Bosch Appliances Home Security System 20 User Manual

TCB4 Upgrade Kit for LBB 3500/00, /10 and /30  
LBB 3500/00 and LBB 3500/10  
LBB 3500/30  
SecuritySystems  
Installation Instruction  
en LBB 3519/20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 1. Upgrade Kit LBB 3519/20  
en | 3  
Chapter 1. Upgrade Kit LBB 3519/20  
LBB 3500/xx  
Introduction  
TheupgradekitLBB3519/20isintendedforupgradingofthefollowingDCNCentral  
Control Units:  
TCB 2 or 3  
LBB 3500/00 (D)  
LBB 3500/10 (D)  
LBB 3500/30 (D)  
LBB 3500/xx (with upgrade)  
The upgrade kit LBB 3519/20 (Trunk Communication Board (TCB 4)) once installed  
in the Central Control Units provides the CCUs’ with a high speed serial RS 232  
port. This port can be used for either ‘DIRECT’ connection to a DCN control PC,  
camera control, test/diagnostic purposes or for remote control.  
TCB 4  
Single port only (Port 1)  
The TCB4 has two Ports, Port 1 and Port 2. Both Ports can be used if a second hole is  
made at the rear of the CCU housing to accommodate the second 9-pole D-type  
connector.  
NOTE: The default settings for Port 1 can be changed to suit  
your requirements (see Chapter 3).  
NOTE: If a second port is required, then an additional interconnection cable is  
also required. This cable is ordered separately under Code No. 3922 156  
24090, through your local Bosch supplier.  
LBB 3500/xx (also applicable for LBB 3500/10)  
TCB 2 or 3  
REMARKS:  
1. Using the ‘DIRECT’ connection method the PC-Network card LBB 3510/00 is  
NO longer required.  
2. If a ‘DIRECT’ connection is made between the Control PC and the CCU, the PC  
LBB 3500/xx (with upgrade)  
operator has no connection to the PC for headphone or intercom handset. Additional  
DCN hardware is required for the operator if these functions are required. Use can be  
made of DCN table-top or flush-mounted hardware depending on the requirements.  
TCB 4  
Two ports  
Port 1 - ‘DIRECT’ connection to DCN control PC (default) (see Note)  
Port 2 - Automatic camera control (default) (see Note )  
NOTE: The default settings for Port 1 and 2 can be changed to  
suit your requirements (see Chapter 3.).  
FIGURE 1-1 CCU upgrade kit LBB 3519/20  
Bosch Security Systems | April 03 | 3922 988 97112 en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 1. Upgrade Kit LBB 3519/20  
en | 4  
Installation procedure  
1.1 Before you Begin  
WARNING: Before performing any of the procedures described in this  
1. Remove the top-cover from the CCU.  
2. Locate the TCB (version 2 or 3). For location of the TCB see Fig 1-1.  
document that require you to remove the top-cover of the CCU,  
NOTE: For Multi-CCUs type LBB 3500/30 carefully remove the ‘Multi-CCU’  
card from the TCB card. The TCB is located under the ‘Multi-CCU’ card.  
3. Remove all interconnection cables from the TCB.  
4. Remove the 6 screws securing the TCB,  
1. Before removing the top cover of the CCU, disconnect the mains supply and  
remove the mains cable from its source and from the rear of the CCU.  
2. Disconnect any peripherals connected to the CCU  
3. The TCB4 upgrade interface card is shipped in antistatic packaging for protection  
from electrostatic damage.  
5. Remove the TCB.  
Once the TCB 2 or 3 is removed proceed as follows:  
CAUTION: Before unwrapping the antistatic packaging, ground yourself by  
touching any unpainted metal surface on the Central Control Unit. This proce-  
dure discharges static electricity that might harm the interface card.  
Minor modifications, (i.e. widening the holes to accommodate the 9-pole D-type  
connector(s)) are required at the rear of the CCU. If the upgrade includes two Ports,  
then an additional hole is required to accommodate Port 2.  
REFERENCE: If available refer also to Chapter 4 of the latest  
Digital Congress Network  
Installation and Operating Manual  
editionoftheDCNInstallationandOperatingManual.  
(Code No. 3922 988 433xx).  
1. Remove the TCB from its packaging (see 1.1 Before you Begin)  
2. Position the TCB4 in place and secure using its 6 securing screws.  
3. Position and secure the 9-pole D-type connector(s) in their modified hole(s).  
4. With reference to FIGURE 1-1 and FIGURE 2-1 connect Port 1 and if applicable Port  
2.  
