DinionXF
– LTC 0620 & LTC 0495 series Day/Night cameras
Installation Instructions
Installatiehandleiding
15-bit digital day/night
EN camera
15-bits digitale dag/nacht-
NL camera
Manuale d’installation
Manuale di installazione
Caméra numérique jour/nuit
15 bits
Telecamera giorno/notte
digitale 15 bit
FR
IT
Installationshandbuch
Manual de Instalação
15-Bit digitale Tag-/Nacht-
DE Kamera
Câmara digital dia/noite
de 15 bits
PT
Manual de instalación
安装说明
Cámara día/noche digital
de 15 bits
ZH
15 位数码日夜两用型摄像机
ES
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 3
9. Do not defeat the safety purpose of the polarized or grounding-type
plug. A polarized plug has two blades with one wider than the other. A
grounding type plug has two blades and a third grounding prong. Both
the wide blade and the third prong are provided for your safety. If the
supplied plug does not fit into your outlet, consult an electrician for
advice.
10. Protect the power cord from being walked on or pinched particularly at
plugs, convenience receptacles, and the point where they exit from the
equipment.
11. Only use attachments/accessories specified by the manufacturer.
12. Unplug this equipment during lightning storms or when unused for
long periods of time.
13. Refer all servicing to qualified service personnel. Servicing is required
when the equipment has been damaged in any way, such as when
power supply cord or plug is damaged, liquid has been spilled or
objects have fallen into the equipment, the equipment has been
exposed to rain or moisture, does not operate normally, or has been
dropped.
14. An all-pole mains switch with a contact separation of at least 3mm in
each pole shall be incorporated in the electrical installation of the
building.
Warning
To reduce the risk of fire or electric shock, this apparatus should
not be exposed to rain or moisture and objects filled with liquids,
such as vases, should not be placed on this apparatus.
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 4
FCC Information
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
•
Consult the dealer or an experienced radio/ TV technician for help.
Note
Any change or modification of the equipment not expressly approved by
Bosch could void the user's authority to operate the equipment. For
additional information or to speak to a representative, please contact the
Bosch Security Systems location nearest to you or visit our web site at
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 5
Introduction
The DinionXF Day/Night is a high-performance smart surveillance color
camera. It incorporates 15-bit digital signal processing for outstanding
picture performance under all lighting conditions. The DinionXF Day/Night
is easy to install and ready to use, and offers the best solution for
demanding scene conditions. Features include:
•
•
•
•
•
•
•
Day/Night camera with mechanically switching IR filter
Three pre-programmed operation modes
Noise elimination, true color reproduction
Adaptive dynamic range optimization
Bilinx™ bi-directional coaxial communications
Genlock including sub-carrier locking
Enhanced video motion detection
Type number overview
Type number
LTC
0620/11
LTC
0620/21
LTC
0620/51
LTC
0620/61
Standard
Supply voltage
CCD type
PAL
NTSC
PAL
NTSC
24 VAC or 12 VDC
230 VAC 50Hz 110 VAC 60Hz
1/2"
Type number
LTC
0495/11
LTC
0495/21
LTC
0495/51
LTC
0495/61
Standard
Supply voltage
CCD type
PAL
NTSC
PAL
NTSC
24 VAC or 12 VDC
230 VAC 50Hz 110 VAC 60Hz
1/3"
Caution
Ensure that your power supply matches the rated voltage of your
camera before installing.
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 6
Unpacking
Unpack carefully and handle the equipment with care. The packaging
contains:
•
•
•
•
•
DinionXF Day/Night camera
CS to C lens mount adapter
CCD protection cap
Spare lens connector (male)
These instructions
Note
If equipment appears to have been damaged during shipment, repack it in
the original packaging and notify the shipping agent or supplier.
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 7
Connections
Power
Low voltage versions
High voltage versions
10mm
For low voltage cameras:
•
push in the tabs to open the quick-connectors (these connections are
not polarity sensitive).
•
use AWG16 to 22 stranded wire or AWG16 to 26 solid wire; cut back
10mm (0.4") of insulation.
