DISTRIBUTION AMPLIFIERS
MANUAL PART NUMBER: 400-0038-003
PRODUCT REVISION: 0
DA1913GL
1-IN, 2-OUT RGBS
DISTRIBUTION AMPLIFIER
USER’S GUIDE
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
mounting accessories like mini mount-bracket
(DA1295FC) and cables for optimum setup.
PRECAUTIONS / SAFETY WARNINGS
1
Please read this manual carefully before using your
DA1913GL Distribution Amplifier. Keep this manual
handy for future reference. These safety
instructions are to ensure the long life of your
DA1913GL and to prevent fire and shock hazard.
Please read them carefully and heed all warnings.
·
To turn off the main power, be sure to remove
the cord from power outlet. The power outlet
socket should be installed as near to the
equipment as possible, and should be easily
accessible.
·
·
Do not pull power cord or any cable that is
attached to the DA1913GL Distribution
Amplifier.
1.1 GENERAL
·
Unauthorized personnel shall not open the unit
since there are high-voltage components inside.
If the DA1913GL Distribution Amplifier is not to
be used for an extended period of time,
disconnect the power cord from the power
outlet.
·
Qualified Altinex service personnel, or their
authorized representatives must perform all
service.
1.2 SAFETY GUIDELINES FOR THE RACK-
MOUNTING OF THE DA1913GL
1.4 CLEANING
·
Unplug the DA1913GL power cord before
cleaning. Clean surfaces with a dry cloth. Never
use strong detergents or solvents such as
alcohol or thinner. Do not use a wet cloth or
water to clean the unit.
·
·
·
Maximum operating ambient temperature is 35
(degrees C).
Never restrict the air flow through the devices’
fan or vents.
1.5 FCC / CE NOTICE
When installing equipment into a rack, distribute
the units evenly. Otherwise, hazardous
conditions may be created by an uneven weight
distribution.
·
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.
·
·
Connect the unit to a properly rated supply
circuit.
Reliable Earthing (Grounding) of Rack-Mounted
Equipment should be maintained.
·
This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when the
1.3 INSTALLATION
·
For best results, place the DA1913GL
Distribution Amplifier on a flat, level surface in a
dry area away from dust and moisture.
equipment is operated in
a
commercial
·
To prevent fire or shock, do not expose this unit
to rain or moisture. Do not place the DA1913GL
Distribution Amplifier in direct sunlight, near
heaters or heat radiating appliances, or near any
liquid. Exposure to direct sunlight, smoke or
steam can harm internal components.
environment. This equipment generates, uses,
and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications. Operation
of this equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference
at his own expense.
·
·
Handle the DA1913GL Distribution Amplifier
carefully. Dropping or jarring can damage
internal components.
Do not place heavy objects on top of the
DA1913GL. If the DA1913GL is to be mounted,
to a table or wall, use only Altinex made
2
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
The DA1913GL Distribution Amplifier is a state-of-
the-art product with a video bandwidth of 350 MHz,
enabling it to remain transparent to the video signal
passing through it. Each output is individually
buffered and is not affected by other output
loading.
·
Any changes or modifications to the unit not
expressly approved by Altinex, Inc. could void
the user’s authority to operate the equipment.
ABOUT YOUR DISTRIBUTION AMPLIFIER 2
The DA1913GL is a 1-in 2-out RGBS distribution
amplifier designed to allow the connection of a
single computer or interface source to one or two
monitors or projectors. The DA1913GL also
provides ground loop isolation through the use of
differential inputs with a common mode rejection of
+/-2.0V, making it perfect for applications with
challenging power supply scenarios. A ground loop
is a type of electromagnetic interference often
caused by small, but significant differences in
ground voltage between two or more different
power sources when equipment using the different
power sources is connected by means of
video/audio inputs and outputs. A ground loop may
also be caused when high current equipment (such
as a lighting or air conditioning system) is fed from
the same power source as the display equipment.
The common mode range of the DA1913GL
Distribution Amplifier is +/-2 Volts with a video
signal of 1 Volt p-p. In most cases, a ground loop
voltage will not exceed 200-300mv, so this range is
more than enough to handle even the most severe
ground loop problems.
TECHNICAL SPECIFICATIONS
3
FEATURES/DESCRIPTION
GENERAL
DA1913GL
1
Inputs
Input Connector
Outputs
4 BNC Female
2
Output Connectors
Compatibility
Two 4 BNC Female
High resolution RGBS,
RGsB and RsGsBs,
Component, S-Video
and Composite Video
Though primarily designed to pass an RGBS signal
format through 4-BNC connectors for each
input/output, the DA1913GL can also pass RGsB,
Component Video (Y, R-Y, B-Y), S-Video (Y/C),
and Composite Video by using the appropriate
channels. The DA1913GL can pass C-Video and
S-Video simultaneously by using Red for C-Video
and Green/Blue for Chroma/Luma respectively.