1.2 INSTALLING the TCB4 Interface card  
5. Connect the TCB4 to both 1/O control boards.  
6. Double check connections according to FIGURE 1-1 and FIGURE 2-1.  
1. Your upgrade kit includes:  
- 1 x TCB4 interface card  
1.3 SET-UP of the TCB4 Interface card  
- Interconnection (ribbon) cable terminated with a 9-pole D-type connector at one end  
and a Micromatch connector at the other end.  
To ensure correct operation of the TCB4, the following settings are required:  
1. DIP-switch S14 must be set, to configure the communication protocol and baud  
NOTE: If two ports are required, then an additional interconnection cable is also  
required. This cable is ordered separately under Code no. 3922 156 24090,  
through your local Bosch supplier.  
rate used on Port 1 and Port 2 (see Chapter 3 ).  
2. DIP-switch S9 must be set to configure the boards functionality (see Chapter 2.1 ).  
3. Jumpers X13 and X14 must be set (see Chapter 2.2).  
NOTE: Once the TCB4 has been successfully installed in the CCU, replace the  
top-cover and connect the mains supply to the CCU. Check the CCU for cor-  
rect operation. If the CCU functions correctly, the CCU should be switched ON  
for at least 24 hours to charge the back-up battery located on the TCB4.  
Bosch Security Systems | April 03 | 3922 988 97112 en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 1. Upgrade Kit LBB 3519/20  
en | 5  
Connection to I/O board  
9-pole D-type connector(s)  
Ribbon cabling  
Port 1  
Port 2  
Trunk Communication Board TCB4  
DIP-switch S14  
DIP-switch S9  
6 x securing screws  
Connection to I/O board  
FIGURE 1-2 Internal view of CCU after upgrade  
Bosch Security Systems | April 03 | 3922 988 97112 en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 2. Trunk Communication Board (TCB4)  
en | 6  
DIP-switch S14  
Chapter 2. Trunk Communication Board (TCB4)  
TCB 4  
location Fig. 1-2  
X14  
8 7 6 5 4 3 2 1  
1
2
Key to symbols (fig.2-1) :  
1
2
3
S14  
ON  
8
7
6
5
4
3
2
1
S14  
OFF  
ON  
See Table 3.1 and 3-2  
1
2
3
4
Jumper X14 (see Table 2.2)  
S14 DIP-switches 1 - 8 (see Chapter 3) )  
S10 Push-button switch to reset the Central Control Unit during servicing.  
Three LEDs (left to right) green/yellow/red. Normally the green/yellow LEDs flash in  
sequence, indicating the software is running. Red LED illuminates during system  
reset.  
ON  
1
X14  
8
1
15  
Port 2  
S10  
Reset Switch  
3
S10  
X17a  
X17b  
X41  
X40  
IC1  
14  
IC12  
IC04  
DIP-switch S9  
Port 1  
5
6
S9 DIP-switches 1 - 8 (see Chapter 2.1)  
Yellow LED indicates Digital Signal Processing (DSP) software is running.  
IC11  
13  
multi-C
7Connector  
for  
multi-trunk  
board  
(used  
only  
in  
the  
X10  
1
8
9
Sockets for inserting flash EPROM (even)  
Sockets for inserting flash EPROM (odd)  
SRAM back-up battery 3.6 V (life-time 5 years min.)  
Jumper X13 (see Table 2.2)  
Fuse 3.15 amp (delayed)  
Connector for multi-trunk board (used only in the multi-CCU LBB 3500/30)  
4
5
10  
11  
12  
13  
14  
15  
S9  
See Table 2.1  
Serial RS232 Port 1  
Serial RS232 Port 2  
IC9  
IC8  
6
7
12  
X13  
X11  
BATTERY  
11  
10  
X13  
IC4  
IC3  
9
8
IC6  
X1  
FIGURE 2-1 Layout ‘Trunk Communication Board (TCB 4)  
Bosch Security Systems | April 03 | 3922 988 97112 en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 2. Trunk Communication Board (TCB4)  
en | 7  
2.4 S9 DIP-Switch settings  
2.5 Jumper settings  
See fig. 2-1 for location, and Table 2.1 for functionality of the DIP-switches.  
See fig. 2-1 for location, and Table 2-2 for functionality of the jumpers.  
