VoyagerTM 1250gAP
Single-Line Laser Scanner
User’s Guide
™
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
i
Download from Www.Somanuals.com. All Manuals Search And Download.
Aux Port Configuration ............................................2-10
RS232 Word Length: Data Bits, Stop Bits,
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
Manual Activation Laser Timeout -
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
To Add a Carriage Return Suffix to
Intercharacter, Interfunction, and
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
v
Download from Www.Somanuals.com. All Manuals Search And Download.
EAN-13 Beginning with 378/379
EAN-13 Beginning with 414/419
EAN-13 Beginning with 434/439
vi
Download from Www.Somanuals.com. All Manuals Search And Download.
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
viii
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Agency Compliance
USA
FCC Part 15 Subpart B Class B
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a
Class B digital device pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses, and can radi-
ate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communica-
tions. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equip-
ment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
•
Consult the dealer or an experienced radio or television technician for
help.
If necessary, the user should consult the dealer or an experienced radio/
television technician for additional suggestions. The user may find the fol-
lowing booklet helpful: “Something About Interference.” This is available at
FCC local regional offices. Honeywell is not responsible for any radio or
television interference caused by unauthorized modifications of this equip-
ment or the substitution or attachment of connecting cables and equipment
other than those specified by Honeywell. The correction is the responsibil-
ity of the user.
Use only shielded data cables with this system. This unit has been tested
with cables less than 3 meters. Cables greater than 3 meters may not meet
class B performance.
Caution: Any changes or modifications made to this equipment not
expressly approved by Honeywell may void the FCC authorization to oper-
ate this equipment.
UL Statement
UL listed: UL60950-1, 2nd Edition.
Download from Www.Somanuals.com. All Manuals Search And Download.
This product is intended to be supplied by a Listed Direct Plug-In Power
unit marked "Class 2" or "LPS" and rated 5 Vdc - 5.2 Vdc, 1A.
Canada
Industry Canada ICES-003
This Class B digital apparatus complies with Canadian ICES-003. Opera-
tion is subject to the following conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
Conformité à la règlementation canadienne
Cet appareil numérique de la Classe A est conforme à la norme NMB-003
du Canada. Son fonctionnement est assujetti aux conditions suivantes :
1. Cet appareil ne doit pas causer de brouillage préjudiciable.
2. Cet appareil doit pouvoir accepter tout brouillage reçu, y compris le
brouillage pouvant causer un fonctionnement indésirable.
C-UL Statement
C-UL listed: CSA C22.2 No.60950-1-07, 2nd Edition.
Europe
The CE marking indicates compliance to 2004/108/EC EMC Directive
with Standards EN55022 CLASS B, EN55024, EN61000-3-2,
EN61000-3-3. In addition, complies to 2006/95/EC Low Voltage Direc-
tive, when shipped with recommended power supply.
For further information please contact:
Hand Held Products Europe BV
Nijverheidsweg 9-13
5627 BT Eindhoven
The Netherlands
Honeywell International Inc. shall not be liable for use of our product with
equipment (i.e., power supplies, personal computers, etc.) that is not CE
marked and does not comply with the Low Voltage Directive.
Honeywell Scanning & Mobility Product
Environmental Information
WEEE information.
Download from Www.Somanuals.com. All Manuals Search And Download.
Australia/NZ
C-Tick Statement
Conforms to AS/NZS 3548
Germany
If your product is marked with the GS symbol, then the product
has been issued a GS certificate showing compliance to EN
60950-1, Second Edition.
This device is not intended for use in direct field of view at visual display
workplaces. To avoid distracting reflections at visual display workplaces,
this device should not be placed in direct field of view.
Mexico
Conforms to NOM-019.
Gost-R certificate
Russia
South Korea
This product meets Korean agency approval.
Tawain
BSMI Standard: CNS13438, CNS 14336
Download from Www.Somanuals.com. All Manuals Search And Download.
International
Laser Safety Statement
LASER LIGHT: DO NOT STARE INTO
BEAM. CLASS 2 LASER PRODUCT.
LASERSTRAHLUNG: NICHT IN DEN
STRAHL BLICKEN. LASER KLASSE 2.
LUMIERE LASER: NE PAS REGARDER
DANS LE FAISCEAU. APPAREIL A LASER.
DE CLASSE 2 630-650nm, 1mW.
This device has been tested in accordance with and complies with
IEC60825-1 ed2.0 and 21 CFR 1040.10 and 1040.11, except for deviations
pursuant to Laser Notice No. 50, dated June 24, 2007.
LASER LIGHT, DO NOT STARE INTO BEAM, CLASS 2 LASER PROD-
UCT, 1 mW MAX OUTPUT: 630-650nM.
Scanner Laser Beam
Wavelength 630 - 650 nm
Divergence < 1.5 mrad. per IEC 60825-1 worst case
Max power output < 1mw
Embedded Laser
Wavelength 630 - 650 nm
Divergence < 1.5 mrad, per IEC 60825-1 worst case
Max power output < 10 mw
Caution: Use of controls or adjustments or performance of
procedures other than those specified herein may
result in hazardous radiation exposure.
CB Scheme
Certified to CB Scheme IEC60950-1, Second Edition.
Solids and Water Protection
The Voyager 1250gAP has a rating of IP42, immunity of foreign particles and
dripping water.
Patents
Download from Www.Somanuals.com. All Manuals Search And Download.
Required Safety Label Locations
Laser Output
Laser Safety
information
Part Number,
Serial Number
Laser Label,
and Revision
Information
location
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
1
Getting Started
About This Manual
This User’s Guide provides installation and programming instructions for the
Voyager 1250gAP single-line laser scanner. Product specifications, dimen-
sions, warranty, and customer support information are also included.
Honeywell bar code scanners are factory programmed for the most common
terminal and communications settings. If you need to change these settings,
programming is accomplished by scanning the bar codes in this guide.
An asterisk (*) next to an option indicates the default setting.
Unpacking Your Device
After you open the shipping carton containing the product, take the following
steps:
•
Check for damage during shipment. Report damage immediately to the
carrier who delivered the carton.
•
•
Make sure the items in the carton match your order.
Save the shipping container for later storage or shipping.
Connecting the Device
Connecting with USB
A scanner can be connected to the USB port of a computer.
1. Connect the appropriate interface cable to the scanner first, then to
the computer.
1 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
2. The scanner beeps.
Symbols in the back of this manual.
terminal settings.
Connecting with Keyboard Wedge
A scanner can be connected between the keyboard and PC as a “keyboard
wedge,” plugged into the serial port, or connected to a portable data termi-
nal in wand emulation or non decoded output mode. The following is an
example of a keyboard wedge connection:
1. Turn off power and disconnect the keyboard cable from the back of the
terminal/computer.
2. Connect the appropriate interface cable to the scanner and to the
terminal/computer.
only if
power
supply is
included
3. Turn the terminal/computer power back on. The scanner beeps.
The unit defaults to an IBM PC AT and compatibles keyboard wedge inter-
face with a USA keyboard. A carriage return (CR) suffix is added to bar
code data.
1 - 2
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting with RS232 Serial Port
1. Turn off power to the terminal/computer.
2. Connect the appropriate interface cable to the scanner.
only if
power
supply is
included
3. Plug the serial connector into the serial port on your computer.
Tighten the two screws to secure the connector to the port.
4. Once the scanner has been fully connected, power up the computer.
This interface programs 9600 baud, 8 data bits, no parity, and 1 stop bit.
1 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting with RS485
A scanner can be connected for an IBM POS terminal interface.
1. Connect the appropriate interface cable to the device, then to the com-
puter.
2. Turn the terminal/computer power back on. The scanner beeps.
1 - 4
Download from Www.Somanuals.com. All Manuals Search And Download.
Reading Techniques
The scanner has a view finder that projects a bright red aiming beam that corre-
sponds to the scanner’s horizontal field of view. The aiming beam should be
centered horizontally over the bar code and must highlight all the vertical bars of
the bar code. It will not read if the aiming beam is in any other direction.
Good Read
Bad Read
The aiming beam is smaller when the scanner is closer to the code and larger
when it is farther from the code. Symbologies with smaller bars or elements (mil
size) should be read closer to the unit. Symbologies with larger bars or ele-
ments (mil size) should be read farther from the unit. To read single or multiple
symbols (on a page or on an object), hold the scanner at an appropriate dis-
tance from the target, pull the trigger, and center the aiming beam on the sym-
bol. If the code being scanned is highly reflective (e.g., laminated), it may be
necessary to tilt the code up 15° to 18° to prevent unwanted reflection.
Menu Bar Code Security Settings
Honeywell scanners are programmed by scanning menu bar codes or by send-
ing serial commands to the scanner. If you want to restrict the ability to scan
menu codes, you can use the Menu Bar Code Security settings. Please contact
further information.
Setting Custom Defaults
You have the ability to create a set of menu commands as your own, custom
defaults. To do so, scan the Set Custom Defaults bar code below before each
menu command or sequence you want saved. If your command requires scan-
sequence will be saved to your custom defaults. Scan the Set Custom
Defaults code again before the next command you want saved to your custom
defaults.
1 - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
When you have entered all the commands you want to save for your custom
defaults, scan the Save Custom Defaults bar code.
Set Custom Defaults
Save Custom Defaults
You may have a series of custom settings and want to correct a single setting.
To do so, just scan the new setting to overwrite the old one. For example, if you
had previously saved the setting for Beeper Volume at Low to your custom
defaults, and decide you want the beeper volume set to High, just scan the Set
Custom Defaults bar code, then scan the Beeper Volume High menu code,
and then Save Custom Defaults. The rest of the custom defaults will remain,
but the beeper volume setting will be updated.
Resetting the Custom Defaults
If you want the custom default settings restored to your scanner, scan the Acti-
vate Custom Defaults bar code below. This resets the scanner to the custom
default settings. If there are no custom defaults, it will reset the scanner to the
factory default settings. Any settings that have not been specified through the
custom defaults will be defaulted to the factory default settings.
Activate Custom Defaults
default settings for each of the commands (indicated by an asterisk (*) on the
programming pages).
1 - 6
Download from Www.Somanuals.com. All Manuals Search And Download.
2
Programming the Interface
Introduction
This chapter describes how to program your system for the desired interface.
Programming the Interface - Plug and Play
Plug and Play bar codes provide instant scanner set up for commonly used
interfaces.
Note: After you scan one of the codes, power cycle the host terminal to have
the interface in effect.
Keyboard Wedge
If you want your system programmed for an IBM PC AT and compatibles
keyboard wedge interface with a USA keyboard, scan the bar code below.
Keyboard wedge is the default interface.
Note: The following bar code also programs a carriage return (CR) suffix.
IBM PC AT and Compatibles with CR Suffix
IBM PS2 Keyboard
The following bar code programs you scanner for an IBM PS2 keyboard
wedge interface with a USA keyboard.
Note: The following bar code also programs a carriage return (CR) suffix.
IBM PS2 with CR Suffix
RS232 Serial Port
The RS232 Interface bar code is used when connecting to the serial port
of a PC or terminal. The following RS232 Interface bar code also pro-
grams a carriage return (CR) and a line feed (LF) suffix, baud rate, and
data format as indicated below.
Option
Setting
Baud Rate
9600 bps
Data Format
8 data bits, no parity bit, 1 stop bit
2 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
RS232 Interface
RS485
Scan one of the following “Plug and Play” codes to program the scanner for
an IBM POS terminal interface.
Note: After scanning one of these codes, you must power cycle the cash
register.
IBM Port 5B Interface
IBM Port 9B
HHBCR-1 Interface
IBM Port 17 Interface
IBM Port 9B
HHBCR-2 Interface
Each bar code above also programs the following suffixes for each symbol-
ogy:
Symbology Suffix
Symbology
Suffix
EAN 8
EAN 13
UPC A
UPC E
0C
16
0D
0A
Code 39
00 0A 0B
00 0D 0B
00 0A 0B
00 18 0B
Interleaved 2 of 5
Code 128 *
Code 128 **
* Suffixes programmed for Code 128 with IBM 4683 Port 5B, IBM 4683 Port 9B
HHBCR-1, and IBM 4683 Port 17 Interfaces
**Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR-2 Interface
2 - 2
Download from Www.Somanuals.com. All Manuals Search And Download.
OPOS Mode
The following bar code configures your scanner for OPOS (OLE for Retail
Point of Sale) by modifying the following OPOS-related settings:
Option
Setting
Interface
RS232
Baud Rate
38400
RS232
Handshaking
Flow Control, No Timeout
XON/XOFF Off
ACK/NAK Off
Data Bits, Stop
Bits, and Parity
Prefix/Suffix
8 Data, 1 Stop, Parity None
Clear All Prefixes and Suffixes
Add Code ID and AIM ID Prefix
Add CR Suffix
Intercharacter
Delay
Off
Symbologies
Enable UPC-A with check digit and number system
Enable UPC-E0 with check digit
Enable EAN/JAN-8 with check digit
Enable EAN/JAN-13 with check digit
Enable Code 128
Enable Code 39
Enable OPOS with automatic disable off
OPOS Mode
2 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
USB IBM SurePos
Scan one of the following “Plug and Play” codes to program the scanner for
an IBM SurePos (USB handheld scanner) or IBM SurePos (USB tabletop
scanner) interface.
Note: After scanning one of these codes, you must power cycle the cash
register.
USB IBM SurePos
(USB Handheld Scanner)
Interface
USB IBM SurePos
(USB Tabletop Scanner)
Interface
Each bar code above also programs the following suffixes for each symbol-
ogy:
Symbology
Suffix
Symbology
Suffix
EAN 8
EAN 13
UPC A
UPC E
0C
16
0D
0A
Code 39
Interleaved 2 of 5
Code 128
00 0A 0B
00 0D 0B
00 18 0B
00 0A 0B
Code 39
IBM Secondary Interface
On some older IBM cash registers, it may be necessary to disable the sec-
ondary or management interface. In particular, it has been found neces-
sary on IBM registers using the 4690 V2R4 operating system. The
following bar codes are used for this purpose. Default = Enable Secondary
Interface.
*Enable Secondary Interface
Disable Secondary Interface
2 - 4
Download from Www.Somanuals.com. All Manuals Search And Download.
USB PC or Macintosh Keyboard
Scan one of the following codes to program the scanner for USB PC Key-
board or USB Macintosh Keyboard. Scanning these codes also adds a CR
and LF.
d (PC)
USB Keyboar
USB Keyboard (Mac)
USB Japanese Keyboard (PC)
USB HID
Scan the following code to program the scanner for USB HID bar code
scanners.
USB HID Bar Code Scanner
HID Fallback Mode
If you attempt to set a USB interface for your scanner, but the setup fails on
the host system, you can program the scanner to fall back to a HID key-
board interface after a set length of time. For example, if the scanner is
configured for Serial Emulation Mode, but the host system does not have
the correct driver, the scanner would fail. If you set the HID Fallback Mode
for a set length of time, for example, 5 minutes, the scanner would change
to a HID keyboard interface after 5 minutes of trying to configure as serial
emulation.
A unique beep sequence indicates that this mode has been entered. While
in HID Fallback Mode, the scanner will not scan normal bar codes and
sounds a unique beep sequence that indicates the scanner is in Fallback
Mode. Menu codes can still be scanned while in HID Fallback Mode, allow-
ing you to change the scanner’s programming.
2 - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Scan the bar code below, then set the length for the HID Fallback (from 0-
HID Fallback Mode
USB Serial Commands
USB Serial Emulation
Scan one of the following codes to program the scanner to emulate a regu-
lar RS232-based COM Port. If you are using a Microsoft® Windows® PC,
you will need to download a driver from the Honeywell website
number. Apple® Macintosh computers recognize the scanner as a USB
CDC class device and automatically uses a class driver.
Scanning either of these codes also adds a CR and LF.
USB Serial Emulation for
Windows XP, Windows Server
2003, and later
USB Serial Emulation for Windows 2000
Note: No extra configuration (e.g., baud rate) is necessary.
CTS/RTS Emulation
CTS/RTS Emulation On
* CTS/RTS Emulation Off
2 - 6
Download from Www.Somanuals.com. All Manuals Search And Download.
ACK/NAK Mode
ACK/NAK Mode On
* ACK/NAK Mode Off
Communication Timeout
This allows you to set the length (in milliseconds) for a timeout for the host
ACK/NAK response. Scan the bar code below, then set the timeout (from
Communication Timeout
Timeout Retries
This setting limits the number of Communication Timeout retries. If the
Timeout Retries is set to 0, the transmission is terminated after the ini-
tial Communication Timeout. Scan the bar code below, then set the
number of retries (from 0-255) by scanning digits from the
ting.) Default = 0.
Timeout Retries
2 - 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Communication Timeout Beeper
This selection programs the scanner to issue an error beep when a
communication timeout has occurred. The error beep sound is pro-
Off
* On
NAK Retries
This selection limits the number of NAK retries that can occur in ACK/NAK
mode. Scan the bar code below, then set the number of retries (from 0-
(5 is the recommended setting.) Default = 0, or disabled.
NAK Retries
Support BEL/CAN in ACK/NAK
This protocol responds to <BEL> and <CAN> commands when in ACK/
NAK mode. The scanner sounds an error tone when a <BEL> command is
sent from the host. <CAN> terminates the transmission. Default = BEL/
CAN Off.
BEL/CAN On
* BEL/CAN Off
2 - 8
Download from Www.Somanuals.com. All Manuals Search And Download.
®
Verifone Ruby Terminal Default Settings
Scan the following Plug and Play code to program the scanner for a Verifone
Ruby terminal. This bar code sets the baud rate to 1200 bps and the data for-
mat to 8 data bits, Mark parity, 1 stop bit and RTS/CTS no timeout. It also adds
a line feed (LF) suffix and programs the following prefixes for each symbology:
Symbology
Prefix
UPC-A
UPC-E
EAN-8
EAN-13
A
A
FF
F
Verifone Ruby Settings
Note: If you are having unexpected results with this programming code, scan
programming bar code above.
®
Gilbarco Terminal Default Settings
Scan the following Plug and Play code to program the scanner for a Gilbarco
terminal. This bar code sets the baud rate to 2400 bps and the data format to 7
data bits, even parity, 2 stop bits. It also adds a carriage return (CR) suffix and
programs the following prefixes for each symbology:
Symbology
Prefix
UPC-A
UPC-E
EAN-8
EAN-13
A
E0
FF
F
Gilbarco Settings
Note: If you are having unexpected results with this programming code, scan
programming bar code above.
2 - 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Honeywell Bioptic Aux Port Configuration
Scan the following Plug and Play code to program the scanner for a Honeywell
bioptic scanner auxiliary port configuration. This bar code sets the baud rate to
38400 bps and the data format to 8 data bits, no parity, 1 stop bit. Character
RTS/CTS with timeout and 232 ACK/NAK are also enabled.
Honeywell Bioptic Settings
Note: If you are having unexpected results with this programming code, scan
programming bar code above.
©
Datalogic™ Magellan Bioptic
Aux Port Configuration
Scan the following Plug and Play code to program the scanner for a Datalogic
Magellan bioptic scanner auxiliary port configuration. This bar code sets the
baud rate to 9600 bps and the data format to 8 data bits, no parity, 1 stop bit.
Datalogic Magellan Bioptic Settings
Note: If you are having unexpected results with this programming code, scan
programming bar code above.
NCR Bioptic Aux Port Configuration
Scan the following Plug and Play code to program the scanner for an NCR biop-
tic scanner auxiliary port configuration. This bar code sets the baud rate to
9600 bps and the data format to 7 data bits, Even parity, 1 stop bit and Message
RTS/CTS with timeout. The following prefixes are programmed for each sym-
bology:
Symbology
Prefix
Symbology
Prefix
UPC-A
UPC-E
EAN-8
A
E0
FF
Code 39
B1
B2
B3
Interleaved 2 of 5
All other bar
codes
EAN-13
F
2 - 10
Download from Www.Somanuals.com. All Manuals Search And Download.
NCR Bioptic Settings
Note: If you are having unexpected results with this programming code, scan
programming bar code above.
Wincor Nixdorf Terminal Default Settings
Scan the following Plug and Play code to program the scanner for a Wincor Nix-
dorf terminal. This bar code sets the baud rate to 9600 bps and the data format
to 8 data bits, no parity, 1 stop bit.
Wincor Nixdorf Terminal Settings
Note: If you are having unexpected results with this programming code, scan
programming bar code above.
2 - 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Wincor Nixdorf Beetle™
Terminal Default Settings
Scan the following Plug and Play code to program the scanner for a Wincor Nix-
dorf Beetle terminal. The following prefixes are programmed for each symbol-
ogy:
Symbology
Prefix
Symbology
EAN-13
GS1-128
Interleaved 2 of 5
Plessey
Straight 2 of 5 IATA
All other bar codes
Prefix
Code 128
Code 93
Codabar
UPC-A
UPC-E
EAN-8
K
L
N
A0
C
B
A
P
I
O
H
M
Wincor Nixdorf Beetle Settings
Note: If you are having unexpected results with this programming code, scan
programming bar code above.
2 - 12
Download from Www.Somanuals.com. All Manuals Search And Download.
Wincor Nixdorf RS232 Mode A
Scan the following Plug and Play code to program the scanner for a Wincor Nix-
dorf RS232 Mode A terminal. The following prefixes are programmed for each
symbology:
Symbology
Prefix
Symbology
EAN-13
GS1-128
Interleaved 2 of 5
Plessey
Straight 2 of 5 IATA
GS1 DataBar
Prefix
Code 128
Code 93
Codabar
UPC-A
UPC-E
EAN-8
K
L
N
A0
C
B
A
K
I
O
H
E
All other bar codes
M
Wincor Nixdorf RS232 Mode A
Settings
2 - 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Keyboard Country Layout
Scan the appropriate country code below to program the keyboard layout for
your country or language. As a general rule, the following characters are sup-
ported, but need special care for countries other than the United States:
@ | $ # { } [ ] = / ‘ \ < > ~
* United States
Albania
Arabic
Azeri (Cyrillic)
Azeri (Latin)
Belarus
Belgium
Bosnia
Brazil
Brazil (MS)
Bulgaria (Cyrillic)
Bulgaria (Latin)
2 - 14
Download from Www.Somanuals.com. All Manuals Search And Download.
Keyboard Country (continued)
Turkey F
Turkey Q
Ukrainian
United Kingdom
United Stated (Dvorak right)
United States (Dvorak left)
United States (Dvorak)
Uzbek (Cyrillic)
United States (International)
Vietnam
Keyboard Wedge Modifiers
ALT Mode
If your bar code contains special characters from the extended ASCII chart
Note: Scan the ALT mode bar code after scanning the appropriate
Keyboard Country code.
2 - 20
Download from Www.Somanuals.com. All Manuals Search And Download.
If your keystrokes require using the ALT key and 3 characters, scan the 3
Characters bar code. If your keystrokes require the ALT key and 4 charac-
ters, scan the 4 Characters bar code. The data is then output with the spe-
cial character(s). Default = Off.
* Off
3 Characters
4 Characters
Keyboard Style
This programs keyboard styles, such as Caps Lock and Shift Lock. If you
lowing Keyboard Style settings. Default = Regular.
Regular is used when you normally have the Caps Lock key off.
* Regular
Caps Lock is used when you normally have the Caps Lock key on.
Caps Lock
Shift Lock is used when you normally have the Shift Lock key on (not com-
mon to U.S. keyboards).
Shift Lock
2 - 21
Download from Www.Somanuals.com. All Manuals Search And Download.
Autocaps via NumLock bar code should be scanned in countries (e.g.,
Germany, France) where the Caps Lock key cannot be used to toggle Caps
Lock. The NumLock option works similarly to the regular Autocaps, but
uses the NumLock key to retrieve the current state of the Caps Lock.
Autocaps via NumLock
Emulate External Keyboard should be scanned if you do not have an
external keyboard (IBM AT or equivalent).
Emulate External Keyboard
Note: After scanning the Emulate External Keyboard bar code, you must
power cycle your computer.
Keyboard Conversion
Alphabetic keyboard characters can be forced to be all upper case or all
lowercase. So if you have the following bar code: “abc569GK,” you can
make the output “ABC569GK” by scanning Convert All Characters to
Upper Case, or to “abc569gk” by scanning Convert All Characters to
Default = Keyboard Conversion Off.
* Keyboard Conversion Off
Convert All Characters to Upper
Case
Convert All Characters to Lower
Case
Keyboard Modifiers
This modifies special keyboard features, such as CTRL+ ASCII codes and
Turbo Mode.
