1. Safety  
Safety Guidelines  
This manual contains information that is important for you, the owner/operator, to know and understand.  
This information relates to protecting personal safety and preventing equipment problems. It is the  
responsibility of the owner/operator to inform anyone operating or working in the area of this equipment  
of these safety guidelines. To help you recognize this information, we use the symbols that are defined  
below. Please read the manual and pay attention to these sections. Failure to read this manual and its  
safety instructions is a misuse of the equipment and may lead to serious injury or death.  
This is the safety alert symbol. It is used to alert you to  
potential personal injury hazards. Obey all safety messages  
that follow this symbol to avoid possible injury or death.  
DANGER indicates an imminently hazardous situation which,  
if not avoided, will result in death or serious injury.  
WARNING indicates a potentially hazardous situation which,  
if not avoided, could result in death or serious injury.  
CAUTION indicates a potentially hazardous situation which,  
if not avoided, may result in minor or moderate injury.  
CAUTION used without the safety alert symbol indicates a  
potentially hazardous situation which, if not avoided, may result  
in property damage.  
NOTE indicates information about the equipment that you should  
pay special attention.  
WARNING! BE ALERT!  
Personnel operating or working around electric fans should read this manual. This  
manual must be delivered with the equipment to its owner. Failure to read this manual  
and its safety instructions is a misuse of the equipment.  
PNEG-552 100 Series Dryer  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
1. Safety  
Dryer Operation  
Thank you for choosing a GSI product. It is designed to give excellent performance and service for  
many years.  
This manual describes the operation and service for all standard 100 Series single fan grain dryers.  
These models are available for liquid propane or natural gas fuel supply, with either single phase  
230 volt, or three phase 220 or 440 volt electrical power.  
Our foremost concern is your safety and the safety of others associated with this equipment. We want  
to keep you as a customer. This manual is to help you understand safe operating procedures and some  
problems which may be encountered by the operator and other personnel.  
As owner and/or operator, it is your responsibility to know what requirements, hazards and precautions  
exist, and to inform all personnel associated with the equipment or in the area. Safety precautions may  
be required from the personnel. Avoid any alterations to the equipment. Such alterations may produce  
a very dangerous situation where SERIOUS INJURY or DEATH may occur.  
This equipment shall be installed in accordance with the current installation codes and applicable  
regulations which should be carefully followed in all cases. Authorities having jurisdiction should be  
consulted before installations are made.  
Emergency Stop  
The emergency stop switch is located on the upper control box on the door. Pushing the emergency stop  
switch will interrupt the control power and stop all dryer functions.  
Pushing the emergency stop switch does not interrupt the main power to the  
upper control box panel.  
6
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
1. Safety  
Safety Precautions  
READ THESE INSTRUCTIONS BEFORE OPERATION AND SERVICE  
SAVE FOR FUTURE REFERENCE  
1. Read and understand the operating manual before attempting to operate the dryer.  
2. NEVER operate the dryer while the guards are removed.  
3. Power supply should be OFF for service of electrical components. Use CAUTION in checking  
voltage or other procedures requiring the power to be ON.  
4. Check for gas leaks at all gas pipe connections. If any leaks are detected, DO NOT operate dryer.  
Shut down and repair before further operation.  
5. NEVER attempt to operate the dryer by jumping or otherwise bypassing any safety devices on the unit.  
6. Set pressure regulator to avoid excessive gas pressure applied to the burner during ignition and  
when the burner is in operation. See Chart on Page 25 for operating procedures. DO NOT exceed  
maximum recommended drying temperature.  
7. Keep the dryer clean. DO NOT allow fine material to accumulate in the plenum chamber. Clean grain  
is easier to dry. Fine material increases resistance to airflow and requires removal of extra moisture.  
8. Keep auger drive belts tight enough to prevent slippage.  
9. Use CAUTION in working around high speed fans, gas burners, augers and auxiliary conveyors  
which can START AUTOMATICALLY.  
10. Keep area around air inlet to the fan clear of any obstacles and combustible materials.  
11. BEFORE attempting to remove and reinstall any propeller, make sure to read the recommended  
procedure listed in the Service section of the manual.  
12. Make sure that capacities of auxiliary conveyors are matched to dryer auger capacities.  
Use Caution in the Operation of this Equipment  
This dryer is designed and manufactured with operator safety in mind. However, the very nature of a  
grain dryer having a gas burner, high voltage electrical equipment and high speed rotating parts,  
presents hazards to personnel which can not be completely safeguarded against without interfering with  
the efficient operation of the dryer and reasonable access to its components.  
Use extreme caution in working around high speed fans, gas-fired heaters, augers and auxiliary  
conveyors, which may start without warning when the dryer is operating on automatic control.  
Keep the dryer clean. Do not allow fine material to accumulate in the plenum  
chamber or surrounding the outside of the dryer.  
Continued safe, dependable operation of automatic equipment depends, to a great degree, upon the  
owner. For a safe and dependable drying system, follow the recommendations within the Owner’s Manual  
and make it a practice to regularly inspect the unit for any developing problems or unsafe conditions.  
Take special note of the Safety Precautions before attempting to operate the dryer.  
PNEG-552 100 Series Dryer  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2. Safety Alert Decals  
GSI Group recommends contacting the local power company and, having a representative survey the  
installation so that wiring is compatible with their system, and adequate power is supplied to your unit.  
Safety decals should be read and understood by all people in the grain handling area.  
If a decal is damaged or is missing, contact:  
GSI Decals  
1004 E. Illinois St.  
Assumption, IL 62510  
Phone: 217-226-4421  
A free replacement will be sent to you.  
Decal: DC-1224  
Decal DC-1224 is located in two places on the fan/heater control box.  
One is located on the lid and another one is on the front of the fan  
heater control box. An additional location for this decal is inside the  
upper control box for the dryer.  
Decal: DC-889  
Decal DC-889 has two locations. One is located  
inside the fan/heater control box and another one  
is on the dryer upper control box door next to the  
main power disconnect.  
8
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2. Safety Alert Decals  
Decal: DC-972  
WARNING!  
Decal DC-972 is located on the bottom auger belt guard and the front bearing plate  
(which is visible when the bottom auger belt guard is removed). An alternate  
location would be at the rear of the dryer for portable dryers equipped with the  
Front Discharge Option.  
Moving parts can crush  
and cut. Keep hands  
clear. Do not operate  
without guards in place.  
Failure to do so could  
result in serious injury.  
DC-972  
Decal: DC-971  
WARNING!  
Decal DC-971 is located on the bottom auger belt guard and the front bearing  
plate (which is visible when the bottom auger belt guard is removed). An  
alternate location would be at the rear of the dryer for portable dryers equipped  
with the Front Discharge Option.  
An additional location for decal DC-971 is the top auger belt guard (one on the belt  
guard cover and another one is on the inside belt guard body visible when the belt  
guard cover is removed).  
Automatically controlled  
belt drive can start at  
anytime. Keep hands  
clear. Failure to do so  
could result in serious  
injury.  
DC-971  
Decal: DC-974  
Decal DC-974 has several different locations. Two are located on the front end panel  
below the fan/heater. Two are located on the rear end panel below the rear access  
door. Two are located on the auger discharge box (one on the outside top and one on  
the inside of the flapper lid next to the discharge mercury switch). One more of these  
decals is located inside the plenum on the rear plenum closure door just inside the  
rear access door.  
Rotating auger will crush  
and cut. Auto equipment  
can start at anytime. Do not  
enter until electric power is  
locked in off position. Failure  
to do so will result in serious  
injury or death.  
DC-974  
PNEG-552 100 Series Dryer  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Safety Alert Decals  
Decal: DC-1227  
Decal DC-1227 is located on the  
fan/heater access door.  
DC-1227  
Decal: DC-1225  
WARNING  
Decal DC-1225 is located on the  
fan/heater access door.  
Stay clear of rotating  
blade. Blade could start  
automatically. Can cause  
serious injury. Disconnect  
power before servicing.  
DC-1225  
Decal: DC-1229  
WARNING  
Decal DC-1229 is located on each  
of the meter roll access doors.  
Rotating metering roll.  
Equipment can start  
automatically. Keep hands  
clear. Can cause serious  
injury. Disconnect power  
before servicing.  
DC-1229  
10  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Safety Alert Decals  
Decal: DC-973  
Decal DC-973 is located on the rear plenum access  
door (inside and outside).  
Automatic equipment can  
start at anytime. Do not  
enter until fuel is shut off  
and electrical power is  
locked in off position.  
Failure to do so will result  
in serious injury or death.  
DC-973  
Decal: DC-338  
3/4" MINIMUM  
BOLT DIAMETER  
Decal DC-388 is located on the  
hitch tongue.  
Hitch pin must be  
securely fastened and  
no less than 3/4" in  
diameter. Failure to  
follow installation  
instructions may result  
in property damage.  
DC-388  
Decal: DC-1249  
HUB TEMPERATURE  
NO GREATER THAN 150°F  
TIGHTEN TO  
Decal DC-1249 is located on  
the hitch tongue.  
90FT-LBS.  
150°  
Dryer must be  
towed empty and  
in accordance  
with state and  
provincial  
55-60 PSI  
COLD  
regulations.  
0
50  
100  
200  
250  
150  
CHECK AFTER 50 MILES AND EVERY 200 MILES  
DC-1294  
PNEG-552 100 Series Dryer  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Dryer Control Panel  
Figure 3A Grain Dryer Control Panel  
12  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Dryer Control Panel  
Dryer Control Panel Featuring the 100 Series Control System  
The control panel provides easy access to gauges and controls. The Competitor Series 2000 Control  
System is a computerized control system that gives instant information regarding dryer operation.  
Moisture Control  
The Series 2000 Dryer has a built in moisture control. It controls the moisture level of discharged grain  
by sensing grain column temperature.  
Moisture Control Switch  
This switch turns the power ON or OFF to the moisture control. The light beside the switch is illuminated  
when the grain column temperature is below the moisture control setpoint.  
Control Power Switch  
The power to the Competitor 2000 Control System is turned ON or OFF with this switch.  
Outside Light  
The dryer outside light is turned ON or OFF here.  
Drying Mode Switch  
This is used to select staged batch or continuous flow drying.  
Load Auger Switch  
This is used to select the operation of the fill auger. In both the AUTO and MANUAL position, the load  
auger will operate if the dryer is low on grain and will automatically shut off when the dryer is full. In the  
AUTO position only, the dryer will shut down after a preset period of time set on the out of grain timer.  
