2. Fasten the power output cord to the ZipClip base.
Extron External Power Supply •
a. Insert tie wraps (“zip ties”) along the notches on the side of the
Installation Guide
power supply and
through the tie wrap
anchor points on the
ZipClip, then around
the cord.
Important Safety Instructions
This symbol is intended to alert the user of impor-
tant operating and maintenance (servicing) instruc-
tions in the literature provided with the equipment.
WARNING: To reduce the risk of fire or electric shock, do not
expose this apparatus to rain or moisture.
This apparatus shall not be exposed to dripping or splashing
and no objects filled with liquids, such as vases shall be
placed on the apparatus.
Cable
Strain
Relief
b. Connect and pull the
This symbol is intended to alert the user of the
presence of uninsulated dangerous voltage within
the product enclosure that may present a risk of
electric shock. On the product, risk of shock may
be indicated by this symbol.
tie wraps until they
Tie Wrap
Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as
when the power-supply cord or plug is damaged, liquid has
been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.
are secure. Do not
over tighten.
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Mounting
WARNING: This apparatus is a Class I product. This product
must be connected to a MAINS socket outlet with a
protective earthing connection.
Do not use this apparatus near water.
Clean only with dry cloth.
Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
CAUTION: These power supplies are not suitable for use in air handling
spaces or in wall cavities. The power supply is to be located within
the vicinity of the Extron AV equipment in an ordinary location
with IEC 1010 pollution degree 2, and secured to an equipment rack
within a dedicated closet, podium, or desk.
The mains plug is used as the disconnect device and shall remain
readily operable.
Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat.
To prevent the risk of shock, do not attempt to service this
equipment yourself because opening or removing covers may
expose you to dangerous voltage or other hazards.
Do not defeat the safety purpose of the polarized or grounding-type
plug. A polarized plug has two blades with one wider than
the other. A grounding type plug has two blades and a third
grounding prong. The wide blade or the third prong are provided
for your safety. If the provided plug does not fit into your outlet,
consult an electrician for replacement of the obsolete outlet.
WARNING:
Power sources • This equipment should be operated only from
the power source indicated on the product. This equipment
is intended to be used with a main power system with a
grounded (neutral) conductor. The third (grounding) pin is
a safety feature, do not attempt to bypass or disable it.
The installation must be in accordance with the applicable provisions
of National Electrical Code ANSI/NFPA 70, article 75 and Canadian
Electrical Code part 1, section 16. The power supply shall not be
permanently fixed to building or similar structure.
Protect the power cord from being walked on or pinched particularly at
plugs, convenience receptacles, and the point where they exit from
the apparatus.
Only use attachments/accessories specified by the manufacturer.
Power disconnection • To remove power from the equipment
safely, remove all power cords from the rear of the
equipment, or the desktop power module (if detachable), or
from the power source receptacle (wall plug).
Unplug this device apparatus during lightning storms or when
unused for long periods of time.
Rack Mounting
Mounting to a Rack Shelf
About the Extron PS 910, PS 1210, PS 1508
Power Supplies
These power supplies are one eighth rack wide. Up to eight power supplies
can be mounted side by side directly onto a rack shelf.
1. Align the threaded holes in the bottom of the power supply with the
Model Overview
holes in an Extron rack
shelf and fasten the
supply to the shelf
with two 4-40 x 3/16"
screws as shown
below.
Model
Power Output
9 watts, 9 VDC, 1 A
9 watts, 9 VDC, 1 A
12 watts, 12 VDC, 1 A
12 watts, 12 VDC, 1 A
12 watts, 15 VDC, 0.8 A
—
Termination
Captive screw
DC plug
PS 910C
PS 910P
PS 1210C
PS 1210P
PS 1508C
Captive screw
DC plug
Captive screw
—
ZipClip™ 100
b
(101-002-01)
RSB 123
Rack Shelf
Cabling and Features
Features
a
(2) 4-40 x 3/16"
Screws
Notches for
Securing
Tie Wrap
AC
Power
Input
2. Bolt the rack shelf to the rack.
Power
LED
z
X
1MA
124V5-60H
Mounting to Rack Rails Using a ZipClip
ZipClip
Mounting Slot
(front and rear)
1. Fasten the ZipClip 100
mounting clip to a
rack rail using
two rack
DC Power
Output
Connector Pin Assignments
screws as
shown in the
PS 910C, PS 1210C, PS 1508C
PS 910P, PS 1210P
Tie Wrap
Smooth
diagram at
ZipClip 100
right.
Tip (+)
Power Supply
Output Cord
Captive Screw
Connector
Ridged
Sleeve (
-)
Side of Rack
Alternative Wiring Option
Smooth
2. Insert the
power supply
into the ZipClip as
described previously
and press to snap it
into place.
Power Supply
N/C
Back of
Rack
Output Cord
Ridged
Inside
Rack
Using the ZipClip 100
Attaching and Removing the Clip and Power Supply
To attach the power supply to the ZipClip 100 mounting clip:
Pole or Table Leg Mounting
1. Insert the bottom of the power supply down into the clip,
starting with one end.
1. Wrap a tie wrap around
the projector mount pole or table
leg and the power supply at one of
the tie wrap notches, and fasten the
2. Pivot the other end down and press until the clip snaps into place.
tie wrap together to secure the
power supply to the pole or table
leg.
To remove the power supply from the ZipClip:
Tie Wrap
to Pole
b
1. Press the tab on the ZipClip.
2. Pivot the power supply and lift it out
2. Repeat step 1 at the other tie wrap
of the ZipClip.
notch.
Using Tie Wraps for Cable Strain Relief
1. Attach the power supply to the ZipClip mounting clip as described
See the next page for
furniture mounting instructions.
previously.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
|