2 - 22
Download from Www.Somanuals.com. All Manuals Search And Download.
Control + ASCII Mode On: The scanner sends key combinations for ASCII
control characters for values 00-1F (refer to the ASCII Conversion Chart
board country codes are supported. DOS mode is a legacy mode, and it
does not support all keyboard country codes. New users should use the
Windows mode.
Windows Mode Prefix/Suffix Off: The scanner sends key combinations
for ASCII control characters for values 00-1F (refer to the ASCII Conversion
suffix information.
Default = Control + ASCII Mode Off.
Windows Mode Control + ASCII
Mode On
* Control + ASCII Mode Off
DOS Mode Control + ASCII Mode
On
Windows Mode Prefix/Suffix Off
Numeric Keypad Mode: Sends numeric characters as if entered from a
numeric keypad. Default = Off.
Numeric Keypad Mode On
* Numeric Keypad Mode Off
Inter-Scan Code Delay
When your keyboard detects that any key is being pressed, released, or
held down, the keyboard sends a packet of information known as a “scan
code” to your computer. This selection allows you to adjust the delay
between scan codes. Set the length (in milliseconds) for a delay by scan-
2 - 23
Download from Www.Somanuals.com. All Manuals Search And Download.
ning the bar code below, then setting the delay (from 1-30) by scanning dig-
Inter-Scan Code Delay
<F0> Break Character
When your keyboard detects that any key is being pressed, released, or
held down, the keyboard sends a packet of information known as a “scan
code” to your computer. There are two different types of scan codes:
“make codes” and “break codes.” A make code is sent when a key is
pressed or held down. A break code is sent when a key is released. The
following selections allow you to suppress or transmit the character
sequence of the break code. Default = Transmit.
Suppress
* Transmit
Keyboard Wedge Defaults
If you want the custom keyboard wedge default settings restored to your
scanner, scan the Keyboard Wedge Defaults bar code below. This resets
factory default settings. Any settings that have not been specified through
the custom defaults will be defaulted to the factory default settings.
Keyboard Wedge Defaults
2 - 24
Download from Www.Somanuals.com. All Manuals Search And Download.
RS232 Modifiers
RS232 Baud Rate
Baud Rate sends the data from the scanner to the terminal at the specified
rate. The host terminal must be set for the same baud rate as the scanner.
Default = 9600.
300
600
1200
2400
4800
* 9600
19200
38400
57,600
115,200
2 - 25
Download from Www.Somanuals.com. All Manuals Search And Download.
RS232 Word Length: Data Bits, Stop Bits,
and Parity
Data Bits sets the word length at 7 or 8 bits of data per character. If an
application requires only ASCII Hex characters 0 through 7F decimal (text,
digits, and punctuation), select 7 data bits. For applications that require
use of the full ASCII set, select 8 data bits per character. Default = 8.
Stop Bits sets the stop bits at 1 or 2. Default = 1.
Parity provides a means of checking character bit patterns for validity.
Default = None.
7 Data, 1 Stop, Parity Even
7 Data, 1 Stop, Parity None
7 Data, 1 Stop, Parity Odd
7 Data, 2 Stop, Parity Even
7 Data, 2 Stop Parity None
7 Data, 2 Stop, Parity Odd
8 Data, 1 Stop, Parity Even
* 8 Data, 1 Stop, Parity None
8 Data, 1 Stop, Parity Odd
7 Data, 1 Stop, Parity Space
2 - 26
Download from Www.Somanuals.com. All Manuals Search And Download.
7 Data, 2 Stop, Parity Space
7 Data, 1 Stop, Parity Mark
8 Data, 1 Stop, Parity Space
7 Data, 2 Stop, Parity Mark
8 Data, 1 Stop Parity Mark
RS232 Handshaking
RS232 Handshaking allows control of data transmission from the scanner
using software commands from the host device. When RTS/CTS is
turned Off, no data flow control is used.
Flow Control, No Timeout: The scanner asserts RTS when it has data to
send, and will wait indefinitely for CTS to be asserted by the host.
Character-Based Flow Control, No Timeout: The scanner asserts RTS
when it has a character to send, and will wait indefinitely for CTS to be
asserted by the host
Two-Direction Flow Control: The scanner asserts RTS when it is OK for
the host to transmit. The host asserts CTS when it is OK for the device to
transmit.
Flow Control with Timeout: The scanner asserts RTS when it has data
be asserted by the host. If the delay time expires and CTS is not asserted,
the device transmit buffer is cleared and scanning may resume.
Character-Based Flow Control with Timeout: The scanner asserts RTS
2 - 27
Download from Www.Somanuals.com. All Manuals Search And Download.
and CTS is not asserted, the device transmit buffer is cleared and scanning
may resume.
Default = RTS/CTS Off.
Flow Control, No Timeout
Character-Based Flow Control,
No Timeout
Two-Direction Flow Control
Flow Control with Timeout
Character-Based Flow Control
with Timeout
* RTS/CTS Off
RS232 Timeout
When using Flow Control with Timeout, you must program the length of the
delay you want to wait for CTS from the host. Set the length (in millisec-
onds) for a timeout by scanning the bar code below, then setting the time-
out (from 1-5100 milliseconds) by scanning digits from the Programming
RS232 Timeout
XON/XOFF
Standard ASCII control characters can be used to tell the scanner to start
sending data (XON/XOFF On) or to stop sending data (XON/XOFF Off).
When the host sends the XOFF character (DC3, hex 13) to the scanner,
2 - 28
Download from Www.Somanuals.com. All Manuals Search And Download.
data transmission stops. To resume transmission, the host sends the XON
character (DC1, hex 11). Data transmission continues where it left off
when XOFF was sent. Default = XON/XOFF Off.
XON/XOFF On
* XON/XOFF Off
ACK/NAK
After transmitting data, the scanner waits for an ACK character (hex 06) or
a NAK character (hex 15) response from the host. If ACK is received, the
communications cycle is completed and the scanner looks for more bar
codes. If NAK is received, the last set of bar code data is retransmitted and
the scanner waits for ACK/NAK again. Turn on the ACK/NAK protocol by
scanning the ACK/NAK On bar code below. To turn off the protocol, scan
ACK/NAK Off. Default = ACK/NAK Off.
ACK/NAK On
* ACK/NAK Off
Communication Timeout
This allows you to set the length (in milliseconds) for a timeout for the host
ACK/NAK response. Scan the bar code below, then set the timeout (from
Communication Timeout
Timeout Retries
This setting limits the number of Communication Timeout retries. If the
Timeout Retries is set to 0, the transmission is terminated after the ini-
tial Communication Timeout. Scan the bar code below, then set the
2 - 29
Download from Www.Somanuals.com. All Manuals Search And Download.
number of retries (from 0-255) by scanning digits from the
ting.) Default = 0.
Timeout Retries
Communication Timeout Beeper
This selection programs the scanner to issue an error beep when a
communication timeout has occurred. The error beep sound is pro-
Off
* On
NAK Retries
This selection limits the number of NAK retries that can occur in ACK/NAK
mode. Scan the bar code below, then set the number of retries (from 0-
(5 is the recommended setting.) Default = 0, or disabled.
NAK Retries
2 - 30
Download from Www.Somanuals.com. All Manuals Search And Download.
Support BEL/CAN in ACK/NAK
This protocol responds to <BEL> and <CAN> commands when in ACK/
NAK mode. The scanner sounds an error tone when a <BEL> command is
sent from the host. <CAN> terminates the transmission. Default = BEL/
CAN Off.
BEL/CAN On
* BEL/CAN Off
RS232 Defaults
If you want the custom RS232 default settings restored to your scanner,
scan the RS232 Defaults bar code below. This resets the scanner to the
there are no custom defaults, it will reset the scanner to the factory default
settings. Any settings that have not been specified through the custom
defaults will be restored to the factory default settings.
RS232 Defaults
NCR Modifiers
NCR ACK/NAK
This is an NCR communication protocol for ACK/NAK processing. Default
= NCR ACK/NAK Off.
* NCR ACK/NAK Off
NCR ACK/NAK On
2 - 31
Download from Www.Somanuals.com. All Manuals Search And Download.
Block Check Character
When this selection is set to Transmit, the NCR Block Check Character
(BCC) is expected with incoming messages and transmitted with outgoing
messages. Default = Transmit.
* Transmit
Don’t Transmit
NCR Prefix
This selection allows you to program an NCR-specific prefix. Refer to the
equivalent for the characters you want for the NCR prefix (typically, 02 for
STX). Scan the bar code below, then set the hex number (from 0-FF) by
= 0.
NCR Prefix
NCR Suffix
This selection allows you to program an NCR-specific suffix. Refer to the
equivalent for the characters you want for the NCR suffix (typically, 03 for
ETX). Scan the bar code below, then set the hex number (from 0-FF) by
= 0.
NCR Suffix
2 - 32
Download from Www.Somanuals.com. All Manuals Search And Download.
NCR Prefix/Suffix
When set to Transmit, both the NCR prefix and suffix are transmitted with
bar codes. Usually, prefixes and suffixes are programmed using the Data
following commands override any other prefix/suffix settings. Default =
Don’t Transmit.
Transmit
* Don’t Transmit
NCR NOF (Not-on-File) Error
A scanner receives an NOF (Not on File) command from the POS when-
ever it cannot cross-reference the bar code to a price parameter. When set
for an NOF, and disables the scanner while the cashier looks up the price
manually. When set to Off, no sound is emitted for an NOF. Default = Off.
On
* Off
Scanner to Bioptic Communication
The following settings are used to set up communication between Honeywell
scanners and bioptic scanners.
Note: The scanner’s baud rate must be set to 38400 and the RS232 Timeout
must be set to 3000 in order to communicate with a bioptic scanner. See
further information.
2 - 33
Download from Www.Somanuals.com. All Manuals Search And Download.
Scanner-Bioptic Packet Mode
Packet Mode On must be scanned to set the scanner’s format so it is com-
patible with a bioptic scanner. Default = Packet Mode Off.
* Packet Mode Off
Packet Mode On
ACK/NAK
After transmitting data, the scanner waits for an ACK character (hex 06) or
a NAK character (hex 15) response from the host. If ACK is received, the
communications cycle is completed and the scanner looks for more bar
codes. If NAK is received, the last set of bar code data is retransmitted and
the scanner waits for ACK/NAK again. Turn on the ACK/NAK protocol by
scanning the ACK/NAK On bar code below. To turn off the protocol, scan
ACK/NAK Off. Default = ACK/NAK Off.
ACK/NAK On
* ACK/NAK Off
Communication Timeout
This allows you to set the length (in milliseconds) for a timeout for the host
ACK/NAK response. Scan the bar code below, then set the timeout (from
Communication Timeout
2 - 34
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Input/Output Settings
Power Up Beeper
The scanner can be programmed to beep when it’s powered up. Scan the Off
bar code(s) if you don’t want a power up beep. Default = Power Up Beeper On
- Scanner.
Power Up Beeper Off -
Scanner
* Power Up Beeper On -
Scanner
Beep on BEL Character
You may wish to force the scanner to beep upon a command sent from the host.
If you scan the Beep on BEL On bar code below, the scanner will beep every
time a BEL character is received from the host. Default = Beep on BEL Off.
*Beep on BEL Off
Beep on BEL On
3 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Good Read and Error Indicators
Beeper – Good Read
The beeper may be programmed On or Off in response to a good read.
Turning this option off, only turns off the beeper response to a good read
indication. All error and menu beeps are still audible. Default = Beeper -
Good Read On.
Beeper - Good Read Off
* Beeper - Good Read On
Beeper Volume – Good Read
The beeper volume codes modify the volume of the beep the scanner
emits on a good read. Default = High.
Low
Medium
* High
Off
3 - 2
Download from Www.Somanuals.com. All Manuals Search And Download.
Beeper Pitch – Good Read
The beeper pitch codes modify the pitch (frequency) of the beep the scan-
ner emits on a good read. Default = Medium.
Low (1600 Hz)
* Medium (2350 Hz)
High (4200 Hz)
Beeper - Transmit Order
The beeper transmit order determines when the good read beep occurs.
The scanner can be set to emit the good read beep either before or after
data transmission. Default = Before Transmission.
* Before Transmission
After Transmission
Beeper Pitch – Error
The beeper pitch codes modify the pitch (frequency) of the sound the scan-
ner emits when there is a bad read or error. Default = Razz.
* Razz (100 Hz)
Medium (2000 Hz)
High (4200 Hz)
3 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Beeper Duration – Good Read
The beeper duration codes modify the length of the beep the scanner emits
on a good read. Default = Normal.
* Normal Beep
Short Beep
Number of Beeps – Good Read
The number of beeps of a good read can be programmed from 1 - 9. The
same number of beeps will be applied to the beeper and LED in response
to a good read. For example, if you program this option to have five beeps,
there will be five beeps and five LED flashes in response to a good read.
The beeps and LED flashes are in sync with one another.
To change the number of beeps, scan the bar code below and then scan a
inside the back cover of this manual. Default = 1.
Number of Good Read Beeps/LED Flashes
Number of Beeps – Error
The number of beeps and LED flashes emitted by the scanner for a bad
read or error can be programmed from 1 - 9. For example, if you program
this option to have five error beeps, there will be five error beeps and five
LED flashes in response to an error.
3 - 4
Download from Www.Somanuals.com. All Manuals Search And Download.
LED Indicators
The green and red LEDs can be programmed to be On or Off and at different
brightness levels to indicate various scanner states. Use the following bar
codes to program the LED indicators.
LED Settings
Default = Red LED Off with Laser, Green LED On with Good Scan.
* Red LED Off
Green LED Off
Red LED On with Good Scan
* Green LED On with Good Scan
Red LED On with Laser
Green LED On with Laser
Red LED On when CodeGate
Disabled
Green LED On when CodeGate
Disabled
Red LED On when In-Stand
Green LED On when In-Stand
3 - 6
Download from Www.Somanuals.com. All Manuals Search And Download.
Red LED On with CTS
Green LED On with CTS
LED Brightness
Default = Red High, Green High.
Red Off
Red Low
Green Off
Green Low
Red Medium
Green Medium
* Red High
* Green High
In-Stand and Out-Of-Stand Settings
The following settings program the scanner’s behavior when it is either in the
stand, or out of the stand (hand-held).
3 - 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Caution: When working with In-Stand and Out-of-Stand settings, enable
the settings you want before disabling those you do not want to
use. If you disable settings first, you may program the scanner
so it is unable to read bar codes. if this happens, power cycle
In-Stand and Out-of-Stand Defaults
If you want the In-Stand or Out-of-Stand default settings restored to your
scanner, scan the appropriate Defaults bar code below. They reset the
factory default settings. Any settings that have not been specified through
the custom defaults will be defaulted to the factory default settings.
In-Stand Defaults
Out-of-Stand Defaults
Presentation Modes
When the scanner is in the stand, by default, bar codes are automatically
read when they are detected in the scanner’s field of view. When the scan-
ner is out of the stand, by default you must pull the trigger to read a bar
code. Use the following commands to adjust how the scanner behaves
when it is out of the stand.
Presentation Mode Out-of-Stand: When the scanner is not in the stand,
it automatically detects bar codes, then scans and transmits the data. The
laser turns off afterward. (If you are accustomed to a Voyager 9520, this
setting is the same as the 9520’s default.)
3 - 8
Download from Www.Somanuals.com. All Manuals Search And Download.
Presentation Mode with CodeGate® Out-of-Stand: When the scanner
is not in the stand, it automatically detects bar codes and decodes them.
However, the data is not transmitted until you pull the trigger. The laser
remains on briefly after the transmission. (If you are accustomed to a Voy-
ager 9540, this setting is the same as the 9540’s default.)
Presentation Mode
Out-of-Stand
Presentation Mode with
CodeGate Out-of-Stand
Manual Activation Mode
In Manual Activation Mode, you must pull the trigger to scan a bar code.
The scanner scans until a bar code is read, or until the trigger is released.
Default = Manual Activation Mode Off In-Stand, Manual Activation On Out-
of-Stand.
Manual Activation Mode Off
In-Stand
* Manual Activation Mode On
In-Stand
Manual Activation Mode Off
Out-of-Stand
* Manual Activation Mode On
Out-of-Stand
End Manual Activation After Good Read
After a bar code is successfully read, the laser can be programmed either
to remain on and scanning, or to turn off. When End Manual Activation
After Good Read is enabled, the laser turns off and stops scanning after a
3 - 9
Download from Www.Somanuals.com. All Manuals Search And Download.
good read. If you scan Do Not End Manual Activation After Good Read,
the laser remains on after a good read, but the trigger must be pressed to
scan the next bar code. Default = End Manual Activation After Good Read.
Do Not End Manual Activation
After Good Read In-Stand
* End Manual Activation After
Good Read In-Stand
Do Not End Manual Activation
After Good Read Out-of-Stand
* End Manual Activation After
Good Read Out-of-Stand
Manual Activation Laser Timeout -
Trigger Settings
You can set a timeout for the length of time the laser remains on and
attempting to decode bar codes when the trigger is held down, and after it
is released. Set the length (in milliseconds) for a timeout by scanning one
of the bar codes below, then setting the timeout (from 1-65535 millisec-
30000 ms, Trigger Release In or Out-of-Stand 0.
Laser Timeout - Trigger Hold
In-Stand
Laser Timeout - Trigger
Release In-Stand
Laser Timeout - Trigger Hold
Out-of-Stand
Laser Timeout - Trigger
Release Out-of-Stand
3 - 10
Download from Www.Somanuals.com. All Manuals Search And Download.
®
CodeGate
When CodeGate is On, the trigger is used to allow decoded data to be
transmitted to the host system. The scanner remains on, scanning and
decoding bar codes, but the bar code data is not transmitted until the trig-
ger is pressed. When CodeGate is Off, bar code data is transmitted when
it is decoded. Default = CodeGate Off in-Stand, CodeGate On Out-of-
Stand.
* CodeGate Off
In-Stand
CodeGate On
In-Stand
CodeGate Off
Out-of-Stand
* CodeGate On
Out-of-Stand
Object Detection Mode
Object Detection Mode uses an LED to detect when an object is in the
scanner’s field of view. When an object is detected, the laser turns on and
the scanner attempts to scan the bar code. Default = Object Detection
Mode On In-Stand.
Object Detection Mode Off
In-Stand
* Object Detection Mode On
In-Stand
* Object Detection Mode Off
Out-of-Stand
Object Detection Mode On
Out-of-Stand
3 - 11
Download from Www.Somanuals.com. All Manuals Search And Download.
End Object Detection After Good Read
After a bar code is successfully detected and read from the scanner, the
laser can be programmed either to remain on and scanning, or to turn off.
When End Object Detection After Good Read is enabled, the laser turns
off and stops scanning after a good read. If you scan Do Not End Object
Detection After Good Read, the laser remains on after a good read.
Default = End Object Detection After Good Read.
Do Not End Object Detection
After Good Read In-Stand
* End Object Detection After
Good Read In-Stand
Do Not End Object Detection
After Good Read Out-of-Stand
* End Object Detection After
Good Read Out-of-Stand
Object Detection Laser Timeout
You can set a timeout for the length of time the laser remains on and
attempting to decode bar codes after an object is detected. Set the length
(in milliseconds) for a timeout by scanning the bar code below, then setting
the timeout (from 1-65535 milliseconds) by scanning digits from the
Object Detection Laser
Timeout In-Stand
Object Detection Laser
Timeout Out-of-Stand
3 - 12
Download from Www.Somanuals.com. All Manuals Search And Download.
Object Detection Distance
When the scanner is in the stand and you are using Object Detection
Mode, you can set the distance range for detecting objects. Short sets the
scanner to detect objects approximately 5 inches (12.7cm) away from the
nose. Long sets it to detect objects approximately 10 inches (25.4cm)
away. Default = Short In-Stand, Long Out-of-Stand.
* Short
In-Stand
Long
In-Stand
Short
Out-of-Stand
* Long
Out-of-Stand
Character Activation Mode
You may use a character sent from the host to trigger the scanner to begin
scanning. When the activation character is received, the scanner continues
or a bar code is transmitted. Scan the On bar code below to use character acti-
vation, then use Activation Character (following) to select the character you will
send from the host to start scanning. Default = Off.
* Off
On
Activation Character
This sets the character used to trigger scanning when using Character Acti-
A-3, find the hex value that represents the character you want to use to trig-
3 - 13
Download from Www.Somanuals.com. All Manuals Search And Download.
to read the alphanumeric combination that represents that ASCII character.
Activation Character
End Character Activation After Good Read
After a bar code is successfully detected and read from the scanner, the
laser can be programmed either to remain on and scanning, or to turn off.
When End Character Activation After Good Read is enabled, the laser
turns off and stops scanning after a good read. If you scan Do Not End
Character Activation After Good Read, the laser remains on after a good
read. Default = End Character Activation After Good Read.
Do Not End Character Activation
After Good Read
* End Character Activation After
Good Read
Character Activation Laser Timeout
You can set a timeout for the length of time the laser remains on and
attempting to decode bar codes when using Character Activation Mode.
Set the length (in milliseconds) for a timeout by scanning the bar code
below, then setting the timeout (from 1-65535 milliseconds) by scanning
ms.
Character Activation Laser
Timeout
3 - 14
Download from Www.Somanuals.com. All Manuals Search And Download.
Character Deactivation Mode
If you have sent a character from the host to trigger the scanner to begin scan-
ning, you can also send a deactivation character to stop scanning. Scan the On
bar code below to use character deactivation, then use Deactivation Character
(following) to select the character you will send from the host to terminate scan-
ning. Default = Off.
* Off
On
Deactivation Character
This sets the character used to terminate scanning when using Character
page A-3, find the hex value that represents the character you want to use
to terminate scanning. Scan the bar code below, then use the
Programming Chart to read the alphanumeric combination that represents
Deactivation Character
3 - 15
Download from Www.Somanuals.com. All Manuals Search And Download.
Reread Delay
This sets the time period before the scanner can read the same bar code a sec-
ond time. Setting a reread delay protects against accidental rereads of the
same bar code. Longer delays are effective in minimizing accidental rereads.
Use shorter delays in applications where repetitive bar code scanning is
required. Default = Medium.
Short (500 ms)
* Medium (750 ms)
Long (1000 ms)
Extra Long (2000 ms)
User-Specified Reread Delay
If you want to set your own length for the reread delay, scan the bar code below,
then set the delay (from 0-30,000 milliseconds) by scanning digits from the
User-Specified Reread Delay
Output Sequence Overview
Require Output Sequence
When turned off, the bar code data will be output to the host as the scanner
decodes it. When turned on, all output data must conform to an edited
sequence or the scanner will not transmit the output data to the host
tion.
3 - 16
Download from Www.Somanuals.com. All Manuals Search And Download.
Output Sequence Editor
This programming selection allows you to program the scanner to output
data (when scanning more than one symbol) in whatever order your appli-
cation requires, regardless of the order in which the bar codes are
scanned. Reading the Default Sequence symbol programs the scanner to
the Universal values, shown below. These are the defaults. Be certain
you want to delete or clear all formats before you read the Default
Sequence symbol.
Note: If CodeGate is enabled, you must hold the trigger while reading each
bar code in a sequence.
Note: To make Output Sequence Editor selections, you’ll need to know the
code I.D., code length, and character match(es) your application
to read these options.
To Add an Output Sequence
2. Code I.D.
want to apply the output sequence format. Locate the Hex value for that
symbology and scan the 2 digit hex value from the Programming Chart
(inside back cover).
3. Length
Specify what length (up to 9999 characters) of data output will be
acceptable for this symbology. Scan the four digit data length from the
a universal number, indicating all lengths.) When calculating the length,
you must count any programmed prefixes, suffixes, or formatted
characters as part of the length (unless using 9999).
4. Character Match Sequences
the Hex value that represents the character(s) you want to match. Use
represents the ASCII characters. (99 is the Universal number,
indicating all characters.)
5. End Output Sequence Editor
Save to save your entries.
Other Programming Selections
•
Discard
This exits without saving any Output Sequence changes.
3 - 17
Download from Www.Somanuals.com. All Manuals Search And Download.
Output Sequence Example
In this example, you are scanning Code 93, Code 128, and Code 39 bar
codes, but you want the scanner to output Code 39 1st, Code 128 2nd, and
Code 93 3rd, as shown below.
Note: Code 93 must be enabled to use this example.