Composite video
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 8
Sync
Y/C
Pin
Y/C socket
1
3
4
1
2
3
4
GND Y
GND C
Y
2
C
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 9
Alarm connector
Alarm
Pin
Alarm socket
1
2
3
4
Alarm in Ground
Alarm in
Relay out contact 1
Relay out contact 2
Pin 1
Pin 4
•
•
•
Max. wire diameter AWG 22-28 for both stranded and solid
Default relay position n.o. (normally open), no alarm
Alarm output relay switching capability: Max voltage 30VAC or
+40VDC. Max 0.5 A continuous, 10VA.
•
Alarm in: TTL logic, +5V nominal, +40VDC max, DC coupled with
22kΩ pull-up to +3.3V
Alarm in: configurable as active low or active high
Max. 42V allowed between camera ground and each of the relay pins.
•
•
Lens mounting
The camera accepts CS-mount lenses. C-mount lenses can be mounted
using the lens adapter ring. DC-iris lenses are recommended for the best
picture performance. The camera automatically detects the type of lens
used and optimizes performance accordingly. A spare male lens connector
is provided.
Caution
To avoid damaging the CCD sensor when using a C-mount lens,
make sure the supplied lens adapter ring is mounted onto the
camera before mounting the lens.
Lenses weighing more than 0.5 kg (1.1lbs) must be separately
supported.
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 10
Bosch
Bosch
Pin
Video iris lens
DC iris lens
1
2
3
4
Supply (11.5V 0.5, 50mA max.)
Not used
Damp -
Damp +
Drive +
Drive -
Video signal 1Vpp 1kOhm
Ground
Note
If a short circuit is detected on the lens connector, the on-screen display
(OSD) failure message LENS SHORT CIRCUIT is shown. The lens circuit
is automatically disabled to avoid internal damage. Remove the lens
connector and check the pin connections.
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 11
Back focus adjustment
To optimize picture sharpness in both bright and low-level lighting, adjust
the back focus. Use the camera's unique Lens Wizard (see Advanced Set-
up). This ensures that the object of interest always remains in focus even
when focusing at the maximum lens opening.
When back focusing vari-focus lenses, adjust to obtain a sharp picture in
both wide-angle and tele positions for both far and near focus.
When back focusing zoom lenses, ensure the object of interest remains in
focus throughout the entire zoom range of the lens.
To adjust back focus:
1. Open the slide door at the side of the camera
2. Unlock the back focus locking button.
3. Turn the back focus adjustment as required.
4. Lock the back focus locking button.
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 12
Mounting the camera
The camera can be mounted from the top or bottom. The bottom
mounting is isolated from ground. With outdoor scenes, a DC-iris lens is
recommended.
Caution
Do not point the camera/lens into direct sunlight.
Day/Night switching
The DinionXF Day/Night Camera is equipped with a motorized IR filter.
The IR filter can be removed in low-light or IR illuminated applications.
If Auto switching mode is selected, the camera automatically switches the
filter depending on the observed light level. The switching level is
programmable. In Auto switching mode the camera prioritizes motion (the
camera gives sharp images without motion blur as long as the light level
permits) or color (the camera gives color pictures as long as the light level
permits). The camera recognizes IR illuminated scenes to prevent
unwanted switching to color mode.
There are four different methods of switching:
•
•
•
•
via the alarm input,
via Bilinx™ communication,
as part of the programmable mode profile, or
automatically, based on the observed light levels.
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 13
Advanced Set-up
The DinionXF Day/Night normally provides an optimal picture without the
need for further adjustments. However, advanced set-up options are
available for getting the best results from the camera under special
circumstances. There are two main menus; a Mode menu and an Installer
menu.
The camera has three pre-programmed operating modes that can be
selected in the Mode menu. These modes are pre-programmed by default
but you can adjust them according to your preferences. The Mode menu
allows you to select and set-up the picture enhancement functions for each
mode. If you are not happy with your changes, you can always recall the
default values for the mode.
The camera also has an Installer menu in which the installation settings
can be set.
The Mode and Installer menus have functions that can be selected
directly or submenus for more detailed set-up.
