OPENING THE LITE_____________________________________________________________
IKELITE RCD LIGHTS
RCD H, RCD HRechargeable
RCD Super-8, RCD Super-8Rechargeable
R
C
D
R
C
D
I
N
D
P
L
S
I
N
U
.
S
.
A
.
I
N
D
P
L
S
I
N
U
.
S
.
A
.
U
N
L
O
C
K
U
N
L
O
C
K
Pull Out
Rotate
C
D
Flip Up
O
P
E
N
ON/OFF SWITCH FOR RCD H AND HR____________________________________________
R
C
D
Push to
LOCK
I
N
D
P
L
S
I
N
U
.
S
.
A
.
RCD H
– Intense 7.5w medium spot beam powered by 4 D-cell alkaline batteries.
U
N
RCD HR –Ultra-intense rechargeable. Penetrating 19w wide beam with blinding center spot.
L
O
C
K
R
C
D
RCD Super-8
– Super intense 15w light powered by 8 alkaline D-cells. Interchangeable pistol
Switch
UnLocked
and lantern grip handles provided.
I
N
D
P
L
S
I
N
U
.
S
.
A
.
RCD Super-8R – Blinding 25W intensity powered by industrial grade ni-cad module.
Interchangeable pistol and lantern grip handles provided.
RCD – Revolutionary Clamp Design assures easy opening and dependable resealing.
Comfortable hand grip for exploration night or day. Quartz halogen lamp and UV-coated
patterned reflector create a magnificient beam with good peripheral coverage. Virtually
indestructible casing.
U
N
L
O
C
K
Switch
Locked
Rubber shroud protects the front lens while blocking side reflections. Large rotating
switch and sliding lock afford easy operation even when wearing a bulky glove. Nickel
plated brass contacts boost the electrical efficiency and corrosion resistance. Waterproof
to 90m (300 feet).
Legendary Flip-Lock Design –You will never find the RCD stuck shut. Unique flip-lock lever
makes opening and closing incredibly easy and dependable. Simply flip the locking lever up,
rotate, and the internal spring automatically pushes open the light for easy bulb or battery
replacement. Flip the locking lever down and the RCD seals with ease and confidence.
On/Off Switch
Push to
UNLOCK
SWITCH FOR RCD Super-8 MODEL NOT SHOWN__________________________________
NOTE: Ikelite's black vinyl lanyard is NOT recommended for use with RCD Super-8/8R. The
vinyl lanyard is designed to be broken in an emergency and the weight of the Super-8/8R
may cause the lanyard to break during normal use.
Note:
Please read all instructions before using this product.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
RCD Super-8 (Alkaline 8-cell)
RCD HR and SUPER-8R (Rechargeable)
Accepts eight D-cell batteries,
alkaline or ni-cad.
The RCD Super-8 features the super intense 10V halogen
lamp producing an incredibly bright penetrating medium
spot beam intended primarily for underwater use. Alkaline
batteries provide 15W initial intensity and 6 hours of high
intensity light. Consumer ni-cads reduce the intensity and
burn time.
Ultra-intense rechargeables. The RCD HR features a penetrating 19W beam while the
Super-8R provides 25W intensity. Both run for 1.25 hours per charge. Industrial grade 5Ah ni-cad
module produces considerably more power than consumer ni-cads. Not intended for extended
use above water.
+
+
R
E
Z
I
-
R
G
RCD HR
Charger 110/220V USA plug................ Recharge time: 6 hours
Charger 220V European plug............. Recharge time: 6 hours
Smart Charger variable 100-240V, choice of
USA, Euro, Australian plug................. Recharge time: 4 hours
Super8R
14 hours
14 hours
E
E
-
R
E
Z
I
E
G
#0083.9
#0083.91
#4063-series
N
E
R
R
E
N
E
Z
5 hours
BATTERY INSTALLATION_________________________
R
When using charger #0083.9, place 110/220V selector in appropriate position.
E
E
Z
I
•
•
Note the polarity markings on the front head assembly.
G
R
E
The four batteries closest to the handle must be inserted
positive end DOWN; the back four
batteries must be inserted positive end UP.
For best performance, we recommend Energizer®
alkaline batteries.
RECHARGING THE NI-CADS_____________________________________________________
N
E
•
Note the recharge time referenced above. When using the
110/220V charger #0083.9, place the charger's voltage selector
switch in the proper position.
Recharge the ni-cad module in or out of the light. Indicator
light on the module shows that a charge is being accepted;
it does not go out once fully charged. DO NOT continuously
charge the ni-cads longer than 24 hours unless using
Smart Charger.
Charger Socket
Indicator Light
•
+
Spare Bulb
Holder
•
R
E
Z
I
R
E
G
R
E
Z
I
G
N
Nicad Module
R
E
E
N
E
•
•
Recharge the ni-cad module after each use; DO NOT fully
discharge. Definitely recharge the ni-cads if the light intensity
dims; the batteries are nearly depleted. Fully discharging
the ni-cads will shorten the battery life.
Spare Bulb
Holder
H
A
N
D
L
Bulb Holder
Store the ni-cad module fully charged and
Bulb
recharge for a few hours each month.
In our application, the ni-cads should
H
E
O'ring
A
N
D
L
+
+
NOT develop a memory. Fully discharging
ni-cads or allowing
H
A
N
D
L
E
Bulb
O'ring
E
O'ring
them to completely lose a charge does far
more damage than any risk of ni-cad memory.
