service  
UPS  
SP A  
Management  
LAN Port  
Service  
10/100/1000 LAN  
CAT-5, 5E, 6 Cables  
EMC3267  
FIGURE 49. SSR212PP2f Storage System Management LAN Port Connections  
STEP 2. If your configuration emplys one or more Fibre Channel switches,  
a. If you want to use the switch management software, connect one end of a LAN cable  
to the LAN management port on each switch and the other end to the network from  
which you will manage the switch (Figure 50 or Figure 51). You must use switch  
management software to zone switches that are not hard zoned.  
To LAN  
Switch  
O F F  
O
O F F  
O
I
I
!
O N  
O N  
0
4
1
5
2
6
3
7
O F F  
O N  
O F F  
O N  
O
O
I
I
To LAN  
EMC3292  
FIGURE 50. SSR212PPf Storage System and Switch LAN Connections  
100  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
To LAN  
To LAN  
Switch  
O F F  
O
O F F  
O
I
I
!
O N  
O N  
0
4
1
5
2
6
3
7
O F F  
O N  
O F F  
O N  
O
O
I
I
To LAN  
EMC3293  
FIGURE 51. SSR212PP2f Storage System and Switch LAN Connections  
b. If the switch is not hard-zoned, locate the zoning wizard CD that shipped with the  
switch.  
c. Using the instructions provided with the CD, run the zoning wizard and select the  
zone configuration that is applicable to the way you connected the storage system SP  
ports and the server HBA ports to the switch.  
Intel Storage System SSR212PP User Guide  
101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
102  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the Navisphere  
Storage System  
17  
Initialization Utility  
BeforeYou Start  
You will need the SSR212PP-Series Server Support Products CD for this procedure.  
Installing on a Windows Host  
STEP 1. Insert the SSR212PP-Series Server Support Products CD into the CD drive of a Windows  
host on the same subnet as the storage system.  
STEP 2. Select your language, if prompted for it.  
STEP 3. From the main menu, click Install Utilities on Server.  
STEP 4. From the Install Products menu, click Navisphere Storage System Initialization Utility to  
open the installation wizard.  
STEP 5. Proceed until the installation is complete. A user interface (UI) and a text-based version of  
the utility are installed.  
STEP 6. Remove the CD from the host s CD drive.  
Installing on a Linux Host  
STEP 1. Insert the SSR212PP-Series Server Support Products CD into the CD drive of a Linux  
host on the same subnet as the storage system.  
STEP 2. Install the Navisphere Storage System Initialization Utility on the Linux host :  
rpm -ivh naviinittool-version-build.i386.rpm  
where version and build are the version number and the build number of the Navisphere  
Storage System Initialization Utility on the CD. For example, 6.19.1.1.10.  
If you are upgrading the utility on the server, use -U in place of -i.  
STEP 3. When installation is complete, remove the CD from the host s CD drive.  
Intel Storage System SSR212PP User Guide  
103  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
104  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Running the Navisphere  
Storage System Initialization  
Utility on a FC Conguration  
18  
STEP 1. Start the Navisphere Storage System Initialization Utility:  
On a Windows host, click  
Start Programs EMC Navisphere Navisphere Storage System Initialization.  
On a Linux host, enter:  
cd /opt/Navisphere/bin/naviinittoolcli  
STEP 2. Read the license agreement.  
On Windows, click I accept and Next.  
On Linux, enter y to accept it.  
The utility automatically scans the subnet for SSR212PP-Series storage systems. When  
this storage system discovery operation is complete, the utility lists, by hardware serial  
number, all uninitialized and initialized storage systems it discovered. The hardware serial  
number (HW S/N XXX 000NNNNNNNN) is on a label on the rear of the chassis.  
If the storage system you are installing was not discovered, verify the cable connections  
between the storage system and the server running the utility.  
STEP 3. Select a storage system to initialize.  
On a Windows host, select the storage system from the Uninitialized Systems list and  
and click Next.  
On a Linux host, enter the item number of the storage system you want to initialize  
and press ENTER.  
Configuration," on page 1, follow the instructions on the screen to change the storage  
system s name, if desired, and to set the following network parameters for the storage  
system management ports:  
Parameter  
Descritpion  
Storage Processor A - IP ADDRESS  
Storage Processor B - IP ADDRESS  
Subnet Mask  
IP address for SP A management port.  
IP address for SP B management port.  
Subnet mask associated with the LAN to which the  
storage system management port is connected.  
Default Gateway  
Default gateway address for the LAN to which the  
storage system management port is connected.  
STEP 5. Enter the name you want for the storage system; it cannot exceed 32 characters.  
Intel Storage System SSR212PP User Guide  
105  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Configuration," on page 1, follow the instructions on the screen to set the following  
management user account settings for the storage system:  
Account Setting  
Description  
User name  
Username for the management port. A valid  
username must start with a letter, can contain only  
letters and numbers, cannot exceed 32 characters, and  
is case—sensitive. For exampleb, lindmice3 is a valid  
username and is different from BLINDMICE3.  
Password  
Password for the user connected to the management  
port. A valid password can contain only letters and  
numbers, cannot exceed 32 characters, and is case—  
sensitive. For example, mousetrap2 is a valid  
password and is a different password from  
MOUSETRAP2.  
Conrm Password  
Previously entered password for password  
verification.  
STEP 7. Review and apply the settings.  
On a Windows host,  
i. Click Next to view the summary of the management user account settings for  
storage system.  
ii. In the message box about the storage system having been initialized, click OK.  
iii. If the settings are correct, click Finish.  
On a Linux host,  
i. Apply the values by typing a.  
ii. Exit the utility by typing e.  
If you entered an SP IP address for the first time or changed an SP IP address, the utility  
reboots the storage system and the SP Boot/Fault light on the back of each SP starts  
blinking (Figure 51 on page 118 or Figure 52 on page 118). The reboot takes several  
minutes to complete. When it is completed, the SP Boot/Fault light on each SP stops  
blinking and remains off.  
Changing the Management Network and Account Settings  
STEP 2. Reset the storage system: At least one minute after the storage system shuts down, press  
the power button, hold it down for at least four seconds, and then release it. When the  
start-up is complete, the storage system is uninitialized. You must rerun the Navisphere  
Initialization Utility to reset the management network parameters and the user account  
settings.  
STEP 3. Rerun the Navisphere Initialization Utility to set the parameters.  
106  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Running Navisphere Storage  
System Initialization Utility  
on a iSCSI Conguration  
19  
STEP 1. Start the Navisphere Storage System Initialization Utility:  
On a Windows host, click  
Start Programs EMC Navisphere Navisphere Storage System Initialization.  
On a Linux host, enter:  
cd /opt/Navisphere/bin/naviinittoolcli  
STEP 2. Read the license agreement.  
On Windows, click I accept and Next.  
On Linux, enter y to accept it.  
The utility automatically scans the subnet for SSR212PP-Series storage systems. When  
this storage system discovery operation is complete, the utility lists, by hardware serial  
number, all uninitialized and initialized storage systems it discovered. The hardware serial  
number (HW S/N XXX 000NNNNNNNN) is on a label on the rear of the chassis.  
If the storage system you are installing was not discovered, verify the cable connections  
between the storage system and the server running the utility.  
STEP 3. Select a storage system to initialize.  
On a Windows host, select the storage system from the Uninitialized Systems list and  
and click Next.  
On a Linux host, enter the item number of the storage system you want to initialize  
and press ENTER.  
page 15, follow the instructions on the screen to change the storage system s name, if  
desired, and to set the following network parameters for the storage system management  
ports:  
Parameter  
Descritpion  
Storage Processor A - IP ADDRESS  
Storage Processor B - IP ADDRESS  
Subnet Mask  
IP address for SP A management port.  
IP address for SP B management port.  
Subnet mask associated with the LAN to which the  
storage system management port is connected.  
Default Gateway  
Default gateway address for the LAN to which the  
storage system management port is connected.  
Intel Storage System SSR212PP User Guide  
107  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
STEP 5. For each iSCSI data port on each SP that you will use, set the following port paramters,  
where X is the storage-system SP (A or B) and Y is the SP s data port number (0 or 1):  
Parameter  
Description  
SP X Port Y IP ADDRESS  
SP X Port Y Subnet Mask  
IP address for the iSCSI data port.  
Subnet mask associated with the LAN to which the  
iSCSI data port will connect.  
SP X Port Y Direct Attach  
SP X Port Y Gateway  
Gateway address of 0.0.0.0 that you cannot change.  
Set this parameter only if the iSCSI data port will  
connect directly to the server and not through a LAN.  
Default gateway address for the LAN to which the  
iSCSI data port will connect.  
STEP 6. Enter the name you want for the storage system; it cannot exceed 32 characters.  
page 15, follow the instructions on the screen to set the following management user  
account settings for the storage system:  
Account Setting  
Description  
User name  
Username for the management port. A valid  
username must start with a letter, can contain only  
letters and numbers, cannot exceed 32 characters, and  
is case—sensitive. For exampleb, lindmice3 is a valid  
username and is different from BLINDMICE3.  
Password  
Password for the user connected to the management  
port. A valid password can contain only letters and  
numbers, cannot exceed 32 characters, and is case—  
sensitive. For example, mousetrap2 is a valid  
password and is a different password from  
MOUSETRAP2.  
Conrm Password  
Previously entered password for password  
verification.  
STEP 8. Review and apply the settings.  
On a Windows host,  
i. Click Next to view the summary of the management user account settings for  
storage system.  
ii. In the message box about the storage system having been initialized, click OK.  
iii. If the settings are correct, click Finish.  
On a Linux host,  
i. Apply the values by typing a.  
ii. Exit the utility by typing e.  
108  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If you entered an SP IP address for the first time or changed an SP IP address, the utility  
reboots the storage system and the SP Boot/Fault light on the back of each SP starts  
blinking (Figure 51 on page 118 or Figure 52 on page 118). The reboot takes several  
minutes to complete. When it is completed, the SP Boot/Fault light on each SP stops  
blinking and remains off.  
Changing the Management Network and Account Settings  
STEP 2. Reset the storage system: At least one minute after the storage system shuts down, press  
the power button, hold it down for at least four seconds, and then release it. When the  
start-up is complete, the storage system is uninitialized. You must rerun the Navisphere  
Initialization Utility to reset the management network parameters and the user account  
settings.  
STEP 3. Rerun the Navisphere Initialization Utility to set the parameters.  
Intel Storage System SSR212PP User Guide  
109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
110  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Shutting the Storage  
System Down  
20  
You can shut down the storage system with Navisphere Express or the power button.  
Shutting the Storage System Down with Navisphere Express  
STEP 2. In the Navisphere Express navigation pane under System, click Service.  
STEP 3. In the System Shutdown page, click Shutdown.  
Shutting the Storage System Down Using the Power Button  
Press the power button for about a second (Figure 52 or Figure 53).  
Power On/Off Button  
Power LED  
EMC3282  
FIGURE 52. SSR212PPf Storage System Power Button and Light (LED)  
Power On/Off Button Power LED  
EMC3269  
FIGURE 53. SSR212PP2f Storage System Power Button and Light (LED)  
Intel Storage System SSR212PP User Guide  
111  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
112  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting a Fibre Channel  
Storage System to the Server  
21  
Use optical cables to connect storage system fibre ports (labeled FE 0 and FE 1 on each  
SP) to server HBA ports.  
BeforeYou Start  
To complete this procedure, you need an optical cable for each SP port that you will use on  
the storage system. For cable specifications, refer to Technical Specifications on the  
SSR212PP support website.  
Handling Optical Cables  
Optical cables are susceptible to damage, so take the following precautions when handling  
them:  
Keep the covers on all optical cables until you are ready to insert them.  
Avoid tight bends. If you need to make a 90… bend, do it over 6 to 12 inches.  
Do not use optical cables to support weight (including their own unsupported weight  
if they are long).  
Do not pull long runs of cable; instead, lay the cable in place or pull only a few feet at  
a time.  
Place the cables where no one can step on them or roll equipment over them.  
Cabling the Storage System to the Server  
For the highest availability with a multiple-HBA server  
For configurations with a direct connection between the storage system and the server:  
For an SSR212PPf (single-SP) storage system, connect FE 0 to one HBA and FE  
1 to the other HBA  
For an SSR212PP2f (dual-SP) storage system, if the server has twoHBAs,  
connect one HBA to either FE port on SP A and the other HBA to either FE port  
on SP B. If the server has four HBAs, connect one HBA to each FE port on each  
SP.  
For configurations utilizing Fibre Channel switches:  
For single-SP systems, connect either FE port on SPA to one switch and either FE  
port on SP B to another switch port.  
Intel Storage System SSR212PP User Guide  
113  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
For dual-SP systems, connect either FE port on SP A to one switch and either FE  
port on SP B to another switch port.  
Customer-installable switches are easily configured, and some are preconfigured,  
to use ports 0 and 4 only for SP connections and ports 1-3 and 5-15 only for HBA  
connections. With switches set up in such "hard zones," you can connect FE 0 or  
FE 1 to ports 0 and 4 only, and connect HBAs only to ports 1—3 and 5—15.  
