II. OPERATING INSTRUCTIONS  
20  
1.  
2.  
3.  
4.  
5.  
Start Up  
Shut Down  
Working with the Rotisserie  
Cooking Times  
SpittingChickens  
A. Using Angle Spits  
B. Using Regular Spits  
Loading and Unloading Spits  
Checking Chickens for Doneness  
Cooking other Products  
Cleaning  
20  
20  
21  
22  
23  
23  
28  
33  
34  
34  
34  
36  
6.  
7.  
8.  
9.  
10.  
Maintenance  
III. CRITICAL CONTROL STEPS FOR PREPARATION AND COOKING  
OF BARBECUE CHICKENS  
37  
38  
IV. WARRANTY  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 3 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
I. INITIAL STEPS  
1. Placing the Machine  
Barbecue products are often bought on impulse. The continuous style rotisserie models have been  
designed for maximum viewing by both the customers as well as the operator. The unit usually has  
a front glass surface and should be placed where it will get the best and most exposure. Wherever  
the unit is placed, remember that the operator will need continual access through the glass doors.  
WARNING: THESE MACHINES ARE OVENS AND SHOULD NEVER BE PLACED  
WITHIN PUBLIC ACCESS.  
FOLLOW MINIMUM CLEARANCE REQUIREMENTS FOR ALL UNITS  
AS PER SPECIFICATION GUIDES.  
2. Assembling the Machine  
The N/45G come fully assembled except for the glass, spits, skewers, baskets and thumb screws,  
which are individually packed. Check all parts and accessories with your packing list. Remove all  
tape on glass and vinyl coating on stainless steel before operating the machine.  
3. Electrical Connection  
The electrical connections on the N/45G is less than 15 amps, 120V, so just connect the plug sup-  
plied with the unit into a regular outlet.  
4. Gas Connection  
The N/45G gas connection must be performed by a licensed gas fitter. All units are supplied with a  
main shut off valve (gas cock) and a pressure regulator.  
5. Venting  
The N/45G is fully opened along the top for air evacuation and must be placed under a canopy type  
hood.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 4 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
II Installation Instructions  
1.1  
General Information  
The Operating Instructions are to be given to the operator of the rotisserie. All unit  
operators are to be familiar with the functions of the rotisserie.  
The Operating Instructions should be kept in a location close to the rotisserie. It should be  
easily recognizeable and easily accessible.  
These rotisseries can be used with both natural and LPG gases. The rotisseries can be  
converted or adjusted to any type of the locally distributed natural and LPG gases.  
It is recommended that a repair and maintenance contract be signed with the  
manufacturer's agent, distributor, or service agency.  
1.2  
Description of the Data Plate  
HICKORY INDUSTRIES, INC.  
COMMERCIAL COOKING APPLIANCES  
NORTH BERGEN, NJ  
07047  
MODEL N/45  
SERIAL NO.  
MOTOR: 110 - 115 VOLTS 60 CYCLE AC CURRENT  
1/3 HP SINGLE PHASE 1725 RPM  
BURNERS  
3
*4 burners for 45 Plus  
LISTED  
60,000  
BTU/H  
GAS INPUT PER BURNER  
MANIFOLD  
PRESSURE  
5.5"  
69D6  
TYPE OF GAS  
NAT  
MFG. DATE  
MINIMUM INSTALLATION CLEARANCE  
SIDE: 6 INCHES  
BACK: 6 INCHES  
MAXIMUM LAMP WATTAGE: 150 WATTS  
FOR INSTALLATION ON A COMBUSTIBLE FLOOR  
Gas-fired Food Service Equipment Classified by  
Underwriters Laboratories Inc. In accordance with American  
National Standards Institute ANSI Z 83.11b-1991, Gas Food  
Service Equipment-Ranges and Unit Boilers  
WARNING!  
This unit must be installed and connected in accordance to the latest regulations  
and can only be operated in conjunction with forced ventilation or exhaust hood.  
This unit has been designed for professional use only  
and may only be installed or repaired by licensed service agencies!  
Before installing or using this equipment, read these instructions!  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 5 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
1.3 Machine Drawings and Dimensions  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 6 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
1.4  
Conversion and Adjustment Instructions  
Before converting or adjusting the machine, it is imperative that the manual gas cock be  
turned to the "off" position. The electrical power to the machines should also be turned off.  
When converting from one type of gas to another, the main gas orifice (or injector), the  
pilot burner orifice (or injector), and the primary air adjustment must be changed according  
to the table on page 9. In addition, the spring in the pressure regulator must be changed so  
that it can operate at higher pressures.  
1.6  
Verification for use with Natural Gas  
The highest flame setting ("on" position on the manifold gas valves) for each of the pipe  
burners can be confirmed by using the volumetric method in conjunction with the main gas  
meter. From the "pilot" position, turn the Gas Control Lever clock-wise, towards "on", until  
the lever goes no further.  