A - Code 39
B - Code 128
C - Code 93
You would set up the sequence editor with the following command line:
SEQBLK62999941FF6A999942FF69999943FF
The breakdown of the command line is shown below:
SEQBLKsequence editor start command
62
code identifier for Code 39
9999
41
code length that must match for Code 39, 9999 = all lengths
start character match for Code 39, 41h = “A”
termination string for first code
FF
6A
code identifier for Code 128
9999
42
code length that must match for Code 128, 9999 = all lengths
start character match for Code 128, 42h = “B”
termination string for second code
FF
69
code identifier for Code 93
9999
43
code length that must match for Code 93, 9999 = all lengths
start character match for Code 93, 43h = “C”
termination string for third code
FF
To program the previous example using specific lengths, you would have to
count any programmed prefixes, suffixes, or formatted characters as part of
fix and specific code lengths, you would use the following command line:
SEQBLK62001241FF6A001342FF69001243FF
The breakdown of the command line is shown below:
3 - 18
Download from Www.Somanuals.com. All Manuals Search And Download.
SEQBLKsequence editor start command
62
code identifier for Code 39
0012
41
A - Code 39 sample length (11) plus CR suffix (1) = 12
start character match for Code 39, 41h = “A”
termination string for first code
FF
6A
code identifier for Code 128
0013
42
B - Code 128 sample length (12) plus CR suffix (1) = 13
start character match for Code 128, 42h = “B”
termination string for second code
FF
69
code identifier for Code 93
0012
43
C - Code 93 sample length (11) plus CR suffix (1) = 12
start character match for Code 93, 43h = “C”
termination string for third code
FF
Output Sequence Editor
Enter Sequence
Default Sequence
Sequence Timeout
You may wish to set the maximum time between bar code scans in an out-
put sequence. If that maximum time is not met, the output sequence oper-
ation is terminated. Set the length (in milliseconds) for a timeout by
scanning the bar code below, then setting the timeout (from 1-65535 milli-
Sequence Timeout
3 - 19
Download from Www.Somanuals.com. All Manuals Search And Download.
Sequence Match Beeper
By default, the scanner beeps when a sequence match is found. If you
want the scanner to remain silent, scan the Sequence Match Beeper Off
bar code below. Default = Sequence Match Beeper On.
Sequence Match Beeper Off
* Sequence Match Beeper On
Partial Sequence
If an output sequence operation is terminated before all your output
sequence criteria are met, the bar code data acquired to that point is a
“partial sequence.”
Scan Discard Partial Sequence to discard partial sequences when the
output sequence operation is terminated before completion.
Scan Transmit Partial Sequence to transmit partial sequences. (Any
fields in the sequence where no data match occurred will be skipped in the
the timeout is reached, the partial sequence is transmitted. Default = Dis-
card Partial Sequence.
Transmit Partial Sequence
* Discard Partial Sequence
Require Output Sequence
When an output sequence is Required, all output data must conform to an
edited sequence or the scanner will not transmit the output data to the host
device. When it’s On/Not Required, the scanner will attempt to get the
output data to conform to an edited sequence but, if it cannot, the scanner
transmits all output data to the host device as is.
3 - 20
Download from Www.Somanuals.com. All Manuals Search And Download.
When the output sequence is Off, the bar code data is output to the host as
the scanner decodes it. Default = Off.
Required
On/Not Required
*Off
No Read
With No Read turned On, the scanner notifies you if a code cannot be read. If
appears when a code cannot be read. If No Read is turned Off, the “NR” will
not appear. Default = Off.
On
* Off
If you want a different notation than “NR,” for example, “Error,” or “Bad Code,”
The hex code for the No Read symbol is 9C.
3 - 21
Download from Www.Somanuals.com. All Manuals Search And Download.
3 - 22
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Data Editing
Prefix/Suffix Overview
When a bar code is scanned, additional information is sent to the host computer
along with the bar code data. This group of bar code data and additional,
user-defined data is called a “message string.” The selections in this section
are used to build the user-defined data into the message string.
Prefix and Suffix characters are data characters that can be sent before and
after scanned data. You can specify if they should be sent with all symbologies,
or only with specific symbologies. The following illustration shows the break-
down of a message string:
Prefix
Scanned Data
Suffix
1-11
variable length
1-11
alpha numeric &
alpha numeric &
control characters
control characters
Points to Keep In Mind
•
It is not necessary to build a message string. The selections in this
chapter are only used if you wish to alter the default settings. Default
prefix = None. Default suffix is dependent on interface.
•
•
•
•
•
A prefix or suffix may be added or cleared from one symbology or all
symbologies.
You can add any prefix or suffix from the ASCII Conversion Chart (Code
You can string together several entries for several symbologies at one
time.
Enter prefixes and suffixes in the order in which you want them to appear
on the output.
When setting up for specific symbologies (as opposed to all
symbologies), the specific symbology ID value counts as an added prefix
or suffix character.
•
The maximum size of a prefix or suffix configuration is 32 characters,
which includes header information.
To Add a Prefix or Suffix:
Step 2. Determine the 2 digit Hex value from the Symbology Chart
4 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
symbology to which you want to apply the prefix or suffix. For
example, for Code 128, Code ID is “j” and Hex ID is “6A”.
cover of this manual or scan 9, 9 for all symbologies.
back cover of this manual.
Step 6. Repeat Steps 4 and 5 for every prefix or suffix character.
Step 7. To add the Code I.D., scan 5, C, 8, 0.
To add AIM I.D., scan 5, C, 8, 1.
To add a backslash (\), scan 5, C, 5, C.
Note: To add a backslash (\) as in Step 7, you must scan 5C twice – once
to create the leading backslash and then to create the backslash
itself.
Repeat Steps 1-6 to add a prefix or suffix for another symbology.
Example: Add a Suffix to a specific symbology
To send a CR (carriage return)Suffix for U.P.C. only:
Step 1. Scan Add Suffix.
Step 2. Determine the 2 digit hex value from the Symbology Chart
U.P.C.
manual.
manual.
To Clear One or All Prefixes or Suffixes
You can clear a single prefix or suffix, or clear all prefixes/suffixes for a
symbology. If you have been entering prefixes and suffixes for single sym-
bologies, you can use Clear One Prefix (Suffix) to delete a specific char-
acter from a symbology. When you Clear All Prefixes (Suffixes), all the
prefixes or suffixes for a symbology are deleted.
4 - 2
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 1. Scan the Clear One Prefix or Clear One Suffix symbol.
Step 2. Determine the 2 digit Hex value from the Symbology Chart
symbology from which you want to clear the prefix or suffix.
back cover of this manual or scan 9, 9 for all symbologies.
Your change is automatically saved.
To Add a Carriage Return Suffix to
All Symbologies
Scan the following bar code if you wish to add a carriage return suffix to all
symbologies at once. This action first clears all current suffixes, then pro-
grams a carriage return suffix for all symbologies.
Add CR Suffix
All Symbologies
Prefix Selections
Add Prefix
Clear One Prefix
Clear All Prefixes
4 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Suffix Selections
Add Suffix
Clear One Suffix
Clear All Suffixes
Transmit Alternate Extended ASCII Characters
You may need to emulate special keyboard functions, such as up or down
arrows, Alt/Make or Alt/Break commands, that are not supported in the
decimal and hex characters. If you scan the Transmit Alternate Extended
ASCII code, any hex entries in a prefix or suffix will result in the corresponding
Keyboard Function output.
Example: Transmit Alternate Extended ASCII is enabled, and you scan Add
Suffix, then scan 9 9 8 9. All symbologies (99) would have a suffix
of a Page Down (hex 89) added to them.
When Transmit Normal Extended ASCII is selected, the normal extended
Example: Transmit Normal Extended ASCII is enabled, and you scan Add
Suffix, then scan 9 9 8 9. All symbologies (99) would have a suffix
of a ‰ character added to them.
Default = Transmit Alternate Extended ASCII.
* Transmit Alternate Extended
ASCII
Transmit Normal Extended
ASCII
4 - 4
Download from Www.Somanuals.com. All Manuals Search And Download.
Alternate Extended ASCII Characters
DEC HEX Keyboard Function
DEC HEX Keyboard Function
128 80
129 81
130 82
131 83
152 98 F9
153 99 F10
154 9A F11
155 9B F12
up arrow ↑
down arrow ↓
right arrow →
left arrow ←
Insert
Delete
Home
End
Page Up
Page Down
Right ALT
Right CTRL
Reserved
Reserved
Numeric Keypad Enter
Numeric Keypad /
F1
F2
F3
F4
F5
F6
F7
F8
132 84
133 85
134 86
135 87
136 88
137 89
138 8A
139 8B
140 8C
141 8D
142 8E
143 8F
144 90
145 91
146 92
147 93
148 94
149 95
150 96
151 97
156 9C Numeric Keypad +
157 9D Numeric Keypad -
158 9E Numeric Keypad *
159 9F Caps Lock
160 A0 Num Lock
161 A1 Left Alt
162 A2 Left Ctrl
163 A3 Left Shift
164 A4 Right Shift
165 A5 Print Screen
166 A6 Tab
167 A7 Shift Tab
168 A8 Enter
169 A9 Esc
170 AA Alt Make
171 AB Alt Break
172 AC Control Make
173 AD Control Break
174 AE Alt Sequence with 1 Character
175 AF Ctrl Sequence with 1 Character
4 - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Function Code Transmit
When this selection is enabled and function codes are contained within the
scanned data, the scanner transmits the function code to the terminal. Charts
verted to a key code before it is transmitted. Default = Enable.
* Enable
Disable
Communication Check Character
To enhance security, you can specify the transmission type of a check charac-
ter; either LRC where the calculation starts on the first transmitted character,
LRC where the calculation starts on the second transmitted character, or CRC.
Note: This option adds a check character to the bar code data for all
symbologies. If you need to enable or disable check characters for
Scan the bar code below to set the communication check character type.
Default = None.
* None
LRC Starts on 1st Character
LRC Starts on 2nd Character
CRC
4 - 6
Download from Www.Somanuals.com. All Manuals Search And Download.
Intercharacter, Interfunction, and
Intermessage Delays
Some terminals drop information (characters) if data comes through too quickly.
Intercharacter, interfunction, and intermessage delays slow the transmission of
data, increasing data integrity.
Intercharacter Delay
An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may
be placed between the transmission of each character of scanned data.
Scan the Intercharacter Delay bar code below, then scan the number of
the back cover of this manual.
Prefix
Scanned Data
Suffix
1
2
3
4
5
Intercharacter Delay
Intercharacter Delay
To remove this delay, scan the Intercharacter Delay bar code, then set the
Chart inside the back cover of this manual.
Note: Intercharacter delays are not supported in USB serial emulation.
User Specified Intercharacter Delay
An intercharacter delay of up to 5000 milliseconds (in 5ms increments)
may be placed after the transmission of a particular character of scanned
data. Scan the Delay Length bar code below, then scan the number of
the back cover of this manual.
4 - 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Next, scan the Character to Trigger Delay bar code, then the 2-digit hex
value for the ASCII character that will trigger the delay ASCII Conversion
Delay Length
Character to Trigger Delay
To remove this delay, scan the Delay Length bar code, and set the number
inside the back cover of this manual.
Interfunction Delay
An interfunction delay of up to 5000 milliseconds (in 5ms increments) may
be placed between the transmission of each segment of the message
string. Scan the Interfunction Delay bar code below, then scan the num-
inside the back cover of this manual.
Prefix
STX
Scanned Data
3 4
Interfunction Delays
Suffix
1
HT
2
5
CR
LF
Interfunction Delay
To remove this delay, scan the Interfunction Delay bar code, then set the
Chart inside the back cover of this manual.
4 - 8
Download from Www.Somanuals.com. All Manuals Search And Download.
Intermessage Delay
An intermessage delay of up to 5000 milliseconds (in 5ms increments)
may be placed between each scan transmission. Scan the Intermessage
ual.
1st Scan Transmission
2nd Scan Transmission
Intermessage Delay
Intermessage Delay
To remove this delay, scan the Intermessage Delay bar code, then set the
Chart inside the back cover of this manual.
4 - 9
Download from Www.Somanuals.com. All Manuals Search And Download.
4 - 10
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Data Formatting
Data Format Editor Introduction
You may use the Data Format Editor to change the scanner’s output. For exam-
ple, you can use the Data Format Editor to insert characters at certain points in
bar code data as it is scanned. The selections in the following pages are used
only if you wish to alter the output. Default Data Format setting = None.
Normally, when you scan a bar code, it gets outputted automatically; however
Multiple formats may be programmed into the scanner. They are stacked in the
order in which they are entered. However, the following list presents the order
in which formats are applied:
1. Specific Terminal ID, Actual Code ID, Actual Length
2. Specific Terminal ID, Actual Code ID, Universal Length
3. Specific Terminal ID, Universal Code ID, Actual Length
4. Specific Terminal ID, Universal Code ID, Universal Length
5. Universal Terminal ID, Actual Code ID, Actual Length
6. Universal Terminal ID, Actual Code ID, Universal Length
7. Universal Terminal ID, Universal Code ID, Actual Length
8. Universal Terminal ID, Universal Code ID, Universal Length
The maximum size of a data format configuration is 256 bytes, which includes
header information. No format can contain more than 50 bytes.
If you have changed data format settings, and wish to clear all formats and
return to the factory defaults, scan the Default Data Format code below.
* Default Data Format
To Add a Data Format
Step 2. Select Primary/Alternate Format
Determine if this will be your primary data format, or one of 3 alternate
formats. This allows you to save a total of 4 different data formats. To
inside the back cover of this manual. If you are programming an
alternate format, scan 1, 2, or 3, depending on which alternate format
5 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
5-10 for further information.)
Step 3. Terminal Type
number for your PC. Scan three numeric bar codes on the
Programming Chart to program the scanner for your terminal ID (you
must enter 3 digits). For example, scan 0 0 3 for an AT wedge.
Note: The wildcard for all terminal types is 099.
Step 4. Code I.D.
which you want to apply the data format. Locate the Hex value for that
symbology and scan the 2 digit hex value from the Programming Chart
inside the back cover of this manual.
Step 5. Length
Specify what length (up to 9999 characters) of data will be acceptable
for this symbology. Scan the four digit data length from the
characters is entered as 0050. 9999 is a universal number, indicating
all lengths.)
Step 6. Editor Commands
want to enter. 94 alphanumeric characters may be entered for each
symbology data format.
Step 7. Scan Save to save your data format, or Discard to exit without saving
your changes.
Enter Data Format
Save
Discard
5 - 2
Download from Www.Somanuals.com. All Manuals Search And Download.
Other Programming Selections
Clear One Data Format
This deletes one data format for one symbology. If you are clearing the
cover of this manual. If you are clearing an alternate format, scan 1, 2,
or 3, depending on the format you are clearing. Scan the Terminal Type
data length for the specific data format that you want to delete. All other
formats remain unaffected.
Clear all Data Formats
This clears all data formats.
Save to exit and save your data format changes.
Discard to exit without saving any data format changes.
Clear One Data Format
Clear All Data Formats
Save
Discard
5 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Terminal ID Table
Terminal
ID
Terminal
Model(s)
IBM
PC/AT and compatibles
PS2 Keyboard
USB SurePOS Handheld
Scanner
003
002
128
USB SurePOS Tabletop
Scanner
129
RS232
True
TTL
000
000
051
130
124
125
134
131
RS485
USB
Serial
PC Keyboard
Mac Keyboard
Japanese Keyboard (PC)
HID POS
Data Format Editor Commands
Send Commands
Send all characters
F1 Include in the output message all of the characters from the input
message, starting from current cursor position, followed by an insert
character. Syntax = F1xx where xx stands for the insert character’s hex
value for its ASCII code.
for decimal, hex and character codes.
Send a number of characters
F2 Include in the output message a number of characters followed by an
insert character. Start from the current cursor position and continue for
“nn” characters or through the last character in the input message,
followed by character “xx.” Syntax = F2nnxx where nn stands for the
numeric value (00-99) for the number of characters, and xx stands for
the insert character’s hex value for its ASCII code.
for decimal, hex and character codes.
5 - 4
Download from Www.Somanuals.com. All Manuals Search And Download.
Send all characters up to a particular character
F3 Include in the output message all characters from the input message,
starting with the character at the current cursor position and continuing
to, but not including, the search character “ss,” followed by an insert
character. The cursor is moved forward to the “ss” character. Syntax
= F3ssxx where ss stands for the search character’s hex value for its
ASCII code, and xx stands for the insert character’s hex value for its
ASCII code.
decimal, hex and character codes.
Send all but the last characters
E9 Include in the output message all but the last “nn” characters, starting
from the current cursor position. The cursor is moved forward to one
position past the last input message character included. Syntax = E9nn
where nn stands for the numeric value (00-99) for the number of
characters that will not be sent at the end of the message.
Insert a character multiple times
F4 Send “xx” character “nn” times in the output message, leaving the
cursor in the current position. Syntax = F4xxnn where xx stands for the
insert character’s hex value for its ASCII code, and nn is the numeric
value (00-99) for the number of times it should be sent.
decimal, hex and character codes.
Insert symbology name
B3 Insert the name of the bar code’s symbology in the output message,
without moving the cursor. Only symbologies with a Honeywell ID are
decimal, hex and character codes.
Insert bar code length
B4 Insert the bar code’s length in the output message, without moving the
cursor. The length is expressed as a numeric string and does not
include leading zeroes.
Move Commands
Move the cursor forward a number of characters
F5 Move the cursor ahead “nn” characters from current cursor position.
Syntax = F5nn where nn is the numeric value (00-99) for the number
of characters the cursor should be moved ahead.
Move the cursor backward a number of characters
F6 Move the cursor back “nn” characters from current cursor position.
Syntax = F6nn where nn is the numeric value (00-99) for the number
of characters the cursor should be moved back.
5 - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Move the cursor to the beginning
F7 Move the cursor to the first character in the input message. Syntax =
F7.
Move the cursor to the end
EA Move the cursor to the last character in the input message. Syntax =
EA.
Search Commands
Search forward for a character
F8 Search the input message forward for “xx” character from the current
cursor position, leaving the cursor pointing to the “xx” character.
Syntax = F8xx where xx stands for the search character’s hex value for
its ASCII code.
for decimal, hex and character codes.
Search backward for a character
F9 Search the input message backward for “xx” character from the current
cursor position, leaving the cursor pointing to the “xx” character.
Syntax = F9xx where xx stands for the search character’s hex value for
its ASCII code.
for decimal, hex and character codes.
Search forward for a string
B0 Search forward for “s” string from the current cursor position, leaving
cursor pointing to “s” string. Syntax = B0nnnnS where nnnn is the string
length (up to 9999), and S consists of the ASCII hex value of each
character in the match string. For example, B0000454657374 will
search forward for the first occurrence of the 4 character string “Test.”
for decimal, hex and character codes.
Search backward for a string
B1 Search backward for “s” string from the current cursor position, leaving
cursor pointing to “s” string. Syntax = B1nnnnS where nnnn is the string
length (up to 9999), and S consists of the ASCII hex value of each
character in the match string. For example, B1000454657374 will
search backward for the first occurrence of the 4 character string “Test.”
for decimal, hex and character codes.
5 - 6
Download from Www.Somanuals.com. All Manuals Search And Download.
Search forward for a non-matching character
E6 Search the input message forward for the first non-“xx” character from
the current cursor position, leaving the cursor pointing to the non-“xx”
character. Syntax = E6xx where xx stands for the search character’s
hex value for its ASCII code.
decimal, hex and character codes.
Search backward for a non-matching character
E7 Search the input message backward for the first non-“xx” character
from the current cursor position, leaving the cursor pointing to the non-
“xx” character. Syntax = E7xx where xx stands for the search
character’s hex value for its ASCII code.
decimal, hex and character codes.
Miscellaneous Commands
Suppress characters
FB Suppress all occurrences of up to 15 different characters, starting at the
current cursor position, as the cursor is advanced by other commands.
When the FC command is encountered, the suppress function is
terminated. The cursor is not moved by the FB command.
Syntax = FBnnxxyy . .zz where nn is a count of the number of
suppressed characters in the list, and xxyy .. zz is the list of characters
to be suppressed.
Stop suppressing characters
FC Disables suppress filter and clear all suppressed characters. Syntax =
FC.
Replace characters
E4 Replaces up to 15 characters in the output message, without moving
the cursor. Replacement continues until the E5 command is
encountered. Syntax = E4nnxx xx yy yy ...zz zz where nn is the total
1
2
1
2
1
2
count of the number of characters in the list (characters to be replaced
plus replacement characters); xx defines characters to be replaced
1
and xx defines replacement characters, continuing through zz and
2
1
zz .
2
Stop replacing characters
E5 Terminates character replacement. Syntax = E5.
5 - 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Compare characters
FE Compare the character in the current cursor position to the character
“xx.” If characters are equal, move the cursor forward one position.
Syntax = FExx where xx stands for the comparison character’s hex
value for its ASCII code.
for decimal, hex and character codes.
Compare string
B2 Compare the string in the input message to the string “s.” If the strings
are equal, move the cursor forward past the end of the string. Syntax
= B2nnnnS where nnnn is the string length (up to 9999), and S consists
of the ASCII hex value of each character in the match string. For
example, B2000454657374 will compare the string at the current
cursor position with the 4 character string “Test.”
for decimal, hex and character codes.
Check for a number
EC Check to make sure there is an ASCII number at the current cursor
position. The format is aborted if the character is not numeric.
Check for non-numeric character
ED Check to make sure there is a non-numeric ASCII character at the
current cursor position. The format is aborted if the character is
numeric.
Insert a delay
EF Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting
from the current cursor position. Syntax = EFnnnn where nnnn stands
for the delay in 5ms increments, up to 9999. This command can only
be used with keyboard wedge interfaces.
Data Formatter
When Data Formatter is turned Off, the bar code data is output to the host as
read, including prefixes and suffixes.
Data Formatter Off
You may wish to require the data to conform to a data format you have created
and saved. The following settings can be applied to your data format:
Data Formatter On, Not Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and
suffixes are transmitted.
5 - 8
Download from Www.Somanuals.com. All Manuals Search And Download.
Data Formatter On, Not Required, Drop Prefix/Suffix
Scanned data is modified according to your data format. If a data format is
found for a particular symbol, those prefixes and suffixes are not
transmitted.
Data Format Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and
suffixes are transmitted. Any data that does not match your data format
requirements generates an error tone and the data in that bar code is not
transmitted. If you wish to process this type of bar code without generating
Data Format Required, Drop Prefix/Suffix
Scanned data is modified according to your data format. If a data format is
found for a particular symbol, those prefixes and suffixes are not
transmitted. Any data that does not match your data format requirements
generates an error tone. If you wish to process this type of bar code without
Choose one of the following options. Default = Data Formatter On, Not
Required, Keep Prefix/Suffix.
* Data Formatter On,
Not Required,
Keep Prefix/Suffix
Data Formatter On,
Not Required,
Drop Prefix/Suffix
Data Format Required,
Keep Prefix/Suffix
Data Format Required,
Drop Prefix/Suffix
Data Format Non-Match Error Tone
When a bar code is encountered that doesn’t match your required data for-
mat, the scanner normally generates an error tone. However, you may
want to continue scanning bar codes without hearing the error tone. If you
scan the Data Format Non-Match Error Tone Off bar code, data that
doesn’t conform to your data format is not transmitted, and no error tone
5 - 9
Download from Www.Somanuals.com. All Manuals Search And Download.
will sound. If you wish to hear the error tone when a non-matching bar
code is found, scan the Data Format Non-Match Error Tone On bar code.
Default = Data Format Non-Match Error Tone On.
* Data Format Non-Match Error
Tone On
Data Format Non-Match
Error Tone Off
Primary/Alternate Data Formats
You can save up to four data formats, and switch between these formats. Your
primary data format is saved under 0. Your other three formats are saved under
1, 2, and 3. To set your device to use one of these formats, scan one of the bar
codes below.
Primary Data Format
Data Format 1
Data Format 2
Data Format 3
Single Scan Data Format Change
You can also switch between data formats for a single scan. The next bar
code is scanned using an alternate data format, then reverts to the format
you have selected above (either Primary, 1, 2, or 3).
5 - 10
Download from Www.Somanuals.com. All Manuals Search And Download.
For example, you may have set your device to the data format you saved as
Data Format 3. You can switch to Data Format 1 for a single trigger pull by
scanning the Single Scan-Data Format 1 bar code below. The next bar
code that is scanned uses Data Format 1, then reverts back to Data Format
3.