STEP 1. For each FE port that you want to connect to an HBA connector.  
a. Remove the protective covers from the FE connector on the SP and from one end of  
the optical cable, and plug the cable into the FE connector.  
b. Remove the protective covers from the optical connector on the HBA and from the  
free end of the optical cable and plug the cable into the HBA connector (Figure 54 or  
STEP 2. For each FE port that you want to connect to the switch:  
a. Remove the protective cover from the optical connector on the switch port that you  
will use and from one end of the optical cable, and plug the cable into the switch port  
b. Remove the protective covers from the FE connector on the SP and from the free end  
FE 0  
FE 1  
FE 0  
FE 1  
EMC3281  
FIGURE 54. SSR212PPf Front End (FE) and Optical Cable Connectors  
114  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
FE 0  
FE 1  
FE 0  
FE 1  
FE 0  
FE 0  
FE 1  
FE 1  
EMC3268  
FIGURE 55. SSR212PP2f Front End (FE) and Optical Cable Connectors  
STEP 3. For each switch port that you want to connect to the server:  
a. Remove the protective covers from the HBA port connector on the server and from  
one end of the optical cable, and plug the cable into the HBA connector.  
b. Remove the protective covers from the free end of the optical cable and from the  
lowest-numbered unused switch port (for hard—zoned switch ports 1-3, 5-15), and  
plug the cable into the switch port (Figure 56 or Figure 57).  
For a hard-zoned switch, you must use these ports in order from 1-3,  
To Server HBA  
To SP  
0
4
1
5
2
6
3
7
Switch  
O F F  
O
O F F  
O
I
I
!
O N  
O N  
0
4
1
5
2
6
3
7
O F F  
O N  
O F F  
O N  
O
O
I
I
EMC3288  
FIGURE 56. Sample Hard-zoned Switch Connections to an SSR212PPf Storage  
System  
Intel Storage System SSR212PP User Guide  
115  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
To Server HBA  
To SP A  
To SP B  
0
4
1
5
2
6
3
7
Switch  
O F F  
O
O F F  
O
I
I
!
O N  
O N  
0
4
1
5
2
6
3
7
O F F  
O N  
O F F  
O N  
O
O
I
I
EMC3289  
FIGURE 57. Sample Hard-zoned Switch Connections to an SSR212PP2f Storage  
System  
STEP 4. If the switch is not already powered up, power it up.  
116  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connecting iSCSI Ports to  
the Server  
22  
Connect iSCSI data ports on iSCSI storage systems directly to a server, or to an Ethernet  
LAN and connect the server iSCSI data ports to either a 10/100 or 1-gigabit Ethernet  
LAN, as described in this section.  
BeforeYou Start  
To complete this procedure, you will need:  
An Administrative Worksheet completed with your network administrator in  
Storage System Configuration," on page 15. The TCP/IP rules outlined in the "iSCSI  
Configuration Rules" section are crucial to a successful installation. For example,  
each NIC in a server directly connected to the storage system requires a separate  
subnet.  
One LAN cable per storage system iSCSI port that you will connect to the server or  
network. You can use CAT 5, CAT 5e, and CAT 6 LAN cables up to 100 meters to  
connect the storage-system iSCSI ports (labeled iSCSI-1000 on each SP) to an  
Ethernet port on a server.  
One LAN cable per server iSCSI port that you connect to the network. You need CAT  
5 LAN cables for iSCSI connections to 10/100 LANs or CAT 6 cables for iSCSI  
connections to 1-gigabit LANs. These cables can be up to 100 meters.  
STEP 1. For each iSCSI port on the storage system, connect one end of a LAN cable to the iSCSI 0  
or iSCSI 1 port on the SP and the other end:  
directly to a NIC or iSCSI HBA in a server (Figure 58 or Figure 59), or  
to a router or switch (Figure 60 or Figure 61) for network connections.  
STEP 2. For each NIC or iSCSI HBA port on the server, connect one end of a network cable (CAT  
6 for 1-gigabit Ethernet network, CAT 5 for 10/100 LAN) to the iSCSI port on the NIC or  
iSCSI HBA and the other end to the network (Figure 60 or Figure 61).  
Intel Storage System SSR212PP User Guide  
117  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
iSCSI Data  
LAN Cables  
SP A  
HBA  
HBA  
or NIC or NIC  
Server  
iSCSI Data Port  
EMC3310  
FIGURE 58. Connecting SSR212PPi iSCSI Ports Directly to a Server  
SP B  
iSCSI Data Port  
LAN Cables  
iSCSI Data  
HBA  
HBA  
HBA  
HBA  
or NIC or NIC  
or NIC or NIC  
SP A  
Server  
Server  
iSCSI Data Port  
FIGURE 59. Connecting SSR212PP2i iSCSI ports Directly to a Server  
EMC3309  
118  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Switch/Router  
iSCSI Data  
LAN Cables  
SP A  
HBA  
HBA  
or NIC or NIC  
Server  
iSCSI Data Port  
EMC3326  
FIGURE 60. Figure 36 Connecting the SSR212PPi and Server iSCSI Ports to a LAN  
SP B  
iSCSI Data Port  
Switch/Router  
LAN Cables  
iSCSI Data  
HBA  
HBA  
HBA  
HBA  
or NIC or NIC  
or NIC or NIC  
SP A  
Server  
Server  
iSCSI Data Port  
EMC3257  
FIGURE 61. Figure 37 Connecting the SSR212PP2i and Server iSCSI Ports to a  
LAN  
Intel Storage System SSR212PP User Guide  
119  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Conguring iSCSI Initiators for Linux or Windows  
Congurations without iSNS  
If you are using Windows with iSNS, this section is not for you. Instead, go to  
Before an iSCSI initiator can send data to or receive data from the storage system, you  
must configure the network parameters for the NIC orHBA iSCSI initiators to connect  
with the storage-system SP iSCSI targets.  
If the storage system already has NIC orHBA iSCSI initiators to connect with the storage-  
system SP iSCSI targets.  
Conguring Windows NIC Initiators to Connect to iSCSI Targets  
Use the Navisphere Server Utility to configure the network parameters for each NIC  
initiator that needs access to the storage system.  
The Microsoft iSCSI Initiator gives the same name to all NICs in a server. This  
name identifies the server, not the individual NICs, to a storage-system SP. This  
means that if multiple NICs from the same server are connected to an SP only one  
NIC is actually used. Other NICs are in standby mode. If you leave the Server  
Network Adapter IP option set to Default, the server will use one of the other NICs  
if the first NIC fails.  
STEP 1. On the server, open the Navisphere Server Utility. See Procedure 30, "Running the  
STEP 2. Select Congure iSCSI Connections on this server and click Next.  
STEP 3. Select Congure iSCSI Connections and click Next.  
STEP 4. In the iSCSI Targets and Connections window, select one of the following options to  
discover the iSCSI target ports on the connected storage systems:  
Discover iSCSI targets on this subnet scans the current subnet for all connected  
SSR212PP-Series iSCSI storage system targets. The utility scans the subnet in the  
range from 1 to 255. For example, if the current subnet is 10.12.77, the utility will  
scan the IP addresses from 10.12.77.1 to 10.12.77.255.  
If CHAP authentication is enabled on all target ports on a storage system,  
you cannot discover using a subnet scan. You must discover the targets using  
the target portal.  
Discover iSCSI targets for this target portal discovers targets known to the specified  
iSCSI SP data port.  
STEP 5. Click Next. If you entered the IP address of the iSCSI target and you have CHAP  
authentication enabled on that target, the CHAP login windows displays. Enter the CHAP  
security information (username and secret) and if you have mutual CHAP configured on  
120  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
the storage system and the server, check Mutual CHAP if you want mutual CHAP enabled  
on the initiator. Click Next.  
The utility scans for iSCSI target ports and displays the IP address for each target it  
discovers.  
STEP 6. In the iSCSI Targets window, select the IP address of the Inactive target.  
STEP 7. Under Login Options, do the following:  
Select Also login to peer iSCSI target for High Availability (recommended) if the peer  
iSCSI target is listed. This allows the utility to create a login connection to the peer  
target so if the target you selected above becomes unavailable, data would continue to  
the peer target.  
Leave the Server Network Adapter IP set to Default. This allows the iSCSI initiator to  
automatically failover to an available NIC in the event of a failure.  
If you are an advanced user and you want to control which network or subnet is  
used, you can select a Server Network adapter IP address from the drop-down list  
but failover may not occur.  
STEP 8. Click Logon to connect to the selected target. If CHAP authentication is enabled on the  
target, a CHAP login pop-up displays. Enter the CHAP security information (username  
and secret) and if you have mutual CHAP configured on the storage system and the server,  
check Mutual CHAP if you want mutual CHAP enabled on the initiator. Click OK.  
If you have previously logged in to this target, the CHAP login window may not  
display.  
STEP 9. Repeat STEP 8 for each target you want to login to.  
STEP 10. Click Next. The server registration window opens and lists all connected storage systems.  
STEP 11. In the server registration window, click Next to send the updated information to the  
storage system. A success message displays.  
STEP 12. Click Finish to close the wizard.  
Conguring Linux NIC Initiators to Connect to iSCSI Targets  
Each server connected to an iSCSI storage system must have a unique iSCSI  
initiator name for its iSCSI NICs. To determine a server s iSCSI initiator name for  
its NICs, use more/cat /etc/initiatorname.iscsi. Ifmultiple servers connected to the  
storage system have the same iSCSI initiator name, contact your Linux provider for  
help on making the names unique.  
Use the iSCSI driver bundled with the Linux kernel to configure the network parameters  
for each NIC that needs access to the storage system.  
Intel Storage System SSR212PP User Guide  
121  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CAUTION  
The Linux iSCSI driver gives the same name to all NICs in a server. This name  
identifies the server, not the individual NICs, to a storage-system SP. This means  
that if multiple NICs from the same server are connected to an SP only one NIC  
is actually used. Other NICs are in standby mode. The server will use one of the  
others if the first NIC fails.  
STEP 1. For an existing storage system with initiator CHAP already configured, stop the iSCSI  
service:  
/etc/init.d/iscsi stop  
STEP 2. Define a discovery address and other parameters in the iSCSI driver configuration file:  
a. Open the /etc/iscsi.conf file on your server with vi or another editor.  
b. Under Discovery Address Category, after the line  
#DiscoveryAddress=10.4.100.0,  
add a new, uncommented DiscoveryAddress= SP_port_ip_address line for each 1-Gbit  
iSCSI data port on each storage-system SP to which the NICs in that server have  
access. For SP_port_ip_address, use the data port addresses from section B on the  
Configuration," on page 15) that you completed. For example,  
#DiscoveryAddress=10.4.100.0  
DiscoveryAddress=172.31.1.100  
DiscoveryAddress=172.31.2.100  
Under Digest Settings , uncomment  
HeaderDigest=never  
DataDigest=never  
Under PORTAL FAILOVER SETTINGS, uncomment  
PortalFailover=no  
Under MULTIPATH SETTINGS, uncomment  
Multipath=yes  
Under LUN SETTINGS, uncomment  
LUNs=0-255  
Under SESSION TIMEOUT SETTINGS, uncomment the  
following parameter and change <number> to 10:  
DiskCommandTimout=10  
Under CONTINUOUS DISCOVERY SETTINGS, uncomment  
Continuous=yes  
Under iSCSI OPERATIONAL PARAMETER SETTINGS, uncomment  
InitialR2T=yes  
ImmediateData=yes  
Any other changes to the non-CHAP part of the configuration file are not supported.  
STEP 3. After you edit the configuration file, start the iSCSI service:  
/etc/init.d/iscsi start  
122  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To stop the iSCSI service, enter /etc/init.d/iscsi stop.  
STEP 4. Set the run levels for the iSCSI service to start automatically on reboot and shutdown:  
For Red Hat:  
chkcong - -level 345 iscsi on  
For SuSE:  
chkcong -s iscsi 345  
chkcong -s iscsi on  
Conguring HBA initiators to connect to iSCSI targets  
Use the QLogic SANsurfer software to configure the network parameters for each QLogic  
iSCSI HBA that needs to access the storage system.  
CAUTION  
You must not use the Microsoft iSCSI Software Initiator to control the QLogic  
iSCSI HBAs.  
STEP 1. Open QLogic SANsurfer as described in the QLogic documentation.  
STEP 2. For each iSCSI connection to the storage system:  
a. If multiple HBAs are listed in the first column under the server s name, select the  
HBA to be configured.  
b. Click the Target Settings tab.  
c. On the Target Settings page, click the green plus (+) sign and enter the IP address for  
the iSCSI port on your storage system, and then click OK.  
This address is the IP address of the iSCSI data port from Section B on the completed  
Administration Worksheet (page 20).  
The state for the port is No Connection Active.  
d. Select Auto Discover Targets.  
e. Click Save and Yes to save the changes and discover all targets.  
If the network is routed, the discovery finds all targets (ports) for the IP address you  
entered earlier. The state of routed ports is Session Active; for unrouted ports, it is  
Unknown.  
f. In the Security Check window, enter your password and click OK. The default  
password is cong.  
g. Select Cong Parameters.  
h. Select and enable all the targets that you want to connect to the server.  
If you do not want the server to connect to a port or you want to remove unknown  
ports, select the entry for the port and click the red minus (-) sign.  
Intel Storage System SSR212PP User Guide  
123  
Download from Www.Somanuals.com. All Manuals Search And Download.  
i. Enable timestamps, set the execution throttle to 256, and uncheck immediate data.  
j. Click Save and Yes.  
k. In the Security Check window, enter your password and click OK.  
