| 353AAV Plus 90x   4--Way Multipoise Condensing Gas Furnace   Input Rates: 40,000 Only   Product Data   the furnace resulting in lower electrical usage. The high   efficiency achieved by superior heat transfer is made only   better—by optimizing the efficient ECM motor speed tap   locations.   4--WAY MULTIPOISE DESIGN ALLOWS   MORE APPLICATIONS   A standard media filter cabinet accessory is provided with the   Plus 90x in order to provide an opportunity to enhance indoor air   quality. As with all other Bryant furnaces, this model is designed   to work as a part of the total home comfort system which includes   elements for cooling, air cleaning, humidification, ventilation and   zoning. Boosting the unit’s efficiency with the ECM motor and   Bryant’s deluxe features show the Plus 90x has been designed   with the homeowner in mind.   PLUS 90X FEATURES & BENEFITS   TM   Everlastic   — Exclusive Everlastic coating,   a patented   polypropylene laminate is used on the secondary heat exchanger   and greatly reduces maintenance.   Perfect Light™ Igniter — Bryant’s unique Perfect Light™   igniter is not only physically robust but it is also electrically   robust. It is capable of running at line voltage and does not   require complex voltage regulators as do other brands. This   unique feature further enhances the reliability of the Plus 90x gas   furnace and continues Bryant’s tradition of technology leadership   and innovation in providing a reliable and durable product.   FanOn™ — Improves comfort all year long by allowing the   homeowner to select different fan speeds during continuous fan   operation to achieve more or less airflow. This is done right at the   thermostat.   A05085   A UNIQUE SEER SOLUTION   The Plus 90x is an exciting addition to your product line. This   high--efficiency 4--way multipoise design furnace allows more   applications while the ECM motor and Bryant’s control logic   combine to provide a SEER increase of up to 1.5 points.*   SmartEvap™ — This feature allows your system to reduce   summertime humidity levels by nearly 10% over standard   systems.   Some of Bryant’s best--engineered components contribute to the   efficient performance of this condensing furnace. The Plus 90x   utilizes Power Lightt hot surface ignition (HSI), which ignites   the burners directly. HSI eliminates gas waste that typical   continuous--pilot designs can bring. Hot surface ignition has   proven to contribute to reliable start--up and operation of Bryant   furnaces.   Media Filter Cabinet — Enhanced indoor air quality in your   home is made easier with our media filter cabinet—a standard   accessory on all Deluxe furnaces. When installed as a part of your   system, this cabinet allows for easy and convenient addition of a   Bryant high--efficiency air filter.   Control Center — Microprocessor controls sequencing and   furnace operation. Equipped with a component test feature and   status indicator light to assist in troubleshooting. Microprocessor   controls blower times to start blower after main burners ignite to   eliminate cold air blowing into rooms.   Another deluxe feature included with this furnace is Bryant’s   trusted Everlastict secondary heat exchanger;   a patented   polypropylene laminate that provides exceptional heat transfer   and corrosion resistance. Using the exclusive flow--through   design, the secondary heat exchanger reduces the pressure drop in   *as compared to the Air---Conditioning, Heating and Refrigeration Institute’s standard coil---only rating (A/Cs up to 3.5 tons) when paired with selected Bryant   evaporator coils.   1 Download from Www.Somanuals.com. All Manuals Search And Download.   13   14   1 2 3 4 5 6 6 7 8 9 15   16   10   17   18   11   12   19   20   A08421   1. Burner sight glass for viewing burner flame.   11. Heavy--duty blower circulates air across the heat   exchangers to transfer heat into the home.   2. Burner assembly (inside), operates with energy--sav-   ing, inshot burners and hot surface igniter for safe,   dependable heating.   12. Air filter and retainer may be used for side or bottom   return application.   3. Combustion--air intake connection to ensure contam-   inant--free air (right or left side).   13. Rollout switch (manual reset) to prevent overtemper-   ature in burner area.   4. Redundant gas valve, safe, efficient, features 1 gas   control with 2 internal shutoff valves.   14. Primary serpentine heat exchanger (inside). Stretches   fuel dollars with the S--shaped heat--flow design. Sol-   id weld--free construction of corrosion--resistant alu-   minized steel means reliability.   5. Junction box for 115--v electrical power supply.   (right or left side)   15. A 3--amp fuse provides electrical and component   protection.   6. Vent outlet uses sealed PVC pipe to carry vent gases   from the furnace’s combustion system (right or left   side).   16. Light emitting diode (LED) on control center. Code   lights are for diagnosing furnace operation and ser-   vice requirements.   7. Secondary condensing heat exchanger (inside),   wrings out more heat through condensation of gases.   Constructed with polypropylene--laminated steel to   ensure durability.   17. Control center.   18. Blower access panel safety interlock switch.   8. Pressure switch ensures adequate flow of flue   products through furnace and out vent system.   19. Transformer (24v) behind control center provides   low--voltage power to furnace control center and   thermostat.   9. Inducer motor pulls hot flue gases through the heat   exchangers, maintaining negative pressure for added   safety.   20. Power choke (used with 1 HP and 3/4 HP motors.)   10. Condensate drain connection collects moisture con-   densed during the combustion process. 1 2 3 4 5 6   3 Download from Www.Somanuals.com. All Manuals Search And Download.   PHYSICAL DATA   **Note: 060--120 Sizes are phasing out.