The DA1913GL is typically used for permanent
installation and is supplied with a 12-inch power
cable with bare leads requiring the connection of
9V 500mA DC power. The DA1913GL does not
come with a power adapter; it has to be wired to a
power source using the bare leads.
Table 1. DA1913GL General
MECHANICAL
DA1913GL
Material
Finish
0.1” Al
Gray
Top Panel
Lexan
Height (inches)
Width (inches)
Depth (inches)
Weight (pounds)
Ship Weight (pounds)
T° Operating
T° Maximum
Humidity
3.50in (89mm)
4.56in (116mm)
0.94in (24mm)
0.6lbs (0.27kg)
2.0lbs (0.91kg)
10°C-35°C
50°C
The DA1913GL is extremely compact, allowing it to
fit nicely into tight spots. It may also be mounted to
almost any surface using optional ”L” type mini
brackets.
90% non-condensing
MTBF (calculations)
40,000 hrs
Table 2. DA1913GL Mechanical
Note: A power adapter for the DA1913GL must be
ordered separately, if required. In the United
States, the PS5502US Power Adapter can be
used, though the connector must be cut off to allow
interconnection.
ELECTRICAL
DA1913GL
Input Video Signal
Analog Signal
Impedance
Input Sync Signal
Horizontal, Vertical, & C-Sync
1.5V p-p max
75 Ohms
TTL(+/-)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
Sync on Green
-0.3V
4.1 POWER
Impedance
Output Video Signals
Analog Signal
Fall/Rise Time (ns)
Impedance
Output Sync Signal
Composite Sync
Sync on Green
10k Ohms
The DA1913GL requires the use of a 9-12V DC
500mA power supply. The DA1913GL is provided
with a hard-wired 12-inch power input cable with
bare leads on the end.
1.0V p-p/0.7V p-p
1.4
75 Ohms
4.2 MOUNTING THE DA1913GL
TTL(+/-)
-0.3V
22 Ohms
To mount the DA1913GL, Altinex offers "L" shape
mini-brackets, DA1295SX, which provide wings on
either side of the unit, allowing it to be installed on
a rack plate, furniture, or a wall.
Impedance
Frequency Compatibility
Horizontal
15-200 kHz
47-180Hz
Vertical
Minimum Video Bandwidth
Typical Video Bandwidth
Common Mode Rejection
Coupling
350 MHz @ -3dB
380 MHz @ -3dB
+/-2V (w/signal of 1V)
AC
-40dB @ 10MHz
Cross-talk
Power
External Power Adapter (AC)
Power Consumption
9V 500 mA
Table 3. DA1913GL Electrical
DESCRIPTION OF DA1913GL
4
4
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
APPLICATION DIAGRAM
5
degrade the performance of the product.
Make sure that the cables used
are coaxial cables and that all pins are in
good condition.
INSTALLING YOUR DISTRIBUTION
AMPLIFIER
6
Step 1. Make sure that the proper power supply is
After each step is completed, the unit
should now be fully operational.
being used with the unit.
The use of an incorrect power supply
can result in equipment damage not
covered by warranty.
CONGRATULATIONS! YOU ARE DONE.
If you experience any problems, please call
1-800-258-4623 or 1-714-990-2300 for
international calls.
Step 2. Connect the power supply to the unit.
The power indicator LED on the front
panel will light. This indicates that the unit
is operational.
OPERATION
7
Step 3. Connect the high resolution RGsB or
RGBS source to the DA1913GL using
coaxial cables with BNC connectors while
making sure that the colors match
The DA1913GL will operate successfully as long
as cables are attached properly and other
specifications are followed. There are no other
adjustments necessary to operate the unit
correctly.
monitors or projectors to the output(s) of
the DA1913GL. The monitors or
Then connect one or two
projectors must be scan-rate compatible
with the source signal resolution. The
DA1913GL does not affect the scan rate.
Step 4. If the image is less than perfect, check all
the connections. The unit is very reliable
and seldom will this be the cause of
malfunction. Poor quality cables may
5
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
ACCESSORIES
Model No.
8
FREQUENTLY ASKED QUESTIONS
No: Question Answer
9
Description
1
What is the
Compensation for cable
loss is automatically
made for a distance of
100 feet, though the
DA1913GL can drive
signals through longer
runs depending on the
source signal resolution
and cable quality.
It is not recommended
since one power supply
is supplied with each
unit. Please consider
the PS5581SM, a rack
mount power supply.
The DA1913GL has two
individually buffered
outputs.
The common mode
range of the DA1913GL
Distribution Amplifier is
+/-2V with a video signal
of 1V p-p. In most
cases, a ground loop
voltage will not exceed
200-300mV, so this
range is more than
RACK MOUNTING BRACKETS
Rack/Wall/Furniture Mount Mini-
brackets
(2-"L" shaped brackets)
POWER SUPPLIES
9V 500mA Power Supply for US
9V 500mA Power Supply for UK
maximum length
of cable that can
be used with the
DA1913GL?