The HBA performs an iSCSI discovery. Once finished, SANsurfer displays all of the  
targets on the storage system.  
Conguring the iSNS Client on the Storage System  
iSNS (Internet Storage Naming Service) is supported only for Windows iSCSI  
environments. iSNS provides the same function as the Simple Name Server (SNS) service  
in a Fibre Channel fabric - automated discovery, management, and configuration of iSCSI  
devices. It eliminates the need to manually configure each individual storage system with  
its own list of initiators and targets.  
iSNS includes an iSNS server component and iSNS client component. The iSNS server  
must reside somewhere within the IP storage network, for example, on a host or in the  
switch firmware. An iSNS client resides on both the iSCSI storage system and any iSCSI  
servers connected to the storage system. When you start the storage system, the iSNS  
client on the storage system gathers all the storage-system iSCSI port information and  
stores it locally on the storage system. When you add a server to the storage system s iSNS  
configuration, Navisphere Express establishes a connection from the storage system to the  
iSNS server, and then registers the information stored on the storage system with the iSNS  
server.  
STEP 2. For each iSNS server to which you want the storage system to connect:  
a. In the Manage iSCSI page, click iSNS to open the iSNS Servers page.  
b. Click Add to open the Add iSNS Servers dialog box.  
c. In the Add iSNS Servers dialog box, enter the IP address of the server you are adding.  
d. Click Apply to send the SP iSCSI port information to the server. Before the IP address  
is applied, it is tested to ensure it is valid.  
e. In the iSNS servers dialog box, select the server to be the primary server and click Set  
Primary.  
Conguring iSCSI Initiators for a Conguration With iSNS  
Before a NIC or iSCSI HBA iSCSI initiator in a server can send data to or receive data  
from the storage system, you must configure the network parameters for the initiators for  
iSNS.  
Conguring NIC initiators on Windows servers for iSNS  
Use the Navisphere Server Utility package to configure the network parameters for each  
NIC iSCSI initiator.  
124  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CAUTION  
The Microsoft iSCSI Initiator gives the same name to all NICs in a server. This  
name identifies the server, not the individual NICs, to a storage-system SP. This  
means that if multiple NICs from the same server are connected to an SP only  
one NIC is actually used. Other NICs are in standby mode. If you leave the  
Server Network Adapter IP option set to Default, the server will use one of the  
other NICs if the first NIC fails.  
STEP 1. On the server, open the Navisphere Server Utility.  
STEP 2. Select Congure iSCSI Connections on this server and click Next.  
STEP 3. Select Congure iSCSI Connections and click Next.  
STEP 4. In the iSCSI Targets and Connections window, select Discover iSCSI targets using this  
iSNS Server to discover the specified IP address of the iSNS SP port.  
STEP 5. Click Next.  
The utility scans for iSCSI target ports and displays the IP address for each target it  
discovers.  
STEP 6. In the iSCSI Targets window, select the IP address of the Inactive target.  
STEP 7. Under Login Options, do the following:  
a. Select Also login to peer iSCSI target for High Availability (recommended) if the peer  
iSCSI target is listed. This allows the utility to create a login connection to the peer  
target so if the target you selected above becomes unavailable, data would continue to  
the peer target.  
b. Leave the Server Network Adapter IP set to Default. This allows the iSCSI initiator to  
automatically failover to an available NIC in the event of a failure.  
If you are an advanced user and you want to control which network or subnet  
is used, you can select a Server Network adapter IP address from the drop-  
down list but failover may not occur.  
STEP 8. Click Logon to connect to the selected target.  
STEP 9. Repeat STEP 8 for each target you want to login to.  
STEP 10. Click Next. The server registration window opens and lists all connected storage systems.  
STEP 11. In the server registration window, click Next to send the updated information to the  
storage system. A success message displays.  
STEP 12. Click Finish to close the wizard.  
Intel Storage System SSR212PP User Guide  
125  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Conguring HBA initiators on Windows servers for iSNS  
Use the use QLogic SANsurfer package to configure the network parameters for each  
HBA iSCSI initiator  
STEP 1. Open QLogic SANsurfer as described in the QLogic documentation.  
STEP 2. In the HBA tree, select the HBA and click the HBA Options tab.  
The iSCSI name defaults to the iSCSI standard (iqn.xxxx).  
STEP 3. Select Enable iSNS.  
STEP 4. For each iSNS server, set the iSNS server address automatically or manually:  
For an automatic setting: Select Obtain iSNS server address automatically (via  
DCHP).  
For a manual setting: Select Use the following iSNS server address and enter the IP  
address of the server.  
STEP 5. Click Save to save the new settings.  
STEP 6. On the Target Settings tab, verify that the targets were discovered.  
If any target was not discovered, verify that the IP address for each iSNS server is correct  
and that iSNS is set up correctly on the server.  
126  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Registering the Server with  
the Storage System  
23  
If the storage system is connected to a Linux server, you must run the Navisphere Server  
Utility on each server connected to the storage system to register the server s HBAs with  
the storage system.  
If you are utilizing a Windows server and if you did not disable the Registration Service  
during the installation of the Server Utility (it is enabled by default), you do not need to  
run the Server Utility to register the server s HBAs with the storage system as described  
below. The registration happens automatically after the installation of the Server Utility.  
Start Navisphere Express and verify your HBA registration as described below.  
If you disabled the Registration Service during the installation of the Server Utility (it is  
enabled by default), you must run the Server Utility as described below, and then start  
Navisphere Express and verify your HBA registration.  
Running the Navisphere Server Utility on a Windows Server  
You need to run the Server Utility only if you disabled the Registration Service during the  
installation of the utility (it is enabled by default).  
STEP 1. Run the Navisphere Server Utility by clicking  
Start Programs EMC Navisphere Navisphere Server Utility.  
If the Server Utility does not discover the storage system, the storage system  
may still be rebooting. When the reboot is complete, the SP Boot/Fault light  
on the back of each SP is off and not blinking. If the reboot is complete, try  
running the utility again.  
STEP 2. Select your language, if prompted for it.  
STEP 3. In the Navisphere Server Utility dialog box, select Register this server to all connected  
storage systems.  
The utility automatically scans for all connected SSR212PP-Series storage systems and  
lists them under Connected Storage Systems. Locate the WWN of the HBA you just  
installed. The HBA should appear once for every SP port it is connected to.  
If the utility is already running, it does not automatically perform a scan, and  
you must click Rescan.  
STEP 4. Click Next to register the server with the storage system.  
Intel Storage System SSR212PP User Guide  
127  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
To each storage system, the utility sends the server s name and IP address. Once the server  
has storage on the storage system, the utility also sends the device name and volume or  
file system information for each virtual disk in the storage system that the server sees.  
STEP 5. Click Finish to exit the utility.  
Running the Navisphere Server Utility on a Linux Server  
STEP 1. On the server, run the utility by entering  
/opt/Navisphere/bin/naviserverutilcli  
If the Server Utility does not discover the storage system, the storage system may  
still be rebooting. When the reboot is complete, the SP Boot/Fault light on the back  
of each SP is off and not blinking. If the reboot is complete, try running the utility  
again.  
STEP 2. In the Server Utility, enter 1 to select Update Server Information. The utility automatically  
scans for connected SSR212PP-Series storage systems, and displays a list of the ones it  
finds.  
STEP 3. In the Server Utility, enter u to register the server with each storage system the utility  
found.  
The utility sends the server s name and IP address to each storage system. Once the server  
has storage on the storage system, the utility also sends the Linux or device name and  
volume or file system information for each virtual disk in the storage system that the  
server sees.  
STEP 4. Enter c (cancel) to stop the utility.  
Verifying HBA Registration  
STEP 2. In the Navisphere Express navigation pane, under Manage, click Connections to display  
the Manage Connections page.  
STEP 3. Verify that the SP/Port status is Active for each HBA, NIC or iSCSI HBA connected to the  
storage system.  
If the status is Active (unregistered), register the HBA, NIC or iSCSI HBA with the  
storage system by running the Navisphere Server Utility.  
If the status is Inactive, either the physical connection between the HBA, NIC or  
iSCSI HBA and the storage system is faulty or the storage system is not powered up.  
Go the "Troubleshoot" section on theSSR212PP support website or the SSR212PP-  
Series Documentation CD.  
128  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Conguring a New  
24  
Storage System  
Read this section if you are configuring a new storage system. A new storage system is  
one that was not already connected to a server when you started the installation procedure.  
BeforeYou Start  
STEP 2. Create a hot spare.  
A hot spare is a single global spare disk that serves as a temporary replacement for  
any failed disk in the storage system. The storage system automatically reconstructs  
data from the failed disk onto the hot spare, so the data is always available.  
In the Navisphere Express navigation pane, under Manage, click Hot Spare. For details on  
creating a hot spare, use the Navisphere Express Help Center.  
STEP 3. Create one or more disk pools on which to create virtual disks.  
A disk pool is a set of disks, all with the same capacity and redundancy, on which  
you create one or more virtual disks. A RAID 5 disk pool must include at least three  
disks and a RAID 1/0 must include at least two disks. The storage system supports  
a maximum of six disk pools.  
In the Navisphere Express navigation pane, under Manage, click Disk Pools. For details  
on creating a disk pool, use the Navisphere Express Help Center.  
For an SSR212PP2f (dual-SP) storage system, you should create at least two disk pools  
since the software assigns each disk pool you create to an SP as follows: disk pool 1 to SP  
A, disk pool 2 to SP B, disk pool 3 to SP A, and disk pool 4 to SP B. All the virtual disks  
you create on a disk pool are automatically assigned to the same SP as the disk pool, so if  
you create only one disk pool on the storage system, all virtual disks on the storage system  
are assigned to SP A and all data received or sent goes through SP A only.  
The disk modules marked 0 through 3 contain storage system software or reserved  
space according to their slot assignment. Do not move any disk marked 0 through 3  
from its assigned slot. Remove it only to replace the disk module. Part of the space  
Intel Storage System SSR212PP User Guide  
129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
on these disks is reserved or preloaded with system data, and as a result, is not  
available for your data. If you combine operating system disks in a disk pool with  
other disks, each of the other disks loses space for your data equal to the system  
data space on an operating system disk.  
STEP 4. Create one or more virtual disks on each disk pool.  
A virtual disk is a grouping of disk partitions into one span of disk storage space.  
Each virtual disk you create is distributed equally across the disks in the disk pool.  
A virtual disk looks like an individual disk to the server s operating system. Each  
disk pool supports 128 virtual disks.  
In the Navisphere Express navigation pane, under Manage, click Virtual Disks. For details  
on creating a virtual disk, use the Navisphere Express Help Center.  
If you want to connect additional servers to the storage system, you can create virtual  
disks for them now. You have to wait until the servers are connected and registered before  
you can assign these virtual disks to them.  
STEP 5. Assign one or more virtual disks to the server.  
To send data to or receive data from the virtual disks, you must assign the virtual  
disks to a server.  
In the Navisphere Express navigation pane, under Manage, click Virtual Disks. For details  
on assigning a virtual disk to a server, use the Navisphere Express Help Center.  
STEP 6. Verify that the virtual disks were assigned to the server by viewing the Manage Servers  
page.  
In the Navisphere Express navigation pane, under Manage, click Servers.  
You should see the virtual disks you assigned to the server listed in the Virtual Disks  
column of the server s row. If you do not see virtual disks, go the "Troubleshoot" section  
on the sSSR212PP support website or the SSR212PP-Series Documentation CD.  
STEP 7. Use the Event Notication page to configure the storage system to send an email message  
when it encounters a problem.  
In the Navisphere Express navigation pane, under System, click Settings, and then click  
Event Notication. For details on configuring the storage system to send email messages,  
use the Navisphere Express Help Center.  
STEP 8. On a Linux server,  
a. Make the virtual disks visible:  
For HBAs:  
rmmod driver_module  
modprobe driver_module (or insmod driver_module)  
where driver_module is the driver module name.  
130  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For NICs:  
/etc/init.d/PowerPath stop  
/etc /init.d/iscsi stop  
/etc /init.d/iscsi start  
/etc/ini.d/PowerPath start cat /proc/scsi/scsi  
b. Verify that all virtual disks have entries in the /proc/scsi/scsi file.  
If any disk entries are missing from the file:  
i. Use Navisphere Express to verify that each HBA is registered with the storage  
ii. Use Navisphere Express to verify that the virtual disks are connected to the server.  
In the Navisphere Express navigation pane, under Manage, click Virtual Disk to  
display the Manage Virtual Disks page.  
iii. Verify that each virtual disk is assigned to the appropriate server and the SP/Port  
status is Active for each HBA connected to the storage system.  
If a disk is not assigned to the appropriate server, double-click the disk, select  
Assign to Server and assign it to the appropriate server.  
If any virtual disk is still not connected to the server, go the "Troubleshoot"  
section on the SSR212PP support website or the SSR212PP-Series  
Documentation CD.  
STEP 9. Verify that each virtual disk is fully initialized:  
a. Start Navisphere Express on the storage system with the virtual disks. See  
b. In the Navisphere Express navigation pane under Manage, click Virtual Disk.  
c. In the Manage Virtual Disks screen, if the status of any virtual disk is Initializing, wait  
until the initialization is complete before continuing to the next section.  
STEP 10. If the virtual disk is connected to a server running Windows Server 2003, reboot the  
server.  