Single Scan-Primary
Data Format
Single Scan-Data Format 1
Single Scan-Data Format 2
Single Scan-Data Format 3
5 - 11
Download from Www.Somanuals.com. All Manuals Search And Download.
5 - 12
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Symbologies
This programming section contains the following menu selections. Refer to
Chapter 9 for settings and defaults.
•
•
•
•
Airline Code 5 - see Straight 2 of 5
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
All Symbologies
If you want to decode all the symbologies allowable for your scanner, scan the
All Symbologies On code. If on the other hand, you want to decode only a
particular symbology, scan All Symbologies Off followed by the On symbol for
that particular symbology.
All Symbologies On
All Symbologies Off
6 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Message Length Description
You are able to set the valid reading length of some of the bar code symbolo-
gies. If the data length of the scanned bar code doesn’t match the valid read-
ing length, the scanner will issue an error tone. You may wish to set the same
value for minimum and maximum length to force the scanner to read fixed
length bar code data. This helps reduce the chances of a misread.
EXAMPLE: Decode only those bar codes with a count of 9-20 characters.
Min. length = 09Max. length = 20
EXAMPLE: Decode only those bar codes with a count of 15 characters.
Min. length = 15Max. length = 15
For a value other than the minimum and maximum message length defaults,
scan the bar codes included in the explanation of the symbology, then scan the
lengths and the defaults are included with the respective symbologies.
6 - 2
Download from Www.Somanuals.com. All Manuals Search And Download.
Codabar
<Default All Codabar Settings>
Codabar On/Off
* On
Off
Codabar Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the bar code.
You may either transmit, or not transmit Start/Stop characters.
Default = Don’t Transmit.
Transmit
* Don’t Transmit
Codabar Check Character
Codabar check characters are created using different “modulos.” You can
program the scanner to read only Codabar bar codes with Modulo 16, Mod-
ulo 7 CD, or CLSI check characters. Default = No Check Character.
No Check Character indicates that the scanner reads and transmits bar
code data with or without a check character.
When Check Character is set to Validate and Transmit, the scanner will
only read Codabar bar codes printed with a check character, and will trans-
mit this character at the end of the scanned data.
6 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
When Check Character is set to Validate, but Don’t Transmit, the unit will
only read Codabar bar codes printed with a check character, but will not
transmit the check character with the scanned data.
* No Check Character
Validate Modulo 16, but
Don’t Transmit
Validate Modulo 16
and Transmit
Validate Modulo 7 CD, but Don’t
Transmit
Validate Modulo 7 CD and
Transmit
Validate CLSI, but Don’t
Transmit
Validate CLSI and Transmit
Codabar Concatenation
Codabar supports symbol concatenation. When you enable concatena-
tion, the scanner looks for a Codabar symbol having a “D” start character,
adjacent to a symbol having a “D” stop character. In this case the two mes-
sages are concatenated into one with the “D” characters omitted.
A 1 2 3 4 D D 5 6 7 8 A
6 - 4
Download from Www.Somanuals.com. All Manuals Search And Download.
Select Require to prevent the scanner from decoding a single “D” Codabar
symbol without its companion. This selection has no effect on Codabar
symbols without Stop/Start D characters.
On
* Off
Require
Concatenation Timeout
When searching for bar codes during concatenation, you may wish to
set a delay used to find the next bar code. Set the length (in millisec-
onds) for this delay by scanning the bar code below, then setting the
timeout (from 1-65535 milliseconds) by scanning digits from the
Concatenation Timeout
Codabar Redundancy
If you are encountering errors when reading Codabar bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the Cod-
abar Redundancy bar code below, then scan a redundancy count
Codabar Redundancy
6 - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 39
< Default All Code 39 Settings >
Code 39 On/Off
* On
Off
Code 39 Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the bar code.
You may either transmit, or not transmit Start/Stop characters. Default =
Don’t Transmit.
Transmit
* Don’t Transmit
Code 39 Check Character
No Check Character indicates that the scanner reads and transmits bar
code data with or without a check character.
When Check Character is set to Validate, but Don’t Transmit, the unit
only reads Code 39 bar codes printed with a check character, but will not
transmit the check character with the scanned data.
6 - 7
Download from Www.Somanuals.com. All Manuals Search And Download.
When Check Character is set to Validate and Transmit, the scanner only
reads Code 39 bar codes printed with a check character, and will transmit
this character at the end of the scanned data. Default = No Check Charac-
ter.
* No Check Character
Validate, but Don’t Transmit
Validate and Transmit
Code 39 Redundancy
If you are encountering errors when reading Code 39 bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the Code
39 Redundancy bar code below, then scan a redundancy count between 0
Code 39 Redundancy
Code 39 Message Length
Scan the bar codes below to change the message length. Refer to
mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
6 - 8
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 32 Pharmaceutical (PARAF)
Code 32 Pharmaceutical is a form of the Code 39 symbology used by Ital-
ian pharmacies. This symbology is also known as PARAF.
On
* Off
Full ASCII
If Full ASCII Code 39 decoding is enabled, certain character pairs within
the bar code symbol will be interpreted as a single character. For example:
$V will be decoded as the ASCII character SYN, and /C will be decoded as
the ASCII character #. Default = Off.
NUL %U
SOH $A
STX $B
ETX $C
EOT $D
ENQ $E
ACK $F
BEL $G
BS $H
HT $I
DLE $P
DC1 $Q
DC2 $R
DC3 $S
DC4 $T
NAK $U
SYN $V
ETB $W
CAN $X
EM $Y
SUB $Z
ESC %A
FS %B
GS %C
RS %D
US %E
SP
!
SPACE
/A
/B
/C
/D
/E
/F
/G
/H
/I
0
1
2
3
4
5
6
7
8
9
:
0
@
A
B
C
D
E
F
%V
A
B
C
D
E
F
P
Q
R
S
T
U
V
W
X
Y
Z
[
P
‘
%W
+A
+B
+C
+D
+E
+F
+G
+H
+I
p
q
r
+P
+Q
+R
+S
+T
1
Q
a
b
c
d
e
f
“
2
R
#
$
%
&
‘
3
S
s
t
4
T
5
U
u
v
w
x
y
z
{
+U
+V
+W
+X
+Y
+Z
6
V
7
G
H
I
G
H
I
W
X
g
h
i
(
8
)
9
Y
LF $J
VT $K
FF $L
CR $M
SO $N
*
/J
/Z
%F
%G
%H
%I
%J
J
J
Z
j
+J
+
,
/K
/L
;
K
L
K
L
%K
%L
%M
%N
%O
k
l
+K
+L
%P
%Q
%R
%S
<
=
>
?
\
|
-
-
M
N
O
M
N
O
]
m
n
o
+M
+N
}
.
.
^
~
SI
$O
/
/O
_
+O DEL %T
6 - 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Character pairs /M and /N decode as a minus sign and period respectively.
Character pairs /P through /Y decode as 0 through 9.
Full ASCII On
* Full ASCII Off
Interleaved 2 of 5
< Default All Interleaved 2 of 5 Settings >
Interleaved 2 of 5 On/Off
* On
Off
NULL Characters
Interleaved 2 of 5 requires an even number of characters. When an odd
number of characters is present, it is due to NULL characters embedded in
the bar code. Scan the On bar code below to decode this type of Inter-
leaved 2 of 5 bar code. Default = Off.
* Off
On
6 - 10
Download from Www.Somanuals.com. All Manuals Search And Download.
Check Digit
No Check Digit indicates that the scanner reads and transmits bar code
data with or without a check digit.
When Check Digit is set to Validate, but Don’t Transmit, the unit only
reads Interleaved 2 of 5 bar codes printed with a check digit, but will not
transmit the check digit with the scanned data.
When Check Digit is set to Validate and Transmit, the scanner only reads
Interleaved 2 of 5 bar codes printed with a check digit, and will transmit this
digit at the end of the scanned data. Default = No Check Digit.
* No Check Digit
Validate, but Don’t Transmit
Validate and Transmit
Interleaved 2 of 5 Redundancy
If you are encountering errors when reading Interleaved 2 of 5 bar codes,
you may want to adjust the redundancy count. Redundancy adjusts the
number of times a bar code is decoded before transmission, which may
reduce the number of errors. Note that the higher the redundancy count,
the longer it will take to decode the bar code. To adjust the redundancy,
scan the Interleaved 2 of 5 Redundancy bar code below, then scan a
Interleaved 2 of 5 Redundancy
6 - 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Interleaved 2 of 5 Message Length
Scan the bar codes below to change the message length. Refer to
mum and Maximum lengths = 1-80. Minimum Default = 6, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
NEC 2 of 5
< Default All NEC 2 of 5 Settings >
NEC 2 of 5 On/Off
On
* Off
Check Digit
No Check Digit indicates that the scanner reads and transmits bar code
data with or without a check digit.
When Check Digit is set to Validate, but Don’t Transmit, the unit only
reads NEC 2 of 5 bar codes printed with a check digit, but will not transmit
the check digit with the scanned data.
6 - 12
Download from Www.Somanuals.com. All Manuals Search And Download.
When Check Digit is set to Validate and Transmit, the scanner only reads
NEC 2 of 5 bar codes printed with a check digit, and will transmit this digit
at the end of the scanned data. Default = No Check Digit.
* No Check Digit
Validate, but Don’t Transmit
Validate and Transmit
NEC 2 of 5 Redundancy
If you are encountering errors when reading NEC 2 of 5 bar codes, you
may want to adjust the redundancy count. Redundancy adjusts the num-
ber of times a bar code is decoded before transmission, which may reduce
the number of errors. Note that the higher the redundancy count, the lon-
ger it will take to decode the bar code. To adjust the redundancy, scan the
NEC 2 of 5 Redundancy bar code below, then scan a redundancy count
NEC 2 of 5 Redundancy
NEC 2 of 5 Message Length
Scan the bar codes below to change the message length. Refer to
mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
6 - 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 93
< Default All Code 93 Settings >
Code 93 On/Off
* On
Off
Code 93 Redundancy
If you are encountering errors when reading Code 93 bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the Code
93 Redundancy bar code below, then scan a redundancy count between 0
Code 93 Redundancy
6 - 14
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 93 Message Length
Scan the bar codes below to change the message length. Refer to
mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
Straight 2 of 5 Industrial (three-bar start/stop)
<Default All Straight 2 of 5 Industrial Settings>
Straight 2 of 5 Industrial On/Off
On
* Off
Straight 2 of 5 Industrial Redundancy
If you are encountering errors when reading Straight 2 of 5 Industrial bar
codes, you may want to adjust the redundancy count. Redundancy adjusts
the number of times a bar code is decoded before transmission, which may
reduce the number of errors. Note that the higher the redundancy count,
the longer it will take to decode the bar code. To adjust the redundancy,
scan the Straight 2 of 5 Industrial Redundancy bar code below, then
6 - 15
Download from Www.Somanuals.com. All Manuals Search And Download.
scan a redundancy count between 0 and 10 on the Programming Chart
Default = 0.
Straight 2 of 5 Industrial
Redundancy
Straight 2 of 5 Industrial Message Length
Scan the bar codes below to change the message length. Refer to
mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
6 - 16
Download from Www.Somanuals.com. All Manuals Search And Download.
Straight 2 of 5 IATA (two-bar start/stop)
Note: This symbology is also known as Airline Code 5.
<Default All Straight 2 of 5 IATA Settings>
Straight 2 of 5 IATA On/Off
On
* Off
Straight 2 of 5 IATA Redundancy
If you are encountering errors when reading Straight 2 of 5 IATA bar codes,
you may want to adjust the redundancy count. Redundancy adjusts the
number of times a bar code is decoded before transmission, which may
reduce the number of errors. Note that the higher the redundancy count,
the longer it will take to decode the bar code. To adjust the redundancy,
scan the Straight 2 of 5 IATA Redundancy bar code below, then scan a
Straight 2 of 5 IATA
Redundancy
6 - 17
Download from Www.Somanuals.com. All Manuals Search And Download.
Straight 2 of 5 IATA Message Length
Scan the bar codes below to change the message length. Refer to
mum and Maximum lengths = 1-80. Minimum Default = 13, Maximum
Default = 15.
Minimum Message Length
Maximum Message Length
Matrix 2 of 5
<Default All Matrix 2 of 5 Settings>
Matrix 2 of 5 On/Off
On
* Off
Matrix 2 of 5 Check Character
No Check Character indicates that the scanner reads and transmits bar
code data with or without a check character.
When Check Character is set to Validate, but Don’t Transmit, the unit
only reads Matrix 2 of 5 bar codes printed with a check character, but will
not transmit the check character with the scanned data.
6 - 18
Download from Www.Somanuals.com. All Manuals Search And Download.
When Check Character is set to Validate and Transmit, the scanner only
reads Matrix 2 of 5 bar codes printed with a check character, and will trans-
mit this character at the end of the scanned data. Default = No Check
Character.
* No Check Character
Validate, but Don’t Transmit
Validate and Transmit
Matrix 2 of 5 Redundancy
If you are encountering errors when reading Matrix 2 of 5 bar codes, you
may want to adjust the redundancy count. Redundancy adjusts the num-
ber of times a bar code is decoded before transmission, which may reduce
the number of errors. Note that the higher the redundancy count, the lon-
ger it will take to decode the bar code. To adjust the redundancy, scan the
Matrix 2 of 5 Redundancy bar code below, then scan a redundancy count
Matrix 2 of 5 Redundancy
Matrix 2 of 5 Message Length
Scan the bar codes below to change the message length. Refer to
mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
6 - 19
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 11
<Default All Code 11 Settings>
Code 11 On/Off
On
* Off
Check Digits Required
These options set whether 1 or 2 check digits are required with Code 11
bar codes. Auto Select Check Digits determines the number of check
digits based on the length of the bar code. If the bar code is 10 digits or
more, 2 check digits are required. If it is 9 digits or less, 1 check digit is
required. The check digit data is only transmitted if you program that fea-
Required.
One Check Digit Required
* Two Check Digits Required
Auto Select Check Digits
Required
6 - 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Check Digit Validation
When Check Character is set to Validate and Transmit, the scanner will
only read Code 11 bar codes printed with the specified type check charac-
ter(s), and will transmit the character(s) at the end of the scanned data.
Validate and Transmit One
Check Digit
Validate and Transmit Two
Check Digits
Validate and Transmit Auto
Select Check Digits
Code 11 Redundancy
If you are encountering errors when reading Code 11 bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the Code
11 Redundancy bar code below, then scan a redundancy count between 0
Code 11 Redundancy
6 - 21
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 128
<Default All Code 128 Settings>
Code 128 On/Off
* On
Off
128 Group Separator Output
If you wish to transmit the group separator characters “GS” (0x1D hex) with
your Code 128 bar code output, scan the On bar code. When Off is
scanned, the group separator is not output. Default =Off.
On
* Off
Code 128 Redundancy
If you are encountering errors when reading Code 128 bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the Code
6 - 23
Download from Www.Somanuals.com. All Manuals Search And Download.
128 Redundancy bar code below, then scan a redundancy count between
Code 128 Redundancy
Code 128 Message Length
Scan the bar codes below to change the message length. Refer to
mum and Maximum lengths = 1-80. Minimum Default = 1, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
ISBT 128
ISBT is a variation of Code 128 that supports concatenation of neighboring
symbols on a blood product label. Use the bar codes below to turn ISBT 128
concatenation on or off. Default =Off.
On
* Off
6 - 24
Download from Www.Somanuals.com. All Manuals Search And Download.
Concatenation Timeout
When searching for bar codes during concatenation, you may wish to set a
delay used to find the next bar code. Set the length (in milliseconds) for this
delay by scanning the bar code below, then setting the timeout (from 1-
Concatenation Timeout
ISBT 128 Predefined Concatenation Sequences
Note: You must enable Code 128 and ISBT 128 to use this feature.
The following bar codes are used to select the pre-defined ISBT 128 Con-
catenation Sequence you wish to use. Once you have selected the concat-
enation sequence, use ISBT 128 Predefined Concatenation Sequences
and ABO/RhD Blood Groups (002).
* Donation ID Number (001)
and ABO/RhD Blood Groups (002)
Donation ID Number (001) and
Donor ID Number (019)
Donation ID Number (001) and
Confidential Unit Exclusion
Status
Product Code (003) and
Expiration Date (Form 1)
Product Code (003) and
Expiration Date (Form 2)
Product Code (003) and
Expiration Date (Form 3)
Product Code (003) and
Expiration Date (Form 4)
6 - 25
Download from Www.Somanuals.com. All Manuals Search And Download.
ISBT 128 Predefined Concatenation Sequences On/
Off
The following selections allow you to enable or require the Predefined ISBT
128 Concatenation Sequences.
If you scan Off, the predefined concatenation sequences are disabled.
If you scan the Allow Predefined Sequence code, then the scanner will
output only the data combination specified in the predefined concatenation
sequence you selected.
If you scan the Require Predefined Sequence code, the data combination
specified in the predefined concatenation sequence you selected is
required to transmit the data. No data is output unless the sequence is
read.
Default = Off.
* Off
Allow Predefined Sequence
Require Predefined Sequence
ISBT 128 User-Defined Concatenation Sequences
Note: You must enable Code 128 and ISBT 128 to use this feature.
The following bar codes are used to create a custom ISBT 128 Concatena-
tion Sequence. Select the identifiers you want to transmit in the 1st and
2nd positions, both left and right. Refer to the ISBT 128 Standard Techni-
cal Specification for the list of data identifiers.
Chart inside the back cover of this manual.
Example: You want to create a concatenation sequence that has the
Donation Identification Number (001) as the left identifier, and Product
Code (003) as the right identifier.
The ISBT Index of Data Structures shows that for the Donation Identifica-
tion Number, the first character is “=” and the second character can be from
A-N; P-Z; 1-9. For this example, use “G.” The Product Code first character
is “=” and the second character is “<.”
6 - 26
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 1. Scan the 1st Left Identifier bar code, below.
Step 4. Scan the 2nd Left Identifier bar code, below.
Step 7. Scan the 1st Right Identifier bar code, below.
Step 10. Scan the 2nd Right Identifier bar code, below.
Once you have programmed the concatenation sequence, use ISBT 128
0.
1st Left Identifier
2nd Left Identifier
1st Right Identifier
2nd Right Identifier
ISBT 128 User-Defined Concatenation Sequences
On/Off
The following selections allow you to enable or require the User-Defined
ISBT 128 Concatenation Sequences.
If you scan Off, the User-Defined concatenation sequences are disabled.
If you scan the Allow User-Defined Sequence code, then the scanner will
output only the data combination specified in the User-Defined concatena-
tion sequence you created.
6 - 27
Download from Www.Somanuals.com. All Manuals Search And Download.
If you scan the Require User-Defined Sequence code, the data combina-
tion specified in the User-Defined concatenation sequence is required to
transmit the data. No data is output unless the sequence is read.
Default = Off.
* Off
Allow User-Defined Sequence
Require User-Defined Sequence
Content Verification
When the On bar code is scanned, the check character values are output
along with the bar code data, thus allowing you to verify that the check
character is in agreement with that calculated for the data stream. Default
= Off.
On
* Off
Transmit Identifiers
You may disable the transmission of the ISBT Code 128 data identifiers by
scanning Off. When this selection is Off, the first 2 data (ID) characters
are removed from the data stream unless the ISBT code contains the
Donation Identification Number identifiers. If the code contains the Dona-
6 - 28
Download from Www.Somanuals.com. All Manuals Search And Download.
tion Identification Number identifiers, only the first ID character is removed
from the Donation Identification Number. The second character is transmit-
ted as normal data. Default = On.
* On
Off
Flag Digit Conversion
Type 3 flag digits are a part of the Donation Identification Number in an
ISBT 128 bar code. If you select On, the flag data is converted into a single
MOD (37, 2) character and transmitted with the bar code data. Scan Off if
you do not want the flag digits transmitted. Default = Off.
On
* Off
6 - 29
Download from Www.Somanuals.com. All Manuals Search And Download.
GS1-128
<Default All GS1-128 Settings>
GS1-128 On/Off
* On
Off
GS1-128 Application Identifier Parsing
This allows a single GS1-128 bar code to be broken into multiple transmis-
sions based on the presence of application identifiers (AI) embedded in the
bar code. Scan Transmit Without Identifiers if you want the bar code
broken into packets and stripped of the AI. If you want the AI included,
scan Transmit With Identifiers. Default = Off.
* Off
Transmit Without Identifiers
Transmit With Identifiers
GS1-128 Redundancy
If you are encountering errors when reading GS1-128 bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the GS1-
6 - 30
Download from Www.Somanuals.com. All Manuals Search And Download.
128 Redundancy bar code below, then scan a redundancy count between
GS1-128 Redundancy
GS1-128 Message Length
Scan the bar codes below to change the message length. Refer to
mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
6 - 31
Download from Www.Somanuals.com. All Manuals Search And Download.
Telepen
<Default All Telepen Settings>
Telepen On/Off
On
* Off
Telepen Output
Using AIM Telepen Output, the scanner reads symbols with start/stop pat-
tern 1 and decodes them as standard full ASCII (start/stop pattern 1).
When Original Telepen Output is selected, the scanner reads symbols with
start/stop pattern 1 and decodes them as compressed numeric with
optional full ASCII (start/stop pattern 2). Default = AIM Telepen Output.
* AIM Telepen Output
Original Telepen Output
Telepen Redundancy
If you are encountering errors when reading Telepen bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the
6 - 32
Download from Www.Somanuals.com. All Manuals Search And Download.
Telepen Redundancy bar code below, then scan a redundancy count
Telepen Redundancy
Telepen Message Length
Scan the bar codes below to change the message length. Refer to
mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
6 - 33
Download from Www.Somanuals.com. All Manuals Search And Download.
UPC-A
<Default All UPC-A Settings>
UPC-A On/Off
* On
Off
UPC-A Number System and Check Digit
UPC-A sample showing the number system and check digit:
Number
System
Check
Digit
UPC-A Number System
The numeric system digit of a U.P.C. symbol is normally transmitted at
the beginning of the scanned data, but the can be programmed so it
will not transmit it. Default = On.
* On
Off
6 - 34
Download from Www.Somanuals.com. All Manuals Search And Download.
UPC-A Check Digit
This selection allows you to specify whether the check digit should be
transmitted at the end of the scanned data or not. Default = On.
* On
Off
UPC-A Addenda
This selection adds 2 or 5 digits to the end of all scanned UPC-A data.
Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
UPC-A Addenda Required
When Required is scanned, the scanner will only read UPC-A bar codes
that have addenda. You must then turn on a 2 or 5 digit addenda listed on
Required
* Not Required
6 - 35
Download from Www.Somanuals.com. All Manuals Search And Download.
Addenda Timeout
You can set a time during which the scanner looks for an addenda. If an
addenda is not found within this time period, the data can be either trans-
mitted or discarded, based on the setting you are using for UPC-A
this timeout by scanning the bar code below, then setting the timeout (from
Note: The Addenda Timeout setting is applied to all addenda and coupon
code searches.
Addenda Timeout
UPC-A Addenda Separator
When this feature is on, there is a space between the data from the bar
code and the data from the addenda. When turned off, there is no space.
Default = Off.
On
* Off
UPC-A Redundancy
If you are encountering errors when reading UPC-A bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the UPC-
A Redundancy bar code below, then scan a redundancy count between 0
UPC-A Redundancy
6 - 36
Download from Www.Somanuals.com. All Manuals Search And Download.
UPC-A/EAN-13 with Extended Coupon Code
Use the following codes to enable or disable UPC-A and EAN-13 with Extended
Coupon Code. When left on the default setting (Off), the scanner treats Cou-
pon Codes and Extended Coupon Codes as single bar codes.
If you scan the Allow Concatenation code, when the scanner sees the coupon
code and the extended coupon code in a single scan, it transmits both as sepa-
rate symbologies. Otherwise, it transmits the first coupon code it reads.
If you scan the Require Concatenation code, the scanner must see and read
the coupon code and extended coupon code in a single read to transmit the
data. No data is output unless both codes are read.
Default = Off.
* Off
Allow Concatenation
Require Concatenation
UPC-A Number System 4 Addenda Required
This setting programs the scanner to require a coupon code only on UPC-A
bar codes that begin with a “4.” The following settings can be programmed:
Require Coupon Code: All UPC-A bar codes that begin with a “4” must
have a coupon code. The UPC-A bar code with the coupon code is then
transmitted as a single, concatenated bar code. If a coupon code is not
carded.
