Instructions - Parts
Feed Pump and
Agitator Kits
312769D
EN
™
Supplies viscous materials from drums or 20 gallon hoppers to XM and XP70
plural-component sprayers.
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
working pressure and approvals.
®
®
Monark 5:1 Kit
T2 2:1 Kit
256275
President 10:1 Kit
Agitator Kit
256274
256276
256433
r_256275_312769_1A
r_256433_312769_1A
r_256276_312769_1A
r_256433_312769_1A
Download from Www.Somanuals.com. All Manuals Search And Download.
Warnings
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back
to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where
applicable.
WARNING
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent
fire and explosion:
•
•
Use equipment only in well ventilated area.
Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop
cloths (potential static arc).
•
•
Keep work area free of debris, including solvent, rags and gasoline.
Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes
are present.
•
•
•
•
Ground all equipment in the work area. See Grounding instructions.
Use only grounded hoses.
Hold gun firmly to side of grounded pail when triggering into pail.
If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment
until you identify and correct the problem.
•
Keep a working fire extinguisher in the work area.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
•
•
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
•
•
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information
about your material, request MSDS forms from distributor or retailer.
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.
•
•
•
•
•
•
Do not alter or modify equipment.
Use equipment only for its intended purpose. Call your distributor for information.
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
Do not kink or over bend hoses or use hoses to pull equipment.
Keep children and animals away from work area.
Comply with all applicable safety regulations.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or
swallowed.
•
•
•
Read MSDS’s to know the specific hazards of the fluids you are using.
Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
Always wear impervious gloves when spraying or cleaning equipment.
312769D
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Warnings
WARNING
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other body parts.
•
•
•
Keep clear of moving parts.
Do not operate equipment with protective guards or covers removed.
Pressurized equipment can start without warning. Before checking, moving, or servicing equipment,
follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating
area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic
fumes, burns, and hearing loss. This equipment includes but is not limited to:
•
•
•
•
Protective eyewear
Clothing and respirator as recommended by the fluid and solvent manufacturer
Gloves
Hearing protection
4
312769D
Download from Www.Somanuals.com. All Manuals Search And Download.
Feed Kit Models
Feed Kit Models
All kits fit drums or 20 gallon hoppers. Most packages include all air and fluid fittings and hoses. Approvals are only
for the pumps or agitator and not for the entire package.
Complete
Package
(fluid and air)
Maximum Fluid
Working
Maximum Air
Input Pressure
Approvals
(only for pumps and agitator)
Description
Pressure
256274
256275
256276
Agitator Kit with air
connection
100 psi
(0.7 MPa, 7 bar)
N/A
0359
II 1/2 G T3
ITS03ATEX11226
T2 2:1 Ratio Transfer 180 psi
405 psi
(2.8 MPa, 28 bar)
Pump Kit
(1.2 MPa, 12 bar)
Monark® 5:1 Ratio
Pump Kit
180 psi
(1.2 MPa, 12 bar)
900 psi
(6.2 MPa, 62 bar)
0359
0359
II 1/2 G T2
ITS03ATEX11228
President® 10:1 Ratio
Pump
90 psi
900 psi
256433*
256232
(0.62 MPa, 6.2 bar) (6.2 MPa, 62 bar)
II 1/2 G T2
ITS03ATEX11228
55 Gallon (200 Liter)
Drum Feed Kit,
includes agitator kit
256274 and 2:1 pump
kit 246275
See pump and agitator
approvals above.
N/A
N/A
N/A
N/A
256255
55 Gallon (200 Liter)
Drum Feed Kit,
includes agitator
256274 and 5:1 pump
kit 246276
See pump and agitator
approvals above.
*
Does not include air hose, air fittings, or strainer to connect to XM sprayer pump lower.
312769D
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Installation
Grounding
Install Feed Pump
NOTE: President 10:1 feed pump kit 256433 is only
recommended for drum feed applications and highly
viscous materials. Do not install in hoppers as this
parts.
The equipment must be grounded. Grounding reduces
the risk of static and electric shock by providing an
escape wire for the electrical current due to static build
up.
1. Refer to Setup instructions in pump manual before
installing in drum or hopper (H).
2. If installing either the pump in a drum, install pump
in drum and use bung adapter (B) to secure.
Connect grounding wire to grounding screw (Z) on back
of XM sprayer or any earth ground.
3. If installing the T2 pump in a hopper: Install T2
pump in lower ledge of hopper (H), and secure with
bung adapter (B).