STEP 11. Verify that PowerPath sees all paths to the virtual disks.  
a. On the server, configure PowerPath:  
powermt cong  
b. On Windows 2003 Server hosts, start PowerPath iSCSI:  
i. Select Start Settings Control Panel.  
ii. On the Control Panel, do one of the following:  
Select Administrative Tools Computer Management, or  
^
^
Click the My Computer icon on your Desktop and select Manage from the  
menu.  
The PowerPath iSCSI application resides under the Storage component of the  
Computer Management utility.  
iii. On the Computer Management panel, select PowerPath iSCSI.  
iv. In the left pane, expand Disks.  
Intel Storage System SSR212PP User Guide  
131  
Download from Www.Somanuals.com. All Manuals Search And Download.  
v. Click on each virtual disk to display a list of :paths to the disk, and verify that all  
paths are listed. (Missing or failed paths do not, appear in the list of paths.)  
If a path is missing, refer to the "Troubleshoot" section on the SSR212PP  
support website or the SSR212PP2f-Series Documentation CD.  
c. For other Windows servers,  
i. On the Windows taskbar, either double-click the PowerPath Administrator icon or  
right-click the icon and select PowerPath Administrator.  
ii. In the results pane, verify that the path metric for each virtual disk is n/n where n  
is the total number of paths to the disk.  
d. For Linux servers, verify that PowerPath sees all the paths to the virtual disks with  
the PowerPath command:  
i. Configure PowerPath:  
powermt cong  
ii. Verify that PowerPath sees all the paths to the virtual disks with the PowerPath  
command:  
powermt display dev=all class=clariion  
132  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Conguring an Existing  
25  
Storage System  
Read this section if you are configuring an existing storage system. An existing storage  
system is one that was already connected to a server when you started the installation  
procedure.  
BeforeYou Start  
You will need the completed storage system disk information worksheet from  
STEP 2. If you need additional disk pools for virtual disks for the server, create one or more disk  
pools. In the Navisphere Express navigation pane, under Manage, click Disk Pools. For  
details on creating a disk pool, use the Navisphere Express Help Center.  
A disk pool is a set of disks, all with the same capacity and redundancy, on which  
you create one or more virtual disks. A RAID 5 disk pool must include at least three  
disks and a RAID 1/0 must include at least two disks. The storage system supports  
a maximum of six disk pools.  
The disk modules marked 0 through 3 contain storage system software or reserved  
space according to their slot assignment. Do not move any disk marked 0 through 3  
from its assigned slot. Remove it only to replace the disk module. Part of the space  
on these disks is reserved or preloaded with system data, and as a result, is not  
available for your data. If you combine operating system disks in a disk pool with  
other disks, each of the other disks loses space for your data equal to the system  
data space on an operating system disk.  
STEP 3. If you need additional virtual disks for the server, create one or more virtual disks on the  
disk pools. In the Navisphere Express navigation pane, under Manage, click Virtual Disks.  
For details on creating a virtual disk, use the Navisphere Express Help Center.  
Each disk pool supports 128 virtual disks.  
STEP 4. Assign one or more virtual disks to the server. Iin the Navisphere Express navigation  
pane, under Manage, click Virtual Disks. For details on assigning a virtual disk to a server,  
use the Navisphere Express Help Center.  
Intel Storage System SSR212PP User Guide  
133  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
To send data to or receive data from the virtual disks, you must assign the virtual  
disks to a server.  
STEP 5. Verify that the virtual disks were assigned to the server by looking at the Manage Servers  
page. In the Navisphere Express navigation pane, under Manage, click Servers.  
You should see the virtual disks you assigned to the server listed in the Virtual Disks  
column of the server s row.  
If you do not see virtual disks, go the "Troubleshoot" section on the SSR212PP support  
website or the SSR212PP-Series Documentation CD.  
STEP 6. On a Linux server, make the virtual disks visible:  
For NICs:  
/etc/init.d/PowerPath stop  
/etc /init.d/iscsi stop  
/etc /init.d/iscsi start  
/etc/ini.d/PowerPath start cat /proc/scsi/scsi  
For HBAs  
rmmod driver_module  
modprobe driver_module (or insmod driver_module)  
where driver_module is the driver module name  
STEP 7. On a Linux server, verify that all virtual disks have entries in the /proc/scsi/scsi directory  
and in the file for theHBAs in the /proc/scsi directory. If any disk entries are missing from  
the file:  
a. Use Navisphere Express to verify that each HBA is registered with the storage system:  
b. Use Navisphere Express to verify that the virtual disks are connected to the server:  
i. In the Navisphere Express navigation pane, under Manage, click Virtual Disk to  
display the Manage Virtual Disks page.  
ii. Verify that each virtual disk is assigned to the appropriate server and the SP/Port  
status is Active for each HBA connected to the storage system.  
If a disk is not assigned to the appropriate server, double-click the disk, select  
Assign to Server and assign it to the appropriate server.  
If any virtual disk is still not connected to the server, go the "Troubleshoot"  
section on the SSR212PP support website or the SSR212PP-Series  
Documentation CD.  
STEP 8. Verify that each virtual disk is fully initialized  
a. Start Navisphere Express on the storage system with the virtual disks.  
b. In the Navisphere Express navigation pane under Manage, click Virtual Disk.  
c. In the Manage Virtual Disks screen, if the status of any virtual disk is Initializing, wait  
until the initialization is complete before continuing to the next section.  
134  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
d. If the virtual disk is connected to a server running Windows Server 2003, reboot the  
server.  
STEP 9. Verify that PowerPath sees all paths to the virtual disks.  
a. Configure PowerPath:  
powermt cong  
b. On Windows 2003 Server hosts:  
i. Select Start Settings Control Panel.  
ii. On the Control Panel, do one of the following:  
¥SelectAdministrative Tools Computer Management, or  
¥Click theMy Computer icon on your Desktop and select Manage from the menu.  
The PowerPath iSCSI application resides under the Storage component of the  
Computer Management utility.  
iii. On the Computer Management panel, select PowerPath iSCSI.  
iv. In the left pane, expand Disks.  
v. Click on each virtual disk to display a list of :paths to the disk, and verify that all  
paths are listed. (Missing or failed paths do not, appear in the list of paths.)  
If a path is missing, refer to the "Troubleshoot" section on the SSR212PP  
support website or the SSR212PP2f-Series Documentation CD.  
c. On other Windows servers:  
i. On the Windows taskbar, either double-click the PowerPath Administrator icon or  
right-click the icon and select PowerPath Administrator.  
ii. In the results pane, verify that the path metric for each virtual disk is n/n where n  
is the total number of paths to the disk.  
d. On Linux servers: enter the following command:  
i. Configure PowerPath:  
powermt cong  
ii. Verify that PowerPath sees all the paths to the virtual disks with the PowerPath  
command:  
powermt display dev=all class=clariion  
Intel Storage System SSR212PP User Guide  
135  
Download from Www.Somanuals.com. All Manuals Search And Download.  
136  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting up CHAP Security for  
iSCSI Storage Systems  
26  
Challenge Handshake Authentication Protocol (CHAP) is a method of authenticating  
iSCSI users. The iSCSI storage system can use CHAP to authenticate initiators and  
initiators can likewise authenticate targets such as the storage system.  
CAUTION  
If you do not configure CHAP security for the storage system, any host  
connected to the same IP network as the storage-system iSCSI ports can read  
from and write to the storage system. If the storage system is on a private  
network, you can choose not to use CHAP security. If the storage system is on a  
public network, we strongly recommend that you use CHAP security.  
If you want to use CHAP security, you should set up and enable it on the storage  
system before preparing virtual disks to receive data. If you prepare disks to receive  
data before you set up and enable CHAP security, you lose visibility to the disks.  
CHAP has two variants:  
Initiator CHAP sets up accounts that iSCSI initiators use to connect to targets. The  
target authenticates the initiator. Initiator CHAP is the primary CHAP authentication  
method.  
Navisphere Express provides Basic and Advanced initiator CHAP options. Basic  
CHAP specifies one secret (password) for all initiators that log in to a given target.  
The Advanced option allows you to specify a different secret for each initiator, and  
also allows you to set up Mutual CHAP.  
Mutual CHAP is applied in addition to advanced initiator CHAP, mutual CHAP sets  
up an account that a target uses to connect to an initiator. The initiator authenticates  
the target.  
Setting up and enabling initiator CHAP is necessary for iSCSI security to work. Mutual  
CHAP is an optional additional level of security. Only one mutual CHAP credential is  
supported for each storage system.  
The following steps are necessary to set up initiator CHAP:  
On a server that uses NICs or iSCSI HBAs, log off and remove target portals.  
On the storage system, configure and enable initiator CHAP (basic or advanced) by  
entering the initiator user data for all initiators that are allowed to access the storage  
system.  
If you are setting up the optional mutual CHAP, you must enter the mutual CHAP user  
data on each server; that is, the target user account data that the storage system sends  
to initiators. The initiators compare this data with their stored user data when they  
authenticate the storage system.  
Intel Storage System SSR212PP User Guide  
137  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
To set up mutual CHAP you must first configure advanced initiator CHAP.  
On each server that will use the storage system, configure initiator CHAP by entering  
the user data for each initiator that will connect to the target. The initiator sends this  
data to the target and the target uses this data to authenticate the initiator.  
On each server, ensure that the target is logged in to the initiators.ensure that the  
session is active, and that HBAs are logged in to the target.  
After you decide on the security level you want to configure in your SSR212PP2f-Series  
environment, follow the instructions in either the section on setting up basic or advanced  
CHAP the NICs or iSCSI HBAs.  
BeforeYou Start  
Make sure that you complete the CHAP worksheets in Procedure 3, "Planning Your iSCSI  
Storage System Configuration," on page 15, and that you have the worksheets available.  
If your system utilizes QLogic iSCSI HBAs, refer to the QLogic documentation supplied  
with the HBA for more information. Note that QLogic uses the following terminology:  
EMC terminology  
CHAP Username  
CHAP Secret  
QLogic terminology  
Initiator Name  
Initiator Secret  
CHAP  
Initiator (Basic) CHAP  
Removing iSCSI Targets  
STEP 1. On a Windows server without iSNS: log off and remove targets:  
When you remove an iSCSI target, the specified target and all other targets on the  
storage system will be removed. If you want to remove a specific target port and  
not all targets on the storage system, you must use the Microsoft Software Initiator.  
a. On the server that includes your iSCSI initiators, open the Navisphere Server Utility.  
b. Log off and remove any targets with the storage system you are setting up for CHAP:  
i. Select Congure iSCSI Connections on this server and then Congure iSCSI  
Connections.  
ii. In the iSCSI Targets and Connections window, under View iSCSI Connections,  
select View currently available targets.  
iii. Click Next. The utility scans for target ports and displays the IP address for each  
target it discovers.  
iv. In the iSCSI Targets window, select the IP address of the Connected target and  
click Logoff. The target status changes to Inactive.  
138  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
v. Select the IP address of the Inactive target and click Remove. All targets for the  
storage system are removed.  
vi. Click Cancel to close the wizard.  
STEP 2. On a Windows server with iSNS, log off and remove targets:  
a. On the server that includes your iSCSI initiators, open the Microsoft iSCSI Software  
Initiator.  
b. Log off any connected targets you are setting up for CHAP:  
i. On the Targets tab, click Details and log off all targets.  
ii. On the Persistent Targets tab, remove any persistent targets.  
Setting Up Basic Initiator CHAP on the Storage System  
With basic CHAP security, the storage systemuses the same username and secret to  
authenticate all host initiators. CHAP credentials are configured for the entire storage  
system, and are required for CHAP security.  
STEP 1. On your storage system management station, start Navisphere Express on the storage  
STEP 2. In the Navisphere Express navigation pane, under Manage, click iSCSI to open the  
Manage iSCSI screen.  
STEP 3. To set basic security, click Basic.  
STEP 4. In the iSCSI Security - Basic screen, click Initiator CHAP Conguration.  
STEP 5. In the Initiator CHAP Conguration - Basic screen, click Add. The Add Initiator CHAP  
Credentials - Basic screen opens.  
STEP 6. In Step 1 on the screen, enter a CHAP username. This name must match the username for  
the server s iSCSI initiators.  
STEP 7. In Step 2 on the screen, enter and confirm a CHAP secret.  
You will enter this secret on the server later.  
You can specify the secret in ASCII or hexadecimal characters. ASCII secrets must consist  
of at least 12 and no more than 16 characters. Hexadecimal secrets must consist of at least  
12 and no more than 16 pairs of data (24 to 32 characters). If you specify the CHAP secret  
using hexadecimal characters, you must select CHAP Secret Specied In Hex.  
STEP 8. In Step 3 on the screen, click Apply to add the CHAP credential and return to the Add  
Initiator CHAP Credentials - Basic screen.  
STEP 9. Click View all initiator CHAP credentials and confirm that the new CHAP entry exists.  
Intel Storage System SSR212PP User Guide  
139  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STEP 10. Enable basic CHAP on the storage system  
a. Open Navisphere Express on the storage system you are configuring. See  
b. In the Navisphere Express navigation pane, under Manage, click iSCSI to open the  
Manage iSCSI screen.  
c. Under Security, click Basic.  
d. In the iSCSI Security - Basic screen, click Enable.  