DA1295SX
PS5502US
PS5512UK
PS5522AU
PS5532GR
PS5542JP
9V 500mA Power Supply for Australia
9V 500mA Power Supply for Germany
9V 500mA Power Supply for Japan
4 BNC to 4 BNC COAXIAL CABLE
Bulk Cable 4 coaxes (500ft minimum)
3 feet, 4 BNC to 4 BNC coaxial cable
6 feet, 4 BNC to 4 BNC coaxial cable
12 feet, 4 BNC to 4 BNC coaxial cable
25 feet, 4 BNC to 4 BNC coaxial cable
50 feet, 4 BNC to 4 BNC coaxial cable
75 feet, 4 BNC to 4 BNC coaxial cable
100 feet, 4 BNC to 4 BNC coaxial cable
150 feet, 4 BNC to 4 BNC coaxial cable
4 BNC to 4 BNC COAX (Super High
Resolution)
Bulk Cable 4 coaxes (500ft minimum)
6 feet, 4 BNC to 4 BNC coaxial cable
12 feet, 4 BNC to 4 BNC coaxial cable
25 feet, 4 BNC to 4 BNC coaxial cable
50 feet, 4 BNC to 4 BNC coaxial cable
75 feet, 4 BNC to 4 BNC coaxial cable
100 feet, 4 BNC to 4 BNC coaxial cable
2
Can I use the
DA1913GL
power supply to
power 2 units
simultaneously?
CB4100MR
CB4103MR
CB4106MR
CB4112MR
CB4125MR
CB4150MR
CB4175MR
CB41100MR
CB41150MR
3
4
Are outputs 1 & 2
buffered?
What is common
mode range of
the DA1913GL
and why is it so
important?
CB4300MR
CB4306MR
CB4312MR
CB4325MR
CB4350MR
CB4375MR
CB43100MR
enough to handle even
the most severe ground
loop problems.
5
How will the
DA1913GL
provide protection
from a ground
loop in the
A ground loop is a type
of electromagnetic
interference often
caused by small, but
significant differences in
ground voltage between
two or more different
power sources when
equipment using the
different power sources
is connected by means
of video/audio inputs
and outputs. A ground
loop may also be
system?
caused when high
6
Download from Www.Somanuals.com. All Manuals Search And Download.
DISTRIBUTION AMPLIFIERS
any way so as, in its judgment, to affect its
stability or reliability, or that has been subject to
misuse, negligence or accident.
current equipment (such
as a lighting or air
conditioning system) is
fed from the same
power source as the
display equipment.
11.2 RETURN POLICY
It is very important that you receive product that
you have ordered and that this product fulfills your
need. In the unlikely event that an Altinex product
needs to be returned please follow the procedure
below:
TROUBLESHOOTING GUIDE
10
We have carefully tested and have found no
problems in the supplied DA1913GL unit; however,
we would like to offer the following suggestions:
Altinex will accept product returns for a period of
30 days from authorized Altinex dealers. Products
must be returned in an unopened package.
·
Please make sure that input amplitude level is
as follows:
If product has been opened, the restocking fees
will apply. For the restocking fee amount, please
contact an Altinex Sales Representative.
1. Analog signal is less than 1.5V.
2. Sync signal is less than 0.3V.
·
·
·
Please use Altinex supplied external power
Supply/AC Adapter (9V, 500mA) only.
If product is in your possession for more than 30
days, the restocking fees will apply.
Please check settings of Sync Level, Video
Level and Input Termination Switches.
Altinex will not accept any returns on cables or
custom products.
Please make sure that proper quality of cables
is used. We recommend Altinex made cables for
best results.
If your product is in warranty and needs service,
contact the Altinex Sales Department for an RMA
(Return Material Authorization). Products returned
without an RMA number may experience a delay
in service.
·
If the problem shows up after continuous usage
at higher voltage, higher temperature, higher
humidity, or at other extreme environmental
conditions, please correct that the problem.
If your product is out of warranty and needs
service, contact the Altinex Sales Department for
an RMA (Return Material Authorization). Products
returned without an RMA number may experience
a delay in service. The service charges will be
quoted to you before the actual repairs are done.
ALTINEX POLICY
11
11.1 LIMITED WARRANTY
Altinex warrants that its products and cables are
free from defects in materials under normal use
and service. This warranty is limited to repairing at
company’s factory any part or parts of the product,
which upon company’s examination shall disclose
to be, thus defective. Products considered
defective should be returned to company with
transportation charges pre-paid within 2 years (90
days for cables) from date of shipment to the
purchaser. The warranty is expressly instead of all
other warranties expressed or implied. Altinex
neither assumes nor authorizes any other person
to assume for it any other liability in connection
with the sale of the products. This warranty shall
not apply to any product that shall have been
repaired or altered outside of company’s factory in
11.3 CONTACT INFORMATION
Sales Department
Phone:
Fax:
714-990-2300
714-990-3303
Accounting Department
Phone:
Fax:
714-990-6088
714-990-5778
7
Download from Www.Somanuals.com. All Manuals Search And Download.
|