Don’t Require Coupon Code: If you have selected Require Coupon
Code, and you want to disable this feature, scan Don’t Require Coupon
Code. UPC-A bar codes are transmitted, depending on the setting you are
6 - 37
Download from Www.Somanuals.com. All Manuals Search And Download.
Default = Don’t Require Coupon Code.
* Don’t Require Coupon Code
Require Coupon Code
UPC-A Number System 5 Addenda Required
This setting programs the scanner to require any combination of a coupon
code, a 2 digit addenda, or a 5 digit addenda on UPC-A bar codes that
begin with a “5.” The following settings can be programmed:
Require Coupon Code/Addenda: All UPC-A bar codes that begin with a
“5” must have a coupon code, a 2 digit addenda, a 5 digit addenda, or a
combination of these addenda. The UPC-A bar code with the coupon code
and/or addenda is then transmitted as a single, concatenated bar code. If
a coupon code and/or required addenda is not found within the Addenda
Timeout period, the UPC-A bar code is discarded.
Don’t Require Coupon Code/Addenda: If you have selected Require
Coupon Code/Addenda, and you want to disable this feature, scan Don’t
Require Coupon Code/Addenda. UPC-A bar codes are transmitted,
depending on the setting you are using for UPC-A/EAN-13 with Extended
6 - 38
Download from Www.Somanuals.com. All Manuals Search And Download.
Default = Don’t Require Coupon Code/Addenda.
* Don’t Require Coupon Code/
Addenda
Require 2 Digit Addenda
Require 5 Digit Addenda
Require 2 or 5 Digit Addenda
Require Coupon Code
Require Coupon Code or 2 Digit
Addenda
Require Coupon Code or 5 Digit
Addenda
Require Coupon Code, 2 Digit
Addenda, or 5 Digit Addenda
Addenda Timeout
You can set a time during which the scanner looks for a coupon code. If a
coupon code is not found within this time period, the data can be either
transmitted or discarded, based on the setting you are using for UPC-A/
6 - 39
Download from Www.Somanuals.com. All Manuals Search And Download.
scanning the bar code below, then setting the timeout (from 0-65535 milli-
Note: The Addenda Timeout setting is applied to all addenda and coupon
code searches.
Addenda Timeout
UPC-E0
<Default All UPC-E0 Settings>
UPC-E0 On/Off
Most U.P.C. bar codes lead with the 0 number system. To read these
codes, use the UPC-E0 On selection. If you need to read codes that lead
* UPC-E0 On
UPC-E0 Off
UPC-E0 Expand
UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format.
Default = Off.
On
* Off
6 - 40
Download from Www.Somanuals.com. All Manuals Search And Download.
UPC-E0 Number System
The numeric system digit of a UPC-A symbol is normally transmitted at the
beginning of scanned data. When using UPC-E Expand, the unit can be
programmed so it will not transmit it. Default = On.
* On
Off
UPC-E0 Number System and Check Digit
UPC-E0 sample showing the number system and check digit:
Number
System
Check
Digit
UPC-E0 Check Digit
Check Digit specifies whether the check digit should be transmitted at
the end of the scanned data or not. Default = Off.
On
* Off
6 - 41
Download from Www.Somanuals.com. All Manuals Search And Download.
UPC-E0 Leading Zero
This feature allows the transmission of a leading zero (0) at the beginning
of scanned data. To prevent transmission, scan Off. Default = Off.
On
* Off
UPC-E0 Addenda
This selection adds 2 or 5 digits to the end of all scanned UPC-E data.
Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
UPC-E0 Addenda Required
When Required is scanned, the scanner will only read UPC-E bar codes
that have addenda. Default = Not Required.
Required
* Not Required
6 - 42
Download from Www.Somanuals.com. All Manuals Search And Download.
Addenda Timeout
You can set a time during which the scanner looks for an addenda. If an
addenda is not found within this time period, the data can be either trans-
mitted or discarded, based on the setting you are using for UPC-E0
timeout by scanning the bar code below, then setting the timeout (from 0-
Note: The Addenda Timeout setting is applied to all addenda and coupon
code searches.
Addenda Timeout
UPC-E0 Addenda Separator
When this feature is On, there is a space between the data from the bar
code and the data from the addenda. When turned Off, there is no space.
Default = Off.
On
* Off
UPC-E0 Redundancy
If you are encountering errors when reading UPC-E0 bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the UPC-
E0 Redundancy bar code below, then scan a redundancy count between 0
UPC-E0 Redundancy
6 - 43
Download from Www.Somanuals.com. All Manuals Search And Download.
EAN/JAN-13
<Default All EAN/JAN Settings>
EAN/JAN-13 On/Off
* On
Off
EAN/JAN-13 Check Digit
This selection allows you to specify whether the check digit should be
transmitted at the end of the scanned data or not. Default = On.
* On
Off
6 - 44
Download from Www.Somanuals.com. All Manuals Search And Download.
EAN/JAN-13 Addenda
This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13
data. Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
EAN/JAN-13 Addenda Required
When Required is scanned, the scanner will only read EAN/JAN-13 bar
codes that have addenda. Default = Not Required.
Required
* Not Required
EAN-13 Beginning with 2 Addenda Required
This setting programs the scanner to require a 2 digit addenda only on
EAN-13 bar codes that begin with a “2.” The following settings can be pro-
grammed:
Require 2 Digit Addenda: All EAN-13 bar codes that begin with a “2”
must have a 2 digit addendum. The EAN-13 bar code with the 2 digit
addendum is then transmitted as a single, concatenated bar code. If a 2
13 bar code is discarded.
(page 6-46), that setting will take precedence over this one.
6 - 45
Download from Www.Somanuals.com. All Manuals Search And Download.
Don’t Require 2 Digit Addenda: If you have selected Require 2 Digit
Addenda, and you want to disable this feature, scan Don’t Require 2 Digit
Addenda. EAN-13 bar codes are transmitted, depending on the setting
Default = Don’t Require 2 Digit Addenda.
* Don’t Require 2 Digit
Addenda
Require 2 Digit Addenda
EAN-13 Beginning with 290 Addenda Required
This setting programs the scanner to require a 5 digit addenda only on
EAN-13 bar codes that begin with “290.” The following settings can be pro-
grammed:
Require 5 Digit Addenda: All EAN-13 bar codes that begin with “290”
must have a 5 digit addendum. The EAN-13 bar code with the 5 digit
addendum is then transmitted as a single, concatenated bar code. If a 5
13 bar code is discarded.
6-45), this setting will take precedence.
Don’t Require 5 Digit Addenda: If you have selected Require 5 Digit
Addenda, and you want to disable this feature, scan Don’t Require 5 Digit
Addenda. EAN-13 bar codes are transmitted, depending on the setting
Default = Don’t Require 5 Digit Addenda.
* Don’t Require 5 Digit
Addenda
Require 5 Digit Addenda
EAN-13 Beginning with 378/379
Addenda Required
This setting programs the scanner to require any combination of a 2 digit
addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “378”
or “379.” The following settings can be programmed:
6 - 46
Download from Www.Somanuals.com. All Manuals Search And Download.
Require Addenda: All EAN-13 bar codes that begin with a “378” or “379”
must have a 2 digit addenda, a 5 digit addenda, or a combination of these
addenda. The EAN-13 bar code with the addenda is then transmitted as a
single, concatenated bar code. If the required addenda is not found within
Don’t Require Addenda: If you have selected Require Addenda, and
you want to disable this feature, scan Don’t Require Addenda. EAN-13
bar codes are transmitted, depending on the setting you are using for EAN/
Default = Don’t Require Addenda.
* Don’t Require Addenda
Require 2 Digit Addenda
Require 5 Digit Addenda
Require 2 or 5 Digit Addenda
EAN-13 Beginning with 414/419
Addenda Required
This setting programs the scanner to require any combination of a 2 digit
addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “414”
or “419.” The following settings can be programmed:
Require Addenda: All EAN-13 bar codes that begin with a “414” or “419”
must have a 2 digit addenda, a 5 digit addenda, or a combination of these
addenda. The EAN-13 bar code with the addenda is then transmitted as a
single, concatenated bar code. If the required addenda is not found within
Don’t Require Addenda: If you have selected Require Addenda, and
you want to disable this feature, scan Don’t Require Addenda. EAN-13
bar codes are transmitted, depending on the setting you are using for EAN/
6 - 47
Download from Www.Somanuals.com. All Manuals Search And Download.
Default = Don’t Require Addenda.
* Don’t Require Addenda
Require 2 Digit Addenda
Require 5 Digit Addenda
Require 2 or 5 Digit Addenda
EAN-13 Beginning with 434/439
Addenda Required
This setting programs the scanner to require any combination of a 2 digit
addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “434”
or “439.” The following settings can be programmed:
Require Addenda: All EAN-13 bar codes that begin with a “434” or “439”
must have a 2 digit addenda, a 5 digit addenda, or a combination of these
addenda. The EAN-13 bar code with the addenda is then transmitted as a
single, concatenated bar code. If the required addenda is not found within
Don’t Require Addenda: If you have selected Require Addenda, and
you want to disable this feature, scan Don’t Require Addenda. EAN-13
bar codes are transmitted, depending on the setting you are using for EAN/
6 - 48
Download from Www.Somanuals.com. All Manuals Search And Download.
Default = Don’t Require Addenda.
* Don’t Require Addenda
Require 2 Digit Addenda
Require 5 Digit Addenda
Require 2 or 5 Digit Addenda
EAN-13 Beginning with 977 Addenda Required
This setting programs the scanner to require a 2 digit addenda only on
EAN-13 bar codes that begin with “977.” The following settings can be pro-
grammed:
Require 2 Digit Addenda: All EAN-13 bar codes that begin with “977”
must have a 2 digit addendum. The EAN-13 bar code with the 2 digit
addendum is then transmitted as a single, concatenated bar code. If a 2
13 bar code is discarded.
Don’t Require 2 Digit Addenda: If you have selected Require 2 Digit
Addenda, and you want to disable this feature, scan Don’t Require 2 Digit
Addenda. EAN-13 bar codes are transmitted, depending on the setting
Default = Don’t Require 2 Digit Addenda.
* Don’t Require 2 Digit
Addenda
Require 2 Digit Addenda
EAN-13 Beginning with 978 Addenda Required
These settings program the scanner to require a 5 digit addenda only on
EAN-13 bar codes that begin with “978.” The following settings can be pro-
grammed:
6 - 49
Download from Www.Somanuals.com. All Manuals Search And Download.
Require 5 Digit Addenda: All EAN-13 bar codes that begin with “978”
must have a 5 digit addendum. The EAN-13 bar code with the 5 digit
addendum is then transmitted as a single, concatenated bar code. If a 5
13 bar code is discarded.
Don’t Require 5 Digit Addenda: If you have selected Require 5 Digit
Addenda, and you want to disable this feature, scan Don’t Require 5 Digit
Addenda. EAN-13 bar codes are transmitted, depending on the setting
Default = Don’t Require 5 Digit Addenda.
* Don’t Require 5 Digit
Addenda
Require 5 Digit Addenda
EAN-13 Beginning with 979 Addenda Required
These settings program the scanner to require a 5 digit addenda only on
EAN-13 bar codes that begin with “979.” The following settings can be pro-
grammed:
Require 5 Digit Addenda: All EAN-13 bar codes that begin with “979”
must have a 5 digit addendum. The EAN-13 bar code with the 5 digit
addendum is then transmitted as a single, concatenated bar code. If a 5
13 bar code is discarded.
Don’t Require 5 Digit Addenda: If you have selected Require 5 Digit
Addenda, and you want to disable this feature, scan Don’t Require 5 Digit
Addenda. EAN-13 bar codes are transmitted, depending on the setting
Default = Don’t Require 5 Digit Addenda.
* Don’t Require 5 Digit
Addenda
Require 5 Digit Addenda
6 - 50
Download from Www.Somanuals.com. All Manuals Search And Download.
Addenda Timeout
You can set a time during which the scanner looks for an addenda. If an
addenda is not found within this time period, the data can be either trans-
mitted or discarded, based on the setting you are using for EAN/JAN-13
scanning the bar code below, then setting the timeout (from 0-65535 milli-
Note: The Addenda Timeout setting is applied to all addenda and coupon
code searches.
Addenda Timeout
EAN/JAN-13 Addenda Separator
When this feature is On, there is a space between the data from the bar
code and the data from the addenda. When turned Off, there is no space.
Default = Off.
On
* Off
Note: If you want to enable or disable EAN13 with Extended Coupon Code,
EAN/JAN-13 Redundancy
If you are encountering errors when reading EAN/JAN-13 bar codes, you
may want to adjust the redundancy count. Redundancy adjusts the num-
ber of times a bar code is decoded before transmission, which may reduce
the number of errors. Note that the higher the redundancy count, the lon-
ger it will take to decode the bar code. To adjust the redundancy, scan the
EAN/JAN-13 Redundancy bar code below, then scan a redundancy count
EAN/JAN-13 Redundancy
6 - 51
Download from Www.Somanuals.com. All Manuals Search And Download.
ISBN Translate
ISBNs are printed on books using the EAN-13 bar code symbology. To
translate EAN-13 Bookland symbols into their equivalent ISBN number for-
mat, scan the On bar code below. Default = Off.
On
* Off
Convert ISBN to 13-Digit
When translating EAN-13 codes to the ISBN format, you can convert
the bar code to a 13 digit format by scanning the Convert to 13-Digit
On bar code below. Default = Convert to 13-Digit Off.
Convert to 13-Digit On
*Convert to 13-Digit Off
ISBN Reformat
In normal use, the first two or three digits of an EAN-13 bar code iden-
tify the country of origin. The country prefixes are 978 and 979. To
reformat ISBN codes so the country prefix is dropped out, scan the
Reformat On bar code below. Default = Reformat Off.
Reformat On
*Reformat Off
6 - 52
Download from Www.Somanuals.com. All Manuals Search And Download.
ISSN Translate
When On is scanned, EAN-13 977 Bookland symbols are translated into
their equivalent 8-digit ISSN number format. For example, 9770123456787
will be transmitted as 01234560. Default = Off.
On
* Off
ISSN Reformat
When Reformat On is scanned, EAN-13 977 Bookland symbols are
translated into their equivalent 8-digit ISSN number format, with
hyphens added to the output. For example, 9770123456787 will be
before scanning Reformat On.) Default = Reformat Off.
Reformat On
* Reformat Off
6 - 53
Download from Www.Somanuals.com. All Manuals Search And Download.
EAN/JAN-8
<Default All EAN/JAN-8 Settings>
EAN/JAN-8 On/Off
* On
Off
EAN/JAN-8 Check Digit
This selection allows you to specify whether the check digit should be
transmitted at the end of the scanned data or not. Default = On.
* On
Off
6 - 54
Download from Www.Somanuals.com. All Manuals Search And Download.
EAN/JAN-8 Addenda
This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data.
Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
EAN/JAN-8 Addenda Required
When Required is scanned, the scanner will only read EAN/JAN-8 bar
codes that have addenda. Default = Not Required.
Required
* Not Required
Addenda Timeout
You can set a time during which the scanner looks for an addenda. If an
addenda is not found within this time period, the data can be either trans-
mitted or discarded, based on the setting you are using for EAN/JAN-8
6 - 55
Download from Www.Somanuals.com. All Manuals Search And Download.
scanning the bar code below, then setting the timeout (from 0-65535 milli-
Note: The Addenda Timeout setting is applied to all addenda and coupon
code searches.
Addenda Timeout
EAN/JAN-8 Addenda Separator
When this feature is On, there is a space between the data from the bar
code and the data from the addenda. When turned Off, there is no space.
Default = Off.
On
* Off
EAN/JAN-8 Redundancy
If you are encountering errors when reading EAN/JAN-8 bar codes, you
may want to adjust the redundancy count. Redundancy adjusts the num-
ber of times a bar code is decoded before transmission, which may reduce
the number of errors. Note that the higher the redundancy count, the lon-
ger it will take to decode the ba code. To adjust the redundancy, scan the
EAN/JAN-8 Redundancy bar code below, then scan a redundancy count
EAN/JAN-8 Redundancy
6 - 56
Download from Www.Somanuals.com. All Manuals Search And Download.
MSI
<Default All MSI Settings>
MSI On/Off
On
* Off
MSI Check Character
Different types of check characters are used with MSI bar codes. You can
program the scanner to read MSI bar codes with Type 10 check charac-
ters. Default = Validate Type 10, but Don’t Transmit.
When Check Character is set to Validate Type 10/11 and Transmit, the
scanner will only read MSI bar codes printed with the specified type check
character(s), and will transmit the character(s) at the end of the scanned
data.
6 - 57
Download from Www.Somanuals.com. All Manuals Search And Download.
When Check Character is set to Validate Type 10/11, but Don’t Transmit,
the unit will only read MSI bar codes printed with the specified type check
character(s), but will not transmit the check character(s) with the scanned
data.
* Validate Type 10, but Don’t
Transmit
Validate Type 10 and Transmit
Validate 2 Type 10 Characters,
but Don’t Transmit
Validate 2 Type 10 Characters
and Transmit
Validate Type 10 then Type 11
Character, but Don’t Transmit
Validate Type 10 then
Type 11 Character and Transmit
Disable MSI Check Characters
MSI Redundancy
If you are encountering errors when reading MSI bar codes, you may want
to adjust the redundancy count. Redundancy adjusts the number of times
a bar code is decoded before transmission, which may reduce the number
of errors. Note that the higher the redundancy count, the longer it will take
to decode the bar code. To adjust the redundancy, scan the MSI Redun-
dancy bar code below, then scan a redundancy count between 0 and 10
MSI Redundancy
6 - 58
Download from Www.Somanuals.com. All Manuals Search And Download.
MSI Message Length
Scan the bar codes below to change the message length. Refer to
mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
Plessey Code
< Default All Plessey Code Settings >
Plessey Code On/Off
On
* Off
Plessey Check Character
No Check Character indicates that the scanner reads and transmits bar
code data with or without a check character.
When Check Character is set to Validate, but Don’t Transmit, the unit
only reads Plessey bar codes printed with a check character, but will not
transmit the check character with the scanned data.
6 - 59
Download from Www.Somanuals.com. All Manuals Search And Download.
When Check Character is set to Validate and Transmit, the scanner only
reads Plessey bar codes printed with a check character, and will transmit
this character at the end of the scanned data. Default = No Check Charac-
ter.
* No Check Character
Validate, but Don’t Transmit
Validate and Transmit
Plessey Redundancy
If you are encountering errors when reading Plessey bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the
Plessey Redundancy bar code below, then scan a redundancy count
Plessey Redundancy
Plessey Message Length
Scan the bar codes below to change the message length. Refer to
mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
6 - 60
Download from Www.Somanuals.com. All Manuals Search And Download.
GS1 DataBar Omnidirectional
< Default All GS1 DataBar Omnidirectional Settings >
GS1 DataBar Omnidirectional On/Off
* On
Off
GS1 DataBar Omnidirectional Redundancy
If you are encountering errors when reading GS1 DataBar Omnidirectional
bar codes, you may want to adjust the redundancy count. Redundancy
adjusts the number of times a bar code is decoded before transmission,
which may reduce the number of errors. Note that the higher the redun-
dancy count, the longer it will take to decode the bar code. To adjust the
redundancy, scan the GS1 DataBar Omnidirectional Redundancy bar
code below, then scan a redundancy count between 0 and 10 on the
GS1 DataBar Omnidirectional
Redundancy
6 - 61
Download from Www.Somanuals.com. All Manuals Search And Download.
GS1 DataBar Limited
< Default All GS1 DataBar Limited Settings >
GS1 DataBar Limited On/Off
* On
Off
GS1 DataBar Limited Redundancy
If you are encountering errors when reading GS1 DataBar Limited bar
codes, you may want to adjust the redundancy count. Redundancy adjusts
the number of times a bar code is decoded before transmission, which may
reduce the number of errors. Note that the higher the redundancy count,
the longer it will take to decode the bar code. To adjust the redundancy,
scan the GS1 DataBar Limited Redundancy bar code below, then scan a
GS1 DataBar Limited
Redundancy
6 - 62
Download from Www.Somanuals.com. All Manuals Search And Download.
GS1 DataBar Expanded
< Default All GS1 DataBar Expanded Settings >
GS1 DataBar Expanded On/Off
* On
Off
GS1 DataBar Expanded Redundancy
If you are encountering errors when reading GS1 DataBar Expanded bar
codes, you may want to adjust the redundancy count. Redundancy adjusts
the number of times a bar code is decoded before transmission, which may
reduce the number of errors. Note that the higher the redundancy count,
the longer it will take to decode the bar code. To adjust the redundancy,
scan the GS1 DataBar Expanded Redundancy bar code below, then
scan a redundancy count between 0 and 10 on the Programming Chart
Default = 0.
GS1 DataBar Expanded
Redundancy
6 - 63
Download from Www.Somanuals.com. All Manuals Search And Download.
GS1 DataBar Expanded Message Length
Scan the bar codes below to change the message length. Refer to
mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.
Minimum Message Length
Maximum Message Length
Trioptic Code
Trioptic Code is used for labeling magnetic storage media.
On
* Off
GS1 Emulation
The scanner can automatically format the output from any GS1 data carrier to
emulate what would be encoded in an equivalent GS1-128 or GS1 DataBar
symbol. GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8,
ITF-14, GS1-128, and GS1-128 DataBar and GS1 Composites. (Any applica-
tion that accepts GS1 data can be simplified since it only needs to recognize
one data carrier type.)
If GS1-128 Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8,
EAN13) are expanded out to 16 digits. If the AIM ID is enabled, the value will
If GS1 DataBar Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8,
EAN13) are expanded out to 16 digits. If the AIM ID is enabled, the value will
If GS1 Code Expansion Off is scanned, retail code expansion is disabled, and
the AIM ID is enabled, the value will be the GS1-128 AIM ID, ]C1 (see
6 - 64
Download from Www.Somanuals.com. All Manuals Search And Download.
If EAN8 to EAN13 Conversion is scanned, all EAN8 bar codes are converted
to EAN13 format.
Default = GS1 Emulation Off.
GS1-128 Emulation
GS1 DataBar Emulation
GS1 Code Expansion Off
EAN8 to EAN13 Conversion
* GS1 Emulation Off
Postal Codes
The following lists linear postal codes. Any combination of linear postal code
selections can be active at a time.
China Post (Hong Kong 2 of 5)
<Default All China Post (Hong Kong 2 of 5) Settings>
6 - 65
Download from Www.Somanuals.com. All Manuals Search And Download.
China Post (Hong Kong 2 of 5) On/Off
On
* Off
China Post (Hong Kong 2 of 5) Redundancy
If you are encountering errors when reading China Post (Hong Kong 2
of 5) bar codes, you may want to adjust the redundancy count.
Redundancy adjusts the number of times a bar code is decoded
before transmission, which may reduce the number of errors. Note
that the higher the redundancy count, the longer it will take to decode
the bar code. To adjust the redundancy, scan the China Post (Hong
Kong 2 of 5) Redundancy bar code below, then scan a redundancy
China Post (Hong Kong 2 of 5)
Redundancy
China Post (Hong Kong 2 of 5) Message Length
Scan the bar codes below to change the message length. Refer to
Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maxi-
mum Default = 80.
Minimum Message Length
Maximum Message Length
6 - 66
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Interface Keys
Keyboard Function Relationships
The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII
“CTRL”+ relationships apply to all terminals that can be used with the scanner.
Function Code
HEX/ASCII Value
Full ASCII “CTRL” +
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
@
A
B
C
D
E
F
G
H
I
HT
LF
J
VT
K
L
FF
CR
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
[
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
SUB
ESC
FS
\
GS
]
RS
^
US
_
7 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to
US only. The following chart indicates the equivalents of these five characters
for different countries.
Note: Not all countries may be supported by your device.
Country
Codes
United States
Belgium
[
\
]
6
6
6
6
6
6
6
6
6
6
6
-
-
-
=
-
-
-
-
-
-
-
[
<
<
8
Ã
\
]
Scandinavia
France
8
^
9
$
+
+
. .
]
Germany
Italy
Switzerland
United Kingdom
Denmark
Norway
<
¢
\
[
8
8
[
9
9
]
\
Spain
\
Supported Interface Keys
IBM AT/XT and
PS/2
Compatibles,
WYSE PC/AT
Supported Keys
Apple Mac/iMac
Supported Keys
ASCII
HEX
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HT
LF
VT
FF
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
Reserved
Enter (KP)
Cap Lock
ALT make
ALT break
CTRL make
CTRL break
CR/Enter
Reserved
Tab
Reserved
Enter/Numpad Enter
CAPS
ALT make
ALT break
CNTRL make
CNTRL break
RETURN
APPLE make
TAB
Reserved
Tab
Delete
APPLE break
TAB
Del
7 - 2
Download from Www.Somanuals.com. All Manuals Search And Download.