To carry out this verification procedure, it is necessary to obtain the heating value (BTU/ft3)  
of the local gas from the local gas company.  
If the measured gas volume does not correspond to the values in the following table, the  
first item which should be checked is the incoming (connected) gas pressure. If the  
pressure is correct, it must be verified that the proper size gas orifices are in place.  
Gas Line Input Connection  
Thermocouple Connection  
Flow Index Button  
Gas Control Lever  
(in Pilot position)  
Pilot Gas Connection  
Gas Line Output  
(connection to venturi)  
Manifold Valve  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 7 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
1.7  
Natural Gas Flow Table  
Gas Flow  
Heating Value in  
Gas  
per Burner (40,000 BTU)  
inft3/hr  
BTU/ft³  
High Flame Setting  
Natural  
Propane  
Butane  
1040  
2500  
2500  
57.75  
24.00  
24.00  
1.7.1 Volumetric Method to Verify the High Flame Setting, Mathematical  
WARNING! No other gas equipment can be in operation during this procedure.  
Calculation of flow rate E in ft3/hour  
E =  
FP  
Hi  
E = Flow rate in ft3/minute  
FP = High Flame Power setting in BTU/hr  
Hi= Heating value in BTU/ft3  
Thus, for natural gas:  
E = 60,000  
1040  
BTU/hr  
BTU/ft3  
=
57.75 ft3/hr  
=
0.96 ft3/min.  
E = 0.96 ft3/min.  
Calculation of the natural gas needed in 1 hour by a 45WDG (3 burners) at full power:  
57.75 * 3 = 173.25 ft3/hr 2.89 ft3/min.  
=
The time and the flow measurements should be taken at the gas (flow) meter with a  
chronometer (stop watch).  
To run the test, open the manual gas cock valve, start up the unit according to the start-up  
instructions on page 24 and set the manifold valves to the high flame setting ("on" position).  
Allow the unit to pre-heat (burn) for 10 to 15 minutes. Verify that the flow rate is calibrated  
to the appropriate flow rate indicated in the table.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 8 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
1.8  
Orifice Diameters, Primary Air Intake Settings, and Pressure Regulators  
Pilot Orifice  
Gas / Pressure  
inches W.C.  
Main Orifice  
Ø in drill size  
Primary Air Intake  
in inches  
Orifice Marking  
3/16 "  
1/8 "  
1/8 "  
Natural / 5.5"  
5 holes @#55  
3211  
Propane / 11"  
Butane / 11"  
2 holes @#55  
2 holes@#55  
3221  
3221  
3/16"  
3/16"  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 9 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
1.9  
Changing Gas Orifices  
1.9.1 Changing the Main Gas Orifice  
1.  
2.  
The venturi tubes and manifold valves are on the same side as the spit handles.  
On each venturi, loosen the lock nuts (7/8" wrench) and then move the nut  
and the air intake cap all the way to the top of the nipple.  
With a 3/4" wrench, loosen the nipple so that it can be removed from the  
venturi.  
3.  
4.  
With the nipple/orifice assembly off, separate the main orifice from the  
nipple with a pipe wrench or a pair of pliers.  
Nipple  
Air Intake Cap  
Lock Nut  
Air Intake Adjustment  
Main Orifice  
Venturi Tube  
Venturi Assembly  
Re-assemble all of the components with the new main orifice. Make sure that the proper air intake  
adjustment is made for the new type of gas (according to the tables on page 9). The flames should be  
blue in color, must be stable, and must not "lift off" the burner.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 10 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
1.9.2 Changing the Pilot Orifice  
1.  
To reach the pilot burner, open the sliding glass doors, the sliding or hinged metal  
door, remove all spits, as well as all ceramics.  
2.  
3.  
Before removing, mark the position of the support bracket on the side wall.  
Loosen the pilot burner assembly by removing the two screws which attach each  
pilot burner (support bracket) to the main body of the machine.  
4.  
With the assembly loose, carefully pull the entire assembly forward about 6".  
Pilot Orifice  
Pilot Flame  
Openings  
Thermocouple  
Pilot Burner Assembly  
5.  
6.  
Loosen the gas line connection to the pilot orifice with a 7/16" wrench. Carefully  
separate the gas line from the pilot burner. From the pilot burner, carefully  
remove the pilot orifice using a 1/2" wrench.  
Reassemble the pilot burner using the new pilot orifice and place the support bracket  
in its original position. The following pilot orifices are to be used with each type of  
gas.  
Pilot Orifice  
LPG  
Marking  
3221* Verbally confirm model 45 when ordering.  
Natural Gas  
3211*Verbally confirm model 45 when ordering.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 11 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
1.10 Checking the Connected Gas Pressure (Nominal Pressure)  
Close the gas cock where the gas line is connected to the machine and attach a manometer  
to the tap (allen screw) on the gas cock. With the manometer connected, open the gas  
cock, ignite all burners, and set the manifold valves to "on" or maximum setting. Along with  
all other gas appliances at the location in operation, measure the gas pressure.  