Rubber
Shroud
+
+
Bulb Holder
O'ring
H
A
N
D
L
E
NI-CAD MODULE INSTALLATION________________________________________________
Rubber
Shroud
•
Note the handle references on the front head assembly and ni-cad module.
•
Ni-cad module MUST be positioned properly on the front.
Otherwise, you will damage the ni-cad module when the body is secured.
BULB #0042.58 REPLACEMENT _________________________________________________
Make sure the bulb is cool. Remove the batteries to access the bulb holder. Squeeze the ends
of bulb holder and remove. Tip the front up and drop the bulb into your hand. Place the new bulb
IKE8 #0042.58 in the front and replace the bulb holder (orient it either way).
BULB REPLACEMENT___________________________________________________________
Use 4.7V bulb #0040.18 for the RCD HR and 6V bulb #0040.20 for the Super-8R. Make sure the
old bulb is cool. Remove ni-cad module to access the bulb holder. Squeeze the ends of bulb holder
and remove. Insert new bulb in the holder. DO NOT touch the bulb because of the oils on your
fingers; use a soft cloth or tissue when replacing. Light intended primarily for undewater use.
In an emergency, use a common PR-size bulb approximating 10V.
5
6
Download from Www.Somanuals.com. All Manuals Search And Download.
INTERCHANGING MODELS
INTERCHANGEABLE HANDLES
RCD H and HR
Only the Super-8 and 8R feature interchangeable handles and both the lantern grip and pistol
grip handles are supplied. To change the handle, access the screw underneath the locking lever by
first sliding the locking lever out and then flip the lever up.
The HR front head assembly is modified for the rechargeable light which means it is NOT
interchangeable with the 4-cell alkaline version RCD. Only the body assembly is interchangeable
between the H and HR models.
Remove the screw and washer and then slide the handle out of the body. Slide the other handle
into the groove and secure with the screw and washer.
SUPER-8 and 8R
NOTE:
Ikelite's black vinyl lanyard is NOT recommended for use with RCD Super-8/8R. The vinyl
The Super-8R front head assembly is modified for the rechargeable light which means it is NOT
interchangeable with the 8-cell alkaline version Super-8. Only the body assembly is interchangeable
between the Super-8 and 8R models.
lanyard is designed to be broken in an emergency and the weight of the Super-8/8R may cause the
lanyard to break during normal use.
REPLACEMENT PARTS
MAINTENANCE_________________________________________________________________
1. We suggest storage of your lite with the locking lever OPEN to allow any potential hydrogen/air
A-E
A-E
A-E
A-E
A
9012.2
mixture to escape.
Head assembly complete with bulb: H
2. The inner ledges of the lite body and front assembly are the sealing surfaces. DO NOT allow
these surfaces to become damaged.
3. Keep the o-ring and sealing surfaces clean. DO NOT stretch the o-ring when cleaning. It is not
necessary to lubricate the o-ring. Never use spray lubricant because it will cause cracking of
the plastics.
4. Occasionally clean the metal contacts for a better connection.
5. The front head assembly has been factory sealed; DO NOT disassemble.
9012.18 Head assembly complete with bulb: HR
9012.88 Head assembly complete with bulb: Super-8
9012.96 Head assembly complete with bulb: Super-8R
0501
9012
Rubber shroud: all models
Head with hydrogen absorber: H
B
B
B
B
C
C
C
C
D
9012.17 Head with hydrogen absorber: HR
9012.80
Head with hydrogen absorber: Super-8
9012.95 Head with hydrogen absorber: Super-8R
0042.55
CAUTION______________________________________________________________________
H BULB, IKE4 5.0V halogen, standard higher intensity
0040.18 HR BULB, 4.7V halogen
0042.58
DO NOT use batteries that have been wet; batteries from a flooded lite should be discarded.
Water could create an internal short circuit at some later date causing a potential explosion. The
normal evolution of all batteries is emitting hydrogen gas. This gas must be absorbed or allowed to
escape to prevent ignition of the entrapped hydrogen/air mixture. We suggest storage of your lite
open to allow any hydrogen/air mixture to escape. A hydrogen absorber has been concealed inside
this lite and should NOT be removed. In case the lite floods, install a new hydrogen absorber in the
spare bulb holder and replace the batteries.
Super-8 BULB, IKE8 10.4V halogen
0042.20 Super-8R BULB, 6V halogen
9012.3
9012.38 Bulb holder/contact bar: HR and Super-8R
Bulb holder/contact bar: H and Super-8
D
E
F
F
0123
9013
9013.8
O-ring: all models
Ni-cad battery module: HR
Ni-cad battery module: Super-8R
IKELITE LIMITED WARRANTY____________________________________________________
All Ikelite products are warranted against any manufacturing defects for a period of one year
from the date of purchase. Defective products should be returned prepaid to Ikelite. Ikelite will,
at its discretion, repair or replace such products, and will return to customer prepaid. All other
claims, of any nature, including but not limited to bulb failure are not covered. Except as men-
tioned above, no other warranty expressed or implied, applies to this Ikelite product.
0083.9 Charger, USA 110/220V 6-hour
0083.91
Charger, Euro 220V 6-hour
9012.5x Body assembly with toggle: note color H and HR
G
G
9012.8x
0910
Body assembly with toggle: note color Super-8 and 8R
Hydrogen absorber
IKELITE UNDERWATER SYSTEMS
50 West 33rd Street
PO Box 88100
Indianapolis, IN 46208 USA
317-923-4523
Email [email protected]
1200-06-0707
7