Accessing and navigating menus
Five keys, located behind the side panel, are used for navigating through
the various menus.
To access the set-up menus, press the menu/select key (center).
The main menu appears on the OSD. Use the arrow keys for navigation.
When the Bilinx™ communications link is active, the buttons on the
camera are disabled. You can also set up Bilinx™ so that the camera
buttons remain disabled even when Bilinx™ is not actively controlling the
camera. This prevents unauthorized change of the camera settings.
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 14
Menu Structure
Mode
Mode
ALC
Enhance
Color
BLC
ALC
ALC level
Shut/Gain
Peak / average
ALC speed
Shut/Gain
Shutter
Defshut
Sens up
Gain
Max. gain
Day/Night
VMD
Mode ID
Defaults
Exit
ENHANCE
Autoblack
Blacklevel
Contour
Day/Night
Switch level
Priority
IR Contrast
Mono burst
DNR
XF-dynamic
COLOR
White balance
WB speed
R-gain
G-gain
B-gain
Saturation
BLC
Area
Area
BLC
BLC level
BLC area
VMD
VMD
Area
Active
Motion
Sensitivity
DEFAULTS
Confirm
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 15
Installer
Lens Wizard
I/O
Sync
Camera ID
Defaults
Exit
Lens wizard
Lens type
Detected
Set back focus
Set level
I/O
Alarm
Sync input
Communication
Cable comp
Comp level
Alarm
Alarm in
Active
Action
Alarm out
Sync
Sync
Detected sync
V phase
H phase
Subphase
Camera ID
Camera ID
ID position
MAC address
All Defaults
Confirm
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 16
Hints for menu navigation
How to use the 5 keys
Up key
Menu/select key
Right key
Left key
Lock
Down key
•
•
Press the menu/select key to access the menus or to move to the next
or previous menu.
Press the menu/select key for approximately 1.5 seconds to open the
Installer menu.
•
•
Use the up or down keys to scroll up or down through a menu.
Use the left or right keys to move through options or to set parameters.
•
•
When in a menu, quickly pressing the menu/select key twice restores
the selected item to its factory default.
To close all menus at once from any menu, select the Exit item and
hold down the menu/select key until the menu display disappears.
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 17
Mode menu
Function
MODE
ALC
Selection
Description
1, 2, 3
Select operating mode
Select submenu
Select to access the video level control menu
Select to access the picture enhancement menu
Select to access the color control menu
ENHANCE Select submenu
COLOR
BLC
Select submenu
ON, OFF,
Select submenu
•To enable Back Light Compensation (BLC)
operation set to ON
•Select to access the BLC menu
VMD
OFF, SIL, OSD
Select submenu
•To enable Video Motion Detection (VMD)
operation set to SIL (silent) or OSD (monitor
alarm generates on-screen message)
•Select to access the VMD menu
MODE ID
10 character string Editable name for the selected mode
DEFAULTS Select submenu
Return all settings for the selected mode to
factory defaults
EXIT
Exit the menu
ALC submenu
Function
Selection
Description
ALC LEVEL -15 - 0 - +15
Adjusts the video output level
SHUTGAIN Select submenu
Select to access the Shutter and Gain control
menu
PEAK
AVERAGE
-15 - 0 - +15
Adjust the balance between peak and average
video control
ALC SPEED Slow, Medium, Fast Adjust the speed of the video level control loop.
EXIT Return to MODE menu
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 18
ALC --> Shutter/Gain submenu
Function
Selection
Description
SHUTTER
AES, FL, FIXED
•AES - auto-shutter - the camera automatically
sets the optimum shutter speed for manual iris
lenses
•FL - flickerless mode avoids interference from
light sources (recommended for use with video
iris or DC iris lenses only)
•FIXED - allows a user defined shutter speed
DEFSHUT
FIX SHUT
1/60 (1/50), 1/100,
1/120, 1/250,
1/500, 1/1000,
1/2000, 1/5000,
1/10K
Only available if SHUTTER is AES. The camera
tries to maintain the selected shutter speed as
long as the light level of the scene permits.