NOTE: If the load auxiliary motor overload relay is being utilized in the dryer control panel, this switch  
will also control the operation of the auxiliary equipment.  
Fan Switch  
The fan is turned ON or OFF with this switch. The ON position operates the fan continuously during  
staged batch and continuous flow modes. The AUTO position is used in batch mode only and allows the  
fan to shut down during the unloading operation if desired. The light comes ON only when air pressure  
is sensed.  
Heater Switch  
This switch is used to turn the burner ON or OFF. The ON position will operate the burner continuously,  
but only when the fan is running. The AUTO position is used in batch mode only and allows the heater  
to be turned OFF to cool the grain and during the unloading operation. The burner light comes ON only  
when flame is detected.  
PNEG-552 100 Series Dryer  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Dryer Control Panel  
Unload Switch  
The UNLOAD switch turns the metering rolls and discharge auger ON or OFF, and selects the operation  
of the metering rolls.  
In the 2 Speed position, if the MOISTURE CONTROL switch is ON, and the drying mode switch  
is turned to continuous flow, the metering roll speed will alternate between the high speed  
metering roll potentiometer setting and the low speed metering roll potentiometer setting,  
depending on the control signal from the moisture control thermostat. The discharge auger will  
operate continuously.  
In the 1 Speed position, if the MOISTURE CONTROL switch is ON, and the drying mode switch  
is turned to continuous flow, the metering roll speed will operate at the high speed metering roll  
potentiometer setting or turn off depending on the control signal from the moisture control  
thermostat. The discharge auger will operate whenever the metering rolls are operating.  
In both the 1 Speed and the 2 Speed position, if the MOISTURE CONTROL switch is OFF, and  
the drying mode switch is turned to continuous flow, the metering roll speed can be manually  
controlled by adjusting the high speed metering roll potentiometer. The discharge auger will  
operate continuously.  
If the drying mode switch is turned to staged batch, the UNLOAD switch should be set to the  
1 Speed position. The discharge auger and metering rolls will only operate during the unload  
cycle of the staged batch operation, and the speed of the metering rolls is adjusted using the  
high speed metering roll potentiometer.  
NOTE: If the unload auxiliary motor overload relay is being utilized in the dryer control panel, the same  
switch will also control the operation of the auxiliary equipment.  
Low Speed Metering Roll Potentiometer  
Use this to adjust the low speed of the metering roll when the 2 Speed automatic moisture control feature  
of the dryer is in use.  
High Speed Metering Roll Potentiometer  
Use this to:  
Set the high speed of the metering roll when the 2 Speed automatic moisture control feature of  
the dryer is utilized.  
Set the speed of the metering rolls when the 1 Speed automatic moisture control feature of the  
dryer is utilized.  
Set the speed of the metering rolls during continuous flow operation when the moisture control  
is not used.  
Set the rate of grain discharge from the dryer during the unload cycle of staged batch dryer operation.  
Dryer Power Start Switch  
This switch starts and operates the dryer based on switch settings. If other switch settings are in the OFF  
position, individual dryer components can be operated by turning the drying mode switch to continuous  
flow, pressing the dryer power start button and then turning on the desired dryer component.  
14  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Dryer Control Panel  
Dryer Power Stop Switch  
This switch stops all dryer functions. If an automatic dryer shut down occurs, first determine and correct  
the cause of the shut down. Press the dryer power stop button to reset the dryer before restarting.  
100 Series Control System  
The 100 Series System controls all timing functions and safety circuit checks. It is designed to simplify  
dryer operation by providing messages and warnings on its Liquid Crystal Display (LCD).  
Turning ON the 100 Series Control System  
Turn the CONTROL POWER switch to ON. The monitor will display “GSI” and the current software  
version number.  
Figure 3B 100 Series Dryer Control Panel  
PNEG-552 100 Series Dryer  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Dryer Control Panel  
Setting the Dry, Cool, Unload and Out of Grain Timers  
These switches are used to set the drying cycle times in the staged batch drying mode only. The drying  
mode switch must be in the staged batch position. Out of grain sets the length of time the dryer will run  
before shutting down when the load switch is in the AUTO position. To change the setting of these  
timers, follow these instructions:  
1. Press the PROGRAM (TIMERS) button until the “carrot” (See Figure 3C) is above the timer you  
want to modify.  
2. Use the UP and DOWN arrow keys to change from the present time to the desired setting. The new  
time is automatically accepted.  
3. Keep pressing the PROGRAM (TIMERS) button until the carrot disappears or press the mode  
select button once to exit.  
During the operation, the remaining time on each timer is displayed on the screen. If the power goes out  
or if the dryer is stopped, these times are saved by the controller. When the dryer is restarted the timers  
will continue timing down. The timers will return to their initial settings by pressing and holding the “stop”  
button for 5 seconds.  
“CARROT”  
Figure 3C Dryer LCD Display  
Setting the Load and Unload Delays  
The load delay is used to delay the starting of the load auger when the dryer is unloading to prevent the  
load auger from starting and stopping too often. The unload delay is used to control the amount of time  
the unload auger runs after the metering rolls stop to allow for auger clean-out.  
1. Press the PROGRAM (DELAYS) button until the carrot is under the time delay to be changed.  
2. Use the UP and DOWN arrow keys to change from the present time to the new one. The new time  
is automatically entered.  
3. Keep pressing the PROGRAM (DELAYS) button until the carrot disappears or press the mode  
select button once to exit.  
16  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Dryer Control Panel  
Setting the Moisture Control and Plenum Setpoint  
1. Press the PROGRAM (TEMPERATURES) button until the carrot is under the temperature setting  
to be changed.  
2. Use the UP and DOWN arrow keys to change from the present temperature to the new one. The  
new time is automatically entered.  
3. Keep pressing the PROGRAM (TEMPERATURES) button until the carrot disappears or press the  
mode select button once to exit.  
Dryer Safety Circuit  
The Competitor Series 2000 Control System continuously checks all safety circuits on the dryer and will  
automatically shut the dryer down should a problem occur. The cause of the dryer shut down will be  
shown on the LCD display. To restart the dryer after a safety shut down, first correct the reason for the  
shut down, and then press the dryer power stop button to reset the circuit. Press the start button.  
Figure 3D 100 Series Control System  
Monitoring Grain Temperatures, Plenum Temperature or Timers  
Use the mode select to decide which of the modes you want to view.  
Checking the Hour Meter  
Press the UP arrow key and the total hours on the machine are displayed along with the batch count  
and minutes since the last shut down in five (5) successive screens. The screens appear in the following  
order: Hours X 100, balance of hours, balance of minutes, batch count, and minutes since last shut  
down. For example, five (5) screens displaying 5 | 23 | 12 | 144 | 188 would be: 523 Hours, 12 minutes  
on the Hour Meter, Batch Count at 144 and 188 minutes since the last shut down.  
PNEG-552 100 Series Dryer  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Dryer Control Panel  
Special Features  
Dual Batch Drying Temperature Mode  
To greatly improve quality in batch mode, reduce the plenum temperature at the end of the  
drying cycle. This will reduce peak temperature that the grain on the inside of the column  
attains and thereby reduce over-drying.  
Enter dual batch drying temperature mode by switching ON dip switch number four (4), the  
fourth switch from the bottom, on the dip switches located inside the control box on the  
back of the computer control board. This enables two plenum and two grain temperature  
settings, high and low. Set these parameters the same way the single plenum and grain  
temperature settings are made. The first of each temperatures being set will be the low  
setting and will be indicated by the word “Low” on the screen. The second setting will be  
identified by “High” on the display screen.  
Typically, the plenum settings would be 170 for low and 230 for high and the low grain  
temperature setting would be 10° to 20° below the normal moisture control temperature  
setting which becomes the new high setting.  
Both capacity and quality will improve using this feature while operating in batch dry and  
cool or all heat modes.  
Emergency Cooling Mode  
To enter an emergency cooling mode, switch ON switch number seven (#7), which is the  
second switch from the top on the dip switch inside of the control box on the back of the  
computer control board. This initiates a mode in which only the dryer fan runs, in case there  
is a plenum temperature or grain high-limit warning. When either of these safeties shuts  
down the dryer, run the fan to help cool the grain and/or plenum high-limit back down to a  
safe level. After flipping the switch, press the Start button and only the fan will run for  
approximately five minutes.  
Burner ON/OFF Operation  
Due to changing fuel conditions and to aid in drying wheat and other low temperature grains in hot  
weather, an ON/OFF burner has been developed in recent years.  
By moving the third switch, number six (#6), on the dip switch located inside the control box on the back  
of the computer control board to ON, the burner can be changed from a high-low burner to an ON/OFF  
burner. The burner will operate exactly the same as the high-low burner, however, when the setpoint is  
reached, the burner cycles OFF instead of switching to a lower pressure. The vaporizer cools much more  
quickly and allows a closer tolerance on the setpoint and to operate at lower temperature rises.  
Safety Circuit Shut Down Messages  
Vapor High Temperature  
This shut down message indicates that the LP gas vapor temperature sensor, located in the gas pipe  
train downstream from the vaporizer has opened. This indicates that the vaporizer is running too hot and  
must be readjusted. This sensor is set at 200°F and automatically resets itself when cool.  
18  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
3. Dryer Control Panel  
Loss of Flame  
The flame sensor failed to detect a burner flame, indicating that the burner has failed to light. There is a  
problem with the flame sensing circuitry or the dryer is not getting burner fuel. The burner switch light  
will be lit any time flame has been sensed by the burner controls.  
Housing High Temperature  
The temperature high-limit, located on the fan/heater housing has opened, indicating an over  
temperature condition has occurred toward the rear of the fan/heater housing in an oblong covered  
electrical box. This control is set at 200°F and MUST BE MANUALLY RESET.  
Rear Discharge Warning  
The lid on the grain discharge box has opened, indicating that grain is not being taken away fast enough  
at the discharge box.  
Motor Overload  
One of the thermal overloads on either the fan, load, unload or auxiliary motors has opened, indicating  
an over current condition. The overloads MUST BE MANUALLY RESET.  
Grain High Temperature  
An over temperature condition has occurred in one of the grain columns, causing the control to shut  
down the dryer. This control is set at 210°F and automatically resets itself when cool.  
Out of Grain  
The dryer has run low on grain, and the out of grain timer has timed out, shutting the dryer down. The  
unload auger will clean-out the dryer if in continuous flow operation.  