This nominal pressure should be 5.5" W.C. for natural gas and 11" W.C. for LPG.  
If the measured pressure falls below the range mentioned above, the installer should try to  
find the cause of the problem and resolve it. A typical source of this problem is that the gas  
line (pipe) diameter leading up to the unit is too small. If it is not possible to resolve the  
problem, the local gas company or gas supplier should be contacted so that they can resolve  
the problem.  
If the nominal pressure is below 5.5 " W.C. for natural gas or below 11 " W.C. for LPG, the  
unit should not be operated. These should be adjusted to the ideal settings using the pressure  
regulating screw on the pressure regulator.  
If the pressure is too high and can not be adjusted downward, check to see if the proper  
adjusting spring is in place. If this is correct, the regulator membrane may have been  
ruptured by excessive gas pressure and may have to be replaced. Do not operate the  
rotisserie if the gas pressure is too low.  
If the pressure is too low and can not be adjusted upward, also check the regulator. If this is  
correct, verify the pressure coming out of the main gas meter or the diameter of the gas pipe  
feeding gas to the unit. If the gas line is under-sized, the appropriate pressure may not be  
reached. Do not operate the unit if the pressure falls below 5.5" W.C.  
After the pressure has been set, close the gas cock once again, remove the manometer, seal  
the pressure regulator, and then re-open the gas cock.  
WARNING: After an installation, repairs, or maintenance, make sure that there are  
no gas leaks anywhere in the gas lines or system.  
1.11 Maintenance, response to technical problems, reasons for problems and solutions  
Should a technical problem arise for any reason, shut off the machine and call for technical  
service.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 12 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
A routine maintenance should be carried out at least once a year. Contact your local,  
certified service company for maintenance.  
Problem  
Burners do  
not ignite.  
Cause  
No gas flow.  
Solution  
a.  
b.  
a.  
b.  
Make sure that all gas valves are  
open and that gas is reaching unit.  
Remove and control the gas valve  
at the connection (manual) or the  
LPG pressure regulator. Contact  
gas company or distributor.  
Gas container too cold  
especially with butane.  
Water in gas freezes  
in gas regulator.  
Pilot burner  
ignites. Main  
burner initially b.  
ignites, but  
then goes out.  
a.  
Thermocouple tip is not  
enveloped by pilot flame.  
Thermocouple is not  
heated enough by flame or  
it is being heated along the  
entire length too much.  
Primary air intake blocked  
or must be adjusted.  
Thermocouple is loose at  
one of the connections.  
Defective thermocouple.  
Gas pressure too low.  
Wrong orifice size.  
a.  
b.  
Adjust thermocouple position.  
Only the themocouple tip should be  
enveloped by the pilot flame and  
heated. The pilot flame must be  
strong and blue in color.  
Clean or adjust opening according  
to table in page 9.  
Tighten all thermocouple  
connections.  
Replace thermocouple (service co.).  
Contact service or gas company.  
Install correct orifices.  
c.  
d.  
e.  
c.  
d.  
e.  
a.  
b.  
Burners too  
weak.  
a.  
b.  
Burner  
Too much primary air.  
Adjust the primary air intake.  
(contact service company)  
Block off holes on the main burner  
pipe directly below the pilot burner.  
Replace thermocouple (service co.).  
back-fires.  
Pilot flame  
does not stay  
on.  
a.  
b.  
Flames on pipe burners  
disrupting pilot flame.  
Defective thermocouple.  
a.  
b.  
1.12 Testing or checking for safety  
After a conversion, a new installation, or after a repair, it is important that the unit be  
tested to insure that it operates properly. This should include the following:  
Test for gas leaks.  
Check that the unit has enough clearance behind and to the sides.  
Check that enough primary and secondary air is available (strong blue flames).  
Check for potentially flammable objects or potential flammability problems.  
Check the gas distribution systems.  
Check for proper ventilation and exhaust.  
Check for proper room ventilation.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 13 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
When first installing, after repairing, or after cleaning the units, it is important to make  
sure that all components are properly in place.  
a.  
b.  
c.  
There should be a total of 9, evenly spaced ceramic bricks sitting above each main  
pipe burner.  
The ceramics must be sitting directly on the burners. These ceramic  
bricks should also be placed so that they fit between the ceramic support rods.  
The burner pipes should not have any holes (flames) directly below the pilot  
burner assembly. If holes (flames) are present, they will overheat the thermocouple or  
blow out the pilot flame, preventing the main burner from staying lit.  
1.14 Description of the Electrical Connection  
The electrical connections are to be made in accordance to local and national codes.  
All gas machines operate with 120 Volt, single phase, 60 Hz. A NEMA 5-15P plug  
is supplied with the units.  
All pertinent electrical information can be taken from the electrical diagram.  
