Honeywell Home Security System VISTA 128BPT User Manual

Interfacing Lutron RadioRA 2® Systems with  
Honeywell Vista-128BPT Security Systems  
revision A  
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems  
Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring  
RadioRA 2 Interfacing with Honeywell Vista-128BP
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming Overview  
Programming a RadioRA 2 system to interface with a Honeywell Vista-128BPT security panel is done in four phases:  
1.) Install and program the Honeywell Vista-128BPT security system according to Honeywell instructions.  
2.) Program the Vista-128BPT to enable the extra settings to allow the integration, not covered in the Honeywell instructions  
(see Appendix 2).  
3.) Install and program the Lutron RadioRA 2 system using RadioRA 2 programming software version 5.0 or higher.  
4.) Program appropriate phantom buttons associated with each security action, as described in the following section.  
Programming Phantom Buttons for Security  
Actions in the Honeywell Vista-128BPT security panel will send RS-232 commands to the RadioRA 2 system. Each command is  
associated with a specific phantom button, and each phantom button may be programmed to deliver a desired scene. When a  
command is received from the security system, the corresponding phantom button is automatically “pressed”. For certain  
buttons, a Time of Day feature has been pre-programmed so that the most appropriate action takes place.  
The RadioRA 2 Main Repeater has 100 phantom buttons available for use with integration. Buttons 76-100 are configured to  
receive commands from the Honeywell Vista Turbo system. Table 1 shows how each security action is associated with RadioRA  
2 phantom buttons and Table 2 offers a recommended scene for each phantom button. The Time of Day, when various actions  
will take place, is also specified. Table 3 provides a timeline illustrating how the RadioRA 2 system will automatically respond to  
various security commands throughout the day.  
Note: If the Honeywell Vista-128BPT system has no partitions, use phantom buttons associated with partition 1. See Table 2 for  
the phantom button to partition mapping.  
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems  
Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 1: Security Actions and associated Phantom Buttons (Partition 1)  
This table illustrates the various possible actions from a security system and the phantom buttons they will activate depending on Time of  
Day. The recommended phantom button scene name is also matched to the phantom button number.  
Security Action  
Arm Away  
Time of Day  
Phantom Button(s) Activated  
Phantom Button Scene Name  
Day  
Night  
Day  
95 + 92  
95 + 92  
Away Scene + Away Timeclock Mode  
Away Scene + Away Timeclock Mode  
-
-
Arm Stay  
Disarm  
Night  
Day  
93  
Goodnight  
92 turned off  
92 turned off; 94  
98 + 99  
(Away Timeclock turned off)  
(Away Timeclock turned off); Welcome  
Exterior Flash, Interior Full  
Exterior Flash, Interior Full  
Emergency, Exterior Flash  
Emergency, Exterior Flash  
Night  
Day  
Intrusion  
Emergency  
Night  
Day  
98 + 99  
100 + 98  
100 + 98  
Night  
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 2: Phantom Buttons and Recommended Programming  
This table provides the recommended programming for each phantom button associated with security on the Main Repeater.  