Plenum High Temperature  
An over temperature condition has occurred inside the dryer plenum. This control is a 300°F limit and  
automatically resets itself when cool. See Emergency Cooling Mode on Page 18.  
No Airflow  
The contacts in the air switch have opened due to insufficient airflow for the burner to operate. The  
contacts in the air switch have opened due to the fan not turning, or the air switch may need adjusting.  
Air  
The air switch contacts have closed prior to the fan starting, indicating a free wheeling blade or improper  
setting of the air switch.  
Grain and Plenum High Temperature (Both at Same Time)  
If both of these warnings appear on the screen at the same time, one of the two mechanical high-limits,  
located in each of the two grain columns, has been tripped due to heat exceeding their 200° setpoint or  
one or both have failed. They will automatically reset when the temperature returns below 200°.  
NOTE: The emergency cooling feature will not function if either or both of these mechanical sensors  
are tripped.  
PNEG-552 100 Series Dryer  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Error Conditions  
Figure 4A  
20  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4. Error Conditions  
Figure 4B  
PNEG-552 100 Series Dryer  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Dryer Pre-Start Checks  
Before the dryer is filled, thoroughly inspect the unit and check the operation of the dryer as follows.  
Inspect the Metering Rolls  
Figure 5A Asco Safety Shut Off Valve  
Open all metering roll access doors and inspect each compartment for any bolts, nuts or other foreign  
material, that may cause possible jamming of the metering rolls.  
Before attempting to operate the dryer make sure all safety shields are in place,  
all bottom clean-out and rear access doors are closed and all personnel are  
clear of the dryer.  
Set Control Switches  
Moisture Control Switch  
Moisture Control Thermostat  
Load Switch  
OFF  
200°  
OFF  
Unload Switch  
Fan Switch  
OFF  
OFF  
Burner Switch  
Out of Grain Timer  
Load Delay  
OFF  
1 MINUTE (Reset to 8 Minutes after testing)  
30 SECONDS  
Unload Delay  
30 SECONDS  
Metering Roll Speed  
Dry Timer  
LOW AND HIGH SPEED SETTINGS PUT ON ZERO  
60 MINUTES  
Cool Timer  
20 MINUTES  
Unload Timer  
10 MINUTES  
Mode Switch  
CONTINUOUS FLOW  
22  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5. Dryer Pre-Start Checks  
Electrical Power  
Turn ON the electrical power supply to the dryer. Set all circuit breakers to ON, including the safety  
disconnect handle mounted on front of the dryer’s power panel.  
Control Power Switch  
Turn the CONTROL POWER switch to ON. The switch light comes on. “GSI” and the software version  
will appear. At this point, the controller will lock out all other dryer functions and the dryer will perform its  
safety circuit check. If a fault is found, the cause will be displayed on the LCD. If all safeties are found  
safe, the controller will supply power to the electronic fuel shut off valve (if so equipped). Press the start  
button to initialize the computer.  
Power Start Button  
Push the dryer start button, and all the toggle switches on the control panel will be activated. This  
initializes the load, fan, burner, unload and metering rolls individually.  
Fuel Check  
If using LP gas, make sure the tank has plenty of fuel and that the TANK DOES NOT HAVE A PRESSURE  
REGULATOR MOUNTED TO IT. If using natural gas, make sure an adequate supply is available.  
If using LP gas, slowly open the main fuel supply valve at the tank. If using natural gas, turn ON the valve  
along the supply line. Then, open the electronic shut off valve (Asco valve), if so equipped, or open the  
manual shut off valve on the dryer to allow fuel flow to the dryer. Inspect all gas lines and connections  
for possible leaks. ANY GAS LEAKS NEED TO BE FIXED IMMEDIATELY.  
Load Auger  
With the grain supply shut off, quickly bump the load auger switch to MANUAL and see if the load auger  
rotates clockwise, as viewed from the drive end, or counterclockwise if the dryer is a front load model.  
If the wet grain supply auxiliary is wired to the dryer it should also rotate in the correct direction at this  
time. Turn the load auger switch to the AUTO position. The top auger and wet grain supply auxiliary  
should run for one minute and then the dryer will shut down leaving the safety shut down message (out  
of grain) displayed. Press the dryer power stop button to reset the panel, then press the start button to  
resume operation.  
1 Speed Operation  
To check 1 Speed operation, place the unload switch in the 1 Speed setting. Turn the high speed  
metering roll dial up until the metering rolls start rotating. The bottom auger should rotate  
counterclockwise, as viewed from the drive end. The metering roll drive motor should rotate clockwise,  
as viewed from the drive end of the gear box. If the dry grain take away auxiliary is wired to the dryer, it  
should start and rotate in the proper direction.  
PNEG-552 100 Series Dryer  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
5. Dryer Pre-Start Checks  
Metering Roll Operation  
To check the metering roll operation, turn high speed knob clockwise. The metering roll speed should  
increase. Turning the knob counterclockwise will decrease the speed. Turn ON the MOISTURE  
CONTROL switch. If the Grain Temperature Setpoint is set above the outside temperature, the system  
will switch to Low Speed if working correctly. Make sure the drive chain tension is properly adjusted and  
all sections of the metering rolls rotate. Turn the unload switch OFF after these checks are complete. The  
bottom auger will continue to run for 30 seconds after the switch is turned OFF to allow for clean-out.  
Figure 5B The Metering Roll Access Area  
Fan Switch  
Bump the FAN switch and observe the fan rotation. The fan should run counterclockwise. Sometimes  
on three phase models all motors on the dryer will run backwards. They can easily be reversed by  
interchanging two of three power supply wires. Reverse the two outside wires, L1 and L3 and leave the  
middle one in the same position.  
NOTE: If the dryer is empty, the burner does not operate. The fans cannot create enough static pressure  
to engage the air switch. You will receive a “no airflow” message. To start the dryer when it is low  
on grain, the airflow switches must be turned OFF. Switching Dip Switch number eight (#8), on  
the back of the computer control board, to ON turns the Air Switch OFF.  
Dip switch number eight (#8) must be turned back to the OFF position after this  
test is complete or no air testing will occur.  
24  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5. Dryer Pre-Start Checks  
Burner Safety  
To check the burner safety function, make sure the main gas valve is OFF. Turn the FAN switch ON and  
allow the fan to start. Then, turn the HEATER switch ON. The dryer will shut down after 20 seconds. The  
safety message, “loss of flame” will appear.  
Heater Test Fire  
The following test should be done with grain in the dryer. If no grain is present, set approximate pressure  
settings and fine tune when grain arrives. Test fire the burner by starting the fan, and then turn the burner  
switch to ON with the fuel supply turned on. The heater should ignite after a short purge delay of  
approximately 10 seconds. Gas pressure should be shown on the gauge. At this time, set the high-fire  
and low-fire pressure settings. Use the pressure regulator (See #1 on Page 26) for high-fire and the  
needle valve located in the side of the Cycle Solenoid (low fire) Valve (See #2 on Page 26) for low-fire.  
The burner should cycle between high and low-fire, approximately 2 or 3 times per minute.  
Approximate settings should be:  
LP Gas  
High-Fire 6-15 lbs.  
Low-Fire 2-6 lbs.  
Natural Gas  
High-Fire 6-10 lbs.  
Low-Fire 1-3 lbs.  
If the burner remains on high-fire and does not cycle, increase the regulator setting on the propane  
models, or the supply valve on the natural gas models, in order to reach the thermostat setting. If the  
burner remains in low-fire and does not cycle, slightly decrease gas pressure with the low-fire solenoid  
needle valve. If the gas pressure is decreased too much, a popping or fluttering sound will be heard. Be  
sure to adjust the low pressure needle valve anytime the high pressure regulator is adjusted.  
Staged Batch Check  
The following test must be done with grain in the dryer or with the air switch turned OFF as noted in the  
FAN switch Section on Page 24. To check the staged batch operation, turn the CONTROL POWER  
switch to the ON position. Open the main fuel supply valve at the tank on an LP dryer or open the valve  
in the fuel supply line on a natural gas dryer. Turn the drying mode switch to the staged batch position.  
Turn ON the electric shut off valve to allow fuel flow to the dryer. Turn the load switch to AUTO, the  
unload switch to 1 Speed and the fan and burner to ON. Push the dryer power start button and the  
controller will sequentially start all dryer components in their proper order. If any switches are not in their  
correct position for staged batch operation, the dryer will indicate improper switch position, and will not  
start until the switches are in the proper position. After starting, all batch timers will time down in  
sequence. When the unload cycle is complete, the timers will automatically reset to their original  
settings, and start the dryer timer again.  
NOTE: If the dryer is empty, the burner does not operate. The fans cannot create enough static pressure  
to engage the air switch. You will receive a “no airflow” message. To start the dryer when it is low  
on grain, the airflow switches must be turned OFF. Switching Dip Switch number eight (#8), on  
the back of the computer control board, to ON turns the Air Switch OFF.  
Dip switch number eight (#8) must be turned back to the OFF position after this  
test is complete or no air testing will occur.  
PNEG-552 100 Series Dryer  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
5. Dryer Pre-Start Checks  
Dryer Shut Down  
To shut down the dryer, first close the fuel supply valve at the tank or valve along the fuel line. If the  
burner is operating, let the dryer run out of fuel, and it will shut down automatically due to loss of flame.  
Close the fuel valve at the dryer, and press the dryer power stop button. Turn OFF the safety disconnect  
handle on the front of the power box, and turn OFF the main power to the dryer.  
Stopping Dryer Operation  
To stop operation of the dryer, push the dryer power stop button. The fan, burner and all augers will  
stop immediately.  
Emergency Stop  
In case of emergency, push the emergency stop button located at the bottom of the Upper Control Box.  
Figure 5C  
The dryer fan/heater controls featuring:  
Ref #  
Description  
Pressure Regulator  
1
2
3
4
5
Low-Fire Solenoid Adjustment  
High Pressure Solenoid  
Low Pressure Solenoid  
Supply Line Solenoid  
26  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
6. Dryer Start-Up  
Continuous Flow Operation  
Standard electrical safety practices and codes should be used when working with a dryer. Refer to the  
National Electric Code standard handbook by the National Fire Protection Association. A qualified  
electrician should make all wiring installations.  
Always disconnect and lock out power before working on or around dryer.  