Setting up Advanced Initiator CHAP on the Storage System  
Advanced CHAP security lets you set the same username and secret for all host initiators  
(basic CHAP), or set different usernames and secrets for each host initiator. It also allows  
you to restrict authentication to specific host initiators (IQNs), and to set up optional  
mutual CHAP.  
STEP 1. On the Windows server that includes your iSCSI initiators, log off and remove iSCSI  
targets following the instructions given in "Removing iSCSI Targets" on page 138.  
STEP 2. On your storage system management station, start Navisphere Express on the storage  
STEP 3. In the Navisphere Express navigation pane, under Manage, click iSCSI to open the  
Manage iSCSI screen.  
STEP 4. To set advanced security, click Advanced.  
STEP 5. In the iSCSI Security - Advanced screen, click Initiator CHAP Conguration.  
STEP 6. In the Initiator CHAP Conguration - Advanced screen, click Add.  
The Add Initiator CHAP Credentials - Advanced screen opens.  
STEP 7. In Step 1 on the screen, select the initiator or initiators that will use the new CHAP  
credentials.  
You can allow any initiator to log in with the credentials you specify, (the equivalent of  
basic CHAP), or you can restrict access to a specific initiator. To restrict access, you must  
create a CHAP user for each server initiator.  
STEP 8. In Step 2 on the screen, enter a CHAP username. This name must match whatever is  
entered as a username for the server.  
You can manually enter a username, or, if logins are restricted to specific initiators  
(STEP 7), you can choose to use the initiator name (IQN) as the CHAP user.  
STEP 9. In Step 3 on the screen, enter and confirm a CHAP secret.  
140  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
You will also enter this secret for the server initiators.  
You can specify the secret in ASCII or hexadecimal characters. ASCII secrets must consist  
of at least 12 and no more than 16 characters. Hexadecimal secrets must consist of at least  
12 and no more than 16 pairs of data (24 to 32 characters). If you specify the CHAP secret  
using hexadecimal characters, you must select CHAP Secret Specied In Hex.  
STEP 10. In Step 4 on the screen, either click Apply to set the advanced initiator CHAP credentials  
or click Cancel to return to the Initiator CHAP Conguration - Advanced screen.  
STEP 11. Click View all initiator CHAP credentials and confirm that the new CHAP entry exists.  
Setting up Mutual Initiator CHAP on the Storage System  
For optional mutual initiator CHAP, you enter the mutual CHAP username and secret that  
you entered on each target on each initiator as well. If mutual CHAP is enabled, the target  
sends its username and secret when it responds to the initiator. When the target sends this  
data, the initiator compares it with an account database and authenticates the target.  
STEP 1. On the Windows server that includes your iSCSI initiators, log off and remove iSCSI  
targets following the instructions given in "Removing iSCSI Targets" on page 138.  
STEP 2. On your storage system management station, start Navisphere Express on the storage  
STEP 3. In the Navisphere Express navigation pane, under Manage, click iSCSI.  
The Manage iSCSI screen opens.  
STEP 4. Click Advanced.  
STEP 5. In the iSCSI Security - Advanced screen, click Mutual CHAP Conguration.  
STEP 6. In the Mutual CHAP Conguration - Advanced screen, click Add.  
The Add Mutual CHAP Credentials - Advanced screen opens.  
STEP 7. In Step 1 on the screen, enter a CHAP username for the storage system.  
STEP 8. In Step 2 on the screen, enter a CHAP secret that is not the same as any storage-system  
initiator secret you specified, and confirm the secret.  
You can specify the secret in ASCII or hexadecimal characters. ASCII secrets must consist  
of at least 12 and no more than 16 characters. Hexadecimal secrets must consist of at least  
12 and no more than 16 pairs of data (24 to 32 characters). If you specify the CHAP secret  
using hexadecimal characters, you must select CHAP Secret Specified in Hex.  
STEP 9. In Step 3 on the screen, click Apply to add the CHAP credential and return to the Mutual  
CHAP Conguration - Advanced screen.  
Intel Storage System SSR212PP User Guide  
141  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STEP 10. Click View mutual CHAP credentials and confirm that the new CHAP entry exists.  
STEP 11. Enable advanced CHAP on the storage system:  
a. In the Navisphere Express navigation pane, under Manage, click iSCSI to open the  
Manage iSCSI screen.  
b. Under Security, click Advanced.  
c. In the iSCSI Security - Advanced screen, click Enable.  
Conguring Basic Chap on a Windows Server with NICs  
CAUTION  
CHAP security must be enabled on the storage systembefore using the Configure  
iSCSI connections on the Server Utility.  
After entering CHAP data on the target, you must enter the same data on each NIC  
initiator you log on to. On each initiator, you enter the initiator CHAP user account data  
(username and secret) that the initiator sends to the target for authentication. For basic  
initiator CHAP, this data is the initiator username and secret that you entered on the target.  
When the initiator sends this data, the target compares it with an account database and  
authenticates the initiator.  
STEP 1. Log off and remove iSCSI targets using the instructions in "Removing iSCSI Targets" on  
STEP 2. On the server, open the Navisphere Server Utility. See Procedure 30, "Running the  
STEP 3. Select Congure iSCSI Connections on this server and click Next.  
STEP 4. Select Congure iSCSI Connections and click Next.  
STEP 5. In the iSCSI Targets and Connections window, select one of the following options to  
discover the iSCSI target ports on the connected storage systems:  
Discover iSCSI targets on this subnet scans the current subnet for all connected  
SSR212PP2f-Series iSCSI storage system targets. The utility scans the subnet in the  
range from 1 to 255. For example, if the current subnet is 10.12.77, the utility will  
scan the IP addresses from 10.12.77.1 to 10.12.77.255.  
If CHAP authentication is enabled on all target ports on a storage system, you  
cannot discover using a subnet scan. You must discover the targets using the target  
portal.  
Discover iSCSI targets for this target portal discovers targets known to the specified  
iSCSI SP data port.  
142  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Discover iSCSI targets using this iSNS Server discovers the specified IP address of  
the iSNS server.  
STEP 6. Click Next. If you entered the IP address of the iSCSI target and you have CHAP  
authentication enabled on that target, the CHAP login windows displays. Enter the CHAP  
security information (username and secret) and if you have mutual CHAP configured on  
the storage system and the server, check Mutual CHAP if you want mutual CHAP enabled  
on the initiator. Click Next.  
STEP 7. The utility scans for iSCSI target ports and displays the IP address for each target it  
discovers.  
STEP 8. In the iSCSI Targets window, select the IP address of the Inactive target.  
STEP 9. Under Login Options, do the following:  
Select Also login to peer iSCSI target for High Availability (recommended) if the peer  
iSCSI target is listed. This allows the utility to create a login connection to the peer  
target so if the target you selected above becomes unavailable, data would continue to  
the peer target.  
Leave the Server Network Adapter IP set to Default. This allows the iSCSI initiator to  
automatically failover to an available NIC in the event of a failure.  
If you are an advanced user and you want to control which network or subnet is  
used, you can select a Server Network adapter IP address from the drop-down list  
but failover may not occur.  
STEP 10. Click Logon to connect to the selected target. If CHAP authentication is enabled on the  
target, a CHAP login pop-up displays. Enter the CHAP security information (username  
and secret) and if you have mutual CHAP configured on the storage system and the server,  
check Mutual CHAP if you want mutual CHAP enabled on the initiator. Click OK.  
STEP 11. Repeat STEP 10 for each target you want to login to.  
STEP 12. Click Next. The server registration window opens and lists all connected storage systems.  
STEP 13. In the server registration window, click Next to send the updated information to the  
storage system. A success message displays.  
STEP 14. Click Finish to close the wizard. You have set and enabled basic security on the server and  
storage system.  
Intel Storage System SSR212PP User Guide  
143  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Conguring Basic Chap on a Linux Server with NICs  
CAUTION  
CHAP security must be enabled on the storage systembefore using the Configure  
iSCSI connections on the Server Utility.  
After entering CHAP data on the target, you must enter the same data on each NIC  
initiator. On each initiator, you enter the initiator CHAP user account data (username and  
secret) that the initiator sends to the target for authentication. For basic initiator CHAP,  
this data is the initiator username and secret that you entered on the target. When the  
initiator sends this data, the target compares it with an account database and authenticates  
the initiator.  
STEP 1. Start the Linux iSCSI driver by typing /etc/init.d/iscsi start.  
STEP 2. Based on the security model you want to build for security, follow the examples in the  
/etc/iscsi.conf configuration file to define usernames and passwords.  
STEP 3. Find the driver parameter models you want to use, and configure them as shown in the  
examples in configuration file.  
For more configuration information and examples, see the README file in the  
source directory.  
The following excerpt from the iscsi.conf configuration file shows two sections of the file:  
the Authentication Settings section and the Target Name Specific Settings section. The  
Authentication Settings section shows an authenticated configuration using CHAP. The  
Target Name Specific Settings section shows a non-authenticated configuration.  
Your version of iscsi.conf may be different from the file shown below. This  
example shows some configuration guidelines.  
# iSCSI configuration file - see iscsi.conf(5)  
# Authentication Settings  
# ----------------------- #  
# You may configure a default Username and Password to  
use for CHAP  
# authentication by specifying the Global username and  
password parameters  
# in the format as mentioned below. These entries will  
need to precede any  
# "DiscoveryAddress" entries if authentication needs to  
be enabled for all the  
# iSCSI targets.  
#
# Example:  
#
# Username=john  
144  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
# Password=welcome  
# or  
# OutgoingUsername=john  
# OutgoingPassword=welcome  
#
# The "OutgoingUsername" will specify the username to  
be sent to the target  
# for login authentication. The "OutgoingPassword" is  
the CHAP secret password  
# to be used when sending challenge responses to the  
target.  
#
# You may configure CHAP authentication settings that  
will apply to every  
# target discovered at a particular address by adding  
"OutgoingUsername=u"  
# and "OutgoingPassword=p" entries indented below the  
"DiscoveryAddress"  
# entry they apply to.  
#
# Example:  
#DiscoveryAddres=127.0.0.1 (Storage System1 SPA)  
# Username=john  
# Password=welcome  
#DiscoveryAddres=127.0.0.2 (Storage System1 SPB)  
# Username=betty  
# Password=bienvenue  
#
# or  
#DiscoveryAddress=127.0.0.1 (Storage System1 SPA)  
#DiscoveryAddress=127.0.0.2 (Storage System1 SPB)  
#DiscoveryAddress=127.0.00.1 (Storage System2 SPA)  
#DiscoveryAddress=127.0.00.2 (Storage System2 SPB)  
# Username=john  
# Password=welcome  
#DiscoveryAddres=127.0.0.3 (Storage System3 SPA)  
#DiscoveryAddres=127.0.00.3 (Storage System3 SPB)  
# Username=betty  
# Password=bienvenue  
#
# You can configure 2 WAY authentication to enable the  
authentication of the  
# initiator by the target and vice-versa. The "Outgoing  
Username" and "Outgoing  
# Password" fields specify the initiator authentication  
and "IncomingUsername"  
# and "IncomingPassword" can be used for target  
authentication.  
#
# The "IncomingUsername" will specify  
must be received from  
# target if login authentication occurs.  
"IncomingPassword" is the CHAP  
# secret to be used when verifying challenge  
from the target.  
# The "OutgoingPassword" and "IncomingPassword"  
should be unique.  
#
# Example:  
#
# OutgoingUsername=alice  
# OutgoingPassword=foo  
#
# IncomingUsername=alice3  
Intel Storage System SSR212PP User Guide  
145  
Download from Www.Somanuals.com. All Manuals Search And Download.  
# IncomingPassword=foo  
# TargetName Specific Settings  
# ----------------------------  
# Target-specific settings should be entered  
respective "TargetName"  
# entries. If Multipath is enabled, then  
target-specific settings will be  
# be applicable for all iSCSI sessions  
#
# If settings under "Subnet" entry are  
settings under  
# "TargetName" entry, the settings under  
be considered.  
#
#TargetName=iqn.1987-05.com.cisco:00.0d1d898e8d66.  
#
# The TargetName Settings can have the  
specific to a target.  
#
# 1) CRC Settings # 2) iSCSI Operational  
settings  
# 3) Connection Timeout Settings  
# 4) Session Timeout Settings  
# 5) Error Handling Timeout Settings  
# 6) TCP Settings  
# 7) Portal Failover Settings  
# 8) Multipath Settings  
# 9) LUN settings  
# 10) PreferredSubnet and PreferredPortal  
# NOTES:  
# ------  
# If any of the configuration parameters  
mentioned under Configuration  
# type DiscoveryAddress, TargetName or  
values will be  
# considered if they are specified, else  
settings will apply for these  
# configuration parameters.  
#
# All entries specified below any of the  
types must be indented  
# by a whitespace character or a tab to  
local to a category. If  
# they are specified in the 1st column  
default considered as global  
#
# Example: # #Subnet=127.0.0.1 # ActiveTimeout=10  
# PingTimeout=10  
# LoginTimeout=30  
#
# In the above case LoginTimeout is considered a global  
value and will have  
# scope until another LoginTimeout entry is specified.  
# If there are conflicting entries for the same target  
through the Subnet and  
# TargetName or DiscoveryAddress entries, the Subnet  
entries in the file will  
# take precedence.  
#
# Example:  
#
#Subnet=127.0.0.1 # ActiveTimeout=10  
#
#TargetName=iqn.1987-05.com.cisco:00.0d1d898e8d66.t0  
146  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
# ActiveTimeout=15  
#
# In the above scenario, the Subnet specific setting  
will take effect.  