1.15 Electrical Diagram - All Models  
L
M
L
N
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 14 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
1.16 Parts List for N /4 5WDG  
Item Qty. Description  
Material Length  
Ceramic  
SS  
Size  
Manufacturer  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
113 39  
1
Ceramic Radiants (Single Face)  
Accordian Door (Option)  
Drip Pan45  
120  
121  
122  
131  
2
2
2
2
SS  
Drip Pan Plug  
Brass  
Brass  
Fiber  
SS  
SS  
Alum.  
Alum.  
Drip Pan Receptacle  
Fiber Motor Worm Gear  
Glass Track, Top  
Glass Track, Bottom  
Glass Trolley 45  
Handle 45  
Lamp Par, 120 V  
Motor, 1/3 HP - 120V  
Motor Worm Steel  
Oil Lite Bushing  
409T 1  
409B 1  
410  
2
2
2
2
2
150  
155  
157  
SS  
Brass  
SS  
SS  
SS  
SS  
Nylon  
SS  
SS  
SS  
Iron  
Iron  
Steel  
Steel  
Iron  
Brass  
Steel  
Alum.  
Copper  
Steel  
SS  
158 33  
159  
414  
415  
182  
6
2
3
1
Pillow Block Bearing 5/8"  
Reflector Panel 45WDG Curved  
Reflector Panel 45 WDG Flat  
Shaft 5/8"  
184 22  
Shaft Worm  
420  
421  
414  
227  
229  
231  
233  
234  
232  
162  
163  
164  
138  
175  
152  
214  
110  
111  
2
1
1
3
3
3
3
3
3
3
3
3
3
3
2
3
2
2
Spit Plate, N/45 Exterior  
Spit Plate, N /45 Center  
Top Reflector Single  
Venturi Cap  
Venturi Lock Nut 3/8" ID, 3/4" OD  
Venturi Nipple  
Venturi Threading Tube, Brass  
Venturi Tube  
Main Orifice, Nat. Gas  
Pilot Burner (includes pilot orifice)  
Pilot Gas Line  
Pilot Thermocouple  
Gas Pipe Burner  
Retainer Rod 45 for Ceramics  
Lamp Socket  
Switch, 1-Pole  
Caster w/ brake  
1 - 1/2"  
Ceramic  
Nylon  
Nylon  
Caster w/o brake  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 15 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
1.16 Parts List for N / 45WDG (Contd.)  
Item Qty. Description  
Material Length  
Size  
Manufacturer  
417  
9
Spit Regular Complete (with screws)  
SS  
SS  
SS  
SS  
Nylon  
Nylon  
SS  
SS  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Maxitrol  
Hickory  
179 2/spit Roll Pin 1/8" Stainless  
190  
191  
192  
419  
9
9
9
9
Spit Regular, without collar  
Spit Collar  
Spit Gear  
Spit Handle, 6" Short  
185 4/Spit Skewer Double  
186 2/Spit Skewer Single  
219 6/Acc. Thumb Screw  
408  
407  
165  
7A  
135  
7B  
7C  
SS  
2
2
1
Tempered Glass 30"x33 3/4"  
Glass Frame 45  
Pressure Regulator 3/4"  
Pipe  
Gas Cock Valve  
Pipe  
T-Connector  
Nipple (Adapter 3/4" to 3/8")  
Flexible Pipe  
Manifold Gas Valve  
Nipple  
Venturi Assembly  
Venturi Elbow, 90º  
Pipe  
Tempered Glass  
SS  
Alum.  
3/4"  
3/4"  
3/4"  
3/4"  
3/4"  
1
1
1
3
6
3
3
3
3
3
1
1
1
Steel  
Steel  
Steel  
Steel  
Steel  
SS  
SS  
Steel  
Iron  
3.5"  
6"  
Hickory  
Hickory  
Hickory  
Dormont  
Baso  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
Hickory  
7D  
1.7"  
4.25"  
132  
180  
7E  
226  
228  
7F  
3/8"  
3/8"  
3/8"  
3/8" - 1-1/2"  
1-1/2"  
3/4"  
3/4"  
3/4"  
1.5"  
Iron  
Steel  
Steel  
Steel  
14.5"  
16"  
7G  
7H  
Pipe  
Pipe Cap (threaded)  
The following parts are not shown in the diagrams:  
123  
1
Electrical Grounding Cap  
Electrical Wire  
Connection Cable  
Contact Section 242 (terminal)  
Contact Section 250 (end-piece)  
Hickory  
Janor Wire  
TIP Products  
Buchanan  
Buchanan  
1
1
1
104  
105  
*All components are inventories and sold through Hickory Industries and their distributors and dealers.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 16 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 17 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 18 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 19 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
II. Operating Instructions  
1.0 Start Up  
a.  
b.  
c.  
d.  
Switch the exhaust hood to on.  
Open the gas cock at the rear of the machine.  
Turn the knob on the manifold valve to the "pilot" position.  