1
8
Z
7
B
H
ti18686a
T2 2:1 pump shown in 20 gallon hopper
4. If installing 5:1 pump in a hopper:
1
22
C
B
r_256275_312769_5A
7
8
H
FIG. 1: XM Sprayer
ti18687a
5:1 pump shown in 20 gallon hopper
a. Install 5:1 pump in lower ledge of hopper (H).
b. Drop in bung adapter (B).
c. Install spacer (C).
6
312769D
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
d. Adjust pump so there is at least 2.5 in. (64 mm)
between the pump shoulder and the top of the
bung adapter (B).
Install Agitator
NOTICE
Keep agitator tightly mounted to hopper to prevent
damage to threads from vibration. Ensure that there
is no interference between base of hopper and shaft
of agitator.
e. Orient the two spacer halves on the pump shaft
so spacer contacts the pump shoulder.
f. Tighten the spacer using provided hardware.
1. Install agitator (A) in drum, or upper ledge of double
wall hopper (H), by screwing helix through hole and
screwing agitator housing into bung adapter (B).
g. Slide the pump down so that the pump shoul-
der, spacer, and bung adapter are in solid con-
tact.
a. If only using an agitator: Install nipple fitting (52)
and elbow fitting (53) into agitator air inlet.
h. Rotate pump so outlet hose is aligned as
desired.
Shown in 20 gallon hopper.
A
i. Thread bung adapter tight.
j. Tighten bung adapter bolt.
52
H
53
5. Connect swivel fitting (7) and fluid hose (8) to feed
pump fluid outlet.
54
B
6. Connect other end of fluid hose (8) to lower strainer
valve assembly (17).
r_256274_312769_3A
10
11
b. If using an agitator and a pump: Install nipple
(52), tee fitting (2), two nipples (3), elbow (53)
into agitator air inlet.
12
17
52
8
2
3
53
3
r_256276_312769_4A
54
7. Connect elbow swivel fitting (10) and fitting (11) to
sprayer pump fluid inlet. Connect lower strainer
valve (17) and nipple (12) to fitting (11).
r_256274_312769_4A
2. Screw air line fitting (54) into elbow fitting (53).
312769D
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
6. If only using an agitator:
Connect Air Lines
a. Connect air line (55) and coupler (56) into fitting
(54).
Shown in 20 gallon hopper.
Trapped air can cause the pump to cycle unexpectedly,
which could result in serious injury from splashing or
moving parts.
A
52
53
B
54
56
H
1. 5:1 Monark pump only: Install air regulator kit (22).
2. 10:1 President pump only: Remove 3/8 npt nipple
from air regulator kit (22). Install reducing nipple
(42) in air motor inlet and connect air regulator kit.
55
r_256274_312769_2A
3. Shut off air valves (V) at feed pumps (1).
256276 5:1 Pump Kit Shown
7. If using a feed pump and agitator:
a. For Monark 5:1 pump only: Interconnect tee fit-
ting (2) and quick disconnect fitting (23) on
pump with air hose (5).
1
V
256276 5:1 Pump Kit Shown
Shown in 20 gallon hopper.
22
quick disconnect
5
r_256276_312769_2A
23
4. If only using a Monark 5:1 or T2 2:1 feed pump:
Install air line (5) with quick disconnect coupler pro-
vided.
54
2
5. For President 10:1 Pump only: connect air line and
quick disconnect coupler, not included, to air regula-
tor (22).
55
5
ti18688a
8
312769D
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
b. For T2 2:1 pump only: Interconnect tee fitting (2)
and quick disconnect fitting (1b) on pump with
air hose (5).
256275 2:1 Pump Kit Shown
Shown in 20 gallon hopper.
C
1b
5
2
FIG. 3: XP70 Sprayer
Flush Before Using Equipment
55
The equipment was tested with lightweight oil, which is
left in the fluid passages to protect parts. To avoid con-
taminating your fluid with oil, flush the equipment with a
compatible solvent before using the equipment. Refer to
the Flushing section in proportioner manual.
5
r_256275_312769_3A
8. Remove one cap (C) from the air manifold (M) on
the sprayer and the connect air line from the agitator
or pump.
Operation
Refer to separate pump and agitator manuals for opera-
tion and maintenance instructions.
Troubleshooting/Repair
C
See supplied pump manual and agitator manual for
maintenance, troubleshooting, and repair procedures.
r_256275_312769_4A
FIG. 2: XM Sprayer
312769D
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Parts
Feed Pump Kits
Monark 5:1 Pump Kit 256276
T2 2:1 Pump Kit 256275
1
1
22
1a
1b
3
8
8
7
7
5
23
24
3
2
1
1
5
3
1
3
1
2
3
1
1
r_256275_312769_1
r_256275_312769_7A
Sprayer Pump Inlet Connection
10
11
12
1
Only used when agitator is used with pump. See page 12.
