Bosch Appliances Smoke Alarm FMM100SAT2CKEX User Manual

Fire Alarm Systems | FMM‑100SAT2CKEX Explosion‑proof Fire Alarm Manual Station  
FMM‑100SAT2CKEX Explosion‑proof Fire  
Alarm Manual Station  
Special hazard protection; NEMA 4X and marine  
ratings  
Gold‑plated alarm contacts for corrosion resistance  
Key lock reset with optional break rod  
ADA compliant; UL Listed, FM Approved  
Region  
Certification  
The FMM‑100SAT2CKEX is a high‑quality, die‑cast metal fire  
alarm manual station that is UL and FM Listed for use in  
Class I, Division I, Groups B, C, and D; Class II, Division I,  
Groups E, F, and G; and Class III (FM Listed only) hazardous  
locations. It is also marine and NEMA 4X rated for use in  
harsh environments. It complies with Americans with  
Disabilities Act (ADA) requirements and meets ADA  
standards for wheelchair access when properly installed.  
USA  
UL  
UCCM: Boxes, Non-Coded, Marine, UHMV:  
Fire Alarm Devices for Use in Hazardous  
Locations (Signal Communications)  
FM  
(Signal Communications)  
7151-1408: 112  
CSFM  
NYC/MEA  
NEMA  
382‑94‑E, Vol. 5  
Complies with National Equipment Manu-  
facturers Association NEMA 4X  
ADA  
Complies with Americans with Disabilities  
Act  
Functions  
Operation  
When the bar on the front of the manual station is pulled, it  
latches open and is easily visible from 50 ft (15 m). Reset  
the activation bar by opening the manual station with the  
key and placing the activation bar in its normal upright  
position. An optional scored acrylic break rod is provided.  
Installation/Configuration Notes  
Compatibility Information  
Compatible with all Bosch Security Systems, Inc. Fire Alarm  
Control Panels.  
Mounting Considerations  
The FMM‑100SAT2CKEX Explosion‑proof Manual Station  
must be surface mounted on a flat wall. It has two conduit  
entries. Any conduit entry that is not used must be plugged.  
Certifications and Approvals  
Signal Communications Corp. holds these listings and  
approvals:  
To comply with ADA standards, the manual station must be  
less than 48 in. (1.2 m) above the floor for front wheelchair  
access and less than 54 in. (1.3 m) above the floor for side  
wheelchair access.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Bissell Carpet Cleaner 39W7 User Manual
Black Decker Vacuum Cleaner CHV1410L User Manual
Bosch Appliances Coffeemaker TCA 6301 UC User Manual
Bose Portable Speaker SE 5 User Manual
Bravetti Food Processor BP101H User Manual
Breadman Bread Maker Stainless Steel Convection Bread Maker User Manual
Broilmaster Gas Grill DPSBSS 1 User Manual
Califone Headphones 3060AV User Manual
Chevrolet Automobile 2010 Silverado Hybrid User Manual
Cisco Systems Computer Hardware 7326 User Manual