Full Start-Up Check  
This start-up procedure assumes the following:  
1. You have read and understand the DRYER OPERATION AND SERVICE MANUAL.  
2. You have taken special note of all SAFETY PRECAUTIONS.  
3. All safety shields are in place.  
4. All meter roll access doors have been opened and all foreign objects have been removed.  
5. A pre start-up check has been performed.  
6. All motors have been checked for proper rotation.  
7. All heaters have been test fired.  
8. The fuel has been turned ON at the tank.  
9. The electric power has been turned ON.  
10. The main disconnect switch on the dryer is ON.  
11. There is wet grain in the wet holding bin.  
12. The incoming grain moisture is known.  
13. Dry grain take away equipment is in place.  
14. Grain is going to the proper bin.  
15. All switches have been set to the OFF position.  
16. The load tilt switch box is installed with the side stamped up, in the UP position.  
Filling the Dryer  
1. Turn the CONTROL POWER switch to ON.  
2. Turn the drying mode switch to CONTINUOUS FLOW.  
3. Make sure the FAN, BURNER and UNLOAD switches are in the OFF position.  
4. Push the DRYER POWER START switch.  
5. Turn the LOAD AUGER switch to the MANUAL position to fill the dryer. The load auger should start  
and run until the dryer is full, then shut off automatically. (If the switch is set to the AUTO position,  
the dryer will shut down each time the out of grain timer times out, and will have to be restarted.)  
6. When the dryer has filled, turn the LOAD AUGER switch to the AUTO position.  
PNEG-552 100 Series Dryer  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
6. Dryer Start-Up  
Staged Batch Operation  
1. Turn the CONTROL POWER switch to ON.  
2. With load, unload, fan and burner turned OFF, turn the drying mode switch to continuous then push  
the dryer power start switch to arm the safety circuit. Turn the LOAD switch to ON and Fill the dryer  
with grain. The load auger will stop when full if the LOAD TILT Switch is installed and set properly.  
3. Turn the drying mode switch to staged batch.  
4. Open the main fuel supply valve on the tank if using LP gas, or the valve in the fuel supply line if  
using natural gas. Turn ON the electric shut off, Maxon valve (if so equipped), or open the manual  
shut off valve to allow fuel flow to the dryer.  
5. Set switches to the following settings:  
Load  
AUTO (For timed shut down when out of grain. ON will shut off auger when  
full, but will not shut dryer down when out of grain.)  
Fan  
AUTO (To Stop during Unloading. ON to Continue Cooling during Unloading.)  
AUTO (For Dry and Cool. ON for All Heat.)  
1 Speed  
Heater  
Unload  
Fan/Heater Switch Settings  
Fan Setting  
Heater Setting  
Fan Function  
Heater Function  
Burners stay ON during dry timer  
cycle only  
AUTO  
AUTO  
Fans stay ON during dry and cool cycle only  
AUTO  
ON  
ON  
ON  
Fans stay ON during dry and cool cycle only  
Fans are ON continuously  
Burners stay ON during dry and cool  
Burners are ON continuously  
Burners shut down at the end of the  
dry cycle  
ON  
AUTO  
Fans are ON continuously  
At the end of the dry cycle in staged batch, the fans and heaters will continue running if the MOISTURE CONTROL is “ON”,  
until the preset temperature on the moisture control thermostat is reached.  
6. Make sure the load auger switch is set to AUTO. In both the AUTO and MANUAL position, the  
grain level switch will automatically keep the dryer full of grain. In the AUTO position, the dryer will  
shut down after the preset time period on the out of grain timer, or if the grain flow to the dryer  
is interrupted.  
7. To properly set the correct dry, cool and unload time for various moisture content grains, see the  
chart on Page 30.  
8. To start the drying operation, push the dryer power start button.The controller will start all the dryer  
components in their proper order. If any of the selected switches are improperly positioned for  
staged batch drying, the display will indicate the proper switch position, and will not allow the dryer  
to operate until the position of the switch is corrected.  
9. The fan will start and airflow is checked.  
28  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6. Dryer Start-Up  
10. After purging for approximately 10 seconds the heater will fire. For information concerning heater  
11. If the dryer is being operated in all heat, move the FAN switch to the ON position. In this position,  
the fan will run continuously during the dry, cool and unload stages of the staged batch operation.  
If the dryer is being operated in the dry and cool mode, the preferred position for the FAN switch is  
the ON position, so the fan will run continuously and continue to cool the grain during the unload  
operation. If desired, the fan can be turned OFF during the unload cycle of the dry-cool-unload  
sequence by turning the FAN switch to AUTO.  
12. If the dryer is being operated in all heat, move the HEATER switch to ON. The burner will operate  
whenever the fan is operating. If the dryer is being used in dry and cool, turn the HEATER switch  
to AUTO and the burner will automatically shut down during the cooling and unloading cycles.  
13. The bottom auger and metering rolls will start automatically during the unload cycle of the  
dry-cool-unload mode, along with any grain handling equipment that is wired to the dryer. The  
speed at which the metering rolls operate during the unload cycle is adjusted by using the high  
speed metering roll knob. Turning the dial clockwise will increase the grain discharge rate, and  
turning it counterclockwise will decrease the discharge rate.  
14. When the last batch is done and the dryer is out of grain, turn the drying mode switch to continuous.  
Turn the load, unload, fan/heater switches off and push the dryer power start switch to arm the  
safety circuit. Run the fan/heater manually for 6 minutes per point of moisture to be removed.  
Turn the burner off to cool the grain for 30 minutes. Turn off the fan and manually unload the dryer  
by turning the unload switch to 1 Speed and setting the meter rolls as fast as the unload equipment  
will allow.  
15. To control the length of the dry cycle using only the dry time setting programmed into the system,  
turn the MOISTURE CONTROL setting to OFF. To use the automatic moisture control so that the  
dry time is determined, not only by the dry time setting, but also by the moisture content of the  
drying grain, turn the MOISTURE CONTROL switch to ON.  
16. To shut down the dryer, close the fuel supply valve at the fuel tank or fuel source. If the burner is  
operating, let the dryer run out of fuel, causing an automatic shut down due to a loss of flame. Close  
the fuel valve at the dryer, and press the dryer power stop button. Turn OFF the dryer’s main circuit  
breaker located on the front of the power panel. Turn OFF the main power supply to the dryer.  
17. In case of an emergency, press the dryer power stop button. The burner, fan and all augers will  
stop immediately.  
PNEG-552 100 Series Dryer  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Dryer Start-Up  
100 Series Batch Timer Settings  
Full Heat  
Dry and Cool  
Fans on MANUAL Burners on AUTO  
Fan and Burner Switches on MANUAL  
Approx. Dry Cool Unload*  
Moisture (%) Removed (pts.) Dry Time (min.) (min.)  
Initial  
Moisture  
Approx. Dry  
Dry Time (min.) (min.)  
Cool  
(min.)  
Unload*  
(min.)  
(min.)  
(min.)  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
17.0  
18.0  
19.0  
20.0  
21.0  
22.0  
23.0  
24.0  
25.0  
26.0  
27.0  
28.0  
29.0  
30.0  
31.0  
32.0  
33.0  
34.0  
35.0  
2.0  
3.0  
16.0  
21.0  
26.0  
31.5  
37.0  
41.5  
47.0  
51.0  
54.0  
58.0  
62.0  
66.5  
71.5  
76.0  
81.0  
86.0  
91.0  
96.0  
100.0  
6.0  
11.0  
16.0  
21.5  
27.0  
31.5  
37.0  
47.0  
44.0  
48.0  
52.0  
56.5.  
61.5  
66.0.  
71.0  
76.0  
81.0  
86.0  
90.0  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
18.0  
24.0  
30.0  
35.0  
40.0  
45.0  
50.0  
55.0  
60.0  
65.0  
70.0  
75.0  
80.0  
85.0  
90.0  
95.0  
100.0  
105.0  
110.0  
18.0  
24.0  
30.0  
35.0  
40.0  
45.0  
50.0  
55.0  
60.0  
65.0  
70.0  
75.0  
80.0  
85.0  
90.0  
95.0  
100.0  
105.0  
110.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
18.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
4.0  
5.0  
6.0  
7.0  
8.0  
9.0  
10.0  
11.0  
12.0  
13.0  
14.0  
15.0  
16.0  
17.0  
18.0  
19.0  
20.0  
These are approximate starting points.  
*Set unload meter roll high speed setting to 999. If unload equipment cannot adequately keep up, lower  
the speed setting and add time to the unload timer setting to completely unload the batch. In full heat  
mode, the time added to the unload timer will need to be subtracted from the dry timer. If fan is on AUTO  
and does not run during unload, set cool timer to 25 minutes.  
New unload time calculation = present unload time ÷ new dial setting  
1000  
Example: 13.75 = 11 ÷ 800  
1000  
Starting the Dryer  
This start-up procedure is for a cold start on wet grain for continuous flow operation.  
1. Turn on the LP gas tank and any other manual gas valve at this time. Set the MAXON or FAST  
ACTION HAND VALVE, if so equipped, on the incoming fuel line to the ON position.  
2. Make sure the MOISTURE CONTROL switch is in the OFF position.  
3. Turn the FAN switch to the ON position.  
4. Adjust the AIR PRESSURE SWITCH if necessary.  
5. Turn the HEATER switch to the ON position. The heater will purge for about 10 seconds then ignite.  
If flame is detected the dryer will run, if not, a “loss of flame” error will occur. If this happens, check  
gas supply, and all valves in the fuel line to make sure they are ON and attempt again.  
30  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
6. Dryer Start-Up  
Adjusting the Temperature  
1. Press the PROGRAM(TEMPERATURES) button until the “carrot” is above the timer to be modified.  
2. Use the UP and DOWN arrow keys to change the present temperature to the desired setting. The  
new temperature is automatically accepted.  
3. Keep pressing the PROGRAM(TEMPERATURES) button until the carrot disappears or press the  
MODE SELECT button once to exit.  
4. On LP gas models, adjust the PRESSURE REGULATOR (high-fire) on the burner fuel line, so that  
burner will reach the thermostat setting and switch to low-fire. Pressure up to 25 lbs. may be  
required. Natural gas does not have a regulator, but uses a LARGE BALL VALVE close to the  
vertical supply line for adjustment. Pressure up to 18 lbs. may be required.  
The Approximate Settings should be:  
LP Gas  
High-Fire 6-15 lbs.  
Low-Fire 2-6 lbs.  
Natural Gas  
High-Fire 6-10 lbs.  
Low-Fire 1-3 lbs.  