1/60 (1/50), 1/100,
1/120, 1/250,
1/500, 1/1000,
1/2000, 1/5000,
1/10K
Only available if SHUTTER is FIXED. Selects
shutter speed.
SENSUP
GAIN
OFF, 2x, 3x, …,10x
Selects the factor by which the sensitivity of the
camera is increased.
AGC, FIXED
•In AGC mode the camera automatically sets the
gain to the lowest possible value needed to
maintain a good picture
•In FIXED mode the gain is set at a predefined
not scene dependent value
MAXGAIN
FIXGAIN
0, 1, ... 26
0, 1, ... 26
Available in AGC mode only. Selects the
maximum value the gain can have during AGC
operation.
Available in FIXED gain operation only. Selects
the gain setting.
DAY/NIGHT Select submenu
EXIT
Select to access the day/night control menu
Return to the ALC menu
Note
If SENS UP is active, some noise or spots may appear in the picture. This
is normal camera behavior. SENS UP may cause some motion blur on
moving objects.
If the camera is in monochrome mode, all color related menu items are
disabled and cannot be accessed.
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 19
Day/Night submenu
Function
Selection
Description
DAY/NIGHT COLOR,
MONO,
• In COLOR mode the camera will always give a color image.
•In MONO mode the IR filter is removed, giving full IR
sensitivity in a monochrome image.
AUTO
•In AUTO mode the camera switches the filter depending
on the scene illumination level.
LEVEL
-15 - 0 - +15 To set the video level at which the camera switches to
monochrome operation in AUTO DAY/NIGHT mode.
PRIORITY
COLOR,
MOTION
In AUTO mode:
•COLOR: the camera gives a color image as long as the
light level permits.
•MOTION: the camera avoids motion blur as long as the
light level permits.
IR
NORMAL,
•In ENHANCED mode the camera will optimize contrast
CONTRAST ENHANCED in applications with high IR illumination levels.
•In NORMAL mode the camera will optimize contrast in
mono application with visible light illumination.
MONO
BURST
ON, OFF
•If selected OFF The Color Burst in the video signal is
switched OFF in monochrome mode of the camera.
•If selected ON the Color Burst remains active even in
Monochrome mode of the camera.
EXIT
Return to Shutter/Gain submenu.
Enhance submenu
Function
Selection
ON, OFF
Description
AUTO BLACK
Autoblack ON automatically increases the
visibility of details
BLK LEVEL
-50, ... 0, ...+50 Adjusts the black level between 0 and approx
110mV. Zero position of slider corresponds to the
factory default black level
CONTOUR
-15 - 0 - +15
Adjusts the sharpness of the picture. 0
corresponds to the default position.
DNR (dynamic
noise reduction)
AUTO, OFF
In AUTO mode the camera automatically reduces
the noise in the picture. This may cause some
motion blur on moving objects.
XF-DYN (dynamic
range enhancement)
OFF, LOW,
MID, HIGH
In XF-DYN mode the camera automatically
optimizes the contrast in the picture.
EXIT
Return to Mode menu
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 20
Color submenu
Function
Selection
Description
WHITE
BALANCE
ATW, MANUAL,
AWB HOLD
•ATW: Auto tracking white balance allows the
camera to constantly adjust for optimal color
reproduction.
•AWB HOLD: Puts the ATW on hold and saves
the color settings.
•In MANUAL mode the Red, Green and Blue gain
can be manually set to a desired position
WB SPEED Slow, Medium, Fast Adjust the speed of the white balance control
loop.
RED gain
-5 - 0 - +5
•ATW mode and AWB hold mode: adjusts the
Red gain to optimize the white point.
BLUE gain -5 - 0 - +5
•ATW mode and AWB hold mode: adjusts the B
gain to optimize around the white point.
RED
GREEN
BLUE
-50 - 0 - +50
Controls all the colors individually for manual
white balance only.