Security Button Type  
Phantom System  
Recommended Programming  
Lights  
Recommended  
Scene  
Plug-in  
Modules  
Button  
Partition  
Shades  
HVAC  
Time Clock  
Single/Multi-  
room scene  
Security mode  
Security mode  
100  
99  
98  
All  
All  
All  
Emergency*  
Interior Full  
Exterior Flash  
Reserved for  
future use  
Interior lights at 25%  
Interior lights at 100%  
Exterior lights flash  
Open  
Open  
-
-
-
-
-
-
-
-
-
-
97  
96  
95  
94  
93  
All  
All  
1
-
-
-
-
-
-
-
-
-
-
-
-
Reserved for  
future use  
-
-
-
Single/Multi-  
room scene  
Single/Multi-  
room scene  
Single/Multi-  
room scene  
Lights off (delayed off on exit  
pathway)  
Entry, foyer, kitchen lights on to  
75%  
Away Scene  
Welcome  
Close  
Off  
-
1
1
Goodnight  
Evening light levels  
-
Close  
Set Back Off  
Away Timeclock  
92  
91  
90  
89  
88  
1
1
2
2
2
Timeclock mode Mode  
-
Set Back  
-
Away Mode  
Reserved for  
future use  
Away Scene  
Welcome  
-
-
-
-
-
-
-
-
-
-
Single/Multi-  
room scene  
Single/Multi-  
room scene  
Single/Multi-  
room scene  
Lights off (delayed off on exit  
pathway)  
Entry, foyer, kitchen lights on to  
75%  
Close  
Off  
-
Goodnight  
Evening light levels  
Close  
Set Back Off  
Away Timeclock  
87  
86  
2
2
Timeclock mode Mode  
Reserved for  
future use  
-
-
-
-
Set Back  
-
-
-
Away Mode  
-
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems  
Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Security Button Type  
Phantom System  
Recommended Programming  
Recommended  
Scene  
Plug-in  
Modules  
Button  
Partition  
Lights  
Shades  
HVAC  
Time Clock  
Single/Multi-  
room scene  
Single/Multi-  
room scene  
Single/Multi-  
room scene  
Lights off (delayed off on exit  
pathway)  
Entry, foyer, kitchen lights on to  
75%  
85  
3
3
3
Away Scene  
Welcome  
Close  
-
-
Off  
-
-
-
-
84  
83  
Goodnight  
Evening light levels  
-
Close  
Set Back Off  
Away Timeclock  
82  
81  
80  
79  
78  
3
3
4
4
4
Timeclock mode Mode  
Reserved for  
-
Set Back  
-
Away Mode  
future use  
Away Scene  
Welcome  
-
-
-
-
-
-
-
-
-
-
Single/Multi-  
room scene  
Single/Multi-  
room scene  
Single/Multi-  
room scene  
Lights off (delayed off on exit  
pathway)  
Entry, foyer, kitchen lights on to  
75%  
Close  
Off  
-
Goodnight  
Evening light levels  
Close  
Set Back Off  
Away Timeclock  
77  
76  
4
4
Timeclock mode Mode  
Reserved for  
future use  
-
-
-
-
Set Back  
-
-
-
Away Mode  
-
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 3: Security Programming Timelines  
When configured according to this tech tip, the RadioRA 2 system will automatically respond to commands from the security keypad  
as outlined in the tables below.  
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems  
Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix 1: Programming the Phantom Buttons  
Coming soon: for more in-depth programming instructions, a corresponding Security Training Module can be found online  
at resi.lutron.com/radiora2 by following the RadioRA 2 Software Online Training Modules link.  
1
2
Once the project has been designed in the RadioRA 2 programming software, select the “Program” tab (1) and then find  
the Main Repeater using the “Selected Device Location” drop-down menu (2).  
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems  
Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
Next, select the desired button from the “Phantom Button” drop-down menu (3).  
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems  
Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
4
Finally, choose the appropriate “Selected Button Type” (4) and program devices and levels (5).  
Remember: you must also complete the activation and transfer steps for the programming to take effect  
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems  
Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix 2: Serial Programming Options for Automation Applications  
The following group of fields must be set to use the serial port for automation applications:  
*05 Enter 1 to send System Event Messages via RS232 port  
*14 Enter 0 to disable Home/Facility Automation Control Input  
1*70 Event Log Types (Enter 1 in each event log type)  
1*78 Extended Home Control Events (Enter 1 for extended)  
1*79 Home Control Event Types (Enter 1 in each home control event type)  
1*80 Enter 1 to improve automation performance by disabling fault/restore messages over the automation port.  
RadioRA 2 Interfacing with Honeywell Vista-128BPT Security Systems  
Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Guardian Technologies Portable Generator 02010 2 User Manual
Hasbro Baby Toy 62320 User Manual
Honeywell Automobile Parts vc7900 User Manual
Hotpoint Refrigerator RFR51V User Manual
Hotpoint Washer AQ1131 User Manual
HP Hewlett Packard Water Dispenser 5308A User Manual
Huey Chiao Bluetooth Headset HCB19 User Manual
Humminbird Fish Finder Wide 3D Vision User Manual
Hunter Fan Outdoor Ceiling Fan 21583 User Manual
IBM Network Card EM78P259N 260N User Manual