While pressing the "flow index" button down, place a match, or other type of  
ignition method, to the pilot burner until it is lit. Keep the knob pressed down  
for at least 40- 60 seconds so that the thermocouple tip warms up and the pilot  
flame remains lit.  
e.  
f.  
Release the knob. The pilot flame should stay on.  
Repeat the procedure for the other burners.  
g.  
Turn the manifold valve knob to the desired setting ("on" must be lined up  
with the "flow index" button for high flame or maximum heat). The pipe  
burner should now light up.  
h.  
i.  
Allow the unit to pre-heat for about 15 minutes.  
When ready to load the spits with product, turn the light and the motor  
switches to the on position.  
2.0 Shut Down  
a.  
Turn the manifold valve knobs to the "off" position if all flames are to be  
shut off. If the pilot light is to remain lit and only the pipe burners are to be  
shut off, turn the manifold valve knobs to the "pilot" position. Note that to  
turn the knobs to the "off" position, one must pull out on the locking  
mechanism on the knobs and then turn the valve to the off position.  
b.  
c.  
After all of the loaded spits have been removed, turn the motor and lights off.  
Close the gas cock at the rear of the machine if the pilot flames are also shut  
off.  
d.  
Turn off the exhaust hood.  
WARNING! Do not clean the machine or glass while these are hot! Everything  
should be cooled down before cleaning.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 20 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
3.0 Working with the Rotisserie  
A. Cooking Temperature  
The desired temperature in the rotisserie can only be set with the manifold valve knob. Setting "on"  
is for the high flame setting and represents about 540°F. The grilling temperature can be reduced by  
turning the knob counter clock-wise (CCW), towards the "pilot" position.  
Flow Index Button  
Reduced Flame Setting  
"Off" Locking Mechanism  
High Flame Setting  
Gas Control Lever  
Manifold Valve Knob in "Pilot" Position  
As a general rule, the higher the grilling temperature, the shorter the cooking time. However, when  
working with the Old Hickory rotisserie, one must consider that the temperatures will vary from top  
to bottom. The top of the unit will have higher temperatures due to the natural convection. The  
cooking temperatures indicated above refer to the top section of the machine. For this reason, the  
product on the top spits will be cooked faster than the product on the lower spits.  
This factor allows for continuous cooking. As the top spits are ready, they should be removed. The  
spits directly below should then be moved up one spit position, thus freeing a spit position at the  
bottom of the unit. This bottom position can then be loaded with fresh, raw product. By loading  
raw product to the bottom, there is no danger of cross contamination.  
WARNING: The only way to be sure that the product is completely cooked is by  
taking the internal temperatures. For example, with poultry, the  
internal temperature must be at least 185°F at the inner side of the thigh.  
For example, when preparing chicken.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 21 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
4.0 Cooking Times  
Product  
Cooking Time  
45 - 60 minutes  
120 - 170 minutes  
20 - 45 minutes  
45 minutes (to 104°F)  
45 minutes (to 135 °F)  
20 - 30 minutes  
120 minutes  
Temperature  
Chicken  
Turkey  
"ON"  
1/2 power  
increase to "ON" for last 20 min.  
"ON"  
Ribs  
Beef Roast  
Pork Loin  
Salmon  
"ON"  
"ON"  
"ON"  
Duck  
1/2 power - 105 minutes  
"ON" - 15 minutes  
"ON"  
Vegetables  
(Zuccini)  
Potatoes  
20 minutes  
40 minutes  
"ON"  
5.0 Spitting Chickens  
The most important part in getting started with a rotisserie is knowing how to properly spit the product.  
This is quite easy, but it must be learned! As an operator, you will become an expert in spitting chick-  
ens within half an hour! There are two types of commomly used spits: the angle spit and the regular  
spit. The following pages describe and show how spitting is done with both these types of spits.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 22 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.0 Spitting Chickens  
A. Using Angle Spits  
Hickory Industries, Inc.  
Figure 1. Chickens Ties  
When using a “V” or angle spit, it is very important  
to tie or truss the product being cooked. This  
prevents the product from moving around the spit  
and also prevents damage by preventing the legs and  
wings from flopping. In this section, we will show  
how to properly truss a chicken. It is important to  
use a tie to fit the size of the product. In this case,  
we are tieing a 2 3/4 lb. chicken with a 6” tie.  
Figure 2. Trussing Wings  
With the back of the chicken facing up, take the tie  
and wrap it around the breast, making sure to tuck  
the wings against the breast. Pull on the tie as  
pictured. You will also need to hold the chicken  
with your other hand.  
Figure 3. Trussing Accross Back  
While pulling on the tie, cross the strings so that you  
make an “X” across the back of the chicken. With  
the “loop” in your hand, you will now need to tie the  
legs of the chicken.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 23 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
Figure 4. Trussing Legs  
While pulling on the tie, loop the strings over the  
legs of the chicken.  
Figure 5. Trussed Legs  
Make sure that both legs are securely held by the tie.  