SAT
+15, … 0, … +5
Adjusts the color saturation. -15 will lead to a
monochrome image
EXIT
Return to Mode menu
Back Light Compensation (BLC) submenu
Function
Selection
Description
BLC
ON, OFF
When ON, the video level is optimized for the
selected area of the image. Parts outside this area
may be underexposed or overexposed (this is
normal).
BLC LVL
AREA
EXIT
-15,..0,..+15
BLC LEVEL adjust the balance between the
selected BLC area and its surrounding.
Select submenu
Select to access the Back Light Compensation
area menu (see selecting an area).
Return to Mode menu
Selecting an area
To set-up an area for BLC (or VMD), access the area menu by selecting the
AREA option from the BLC (or VMD) menu. Upon entering the AREA
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 21
menu, the current area is displayed with the upper left corner flashing. The
flashing corner of the image can be moved with the Up, Down, Left, Right
arrow keys. Pressing the Select key moves the flashing cursor to the
opposite corner, which can now be moved. Pressing Select again freezes
the area and exits the area menu.
Video Motion Detection (VMD) submenu
Function
Selection
Description
VMD
OFF, SIL, OSD
When VMD is enabled and the camera can
generate SIL (silent) or OSD (monitor alarm
generates on-screen message) motion alarms.
AREA
1, 2, 3, 4,
Select submenu
•It is possible to set 4 motion sensitive areas (per
MODE).
•Press SELECT to enter the area set-up menu.
ACTIVE
MOTION
SENS
ON, OFF
Every area can be enabled individually by
selecting YES.
Press SELECT to
reset indicator
Indicates the peak of measured motion in the
selected area
Use the LEFT/RIGHT keys to set the SENSitivity
for motion to the desired level. Motion above this
level triggers alarm.
EXIT
Return to Mode menu
Note
If VMD areas overlap, motion is only detected in the area with the lowest
sequence number.
Defaults submenu
Function
Selection
Description
MODE
DEFAULTS
Select to restore the factory defaults. A
confirmation screen appears. Allow 5 seconds for
the camera to optimize the picture after a mode
reset.
EXIT
Return to Mode menu
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 22
Installer Settings
Install menu
Function
Selection
Description
LENS
Select submenu
Select to optimize camera lens combination
WIZARD
I/O
Select submenu
Select submenu
Select to access the I/O functions
Select to access the synchronization functions
Select to access ID menu
SYNC
CAMERA ID Select submenu
DEFAULTS Select submenu
EXIT
Return all settings for all modes to factory defaults
Exit the menu
Install lens wizard submenu
Function
Selection
Description
LENS TYPE AUTO, MANUAL,
DCIRIS, VIDEO
In AUTO mode the camera auto detects the type
of lens used or force the camera into a mode.
DETECTED
If the LENS TYPE detection is in AUTO, the
detected lens type will be shown.
SET BACK
FOCUS
NOW
Select to force lens to its maximum opening. After
focusing the lens the object of interest remains in
focus in bright and low light conditions.
SET LVL
(Video iris lenses only). The level detector
indicator must be set to the center by adjusting
the level potentiometer on the lens, to obtain the
best picture performance.
EXIT
Return to the INSTALL menu
Adjustment procedure DC-iris Lens:
1. Unlock the back focus locking button.
2. Access the Lens Wizard menu.
3. SET BACK FOCUS NOW is highlighted in the menu.
4. Turn the back focus adjustment as required.
5. Lock the back focus locking button.
6. Exit the menu.
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 23
Adjustment procedure Manual-iris Lens:
1. Unlock the back focus locking button.
2. Adjust the lens to the maximum lens opening.
3. Turn the back focus adjustment as required.
4. Lock the back focus locking button.
Adjustment procedure Video-iris Lens:
1. Unlock the back focus locking button.
2. Access the Lens Wizard menu.
3. SET BACK FOCUS NOW is highlighted in the menu.
4. Turn the back focus adjustment as required.
5. Lock the back focus locking button.
6. Select SET LVL in the menu; the LEVEL bar appears.
7. Point the camera at the scene it will be mostly viewing.
8. Adjust the level potentiometer located on the lens until the
LEVEL bar is in the central position.