**   UNIT SIZE   036040   036060   036080   048080   060100   060120   SHIPPING WEIGHT LB. (KG)   LIMIT CONTROL   175 (47)   182 (57)   198 (64)   205 (69)   SPST   232   261 (74)   HEATING BLOWER CONTROL   (Off Delay)   Solid---State Time Operation   BURNERS (Monoport)   2 3 4 4 5 6 GAS CONNECTION SIZE   1/2---in. NPT   GAS VALVE(Redundant)   White --- Rodgers   4.5 (Natural Gas)   Manufacturer   Minimum Inlet Pressure   (in. wc)   Maximum Inlet Pressure   (in. wc)   IGNITION DEVICE   DIRECT---DRIVE MOTOR   ( E C M X --- 1 3 )   MOTOR FULL LOAD AMPS   R P M ( N o m i n a l ) --- S P E E D S   13.6 (Natural Gas)   Hot Surface   3/4   1/2   6.8   1/2   6.8   1/2   6.8   1 1 8.4   1050---5   10.9   10.9   BLOWER WHEEL DIAMETER X   W I D T H --- I N ( m m )   10 X 7   (254 X 178)   10 X 7   (254 X 178)   10 X 7   (254 X 178)   11 X 8   (279 X 203)   11 X 10   (279 X 254)   11 X 10   (279 X 254)   F I LT E R S I Z E ( W a s h a b l e ) ---   IN (mm)   (1) 16 X 25 X 3/4   (406 X 635 X 19)   (1) 20 X 25 X 3/4   (508 X 635 X 19)   (1) 24 X 25 X 3/4   (610 X 635 X 19)   Always Ask For   G F E N I D Use of the AHRI Certified TM Mark indicates a   manufacturer’s participation in the program. For   verification of certification for individual products,   C E D   CERTIFIED   E R T 4 Download from Www.Somanuals.com. All Manuals Search And Download.   BRYANT ACCESSORIES*   ACCESSORIES   GAS CONVERSION KIT ---   NATURAL TO PROPANE   GAS CONVERSION KIT ---   PROPANE TO NATURAL   MANUFACTURED (MOBILE)   HOME KIT   KGANP4601ALL   KGANP3901ALL   KGAMH0301KIT   KGASB0301ALL   DOWNFLOW BASE   (For Combustible Floors)}   VENT TERMINATION KIT   (Bracket Only for 2 Pipes)   CONCENTRIC TERMINATION   KIT (Single Exit)   CONDENSATE FREEZE   PROTECTION KIT   2---IN. ---KGAVT0101BRA 3---IN. --- KGAVT0201BRA   2---IN. ---KGAVT0701CVT 3---IN. --- KGAVT0801CVT   KGAHT01010CFP   CONDENSATE NEUTRALIZER   KIT (Obtained thru RCD)   P908---0001   ELECTRONIC AIR CLEANER   (EAC)   Model EACB   AIR PURIFIER   MECHANICAL AIR CLEANER   HUMIDIFIER   Models GAPAAXBB1625, GAPAAXBB2025   Models EZXCAB, FILCAB   Model HUM   HEAT RECOVERY VENTILATOR   Model HRV   ENERGY RECOVERY   Model ERV   Model UVL   VENTILATOR   UV LIGHTS   VENT/EXHAUST PIPE   KGAET0106ETK   KGBAC0110DGK   EXTERNAL TRAP KIT   DOOR GASKET KIT   UNFRAMED FILTER,   PERMANENT WASHABLE 3/4”   (19mm)   KGAWF1301UFR   KGAWF1401UFR   KGAWF1501UFR   16 x 25 (406 x 635 mm)   UNFRAMED FILTER,   PERMANENT WASHABLE 3/4”   (19mm)   16 x 25 (508 x 635 mm)   UNFRAMED FILTER,   PERMANENT WASHABLE 3/4”   (19mm)   16 x 25 (610 x 635 mm)   F o r u s e w i t h 1 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r --- T 6 --- N A C , T 2 --- N A C   F o r u s e w i t h 1 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r --- T 6 --- N H P --- T 2 --- N H P *   F o r u s e w i t h 2 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r --- T 6 --- N R H *   For use with multi---use / stage configurations --- deg. F/C, Auto Changeover/Temperature and   H u m i d i t y C o n t r o l --- T 6 --- P R H {   T H E R M O S TA T ---   NON---PROGRAMMABLE   F o r u s e w i t h 1 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e ---   T 6 --- PA C   F o r u s e w i t h 1 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e ---   T6---PHP*   F o r u s e w i t h 2 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e ---   T 6 --- P R H *   F o r u s e w i t h 1 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , 5 --- 2 D a y P r o g r a m m a b l e --- T 2 --- PA C   T H E R M O S TA T ---   PROGRAMMABLE   F o r u s e w i t h m u l t i --- s t a g e a p p l i c a t i o n s --- d e g . F / C , A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e ---   T 6 --- P H P }   F o r m u l t i --- u s e / s t a g e c o n f i g u r a t i o n s --- d e g . F / C , A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e /   Temperature and Humidity Control ---T6---PRH{   Comfort Series Three---Zone Zone Kit --- ZONEBB3ZAC01, ZONEBB3ZHP01   2---Performance Series Zoning/Temperature and Humidity Control --- ZONEBB2KIT01---B   4---Performance Series Zoning/Temperature and Humidity Control --- ZONEBB4KIT01---B   8---Performance Series Zoning/Temperature and Humidity Control --- ZONEBB8KIT01---B   ZONING CONTROL   *Factory---authorized and field---installed. Gas conversion kits are CSA (A.G.A./C.G.A.) recognized   Required for installation on combustible floors when no coil box is used, or when any coil box other than a Bryant cased coil is used.   *Model HP and 2S thermostat must be field converted to air conditioner operation.   {Thermidistatt Control control can be configured for multiple use and staging. It must be configured for each specific application.   }Dual Fuel thermostat is used with furnace and heat pump application.   5 Download from Www.Somanuals.com. All Manuals Search And Download.   A88202   A96214   CONCENTRICA93086   DOWNFLOW   SUBBASE   BRYANT CASED   VENT (DIRECT VENT/   N-COIL   One base fits all furnace sizes.   The base is designed to be in-   stalled between the furnace and a   combustible floor when no coil   box is used or when a coil box   other than a Bryant cased coil is   used. It is CSA (A.G.A./C.G.A.)   design certified for use with select   2-PIPE ONLY)   A concentric vent kit allows vent   and combustion-air pipes to   terminate through a single exit   in a roof or side wall.   (as shown)   The Bryant Cased N-Coil or   A-Coil is an upflow/downflow   furnace coil which can also   replace the downflow subbase   when installing select Bryant   furnaces on combustible flooring   in the downflow orientation.   One pipe runs inside the other   allowing venting through the   inner pipe and combustion air to   be drawn in through the outer   pipe.   Bryant furnaces when installed in   downflow applications.   