Do not set the low-fire pressure so low that a popping or fluttering sound is heard in the heater. If  
popping or fluttering sound are heard, increase the pressure until the sound goes away.  
On LP and NG gas models adjust the needle valve on the cycle solenoid (low-fire valve) so that  
the burner maintains flame then switches back to high-fire.  
5. Adjust the burner pressure so that the burner CYCLES 2 to 3 times per minute (approximately 15 to  
20 seconds on HIGH and approximately 5-8 seconds on LOW). Increasing the gas pressure with the  
LP gas regulator or the Natural Gas hand valve increases the cycling rate and lowering it decreases  
the rate. This is the primary way to change the cycling rate.  
Decreasing the low pressure setting with the needle valve will also increase the rate while increasing  
that pressure will decrease the rate.  
6. On LP gas models adjust the vaporizer so the fuel pipes going to the burner from the regulator are  
warm to the touch (not hot and cold).  
The vaporizer can be adjusted two ways. First, by loosening the bolt in the hinging mechanism and  
swinging it to a hotter or cooler position. Second, by loosening the two bolts in the hinge pipe and sliding  
the vaporizer in or out to a cooler or hotter position. Either one or both methods may need to be used to  
get the vaporizer to the proper temperature, but the first almost always gives adequate adjustment.  
Natural gas does not use a vaporizer.  
PNEG-552 100 Series Dryer  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
6. Dryer Start-Up  
Full Heat Continuous Flow Operation  
1. Refer to the DRYER START-UP section of the Operator’s Manual. (CONTINUOUS FLOW METER  
indicates the initial moisture. These are the settings referred to throughout this start-up procedure.  
2. Make sure the UNLOAD switch is OFF.  
3. Make sure the MOISTURE CONTROL switch is OFF.  
4. If the dryer is stopped, press the dryer start switch to lock in the control circuit.  
5. Turn the fan and burner switches to the “ON” position to run fans and burners. Be sure to adjust the  
plenum temperature to 180°F for all burners. Run the fans and burners for about 10% longer than  
the approximate dry time (from chart on Page 33) for the incoming moisture. Example: 10 pt.  
removal from the chart is 54 minutes, plus 5.4 minutes (10%) equals 59.4 minutes (round up to 60).  
6. Increase the drying temperature to a maximum of 210°F (corn) for single fan dryers. For multiple  
fan dryers adjust the top burner to a maximum of 230°F (corn) and stage the temperature of the  
lower burners down 30° per burner. Example: 3 fan dryer Top burner: 230°, Middle burner: 200°,  
Bottom burner: 170°.  
7. After the initial fan and burner run time, set the unload switch to “1 Speed” and set the high speed  
meter roll potentiometer to the setting for 1 Speed (see chart on Page 33). Meter rolls should start  
and grain will begin to flow from discharge of dryer. Run time for this step should be the same as  
from Step 5 above. DO NOT TO ADJUST THE DRYER DURING THIS PERIOD. The grain  
discharging towards the end of this period will be over dried, but it is necessary so that the corn  
moisture is staged properly and evenly in the dryer.  
8. Turn the Moisture control switch to “ON”. Set the moisture control (grain) temperature to 100°F.  
9. Turn the Unload switch to “2 Speed”. Find the “2 Speed High” and “2 Speed Low” meter roll settings  
(see chart on Page 33) and set meter roll potentiometers accordingly. Allow the dryer to run for the  
time established in Step 5 and then sample the grain. If the dryer has been cycling regularly from  
high to low and the grain is not coming out to moisture desired, then adjust the moisture control  
(grain) temperature up or down 5° per point of moisture. Example: Moisture control is set to 100°,  
desired moisture is 15%, sampled moisture is 17%. Adjust moisture control to 110°. EVERY TIME  
AN ADJUSTMENT IS MADE IT IS IMPERATIVE THAT THE DRYER IS ALLOWED TO RUN FOR  
THE ESTABLISHED TIME IN ORDER FOR CHANGES TO TAKE AFFECT. Repeat this process  
as necessary until desired moisture content is being discharged from dryer.  
10. After the run time in Step 9, the moisture control and the meter roll speeds can be adjusted if  
required. Each time an adjustment to the moisture control is made, it will take approximately the  
time as shown in the example in Step 5 to see the results of this adjustment.  
32  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
6. Dryer Start-Up  
100 Series Continuous Flow Metering Roll Settings  
Full Heat  
Initial  
Moisture (%)  
Moisture  
Removed (pts.)  
Approximate  
Dry Time (min.)  
2 Speed  
2 Speed  
High  
1 Speed  
Low  
317  
270  
241  
213  
196  
185  
172  
161  
150  
140  
132  
123  
116  
110  
104  
100  
096  
087  
082  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
2
3
16  
21  
625  
476  
385  
317  
270  
241  
213  
196  
185  
172  
161  
150  
140  
132  
123  
116  
110  
104  
100  
875  
775  
675  
575  
476  
385  
317  
270  
241  
213  
196  
185  
172  
161  
150  
140  
132  
123  
116  
4
26  
5
31.5  
37  
6
7
41.5  
47  
8
9
51  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
54  
58  
62  
66.5  
71.5  
76  
81  
86  
91  
96  
100  
These are approximate starting points.  
Adjusting the Moisture Control  
1. 5° on the moisture control will change the output moisture by about 1%. Example: With 100° set,  
the result is 16% corn but 17% corn is desired. Reduce the moisture control setpoint temperature  
by 5° to 95°. This should change the moisture out to about 17%. If you want the corn to come out  
dryer, raise the temperature on the moisture control setpoint.  
2. Four (4) sensors are averaged together for sensing moisture control temperature, one (1) on each  
side of the dryer in the front, and one (1) on each side of the dryer in the back. They are located  
about 1/3 of the way up the grain column from the bottom, and in from the side about 4''.  
3. Grain temperatures can be monitored by pressing the mode select button.  
4. The moisture control should stay on HIGH about 50% to 90% of the time. There is a broad range  
that will work. It should switch from low to high and back again to maintain the desired moisture. A  
control that does not switch will not maintain an evenly dried grain moisture when the incoming wet  
grain moisture varies.  
5. If the metering roll switches to LOW and stays there for long periods of time, both the High  
and Low Speed Potentiometers should be slowed down 2% (20 points) and monitored for  
further adjustment.  
6. If the metering roll switches to HIGH and stays on HIGH more then 90% of the time, increase the  
speed on both Potentiometers 2% (20 points) and monitor for further adjustment.  
7. When adjusting the METER ROLL SPEEDS it is better not to change the speed more than 20 points  
(2%) at a time.  
8. Anytime a change is made, wait the approximate dry time for that moisture grain from the Chart  
above before checking the grain moisture level and making another change if necessary.  
PNEG-552 100 Series Dryer  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                   
7. Service  
Seasonal Inspection and Service  
The dryer is made of weather resistant material, and is designed to require a minimum of service.  
However, each season we recommend the following items be checked before the unit is used and any  
damaged or questionable parts replaced. These checks will help eliminate possible failures, and assure  
dependable operation of the equipment.  
Always shut off and lock out power before servicing.  
1. Shut OFF electrical power. Open power box and control box, and inspect for moisture, rodent  
damage or accumulated foreign material. Remove any foreign material present. Inspect and tighten  
any loose terminal connections. Replace any damaged or deteriorated wiring.  
2. Check propeller for freedom of rotation and uniform tip clearance. It should also be inspected for  
dirt and grain dust, especially inside the hub. Any additional weight can seriously affect the balance,  
and result in harmful vibrations and a short bearing life.  
3. Check propeller for free play. Any side play is an indication of defective motor bearings, which  
should be replaced to prevent a complete motor failure. Make sure motor mount bolts are tight.  
4. Motor bearings should be lubricated periodically, depending on operating conditions. Under normal  
usage it is desirable to have the motor cleaned, checked and bearings repacked by an authorized  
service station every two to three seasons. If the unit is operated continuously through most of the  
year, this service should be performed each year.  
NOTE: If on site bearing relubrication is to be performed, see lubrication instructions for ball bearing  
motors. To keep motor bearings properly lubricated and dispel any accumulation of moisture within  
the windings, the fan and auger motors should be operated for 15 to 30 minutes each month.  
Lubrication Instructions for Ball Bearing Motors  
Suggested Lubrication Intervals*  
Hours of Service per Year  
H. P. Range  
1/8 to 7-1/2  
10 to 40  
Suggested Lube Interval  
5 years  
3 years  
1 years  
1 year  
5000  
50 to 150  
1/8 to 7-1/2  
10 to 40  
Continuous Normal Applications  
3 year  
50 to 150  
9 months  
Seasonal Service (motor is idle for  
6 months or more)  
All  
1 year-Beginning of season  
6 months  
Continuous high ambient  
temperatures, dirty or moist  
locations, high vibrations or when  
shaft end gets hot  
1/8 to 40  
50 to 150  
3 months  
* The bearings have been lubricated at the factory, thus no lubrication should be added before start up.  
34  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
7. Service  
Suggested Lubricants  
Insulation Class  
A and B  
Consistency  
Type  
Grease  
Frame Type  
Medium  
Medium  
Medium  
Polyurea  
Polyurea  
Polyurea  
Shell Dolium R 215T and Smaller  
A and B  
Shell Dolium R  
Shell Dolium R  
254 and Larger  
All  
F and H  
NOTE: All of the auger and metering roll bearings are lifetime lubricated and do not require  
service relubrication.  
Lubrication Procedures  
If the motor is equipped with an alemite fitting, clean the tip of the fitting and apply grease with a grease  
gun. Use 1 or 2 full strokes on motors in NEMA 215 frame and smaller. Use 2 to 3 strokes on NEMA 254  
through NEMA 365 frame. Use 3 to 4 strokes on NEMA 404 frames and larger. On motors having drain  
plugs, remove drain plug and operate motor for 20 minutes before replacing drain plug. On motors  
equipped with slotted head grease screw, remove screw and apply grease tube to hole. Insert 2" to 3"  
length of grease string into each hole on motors in NEMA 215 frame and smaller. Insert 3" to 5" length on  
larger motors. On motors having grease drain plugs, remove plug and operate motor for 20 minutes before  
replacing drain plug.  
Suggested Lubricants  
Insulation Class  
A and B  
Consistency  
Medium  
Type  
Grease  
Frame Type  
215T and Smaller  
254 and Larger  
All  
Polyurea  
Polyurea  
Polyurea  
Shell Dolium R  
Shell Dolium R  
Shell Dolium R  
A and B  
Medium  
F and H  
Medium  
NOTE: All of the auger and metering roll bearings are lifetime lubricated and do not require  
service relubrication.  