Figure 6. Trussed wings  
Make sure that both wings are securely held by the  
tie against the breast of the chicken.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 24 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
Figure 7. Pop-up Thermometer  
The only way to tell if a chicken is done is take the  
intermal temperature. Since it can be difficult to  
probe the chickens while they are in the rotisserie,  
we recommend the use of pop-up thermometer.  
These inexpensive items should be place in the  
thickest part of the chicken, which is the breast. The  
thermostat will “pop-out” when the internal tem-  
perature reaches 185º F.  
Figure 8. Chicken Ready to Spit  
With the chicken trussed and the pop-up thermom-  
eter in place, the chicken is ready to be spitted with  
an angle spit.  
Figure 9. Spitting Accessories  
In order to make the use of the angle spits fast and  
easy, we offer an accessorie called a Spit Holder  
(Hickory Part 195). This aluminum plate offers six  
holes where the base (square-end) of the angle spit  
can be inserted.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 25 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
Figure 10. Using the Angle Spit  
Insert the bottom (handle) of the spit into the Spit  
Holder.  
Figure 11. Spitting a Chicken  
Spit the chicken through the cavity. The chicken  
should be inserted through the “head” (or at least  
where the head used to be) first.  
Figure 12. Chicken Position on Spit  
When spitting the chicken, make sure that the breast  
is sitting on the flat, exterior side of the spit. Notice  
on the picture how the breast is not directly on the  
rounded corner of the spit, but above one of the flat  
parts of the “V”. It is also important to note that the  
legs (and the tie) must sit on the same flat side of the  
spit. This picture shows exactly how the chicken  
should look when spitted.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 26 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
Figure 13. Incorrectly Spitted Chicken  
This picture shows a chicken with the legs improp-  
erly placed. Note how the chicken seems to hang to  
one side. When spitted this way, the chickens will  
tend to “bounce” up and down causing the chicken  
to break-up.  
Figure 14. Complete Spit  
After inserting the first chicken, push it all the way  
to the bottom of the spit and add the next chicken.  
Depending on the size of the birds and on the  
rotisserie model, each spit will accommodate three  
to four 2 3/4 lb. chickens. Once completed, the spit  
is ready to be placed in the rotisserie.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 27 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
Figure 15. Inserting Single Bottom Skewer  
B. Using Regular Spits  
Attach a single skewer with a thumb screw at least 1/  
2" from the square end of the spit. The skewer must be  
on the round section of the spit.  
Figure 16. Fastening Bottom Skewer  
Use the "T" shaped tool supplied with the unit to  
tighten the thumb screw. This will prevent the bottom  
skewer from sliding off the screw.  
Figure 17. Using the Spit Holder  
Even though the chickens can be spitted on a work  
table,theuseoftheSpitHolder(HickoryPart195)will  
make the spitting process much easier.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 28 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
Figure 18. Inserting Chicken  
Take the chicken, with the drumsticks in the direction  
of the attached skewer, and slide the spit through the  
cavity of the chicken.  
Figure 19. Tucking the Legs  
The legs must be tucked between the skewer prongs  
and the center spit. Note that the bottom of the  
drum-  
stick is what is being locked in place.  
Figure 20. Pressing Chicken Towards Skewer  
When viewed from the breast side of the chicken,  
the bottom of the drum-stick is being pushed back  
while the meaty part of the leg is “puffed up” for  
better presentation. Note that the skewer is not  
going straight through the drum-stick!  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 29 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
Figure 21. Locking Wings  
The wings must be locked or tucked in place.  
When using the models N/5.5 and N/10.10, the  
locking method (pictured here) is only recom-  
mended with birds up to 2¾ lbs! With larger  
birds, the wings must be tucked under the breast,  
with elastic ties or “wing tuckers”. If the wings are  
locked on large birds, the wings on the adjacent  
spits will rub or catch, preventing the spits from  
rotating freely. This will cause the wings to break  
off or the gear mechanism to jam.  
Figure 22. Tucking Wings  
With larger birds, the wings must be tucked under  
the breast, with elastic ties or “wing tuckers”.  
Figure 23. Tucked Wings  
Notice how the wings are tucked agains the breast.  
By “tucking” instead of “locking” the wings, the  
working or rotating diameter of the chicken has  
been reduced.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 30 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
Figure 24. Inserting Double Skewers  
With the first chicken in place, insert a double skewer  
down the length of the spit into the shoulders of the  
first chicken. No thumb screw is required for the  
double skewers!  
WARNING! When driving the double skewer  
into the chicken, do not exert pressure from the  
end of the prongs! These are sharp and will  
pierce a finger or hand if not careful. Only  
apply pressure at the bottom of the "U" shaped  
half of the skewer!  
Figure 25. Double Skewer in Place  
With the double skewer in place, insert the next  
chicken down the length of the spit and position the  
chicken as previously described.  