A08450   A97432   CONTROLS:   THERMOSTATS   AND ZONING   C04009   A01484   Available in programmable and   non-programmable models,   Bryant thermostats maintain a   constant, comfortable tempera-   ture level in the home.   ENERGY/HEAT RECOVERY   VENTILATOR   MECHANICAL   HUMIDIFIER   OR ELECTRONIC   AIR CLEANER   Bryant’s energy or heat recovery   ventilators exhaust stale indoor   air and provide fresh outdoor air   to the home while minimizing   heat loss and humidity level.   Especially useful for today’s   tighter constructed houses.   By adding moisture to winter-dry   air, a Bryanthumidifier can often   improve comfort and keep   furniture, rugs, and draperies in   better condition. Moisturizing   household air also helps to retain   normal body heat and provides   comfort at lower temperatures.   Cleans the air of smoke, dirt, and   many pollens commonly found.   Saves decorating and cleaning   expenses by keeping carpets,   furniture, and drapes cleaner.   For the ultimate in home comfort,   Bryant’s 2, 4, and 8-zone systems   allow temperature control of indi-   vidual “zones” of the home. This is   accomplished through a series of   electronic dampers and   Electronic air cleaner is shown.   remote room sensors.   The   Energy recovery ventilator   is shown.   4-zone system is shown.   A08153   6 Download from Www.Somanuals.com. All Manuals Search And Download.   A08321   7 Download from Www.Somanuals.com. All Manuals Search And Download.   DOWNFLOW SUBBASE DIMENSIONS -- IN. (MM)   HOLE NO.   FOR   WIDTH   A D J U S T ---   MENT   PLENUM OPENING   FLOOR OPENING   FURNACE   CASING   WIDTH   FURNACE IN DOWNFLOW APPLICATION   A B C D 17-1/2   (445)   21   (533)   24-1/2   (622)   Furnace with or without Cased Coil Assembly or   Coil Box   Furnace with or without Cased Coil Assembly or   Coil Box   Furnace with or without Cased Coil Assembly or   Coil Box   15---1/8   (384)   18---5/8   (473)   22-1/8   (562)   19   16-3/4   (425)   20---1/4   (514)   23-3/4   (603)   20---3/8   (518)   20---3/8   (518)   20---3/8   (518)   3 2 1 (483)   19   (483)   19 (483)   *The plenum should be constructed 1/4---in. (6 mm) smaller in width and depth than the plenum dimensions shown above.   LOCATING   TAB   1 1 / 4 ″ (32 μμ) TYP   PLENUM   OPENING   B D 4 3 2 A 1 LOCATING   TAB   C FACTORY-SUPPLIED   FIELD-INSTALLED   INSULATION   1 2 3 4 COMBUSTION--AIR PIPE FOR NON--DIRECT VENT (1--PIPE) APPLICATION   (SIZES 040 THROUGH 120 ONLY)   FIELD-SUPPLIED   2-IN. (51 mm) DIA.   FIELD-SUPPLIED   PVC 90° ELBOW   2-IN. (51 mm) DIA.   LENGTH OF STRAIGHT   PVC PIPE   PIPE PORTION OF COMBUSTION   AIR INLET PIPE ASSEMBLY - IN. (mm)   CASING WIDTH   A A 17-1/2 (445 mm)   21 (533 mm)   8-1/2 1/2 (216 13 mm)   10-1/2 1/2 (267 13 mm)   12 1/2 (305 13 mm)   24-1/2 (622 mm)   COMBUSTION-AIR DISC   (FACTORY-SUPPLIED IN   LOOSE PARTS BAG)   A96211   CONCENTRIC VENT FOR DIRECT VENT (2--PIPE) APPLICATION (ALL MODEL SIZES)   B IN. (MM) DIA PVC   VENT/EXHAUST   F E C IN. (MM) DIA   13/16 (30 mm)   11/2   (38 mm)   D A B IN. (MM) DIA PVC   INTAKE/COMBUSTION AIR   KIT PART NO.   KGAVT0701CVT   KGAVT0801CVT   A*   B 2 (51)   3 (76)   C D{   E F 33---3/8 (848)   38---7/8 (987)   3---1/2 (89)   4---1/2 (114)   16---5/8 (422)   21---1/8 (537)   6---1/4 (159)   7---3/8 (187)   5---3/4 (146)   6---1/2 (165)   *Dimension A will change accordingly as Dimension D is lengthened or shortened.   {Dimension D may be lengthened to 60---in. (1524 mm) maximum. Dimension D may also be shortened by cutting the pipes provided in the kit to 12--- in. (305   mm) minimum.   8 Download from Www.Somanuals.com. All Manuals Search And Download.   CONDENSATE TRAP   A93026   MEDIA FILTER CABINET   25 58" (651 mm)   / 23 58" (600 mm)   / 24 38" (619 mm)   / Opening with Flanges Bent   23 38" (594 mm)   / 23 1 " (587 mm)   / Open8ing   A Furnace Side   Duct Side   23 34" (603 mm)   / Centerline Screw Slots   5 3   (146 mm)   / 4 Media   Filter Cabinet   Shipped with sizes   A B 040-08, 040-12, 060-08, 060-12,   060-16, 080-12, 080-16   17" (432) 16" (406)   21" (533) 20" (508)   16" (406)   20" (508)   080-20, 100-16, 100-20   120-20, 140-20   24" (610) 25" (635) 24" (610)   A05186   9 Download from Www.Somanuals.com. All Manuals Search And Download.   CLEARANCE TO COMBUSTIBLES   335122-201 REV. B LIT TOP   A08435   10   Download from Www.Somanuals.com. All Manuals Search And Download.   PERFORMANCE DATA   EFFICIENCY   036040   38000   38000   38000   38000   38000   38000   95   UNIT SIZE   036060   56000   56000   56000   56000   56000   56000   036080   75000   75000   74000   75000   74000   74000   048080   75000   75000   75000   75000   75000   75000   93   060100   94000   94000   93000   94000   93000   93000   060120   113000   113000   112000   113000   112000   112000   Upflow   Downflow   Horizontal   Upflow   Downflow   Horizontal   Upflow   CAPACITY* Direct Vent (2---pipe)   (Shaded capacities are specified on   the rating plate)   CAPACITY* Non---Direct vent (1---pipe)   AFUE* Direct Vent (2---pipe)   Downflow   Horizontal   Upflow   93.6   94.4   94.7   91.5   92.3   92.4   Non --- weatherized IC S   AFUE* Non --- Direct Vent (1 --- pipe)   Downflow   Horizontal   93.3   94.1   91.4   91.4   Non-weatherized ICS   Input Btuh {   40000   60000   80000   80000   100000   060100   30---60   (17 --- 33)   0.20   0.50   1890   1635   120000   060120   40---70   (22 --- 39)   0.20   0.50   2065   1925   UNIT SIZE   036040   20---50   (11 --- 28)   0.10   0.50   845   036060   30---60   (17 --- 33)   0.12   0.50   1040   1250   036080   40---70   (22 --- 39)   0.15   0.50   1180   1240   048080   30---60   (17 --- 33)   0.15   0.50   1450   1620   CERTIFIED TEMPERATURE RANGE ---   _F (_C)   CERTIFIED EX STATIC PRESSURE   (in. wc)   AIRFLOW (CFM)}   Heating   Cooling   Heating   Cooling   1260   *Capacity and AFUE in accordance with U.S. Government DOE test procedures.   {Gas input ratings are certified for elevations to 2000 ft. (610 M). For elevations above 2000 ft. (610 M), reduce ratings 2% for each 1000 ft. (305 M) above sea   level. In Canada, derate the unit 5% for elevations 2000 to 4500 ft. (610 to 1372 M) above sea level.   }Airflow shown is for bottom only return---air supply with factory supplied 3/4---in. (19 mm) washable filter(s).   For air delivery above 1800 CFM, see Air Delivery table for other options.   An airflow reduction of up to 7% may occur when using the factory---specified 4 5/16---in. (110 mm) wide, high efficiency media filter.   For best furnace efficiency when using the 4---5/16---in. (110 mm) wide media filter, adjust the blower speed tap to near the mid---point of the rise range.   ICS --- Isolated Combustion System.   11   Download from Www.Somanuals.com. All Manuals Search And Download.   AIR DELIVERY—CFM (WITH FILTER)   EXTERNAL STATIC PRESSURE (in.wc)   0.3 0.4 0.5 0.6 0.7 0.8   1425 1385 1350 1305 1260 1210 1165 1100   UNIT   SIZE   RETURN-AIR   SUPPLY   SPEED   0.1   0.2   0.9   995   795   610   355   - 995   790   590   335   - 1 5(Gry)   4(Yel)   3(Blu)   2(Org)   1(Red)   5(Gry)   3(Blu)   4(Yel)   1(Red)   2(Org)   5(Gry)   3(Blu)   4(Yel)   1(Red)   2(Org)   5(Gry)   3(Blu)   4(Yel)   2(Org)   1(Red)   5(Gry)   3(Blu)   4(Yel)   2(Org)   1(Red)   5(Gry)   3(Blu)   4(Yel)   1(Red)   2(Org)   855   730   560   235   - 845   730   525   200   - 1215 1165 1130 1085 1025   970   790   570   335   905   715   510   245   840   660   450   - SIDE/BOTTOM   SIDE/BOTTOM   SIDE/BOTTOM   SIDE/BOTTOM   SIDE/BOTTOM   SIDE/BOTTOM   036040   036060   036080   048080   060100   060120   1060 1005   960   770   570   910   695   475   845   640   425   890   880   835   675   1430 1390 1345 1300 1250 1205 1150 1080   1240 1200 1145 1100 1040   975   800   565   - 915   730   490   - 860   665   410   - 1090 1030   980   780   440   935   705   380   850   635   300   900   805   835   620   1400 1360 1325 1285 1240 1205 1160 1125 1075 1000   1340 1300 1265 1215 1180 1135 1100 1055 1015   965   800   585   360   1195 1160 1115 1065 1025   985   795   560   935   745   515   895   685   460   850   635   420   1025   855   980   800   935   745   880   680   835   635   1720 1695 1690 1655 1620 1580 1540 1495 1465 1415   1565 1535 1530 1490 1450 1420 1375 1335 1295 1255   1330 1310 1270 1220 1180 1135 1095 1055 1010   970   810   670   1210 1180 1135 1085 1035   1110 1065 1005 960 910   995   865   950   820   910   770   865   720   2070 2020 1985 1925 1890 1850 1795 1755 1690 1610   1815 1775 1730 1690 1635 1595 1555 1500 1460 1410   1580 1535 1480 1440 1380 1380 1340 1285 1235 1185   1380 1325 1275 1220 1220 1165 1105 1060 1000   1170 1105 1055 985 935 870 805 765 705   2250 2205 2155 2110 2065 2020 1970 1925 1870 1790   2130 2085 2030 1980 1925 1880 1830 1775 1730 1675   1890 1835 1790 1740 1690 1640 1590 1535 1480 1435   1640 1585 1525 1475 1425 1365 1315 1260 1200 1140   960   660   1420 1370 1305 1255 1190 1135 1065 1010   940   880   ] • Airflow shown is for bottom only return---air supply with factory supplied 3/4---in. (19 mm) washable filter(s).   For air delivery above 1800 CFM, see Air Delivery table for other options.   An airflow reduction of up to 7% may occur when using the factory---specified 4 5/16---in. (110 mm) wide, high efficiency media filter.   For best furnace efficiency when using the 4 5/16---in. (110 mm) wide media filter, adjust the blower speed tap to near the mid---point of the rise range.   For horizontal and downflow applications, use one side or bottom or bottom only as airflow reference.   12   Download from Www.Somanuals.com. All Manuals Search And Download.   COMBUSTION--AIR AND VENT PIPING FOR DIRECT VENT/2--PIPE (ALL SIZES) AND   NON--DIRECT VENT/1--PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS   NON-DIRECT   VENT (1-PIPE)   ONLY   DIRECT VENT (2-PIPE) ONLY   NUMBER OF 90° ELBOWS   ALTITUDE   FT (M)   UNIT SIZE   (BTUH)   TERMINATION   TYPE   PIPE DIA   IN. (mm)*   PIPE DIA   IN. (mm)*   1 2 3 4 5 6 5 1 (25)   1-1/2 (38)   2 (51)   1 (25)   1-1/2 (38)   2 (51)   NA   NA   NA   NA   NA   (1.5)   70   70   65   60   60   55   2 Pipe or 2-in   Concentric   40,000   60,000   80,000   (21.3)   (21.3)   (19.8)   (18.3)   (18.3)   (16.8)   70   70   70   70   70   70   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   20   15   10   5 1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   NA   NA   (6.1)   (4.6)   (3.0)   (1.5)   2 Pipe or 2-in   Concentric   70   70   70   70   70   70   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   10   1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   NA   NA   NA   NA   NA   (3.0)   55   50   35   30   30   20   2 Pipe or 2-in   Concentric   (16.8)   (15.2)   (10.7)   (9.1)   (9.1)   (6.1)   0 to 2000   (0 to 610)   70   70   70   70   70   70   2-1/2 (64)   2 (51)   2-1/2 (64)   2 (51)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   5 NA   NA   NA   NA   NA   NA   (1.5)   40   30   20   20   10   2 Pipe or 3-in   Concentric   2-1/2 (64)   3 (76)   2-1/2 (64)   3 (76)   100,000   120,000   (12.2)   (9.1)   (6.1)   (6.1)   (3.0)   70   70   70   70   70   70   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   2-1/2 (64)   one disk   10   2-1/2 (64)   NA   NA   NA   NA   NA   NA   (3.0)   45   40   35   30   25   20   2 Pipe or 3-in.   