Additional Checks  
1. Remove and clean the gas line strainers. Make certain gas valves are closed and that gas is purged  
from the system before attempting disassembly.  
2. If required, inspect ignitor plug and clean the electrodes. Use an ignition point file to remove  
carbon and rust between the electrode surfaces. Ignitor gap should be about 1/8''.  
3. Inspect flame sensor for possible damage or poor connections. Flame sensor wire must be in  
good condition.  
4. Inspect and manually rotate the top auger paddle assembly. The paddle unit must rotate freely  
without any indication of sticking or binding.  
5. Inspect the top auger and bottom auger drive lines for proper adjustment and condition.  
Readjust line tension as required.  
PNEG-552 100 Series Dryer  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
7. Service  
6. Operate dryer clean-out levers, and check clean-out hatch mechanism for proper operation. With  
hatch open, inspect and remove any accumulation of dirt, fines and foreign material from the  
bottom auger through area.  
NOTE: Do not allow high moisture material to collect within the trough area. It may adversely affect  
metal parts.  
1
3
4
2
Figure 7A  
7. Remove the blue burn optimizer cone and inspect:  
Ref #  
Description  
1
Inspect the collector plate (at the top of the burner casting) and the burner cup for any  
accumulation of foreign material. Clean if required. Foreign material in the burner cup or  
casting will not burn out and will impair burner operation.  
2
3
4
Burner Cup  
Ignitor Plug and Electrodes  
Flame Sensor on the Heater  
8. Inspect entire dryer for loose, worn or damaged parts. Include check of auger flighting, metering  
rolls and other internal parts. Ensure that temperature sensors in air plenum chamber are secured  
by insulated clamps, and do not chafe on other metal parts.  
9. Make sure all dryer guards and warning decals are securely installed. Guards should not  
interfere with moving parts. If guards or warning decals are missing, contact your dealer for a  
free replacement.  
10.Test fire the dryer several weeks ahead of the drying season. Check for possible gas leaks.  
(See page 25 for heater test fire.)  
36  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Service  
Fan Propeller Removal and Installation  
The fan propeller is secured to the motor shaft by the use of a taper-lock bushing, motor shaft key and  
three cap screws.  
Although the taper-lock method of retaining the propeller onto the motor shaft is  
simple, it is essential that the following points be read carefully and fully  
understood. Improper installation can cause a loose flying propeller, and result in  
serious injury or death.  
Threaded Bushing Holes  
The threaded holes within the bushing are provided for disassembly purposes only. Do not attempt to  
use these holes for reassembly. They do not allow the parts to lock onto the shaft and thereby create a  
very hazardous operating condition.  
Clearance Holes  
When reassembling parts, the cap screws must be installed through the untapped clearance holes as  
shown. This will cause the propeller to be pulled forward onto the tapered bushing, thus locking the parts  
securely onto the motor shaft. (See Figure 7B.)  
When fan servicing requires removal and installation of the propeller, make sure the propeller is  
removed and reinstalled properly.  
1. Lock out the fan power supply, remove the fan guard and the venturi, as required on some models.  
2. Remove the three cap screws from the clearance holes in the taper-lock bushing.  
Capscrews installed  
through threaded  
holes of bushing  
Key  
Fan hub  
Split taper bushing  
Figure 7B Fan Blade Installation  
PNEG-552 100 Series Dryer  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
7. Service  
Capscrews installed  
through threaded  
holes of bushing  
Fan hub  
Split taper bushing  
Figure 7C Fan Blade Removal  
3. Install two grade 5 cap screws into the threaded holes in bushing and turn them by hand until they  
bottom against the front surface of the propeller.  
4. Block propeller to prevent it from turning and gradually turn the cap screws (up to 1/4 turn at a time)  
until the propeller breaks loose from the bushing and motor shaft. Carefully remove bushing and  
propeller. With the propeller free from the bushing, a gear puller can be used to pull the bushing off  
of the motor shaft. Reattach bushing onto propeller to prevent the loss of parts.  
NOTE: During manufacture the propeller and bushing on the 26" and 28" solid aluminum blades are  
balanced together and are marked with two small dots to identify their original alignment position.  
Check the bushing and propeller to make sure they have alignment marks. Mark the alignment  
of the propeller and bushing, if necessary.  
On Crowley blades (a composite plastic), the propeller and bushing have a keyway that prevents  
any misalignment of the two pieces. There are alignment marks on the back of the fan hub  
assembly. If the user were to replace one of the blade fins, alignment would be necessary.  
However, this is not recommended. In most cases, the complete propeller should be changed.  
Fan Motor Removal and Installation  
In the event of motor failure, remove the motor as described, and take it to the nearest service station.  
An authorized service station is the only place that can provide possible motor warranty. Motor service  
and repair at other places will be at owner’s expense.  
If the service station determines motor failure is caused by faulty material or workmanship within the  
warranty period, repair will be covered under the warranty. Motor failure caused by external sources will  
result in a charge to the owner for repair.  
1. Make certain power is shut OFF and locked out. Remove fan guard and propeller. (See Figure 7D.)  
2. Remove cover from fan heater control box, and disconnect the motor lead wires within the box.  
NOTE: Tag or otherwise identify wires for ease of reassembly.  
38  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7. Service  
Figure 7D Position of Fan Motor  
3. Remove motor mount bolts. If there are shims between the motor and its base, note their location  
so they can be properly installed during reassembly.  
4. Disconnect the upper end of the motor conduit, then carefully pull the wires through the hole in the  
fan heater housing. Remove motor from the fan heater unit with the conduit still attached. If motor  
requires service, take it to an authorized service station.  
5. To reinstall motor, slide onto motor base plate and replace shims (if required) between motor base  
and plate. Reinstall motor mount bolts and washer, but do not fully tighten at this time.  
6. Reinstall conduit and wires through hole in fan heater housing and carefully connect all electrical wiring.  
7. Adjust position of motor by temporarily mounting fan blade on motor shaft. Rotate fan blade by  
hand, making the necessary adjustments, so the tip clearance between blade and housing is  
uniform. If required, remove the fan blade and fully tighten all four motor mount bolts.  
NOTE: Make sure to install and tighten the propeller in accordance with previous instructions.  
PNEG-552 100 Series Dryer  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7. Service  
Heater Parts Removal and Installation  
Most of the heater parts can be removed by identifying attached wiring and disconnecting the obvious  
mounting parts.  
1. Flame sensor: Disconnect the wire connector and unscrew the flame sensor out of its mounting  
bracket. (See Figure 7E.) IMPORTANT: Flame sensor has voltage present. Turn OFF main  
disconnect before removing or adjusting.  
2. Gas solenoid valve coil: Unsnap either the plastic cap or the metal clip on the gas valve and slide  
the housing and coil off the valve stem and body. Do not energize the coil when it is removed, as  
the coil may become damaged due to excessive current flow. (See Figure 7E.)  
3. Regulator and gas solenoid valve(s): The gas regulator and solenoid valve(s) are directional  
and must be connected as indicated by the markings near the port openings. Make sure gas is shut  
OFF and purged from the system before removing parts. (See Figure 7E.)  
NOTE: When installing a liquid gas solenoid valve on LP models, do not overtighten the connection  
into the inlet side, as the inlet orifice may become partially blocked.  
Figure 7E  
4. Main Gas Orifice: With fuel shut OFF and gas purged from system (See Figure 7E), proceed  
as follows:  
a. Disconnect the plumbing support brackets from the pipetrain.  
b. Disconnect gas solenoid valve coils. Be sure to mark which one goes where.  
c. Lift pipe (with orifice, solenoid valve and other parts attached) straight up and remove from fan  
heater housing. Orifice and other parts can now be removed from pipe train, if desired.  
40  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
7. Service  
5. Reassemble: To reassemble parts (See Figure 7E), reverse the disassembly procedure and check  
the following:  
a. Make sure all parts are thoroughly cleaned and open.  
b. Use a dependable brand of high temperature pipe caulking compound when assembling gas  
connections. Apply only a light coating onto male threaded end of fittings.  
c. Solenoid valves and gas regulators are directional and must be properly installed. Do not  
attempt to connect gas solenoid valve by applying force to the valve core stem as it may ruin  
the unit.  
d. Make sure all electrical wires are properly connected. Refer to Wiring Diagrams.  
Figure 7E shows:  
1 - Gas Solenoid Valve Coils  
2 - Gas Regulator  
3 - Gas Solenoid Valves  
Metering Roll Servicing  
Figure 7F Meter Roll Motor and Speed Reducer Gear Box for the Metering Rolls.  
This dryer is equipped with SCR (silicon controlled rectifier) metering roll drive assembly. The metering  
rolls are driven by a separate DC type electric motor. The speed of the motor is variable and is controlled  
by an electric SCR control within the main control box. (See Figure 7F.)  
Main Controls  
1. SCR speed control: The control unit dial on the front of the control box regulates the speed of the  
DC motor which drives the metering rolls. (See Figure 7F.)  
The markings on the scale from 0 to 999 represent the flow of grain past the metering rolls as a  
percent of the maximum grain discharge rate for the dryer. The maximum setting of 999 provides  
a maximum 100% discharge of 857 BPH for 190T, 1285 BPH for 270, 1499 BPH for 320, 1714  
BPH for 370,1928 BPH for 400, 2142 BPH for 460, 2356 BPH for 511 and 2785 BPH for 601  
model dryers.  
NOTE: When the control is set to the maximum discharge rate (999), the metering roll speed should  
be 17.5 RPM.  
PNEG-552 100 Series Dryer  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
7. Service  
2. DC electric motor: The direct current (DC) motor provides the drive for the metering roll and is  
located on the front left hand side of standard model dryers. The output shaft of the motor is  
connected directly to the gear box assembly. (See Figure 7F.)  
The DC motor requires no operational adjustment as it is completely controlled from the control box.  
3. Speed reducer gear box: The direct drive gear box provides the required speed reduction,  
and transmits power to the metering rolls through a drive chain arrangement. The gear box does  
not require adjustment. The drive chain should also be periodically lubricated and tensioned  
as necessary. (See Figure 7F.)  
4. Unload auger time delay: The delay controls the bottom auger system and causes the unload  
auger (and any connected auxiliary unloading conveyors) to continue operating for the  
programmed amount of time, even after the metering rolls stop. (See Figure 7F.)  