Table 2.1 : S9 DIP-switch settings  
TCB4  
Table 2.2 : Jumper settings  
TCB4  
Default  
Function  
X13  
1 & 2  
Jumpered to provide SRAM Battery back-up  
Open when removing back-up battery. (Position 2 & 3)  
SW 1  
ON*  
Chairman priority tone ON (default).  
X14  
1 & 2  
Watchdog active  
Open for service purposes. (Position 2 & 3)  
OFF  
ON  
Chairman priority tone OFF  
SW 2  
Audio ‘Mix-Minus’ mode activated in combination with SW3 =  
OFF  
OFF* Normal Operation (default).  
SW 3  
ON  
Audio ‘Insertion’ mode activated in combination with SW2 =  
OFF  
OFF* Normal Operation (default).  
SW 4  
SW 5  
SW 6  
OFF  
OFF  
ON  
Reserved (IMPORTANT: must not be changed)  
Reserved (IMPORTANT: must not be changed)  
Active microphones and request will be permanently switched  
off if the priority function of the chairman unit is used.  
OFF* Active microphones will be switched off temporarily if the prior-  
ity function of the chairman unit is used (default).  
SW 7  
SW 8  
OFF  
ON  
Reserved (IMPORTANT: must not be changed)  
Switching on the CCU will activate the BOOT software, this  
makes a new download possible. All memory settings will be  
erased and returns to the default settings. The unit addresses  
will not be erased.  
OFF* Normal operation (default).  
* = default setting  
DIP switch S9 (default settings)  
switches 4, 5 and 7 are ‘RESERVED’  
Must NOT be changed  
S9  
ON  
For location  
see fig.. 2-1.  
1 2 3 4 5 6 7 8  
Bosch Security Systems | April 03 | 3922 988 97112 en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 3. CCU Protocol and Serial Port settings  
en | 8  
NOTE: It is possible to selectFull’ protocol on both Port 1 and Port 2. However this is NOT  
recommended due to processing power and memory limitations.  
Chapter 3. CCU Protocol and Serial Port settings  
For location of DIP-switches see fig. 2-1  
3.1 LBB 3500/xx (TCB 4) - Port 1 : DCN Control PC  
Port 2 : Camera Control  
In a single (stand-alone) CCU systems two serial COM-ports (Port 1 and Port 2) are  
available. Both ports can be individually configured. Default settings are;  
8 data bits  
No parity check  
1 Stop bit  
Table 3.1 : LBB 3500/xx Protocol settings  
DIP-switch S14  
Port 1  
Port 2  
Switch  
Switch  
DP-1  
OFF  
OFF  
ON*  
Switch  
Switch  
DP-5  
OFF  
OFF  
ON  
DP-2  
OFF  
ON  
OFF*  
ON  
DP-6  
OFF  
ON  
OFF  
ON*  
Simple (Open interface)  
Terminal  
Full  
Camera control  
* default settings  
ON  
ON*  
Table 3.2 : LBB 3500/xx Baud rate settings  
DIP-switch S14  
Port 1  
Switch  
Port 2  
Switch  
DP-3  
OFF  
OFF  
ON  
Switch  
DP-7  
OFF  
OFF*  
ON  
Switch  
DP-8  
OFF  
ON*  
OFF  
ON  
DP-4  
OFF  
ON  
OFF  
ON*  
9.6 K  
19.2 K  
57.6K  
115.2 K  
ON*  
ON  
* default settings  
DIP-switch S14 (default settings)  
8 7 6 5 4 3 2 1  
8 7 6 5 4 3 2 1  
S14  
Port 1 default  
ON  
S14  
ON  
Port 2 default  
Bosch Security Systems | April 03 | 3922 988 97112 en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 3. CCU Protocol and Serial Port settings  
en | 9  
Bosch Security Systems | April 03 | 3922 988 97112 en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
© 2003 Bosch Security Systems B.V.  
Data subject to change without notice  
April 03 | 3922 988 97112 en  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Box Network Router 7000 T1 E1 User Manual
Black Decker Juicer BDPRJE600 AR User Manual
Black Decker PDAs Smartphones CM090 CM090 2 User Manual
Bosch Power Tools Power Hammer 11317EVS User Manual
Bosch Power Tools Saw GCM12SD User Manual
Brinkmann Charcoal Grill Dual Zone Charcoal Grill User Manual
Bushnell GPS Receiver 360400BO User Manual
Campbell Hausfeld Nail Gun IN720501AV User Manual
Campbell Hausfeld Pressure Washer MX5222 User Manual
Chicago Electric Power Screwdriver 9624 User Manual