Concentric   3 (76)†   (13.7)   (12.2)   (10.7)   (9.1)   (7.6)   (6.1)   70   70   70   70   70   70   3 (76) † no disk   3 (76)†   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   NON-DIRECT   VENT (1-PIPE)   ONLY   DIRECT VENT (2-PIPE) ONLY   NUMBER OF 90° ELBOWS   ALTITUDE   FT (M)   UNIT SIZE   (BTUH)   TERMINATION   TYPE   PIPE DIA   IN. (mm)*   PIPE DIA   IN. (mm)*   1 2 3 4 5 6 67   62   57   52   52   47   1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   (20.4)   (18.9)   (17.4)   (15.8)   (15.8)   (14.3)   2 Pipe or 2-in   Concentric   40,000   60,000   80,000   100,000   70   70   70   70   70   70   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   17   12   7 1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   NA   NA   NA   (5.2)   (3.7)   (2.1)   2 Pipe or 2-in   Concentric   70   67   66   61   61   61   (21.3)   (20.4)   (20.1)   (18.6)   (18.6)   (18.6)   49   44   30   25   25   15   2 (51)   2 (51)   (14.9)   (13.4)   (9.1)   (7.6)   (7.6)   (4.6)   2 Pipe or 2-in   Concentric   70   70   70   70   70   70   2-1/2 (64)   2-1/2 (64)   3 (76)   2-1/2 (64)   2-1/2 (64)   3 (76)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   2001 to 3000   (610 to 914)   35   26   16   16   6 NA   (10.7)   (7.9)   (4.9)   (4.9)   (1.8)   2 Pipe or 3-in   Concentric   70   70   70   70   66   61   (21.3)   (21.3)   (21.3)   (21.3)   (20.1)   (18.6)   14   9 3 (76)   NA   NA   NA   NA   NA   (4.3)   (2.7)   63   62   62   61   61   61   NA   3 (76)†   (19.2)   (18.9)   (18.9)   (18.6)   (18.6)   (18.6)   2 Pipe or 3-in.   Concentric   120,000   70   70   63   56   50   43   3 (76)† no disk   NA   (21.3)   (21.3)   (19.2)   (17.1)   (15.2)   (13.1)   4 (102)† no   disk   70   70   70   70   70   70   4 (102)† no disk   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   See notes at end of table.   13   Download from Www.Somanuals.com. All Manuals Search And Download.   COMBUSTION--AIR AND VENT PIPING FOR DIRECT VENT/2--PIPE (ALL SIZES) AND   NON--DIRECT VENT/1--PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS (CON’T.)   NON-DIRECT   VENT (1-PIPE)   ONLY   DIRECT VENT (2-PIPE) ONLY   NUMBER OF 90° ELBOWS   ALTITUDE   FT (M)   UNIT SIZE   (BTUH)   TERMINATION   TYPE   PIPE DIA   IN (mm)*   PIPE DIA   IN (mm)*   1 2 3 4 5 6 64   59   54   49   48   43   1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   (19.5)   (18.0)   (16.5)   (14.9)   (14.6)   (13.1)   2 Pipe or 2-in   Concentric   40,000   60,000   80,000   100,000   70   70   70   70   70   70   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   16   11   6 1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   NA   NA   NA   (4.9)   (3.4)   (1.8)   2 Pipe or 2-in   Concentric   68   63   62   57   57   56   (20.7)   (19.2)   (18.9)   (17.4)   (17.4)   (17.1)   46   41   28   23   22   13   2 (51)   2 (51)   (14.0)   (12.5)   (8.5)   (7.0)   (6.7)   (4.0)   2 Pipe or 2-in   Concentric   70   70   70   70   70   70   3001 to 4000   (914 to 1219)   2-1/2 (64)   2-1/2 (64)   3 (76)   2-1/2 (64)   2-1/2 (64)   3 (76)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   33   24   15   14   5 NA   (10.1)   (7.3)   (4.6)   (4.3)   (1.5)   2 Pipe or 3-in   Concentric   70   70   70   66   61   56   (21.3)   (21.3)   (21.3)   (20.1)   (18.6)   (17.1)   65   58   51   44   38   31   3 (76)† no disk   NA   NA   (19.8)   (17.7)   (15.5)   (13.4)   (11.6)   (9.4)   2 Pipe or 3-in.   Concentric   59   59   58   57   57   56   3 (76)†   120,000   (18.0)   (18.0)   (17.7)   (17.4)   (17.4)   (17.1)   4 (102)† no   disk   70   70   70   70   70   70   4† no disk   4 (102) † no disk   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   NON-DIRECT   VENT (1-PIPE)   ONLY   DIRECT VENT (2-PIPE) ONLY   NUMBER OF 90° ELBOWS   ALTITUDE   FT (M)   UNIT SIZE   (BTUH)   TERMINATION   TYPE   PIPE DIA   IN. (mm)*   PIPE DIA   IN. (mm)*   1 2 3 4 5 6 60   55   50   45   44   39   1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   (18.3)   (16.8)   (15.2)   (13.7)   (13.4)   (11.9)   2 Pipe or 2-in   Concentric   40,000   60,000   80,000   100,000   70   70   70   70   70   70   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   15   10   5 1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   NA   NA   NA   (4.6)   (3.0)   (1.5)   2 Pipe or 2-in   Concentric   64   59   58   53   52   52   (19.5)   (18.0)   (17.7)   (16.2)   (15.8)   (15.8)   44   39   26   21   20   11   2 (51)   2 (51)   (13.4)   (11.9)   (7.9)   (6.4)   (6.1)   (3.4)   2 Pipe or 2-in   Concentric   70   70   70   70   70   70   4001 to 5000‡   (1219 to 1524)   2-1/2 (64)   2-1/2 (64)   3 (76)   2-1/2 (64)   2-1/2 (64)   3 (76)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   31   22   13   12   NA   NA   (9.4)   (6.7)   (4.0)   (3.7)   2 Pipe or 3-in   Concentric   70   70   67   62   57   52   (21.3)   (21.3)   (20.4)   (18.9)   (17.4)   (15.8)   3 (76)†   no disk   53   46   40   33   26   20   NA   (16.2)   (14.0)   (12.2)   (10.1)   (7.9)   (6.1)   56   55   54   53   52   52   2 Pipe or 3-in.   Concentric   NA   3 (76)†   120,000   (17.1)   (16.8)   (16.5)   (16.2)   (15.8)   (15.8)   4 (102)† no   disk   70   70   70   70   70   70   4 (102)† no disk   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   See notes at end of table.   14   Download from Www.Somanuals.com. All Manuals Search And Download.   COMBUSTION--AIR AND VENT PIPING FOR DIRECT VENT/2--PIPE (ALL SIZES) AND   NON--DIRECT VENT/1--PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS (CON’T.)   NON-DIRECT   VENT (1-PIPE)   ONLY   DIRECT VENT (2-PIPE) ONLY   NUMBER OF 90° ELBOWS   ALTITUDE   FT (M)   UNIT SIZE   (BTUH)   TERMINATION   TYPE   PIPE DIA   IN. (mm)*   PIPE DIA   IN. (mm)*   1 2 3 4 5 6 57   52   47   42   40   35   1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   (17.4)   (15.8)   (14.3)   (12.8)   (12.2)   (10.7)   2 Pipe or 2-in   Concentric   40,000   60,000   80,000   100,000   70   70   70   70   70   70   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   14   9 1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   NA   NA   NA   NA   (4.3)   (2.7)   2 Pipe or 2-in   Concentric   60   55   54   49   48   47   (18.3)   (16.8)   (16.5)   (14.9)   (14.6)   (14.3)   41   36   23   18   17   8 2 (51)   2 (51)   (12.5)   (11.0)   (7.0)   (5.5)   (5.2)   (2.4)   2 Pipe or 2-in   Concentric   70   70   70   70   70   70   5001 to 6000‡   (1524 to 1829)   2-1/2 (64)   2-1/2 (64)   3 (76)   2-1/2 (64)   2-1/2 (64)   3 (76)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   29   21   12   11   NA   NA   (8.8)   (6.4)   (3.7)   (3.4)   2 Pipe or 3-in   Concentric   70   67   62   57   52   47   (21.3)   (20.4)   (18.9)   (17.4)   (15.8)   (14.3)   3 (76)†   no disk   42   35   29   22   15   9 NA   (12.8)   (10.7)   (8.8)   (6.7)   (4.6)   (2.7)   53   52   50   49   48   47   2 Pipe or 3-in.   