This feature permits the clean-out of grain within the unloading equipment at the end of all  
discharge cycles.  
How to Determine a Metering Roll Problem  
Figure 7G Metering Roll Drive  
To determine if the metering problem is from blockage, perform the following test with the power OFF.  
Remove the drive chain by loosening the motor mounting bolts. Refer to Figure 7G, and place a pipe  
wrench on the hub of the roller chain sprocket, on the left hand metering roll at the drive end of the dryer.  
Apply up to 100 ft. lbs. of force, and try to rotate the roll towards the inside of the dryer. If the metering  
roll turns, then repeat for right hand side and it can be assumed that no blockage exists, and the problem  
is from some other cause. Check for a break in the power train, chain, drive key, pin, etc.  
Keep hands away from sprocket teeth to avoid injury from chain backlash, as a  
result of torsion build up in the system caused by the jam.  
42  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
7. Service  
How to Clear a Jammed Metering Roll  
Shut down the fan/heater and eliminate any other noise when making this check. Place a pipe wrench  
on the hub of the sprocket of the jammed metering roll and turn the roll. First backward, and then forward  
several times in an attempt to dislodge the object, and clear it through the roll. If this is not successful,  
have an assistant turn the metering roll, and attempt to locate the jam by sound. Once the location is  
determined, the roll can be reached from the inside of the dryer by opening the hinged auger cover panel  
in that specific section. Loosen the two (2) nuts on the bolts holding the meter roll shield (also called  
meter roll strike off Plate in the past) and lift the shield to access the area above and behind the meter  
roll. If removing all the grain from this column is necessary, lift the shield to its highest position and  
tighten the nuts. FROM OUTSIDE THE DRYER, manually run the Unload Auger with the MOISTURE  
CONTROL switch turned OFF and the high speed potentiometer set to 000. This will allow the grain from  
that column alone to pass over the metering roll and into the auger emptying that column for complete  
access to the meter roll.  
Never run the unload auger or the metering rolls with anyone inside the dryer.  
PNEG-552 100 Series Dryer  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. Wiring Diagrams  
100 Series Single Fan Wiring to Control Box  
44  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
8. Wiring Diagrams  
100 Series Front Panel External Wiring  
PNEG-552 100 Series Dryer  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. Wiring Diagrams  
100 Series Front Panel Internal Wiring  
46  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. Wiring Diagrams  
100 Series Lower Back Panel Wiring  
PNEG-552 100 Series Dryer  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. Wiring Diagrams  
100 Series External Wiring to Dryer  
48  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. Wiring Diagrams  
100 Series Upper Control Box Wiring  
PNEG-552 100 Series Dryer  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. Wiring Diagrams  
100 Series Main Power Wiring  
50  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
9. Schematic Diagram  
100 Series Control Schematic  
PNEG-552 100 Series Dryer  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
9. Schematic Diagram  
100 Series Control Schematic (Continued)  
52  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. Schematic Diagram  
100 Series Control Schematic (Continued)  
PNEG-552 100 Series Dryer  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. Schematic Diagram  
100 Series 220 Volt 1 Phase Power Schematic  
54  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
9. Schematic Diagram  
100 Series 220VAC 3 Phase Power Schematic  
PNEG-552 100 Series Dryer  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
9. Schematic Diagram  
100 Series 440VAC 3 Phase Power Schematic  
56  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
10. Troubleshooting  
A multimeter is required for some of the following checkout procedures. Before performing any tests,  
determine if the dryer power supply is 1 phase, 230 volt, or 3 phase, 230 or 460 volt.  
• The burner circuit is 120 volts AC on all standard U. S. production models.  
• The control circuit to the motor starters is 120 volts AC.  
• The safety circuit is 12 volts DC.  
• When checking these circuits, measure voltage between the circuit test location and to ground.  
• DC circuits should be measured between the test location and its respective DC ground. Refer to  
Wiring Diagrams and the parts list for identification of parts and the electrical terminals.  
When making high voltage tests with “live” circuits, be extremely careful.  
Follow established safety practices. Turn power ON for testing only. Do not  
attempt to make the dryer operate by using a jumper wire to bypass a defective  
safety component.  
Problem  
Control power light OFF.  
Possible Cause  
1. Check that main power and circuit breakers are turned ON.  
Check for tripped breaker.  
2. Check for blown 5 amp fuses.  
3. Monitor relay is defective.  
4. Defective transformer or wiring.  
5. Check for a defective power switch.  
6. Check wiring between fuses and input/output board. Refer to  
Wiring Diagrams for test locations.  
Control power is ON. Drying mode light OFF.  
1. Power interruption: Incoming power to the dryer has been  
interrupted. The display screen will show the date and time if this  
has occurred, once power has returned.  
This indicates control power is present at  
input/output board, but no power is being  
transferred through the I/O board.  
2. Display not finished initial setup: The monitor will display a  
copyright message and model number, total running time in  
hours and minutes and then the current date and time. To  
activate the controller press the reset button.  
3. Input/output board: The input/output board has developed a  
problem that requires its replacement.  
No display on LCD screen.  
1. Check for a defective power switch.  
2. Check wiring between fuses and input/output board.  
3. Check for 120 volts AC between points J6-02 and AC-1.  
4. The display may have a malfunction requiring its replacement.  
1. Press the dryer power start button.  
Control power light is ON, drying mode light is  
ON-load auger, fan, heater, unload auger does not  
operate.  
2. Refer to the problem listed for load auger, fan heater and unload  
auger in the following sections.  
Display shows “MOTOR OVERLOAD” message.  
The thermal overload on the fan motor, load motor, unload motor or  
an auxiliary motor has opened indicating an overloaded motor.  
(The overloads must be manually reset.)  
Display shows “VAPOR HIGH TEMPERATURE”  
message.  
The LP gas vapor temperature sensor located in the gas train  
downstream from the vaporizer has opened, indicating that the  
vaporizer is running too hot and must be readjusted. (This control  
is a 200°F limit which automatically resets when it cools.)  
Display shows “LOSS OF FLAME” message.  
The flame sensor has failed to detect a burner flame, indicating  
that the burner has failed to light. There is a problem with the flame  
sensing circuitry or the dryer is not getting burner fuel.  
PNEG-552 100 Series Dryer  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
10. Troubleshooting  
Problem  
Possible Cause  
Display shows “HOUSING HIGH TEMPERATURE”  
message.  
The temperature high-limit located on the fan/burner housing has  
opened, indicating an over temperature condition has occurred  
towards the rear of the fan/heater housing. (This control is a 200°F  
limit control that must be manually reset.)  
Display shows “REAR DISCHARGE WARNING”  
message.  
The cover on the grain discharge box has opened, indicating that  
grain is backing up into the discharge box.  
Display shows “OUT OF GRAIN” message.  
The dryer has run low on grain, and the out of grain timer has timed  
out shutting the dryer down. The unload auger will then clean-out  
the dryer, if the unload switch is ON during continuous flow  
operation. Check the out of grain timer setting, and if necessary  
adjust. Also, before restarting, inspect load equipment for possible  
damage or adjustment.  
Display shows “PLENUM HIGH TEMPERATURE”  
message.  
An over temperature condition has occurred inside the dryer  
Plenum. (This control is a 300°F limit which automatically resets  
when it cools.)  
Display shows “NO AIRFLOW” message.  
The air switch contacts have opened, indicating the fan may not be  
turning. The air switch may need adjustment.  
Display shows “Grain High Temperature” message  
An over temperature condition has occurred in the Dryer Grain  
Columns. This control is a 200°F limit which automatically resets  
when it cools. It may require the use of the Emergency Cool  
Feature as described on Page 18.  
Display shows “Grain High Temperature” and  
Plenum High Temperature” messages at the  
same time  
One of both of the mechanical high-limits located one in each grain  
column have tripped. Note that the Emergency Cooling  
Feature will not work in this case, open the back access door to  
help speed the cooling of the grain. Replace the mechanical  
sensor if faulty.  
Fan motor does not start.  
1. Check that the fan circuit breaker and the FAN switch are ON.  
Also, check for defective switch or bad wiring connections.  
2. If lighted switch does not light, the air switch needs adjustment,  
or the bulb may be burned out.  
3. Verify closing of fan motor contactor. Check voltage on load side  
of contactor. See appropriate power Wiring Diagrams for  
terminal numbers. Inspect contactor for defective points or a  
burned out coil.  
4. Inspect connections, and check voltage applied to the  
motor leads in the fan heater box to determine if the motor  
is defective.  
5. Check capacitors on single phase motors, and replace if  
defective. If motor starts slowly, check for low voltage during  
starting due to excessive voltage drop in power supply wiring.  
Top auger does not start.  
1. Check that the top auger circuit breaker and the load auger  
switch are turned ON.  
2. If lighted switch does not light, the output power to the contactor  
is missing. Check connections, or if the bulb is burned out.  
3. Check position of the upper auger paddle switch. It must be  
down to start auger.  
4. Inspect for secure mounting and wiring of mercury switch in the  
terminal box on the top auger paddle switch shaft. Include check  
for a defective mercury switch.  
5. Verify closing of the top auger contactor. Check voltage on load  
side of contactor. Inspect contactor for defective points, or a  
burned out coil.  
6. Inspect connections, and check voltage applied to motor leads in  
motor junction box to determine if motor is defective.  
7. Check that the mercury switch box is in the proper position.  
58  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. Troubleshooting  
Problem  
Possible Cause  
Bottom auger does not start.  
1. Check that the bottom auger circuit breaker is ON.  
2. If the lighted switch does not light, the output power to the  
contactor is missing. Check connections, and whether the bulb  
is burned out.  
3. Check that the unload switch is ON (1 Speed or 2 Speed).  
4. Verify closing of bottom auger contactor; check voltage on load  
side of contactor.  
5. If using the moisture control, check for proper setting, or  
defective operation of the control.  
6. Check for any loose wire connections in unload auger and  
moisture control thermostat circuits.  
Grain not moving through columns.  
1. Check the dryer for fine material buildup inside the columns.  
2. Avoid leaving the dryer columns full for long periods at a time  
(2-3 days) while not operating the dryer or during rainy weather.  
3. Empty the dryer. Keep the dryer clean. Do not allow fine material  
to gather in the plenum chamber.  
4. It may be necessary to open the strike off plates in the affected  
columns in half inch intervals.  
Uneven drying-Some kernels appear brown while  
others are under dried.  
