Replacing Control Valve
Series:
200209 – 450000
LP Gas
Download from Www.Somanuals.com. All Manuals Search And Download.
®
For assistance call 1.800.762.1142.
Steps 1-5
1. Turn your LP gas tank off, unscrew regulator and remove LP gas tank.
2. Remove the dome.
3. Remove the access panel and the igniter wire, set aside
4. Disconnect the gas line.
5. Remove the 4 screws that hold the engine to the post and remove the engine.
Replacing Control Valves Series 200209 – 450000 LP Gas 404121
2
Download from Www.Somanuals.com. All Manuals Search And Download.
®
For assistance call 1.800.762.1142.
Step 6
Remove emitter screen:
A. 200209, 200308, 200605 – remove the 4 screws using a Phillips screw driver that attach the emitter to the emitter bottom, with the
screws removed, remove the emitter.
B. 230000-235000, 450000 – you will need to use the ratchet with an extension along with the 9/16” socket and remove the nut and
washer in the bottom of the emitter. There are 3 bolts that attach the emitter to the emitter bottom Using the #8mm open end
wrench remove these bolts. Remove the emitter screen being careful not to loosen the spacer ring from the burner stud.You will
need this later. (On the 235000-45000 you may want to remove the medium and small domes but it is not necessary).
C. 233000-235020 – there are 3 bolts that hold the emitter to the emitter bottom. Using an #8mm
open end wrench remove these 3 bolts and remove the emitter.
Replacing Control Valves Series 200209 – 450000 LP Gas 404121
3
Download from Www.Somanuals.com. All Manuals Search And Download.
®
For assistance call 1.800.762.1142.
Step 7
1. Disconnect the burner supply tube from the control valve, using a 5/8” open end wrench.
Note: There is a brass nut on the top of the control valve.You must remove the brass nut.
2. Remove the 2 screws on either side of the emitter bottom.
Note: 230000 and 235000 do not have these screws.
3. Remove the burner by pulling it up. Be careful not to damage the wires on the pilot assembly.
Replacing Control Valves Series 200209 – 450000 LP Gas 404121
4
Download from Www.Somanuals.com. All Manuals Search And Download.
®
For assistance call 1.800.762.1142.
Step 8
1. Disconnect the pilot supply tube using the #10mm open end wrench.
Note: You may need to use the #12mm open end wrench to hold the pilot orifice.
2. Remove the 2 screws that hold the pilot assembly to pilot bracket.
3. Remove the pilot assembly.
Replacing Control Valves Series 200209 – 450000 LP Gas 404121
5
Download from Www.Somanuals.com. All Manuals Search And Download.
®
For assistance call 1.800.762.1142.
Step 9
Disconnect the thermal-couple
1. Remove the screw from the access panel on the rear of the valve housing.
2. Remove the access panel.
3. Using the #8 mm open end wrench remove the nut with wires coming out of it.
Note: When reinstalling the nut to the back of the control valve finger tighten plus a ꢀ turn. Do not overtighten.
4. Remove the tip switch bracket on the front of the valve housing by removing the
Phillips screw. Be careful not to damage the wires.
Replacing Control Valves Series 200209 – 450000 LP Gas 404121
6
Download from Www.Somanuals.com. All Manuals Search And Download.
®
For assistance call 1.800.762.1142.
Step 10
Disconnect the control valve
1. Remove the brass nut that holds the control valve in the valve housing using the 3/4” open end wrench
2. Remove the control valve from the valve housing
3. Remove the pilot supply tube using a #12 mm open end wrench.
Replacing Control Valves Series 200209 – 450000 LP Gas 404121
7
Download from Www.Somanuals.com. All Manuals Search And Download.
®
For assistance call 1.800.762.1142.
Step 11
Re-install pilot supply tube and the control valve:
1. Connect the pilot supply tube to the control valve
2. Place the control valve into the valve housing. Secure the valve with the brass nut and tighten.
Replacing Control Valves Series 200209 – 450000 LP Gas 404121
8
Download from Www.Somanuals.com. All Manuals Search And Download.
®
For assistance call 1.800.762.1142.
Step 12
Reinstall the thermal-couple:
1. Attach the thermal-couple to the back of the control valve in the valve housing. Finger tighten plus a 1/4 turn with
the #8mm open end wrench.
2. Reinstall the small access panel on the back of the valve housing
Replacing Control Valves Series 200209 – 450000 LP Gas 404121
9
Download from Www.Somanuals.com. All Manuals Search And Download.
®
For assistance call 1.800.762.1142.
Step 13
1. Slide the burner assembly into the valve housing.
2. Attach the burner supply tube to the top of the control valve. Do not over tighten.
3. Tighten the two screws that hold the burner in place.
Replacing Control Valves Series 200209 – 450000 LP Gas 404121
10
Download from Www.Somanuals.com. All Manuals Search And Download.
®
For assistance call 1.800.762.1142.