Concentric   NA   3 (76)†   120,000   (16.2)   (15.8)   (15.2)   (14.9)   (14.6)   (14.3)   4 (102)† no   disk   70   70   70   70   70   70   4 (102)† no disk   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   (21.3)   NON-DIRECT   VENT (1-PIPE)   ONLY   DIRECT VENT (2-PIPE) ONLY   NUMBER OF 90° ELBOWS   ALTITUDE   FT (M)   UNIT SIZE   (BTUH)   TERMINATION   TYPE   PIPE DIA   IN. (mm)*   PIPE DIA   IN. (mm)*   1 2 3 4 5 6 53   48   43   38   37   32   1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   (16.2)   (14.6)   (13.1   (11.6)   (11.3)   (9.8)   2 Pipe or 2-in   Concentric   40,000   60,000   80,000   100,000   120,000   70   70   68   67   66   64   (21.3)   (21.3)   (20.7)   (20.4)   (20.1)   (19.5)   13   8 1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   NA   NA   NA   NA   (4.0)   (2.4)   2 Pipe or 2-in   Concentric   57   52   50   45   44   43   (17.4)   (15.8)   (15.2)   (13.7)   (13.4)   (13.1)   38   33   21   16   15   6 2 (51)   2 (51)   (11.6)   (10.1)   (6.4)   (4.9)   (4.6)   (1.8)   6001 to 7000‡   (1829 to 2134)   2 Pipe or 2-in   Concentric   70   70   68   67   66   64   2-1/2 (64)   2-1/2 (64)   3 (76)   2-1/2 (64)   2-1/2 (64)   3 (76)   (21.3)   (21.3)   (20.7)   (20.4)   (20.1)   (19.5)   27   19   10   9 NA   NA   (8.2)   (5.8)   (3.0)   (2.7)   2 Pipe or 3-in   Concentric   68   63   58   53   48   43   (20.7)   (19.2)   (17.7)   (16.2)   (14.6)   (13.1)   3 (76)†   no disk   31   24   18   11   NA   NA   NA   (9.4)   (7.3)   (5.5)   (3.4)   2 Pipe or 3-in.   Concentric   49   48   47   45   44   43   NA   3 (76)†   (14.9)   (14.6)   (14.3)   (13.7)   (13.4)   (13.1)   See notes at end of table.   15   Download from Www.Somanuals.com. All Manuals Search And Download.   COMBUSTION--AIR AND VENT PIPING FOR DIRECT VENT/2--PIPE (ALL SIZES) AND   NON--DIRECT VENT/1--PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS (CON’T.)   NON-DIRECT   VENT (1-PIPE)   ONLY   ALTITUDE   FT (M)   UNIT SIZE   (BTUH)   DIRECT VENT (2-PIPE) ONLY   NUMBER OF 90° ELBOWS   TERMINATION   TYPE   PIPE DIA   IN. (mm)*   PIPE DIA   IN. (mm)*   1 2 3 4 5 6 49   44   39   34   33   28   1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   (14.9)   (13.4)   (11.9)   (10.4)   (10.1)   (6.5)   2 Pipe or 2-in   Concentric   40,000   60,000   80,000   100,000   66   65   63   62   60   59   (20.1)   (19.8)   (19.2)   (18.9)   (18.3)   (18.0)   12   7 1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   NA   NA   NA   NA   (3.7)   (2.1)   2 Pipe or 2-in   Concentric   53   48   46   41   40   38   (16.2)   (14.6)   (14.0)   (12.5)   (12.2)   (11.6)   36   31   19   14   12   2 (51)   2 (51)   NA   (11.0)   (9.4)   (5.8)   (4.3)   (3.7)   2 Pipe or 2-in   Concentric   66   65   63   62   60   59   7001 to 8000‡   (2134 to 2438)   2-1/2 (64)   2-1/2 (64)   3 (76)   2-1/2 (64)   2-1/2 (64)   3 (76)   (20.1)   (19.8)   (19.2)   (18.9)   (18.3)   (18.0)   25   17   8 7 NA   NA   (7.6)   (5.2)   (2.4)   (2.1)   2 Pipe or 3-in   Concentric   63   58   53   48   43   38   (19.2)   (17.7)   (16.2)   (14.6)   (13.1)   (11.6)   20   13   7 3 (76)† no disk   NA   NA   NA   NA   NA   (6.1)   (4.0)   (2.1)   46   44   43   41   40   38   2 Pipe or 3-in.   Concentric   3 (76)†   120,000   (14.0)   (13.4)   (13.1)   (12.5)   (12.2)   (11.6)   4 (102)† no   disk   61   56   51   46   41   36   4 (102)† no disk   (18.6)   (17.1)   (15.5)   (14.0)   (12.5)   (11.0)   NON-DIRECT   VENT (1-PIPE)   ONLY   ALTITUDE   FT (M)   UNIT SIZE   (BTUH)   DIRECT VENT (2-PIPE) ONLY   NUMBER OF 90° ELBOWS   TERMINATION   TYPE   PIPE DIA   IN. (mm)*   PIPE DIA   IN. (mm)*   1 2 3 4 5 6 46   41   36   31   29   24   1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   (14.0)   (12.5)   (11.0)   (9.4)   (8.8)   (7.3)   2 Pipe or 2-in   Concentric   40,000   60,000   80,000   100,000   62   60   58   56   55   53   (18.9)   (18.3)   (17.7)   (17.1)   (16.8)   (16.2)   11   6 1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   NA   NA   NA   NA   (3.4)   (1.8)   2 Pipe or 2-in   Concentric   49   44   42   37   35   34   (14.9)   (13.4)   (12.8)   (11.3)   (10.7)   (10.4)   33   28   17   12   10   2 (51)   2 (51)   NA   (10.1)   (8.5)   (5.2)   (3.7)   (3.0)   2 Pipe or 2-in   Concentric   62   60   58   56   55   53   8001 to 9000‡   (2438 to 2743)   2-1/2 (64)   2-1/2 (64)   3 (76)   2-1/2 (64)   2-1/2 (64)   3 (76)   (18.9)   (18.3)   (17.7)   (17.1)   (16.8)   (16.2)   23   15   7 5 NA   NA   (7.0)   (4.6)   (2.1)   (1.5)   2 Pipe or 3-in   Concentric   59   54   49   44   39   34   (18.0)   (16.5)   (14.9)   (13.4)   (11.9)   (10.4)   10   3 (76)† no disk   NA   NA   NA   NA   NA   NA   NA   (3.0)   43   41   39   37   35   34   2 Pipe or 3-in.   Concentric   3 (76)†   4† no disk   120,000   (13.1)   (12.5)   (11.9)   (11.3)   (10.7)   (10.4)   4 (102)† no   disk   35   30   25   20   15   10   (10.7)   (9.1)   (7.6)   (6.1)   (4.6)   (3.0)   See notes at end of table.   16   Download from Www.Somanuals.com. All Manuals Search And Download.   COMBUSTION--AIR AND VENT PIPING FOR DIRECT VENT/2--PIPE (ALL SIZES) AND   NON--DIRECT VENT/1--PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS (CON’T.)   