1. Check plenum thermostat temperature setting. Some varieties of  
grain are more sensitive to higher operating temperatures. It  
may be necessary to lower the plenum operating temperature to  
accommodate this.  
Uneven heat exiting from dryer columns.  
Burner does not fire with fan operating.  
2. Check for proper burner alignment (side to side). Vibration  
during shipment may have caused misalignment.  
1. Burner switch must be ON.  
2. Check for power to ignition board.  
Heater light and gas solenoids go ON and OFF  
erratically. The light blinks ON and OFF while the  
solenoids “chatter”.  
1. The blinking light indicates the flame sensor is not  
detecting flame.  
2. The “chattering” solenoids are caused by the loss of flame  
detection and the thermostat, and Fenwal Ignition Board trying  
to reestablish a flame. Check for loose wires on flame sensor;  
replace or repair wires or sensor.  
Burner does not fire. No gas pressure with fan  
operating at least 15 seconds (gas supply or fan  
heater malfunction).  
1. Check gas supply. Also, check gas filter and gas line for possible  
obstruction or closed valves. Refill tank; replace or repair parts,  
as required.  
2. Inspect gas solenoid valves (including liquid valve on LP units)  
for defective coils or improper wiring. Replace valve or coil if  
valve will not open with proper voltage applied (115 volts).  
3. Check for proper voltage. 115 volts across L1 and L2 incoming  
voltage to the Fenwal Ignition Board and 115 volts outgoing  
across V1 and V2 to the solenoids.  
Burner does not fire but gauge shows gas pressure.  
1. Fenwal Ignition Board: Check board for spark by removing  
ignition wire from board, and holding an insulated screwdriver  
against the output terminal and 1/4" away from the control box  
casing. There should be a strong spark. Check board wire  
connections. Replace the Fenwal Board, if necessary.  
2. Ignitor: Check that the ignitor is properly gapped to 1/8" and that  
it has a strong spark. Inspect the porcelain and electrodes for  
damage or cracking. Replace or clean if necessary.  
Burner maintains desired drying temperature-but  
cycles from high-fire to OFF (without going to  
low-fire).  
1. Make sure the low flow control valve is not completely closed.  
Valve must be adjusted open to provide the proper low-fire gas  
pressure listed in this manual.  
2. Check low-fire solenoid valve for proper operation.  
PNEG-552 100 Series Dryer  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. Troubleshooting  
Problem  
Possible Cause  
Burner operates but does not cycle from high-fire to  
low-fire.  
1. Check the gas pressure reading on the gauge. Problem may be  
due to insufficient gas regulator setting. Temporarily decrease  
the High-Low Fire thermostat setting to verify that the  
thermostat will function and cause the burner to cycle. If burner  
will cycle at the reduced thermostat setting, it indicates that the  
problem was due to insufficient heat to satisfy the original  
setting. Increase the gas regulator setting for additional  
heat output. Do not exceed the maximum pressure listed in  
this manual.  
2. High-Low Fire thermostat control may be defective. If the burner  
still does not cycle to low-fire after decreasing the thermostat,  
the problem may be due to a broken or kinked thermostat  
sensor tube. Observe reading on the thermometer. Replace  
control assembly if it cannot be set to cause its switch to go  
to the open circuit position with normally hot air plenum  
temperatures.  
3. If the burner continues to operate on high-fire, check the  
high-fire gas solenoid valve for a stuck or blocked open  
condition, or for reversed gas pipe connections. The solenoid  
valve must not allow gas flow when its coil is not energized.  
Burner operates but does not cycle from low-fire  
to high-fire.  
1. Check for an excessive low-fire gas pressure setting. Observe  
pressure setting shown on gauge, and compare reading with  
recommended low pressure settings listed in this manual.  
Readjust low-fire setting on flow control valve, if necessary.  
2. Check for improperly adjusted or defective High-Low Fire  
thermostat control. Temporarily increase the temperature  
setting. If the heater will still not cycle, check for problem in the  
control wire connections. The control wires should be connected  
to terminals R and B of the thermostat, so the switch will open  
upon temperature rise. If the burner will cycle with these two  
wires connected together, the thermostat is faulty.  
3. Check for improperly connected or faulty high-fire gas vapor  
solenoid valve. Correct any poor connections or defective  
wiring. If wiring appears proper, problem may be caused by a  
burned out valve coil or defective valve. Replace high-fire  
solenoid valve, or its coil, if defective.  
If the Load and Unload Auger does not start but  
everything else seems to work.  
Check the fuse on the I/O Board in the back of the lower  
control Box.  
60  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11. FAQs  
How much gas pressure is needed?  
See Step 4 on Page 31 in the Adjusting the Temperature section.  
How often should the burner cycle?  
See Step 5 on Page 31 in the Adjusting the Temperature section.  
How often do I make speed adjustments?  
See Step 4 on Page 33 in the Adjusting the Moisture Control section.  
How do I set the moisture control?  
See Step 1 on Page 33 in the Adjusting the Moisture Control Section.  
PNEG-552 100 Series Dryer  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
NOTES  
62  
PNEG-552 100 Series Dryer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12. Warranty  
The GSI Group Warranty  
THE GSI GROUP (GSI) WARRANTS ALL PRODUCTS WHICH IT MANUFACTURES TO BE FREE OF  
DEFECTS IN MATERIAL AND WORKMANSHIP UNDER NORMAL USAGE AND CONDITIONS FOR  
A PERIOD OF 12 MONTHS AFTER RETAIL SALE TO THE ORIGINAL END USER. THE  
PURCHASER’S SOLE REMEDY AND GSI’S ONLY OBLIGATION SHALL BE TO REPAIR OR  
REPLACE, AT GSI’S OPTION AND EXPENSE, PRODUCTS THAT, IN GSI’S SOLE JUDGMENT,  
CONTAIN A MATERIAL DEFECT DUE TO MATERIALS OR WORKMANSHIP. ALL DELIVERY AND  
SHIPMENT CHARGES TO AND FROM GSI’S FACTORY WILL BE PURCHASER’S RESPONSIBILITY.  
EXPENSES INCURRED BY OR ON BEHALF OF THE PURCHASER WITHOUT PRIOR WRITTEN  
AUTHORIZATION FROM AN AUTHORIZED EMPLOYEE OF GSI SHALL BE THE SOLE  
RESPONSIBILITY OF THE PURCHASER.  
EXCEPT FOR THE LIMITED WARRANTY EXPRESSED ABOVE, GSI MAKES NO FURTHER  
WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION,  
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE IN  
CONNECTION WITH (I) PRODUCT MANUFACTURED OR SOLD BY GSI OR (II) ANY ADVICE,  
INSTRUCTION, RECOMMENDATION OR SUGGESTION PROVIDED BY AN AGENT,  
REPRESENTATIVE OR EMPLOYEE OF GSI REGARDING OR RELATED TO THE CONFIGURATION,  
INSTALLATION, LAYOUT, SUITABILITY FOR A PARTICULAR PURPOSE, OR DESIGN OF  
SUCH PRODUCTS.  
GSI SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL  
DAMAGES, INCLUDING, WITHOUT LIMITATION, LOSS OF ANTICIPATED PROFITS OR BENEFITS.  
PURCHASER’S SOLE AND EXCLUSIVE REMEDY IS AS SET FORTH IN THE LIMITED WARRANTY  
EXPRESSED ABOVE, WHICH SHALL NOT EXCEED THE AMOUNT PAID FOR THE PRODUCT  
PURCHASED. THIS WARRANTY IS NOT TRANSFERABLE AND APPLIES ONLY TO THE ORIGINAL  
PURCHASER. GSI SHALL HAVE NO OBLIGATION OR RESPONSIBILITY FOR ANY  
REPRESENTATIONS OR WARRANTIES MADE BY OR ON BEHALF OF ANY DEALER, AGENT OR  
DISTRIBUTOR OF GSI.  
GSI ASSUMES NO RESPONSIBILITY FOR CLAIMS RESULTING FROM ERECTION DEFECTS OR  
UNAUTHORIZED MODIFICATIONS TO PRODUCTS WHICH IT MANUFACTURED. MODIFICATIONS  
TO PRODUCTS NOT SPECIFICALLY DELINEATED IN THE MANUAL ACCOMPANYING THE  
EQUIPMENT AT INITIAL SALE WILL NULLIFY THE PRODUCT WARRANTY THAT MIGHT HAVE  
BEEN OTHERWISE AVAILABLE.  
THE FOREGOING WARRANTY SHALL NOT EXTEND TO PRODUCTS OR PARTS WHICH HAVE  
BEEN DAMAGED BY NEGLIGENT USE, MISUSE, ALTERATION OR ACCIDENT. THIS WARRANTY  
EXTENDS SOLELY TO ONLY PRODUCTS MANUFACTURED BY GSI. THIS WARRANTY IS  
EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED. GSI RESERVES  
THE RIGHT TO MAKE DESIGN OR SPECIFICATION CHANGES AT ANY TIME.  
PRIOR TO INSTALLATION, PURCHASER HAS THE RESPONSIBILITY TO COMPLY WITH ALL  
FEDERAL, STATE AND LOCAL CODES WHICH MAY APPLY TO THE LOCATION AND  
INSTALLATION OF PRODUCTS MANUFACTURED OR SOLD BY GSI.  
PHLEGAL: #1832020 v1 (139LG01!.DOC)  
(revised December 2005)  
PNEG-552 100 Series Dryer  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
This equipment shall be installed in accordance with  
the current installation codes and applicable  
regulations which should be carefully followed in all  
cases. Authorities having jurisdiction should be  
consulted before installations are made.  
GSI Group  
1004 E. Illinois St.  
Assumption, IL 62510-0020  
Phone: 1-217-226-4421  
Fax: 1-217-226-4420  
Copyright © 2007 by GSI Group  
Printed in the USA  
Download from Www.Somanuals.com. All Manuals Search And Download.  

H2O Audio Headphones 20081201 User Manual
Haier Freezer BD 60G User Manual
Healthrider Home Gym HRE69940 User Manual
Heatiator Indoor Fireplace ECO WINS18 User Manual
Hotpoint Freezer RSA 21 User Manual
Hotpoint Refrigerator RSA User Manual
HP Hewlett Packard Blu ray Player DVD600S User Manual
HP Hewlett Packard Personal Computer 733UK User Manual
HP Hewlett Packard Switch 2012i User Manual
IKEA Indoor Furnishings AA 278407 2 User Manual