Wiring
RadioRA 2 Interfacing with Honeywell Vista-128BP
Page 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Overview
Programming a RadioRA 2 system to interface with a Honeywell Vista-128BPT security panel is done in four phases:
1.) Install and program the Honeywell Vista-128BPT security system according to Honeywell instructions.
2.) Program the Vista-128BPT to enable the extra settings to allow the integration, not covered in the Honeywell instructions
(see Appendix 2).
3.) Install and program the Lutron RadioRA 2 system using RadioRA 2 programming software version 5.0 or higher.
4.) Program appropriate phantom buttons associated with each security action, as described in the following section.
Programming Phantom Buttons for Security
Actions in the Honeywell Vista-128BPT security panel will send RS-232 commands to the RadioRA 2 system. Each command is
associated with a specific phantom button, and each phantom button may be programmed to deliver a desired scene. When a
command is received from the security system, the corresponding phantom button is automatically “pressed”. For certain
buttons, a Time of Day feature has been pre-programmed so that the most appropriate action takes place.
The RadioRA 2 Main Repeater has 100 phantom buttons available for use with integration. Buttons 76-100 are configured to
receive commands from the Honeywell Vista Turbo system. Table 1 shows how each security action is associated with RadioRA
2 phantom buttons and Table 2 offers a recommended scene for each phantom button. The Time of Day, when various actions
will take place, is also specified. Table 3 provides a timeline illustrating how the RadioRA 2 system will automatically respond to
various security commands throughout the day.
Note: If the Honeywell Vista-128BPT system has no partitions, use phantom buttons associated with partition 1. See Table 2 for
the phantom button to partition mapping.
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems
Page 4
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1: Security Actions and associated Phantom Buttons (Partition 1)
This table illustrates the various possible actions from a security system and the phantom buttons they will activate depending on Time of
Day. The recommended phantom button scene name is also matched to the phantom button number.
Security Action
Arm Away
Time of Day
Phantom Button(s) Activated
Phantom Button Scene Name
Day
Night
Day
95 + 92
95 + 92
Away Scene + Away Timeclock Mode
Away Scene + Away Timeclock Mode
-
-
Arm Stay
Disarm
Night
Day
93
Goodnight
92 turned off
92 turned off; 94
98 + 99
(Away Timeclock turned off)
(Away Timeclock turned off); Welcome
Exterior Flash, Interior Full
Exterior Flash, Interior Full
Emergency, Exterior Flash
Emergency, Exterior Flash
Night
Day
Intrusion
Emergency
Night
Day
98 + 99
100 + 98
100 + 98
Night
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems
Page 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 2: Phantom Buttons and Recommended Programming
This table provides the recommended programming for each phantom button associated with security on the Main Repeater.
Security Button Type
Phantom System
Recommended Programming
Lights
Recommended
Scene
Plug-in
Modules
Button
Partition
Shades
HVAC
Time Clock
Single/Multi-
room scene
Security mode
Security mode
100
99
98
All
All
All
Emergency*
Interior Full
Exterior Flash
Reserved for
future use
Interior lights at 25%
Interior lights at 100%
Exterior lights flash
Open
Open
-
-
-
-
-
-
-
-
-
-
97
96
95
94
93
All
All
1
-
-
-
-
-
-
-
-
-
-
-
-
Reserved for
future use
-
-
-
Single/Multi-
room scene
Single/Multi-
room scene
Single/Multi-
room scene
Lights off (delayed off on exit
pathway)
Entry, foyer, kitchen lights on to
75%
Away Scene
Welcome
Close
Off
-
1
1
Goodnight
Evening light levels
-
Close
Set Back Off
Away Timeclock
92
91
90
89
88
1
1
2
2
2
Timeclock mode Mode
-
Set Back
-
Away Mode
Reserved for
future use
Away Scene
Welcome
-
-
-
-
-
-
-
-
-
-
Single/Multi-
room scene
Single/Multi-
room scene
Single/Multi-
room scene
Lights off (delayed off on exit
pathway)
Entry, foyer, kitchen lights on to
75%
Close
Off
-
Goodnight
Evening light levels
Close
Set Back Off
Away Timeclock
87
86
2
2
Timeclock mode Mode
Reserved for
future use
-
-
-
-
Set Back
-
-
-
Away Mode
-
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems
Page 6
Download from Www.Somanuals.com. All Manuals Search And Download.
Security Button Type
Phantom System
Recommended Programming
Recommended
Scene
Plug-in
Modules
Button
Partition
Lights
Shades
HVAC
Time Clock
Single/Multi-
room scene
Single/Multi-
room scene
Single/Multi-
room scene
Lights off (delayed off on exit
pathway)
Entry, foyer, kitchen lights on to
75%
85
3
3
3
Away Scene
Welcome
Close
-
-
Off
-
-
-
-
84
83
Goodnight
Evening light levels
-
Close
Set Back Off
Away Timeclock
82
81
80
79
78
3
3
4
4
4
Timeclock mode Mode
Reserved for
-
Set Back
-
Away Mode
future use
Away Scene
Welcome
-
-
-
-
-
-
-
-
-
-
Single/Multi-
room scene
Single/Multi-
room scene
Single/Multi-
room scene
Lights off (delayed off on exit
pathway)
Entry, foyer, kitchen lights on to
75%
Close
Off
-
Goodnight
Evening light levels
Close
Set Back Off
Away Timeclock
77
76
4
4
Timeclock mode Mode
Reserved for
future use
-
-
-
-
Set Back
-
-
-
Away Mode
-
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems
Page 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 3: Security Programming Timelines
When configured according to this tech tip, the RadioRA 2 system will automatically respond to commands from the security keypad
as outlined in the tables below.
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems
Page 8
Download from Www.Somanuals.com. All Manuals Search And Download.
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems
Page 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix 1: Programming the Phantom Buttons
Coming soon: for more in-depth programming instructions, a corresponding Security Training Module can be found online
at resi.lutron.com/radiora2 by following the RadioRA 2 Software Online Training Modules link.
1
2
Once the project has been designed in the RadioRA 2 programming software, select the “Program” tab (1) and then find
the Main Repeater using the “Selected Device Location” drop-down menu (2).
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems
Page 10
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Next, select the desired button from the “Phantom Button” drop-down menu (3).
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems
Page 11
Download from Www.Somanuals.com. All Manuals Search And Download.
5
4
Finally, choose the appropriate “Selected Button Type” (4) and program devices and levels (5).
Remember: you must also complete the activation and transfer steps for the programming to take effect
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems
Page 12
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix 2: Serial Programming Options for Automation Applications
The following group of fields must be set to use the serial port for automation applications:
•
•
•
•
•
•
*05 Enter 1 to send System Event Messages via RS232 port
*14 Enter 0 to disable Home/Facility Automation Control Input
1*70 Event Log Types (Enter 1 in each event log type)
1*78 Extended Home Control Events (Enter 1 for extended)
1*79 Home Control Event Types (Enter 1 in each home control event type)
1*80 Enter 1 to improve automation performance by disabling fault/restore messages over the automation port.
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems
Page 13