NON-DIRECT   ALTITUDE   FT (M)   UNIT SIZE   (BTUH)   VENT (1-PIPE)   ONLY   DIRECT VENT (2-PIPE) ONLY   NUMBER OF 90° ELBOWS   TERMINATION   TYPE   PIPE DIA   IN. (mm)*   PIPE DIA   IN. (mm)*   1 2 3 4 5 6 42   37   32   27   25   20   2 Pipe or 2-in   Concentric   1-1/2 (38)   2 (51)   1-1/2 (38)   2 (51)   (12.8)   (11.3)   (9.8)   (8.2)   (7.6)   (6.1)   40,000   60,000   80,000   57   55   53   51   49   47   (17.4)   (16.8)   (16.2)   (15.5)   (14.9)   (14.3)   2 Pipe or 2-in   Concentric   45   40   38   33   31   29   2 (51)   2 (51)   (13.7)   (12.2)   (11.6)   (10.1)   (9.4)   (8.8)   30   25   14   9 7 2 (51)   2 (51)   NA   (9.1)   (7.6)   (4.3)   (2.7)   (2.1)   2 Pipe or 2-in   Concentric   57   55   53   51   49   47   9001 to 10,000‡   (2743 to 3048)   2-1/2 (64)   2-1/2 (64)   3 (76)   2-1/2 (64)   2-1/2 (64)   3 (76)   (17.4)   (16.8)   (16.2)   (15.5)   (14.9)   (14.3)   21   13   5 NA   NA   NA   (6.4)   (4.0)   (1.5)   2 Pipe or 3-in   Concentric   100,000   120,000   54   49   44   39   34   29   (16.5)   (14.9)   (13.4)   (11.9)   (10.4)   (8.8)   39   37   35   33   31   29   NA   3 (76)†   (11.9)   (11.3)   (10.7)   (10.1)   (9.4)   (8.8)   2 Pipe or 3-in.   Concentric   4 (102)† no   disk   10   5 4 (102)† no disk   NA   NA   NA   NA   (3.0)   (1.5)   * Disk usage-Unless otherwise specified, use perforated disk assembly (factory-supplied in loose parts bag).   # If one disk is stated, separate 2 halves of perforated disk assembly and use shouldered disk half. When using shouldered disk half, install screen side toward inlet box.   † Wide radius elbow.   ‡ Vent sizing for Canadian installations over 4500 ft (1370 M) above sea level are subject to acceptance by the local authorities having jurisdiction. NA-Not Allowed;   pressure switch will not make.   NOTES:   1. Do not use pipe size greater than those specified in table or incomplete combustion, flame disturbance, or flame sense lockout may occur.   2. Size both the combustion-air and vent pipe independently, then use the larger diameter for both pipes.   3. Assume two 45° elbows equal one 90° elbow. Wide radius elbows are desirable and may be required in some cases.   4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.   5. The minimum pipe length is 5 ft (1.5 M) for all applications.   6. Use 3-in. (76 mm) diameter vent termination kit for installations requiring 4-in (102 mm) diameter pipe.   17   Download from Www.Somanuals.com. All Manuals Search And Download.   MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH -- FT (M) WITH AND   WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT*   WINTER DESIGN   TEMPERATURE   °F 〈°C)   MAX PIPE   DIAMETER   IN (mm)   WITHOUT   INSULATION   FT (M)   WITH 3/8–IN. OR THICKER   INSULATION†   FURNACE SIZE   FT (M)   20 (---7)   0 ( --- 18)   --- 20 ( --- 29)   20 (---7)   0 ( --- 18)   --- 20 ( --- 29)   20 (---7)   0 ( --- 18)   --- 20 ( --- 29)   20 (---7)   0 ( --- 18)   --- 20 ( --- 29)   20 (---7)   0 ( --- 18)   --- 20 ( --- 29)   20 (---7)   0 ( --- 18)   --- 20 ( --- 29)   20 (---7)   0 ( --- 18)   --- 20 ( --- 29)   20 (---7)   0 ( --- 18)   --- 20 ( --- 29)   20 (---7)   1.5 (38)   1.5 (38)   1.5 (38)   2 (51)   2 (51)   2 (51)   2 (51)   2 (51)   2 (51)   2 (51)   51 (16)   28 (9)   16 (5)   45 (14)   22 (7)   10 (3)   70 (21)   70 (21)   70 (21)   70 (21)   70 (21)   58 (18)   70 (21)   70 (21)   70 (21)   55 (17)   55 (17)   55 (17)   70 (21)   70 (21)   70 (21)   40 (12)   40 (12)   40 (12)   70 (21)   70 (21)   70 (21)   70 (21)   70 (21)   70 (21)   70 (21)   70 (21)   70 (21)   040   65 (20)   35 (11)   20 (6)   55 (17)   48 (15)   30 (9)   70 (21)   47 (14)   28 (9)   40 (12)   40 (12)   38 (12)   70 (21)   50 (15)   28 (9)   060   080   2 (51)   2 (51)   2.5 (64)   2.5 (64)   2.5 (64)   2.5 (64)   2.5 (64)   2.5 (64)   3 (76)   3 (76)   3 (76)   3 (76)   3 (76)   100   120   70 (21)   61 (19)   37 (11)   70 (21)   48 (15)   23 (7)   3 (76)   4 (102)   4 (102)   4 (102)   0 ( --- 18)   --- 20 ( --- 29)   * Pipe length ft (M) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowable pipe length   as specified in Table.   † Insulation thickness based on R value of 3.5 per in.   18   Download from Www.Somanuals.com. All Manuals Search And Download.   ELECTRICAL DATA   UNIT SIZE   U N I T V O LT S --- H E R T Z --- P H A S E   MAXIMUM UNIT AMPS   036040   115 --- 60 --- 1   036060   115 --- 60 --- 1   9.4   036080   115 --- 60 --- 1   9.4   048080   115 --- 60 --- 1   9.6   060100   115 --- 60 --- 1   12.1   060120   115 --- 60 --- 1   12.1   8 10.8   14   UNIT AMPACITY   MINIMUM WIRE SIZE   12.5   14   12.5   14   12.8   14   15.9   12   15.9   12   MAXIMUM WIRE LENGTH --- FT (M)   MAXIMUM FUSE OR CKT BKR (Amps)**   TRANSFORMER (24v)   34 (10.3)   15   29 (8.8)   15   29 (8.8)   15   29 (8.8)   15   36 (10.9)   20   36 (10.9)   20   40va   HEATING   COOLING   12va   21va   EXTERNAL CONTROL   POWER AVAILABLE   AIR CONDITIONING BLOWER RELAY   24v Standard   TYPICAL WIRING SCHEMATIC   FIELD 24-V WIRING   FIELD 115-, 208/230-, 460-V WIRING   FACTORY 24-V WIRING   FACTORY 115-V WIRING   NOTE 2   THERMOSTAT   TERMINALS   W C R G Y FIVE WIRE   FIELD-SUPPLIED   DISCONNECT   THREE-WIRE   HEATING-ONLY   208/230- OR   BLOWER DOOR SWITCH   460-V   THREE   PHASE   W R BLK   BLK   C O N T R O L WHT   WHT   208/230-V   SINGLE   PHASE   GND   GND   G AUXILIARY   J-BOX   115-V FIELD-   SUPPLIED   DISCONNECT   COM   Y/Y2   GND   NOTE 1   CONDENSING   UNIT   TWO   WIRE   24-V   TERMINAL   BLOCK   NOTES: 1. Connect Y-terminal in furnace as shown for proper blower operation.   2. Some thermostats require a "C" terminal connection as shown.   3. If any of the original wire, as supplied, must be replaced, use   same type or equivalent wire.   FURNACE   A99440   19   Download from Www.Somanuals.com. All Manuals Search And Download.   TYPICAL INSTALLATIONS   COMBUSTION AIR PIPE   (DIRECT VENT/2-PIPE APPLICATION)   OUTDOOR UNIT   VENT PIPE   A/C COIL   HUMIDIFIER   COMBUSTION   AIR INLET   (NON-DIRECT   1-PIPE APPLICATION)   GAS-FIRED   WATER HEATER   ELECTRONIC   AIR CLEANER   FRONT OF   FURNACE   AIRFLOW   A05064   Upflow Application   ELECTRONIC   AIR CLEANER   VENT   COMBUSTION AIR   INLET (NON-DIRECT   VENT/ 1-PIPE APPLICATION   COMBUSTION   AIR (DIRECT VENT/   2 PIPE APPLICATION   HUMIDIFIER   OUTDOOR   UNIT   A/C COIL   AIRFLOW   FRONT OF   FURNACE   A05065   Downflow Application   20   Download from Www.Somanuals.com. All Manuals Search And Download.   