Figure 26. Loaded Spit  
When the loading of the chickens is complete, the  
end of the spit must be locked in place with another  
single skewer.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 31 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
Figure 13. Completing the Load  
Slide a single skewer with a thumb screw into place  
from the top,  
Figure 14. Tightening Final Skewer  
Compress the chickens by exerting pressure on this  
last skewer, and tighten the thumb screw securely.  
Figure 15. Securing the Load  
Tighten the thumb screws with Hickory's thumb-  
screw tightening tool. This will prevent the chick-  
ens from coming loose.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 32 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
6. Loading and Unloading Spits  
On the N/45G, you do not need to open the front sliding glass doors of the machine in order to  
load the spits! If your unit is equipped with hinged side doors, these must be opened in order to  
insert and/or remove the spits. With the side(s) open, use a barbecue fork to grab a spit on one end,  
inside the single skewers. You can then use your free hand to hold the spit handle. With the motor  
switch on or off, first insert the round end of the spit and position it on the oil lite bushing on the  
center plate (see Figure 27). Then position the spit gear (next to the handle) so that it meshes with  
the shaft worm on the vertical drive shaft. Shift the spit from side to side so that the space formed  
between the spit collar and the spit gear fits fits (falls) onto the oil lite bushing on the spit plate.  
Reverse procedure to unload.  
Figure 27  
Shaft Worm  
Spit Plate  
Spit Gear  
Spit Collar  
OilLiteBushing  
Figure 28  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 33 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
7. Checking Chickens for Doneness  
Depending on the model being used, a 2 1/2 lb. chicken will take between 50 minutes and 1 hour 20  
minutes to cook in a pre-heated oven when the thermostat is set for MAXIMUM. By using a stem  
type thermometer, the operator MUST determine the interior temperature of the chicken to test for  
doneness. Chicken is done at 185°F. MAKE SURE TO REMOVE THE SKEWERS FROM  
BETWEEN THE CHICKENS PRIOR TO SERVING IT TO CUSTOMERS.  
8. Cooking other Products  
These units can be used to cook anything from quail to turkeys, pigs, lamb, goat, vegetables, potatoes,  
fish and much more. The baskets can be used for the cooking of chicken parts, brochettes and any-  
thing else that cannot go on a spit. A variety of other accessories is also available for specific types of  
products. Please consult the factory for a complete list of cooking accessories.  
9. Cleaning Instructions for Continuous Cook Rotisseries  
The most effective maintenance procedure that you can perform will be the daily clean-  
ing procedure  
Prior to First Cook:  
While the oven is still cold spray all interior panels with KOTE.  
FOR GAS MODELS  
Using the shield provided, cover the top row of ceramics and spray the interior of that  
area with KOTE. Repeat the process covering the remaining rows of ceramics.  
DO NOT SPRAY KOTE DIRECTLY ON THE CERAMICS OR THE PILOT LIGHTS.  
FOR ELECTRIC MODELS  
When spraying KOTE near the elements, adjust the spray nozzle pattern and try not to  
spray directly on the elements.  
RemovethewireracklocatedabovethedrippanandspraythesidesofthedrippanwithKOTE.  
Replace the wire rack and spray it with KOTE.  
After Each Cooking Cycle  
Spray the inside of the glass doors with an approved glass cleaner and wipe with a soft cloth.  
Drain the greasy water from the drip pan and replenish with fresh water.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 34 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
At The End of Each Day  
Turn burners valves or element switches to the OFFposition and allow the oven to cool down.  
Remove any spits or baskets allow them to soak for 15 20 minutes, using a solution of warm  
water and detergent. Rinse clean, following guidelines for rinsing & sanitizing.  
Remove the wire rack and clean it in the sink using a solution of warm water and detergent.  
Drainthegreasywaterfromthedrippanandreplenishwithasolutionofwarmwateranddetergent.  
Usingeitheraspongeoracloth -wipedowntheinterioroftheovenwiththesolutionremovingany  
grease/fat. Wipe dry the interior of the oven with a soft cloth.  
USE CARE WHEN CLEANING NEAR THE PILOT ASSEMBLY. IF YOU ACCIDENTALLY  
MOVE THE THERMOCOUPLE, BE SURE THAT YOU SNAP IT BACK INTO POSITION.  
Drain the solution from the drip pan, wipe clean and return to the oven along with the wire rack.  
Cleantheglasswithanapprovedglasscleaner.Donotuseabrasivesorrazorbladesastheywill  
mar and/or scratch the surface causing it to break without notice.  
Wipe clean the area around the controls with a sponge or soft cloth.  
GAS MODELS  
RE-LIGHT THE PILOTS AND TURN ON ALL BURNERS (SET TO HIGH).  
ELECTRIC MODELS  
TURN ON ALL OF THE ELEMENTS.  
RUN THE UNIT FOR APPROXIMATELY 5 MINUTES TO BURN OFF ANY CHEMICAL  
RESIDUE THAT MAY BE REMAINING FROM THE CLEANING PROCEDURE.  
