Hearth and Home Technologies Indoor Fireplace 36EBU User Manual |
7205240100REV00
Installation Guide for the
36-EBU and 42-EBU Electric Fireplace
LISTINGS AND CODE APPROVALS
The EBU series fireplaces have been tested in accordance with the UL 2021 and CSA C22.2 No. 46 standards for fixed
and location-dedicated electric room heaters.
MODEL SPECIFICATIONS
Model
Number
Rated Power
Watts
Remote
Control
Wall
Thermostat
Mesh
Screen
AMPS
120Volt
AMPS
208Volt
AMPS
240Volt
Description
Voltage Volts
36-EBU
42-EBU
36” Standard
42” Standard
120/208/240
120/208/240
1650/2340/3025
1650/2340/3025
Included
Included
Included
Included
Included
Included
13.75
13.75
11.25
11.25
12.6
12.6
NOTE: Power ratings shown include the light bulbs and motor (275 watts)
STEP-BY-STEP INSTALLATION (Note: Please read all instructions before installing)
1. Rough in framing opening following the recommended dimensions (Section A: Framing).
2. Allow 8” of service cable for connecting to the junction box on the fireplace. Remove the outer jacket and strip
the individual conductors ½” from the end.
3. Loosen the screw securing junction box cover and remove the cover.
4. Remove knockouts if necessary or use the provided cable clamp.
5. Place unit in position in the opening, level with shims if necessary and attach unit to frame using nailing flanges
provided.
6. Unit is factory wired for 208/240 volt power supply. If 120 volt operation is required, slide the switch and
reconfigure the wiring as covered in section C wiring. Wires L1, L2, N & G are attached to the rear of the
junction box cable clamp for easy access.
7. Wire a dedicated, properly fused circuit with a 20amp rating for the appropriate voltage (120, 208/240).
8. Make wall mounted thermostat connections as outlined in Section C: Wiring.
9. Place all connectors inside the unit and replace the junction box cover, ensuring that the cable clamp grips only
the jacket of service or thermostat.
266-950 5/03
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION C: WIRING
NOTE: The unit is factory configured for 208/240 volt operation
NOTE: All wiring must be completed prior to installing the unit.
NOTE: Ensure that the power conversion switch is in the proper position for the required supply voltage prior to
connecting the unit to power supply.
240 VOLT INSTALLATIONS
1. Locate the switch on the top corner of the unit.
2. Ensure that the switch is in the 230 volt position.
3. Loosen the screw securing the junction box cover and remove the cover.
4. Remove the knockouts (if necessary) or use the provided cable clamp.
5. Pull out the four wires marked L1, L2, N, and G.
6. Connect the black L1 wire from the unit to the L1 from the power supply. Connect the red L2 wire from the unit
to the L2 from the power supply. Connect the white N wire from the unit to the neutral from the power supply.
Connect the green ground wire from the unit to the ground from the power supply.
7. When the unit has been configured for the appropriate power supply voltage, ensure that all connections are
tight. Insert all the wiring into the unit and secure with a cable clamp.
TO RECONFIGURE FROM 240 VOLT TO 120 VOLT
1. Locate the switch on the top corner of the unit.
2. Flip the switch from 230 volt to 115 volt configuration.
3. Loosen the screw securing the junction box cover and remove the cover.
4. Remove the knockouts (if necessary) or use the provided cable clamp.
5. Pull out the four wires marked L1, L2, N, and G.
6. Connect the black L1 wire from the unit to the L1 from the power supply. Connect the red L2 and white N wires
to the neutral from the power supply. Connect the green ground wire from the unit to the ground from the power
supply.
7. When the unit has been configured for the appropriate power supply voltage, ensure that all connections are
tight. Insert all the wiring into the unit and secure with a cable clamp.
TOP OF FIREPLACE
230 VOLT/115 VOLT SWITCH
Download from Www.Somanuals.com. All Manuals Search And Download.
WALL MOUNTED THERMOSTAT WIRING
NOTE: Wiring of the thermostat must be completed prior to installing the unit.
NOTE: The following installation instructions are for a single pole thermostat included with the unit.
120 / 240VOLT INSTALLATIONS
The wall mounted thermostat is connected to the fireplace by running a 2 conductor wire with a ground from the junction
box on the back of the unit to the thermostat.
1. Locate the switch on the top corner of the unit and ensure that the power conversion switch is in the proper
position for the required supply voltage.
2. Loosen the screw securing the junction box and remove the cover. Pull out the wire nut that contains wires
marked 1 & 2.
3. Remove the wire nut and separate the wires marked 1 & 2.
4. Connect one of the wires from the thermostat to the wire marked 1 and the other wire to the wire marked 2.
5. Connect the ground wire from the thermostat to the ground wire grouping from the power supply.
6. Ensure that all connections are tight. Insert all the wiring into the unit and secure with a cable clamp.
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING DIAGRAM WITH REMOTE CONTROL
Download from Www.Somanuals.com. All Manuals Search And Download.
Service Parts
36-EBU, 42-EBU
(NG, LP) Exploded Part Diagram
(GN, PL) Vue éclatée des pièces
Beginning Manufacturing Date: 6-01
Ending Manufacturing Date: ______
12
11
9
2
5
6
1
3
4
8
7
10
Download from Www.Somanuals.com. All Manuals Search And Download.
36-EBU, 42-EBU Electric Fireplace Service Parts List
36-EBU
None
42-EBU
None
MODEL >
MOD. LEVEL >
ITEM
REPLACEMENT PART
PART NUMBER
1
1
2
3
4
5
6
7
8
9
LOG SET
0438200300RP
0438440100RP
5900160100RP
2800070400RP
2800070500RP
8800240103RP
2500130100RP
6900360100RP
6900190500RP
5300110300RP
3000200300RP
2200460100RP
2300200200RP
2300200100RP
TS901W
0438200300RP
0438440100RP
5900160200RP
2800070400RP
2800070500RP
8800240203RP
2500130100RP
6900360100RP
6900190500RP
5300110300RP
3000200300RP
2200460100RP
2300200200RP
2300200100RP
TS901W
30" LOG SET
MIRROR ASSEMBLY
POWER ON/OFF SWITCH
AUXILARY CONTROL SWITCH
MESH CURTAIN
LOWER LIGHT HARNESS
AC MOTOR
REFLECTOR ROTISSERIE
BLOWER ASSEMBLY
10 REMOTE CONTROL ASSEMBLY
11 ELEMENT
12 TEMPERATURE LIMITING SWITCH
HIGH LIMIT CUTOUT
WALL MOUNTED THERMOSTAT
REMOTE CONTROL TRANSMITTER
CIRCUIT BOARD
3000200600RP
3000200700RP
0438290100RP
8800250100RP
2500180100RP
3000200600RP
3000200700RP
0438290100RP
8800250200RP
2500180100RP
MIRROR CHANNEL
MESH SCREEN ROD
VOLTAGE SELECTOR SWITCH WITH WIRES
Use Sylvania light bulbs item #SL13460 that can be ordered via the website www.lite-house.com or by call 1-800-838-
0977. You can also buy replacement bulbs at most hardware stores and home centers: clear chandelier Candelabra
bulbs with E-12 (small) socket base, 60 watts rating. Ex. GE 60BC or Phillips 60CTC.
Download from Www.Somanuals.com. All Manuals Search And Download.
|