# If there is any conflict between DiscoveryAddress  
and Global entries,  
# DiscoveryAddress settings takes precedence.  
#
#Username=bob  
#Password=bob123  
# DiscoveryAddress=127.0.0.1  
# Username=  
# Password= DiscoveryAddress=127.0.0.2  
# Username=  
# Password= DiscoveryAddress=127.0.0.3  
# Username=  
# Password= DiscoveryAddress=127.0.0.4  
# Username=  
# Password=  
# DiscoveryAddress=127.0.0.5  
# Username=  
# Password= DiscoveryAddress=127.0.0.6  
# Username=  
# Password=  
# In the above case, the DiscoveryAddress settings  
will be considered.  
# Targets without any matching Subnet, TargetName or  
DiscoveryAddress entries  
# will take the global values if any in the config file,  
else the default  
# values will take effect.  
#
# Example:  
#
#HeaderDigest=prefer-on  
#DataDigest=prefer-on  
#InitialR2T=No #ActiveTimeout=10  
#
# If there are any duplicate entries for a configuration  
parameter in the conf  
# file the latest entry in the file will take effect.  
#
# Example:  
#
# IncomingUsername=alice  
# IncomingPassword=alice123  
#multipath=no  
#LUNs=0-255  
# IncomingUsername=bob  
# IncomingPassword=bob123  
#
# In the above case, IncomingUsername will be "bob"  
and IncomingPassword will  
# be "bob123".  
#
When you have configured basic CHAP for each NIC initiator in the server, you have set  
and enabled basic security on the server and storage system.  
STEP 4. Restart the iSCSI service:  
/etc/init.d/iscsi stop  
Intel Storage System SSR212PP User Guide  
147  
Download from Www.Somanuals.com. All Manuals Search And Download.  
/etc/init.d/iscsi start  
STEP 5. Run the Navisphere Server Utility to update the storage system with the server  
information.  
Conguring Basic CHAP on a Server with iSCSI HBAs  
Configure basic initiator CHAP on each iSCSI HBA that communicates with the server:  
STEP 1. Open the SANsurfer software.  
STEP 2. Click the Target Settings tab.  
STEP 3. Click Cong Authentication on the bottom of the pane.  
The default password is config.  
STEP 4. Select the CHAP tab.  
STEP 5. Under Initiator Name and Secret:  
a. Click Enable for your target IP.  
b. Select Set default initiator name and secret.  
c. Type in the initiator name for your HBA initiator. This name must match the username  
for the storage system.  
d. Type in the secret that you configured in Navisphere Express.  
The Initiator Name and Initiator Secret fields in the middle window display  
will populate automatically.  
e. Click OK.  
STEP 6. Save your changes on the Target Settings window; (the default password remains config).  
STEP 7. Verify that your session remains active.  
148  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Conguring Advanced or Mutual CHAP on a Windows Server  
with NICs  
CAUTION  
CHAP security must be enabled on the storage systembefore using the Configure  
iSCSI connections on the Server Utility.  
After entering CHAP data on the target, you must enter the same data on each NIC  
initiatoryou log on to. On each initiator, you enter the initiator CHAP user account data  
(username and secret) that the initiator sends to the target for authentication. This data is  
one of the initiator usernames and secrets that you entered on the target. When the initiator  
sends this data, the target compares it with an account database and authenticates the  
initiator.  
STEP 1. On a Windows server, open the Navisphere Server Utility. See Procedure 30, "Running the  
STEP 2. Select Congure iSCSI Connections on this server and click Next.  
STEP 3. If you are setting up mutual CHAP, follow the steps below.  
If you are not setting up mutual CHAP, go to STEP 4.  
a. Select Congure Mutual CHAP and click Next.  
b. In the Mutual CHAP Authentication window, enter the mutual CHAP secret  
(password). If you have already configuredmutual CHAP on the storage system, enter  
the same secret. Click Next.  
You entered the mutual CHAP secret in the Add Initiator CHAP Credentials -  
Advanced page.  
c. Click Finish in the success window.  
STEP 4. Select Congure iSCSI Connections and click Next.  
STEP 5. In the iSCSI Targets and Connections window, select one of the following options to  
discover the iSCSI target ports on the connected storage systems:  
Discover iSCSI targets on this subnet scans the current subnet for all connected  
SSR212PP2f-Series iSCSI storage system targets. The utility scans the subnet in the  
range from 1 to 255. For example, if the current subnet is 10.12.77, the utility will  
scan the IP addresses from 10.12.77.1 to 10.12.77.255.  
Intel Storage System SSR212PP User Guide  
149  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
If CHAP authentication is enabled on all target ports on a storage system,  
you cannot discover using a subnet scan. You must discover the targets using  
the target portal.  
Discover iSCSI targets for this target portal discovers targets known to the specified  
iSCSI SP data port.  
Discover iSCSI targets using this iSNS Server discovers the specified IP address of  
the iSNS server.  
STEP 6. Click Next. If you entered the IP address of the iSCSI target and you have CHAP  
authentication enabled on that target, the CHAP login windows displays. Enter the CHAP  
security information (username and secret) and if you have mutual CHAP configured on  
the storage system and the server, check Mutual CHAP if you want mutual CHAP enabled  
on the initiator. Click Next.  
The utility scans for iSCSI target ports and displays the IP address for each target it  
discovers.  
STEP 7. In the iSCSI Targets window, select the IP address of the Inactive target.  
STEP 8. Under Login Options, do the following:  
Select Also login to peer iSCSI target for High Availability (recommended) if the peer  
iSCSI target is listed. This allows the utility to create a login connection to the peer  
target so if the target you selected above becomes unavailable, data would continue to  
the peer target.  
Leave the Server Network Adapter IP set to Default. This allows the iSCSI initiator to  
automatically failover to an available NIC in the event of a failure.  
If you are an advanced user and you want to control which network or subnet is  
used, you can select a Server Network adapter IP address from the drop-down list  
but failover may not occur.  
STEP 9. Click Logon to connect to the selected target. If CHAP authentication is enabled on the  
target, a CHAP login pop-up displays. Enter the CHAP security information (username  
and secret) and if you have mutual CHAP configured on the storage system and the server,  
check Mutual CHAP if you want mutual CHAP enabled on the initiator. Click OK.  
STEP 10. Repeat STEP 9 for each target you want to login to.  
STEP 11. Click Next. The server registration window opens and lists all connected storage systems.  
STEP 12. In the server registration window, click Next to send the updated information to the  
storage system. A success message displays.  
STEP 13. Click Finish to close the wizard. You have set and enabled basic security on the server and  
storage system.  
You have completed the setup and enabling of advanced security on the server and storage  
system.  
150  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Conguring Advanced or Mutual CHAP on a Server with iSCSI  
HBAs  
STEP 1. Open the SANsurfer software.  
STEP 2. Select the Target Settings tab.  
STEP 3. Select Cong Authentication from the bottom of the pane, and in the password prompt, use  
the password cong.  
STEP 4. Select the CHAP tab.  
STEP 5. Under Initiator Name and Secret:  
a. Click Enable for your target IP.  
b. If you are configuring mutual CHAP, select Bidi (bi-directional).  
c. Select Set default initiator name and secret.  
d. Type in the initiator name for your HBA initiator.  
e. Type in the secret that you configured in Navisphere Express.  
The Initiator Name and Initiator Secret fields in the middle window display will  
populate automatically.  
f. If you are configuring mutual CHAP:  
i. Click the green plus sign (+) on the right of the Target Table portion of the CHAP  
screen.  
ii. Double-click the blank row in the Target Name column, and enter the target  
CHAP username that you entered on the storage system.  
iii. Double-click the row in the Target Secret column, and enter the target CHAP  
secret that you entered on the storage system.  
g. Click OK.  
STEP 6. Save your changes on the Target Settings screen (the default password remains cong).  
STEP 7. Confirm that your session remains active.  
Intel Storage System SSR212PP User Guide  
151  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Conguring Advanced or Mutual CHAP on a Linux Server  
with NICs  
CAUTION  
CHAP security must be enabled on the storage systembefore using the Configure  
iSCSI connections on the Server Utility.  
After entering CHAP data on the target, you must enter the same data for the NIC  
initiators.  
STEP 1. Open the /etc/iscsi.conf file on your server with vi or another editor.  
STEP 2. For each NIC initiator in the server, enter the initiator CHAP user account data (username  
and secret) that the initiator sends to the target for authentication.  
This data is one of the initiator usernames and secrets that you entered on the target. When  
the initiator sends this data, the target compares it with an account database and  
authenticates the initiator.  
The following example in the Authentication Settings section of the iscsi.conf file shows  
advanced CHAP.  
Username=john  
Password=welcome  
# or  
OutgoingUsername=john  
OutgoingPassword=welcome  
The following example in the Authentication Settings section of the iscsi.conf file shows  
advanced CHAP, which lets you set different usernames and secrets for each host initiator.  
The first part shows one storage system; each SP has a different username and password.  
The second part shows three storage systems; two use one username and password, and  
the third uses a different username and password.  
DiscoveryAddres=127.0.0.1 (Storage System1 SPA)  
Username=john  
Password=welcome  
DiscoveryAddres=127.0.0.2 (Storage System1 SPB)  
Username=betty  
Password=bienvenue  
#
# or  
DiscoveryAddress=127.0.0.1 (Storage System1 SPA)  
DiscoveryAddress=127.0.0.2 (Storage System1 SPB)  
DiscoveryAddress=127.0.0.3 (Storage System2 SPA)  
DiscoveryAddress=127.0.0.4 (Storage System2 SPB)  
Username=john  
Password=welcome  
DiscoveryAddress=127.0.0.5 (Storage System3 SPA)  
DiscoveryAddress=127.0.0.6 (Storage System3 SPB)  
152  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Username=betty  
Password=bienvenue  
When you have configured advanced CHAP for each NIC initiator in the server, you have  
completed the setup and enabling of advanced security on the server and storage system.  
STEP 3. Restart the iSCSI service:  
/etc/init.d/iscsi stop  
/etc/init.d/iscsi start  
STEP 4. Run the Navisphere Server Utility to update the storage system with the server  
Adding NIC or iSCSI HBA Initiators to the CHAP Conguration  
If the storage system is already configured for advanced CHAP with a unique secret for  
each NIC or iSCSI HBA initiator and you are either adding a new server to the storage  
system or a new NIC or iSCSI HBA to a server already connected to the storage system,  
you need to add the NIC or iSCSI HBA initiator information to the storage system s  
CHAP configuration.  
If you set up basic CHAP for the storage system either through the Navisphere Express  
Basic screen or through the Navisphere Express Advanced screen by allowing any  
initiator to logon with the secret, you do not need to change the storage-system CHAP  
configuration.  
Setting up advanced initiator CHAP on the storage system  
STEP 1. On your storage system management station, start Navisphere Express on the storage  
STEP 2. In the Navisphere Express navigation pane, under Manage, click iSCSI to open the  
Manage iSCSI screen.  
STEP 3. To set advanced security, click Advanced.  
STEP 4. In the iSCSI Security - Advanced screen, click Initiator CHAP Conguration.  
STEP 5. In the Initiator CHAP Conguration - Advanced screen, click Add.  
The Add Initiator CHAP Credentials - Advanced screen opens.  
STEP 6. In Step 1 on the screen, select the initiator or initiators that will use the new CHAP  
credentials.  
You can allow any initiator to log in with the credentials you specify, (the equivalent of  
basic CHAP), or you can restrict access to a specific initiator. To restrict access, you must  
create a CHAP user for each server initiator.  
Intel Storage System SSR212PP User Guide  
153  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STEP 7. In Step 2 on the screen, enter a CHAP username. This name must match whatever is  
entered as a username for the server.  
You can manually enter a username, or, if logins are restricted to specific initiators  
(STEP 7), you can choose to use the initiator name (IQN) as the CHAP user.  
STEP 8. In Step 3 on the screen, enter and confirm a CHAP secret.  
You will also enter this secret for the server initiators later.  
You can specify the secret in ASCII or hexadecimal characters. ASCII secrets must consist  
of at least 12 and no more than 16 characters. Hexadecimal secrets must consist of at least  
12 and no more than 16 pairs of data (24 to 32 characters). If you specify the CHAP secret  
using hexadecimal characters, you must select CHAP Secret Specied In Hex.  
STEP 9. In Step 4 on the screen, either click Apply to set the advanced initiator CHAP credentials  
or click Cancel to return to the Initiator CHAP Conguration - Advanced screen.  
STEP 10. Click View all initiator CHAP credentials and confirm that the new CHAP entry exists.  
154  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preparing Virtual Disks to  
Receive Data  
27  
Before a server can send data to a virtual disk,  
Linux must recognize the disk, and you must partition the disk and then create and  
mount a file system on it.  
For Windows servers, the virtual disk must be initialized with a signature and you  
must either create partitions on a basic disk or create volumes on a dynamic disk.  
Preparing Virtual Disks for Linux  
STEP 1. On the server, enter  
powermt display dev=all  
The commands shows the paths to all virtual disks on the storage system that the  
servervirtual machine can access. Note the pseudo name for each set of sd devices listed.  