IBM AT/XT and
PS/2
Compatibles,
WYSE PC/AT
Supported Keys
Apple Mac/iMac
Supported Keys
ASCII
HEX
CR
SO
SI
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
7F
CR/Enter
Insert
Escape
F11
Home
Print
Back Space
Back Tab
F12
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
RETURN
Ins Help
ESC
F11
Home
Prnt Scrn
BACKSPACE
LSHIFT TAB
F12
F1
F2
F3
F4
F5
F6
F7
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
SUB
ESC
FS
GS
RS
F8
F9
US
DEL
F10
BACKSPACE
7 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
7 - 4
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Utilities
To Add a Test Code I.D. Prefix to All Symbologies
This selection allows you to turn on transmission of a Code I.D. before the
the single character code that identifies each symbology.) This action first
clears all current prefixes, then programs a Code I.D. prefix for all symbologies.
This is a temporary setting that will be removed when the unit is power cycled.
Add Code I.D. Prefix to
All Symbologies (Temporary)
Show Software Revision
Scan the bar code below to output the current software revision, unit serial num-
ber, and other product information for both the scanner and base.
Show Revision
Show Data Format
Scan the bar code below to show current data format settings.
DFMBK3?.
Data Format Settings
8 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Test Menu
When you scan the Test Menu On code, then scan a programming code in this
manual, the scanner displays the content of a programming code. The pro-
gramming function will still occur, but in addition, the content of that program-
ming code is output to the terminal.
Note: This feature should not be used during normal scanner operation.
On
* Off
EZConfig-Scanning Introduction
EZConfig-Scanning provides a wide range of PC-based programming functions
that can be performed on a scanner connected to your PC's COM port. EZCon-
fig-Scanning allows you to download upgrades to the scanner's firmware,
change programmed parameters, and create and print programming bar codes.
Using EZConfig-Scanning, you can even save/open the programming parame-
ters for a scanner. This saved file can be e-mailed or, if required, you can cre-
ate a single bar code that contains all the customized programming parameters
and mail or fax that bar code to any location. Users in other locations can scan
the bar code to load in the customized programming.
To communicate with a scanner, EZConfig-Scanning requires that the PC have
at least one available serial communication port, or a serial port emulation using
a physical USB port. If you are using the serial port and RS232 cable, an exter-
nal power supply is required. When using a USB serial port emulation, only a
USB cable is required.
EZConfig-Scanning Operations
The EZConfig-Scanning software performs the following operations:
Scan Data
Scan Data allows you to scan bar codes and display the bar code data
in a window. Scan Data lets you send serial commands to the scanner
and receive scanner response that can be seen in the Scan Data win-
dow. The data displayed in the Scan Data window can either be saved
in a file or printed.
Configure
Configure displays the programming and configuration data of the
scanner. The scanner's programming and configuration data is
grouped into different categories. Each category is displayed as a tree
8 - 2
Download from Www.Somanuals.com. All Manuals Search And Download.
item under the “Configure” tree node in the application explorer. When
one of these tree nodes is clicked, the right-hand side is loaded with
the parameters' form belonging to that particular category. The Con-
figure tree option has all the programming and configuration parame-
ters specified for a scanner. You can set or modify these parameters
as required. You can later write the modified settings to the scanner,
or save them to a dcf file.
Installing EZConfig-Scanning from the Web
Note: EZConfig-Scanning requires .NET framework. If .NET is not
installed on your PC, you will be prompted to install it during the
EZConfig-Scanning installation.
2. Click on the Resources tab. Select Download.
3. Click on the dropdown for Select Product Number and select the
number of your product.
4. Under Tools and Utilities, click on the listing for EZConfig for
Scanning.
5. Follow the security directions as prompted on the screen and click on
Download.
6. When prompted, select Save, and save the file to your desktop.
7. Double click on the EZConfig-Scanning zip file.
8. Double click on the EZConfig-Scanning Setup.exe file. Select Extract
All.
9. Go to the EZConfig-Scanning folder that has been created on your
desktop and double click on the EZConfig-Scanning Setup.exe file.
10. Follow the screen prompts to install the EZConfig-Scanning program.
11. If you’ve selected the defaults during installation, you can click on the
shortcut on your desktop to start EZConfig for Scanning.
Once the software is installed, you may delete the zip file and the EZCon-
fig-Scanning folder from your desktop.
8 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Resetting the Factory Defaults
This selection erases all your settings and resets the scanner to the
original factory defaults.
!
If you aren’t sure what programming options are in your scanner, or you’ve
changed some options and want to restore the scanner to factory default set-
tings, first scan the Remove Custom Defaults bar code, then scan Activate
Defaults. This resets the scanner to the factory default settings.
Remove Custom Defaults
Activate Defaults
default settings for each of the commands (indicated by an asterisk (*) on the
programming pages).
8 - 4
Download from Www.Somanuals.com. All Manuals Search And Download.
9
Serial Programming Commands
The serial programming commands can be used in place of the programming
bar codes. Both the serial commands and the programming bar codes will pro-
gram the scanner. For complete descriptions and examples of each serial pro-
gramming command, refer to the corresponding programming bar code in this
manual.
commands can be sent via a PC COM port using terminal emulation software.
Conventions
The following conventions are used for menu and query command descriptions:
parameter A label representing the actual value you should send as part of a
command.
[option]
{Data}
bold
An optional part of a command.
Alternatives in a command.
Names of menus, menu commands, buttons, dialog boxes, and
windows that appear on the screen.
Menu Command Syntax
Menu commands have the following syntax (spaces have been used for clarity
only):
Prefix [:Name:] Tag SubTag {Data} [, SubTag {Data}] [; Tag SubTag {Data}] […]
Storage
Prefix Three ASCII characters: SYN M CR (ASCII 22,77,13).
:Name: To send information to the scanner (with the base connected to host),
use :Voyager: The default factory setting for a Voyager scanner is
Voyager scanner. If the name is not known, a wildcard (*) can be used
:*:.
Note: Since the base stores all work group settings and transfers to them to
scanner once they are linked, changes are typically done to the base and
not to the scanner.
Tag
A 3 character case-insensitive field that identifies the desired menu
command group. For example, all RS232 configuration settings are
identified with a Tag of 232.
SubTag A 3 character case-insensitive field that identifies the desired menu
command within the tag group. For example, the SubTag for the
RS232 baud rate is BAD.
Data
The new value for a menu setting, identified by the Tag and SubTag.
9 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Storage A single character that specifies the storage table to which the
command is applied. An exclamation point (!) performs the command’s
operation on the device’s volatile menu configuration table. A period (.)
performs the command’s operation on the device’s non-volatile menu
configuration table. Use the non-volatile table only for semi-permanent
changes you want saved through a power cycle.
Query Commands
Several special characters can be used to query the device about its settings.
^
?
*
What is the default value for the setting(s).
What is the device’s current value for the setting(s).
What is the range of possible values for the setting(s). (The device’s
response uses a dash (-) to indicate a continuous range of values. A
pipe (|) separates items in a list of non-continuous values.)
:Name: Field Usage (Optional)
This command returns the query information from the scanner.
Tag Field Usage
When a query is used in place of a Tag field, the query applies to the entire
set of commands available for the particular storage table indicated by the
Storage field of the command. In this case, the SubTag and Data fields
should not be used because they are ignored by the device.
SubTag Field Usage
When a query is used in place of a SubTag field, the query applies only to
the subset of commands available that match the Tag field. In this case,
the Data field should not be used because it is ignored by the device.
Data Field Usage
When a query is used in place of the Data field, the query applies only to
the specific command identified by the Tag and SubTag fields.
Concatenation of Multiple Commands
Multiple commands can be issued within one Prefix/Storage sequence.
Only the Tag, SubTag, and Data fields must be repeated for each com-
mand in the sequence. If additional commands are to be applied to the
same Tag, then the new command sequence is separated with a comma (,)
and only the SubTag and Data fields of the additional command are issued.
If the additional command requires a different Tag field, the command is
separated from previous commands by a semicolon (;).
9 - 2
Download from Www.Somanuals.com. All Manuals Search And Download.
Responses
The device responds to serial commands with one of three responses:
ACK Indicates a good command which has been processed.
ENQ Indicates an invalid Tag or SubTag command.
NAK Indicates the command was good, but the Data field entry was out of
the allowable range for this Tag and SubTag combination, e.g., an
entry for a minimum message length of 100 when the field will only
accept 2 characters.
When responding, the device echoes back the command sequence with
the status character inserted directly before each of the punctuation marks
(the period, exclamation point, comma, or semicolon) in the command.
Examples of Query Commands
In the following examples, a bracketed notation [ ] depicts a non-displayable
response.
Example: What is the range of possible values for Codabar Coding Enable?
Enter:
cbrena*.
Response: CBRENA0-1[ACK]
This response indicates that Codabar Coding Enable (CBRENA) has a range of
values from 0 to 1 (off and on).
Example: What is the default value for Codabar Coding Enable?
Enter:
cbrena^.
Response: CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding Enable
(CBRENA) is 1, or on.
Example: What is the device’s current setting for Codabar Coding Enable?
Enter:
cbrena?.
Response: CBRENA1[ACK]
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on.
Example: What are the device’s settings for all Codabar selections?
Enter:
cbr?.
Response: CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
9 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Serial Trigger Commands
You can activate and deactivate the scanner with serial trigger commands. The
trigger is activated and deactivated by sending the following commands:
Activate: SYN T CR
Deactivate: SYN U CR
The scanner scans until a bar code has been read or until the deactivate com-
mand is sent. The scanner can also be set to turn itself off after a specified time
Read Time-Out
Use this selection to set a time-out (in milliseconds) of the scanner’s trigger
when using serial commands to trigger the scanner. Once the scanner has
timed out, you can activate the scanner either by pressing the trigger or
using a serial trigger command. After scanning the Read Time-Out bar
code, set the time-out duration (from 0-300,000 milliseconds) by scanning
Read Time-Out
Resetting the Standard Product Defaults
If you aren’t sure what programming options are in your scanner, or you’ve
changed some options and want the factory default settings restored, scan the
Standard Product Default Settings bar code below.
Standard Product Default Settings
9 - 4
Download from Www.Somanuals.com. All Manuals Search And Download.
The charts on the following pages list the factory default settings for each of the
commands (indicated by an asterisk (*) on the programming pages).
9 - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Commands
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Product Default Settings
Setting Custom
Defaults
Set Custom Defaults MNUCDF
Save Custom
Defaults
DEFALT
DEFALT
DEFOVR
DEFALT
Resetting the
Custom Defaults
Activate Custom
Defaults
Resetting the Factory
Defaults
Remove Custom
Defaults
Activate Defaults
Programming the Interface
Plug and Play Codes Keyboard Wedge:
PAP_AT
IBM PC AT and
Compatibles with
CR suffix
IBM PS2 Keyboard
RS232 Serial Port
PAPPS2
PAP232
PAPP5B
Plug and Play Codes: IBM Port 5B
RS485
Interface
IBM Port 9B
HHBCR-1 Interface
PAP9B1
PAPP17
PAP9B2
IBM Port 17
Interface
IBM Port 9B
HHBCR-2 Interface
OPOS Mode
OPOS Mode
PAPOPS
PAPSPH
Plug and Play Codes:
IBM SurePos
USB IBM SurePos
Handheld
USB IBM SurePos
Tabletop
PAPSPT
REMIFC1
REMIFC0
IBM Secondary
Interface
* Enable Secondary
Interface
Disable Secondary
Interface
9 - 6
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Plug and Play Codes:
USB
USB Keyboard (PC)
PAP124
PAP125
USB Keyboard
(Mac)
USB Japanese
Keyboard (PC)
PAP134
USB HID
PAP131
HID Fallback Mode
HID Fallback Mode
(Range 0-60 *5
minutes
USBFTO
9 - 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
USB Serial
Commands
USB Serial
PAP130
Emulation for
Windows XP,
Windows Server
2003, and later
USB Serial
Emulation for
Windows 2000
CTS/RTS Emulation
On
USBCTS1
USBCTS0
USBACK1
CTS/RTS Emulation
Off*
ACK/NAK Mode On
ACK/NAK Mode Off* USBACK0
Communication
Timeout
232DLK#####
(Range 0-65535)
*2000 ms
Timeout Retries
HSTRTY
Communication
Timeout Beeper -
Off
HSTTOA0
*Communication
Timeout Beeper -
On
HSTTOA1
NAK Retries
(Range 0-255) *0
HSTRTN###
BELCAN1
BEL/CAN Mode On
BEL/CAN Mode Off* BELCAN0
9 - 8
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Plug and Play Codes
Verifone Ruby
Terminal
PAPRBY
Gilbarco Terminal
PAPGLB
PAPBIO
Honeywell Bioptic
Aux Port
Datalogic Magellan
Bioptic Aux Port
PAPMAG
PAPNCR
PAPWNX
PAPBTL
NCR Bioptic Aux
Port
Wincor Nixdorf
Terminal
Wincor Nixdorf
Beetle
Wincor Nixdorf
RS232 Mode A
PAPWMA
KBDCTY0
Program Keyboard
Country
*U.S.A.
Albania
KBDCTY35
KBDCTY91
KBDCTY81
KBDCTY80
KBDCTY82
KBDCTY1
Arabic
Azeri (Cyrillic)
Azeri (Latin)
Belarus
Belgium
Bosnia
KBDCTY33
KBDCTY16
KBDCTY59
KBDCTY52
KBDCTY53
KBDCTY54
Brazil
Brazil (MS)
Bulgaria (Cyrillic)
Bulgaria (Latin)
Canada (French
legacy)
Canada (French)
KBDCTY18
KBDCTY55
Canada
(Multilingual)
China
KBDCTY92
9 - 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Croatia
Czech
KBDCTY32
KBDCTY15
KBDCTY40
Czech
(Programmers)
Czech (QWERTY)
Czech (QWERTZ)
Denmark
KBDCTY39
KBDCTY38
KBDCTY8
KBDCTY11
KBDCTY41
KBDCTY83
KBDCTY2
KBDCTY3
KBDCTY84
KBDCTY4
KBDCTY17
KBDCTY64
KBDCTY61
KBDCTY65
KBDCTY62
KBDCTY63
KBDCTY66
KBDCTY60
KBDCTY12
Dutch (Netherlands)
Estonia
Faeroese
Finland
France
Gaelic
Germany
Greek
Greek (220 Latin)
Greek (220)
Greek (319 Latin)
Greek (319)
Greek (Latin)
Greek (MS)
Greek (Polytonic)
Hebrew
Hungarian (101 key) KBDCTY50
Hungary
Iceland
KBDCTY19
KBDCTY75
KBDCTY73
KBDCTY56
KBDCTY5
Ireland
Italian (142)
Italy
Japan ASCII
Kazakh
Korea
KBDCTY28
KBDCTY78
KBDCTY93
9 - 10
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Kyrgyz (Cyrillic)
Latin America
Latvia
KBDCTY79
KBDCTY14
KBDCTY42
KBDCTY43
KBDCTY44
KBDCTY45
KBDCTY34
KBDCTY74
KBDCTY86
KBDCTY9
Latvia (QWERTY)
Lithuania
Lithuania (IBM)
Macedonia
Malta
Mongolian (Cyrillic)
Norway
Poland
KBDCTY20
KBDCTY57
KBDCTY58
Polish (214)
Polish
(Programmers)
Portugal
KBDCTY13
KBDCTY25
KBDCTY26
KBDCTY67
Romania
Russia
Russian (MS)
Russian (Typewriter) KBDCTY68
SCS
KBDCTY21
KBDCTY37
KBDCTY36
KBDCTY22
Serbia (Cyrillic)
Serbia (Latin)
Slovakia
Slovakia (QWERTY) KBDCTY49
Slovakia (QWERTZ)
Slovenia
KBDCTY48
KBDCTY31
KBDCTY10
KBDCTY51
KBDCTY23
Spain
Spanish variation
Sweden
Switzerland (French) KBDCTY29
Switzerland
(German)
KBDCTY6
9 - 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Tatar
KBDCTY85
KBDCTY94
KBDCTY27
KBDCTY24
KBDCTY76
KBDCTY7
Thailand
Turkey F
Turkey Q
Ukrainian
United Kingdom
United Stated
(Dvorak right)
KBDCTY89
United States
(Dvorak left)
KBDCTY88
KBDCTY87
KBDCTY30
United States
(Dvorak)
United States
(International)
Uzbek (Cyrillic)
Vietnam
KBDCTY77
KBDCTY95
Keyboard Wedge Modifiers
ALT Mode
*Off
KBDALT0
KBDALT6
KBDALT7
KBDSTY0
KBDSTY1
KBDSTY2
KBDSTY7
3 Characters
4 Characters
*Regular
Keyboard Style
Caps Lock
Shift Lock
Autocaps via
NumLock
Emulate External
Keyboard
KBDSTY5
9 - 12
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Keyboard Conversion *Keyboard
Conversion Off
KBDCNV0
Convert all
KBDCNV1
Characters to Upper
Case
Convert all
KBDCNV1
Characters to Lower
Case
Keyboard Modifiers
*Control + ASCII Off
KBDCAS0
KBDCAS1
DOS Mode Control
+ ASCII
Windows Mode
Control + ASCII
KBDCAS2
KBDCAS3
KBDNPS0
Windows Mode
Prefix/Suffix Off
*Numeric Keypad
Off
Numeric Keypad On
KBDNPS1
KBDDLY##
Inter-Scan Code
Delay
Inter-Scan Code
Delay
*0 (Range 1-30
msecs)
<F0> Break
Character
Suppress <F0>
Break Character
KBDF0B0
KBDF0B1
KBDDFT
*Transmit <F0>
Break Character
Keyboard Wedge
Defaults
Reset Keyboard
Wedge Defaults
9 - 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
RS-232 Modifiers
RS232 Baud Rate
300 BPS
232BAD0
232BAD1
232BAD2
232BAD3
232BAD4
232BAD5
232BAD6
232BAD7
232BAD8
232BAD9
600 BPS
1200 BPS
2400 BPS
4800 BPS
*9600 BPS
19200 BPS
38400 BPS
57600 BPS
115200 BPS
9 - 14
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Word Length: Data
Bits, Stop Bits, and
Parity
7 Data, 1 Stop,
Parity Even
232WRD3
232WRD0
7 Data, 1 Stop,
Parity None
7 Data, 1 Stop,
Parity Odd
232WRD6
232WRD4
232WRD1
232WRD7
232WRD5
232WRD2
232WRD8
232WRD9
232WRD10
232WRD11
232WRD12
232WRD13
232WRD14
7 Data, 2 Stop,
Parity Even
7 Data, 2 Stop,
Parity None
7 Data, 2 Stop,
Parity Odd
8 Data, 1 Stop,
Parity Even
*8 Data, 1 Stop,
Parity None
8 Data, 1 Stop,
Parity Odd
7 Data, 1 Stop,
Parity Space
7 Data, 2 Stop,
Parity Space
8 Data, 1 Stop,
Parity Space
7 Data, 1 Stop,
Parity Mark
7 Data, 2 Stop,
Parity Mark
8 Data, 1 Stop,
Parity Mark
9 - 15
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
RS232 Handshaking
*RTS/CTS Off
232CTS0
232CTS1
Flow Control, No
Timeout
Character-Based
Flow Control, No
Timeout
232CTS7
Two-Direction Flow
Control
232CTS2
232CTS3
232CTS9
Flow Control with
Timeout
Character-Based
Flow Control with
Timeout
RS232 Timeout
(Range 1-5100)
*1000 ms
232DEL####
*XON/XOFF Off
XON/XOFF On
*ACK/NAK Off
ACK/NAK On
232XON0
232XON1
232ACK0
232ACK1
Communication
Timeout
232DLK#####
(Range 1-65535)
*2000 ms
Communication
Timeout Beeper -
Off
HSTTOA0
HSTTOA1
BELCAN1
*Communication
Timeout Beeper -
On
BEL/CAN Mode On
*BEL/CAN Mode Off BELCAN0
RS232 Defaults
NCR Modifiers
Reset RS232
Defaults
232DFT
9 - 16
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
NCR ACK/NAK
*NCR ACK/NAK Off
NCR ACK/NAK On
*Transmit
NCRACK0
NCRACK1
NCRBCC1
NCRBCC0
NCRPR2##
NCRSF2##
NCRBCP1
Block Check
Character
Don’t Transmit
NCR Prefix
NCR Prefix/Suffix
NCR Suffix
Transmit Prefix/
Suffix
*Don’t Transmit
Prefix/Suffix
NCRBCP0
NCR NOF (Not-on-
File) Error
On
NCRRAZ1
NCRRAZ0
232PKT0
*Off
Scanner to Bioptic
Communication
*Packet Mode Off
Packet Mode On
*ACK/NAK Off
ACK/NAK On
232PKT2
232ACK0
232ACK1
232DLK#####
Communication
Timeout
(Range 1-65535)
*2000 ms
Input/Output Selections
Power Up Beeper
Power Up Beeper
Off - Scanner
BEPPWR0
BEPPWR1
*Power Up Beeper
On - Scanner
Beep on BEL
Character
Beep on BEL On
BELBEP1
BELBEP0
BEPBEP0
BEPBEP1
BEPLVL0
BEPLVL1
BEPLVL2
BEPLVL3
*Beep on BEL Off
Beeper - Good Read
Off
*On
Beeper Volume -
Good Read
Off
Low
Medium
*High
9 - 17
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Beeper Pitch - Good
Read (Frequency)
Low (1600 Hz)
BEPFQ11600
BEPFQ12350
BEPFQ14200
BEPWHN1
*Medium (2350 Hz)
High (4200 Hz)
Beeper - Transmit
Order
*Before
Transmission
After Transmission
*Razz (100 Hz)
Medium (2000 Hz)
High (4200 Hz)
*Normal Beep
BEPWHN2
BEPFQ2100
BEPFQ22000
BEPFQ24200
BEPBIP0
Beeper Pitch - Error
(Frequency)
Beeper Duration -
Good Read
Short Beep
BEPBIP1
Number of Beeps -
Good Read
Range 1 - 9 (*1)
BEPRPT#
Number of Beeps -
Error
Range 1 - 9 (*1)
BEPERR#
9 - 18
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
LED Settings
*Red LED Off
Green LED Off
LEDFN10
LEDFN20
LEDFN11
Red LED On with
Good Scan
*Green LED On with
Good Scan
LEDFN21
LEDFN12
LEDFN22
LEDFN14
LEDFN24
Red LED On with
Laser
Green LED On with
Laser
Red LED On when
CodeGate Disabled
Green LED On
when CodeGate
Disabled
Red LED On when
In-Stand
LEDFN18
Green LED On
when In-Stand
LEDFN28
Red LED On with
CTS
LEDFN1128
LEDFN2128
Green LED On with
CTS
LED Brightness
Red Off
LEDIN10
LEDIN20
LEDIN11
LEDIN21
LEDIN12
LEDIN22
LEDIN13
LEDIN23
Green Off
Red Low
Green Low
Red Medium
Green Medium
*Red High
*Green High
9 - 19
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
In-Stand and Out-of-
Stand Settings
In-Stand Defaults
AISDFT
Out-of-Stand
Defaults
AOSDFT
Presentation Mode
Out-of-Stand
PAPPM1
PAPPM2
Presentation Mode
with CodeGate Out-
of-Stand
Manual Activation
Mode Off In-Stand
AISMEN0
AISMEN1
AOSMEN0
*Manual Activation
Mode On In-Stand
Manual Activation
Mode Off Out-of-
Stand
*Manual Activation
Mode On Out-of-
Stand
AOSMEN1
AISMGD0
AISMGD1
AOSMGD0
Do Not End Manual
Activation After
Good Read In-Stand
*End Manual
Activation After
Good Read In-Stand
Do Not End Manual
Activation After
Good Read Out-of-
Stand
*End Manual
Activation After
Good Read Out-of-
Stand
AOSMGD1
Laser Timeout -
Trigger Hold In-
Stand
AISMPT#####
(Range 1 - 65525)
*5000 ms
9 - 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
In-Stand and Out-of-
Stand Settings
(continued)
Laser Timeout -
Trigger Release In-
Stand
(Range 1 - 65525)
*0 ms
AISMRT#####
AOSMPT#####
AOSMRT#####
Laser Timeout -
Trigger Hold Out-of-
Stand
(Range 1 - 65525)
*30000 ms
Laser Timeout -
Trigger Release Out-
of-Stand
(Range 1 - 65525)
*0 ms
*CodeGate Off In-
Stand
AISCGD0
AISCGD1
AOSCGD0
AOSCGD1
AISOEN0
AOSOEN1
CodeGate On In-
Stand
CodeGate Off Out-
of-Stand
*CodeGate On Out-
of-Stand
Object Detection
Mode Off In-Stand
Object Detection
Mode On Out-of-
Stand
*Object Detection
Mode Off Out-of-
Stand
AOSOEN0
*Object Detection
Mode On In-Stand
AISOEN1
AISOGD0
Do Not End Object
Detection After
Good Read In-Stand
9 - 21
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
In-Stand and Out-of-
Stand Settings
(continued)
*End Object
Detection After
Good Read In-Stand
AISOGD1
Do Not End Object
Detection After
Good Read Out-of-
Stand
AOSOGD0
*End Object
Detection After
Good Read Out-of-
Stand
AOSOGD1
Object Detection
Laser Timeout In-
Stand
AISODT#####
(Range 1 - 65525)
*5000 ms
Object Detection
Laser Timeout Out-
of-Stand
AOSODT#####
(Range 1 - 65525)
*5000 ms
*Object Detection
Distance - Short In-
Stand
AISRNG2
AISRNG1
AOSRNG2
AOSRNG1
Object Detection
Distance - Long In-
Stand
Object Detection
Distance - Short
Out-of-Stand
*Object Detection
Distance - Long Out-
of-Stand
9 - 22
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Character Activation
Mode
*Off
HSTCEN0
HSTCEN1
HSTACH##
HSTCGD0
On
Activation Character
Do Not End
Character Activation
After Good Read
*End Character
Activation After
Good Read
HSTCGD1
Character Activation
Laser Timeout
(Range 1 - 65525)
*5000 ms
HSTCDT#####
Character
Deactivation Mode
*Off
On
HSTDEN0
HSTDEN1
HSTDCH##
Deactivation
Character
Reread Delay
Short (500 ms)
*Medium (750 ms)
Long (1000 ms)
DLYRRD500
DLYRRD750
DLYRRD1000
DLYRRD2000
Extra Long (2000
ms)
User-Specified
Reread Delay
Range 0 - 30,000
ms
DLYRRD#####
Output Sequence
Editor
Enter Sequence
SEQBLK
Default Sequence
SEQDFT
Sequence Timeout
(Range 1 - 65535)
*5000 ms
SEQDLY#####
Sequence Match
Beeper
*On
Off
SEQBEP1
SEQBEP0
SEQTTS1
Partial Sequence
Transmit Partial
Sequence
*Discard Partial
Sequence
SEQTTS0
9 - 23
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Require Output
Sequence
Required
SEQ_EN2
SEQ_EN1
SEQ_EN0
SHWNRD1
SHWNRD0
On/Not Required
*Off
On
No Read
*Off
Prefix/Suffix Selections
Add CR Suffix to All Symbologies
VSUFCR
PREBK2##
PRECL2
Prefix
Add Prefix
Clear One Prefix
Clear All Prefixes
Add Suffix
PRECA2
SUFBK2##
SUFCL2
Suffix
Clear One Suffix
Clear All Suffixes
SUFCA2
KBDEXT0
Transmit Alternate
Extended ASCII
Characters
*Transmit Alternate
Extended ASCIi
Transmit Normal
Extended ASCIi
KBDEXT1
Function Code
Transmit
*Enable
Disable
*None
RMVFNC0
RMVFNC1
HSTXRC0
HSTXRC1
Communication
Check Character
LRC Starts on 1st
Character
LRC Starts on 2nd
Character
HSTXRC2
CRC
HSTXRC3
DLYCHR##
Intercharacter Delay
Range 0 - 1000
(5ms increments)
User Specified
Intercharacter Delay
Delay Length
0 - 1000 (5ms
increments)
DLYCRX##
DLY_XX##
Character to Trigger
Delay
9 - 24
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Interfunction Delay
Intermessage Delay
Range 0 - 1000
(5ms increments)
DLYFNC##
Range 0 - 1000
DLYMSG##
(5ms increments)
Data Formatter Selections
Data Format Editor *Default Data
DFMDF3
Format (None)
Enter Data Format
DFMBK3##
DFMCL3
Clear One Data
Format
Clear All Data
Formats
DFMCA3
Data Formatter
Data Formatter Off
DFM_EN0
DFM_EN1
*Data Formatter On,
Not Required,
Keep Prefix/Suffix
Data Format
Required,
Keep Prefix/Suffix
DFM_EN2
DFM_EN3
DFM_EN4
DFMDEC0
DFMDEC1
Data Formatter On,
Not Required,
Drop Prefix/Suffix
Data Format
Required,
Drop Prefix/Suffix
Data Format Non-
Match Error Tone
*Data Format Non-
Match Error Tone
On
Data Format Non-
Match Error Tone
Off
9 - 25
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Primary/Alternate
Data Formats
Primary Data
Format
ALTFNM0
Data Format 1
Data Format 2
Data Format 3
ALTFNM1
ALTFNM2
ALTFNM3
VSAF_0
Single Scan Data
Format Change
Single Scan-Primary
Data Format
Single Scan-Data
Format 1
VSAF_1
VSAF_2
VSAF_3
Single Scan-Data
Format 2
Single Scan-Data
Format 3
Symbologies
All Symbologies
All Symbologies Off
All Symbologies On
ALLENA0
ALLENA1
CBRDFT
Codabar
Default All Codabar
Settings
Off
CBRENA0
CBRENA1
CBRSSX0
CBRSSX1
*On
Codabar Start/Stop
Char.