9. Exit the menu.
Note
The best performance with video iris lenses is obtained when the peak/
average potentiometer of the lens is set to either full average or full peak
matching the position of the peak/average balance in the MODE x ALC
menu.
Install I/O submenu
Function
Selection
Description
SYNC IN
75 Ohm, HIGH
Select 75 Ohm if the external sync input is not
terminated elsewhere.
COMM
ON, OFF
If OFF, Bilinx communication is disabled.
CABLE
COMP
OFF, DEFAULT,
RG59, COAX12,
COAX6
Cable compensation is used to avoid the need for
amplifiers in long distance coax connections up to
1000m (3000ft). For optimum results select the
coaxial cable type used or if unknown, DEFAULT.
COMP
LEVEL
0, 1, .. +15
Sets the level of cable compensation.
ALARM
EXIT
Select submenu
Return to the INSTALL menu
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 24
Install I/O --> Alarm submenu
Function
Selection
Description
ACTIVE
NONE, HIGH,
LOW
Selects active_HIGH or active_LOW for the alarm
input connector. Select NONE to disable alarm
switching.
ACTION
NONE, MONO,
MODE1,MODE2,
MODE3
Selects the operating mode of the camera upon
switching the alarm input.
ALARM
OUT
VMD, REMOTE, •Select VMD to close the output relay upon VMD
alarms.
DAY/NIGHT,
•Select REMOTE to make the output relay available
to remote communication devices.
FILTER MOVE
•Day/night: the alarm output relay closes if the
camera operates in monochrome mode.
•Filter move: the alarm output relay closes before the
filter starts moving (in either direction) and opens
when the video level has stabilized (2 - 3 seconds).
EXIT
Return to the I/O menu
Install sync submenu
Function
Selection
Description
SYNC
INTERNAL, LINE Select INTERNAL for free running camera operation,
LOCK, HV
LOCK,
select LINE LOCK to lock to the power supply
frequency, select HV LOCK to lock to the signal
supplied to the external sync input, select
GENLOCK to lock the subcarrier as well.
GENLOCK
DETECTED
SYNC
Shows the actual sync mode used by the camera.
VPHASE
0, 2, … 358
Adjusts the vertical phase offset (when in LINE
LOCK mode and a valid power supply frequency is
detected).
HPHASE
-25, …, 0, …
+125
Adjust the horizontal phase offset (when in EXT lock
mode and a valid input signal is detected)
SUB
PHASE
0, 2, … 358
Adjusts the sub-carrier phase offset (when in EXT
LOCK mode and a valid sub-carrier is detected).
EXIT
Return to the INSTALL menu
Note
VPHASE, HPHASE and SUB-PHASE cannot be accessed if there is no
valid locking signal.
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 25
Install ID submenu
Function
Selection
Description
CAMERA ID
Enter a 16 character camera name string. Use
LEFT/RIGHT to change position in the string, use
UP/DOWN to select the character. Use SELECT
to exit the string edit screen.
ID POS
EXIT
OFF, TOP, BOT
Select TOP to display the camera ID in the upper
left corner; select BOT for the lower left corner.
The ID string is not displayed when the OSD
menus are open.
Return to the INSTALL menu
Defaults submenu
Function
Selection
Description
ALL
DEFAULTS
Select to restore the factory defaults. A
confirmation screen appears. Allow 5 seconds for
the camera to optimize the picture after a mode
reset.
EXIT
Return to Mode menu
Camera Control Communication
This camera is equipped with a coaxial communications transceiver. In
combination with VP-CFGSFT, the camera can be adjusted from the head-
end side of the coaxial cable. All menus can be accessed remotely giving
full control of the camera. With this communication it is also possible to
disable the local keys on the camera.
To avoid loss of communication on an installed camera, the
COMMUNICATION ON/OFF selection is NOT available while using
remote control. This function can only be accessed with the camera
buttons.