17
8
r_256275_312769_4
10
312769D
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Feed Pump Kit Parts
10:1 President Drum Feed Pump Kit,
256433
These parts are used in the T2 2:1 Pump Kit 256275
and Monark 5:1 Pump Kit 256276.
The President 10:1 feed pump kit is only recommended
for drum feed applications and highly viscous materials.
Ref.
1
Part
Description
Qty.
NOTE: Do not install in hoppers as this will result in
pulsation at the gun.
* 295616 PUMP, 2:1 transfer pump; manual
311882; includes 1a and 1b
† 218956 PUMP, 5:1 Monark, see manual
307044
1
1
Ref. Part No. Description
Qty.
8
41
217382 HOSE, coupled, 10 ft
157785 FITTING, swivel; 3/4-14 nps x
3/4-14 npt
1
1
1a*
1b*
2
3
5
7
8
10
11
12
17
QUICK DISCONNECT FITTING
COUPLER
1
1
1
3
1
1
1
1
1
1
1
104984 FITTING, tee; 1/4 npt (f)
156971 NIPPLE, short; 1/4-18 npt
212005 HOSE, coupled; 6 ft
118459 UNION, swivel, 3/4 in.
217382 HOSE, coupled; 10 ft
121571 ELBOW, female swivel
121620 REDUCER, 1 1/4 x 3/4 npt
C20487 NIPPLE, hex
42
44
22
159239 NIPPLE, pipe, reducing; 1/2 x 3/8
npt
239326 PUMP, president, 10:1; see man-
ual 308738
248829 KIT, regulator, air, feed pump
1
1
1
Does not include air line, air fittings, or strainer to
connect to sprayer pump lower.
256653 KIT, strainer and valve, lower; see
manual 312770
22†
23†
24†
248829 KIT, regulator, air, feed pump
208536 COUPLER, line, air
162453 FITTING; 1/4 npsm x 1/4 npt
1
1
1
44
*
T2 2:1 Pump Kit 256275 only.
42
† Monark 5:1 Pump Kit 256276 only.
8
22
Drum Feed Kits
41
T2 2:1 Ratio Transfer Pump with Agitator
Drum Kit, 256232
Kit includes an agitator, pump, strainer and valve, and
fitting to mount and connect on a 55 gallon (200 liter)
drum. See illustration on page 10.
Ref. Part
Description
Qty.
1
1
5:1 Ratio Monark Pump with Agitator Drum
Kit, 256255
Kit includes agitator, pump, strainer and valve, and fitting
to mount and connect on a 55 gallon (200 liter) drum.
r_23926_312769_1
Ref. Part
Description
Qty.
1
1
312769D
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Agitator Kit 256274
52
53
51
Detail A: Agitator and Feed Pump Air Fittings
54
56
52
2
3
53
57
3
54
55
agitator, page 12
r_256275_312769_5
Ref. Part
Description
Qty.
51
52
224854 AGITATOR, helix; manual 308175
151519 FITTING, nipple, reducing; 1/8 x
1/4
1
1
53
C19425 FITTING, elbow, 90°, female
1
54
55
56
57
169970 FITTING, line, air
212005 HOSE, coupled, 6 ft
114558 COUPLER, line, air
166846 FITTING, adapter
1
1
1
1
12
312769D
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
Technical Data
Maximum air input pressure
Agitator Kit 256274. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar)
T2 Feed Pump Kit 246275 . . . . . . . . . . . . . . . . . . . . . . . . 180 psi (1.2 MPa, 12 bar)
Monark 5:1 Feed Pump Kit. . . . . . . . . . . . . . . . . . . . . . . . 180 psi (1.2 MPa, 12 bar)
President 10:1 Ratio Pump . . . . . . . . . . . . . . . . . . . . . . . 90 psi (0.62 MPa, 6.2 bar)
Maximum fluid working pressure
T2 Feed Pump Kit 246275 . . . . . . . . . . . . . . . . . . . . . . . . 900 psi (6.2 MPa, 62 bar)
Monark 5:1 Feed Pump Kit. . . . . . . . . . . . . . . . . . . . . . . . 405 psi (2.8 MPa, 28 bar)
President 10:1 Ratio Pump . . . . . . . . . . . . . . . . . . . . . . . 900 psi (6.2 MPa, 62 bar)
312769D
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 312769
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2009, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Download from Www.Somanuals.com. All Manuals Search And Download.
Revised 02/2012
|