TYPICAL INSTALLATIONS (CONTINUED)   COMBUSTION-AIR INLET   (NON-DIRECT VENT/1-PIPE APPLICATION)   COMBUSTION–AIR PIPE   DIRECT VENT/2-PIPE APPLICATION)   VENT PIPE   ELECTRONIC   AIR CLEANER   FRONT OF FURNACE   FURNACE   CONDENSATE   DRAIN   AIR CONDITIONING   COIL   REFRIGERATION   PIPING   AIRFLOW   A05066   Attic -- Horizontal Application   COMBUSTION– AIR PIPE   (DIRECT VENT/2-PIPE   APPLICATION)   COMBUSTION - AIR INLET   (NON-DIRECT VENT/   1-PIPE APPLICATION)   VENT   PIPE   REFRIGERATION   PIPING   AIR CONDITIONING   COIL   ELECTRONIC   AIR CLEANER   FURNACE CONDENSATE   DRAIN   FRONT OF   FURNACE   A08422   Crawlspace -- Horizontal Application   21   Download from Www.Somanuals.com. All Manuals Search And Download.   Filters   GUIDE SPECIFICATIONS   Plus 90x   Furnace shall have reusable--type filters. Filter shall be ______ in   (x) ______in. An accessory high efficiency Media Filter is   available as an option. ______________Media Filter.   Single--Stage/Deluxe Gas Furnace   353AAV   Casing   Casing shall be of .030 in. (.03 mm) thickness minimum,   pre--painted galvanized steel.   GENERAL   System Description   Inducer Motor   Inducer motor shall be soft mounted to reduce vibration   transmission.   Furnish   a _________________ (4--way multipoise) fixed   capacity gas--fired condensing furnace for use with natural gas or   propane (factory authorized conversion kit required for propane);   furnish cold air return plenum; furnish external medial cabinet for   use with accessory media filter or standard filter.   Primary Heat Exchangers   Primary Heat exchangers shall be 3--Pass 20 gauge corrosion   resistant aluminized steel of fold--and--crimp sectional design,   which operates under negative pressure.   Quality Assurance   Unit will be designed, tested and constructed to the current ANSI   Z 21.47/CSA 2.3 design standard for gas--fired central furnaces.   Secondary Heat Exchangers   Secondary Heat exchangers shall be of a flow--through design   having a patented interior laminate coating of polypropylene for   greater corrosion resistance with fold--and--crimp design, which   operates under negative pressure.   Unit will be 3rd party certified by CSA to the current ANSI Z   21.47/CSA 2.3 design standard for gas--fired central furnaces.   Unit will carry the CSA Blue Star® and Blue Flame® labels.   Unit efficiency testing will be performed per the current DOE test   procedure as listed in the Federal Register.   Controls   Controls shall include   a microprocessor based integrated   Unit will be certified for capacity and efficiency and listed in the   latest GAMA Consumer’s Directory of Certified Efficiency   Ratings.   Unit will carry the current Federal Trade Commission Energy   Guide efficiency label.   electronic control board with at least 11 service troubleshooting   codes displayed via diagnostic flashing LED light on the control,   has ability to store fault codes, when activated a self--test feature   checks all major functions of the furnace within one minute, and   a replaceable automotive--type circuit protection fuse. Multiple   operational settings available including separate blower speeds.   Cooling airflow will be selectable between 350 or 400 CFM per   ton of air conditioning. Features will also include temporary   reduced airflow in the cooling mode for improved   dehumidification when a Thermidistat® is selected as the   thermostat.   Delivery, Storage and Handling   Unit will be shipped as single package only and is stored and   handled per unit manufacturer’s recommendation.   Warranty (for inclusion by specifying engineer)   U.S. and Canada only. Warranty certificate available upon   request.   Operating Characteristics   PRODUCTS   Equipment   Heating   Capacity   shall   be_________Btuh   input;____________Btuh output capacity. Fuel Gas Efficiency   shall be 93% AFUE. Air delivery shall be__________ CFM   minimum at 0.50 in. wc. external static pressure. Dimensions   shall be: depth__________in.; width__________in.; height   _________in. (casing only). Height shall be__________in. with   A/C coil and____________in. overall with plenum.   Components shall include: slow--opening gas valve to reduce   ignition noise, regulate gas flow, with electric switch gas   shut--off; flame proving sensor, hot surface igniter, pressure   switch assembly verifies inducer operation; flame rollout switch,   drain tubing and installed condensate drain trap, blower and   inducer assembly, 40va transformer; low--voltage (heating)   (heating/ cooling) thermostat.   Electrical Requirements   Electrical supply shall be 115 volts, 60 Hz, single--phase   (nominal). Minimum wire size shall be_________AWG;   maximum fuse size or HACR--type, designated circuit breaker   shall be _______Amps.   Blower Wheel and Blower Motor   Galvanized blower wheel shall be centrifugal type, statically and   dynamically balanced. Blower motor of ECM type shall be   permanently lubricated with sealed bearings, of _____ hp, and   shall be multiple--speed direct drive. Blower motor shall be soft   mounted to the blower scroll to reduce vibration transmission.   Special Features   Refer to section of the product data sheet identifying accessories   and descriptions for specific features and available enhancements.   E2010 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231   Printed in U.S.A.   Edition Date: 09/10   Catalog No. PDS353AAV--- 0 3   Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.   Replaces: PDS353AAV---02   22   Download from Www.Somanuals.com. All Manuals Search And Download.   |