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 26
Technical specification
1/2" CCD versions
Type number
LTC
0620/11
LTC
0620/21
LTC
0620/51
LTC
0620/61
Standard
PAL
NTSC
PAL
NTSC
Active pixels
752x582
768x492
752x582
768x492
Rated supply
voltage
24 VAC or 12 VDC
12-28 VAC (50/60 Hz)
11-36 VDC
230 VAC 50Hz, (/50)
110 VAC 60Hz, (/60)
Range: 100-240 VAC 10%
50/60Hz
Min illumination
< 0.18 lux
< 0.024 lux (in monochrome mode)
1/3" CCD versions
Type number
LTC
0495/11
LTC
0495/21
LTC
0495/51
LTC
0495/61
Standard
PAL
NTSC
PAL
NTSC
Active pixels
752x582
768x492
752x582
768x492
Rated supply
voltage
24 VAC or 12 VDC
12-28 VAC (50/60 Hz)
11-36 VDC
230 VAC 50Hz, (/50)
110 VAC 60Hz, (/60)
Range: 100-240 VAC 10%
50/60Hz
Min illumination
< 0.24 lux
< 0.038 lux (in monochrome mode)
All versions
Imager
Interline CCD
540 TVL
Resolution
SNR
> 50 dB
Video output
Y/C output
1 Vpp, 75 Ohm
Y: 1 Vpp
C: 0.3 Vpp
Synchronization Internal, HV-lock, Genlock or Line Lock selectable
Shutter AES (1/60 (1/50) to 1/100000), Flickerless, Fixed selectable
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 27
All versions
Day/Night
Sens Up
Auto black
AGC
Color, Mono, Auto
Adjustable from OFF to 10x
On, Off selectable (maximum level selectable up to 28dB)
AGC on or off (0 dB) selectable
XF-DYN
DNR
Automatic dynamic range enhancement level selectable
Automatic noise filtering ON/OFF selectable
Sharpness enhancement level selectable
BLC On or Off selectable, with programmable area
Contour
BLC
White balance
Automatic 2500 - 9000K (with AWB hold mode and manual mode)
Color saturation Adjustable from monochrome (0%) to 133% color
Lens Mount
ALC lens
CS compatible, C-mount compatible with supplied adapter ring
Video or DC iris auto detect
< 5 W
Power
consumption
Dimensions
Weight
58 x 66 x 122 mm (HxWxL) without lens
450g without lens
Tripod Mount
Bottom (isolated) and Top ¼" 20 UNC
-20° to 50° C
Operating
temperature
Controls
OSD with softkey operation
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
DinionXF | Installation Manual
EN | 28
Accessories
Power transformers
•
•
•
•
TC1334
120VAC, 60Hz
120VAC, 60Hz
- 24VAC, 30VA
- 15VDC, 9VA
TC120PS
TC220PSX-24
TC220PS
220-240VAC, 50/60Hz - 24VAC, 30VA
220-240VAC, 50/60Hz - 15VDC, 9VA
Interface box:
•
VP-CFGSFT
Bilinx™ communication interface box and software
Recommended lenses
Varifocal lenses:
•
•
•
•
•
•
LTC 3264/30
LTC 3274/40
LTC 3364/21
LTC 3364/31
LTC 3364/40
LTC 3374/20
1/2" DC-iris, 4.5-10mm F1.6-360
1/2" DC-iris, 7.5-75mm F2.2-360
1/3" DC-iris, 2.8-6mm F1.4-300 - IR
1/3" DC-iris, 3.5-8mm F1.4-300 - IR
1/3" DC-iris, 2.8-12mm F1.4-360
1/3" DC-iris, 5-50mm F1.4-185
Zoom lenses:
•
•
LTC 3283/20
LTC 3384/21
1/2" Video iris, 8-48mm F1.4-360
1/3" DC-iris, 6-60mm F1.4-360
Bosch Security Systems | 2004-01 | V1.0
Download from Www.Somanuals.com. All Manuals Search And Download.
Bosch Sicherheitssysteme GmbH
Ludwig-Bölkow-Allee
85521 Ottobrunn
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven
Germany
The Netherlands
© 2004 Bosch Security Systems B.V.
Subject to change. Printed in Portugal.
3122 165 23061
Download from Www.Somanuals.com. All Manuals Search And Download.
|