A pseudo name represent a group of paths to a virtual disk; an sd device represents only  
one path. Specifying the pseudo name provides path load balancing and failover, which  
specifying an sd drive does not. Be sure to use the pseudo name in the following steps to  
partition the virtual disk and create and mount a file system on the virtual disk.  
STEP 2. For each virtual disk:  
a. On the server enter  
fdisk /dev/device_name  
where device_name is the pseudo device name for the virtual disk.  
For example: fdisk /dev/emcpowera  
b. From the main fdisk menu, type n and press ENTER to add a new partition.  
c. Type t and press ENTER to change a partition s system ID.  
d. Type L and press ENTER for a list of hex codes for system IDs.  
Linux is type 83; Linux swap is type 82.  
e. Type p and press ENTER to print the partition table so you can verify that the selections  
look correct.  
STEP 3. Type w and press ENTER to write the table to disk and exit fdisk.  
STEP 4. If you want to display the partition numbers created after Linux recognizes them, view the  
file /proc/partitions.  
STEP 5. Create a file system:  
Intel Storage System SSR212PP User Guide  
155  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
mkfs /dev/device_namepartition_number  
where device_name is the pseudo device name for the virtual disk and partition_number is  
the partition number.  
For example:  
For an ext2 file system type: mkfs /dev/emcpowera1  
For an ext3 file system type: mkfs -j /dev/emcpowera1  
For a reiser file system type: mkreiserfs -h r5 /dev/emcpowera1  
STEP 6. When prompted to confirm the construction of a new file system, enter Y and press ENTER.  
STEP 7. Create a mount directory for the file system:  
mkdir / mount_point  
For example:  
mkdir /mnt/emcpowera  
where /mnt/emcpowera is the complete path for the new file system.  
STEP 8. Mount the file system. For a non-network file system:  
mount -t le_system_type/device_partition_name mount_point  
For example:  
mount -t ext2 /dev/emcpowera1 /mnt/emcpowera  
or  
mount -t ext3 /dev/emcpowera1 /mnt/emcpowera  
These commands mount the partition /dev/emcpowera1 onto the mount point  
/mnt/emcpowera as the file system type specified. If you prefer, you can mount the file  
system automatically at boot time by adding this information to the /etc/fstab file. The  
following is an example of an /etc/fstab file entry for a PowerPath device:  
/dev/emcpowera1 /mnt/emcpowera1 ext2 default 0 0  
STEP 9. Save the server s PowerPath configuration:  
powermt save  
This command creates the powermt.ctm configuration file.  
156  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preparing Virtual Disks for Windows  
Microsoft iSCSI Software Initiator does not support dynamic disks.  
STEP 1. Log in to the Windows server as administrator or as a member of an Administrators group.  
STEP 2. On the desktop, right-click My Computer and click Manage.  
STEP 3. In the tree under Storage, click Disk Management.  
STEP 4. If the Write Signature and Upgrade Disk Wizard opens, write a signature to each disk and  
upgrade it to a dynamic disk, if desired:  
a. In the wizard, click Next.  
b. In the Select Disks to Write Signature screen, select all the disks and click Next.  
c. In the Select Disks to Upgrade screen, make sure only the disks that you want to be  
dynamic are selected, and then click Next and Finish.  
The status of a virtual disk goes from unknown to basic or dynamic depending on  
whether you chose to upgrade the disk.  
STEP 5. If the Write Signature and Upgrade Wizard does not open, rescan for the virtual disks,  
write a signature to each disk and upgrade it to a dynamic disk, if desired:  
a. In the Computer Management tree under Storage, right-click Disk Management and  
click Rescan Disks.  
The virtual disks should appear as unknown disks in the Disk Management window. If  
they do not appear, restart Windows, and when Windows is running, rewrite the digital  
signature as described in the previous step.  
b. Right-click any unknown disk in the Disk Management window, and click Write  
Signature.  
c. In the Write Signature Wizard screen, select all the disks and click OK.  
The status of any unknown disks becomes basic.  
d. If you want to upgrade a basic disk to a dynamic disk, right-click the disk, click  
Upgrade to Dynamic Disk, select the disk you want to upgrade, and click OK.  
The status of any basic disks you selected to upgrade becomes dynamic.  
STEP 6. To create Windows partitions on a basic disk for a Windows server  
a. In the Disk Management screen, right-click the free space area of the basic disk that  
you want to partition, and click Create Partition.  
b. In the Create Partition Wizard, click Next and follow the instructions that appear on  
the screen to select a primary or extended partition, specify the partition size, and  
assign a drive letter or path for the partition.  
c. In the Format Partition screen, select Quick Format, and follow the instructions that  
appear.  
Intel Storage System SSR212PP User Guide  
157  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
d. If you want a logical drive on an extended partition, create it:  
i. Right-click the free space area of the extended partition, and click Create Logical  
Drive.  
ii. In the Create Logical Drive Wizard, click Next and click Logical Drive.  
iii. Follow the instructions that appear on the screen to specify the partition size and  
assign a drive letter or path for the partition.  
iv. In the Format Partition screen, select Quick Format, and follow the instructions  
that appear.  
STEP 7. To create volumes on dynamic disks for a Windows server:  
The Navisphere Server Utility cannot assign a drive letter to a snapshot of a  
dynamic disk.  
a. In the Disk Management screen, right-click the free space area for the dynamic disk  
on which you want to create volumes and click Create Volume.  
b. In the Create Volume Wizard, click Next and follow the instructions that appear on the  
screen to specify the volume type, select disks, and assign a drive letter or path for the  
volume.  
c. In the Format Partition screen, select Quick Format, and follow the instructions that  
appear.  
STEP 8. Save the server s PowerPath configuration:  
powermt save  
This command creates the powermt.custom configuration file.  
158  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Verifying the Failover  
28  
Conguration  
Before you store data on virtual disks, use the procedure in this section to verify that:  
The server can send data to and receive data from the storage system.  
You can download an I/O simulator (Iometer) for writing data to the storage system  
from the following website: http://www/iometer.org/.  
PowerPath shows the paths from the server to the virtual disk that you expect for your  
configuration.  
Verifying the Failover Conguration for a Windows 2003  
Server Host  
STEP 1. If you connected a new server to an existing storage system, stop all applications  
accessing the storage system and disable user logins to the server.  
STEP 2. Start PowerPath for iSCSI:  
i. Select Start Settings Control Panel.  
ii. On the Control Panel, do one of the following:  
¥SelectAdministrative Tools Computer Management, or  
¥Click theMy Computer icon on your Desktop and select Manage from the menu.  
The PowerPath iSCSI application resides under the Storage component of the  
Computer Management utility.  
STEP 3. On the Computer Management panel, select PowerPath iSCSI.  
STEP 4. In the left pane, expand Disks.  
STEP 5. Click on each virtual disk to display a list of :paths to the disk, and verify that all paths are  
listed. (Missing or failed paths do not, appear in the list of paths.)  
If a path is missing, refer to the "Troubleshoot" section on the SSR212PP support  
website or the SSR212PP2f-Series Documentation CD.  
STEP 6. Start writing data to a virtual disk.  
STEP 7. For each NIC or iSCSI HBA connected to the storage system:  
a. Disconnect the cable from one NIC or iSCSI HBA connected to the storage system.  
Intel Storage System SSR212PP User Guide  
159  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
b. Scan for hardware changes:  
i. On the desktop, right-click My Computer and click Manage.  
ii. In the tree under System Tools, click Device Manager.  
iii. Click Disk Drives and Scan for hardware changes.  
c. Verify that at least one path is missing to the disk to which you are writing data:  
i. Under PowerPath iSCSI (under Computer Management), expand Disks.  
ii. Click the disk to which you are writing data and verify the its path list has at least  
one path missing.  
d. Reconnect the cable that you disconnected from theNIC or iSCSI HBA.  
e. Scan again for hardware changes:  
i. On the desktop, right-click My Computer and click Manage.  
ii. In the tree under System Tools, click Device Manager.  
iii. Click Disk Drives and then Scan for hardware changes.  
f. Verify the paths to the disk to which you are writing data:  
i. Under PowerPath iSCSI (under Computer Management), expand Disks.  
ii. Click the disk to which you are writing data and verify that its path list has all  
paths listed and that one path is active.  
STEP 8. Restart any applications that you stopped and re-enable any user logins to the server that  
you disabled.  
160  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Verifying the Failover Conguration for a Windows Server  
STEP 1. If you connected a new server to an existing storage system, stop all applications  
accessing the storage system and disable user logins to the server.  
STEP 2. Launch PowerPath Administrator by double-clicking the PowerPath Monitor on the  
Windows task bar.  
STEP 3. On the left pane (summary pane), click EMC PowerPathAdministrator.  
STEP 4. Under the server, right-click Disks.  
The right (details) pane lists all the virtual disks in each storage system connected to the  
server. Storage ID identifies each storage system. For each disk, the Path Status and the  
Path Metric columns give the status of the paths to the disk. When all n paths to a disk are  
working, the Path Status for the disk is optimal and the Path Metric for the disk is n/n,  
indicating that n of n paths are working. If only m paths are working, the path metric is  
m/n.  
STEP 5. Verify that all n paths to the disks in the storage system are working, that is, their status is  
optimal and their path metric is n/n. If not all the paths are working, refer to the  
"Troubleshoot" section on the SSR212PP support website or the SSR212PP-Series  
Documentation CD.  
STEP 6. For each HBA connected to the storage system:  
a. Start writing data to a virtual disk.  
b. Disconnect the cable from oneHBA connected to the storage system.  
c. After several seconds, look at the Details pane and verify that one or more of the disks  
in the storage system have red slashes through them, their status is degraded, and their  
path metric is m/n, where n is the number of paths to the disk and m is the number of  
working paths, which is less than n. For example, if the server has 4 paths to a disk in  
the storage system and 1 path fails when you disconnect the cable, then n=4 and m=3,  
so the path metric is 3/4.  
d. Reconnect the cable that you disconnected from the HBA.  
e. Right-click the PowerPath Monitor icon on the task bar, and select All Tasks and  
Restore All Devices.  
f. After several seconds, look at the details pane and verify that none of the disks in the  
storage system have red slashes through them, their status is optimal, and their path  
metric is n/n.  
STEP 7. Restart any applications that you stopped and re-enable any user logins to the server that  
you disabled.  
Intel Storage System SSR212PP User Guide  
161  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Verifying the Failover Conguration for a Linux Server  
STEP 1. If you connected a new server to an existing storage system, stop all applications  
accessing the storage system and disable user logins to the server.  
STEP 2. For each HBA connected to the storage system:  
a. View the virtual disks available to the server:  
powermt display dev=all  
b. Choose one available virtual disk to receive data (I/O) for the test.  
c. View the paths to the chosen virtual disk:  
powermt display dev= x every=2  
where x is a pseudo device that represents the chosen virtual disk.  
d. Start sending data to a virtual disk by writing data to it.  
e. Identify the HBA sending data to the virtual disk by viewing the output of the  
powermt display dev=x every=2 command, and disconnect the cable to that HBA.  
f. View the output of the powermt display dev=x every=2 command, and verify that:  
The state of the uncabled paths becomes "dead."  
Data continues to be sent on the remaining path(s) to the virtual disk , indicating  
that the failover path was successful and that PowerPath is working properly.  
g. Reconnect the cable that you disconnected from the HBA.  
h. If you caused any virtual disks to fail over, restore the disks to their original SP:  
powermt restore  
STEP 3. Restart any applications that you stopped and re-enable any user logins to the server that  
you disabled.  
162  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Running Navisphere  
Express  
29  
STEP 1. Open an Internet browser on the management host.  
STEP 2. Enter the IP address of an SP in the storage system. This address is the one you assigned  
when you initialized the storage system.  
If Navisphere Express does not open, make sure that the storage system is  
not rebooting. The SP Boot/Fault light on the back of each SP should be off.  
If the storage system is not rebooting and Navisphere Express still does not  
open, go to the "Troubleshoot" section on the SSR212PP support website or  
the SSR212PP-Series Documentation CD.  
STEP 3. Log in to Navisphere Express by entering the username and password that you specified  
when you initialized the storage system.  
To view Navisphere Express in Brazilian Portuguese, English, French,  
German, Italian, Korean, Japanese, Latin American Spanish, or simplified  
Chinese, follow the instructions in Adding a Navisphere Language Pack.  
You can create this document on the SSR212PP2f website by selecting  
Upgrade and then Add Navisphere Language Pack as the upgrade type. Once  
you install a language pack, Navisphere Express automatically opens in that  
language.  
Intel Storage System SSR212PP User Guide  
163  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
164  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Running the Navisphere  
Server Utility  
30  
This procedure provides server-specific instructions for running the Navisphere Server  
Utility on Linux, Netware, and Windows servers.  
On Linux  
STEP 1. On the server, run the utility by entering /opt/Navisphere/bin/naviserverutilcli  
STEP 2. In the Server Utility, enter 1 to select Update Server Information. The utility automatically  
scans for connected SSR212PP-Series storage systems, and displays a list of the ones it  
finds.  
STEP 3. In the Server Utility, enter u to register the server with each storage system the utility  
found.  
The utility sends the server s name and IP address to each storage system. Once the server  
has storage on the storage system, the utility also sends the Linux server device name and  
volume or file system information for each virtual disk in the storage system that the  
server sees.  
STEP 4. Enter c (cancel) to stop the utility.  