Step 14
1. Attach the pilot to the pilot bracket.
2. Connect the pilot supply tube to the pilot.
Replacing Control Valves Series 200209 – 450000 LP Gas 404121
11
Download from Www.Somanuals.com. All Manuals Search And Download.
®
For assistance call 1.800.762.1142.
Step 15
200209, 200308, 200605
1. Attach the emitter to the valve housing, using 3 screws.
2. Secure.
230000 - 450000
1. Place the spacer ring on the burner stud.
2. Insert the burner stud through the bottom of the emitter. Secure with washer and nut. Do not fully tighten.
3. Align the holes of the emitter with the valve housing, and secure with screws.
4. Tighten nut inside emitter.
Replacing Control Valves Series 200209 – 450000 LP Gas 404121
12
Download from Www.Somanuals.com. All Manuals Search And Download.
®
For assistance call 1.800.762.1142.
Steps 16-19
16. Attach the engine to the post
17. Burner Connections
1. Make sure the regulator valve and hose connections are securely fastened to the
burner and the tank.
2. If your unit was assembled for you, visually check the connection between the burner
pipe and orifice. Make sure the burner pipe fits over the orifice.
WARNING: Failure to inspect this connection or follow these instructions could
cause a fire or an explosion which can cause death, serious bodily injury, or
damage to property.
3. Please refer to diagram for proper installation.
4. If the burner pipe does not rest flush to the orifice, please contact 1.800.762.1142 for
assistance.
18. Attach the dome
19. Attach the LP gas tank
Replacing Control Valves Series 200209 – 450000 LP Gas 404121
13
Download from Www.Somanuals.com. All Manuals Search And Download.
®
For assistance call 1.800.762.1142.
Step 20 - IMPORTANT
Perform leak check.
WARNING
FOR YOUR SAFETY
If you smell gas -
1. Shut off gas to appliance.
2. Extinguish any open flame.
3. If odor continues, immediately call your gas supplier or your fire department.
1. Do not operate if gas leak is present. Gas leaks may cause a fire or explosion.
2.You must follow all leak-checking procedures before operating. To prevent fire or explosion hazard when testing for
a leak:
a. Always perform leak test before lighting the heater and each time the tank is connected for use.
b. No smoking. Do not use or permit sources of ignition in the area while conducting a leak test.
c. Conduct the leak test outdoors in a well-ventilated area.
d. Do not use matches, lighters, or a flame to check for leaks.
e. Do not use heater until any and all leaks are corrected.
If you are unable to stop a leak, disconnect the LP gas supply. Call a gas appliance serviceman or your local LP gas
supplier.
Replacing Control Valves Series 200209 – 450000 LP Gas 404121
14
Download from Www.Somanuals.com. All Manuals Search And Download.
®
For assistance call 1.800.762.1142.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three
parts water.
X
2. Make sure control knobs are off.
3. Turn LP gas tank ON at valve.
X
X
4. Spoon leak check solution at all “x” locations
X
X
5. If any bubbles appear turn LP gas tank OFF, reconnect and re-test. If you continue to see
bubbles after several attempts, disconnect LP gas source and contact 1.800.762.1142 for
assistance.
6. If no bubbles appear after one minute turn tank OFF, wipe away solution and proceed.
Pilot, Pilot Supply Tube and Burner Supply Tube
1. Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three parts
water.
2. Turn LP gas tank ON at valve.
3. Turn control knob on to LOW
4. Remove access panel
5. Place leak solution on pilot supply tube at the pilot and at the control valve.
6. Place leak solution on the burner supply tube.
7. If any bubbles appear turn control valve OFF, check all connection to make sure they are
tight, and retest. If you continue to see bubbles after several attempts, turn control valve off
and disconnect LP gas source and contact 1.800.762.1142 for assistance.
8. If no bubbles appear after one minute turn tank OFF, wipe away solution and proceed.
Replacing Control Valves Series 200209 – 450000 LP Gas 404121
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Blue Rhino Global Sourcing, LLC
104 Cambridge Plaza Drive, Winston-Salem, NC 27104 USA
© 2004 Blue Rhino Global Sourcing, LLC All Rights Reserved.
®
Endless Summer is a registered trademark of Blue Rhino Global Sourcing, LLC All Rights Reserved.
®
Blue Rhino is a registered trademark of Ferrellgas, L.P. All Rights Reserved.
23004500RCV-IS-100
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Bionaire Fan BQH308C U User Manual
Black Decker Oven WLBFHB User Manual
Bosch Appliances Clothes Dryer WTMC5321US CN User Manual
Bosch Appliances Water Heater ESVVT User Manual
Bose TV Mount WB135 User Manual
Broan Electric Grill PM390 User Manual
Campbell Hausfeld Nail Gun JB349500 User Manual
Canon Photo Printer BJC 4200 User Manual
Carrier Heat Pump 50QT User Manual
Casio Digital Camera EX TR15 User Manual