*Don’t Transmit
Transmit
9 - 26
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Codabar Check
Char.
*No Check Char.
CBRCK20
CBRCK21
Validate Modulo 16,
But Don’t Transmit
Validate Modulo 16,
and Transmit
CBRCK22
CBRCK23
Validate Modulo 7
CD, But Don’t
Transmit
Validate Modulo 7
CD, and Transmit
CBRCK24
CBRCK25
CBRCK26
Validate CLSI, But
Don’t Transmit
Validate CLSI, and
Transmit
Codabar
Concatenation
*Off
CBRCCT0
CBRCCT1
CBRCCT2
DLYCCT
On
Require
Concatenation
Timeout
Codabar
Range (0 - 10) *0
CBRVOT##
Redundancy
Codabar Message
Length
Minimum (1 - 80) *3 CBRMIN##
Maximum (1 - 80)
*80
CBRMAX##
Code 39
Default All Code 39
Settings
C39DFT
Off
C39ENA0
C39ENA1
C39SSX0
C39SSX1
*On
Code 39 Start/Stop
Char.
*Don’t Transmit
Transmit
9 - 27
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Code 39 Check Char. *No Check Char.
C39CK20
C39CK21
Validate, But Don’t
Transmit
Validate,
and Transmit
C39CK22
Code 39
Redundancy
Range (0 - 10) *0
C39VOT##
Code 39 Message
Length
Minimum (1 - 80) *3 C39MIN##
Maximum (1 - 80)
*80
C39MAX##
Code 32
Pharmaceutical
(PARAF)
*Off
On
C39B320
C39B321
Code 39 Full ASCII
*Off
On
C39ASC0
C39ASC1
I25DFT
Interleaved 2 of 5
Default All
Interleaved
2 of 5 Settings
Off
I25ENA0
I25ENA1
I25NUL0
I25NUL1
I25CK20
I25CK21
*On
NULL Characters
*Off
On
Interleaved 2 of 5
Check Digit
*No Check Char.
Validate, But Don’t
Transmit
Validate, and
Transmit
I25CK22
Interleaved 2 of 5
Redundancy
Range (0 - 10) *0
I25VOT##
Interleaved 2 of 5
Message Length
Minimum (1 - 80) *6 I25MIN##
Maximum (1 - 80)
*80
I25MAX##
9 - 28
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
NEC 2 of 5
Default All NEC
2 of 5 Settings
N25DFT
*Off
N25ENA0
N25ENA1
N25CK20
N25CK21
On
NEC 2 of 5 Check
Digit
*No Check Char.
Validate, But Don’t
Transmit
Validate, and
Transmit
N25CK22
NEC 2 of 5
Redundancy
Range (0 - 10) *0
N25VOT##
NEC 2 of 5 Message
Length
Minimum (1 - 80) *3 N25MIN##
Maximum (1 - 80)
*80
N25MAX##
Code 93
Default All Code 93
Settings
C93DFT
Off
C93ENA0
C93ENA1
C93VOT##
*On
Code 93
Redundancy
Range (0 - 10) *0
Code 93 Message
Length
Minimum (1 - 80) *3 C93MIN##
Maximum (1 - 80)
*80
C93MAX##
Straight 2 of 5
Industrial
Default All Straight 2
of 5 Industrial
Settings
R25DFT
*Off
R25ENA0
R25ENA1
R25VOT##
On
Straight 2 of 5
Industrial
Redundancy
Range (0 - 10) *0
Straight 2 of 5
Industrial Message
Length
Minimum (1 - 80) *3 R25MIN##
Maximum (1 - 80)
*80
R25MAX##
9 - 29
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Straight 2 of 5 IATA
Default All Straight 2
of 5 IATA
A25DFT
Settings
Straight 2 of 5 IATA
*Off
A25ENA0
A25ENA1
A25VOT##
On
Straight 2 of 5 IATA
Redundancy
Range (0 - 10) *0
Straight 2 of 5 IATA
Message Length
Minimum (1 - 80)
*13
A25MIN##
A25MAX##
X25DFT
Maximum (1 - 80)
*15
Matrix 2 of 5
Default All Matrix 2
of 5
Settings
*Off
X25ENA0
X25ENA1
X25VOT##
On
Matrix 2 of 5
Redundancy
Range (0 - 10) *0
Matrix 2 of 5
Message Length
Minimum (1 - 80) *3 X25MIN##
Maximum (1 - 80)
*80
X25MAX##
Matrix 2 of 5 Check
Char.
*No Check Char.
X25CK20
X25CK21
Validate, But Don’t
Transmit
Validate and
Transmit
X25CK22
C11DFT
Code 11
Default All Code 11
Settings
*Off
On
C11ENA0
C11ENA1
9 - 30
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Code 11 Check
Digits Required
1 Check Digit
Required
C11CK20
C11CK21
C11CK22
C11CK23
*2 Check Digits
Required
Auto Select Check
Digits Required
Check Digit
Validation
Validate and
Transmit One Check
Digit
Validate and
Transmit Two Check
Digits
C11CK24
C11CK25
C11VOT##
Validate and
Transmit Auto Select
Check Digits
Code 11
Redundancy
Range (0 - 10) *0
Code 11 Message
Length
Minimum (1 - 80) *3 C11MIN##
Maximum (1 - 80)
*80
C11MAX##
Code 128
Default All Code 128 128DFT
Settings
Off
128ENA0
128ENA1
128GSE0
128GSE1
128VOT##
*On
128 Group Separator
Output
*Off
On
Code 128
Redundancy
Range (0 - 10) *0
Code 128 Message
Length
Minimum (1 - 80) *1 128MIN##
Maximum (1 - 80)
*80
128MAX##
ISBT 128
*Off
On
ISBENA0
ISBENA1
DLYCCT
Concatenation
Timeout
9 - 31
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
ISBT128 Predefined
Concatenation
Sequences
* Donation ID
ISBPCS0
ISBPCS1
ISBPCS2
Number (001)
and ABO/RhD Blood
Groups (002)
Donation ID Number
(001) and
Donor ID Number
(019)
Donation ID Number
(001) and
Confidential Unit
Exclusion Status
Product Code (003)
and Expiration Date
(Form 1)
ISBPCS3
ISBPCS4
ISBPCS5
ISBPCS6
Product Code (003)
and Expiration Date
(Form 2)
Product Code (003)
and Expiration Date
(Form 3)
Product Code (003)
and Expiration Date
(Form 4)
ISBT 128 Predefined
Concatenation
Sequences On/Off
*Off
ISBPCE0
ISBPCE1
Allow Predefined
Sequence
Require Predefined
Sequence
ISBPCE2
9 - 32
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
ISBT 128 User-
Defined
Concatenation
Sequences
1st Left Identifier (0-
255) *0
ISBUL1##
2nd Left Identifier (0- ISBUL2##
255) *0
1st Right Identifier
(0-255) *0
ISBUR1##
2nd Right Identifier
(0-255) *0
ISBUR2##
ISBT 128 User-
Defined
Concatenation
Sequences On/Off
*Off
ISBUCE0
ISBUCE1
Allow User-Defined
Sequence
Require User-
ISBUCE2
Defined Sequence
Content Verification
Transmit Identifiers
Flag Conversion
GS1-128
*Off
On
ISBXM00
ISBXM01
ISBXM10
ISBXM11
ISBXM20
ISBXM21
GS1DFT
Off
*On
*Off
On
Default All GS1-128
Settings
*On
Off
GS1ENA1
GS1ENA0
GS1EMU0
GS1EMU1
GS1-128 Application
Identifier Parsing
*Off
Transmit Without
Identifiers
Transmit With
Identifiers
GS1EMU2
GS1VOT##
GS1-128
Redundancy
Range (0 - 10) *0
GS1-128 Message
Length
Minimum (1 - 80) *3 GS1MIN
Maximum (0 - 80)
*80
GS1MAX
9 - 33
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
Telepen
Default All Telepen
Settings
TELDFT
*Off
On
TELENA0
TELENA1
Telepen Output
*AIM Telepen Output TELOLD0
Original Telepen
Output
TELOLD1
Telepen Redundancy Range (0 - 10) *0
TELVOT##
Telepen Message
Length
Minimum (1 - 80) *3 TELMIN##
Maximum (1 - 80)
*80
TELMAX##
UPC-A
Default All
UPADFT
UPC-A Settings
Off
UPAENA0
UPAENA1
UPANSX0
UPANSX1
UPACKX0
UPACKX1
UPAAD20
UPAAD21
UPAAD50
UPAAD51
UPAARQ0
UPAARQ1
DLYADD#####
*On
UPC-A Number
System
Off
*On
UPC-A Check Digit
Off
*On
UPC-A 2 Digit
Addenda
*Off
On
UPC-A 5 Digit
Addenda
*Off
On
UPC-A Addenda
Required
*Not Required
Required
Addenda Timeout
Range (0 - 65535)
*100
UPC-A Addenda
Separator
*Off
UPAADS0
UPAADS1
UPAVOT##
On
UPC-A Redundancy
Range (0 - 10) *0
9 - 34
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
UPC-A/EAN-13 with
Extended Coupon
Code
*Off
CPNENA0
Allow Concatenation CPNENA1
Require
Concatenation
CPNENA2
ARQSY40
ARQSY41
ARQSY50
UPC-A Number
System 4 Addenda
Required
* Don’t Require
Coupon Code
Require Coupon
Code
UPC-A Number
System 5 Addenda
Required
* Don’t Require
Coupon Code/
Addenda
Require 2 Digit
Addenda
ARQSY51
ARQSY52
ARQSY53
ARQSY54
ARQSY55
Require 5 Digit
Addenda
Require 2 or 5 Digit
Addenda
Require Coupon
Code
Require Coupon
Code or 2 Digit
Addenda
Require Coupon
Code or 5 Digit
Addenda
ARQSY56
ARQSY57
Require Coupon
Code, 2 Digit
Addenda, or 5 Digit
Addenda
Addenda Timeout
UPC-E0
Range (0 - 65535)
*100
DLYADD#####
UPEDFT
Default All UPC-E
Settings
Off
UPEEN00
UPEEN01
*On
9 - 35
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
UPC-E0 Expand
*Off
UPEEXP0
UPEEXP1
UPEEXN1
UPEEXN0
UPECKX0
UPECKX1
UPENSX0
UPENSX1
UPEAD21
On
UPC-E0 Number
System
*On
Off
UPC-E0 Check Digit
*Off
On
UPC-E0 Leading
Zero
*Off
On
UPC-E0 Addenda
2 Digit Addenda On
*2 Digit Addenda Off UPEAD20
5 Digit Addenda On UPEAD51
*5 Digit Addenda Off UPEAD50
UPC-E0 Addenda
Required
Required
UPEARQ1
*Not Required
UPEARQ0
Addenda Timeout
Range (0 - 65535)
*100
DLYADD#####
UPC-E0 Addenda
Separator
On
UPEADS1
UPEADS0
UPEVOT##
*Off
UPC-E0
Range (0 - 10) *1
Redundancy
EAN/JAN-13
Default All EAN/
JAN Settings
E13DFT
Off
E13ENA0
E13ENA1
E13CKX0
E13CKX1
E13AD21
*On
EAN/JAN-13 Check
Digit
Off
*On
EAN/JAN-13 2 Digit
Addenda
2 Digit Addenda On
*2 Digit Addenda Off E13AD20
5 Digit Addenda On E13AD51
*5 Digit Addenda Off E13AD50
EAN/JAN-13
Addenda Required
*Not Required
Required
E13ARQ0
E13ARQ1
9 - 36
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
EAN-13 Beginning
with 2 Addenda
Required
* Don’t Require 2
Digit Addenda
ARQSY20
ARQSY21
ARQ2900
ARQ2901
ARQ3780
ARQ3781
ARQ3782
ARQ3783
ARQ4140
ARQ4141
ARQ4142
ARQ4143
ARQ4340
ARQ4341
ARQ4342
ARQ4343
Require 2 Digit
Addenda
EAN-13 Beginning
with 290 Addenda
Required
* Don’t Require 5
Digit Addenda
Require 5 Digit
Addenda
EAN-13 Beginning
with 378/379
Addenda Required
* Don’t Require
Addenda
Require 2 Digit
Addenda
Require 5 Digit
Addenda
Require 2 or 5 Digit
Addenda
EAN-13 Beginning
with 414/419
Addenda Required
* Don’t Require
Addenda
Require 2 Digit
Addenda
Require 5 Digit
Addenda
Require 2 or 5 Digit
Addenda
EAN-13 Beginning
with 434/439
Addenda Required
* Don’t Require
Addenda
Require 2 Digit
Addenda
Require 5 Digit
Addenda
Require 2 or 5 Digit
Addenda
9 - 37
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
EAN-13 Beginning
with 977 Addenda
Required
* Don’t Require 2
Digit Addenda
ARQ9770
ARQ9771
ARQ9780
ARQ9781
ARQ9790
ARQ9791
DLYADD#####
Require 2 Digit
Addenda
EAN-13 Beginning
with 978 Addenda
Required
* Don’t Require 5
Digit Addenda
Require 5 Digit
Addenda
EAN-13 Beginning
with 979 Addenda
Required
* Don’t Require 5
Digit Addenda
Require 5 Digit
Addenda
Addenda Timeout
Range (0 - 65535)
*100
EAN/JAN-13
Addenda
Separator
*Off
On
E13ADS0
E13ADS1
EAN/JAN-13
Redundancy
Range (0 - 10) *0
E13VOT##
ISBN Translate
*Off
On
E13ISB0
E13ISB1
E13I131
Convert to 13-Digit
On
*Convert to 13-Digit
Off
E13I130
Reformat On
*Reformat Off
*Off
E13IBR1
E13IBR0
E13ISS0
E13ISS1
E13ISR1
E13ISR0
ISSN Translate
On
Reformat On
*Reformat Off
9 - 38
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
EAN/JAN-8
Default All EAN/
JAN 8 Settings
EA8DFT
Off
EA8ENA0
EA8ENA1
EA8CKX0
EA8CKX1
*On
Off
EAN/JAN-8 Check
Digit
*On
EAN/JAN-8 Addenda *2 Digit Addenda Off EA8AD20
2 Digit Addenda On EA8AD21
*5 Digit Addenda Off EA8AD50
5 Digit Addenda On
*Not Required
Required
EA8AD51
EAN/JAN-8 Addenda
Required
EA8ARQ0
EA8ARQ1
DLYADD#####
Addenda Timeout
Range (0 - 65535)
*100
EAN/JAN-8 Addenda
Separator
*Off
EA8ADS0
EA8ADS1
EA8VOT##
On
EAN/JAN-8
Range (0 - 10) *0
Redundancy
MSI
Default All MSI
Settings
MSIDFT
*Off
On
MSIENA0
MSIENA1
9 - 39
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
MSI Check Character *Validate Type 10,
but Don’t Transmit
MSICHK0
MSICHK1
MSICHK2
Validate Type 10 and
Transmit
Validate 2 Type 10
Chars, but Don’t
Transmit
Validate 2 Type 10
Chars and Transmit
MSICHK3
MSICHK4
Validate Type 10
then Type 11 Char,
but Don’t Transmit
Validate Type 10
then Type 11 Char
and Transmit
MSICHK5
MSICHK6
Disable MSI Check
Characters
MSI Redundancy
Range (0 - 10) *0
MSIVOT##
MSIMIN##
MSIMAX##
MSI Message Length Minimum (1 - 80) *3
Maximum (1 - 80)
*80
Plessey Code
Default All
Plessey Code
Settings
PLSDFT
Off
PLSENA0
PLSENA1
PLSCHK0
PLSCHK1
*On
Plessey Check Char.
*No Check Char.
Validate, But Don’t
Transmit
Validate,
and Transmit
PLSCHK2
PLSVOT##
Plessey Redundancy Range (0 - 10) *0
Plessey Message
Length
Minimum (1 - 80) *3 PLSMIN##
Maximum (1 - 80)
*80
PLSMAX##
9 - 40
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
GS1 DataBar
Default All
RSSDFT
Omnidirectional
GS1 DataBar
Omnidirectional
Settings
Off
RSSENA0
RSSENA1
RSSVOT##
*On
GS1 DataBar
Omnidirectional
Redundancy
Range (0 - 10) *0
GS1 DataBar Limited Default All GS1
DataBar Limited
RSLDFT
Settings
Off
RSLENA0
RSLENA1
RSLVOT##
*On
GS1 DataBar Limited
Redundancy
Range (0 - 10) *0
GS1 DataBar
Expanded
Default All GS1
DataBar
RSEDFT
Expanded Settings
Off
RSEENA0
RSEENA1
RSEVOT##
*On
GS1 DataBar
Expanded
Redundancy
Range (0 - 10) *0
GS1 DataBar
Expanded Msg.
Length
Minimum (1 - 80) *3
RSEMIN##
RSEMAX##
Maximum (1 - 80)
*80
Trioptic Code
*Off
On
TRIENA0
TRIENA1
9 - 41
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Command
# Indicates a numeric
entry
Setting
* Indicates default
Selection
Page
GS1 Emulation
GS1-128 Emulation
EANEMU1
EANEMU2
GS1 DataBar
Emulation
GS1 Code
Expansion Off
EANEMU3
EANEMU4
EANEMU0
EAN8 to EAN13
Conversion
*GS1 Emulation Off
Postal Codes
China Post (Hong
Kong 2 of 5)
Default All China
Post (Hong Kong 2
of 5) Settings
CPCDFT
*Off
CPCENA0
CPCENA1
CPCVOT##
On
China Post (Hong
Kong 2 of 5)
Redundancy
Range (0 - 10) *0
China Post (Hong
Kong 2 of 5) Msg.
Length
Minimum (1 - 80) *3
CPCMIN##
CPCMAX##
Maximum (1 - 80)
*80
Serial Trigger Commands
Read Time-Out 0 - 300,000
*30,000 ms
TRGSTO####
9 - 42
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Product Specifications
Voyager 1250gAP Scanner Product
Specifications
Parameter
Specification
Mechanical
Height
6.63 in. (168mm)
3.22 in. (88mm)
2.45 in. (62mm)
4.69 oz. (133g)
Length
Width
Weight
Electrical
Input Voltage
Operating Power
Standby Power
Environmental
Operating Temperature
Storage Temperature
Humidity
5V + 5%
700mW; 140 mA (typical) @ 5V
425mW; 85 mA (typical) @ 5V
32°F to 104°F (0°C to 40°C)
-4°F to 140°F (-20°C to 60°C)
5 to 95% non-condensing
Operational after 30 drops to concrete from 5 ft.
(1.5m)
Drop
Environmental Sealing
Light Immunity
ESD
IP41
75,000 lux (direct sunlight)
15kV Air, 8kV contact
Scan Performance
Scan Pattern
Single scan line
Scan Angle
Horizontal: 30°
Scan Speed
100 scan lines per second
20% minimum reflectance difference
60°, 60°
Print Contrast
Pitch, Skew
Decode Capabilities
Reads standard 1D and GS1 DataBar symbologies
10 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
10 - 6
Download from Www.Somanuals.com. All Manuals Search And Download.