On a Windows Server  
You need to run the Server Utility only if you disabled the Registration Service during the  
installation of the utility (it is enabled by default).  
STEP 1. Run the Navisphere Server Utility by clicking  
Start Programs EMC Navisphere Navisphere Server Utility.  
STEP 2. Select your language, if prompted for it.  
STEP 3. In the Navisphere Server Utility dialog box, select Register this server to all connected  
storage systems.  
The utility automatically scans for all connected SSR212PP-Series storage systems and  
lists them under Connected Storage Systems. Locate the WWN of the HBA you just  
installed. The HBA should appear once for every SP port it is connected to.  
Intel Storage System SSR212PP User Guide  
165  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
If the utility is already running, it does not automatically perform a scan, and you  
must click Rescan.  
STEP 4. Click Next to register the server with the storage system.  
To each storage system, the utility sends the server s name and IP address. Once the server  
has storage on the storage system, the utility also sends the device name and volume or  
file system information for each virtual disk in the storage system that the server sees.  
STEP 5. Click Finish to exit the utility.  
166  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Applying iSCSI Data Port  
Addresses to the SP  
Assembly  
31  
Perform the following procedure after replacing an iSCSI storage processor assembly.  
Replacing a Fibre Channel assembly does not require these steps.  
STEP 1. Start Navisphere Express on a management server. See Procedure 29, "Running  
STEP 2. Select Services from the System options, and then Reboot.  
STEP 3. Select Reboot both SPs.  
The storage system takes several minutes to reboot. You can monitor the LEDs on  
the back of the system, or simply wait until the system allows you to restart  
Navisphere Express from the System Reboot page.  
STEP 4. Repeat Steps 1—3.  
STEP 5. Restart Navisphere Express (STEP 1).  
STEP 6. Select iSCSI from the Manage options, then click Apply.  
STEP 7. From the Manage iSCSI page, select Test.  
Intel Storage System SSR212PP User Guide  
167  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
168  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Restoring a Storage  
Processor Boot Image  
32  
This procedure explains how to restore a storage processor s boot image (SP boot image).  
When a storage processor (SP) does not start properly and its fault light blinks four times a  
second, the cause may be that the SP s boot image has been damaged and is unusable. If  
so, a qualified service provider will guide you through the process that this procedure  
describes.  
CAUTION  
Before restoring the boot image, try to correct a startup problem by turning  
power to the storage system off, and then on again.  
Do not attempt the restoration procedure without the assistance of your  
authorized service provider.  
Terminology  
Boot partition A reserved space on one disk, mirrored on another disk, that holds the  
storage processor (SP) operating system. Each SP loads its operating  
system from one of its boot partitions when powered up or reset.  
Image repository  
A reserved space that holds images you can use to restore an SP s boot  
image.  
Primary boot disk  
The lower numbered disk in the mirrored boot pair for an SP. For SPA, it  
is disk 0; for SP B, disk 1.  
SP boot light The amber status lamp visible from the back of an SP. The speed at which  
it blinks indicates the SP startup operation, as follows:  
Blink Behavior  
Meaning  
Every 4 seconds  
Every second  
The SP is running powerup diagnostics.  
The SP is running software diagnostics.  
Four times a second The SP is booting (starting up).  
Off The SP is running normally.  
If the status lamp is on and not blinking then the storage system may have  
a voltage fault or SP fault.  
Intel Storage System SSR212PP User Guide  
169  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Secondary boot disk  
The higher numbered disk in the mirrored boot pair for an SP. For SPA, it  
is disk 2; for SP B, disk 3.  
Utility partition A reserved space on the first four drives of a storage system that holds  
recovery software.  
TABLE 3.  
Locations of Boot and Utility Partitions and Image Repository  
Disks  
0
1
2
3
SP A primary boot  
partition  
SP B primary boot  
partition  
SP A primary boot  
partition  
SP B primary boot  
partition  
SP A primary utility  
partition  
SP A secondary utility  
partition  
SP B primary utility  
partition  
SP B secondary utility  
partition  
Image Repository  
Image Repository  
Image Repository  
Restoring an SP Boot Image  
This procedure describes recovering the SP boot image for a storage processor in an  
SSR212PP-Series storage system.  
Follow this procedure if an SP hangs during startup and cannot boot. An SP indicates that  
it is trying to boot by flashing the amber light on its back panel four times a second. If it  
cannot boot, it continues flashing the light four times each second or remains steadily on.  
Normally, you can recover an SP s boot image using the steps in this section. But if no  
valid SP boot image exists on your storage system, you need to use FTP to load one. See  
STEP 1. Your storage system shipped with a null modem serial cable (service cable) that is unused  
except for service. In some cases, an extra RJ45—DB9 adapter was shipped with the  
service cable.  
If your service cable has a DB9 connector on one end and an RJ45 connector at the other,  
skip this step and continue with STEP 2.  
If your service serial cable has DB9—DB9 connectors, you also need the RJ45—DB9  
adapter cable supplied with your system; connect the serial cable and adapter together.  
The null modem cable and SPS sense cable look similar but are not  
interchangeable. If your system shipment included two RJ45—DB9 adapters, either  
works.  
STEP 2. Connect the service serial cable between a server or laptop s COM 1 or COM 2 port and  
service port of the SP that does not boot.  
Figure 62 shows a cable connection between a COM port and SP A.  
170  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
UPS (SP A only)  
+ -  
Service  
LAN  
COM 1 or COM 2  
EMC3345  
FIGURE 62. Connecting a Server or Laptop COM Port to an SP Service Port  
STEP 3. Start a HyperTerminal session.  
A HyperTerminal session lets you communicate with a device in this case an SP  
connected over a COM port to a Windows server or laptop station.  
If you do not have a Windows station available, you can use terminal emulator  
software for Linux systems. The remainder of this guide describes the steps you  
would encounter using HyperTerminal on a Windows server or laptop; the  
procedure for other systems is similar.  
a. To start a HyperTerminal session, follow this path:  
Start Programs Accessories Communications Hyperterminal  
b. When the software asks for a name, create a meaningful name (for example,  
SSR212PP2f), and then click OK. The software displays a Connect to screen.  
c. In the Connect using box, select COM1 or COM2 from the pull-down list. The  
software displays a settings screen.  
d. Select the following settings:  
Bits per second: 9600  
Data bits: 8  
Parity: None  
Stop bits: 1  
Flow Control: None  
e. Click OK. The HyperTerminal session is now running, as you can see from the timer  
displayed at the lower left of the screen. You use this session to communicate with the  
SP.  
STEP 4. Reset the problem SP, and watch for the alphabetic powerup test display in the  
HyperTerminal window.  
Intel Storage System SSR212PP User Guide  
171  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
The easiest way to reset the SP is to unplug and then plug in the line cord to the SP s  
power supply (Figure 63).  
Retention  
Bail  
EMC3265  
FIGURE 63. Removal of an SP Power Cord from an SSR212PP-Series Power  
Supply  
The SP begins its boot sequence and runs diagnostic tests.  
STEP 5. When the alphabetical test starts, press the Esc key anytime during the sequence shown  
below.  
172  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
FIGURE 64. Screen Shot: Interrupting the Alphabetic Test  
The screen displays the following message: Contact your Service Representative...  
STEP 6. Type recover (case sensitive) and press Enter. The storage processor boots from its utility  
partition and displays messages and a status summary as shown in Figure 65. This  
normally takes 2—4 minutes, but can take longer.  
Intel Storage System SSR212PP User Guide  
173  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
FIGURE 65. Screen Shot: Booting from the Utilities Partition  
STEP 7. Press Enter to continue to the Main Menu (Figure 66).  
174  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
FIGURE 66. Screen Shot:Toolkit Main Menu  
STEP 8. Select Install Images from the menu. The software displays a Select Images to Install  
screen (Figure 67).  
Intel Storage System SSR212PP User Guide  
175  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
FIGURE 67. Screen Shot: Select Images to Install  
STEP 9. Select the recovery image to install. The correct filename has the form  
FLARE-aa.bb.ccc.d.eee.mif.  
CAUTION  
If there is no filename with the form FLARE-aa.bb.ccc.d.eee.mif, then no  
recovery image exists. You cannot continue with this procedure until you have  
After you have specified an image, the software displays the Conrm Image Installation  
screen.  
STEP 10. Enter y if the image selection is correct. The software then displays the Select Storage  
Processors to Install screen.  
STEP 11. Select This SP as the SP you want to recover because it is the SP you physically connected  
with the serial cable.  
For example, if you are restoring the image to SP B, select SP B only. Do not try to restore  
images to both SPs in one procedure.  
After you have selected an SP, the software copies the image to the boot drives of that SP.  
It displays a screen that shows the percentage copied, similar to the one shown in  
Figure 68. The copy may take up to 10 minutes.  
176  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
FIGURE 68. Screen Shot: Copying the Boot Image  
For SSR212PP2f or SSR212PPf (Fibre Channel) systems, skip Steps 12—15  
and continue with STEP 19.  
STEP 12. Verify that the operation completed successfully. You will see Successas shown in  
STEP 13. Press Enter to continue. The software displays the Toolkit Main Menu.  
STEP 14. Select the Reset Storage Processor option.  
The SP boots using the image you selected. It boots 3 times, and each boot may take up to  
3 minutes. Be patient.  
After the SP reboots, the amber LED on the SP back panel should be off.  
STEP 16. Select iSCSI from the Manage options, then select the port settings for the SP whose  
image you just restored and press the Apply button.  
STEP 17. From the Manage iSCSI page, select Test.  
STEP 18. Enter the IP address of the host NIC/HBA, and Ping the host to verify connectivity.  
Intel Storage System SSR212PP User Guide  
177  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STEP 19. Disconnect the service serial cable and adapter (if present) from the SP and the  
server/laptop and store it in a safe place.  
STEP 20. Close your HyperTerminal session. You have restored an SP boot image.  
178  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Using FTP to Obtain and  
Store an SP Boot Image  
33  
This procedure explains how to load and use an SP boot recovery image using FTP (File  
Transfer Protocol).  
Use this procedure if there is no usable recovery image in the storage system. The  
instructions assume that you have opened a HyperTerminal (or equivalent) session and  
If you stopped the preceding recovery procedure at step 6, the software is displaying the  
Select Images to Install screen without a file of the form FLARE-aa.bb.ccc.d.eee.mif  
(compare Figure 69 to the screen shown in Figure 67 on page -176).  
FIGURE 69. Screen Shot: Select Images to Install  
STEP 1. Obtain a recovery file, or information on how to access a recovery file, from your  
authorized service provider. The recovery filename has the form FLARE-  
aa.bb.ccc.d.eee.mif.  
STEP 2. On the Select Images to Install screen, press the Enter key without specifying a number.  
The software displays the Conrm Image Installation screen.  
Intel Storage System SSR212PP User Guide  
179  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
STEP 3. Enter n. The software displays the Toolkit Screen Main Menu.  
STEP 4. Select Enable LAN Service Port. The software displays the Enable LAN Service Port  
screen and prompts for network information.  
STEP 5. As prompted, enter the IP address, subnet mask, and default gateway of the SP you  
connected to the serial port.  
You recorded these parameters on your Administration Worksheet when you  
initially installed your SSR212PP-Series storage system.  
The software confirms the settings you entered and asks if you want to proceed. The entire  
screen, with the information you entered, appears similar to the screen shown in  
FIGURE 70. Screen Shot: Conrm LAN Service Port Conguration  
STEP 6. If the settings are correct, enter y. The software displays the following option:  
Automatically enable the LAN Port with these settings in the future?  
STEP 7. Enter y to continue.  
STEP 8. Open a browser or an FTP client software package using the form ftp://ipAddress, where  
ipAddress is the SP s IP address (for example, ftp://10.14.17.128). When the software  
makes the connection, a login window appears.  
180  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
STEP 9. At the login prompt, enter the username clariion (if not already present) and the password  
clariion!  
STEP 10. Use your browser to select the recovery file obtained from your service provider, and drag  
and drop it into the FTP window.  
STEP 11. Install the SP image in the image repository.  
By putting the image in the repository, you can restore it without using FTP in the  
unlikely event the SP image becomes unusable again.  
a. Select Image Repository Sub-Menu.  
b. Select the option Copy les from RAM disk to Image Repository.  
c. Select the file you just copied using FTP.  
d. Press Enter to continue. The software copies the image to the repository.  
e. Enter 1 to return to the Toolkit Main Menu.  
STEP 12. In the Utility Toolkit window, select Install images.  
STEP 13. Continue the boot image recovery with STEP 6 in Procedure 32, "Restoring a Storage  
Intel Storage System SSR212PP User Guide  
181  
Download from Www.Somanuals.com. All Manuals Search And Download.  
182  
Intel Storage System SSR212PP User Guide  
Revision 1.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Ingersoll Rand Heat Pump WLM2203A X1 User Manual
Ingersoll Rand Marine Sanitation System 650891 X User Manual
Invacare Car Seat Adjustable ASBA Seat User Manual
Jabra Headphones GN9120 DUO User Manual
Jonsered Automobile Parts LT2213 User Manual
Kambrook Computer Drive KEB413 User Manual
Kambrook Microwave Oven KOT700 User Manual
Kawasaki Motorcycle FR600V User Manual
Kenmore Clothes Dryer 110C8508 User Manual
KitchenAid Microwave Oven KBHS109S User Manual