RecommendationnowwouldbeagoodtimetospraytheinterioroftheovenwithKOTE. You  
will be prepared for tomorrows cooking cycle.  
NOTE:  
On a monthly basis, to ensure that the burner is operating efficiently, remove the  
ceramics and use a paper clip to clean any debris from the burner openings. Additionally the  
venturi air inlet gap needs to be cleaned. This can be done using a paring knife or business  
card. Refer to the operating manual.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 35 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
10. Maintenance Procedures for Continuous Cook Rotisseries  
Themosteffectivemaintenanceprocedurethatyoucanperformwillbethedailycleaning  
procedure.  
Monthly:  
Toensurethattheburnerisoperatingefficiently,removetheceramicsanduseapapercliptoclean  
anydebrisfromtheburneropenings.  
Toensureproperair/gasmixture,theventuriairinletgapneedstobecleaned. Thiscanbedone  
using a paring knife or business card. Refer to the operating manual.  
Every 6 Months:  
Toensurethattheshaftwormnylongearsproperlymeshwiththespitgears,placeaspitintoeach  
spitpositionwiththemotorrunning. Ifthegearsjumpordonotalignproperly, adjustthemusing  
the allen wrench provided DO NOT OVER TIGHTEN THE SCREWS.  
Every 12 Months:  
Inspect the spit plates and verify that the brass oil lite bushings are in place for each spit position.  
Replace any worn or missing bushings.  
Remove the glass and inspect for scratches and or chips. If any are found replace the glass as  
soon as possible. Also, inspect the glass trolleys. If they are worn, replace them.  
Units with sliding side doors the upper and lower slides needed to be greased.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 36 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
III.  
CRITICAL CONTROL STEPS FOR PREPARATION AND COOKING OF  
BARBECUE CHICKENS  
1.  
2.  
3.  
4.  
5.  
6.  
Clean and sanitize preparation sink.  
Clean and sanitize spits, skewers, and thumbscrews.  
Use only the designated sink for raw product.  
Rinse off chickens in the preparation sink.  
Follow product spit-up procedure in manual.  
Load spitted product into machine. Follow loading  
instructionsinmanual.  
7.  
Thoroughly wash and sanitize hands before touching  
switchesand/ordials.  
8.  
Follow operating instructions for oven operation.  
9.  
Check product for doneness as per instruction manual.  
10.  
Follow unloading procedures. Use a designated surface for cooked product  
only. Insure that no cross contamination occurs with any surface previously  
used for raw product, including employee hands.  
11.  
If placing product in a display warmer, ensure that the product temperature  
(NOT WARMER TEMPERATURE) does not fall below 140°F. Warmer tem-  
perature insures that the ambient air temperature in the warmer is correct, but  
does not insure product temperature.  
12.  
13.  
Advanced preparation and storage of spitted product should be in an autho-  
rized, properly covered and maintained bin set aside for storing spitted product  
in the walk-in refrigeration unit.  
THE MOST CRITICAL STEP IN THE PREVENTION OF CROSS CONTAMI-  
NATION IS THE HUMAN HAND. THEREFORE, HANDLING RAW PROD-  
UCT AND THE WASHING OF HANDS IS THE MOST CRITICAL CONTROL  
STEP IN PREVENTING CROSS CONTAMINATION.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 37 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hickory Industries, Inc.  
IV. WARRANTY  
HICKORY INDUSTRIES WILL WARRANTY ALL ROTISSERIES FOR ONE YEAR FROM  
THE DATE OF ORIGINAL INVOICE. WARRANTY INCLUDES ALL PARTS EXCEPT  
BULBS AND GLASS.  
WARRANTY CONDITION IS THAT ALL WARRANTY  
DOCUMENTS MUST BE SIGNED AND MUST BE RETURNED TO HICKORY BY THE  
USER AFTER RECEIPT OF THE ROTISSERIE. THE COMPANY (HICKORY) RESERVES  
THE RIGHT TO REVIEW ALL WARRANTY CLAIMS BY ITS AUTHORIZED  
REPRESENTATIVE AND IF NEGLIGENCE OR ABUSE IS FOUND, THE CLAIM WILL  
BE DISALLOWED.  
4900 Westside Avenue, North Bergen, New Jersey 07047 N/45 Series Manual12/00  
Page 38 of 38  
Tel: [201] 223-0050 Fax: [201] 223-0950  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Toddler Furniture 8824 User Manual
Grizzly Automobile Parts G0738 User Manual
Grizzly Chipper G0594 User Manual
Grizzly Power Roller G5771 User Manual
GTI Indoor Furnishings GLE M4 32 User Manual
Harbor Freight Tools Fan 36711 User Manual
Hasbro Board Games Movie Classics User Manual
HP Hewlett Packard Calculator 20B User Manual
Husqvarna Snow Blower 9027STE User Manual
Icom Marine Radio FP 561 User Manual