11
Maintenance
Repairs
Repairs and/or upgrades are not to be performed on this product. These ser-
Maintenance
Your device provides reliable and efficient operation with a minimum of care.
Although specific maintenance is not required, the following periodic checks
ensure dependable operation:
Cleaning the Device:
Reading performance may degrade if the scanner’s window is not clean. If
the window is visibly dirty, or if the scanner isn’t operating well, clean the
window with a soft cloth or lens tissue dampened with water (or a mild
detergent- water solution). If a detergent solution is used, rinse with a
clean lens tissue dampened with water only.
The scanner and base’s housing may also be cleaned the same way.
Caution:
!
Do not submerge the scanner in water. The scanner’s
housing is not watertight.
Do not use abrasive wipes or tissues on the scanner’s
window – abrasive wipes may scratch the window. Never
use solvents (e.g., alcohol or acetone) on the housing or
window – solvents may damage the finish or the window.
Inspecting Cords and Connectors
Inspect the interface cable and connector for wear or other signs of dam-
age. A badly worn cable or damaged connector may interfere with scanner
operation. Contact your distributor for information about cable replace-
Replacing Cables
The standard interface cable is attached to the scanner with an 10-pin modular
connector. When properly seated, the connector is held in the scanner’s handle
by a flexible retention tab. The interface cable is designed to be field replace-
able.
11 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
Order replacement cables from Honeywell or from an authorized distributor.
When ordering a replacement cable, specify the cable part number of the
original interface cable.
Replacing an Interface Cable
1. Turn the power to the host system OFF.
2. Disconnect the scanner’s cable from the
terminal or computer.
3. Locate the small hole on the underside of
the scanner’s handle. This is the cable
release.
4. Straighten one end of a paper clip.
5. Insert the end of the paper clip into the small
hole and press in. This depresses the
retention tab, releasing the connector. Pull
the connector out while maintaining
pressure on the paper clip, then remove the
paper clip.
6. Replace with the new cable.
Insert the connector into the opening and press firmly. The connector is
keyed to go in only one way, and will click into place.
Troubleshooting a Voyager Scanner
The scanner automatically performs self-tests whenever you turn it on. If
your scanner is not functioning properly, review the following Troubleshoot-
ing Guide to try to isolate the problem.
Is the power on? Is the laser aimer on?
If the laser aimer isn’t illuminated, check that:
•
•
•
The cable is connected properly.
The host system power is on (if external power isn’t used).
The trigger works.
Is the scanner having trouble reading your symbols?
If the scanner isn’t reading symbols well, check that the scanner window is
clean and that the symbols:
•
•
•
Aren’t smeared, rough, scratched, or exhibiting voids.
Aren’t coated with frost or water droplets on the surface.
Are enabled in the scanner or in the decoder to which the scanner
connects.
Is the bar code displayed but not entered?
The bar code is displayed on the host device correctly, but you still have to
press a key to enter it (the Enter/Return key or the Tab key, for example).
11 - 2
Download from Www.Somanuals.com. All Manuals Search And Download.
•
You need to program a suffix. Programming a suffix enables the scanner
to output the bar code data plus the key you need (such as “CR”) to enter
1 for further information.
Does the scanner read the bar code incorrectly?
If the scanner reads a bar code, but the data is not displayed correctly on
the host screen:
•
The scanner may not be programmed for the appropriate terminal
interface.
For example, you scan “12345” and the host displays “@es%.”
Reprogram the scanner with the correct Plug and Play bar code. See
•
The scanner may not be programmed to output your bar code data
properly.
For example, you scan “12345” and the host displays “A12345B.”
Reprogram the scanner with the proper symbology selections. See
The scanner won’t read your bar code at all.
1. Scan the sample bar codes in the back of this manual. If the scanner
reads the sample bar codes, check that your bar code is readable.
If you aren’t sure what programming options have been set in the scanner,
or if you want the factory default settings restored, refer to Setting Custom
11 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
11 - 4
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Customer Support
Technical Assistance
If you need assistance installing or troubleshooting your device, please contact
us by using one of the methods below:
Knowledge Base: www.hsmknowledgebase.com
Our Knowledge Base provides thousands of immediate solutions. If the Knowl-
edge Base cannot help, our Technical Support Portal (see below) provides an
easy way to report your problem or ask your question.
Technical Support Portal: www.hsmsupportportal.com
The Technical Support Portal not only allows you to report your problem, but it
also provides immediate solutions to your technical issues by searching our
Knowledge Base. With the Portal, you can submit and track your questions
online and send and receive attachments.
Web form: www.hsmcontactsupport.com
You can contact our technical support team directly by filling out our online sup-
port form. Enter your contact details and the description of the question/prob-
lem.
For our latest contact information, please check our website at the link above.
Product Service and Repair
Honeywell International Inc. provides service for all of its products through ser-
vice centers throughout the world. To obtain warranty or non-warranty service,
and Repair to see your region’s instructions on how to obtain a Return Material
Authorization number (RMA #). You should do this prior to returning the product.
Limited Warranty
Honeywell International Inc. (“HII”) warrants its products to be free from defects
in materials and workmanship and to conform to HII’s published specifications
applicable to the products purchased at the time of shipment. This warranty
does not cover any HII product which is (i) improperly installed or used; (ii) dam-
aged by accident or negligence, including failure to follow the proper mainte-
nance, service, and cleaning schedule; or (iii) damaged as a result of (A)
modification or alteration by the purchaser or other party, (B) excessive voltage
or current supplied to or drawn from the interface connections, (C) static elec-
tricity or electro-static discharge, (D) operation under conditions beyond the
specified operating parameters, or (E) repair or service of the product by any-
one other than HII or its authorized representatives.
12 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
This warranty shall extend from the time of shipment for the duration published
by HII for the product at the time of purchase (“Warranty Period”). Any defective
product must be returned (at purchaser’s expense) during the Warranty Period
to HII factory or authorized service center for inspection. No product will be
accepted by HII without a Return Materials Authorization, which may be
obtained by contacting HII. In the event that the product is returned to HII or its
authorized service center within the Warranty Period and HII determines to its
satisfaction that the product is defective due to defects in materials or workman-
ship, HII, at its sole option, will either repair or replace the product without
charge, except for return shipping to HII.
EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW, THE
FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR
WARRANTIES, EITHER EXPRESSED OR IMPLIED, ORAL OR WRITTEN,
INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MER-
CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR NON-
INFRINGEMENT.
HII’S RESPONSIBILITY AND PURCHASER’S EXCLUSIVE REMEDY UNDER
THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THE
DEFECTIVE PRODUCT WITH NEW OR REFURBISHED PARTS. IN NO
EVENT SHALL HII BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSE-
QUENTIAL DAMAGES, AND, IN NO EVENT, SHALL ANY LIABILITY OF HII
ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER
(WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CON-
TRACT, WARRANTY, TORT, OR OTHERWISE) EXCEED THE ACTUAL
AMOUNT PAID TO HII FOR THE PRODUCT. THESE LIMITATIONS ON LIA-
BILITY SHALL REMAIN IN FULL FORCE AND EFFECT EVEN WHEN HII MAY
HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES, LOSSES,
OR DAMAGES. SOME STATES, PROVINCES, OR COUNTRIES DO NOT
ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSE-
QUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY
NOT APPLY TO YOU.
All provisions of this Limited Warranty are separate and severable, which
means that if any provision is held invalid and unenforceable, such determina-
tion shall not affect the validity of enforceability of the other provisions hereof.
Use of any peripherals not provided by the manufacturer may result in damage
not covered by this warranty. This includes but is not limited to: cables, power
supplies, cradles, and docking stations. HII extends these warranties only to the
first end-users of the products. These warranties are non-transferable.
The duration of the limited warranty for the Voyager 1250gAP scanner is five (5)
years.
12 - 2
Download from Www.Somanuals.com. All Manuals Search And Download.
A
Reference Charts
Symbology Charts
Note: “m” represents the AIM modifier character. Refer to International
Technical Specification, Symbology Identifiers, for AIM modifier character
details.
Prefix/Suffix entries for specific symbologies override the universal (All
Symbologies, 99) entry.
page 5-1 for information about using Code ID and AIM ID.
Linear Symbologies
AIM
Honeywell
Hex
Possible
modifiers
(m)
Symbology
ID
ID
All Symbologies
Codabar
99
61
68
6A
3C
]Fm
]H3
]Cm
]X0
0-1
a
h
j
Code 11
Code 128
0, 1, 2, 4
Code 32 Pharmaceutical
(PARAF)
<
Code 39 (supports Full ASCII
mode)
]Am
]L2
0, 1, 3, 4, 5, 7
b
T
i
62
54
69
TCIF Linked Code 39
(TLC39)
Code 93 and 93i
]Gm
0-9, A-Z,
a-m
EAN
]Em
0, 1, 3, 4
d
d
64
64
EAN-13 (including Bookland ]E0
EAN)
EAN-13 with Add-On
]E3
]E3
d
d
64
64
EAN-13 with Extended
Coupon Code
EAN-8
]E4
]E3
D
D
44
44
EAN-8 with Add-On
A - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
AIM
Honeywell
Hex
Possible
modifiers
(m)
Symbology
ID
ID
GS1
GS1 DataBar
]em
]em
]em
]C1
0
y
{
}
I
79
7B
7D
49
GS1 DataBar Limited
GS1 DataBar Expanded
GS1-128
2 of 5
China Post (Hong Kong 2 of ]X0
5)
Q
51
Interleaved 2 of 5
Matrix 2 of 5
]Im
0, 1, 3
e
m
Y
f
65
6D
59
66
66
67
74
]X0
]X0
]Rm
]S0
]Mm
]Bm
NEC 2 of 5
Straight 2 of 5 IATA
Straight 2 of 5 Industrial
0, 1, 3
0, 1
f
MSI
g
t
Telepen
UPC
0, 1, 2, 3, 8,
9, A, B, C
UPC-A
]E0
]E3
]E3
c
c
c
63
63
63
UPC-A with Add-On
UPC-A with Extended
Coupon Code
UPC-E
]E0
]E3
]X0
E
E
E
45
45
45
UPC-E with Add-On
UPC-E1
Add Honeywell Code ID
Add AIM Code ID
Add Backslash
5C80
5C81
5C5C
35
Batch mode quantity
5
A - 2
Download from Www.Somanuals.com. All Manuals Search And Download.
Postal Symbologies
AIM
Honeywell
Hex
Possible
modifiers
(m)
Symbology
ID
ID
All Symbologies
99
51
China Post
]X0
Q
ASCII Conversion Chart (Code Page 1252)
In keyboard applications, ASCII Control Characters can be represented in 3 dif-
ferent ways, as shown below. The CTRL+X function is OS and application
dependent. The following table lists some commonly used Microsoft functional-
ity. This table applies to U.S. style keyboards. Certain characters may differ
depending on your Country Code/PC regional settings.
Non-printable
Keyboard Control + ASCII (CTRL+X) Mode
ASCII control characters
Windows Mode Control + X Mode
On (KBDCAS2)
Control + X Mode Off
(KBDCAS0)
CTRL + X
function
DEC HEX
Char
CTRL + X
0
00
01
02
03
04
05
06
07
08
09
0A
0B
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
Reserved
NP Enter
Caps Lock
ALT Make
ALT Break
CTRL Make
CTRL Break
Enter / Ret
(Apple Make)
Tab
CTRL+ @
CTRL+ A
CTRL+ B
CTRL+ C
CTRL+ D
CTRL+ E
CTRL+ F
CTRL+ G
CTRL+ H
CTRL+ I
1
Select all
Bold
2
3
Copy
4
Bookmark
Center
Find
5
6
7
8
History
Italic
9
HT
10
11
LF
(Apple Break)
Tab
CTRL+ J
CTRL+ K
Justify
hyperlink
VT
list,
left align
12
0C
FF
Delete
CTRL+ L
13
14
15
16
0D
0E
0F
10
CR
SO
SI
Enter / Ret
Insert
ESC
CTRL+ M
CTRL+ N
CTRL+ O
CTRL+ P
New
Open
Print
DLE
F11
A - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Non-printable
Keyboard Control + ASCII (CTRL+X) Mode
ASCII control characters
Windows Mode Control + X Mode
On (KBDCAS2)
Control + X Mode Off
(KBDCAS0)
CTRL + X
function
DEC HEX
Char
CTRL + X
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
127
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
7F
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
Home
PrtScn
Backspace
Back Tab
F12
CTRL+ Q
CTRL+ R
CTRL+ S
CTRL+ T
CTRL+ U
CTRL+ V
CTRL+ W
CTRL+ X
CTRL+ Y
CTRL+ Z
CTRL+ [
CTRL+ \
CTRL+ ]
CTRL+ ^
CTRL+ -
Quit
Save
F1
Paste
F2
F3
F4
SUB
ESC
FS
F5
F6
F7
GS
F8
RS
F9
US
F10
NP Enter
⌂
Lower ASCII Reference Table
Note: Windows Code page 1252 and lower ASCII use the same characters.
Printable Characters
DEC HEX Character
DEC HEX Character
DEC HEX Character
32
33
34
35
36
37
38
39
40
41
42
20
21
22
23
24
25
26
27
28
29
2A
<SPACE>
!
"
#
$
%
&
'
64
65
66
67
68
69
70
71
72
73
74
40
41
42
43
44
45
46
47
48
49
4A
@
A
B
C
D
E
F
G
H
I
96
97
98
99
100 64
101 65
102 66
103 67
104 68
105 69
106 6A
60
61
62
63
`
a
b
c
d
e
f
g
h
i
(
)
*
J
j
A - 4
Download from Www.Somanuals.com. All Manuals Search And Download.
Printable Characters (Continued)
DEC HEX Character
DEC HEX Character
DEC HEX Character
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
+
,
-
.
/
0
1
2
3
4
5
6
7
8
9
:
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
K
L
107 6B
108 6C
109 6D
110 6E
111 6F
112 70
113 71
114 72
115 73
116 74
117 75
118 76
119 77
120 78
121 79
122 7A
123 7B
124 7C
125 7D
126 7E
127 7F
k
l
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
[
m
n
o
p
q
r
s
t
u
v
w
x
y
z
{
|
}
~
⌂
;
<
=
>
?
\
]
^
_
Extended ASCII Characters
PS2 Scan
Code
DEC HEX CP 1252
ASCII
Alternate Extended
128 80
129 81
130 82
131 83
€
Ç
ü
é
â
0x48
0x50
0x4B
0x4D
up arrow ↑
down arrow ↓
right arrow →
left arrow ←
Insert
Delete
‚
ƒ
132 84
133 85
134 86
135 87
136 88
137 89
138 8A
139 8B
140 8C
„
…
†
‡
ˆ
‰
Š
‹
ä
à
å
ç
ê
ë
è
ï
0x52
0x53
0x47
0x4F
0x49
0x51
0x38
0x1D
n/a
Home
End
Page Up
Page Down
Right ALT
Right CTRL
Reserved
Œ
î
A - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Extended ASCII Characters (Continued)
PS2 Scan
Code
DEC HEX CP 1252
ASCII
Alternate Extended
141 8D
ì
Reserved
n/a
142 8E
143 8F
144 90
145 91
146 92
147 93
148 94
149 95
150 96
151 97
152 98
153 99
154 9A
155 9B
156 9C
157 9D
158 9E
159 9F
160 A0
161 A1
162 A2
163 A3
164 A4
165 A5
166 A6
167 A7
168 A8
169 A9
170 AA
171 AB
172 AC
173 AD
174 AE
175 AF
176 B0
177 B1
178 B2
179 B3
Ž
Ä
Å
É
æ
Æ
ô
ö
ò
û
ù
Numeric Keypad Enter
Numeric Keypad /
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
Numeric Keypad +
Numeric Keypad -
Numeric Keypad *
Caps Lock
Num Lock
Left Alt
Left Ctrl
Left Shift
Right Shift
Print Screen
Tab
0x1C
0x35
0x3B
0x3C
0x3D
0x3E
0x3F
0x40
0x41
0x42
0x43
0x44
0x57
0x58
0x4E
0x4A
0x37
0x3A
0x45
0x38
0x1D
0x2A
0x36
n/a
‘
’
“
”
•
–
—
˜
™
š
›
ÿ
Ö
Ü
¢
£
¥
₧
ƒ
á
í
ó
ú
ñ
Ñ
ª
º
¿
⌐
¬
½
¼
¡
œ
ž
Ÿ
¡
¢
£
¤
¥
¦
§
¨
©
ª
0x0F
0x8F
0x1C
0x01
0x36
0xB6
0x1D
0x9D
Shift Tab
Enter
Esc
Alt Make
Alt Break
Control Make
Control Break
Alt Sequence with 1 Character 0x36
Ctrl Sequence with 1 Character 0x1D
«
¬
®
¯
°
±
²
«
»
░
▒
▓
│
³
A - 6
Download from Www.Somanuals.com. All Manuals Search And Download.
Extended ASCII Characters (Continued)
PS2 Scan
Code
DEC HEX CP 1252
ASCII
Alternate Extended
180 B4
181 B5
182 B6
183 B7
184 B8
185 B9
186 BA
187 BB
188 BC
189 BD
190 BE
191 BF
192 C0
193 C1
194 C2
195 C3
196 C4
197 C5
198 C6
199 C7
200 C8
201 C9
202 CA
203 CB
204 CC
205 CD
206 CE
207 CF
208 D0
209 D1
210 D2
211 D3
212 D4
213 D5
214 D6
215 D7
216 D8
217 D9
218 DA
´
µ
¶
·
¸
¹
º
»
¼
½
¾
¿
À
Á
Â
Ã
Ä
Å
Æ
Ç
È
É
Ê
Ë
Ì
┤
╡
╢
╖
╕
╣
║
╗
╝
╜
╛
┐
└
┴
┬
├
─
í
╞
╟
╚
╔
╩
╦
╠
═
╬
╧
╨
╤
╥
╙
╘
╒
╓
╫
╪
┘
┌
Í
Î
Ï
Ð
Ñ
Ò
Ó
Ô
Õ
Ö
×
Ø
Ù
Ú
A - 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Extended ASCII Characters (Continued)
PS2 Scan
Code
DEC HEX CP 1252
ASCII
Alternate Extended
219 DB
220 DC
221 DD
222 DE
223 DF
224 E0
225 E1
226 E2
227 E3
228 E4
229 E5
230 E6
231 E7
232 E8
233 E9
234 EA
235 EB
236 EC
237 ED
238 EE
239 EF
240 F0
241 F1
242 F2
243 F3
244 F4
245 F5
246 F6
247 F7
248 F8
249 F9
250 FA
251 FB
252 FC
253 FD
254 FE
255 FF
Û
Ü
Ý
Þ
ß
à
á
â
ã
ä
å
æ
ç
è
é
ê
ë
ì
█
▄
▌
▐
▀
α
ß
Γ
π
Σ
σ
µ
τ
Φ
Θ
Ω
δ
∞
φ
ε
∩
≡
±
≥
≤
⌠
⌡
÷
≈
°
í
î
ï
ð
ñ
ò
ó
ô
õ
ö
÷
ø
ù
ú
û
ü
ý
þ
ÿ
·
·
√
ⁿ
²
■
A - 8
Download from Www.Somanuals.com. All Manuals Search And Download.
ISO 2022/ISO 646 Character Replacements
Code pages define the mapping of character codes to characters. If the data
received does not display with the proper characters, it may be because the bar
code being scanned was created using a code page that is different from the
one the host program is expecting. If this is the case, select the code page with
which the bar codes were created. The data characters should then appear
properly.
Code Page Selection
Method/Country
Standard
Keyboard
Country
Honeywell
Code Page
Option
United States
(standard ASCII)
ISO/IEC 646‐IRV
n/a
1
Automatic National
Character
Replacement
ISO/IEC 2022
n/a
2 (default)
Binary Code page
n/a
n/a
3
Default “Automatic National Character replacement” will select the below
Honeywell Code Page options for Code128, Code 39 and Code 93.
United States
Canada
ISO/IEC 646‐06
ISO /IEC 646‐121
ISO /IEC 646‐122
ISO/IEC 646‐14
ISO/IEC 646‐57
ISO /IEC 646‐04
ISO /IEC 646‐69
ISO/IEC646‐21
ISO /IEC 646‐CH
0
54
18
28
92
7
1
95
96
98
99
87
83
84
86
Canada
Japan
China
Great Britain (UK)
France
3
Germany
Switzerland
4
6
Sweden / Finland
(extended Annex C)
ISO/IEC 646‐11
2
82
97
Ireland
ISO /IEC 646‐207
73
A - 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Code Page Selection
Method/Country
Standard
Keyboard
Country
Honeywell
Code Page
Option
Danmark
Norway
Italy
ISO/IEC 646‐08
ISO/IEC 646‐60
ISO/IEC 646‐15
ISO/IEC 646‐16
ISO/IEC 646‐17
ISO/IEC 646‐85
8
9
88
94
85
92
90
91
5
Portugal
Spain
13
10
51
Spain
A - 10
Download from Www.Somanuals.com. All Manuals Search And Download.
35 36 64 91 92 93 94 96 123 124 125 126
Dec
Hex
23 24 40 5B 5C 5D 5E 60
7B
{
7C
|
ù
ù
|
7D
}
7E
~
û
û
⎯
US
0
54
18
28
92
7
1
#
#
#
#
#
£
£
#
ù
#
#
#
£
£
#
#
#
$
$
$
$
¥
$
$
$
$
¤
$
$
$
$
$
$
$
@
à
[
â
â
[
\
ç
]
ê
ê
]
^
î
`
ô
ô
`
CA
é
é
{
è
è
}
95
96
98
99
87
83
84
86
82
88
94
97
85
92
90
91
à
ç
É
^
^
^
^
^
î
CA
JP
@
@
@
à
¥
\
[
]
`
{
|
}
CN
GB
FR
⎯
[
\
]
`
{
|
}
˜
¨
°
ç
§
Ü
ê
Å
Å
Å
Ú
é
Õ
¿
Ç
µ
`
é
ä
ä
ä
æ
æ
é
à
ã
°
ù
ö
ö
ö
ø
ø
í
è
ü
ü
å
å
å
ú
è
õ
ç
3
§
Ä
é
Ä
Æ
Æ
É
°
Ö
ç
ß
û
ü
˜
¨
DE
CH
SE/FI
DK
NO
IE
4
à
ô
é
`
6
É
Ö
Ø
Ø
Í
Ü
^
^
Á
^
^
^
¿
2
@
@
Ó
§
8
`
9
ó
ù
`
á
ì
73
5
ç
ò
ç
IT
§
Ã
¡
Ç
Ñ
Ñ
°
PT
13
10
51
§
`
ñ
ñ
˜
¨
ES
∙
¡
`
´
ç
ES
ISO / IEC 646 National Character Replacements
A - 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Unicode Key Maps
6E
70 71 72 73
74 75 76 77
78 79 7A 7B 7C 7D 7E
01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0F
10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D
1E 1F 20 21 22 23 24 25 26 27 28 29 2B
4B 50 55
4C 51 56
5A 5F 64 69
5B 60 65
6A
5C 61 66
2C 2E 2F 30 31 32 33 34 35 36 37
39
5D 62 67
6C
4F 54 59
63 68
3D
3A 3B 3C
3E 3F 38 40
104 Key U.S. Style Keyboard
6E
70 71 72 73
74 75 76 77
78 79 7A 7B 7C 7D 7E
01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0F
10 11 12 13 14 15 16 17 18 19 1A 1B 1C
1E 1F 20 21 22 23 24 25 26 27 28 29 2A
4B 50 55
4C 51 56
5A 5F 64 69
5B 60 65
2B
6A
5C 61 66
2C 2D 2E 2F 30 31 32 33 34 35 36 37
39
5D 62 67
6C
4F 54 59
63 68
3D
3A 3B 3C
3E 3F 38 40
105 Key European Style Keyboard
A - 12
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Sample Symbols
Matrix 2 of 5
GS1 DataBar
6543210
(01)00123456789012
Download from Www.Somanuals.com. All Manuals Search And Download.
Honeywell Scanning & Mobility
9680 Old Bailes Road
Fort Mill, SC 29707
VG1250gAP-UG Rev A
8/13
Download from Www.Somanuals.com. All Manuals Search And Download.
|