Alliance Laundry Systems Washer Accessories 802715 User Manual |
Installation Instructions
for Stacked Washers and Dryers
Inside.....................................
Dimensions........................................................................
Before You Start................................................................
Installation.........................................................................
2
4
5
Installer Checklist ........................................................... Back Cover
Date Purchased ________________
Model Number ________________
Serial Number _________________
Keep these instructions for future reference.
(If this machine changes ownership, this manual must accompany machine.)
Part No. 802715
December 2006
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions
23.5 in.
(59.7 cm)
8.0 in.
(20.3 cm)
15.4 in.
(39.1 cm)
5.25 in.
(13.3 cm)
24 in.
(61 cm)
*13.1 in.
(33.3 cm)
28 in.
(71.1 cm)
26.9 in.
(68.3 cm)
*14.6 in.
(37.08 cm)
2.0 in.
(5.1 cm)
ELECTRIC DRYERS
SWD829N
* With leveling legs turned into base.
23.5 in.
(59.7 cm)
8.0 in.
(20.3 cm)
15.4 in.
(39.1 cm)
1
5.25 in.
(13.3 cm)
2.3 in.
(39.1
cm)
24 in.
(61 cm)
*13.1 in.
(33.3 cm)
28 in.
(71.1 cm)
26.9 in.
(68.3 cm)
*14.6 in.
(37.08 cm)
2.0 in.
(5.1 cm)
GAS DRYERS
SWD830N
SWD830N
*With leveling legs turned into base.
1
3/8 in. NPT Gas Connection
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
802715
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Before You Start
WARNING
Any disassembly requiring the use of
tools must be performed by a suitably
qualified service person.
Supplies
For most installations, the basic supplies you will need
are:
W299
3
1
2
NOTE: If the the unit is delivered on a cold day
(below freezing), or is stored in an unheated room
or area during the cold months, do not attempt to
operate it until the unit has had a chance to warm
up.
5
6
NOTE: Some moisture in the wash drum is normal.
Water is used during testing at the manufacturer.
4
7
8
9
DRY2023N
1
2
3
4
5
6
7
8
9
Safety Glasses
Wood Block
Power Cord (Electric Models)
Wrench
Screwdriver
Level
5/16 Inch Socket Wrench
Duct Tape
Teflon Tape (Gas Models)
Figure 1
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
802715
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Water Supply
Installation
Water supply faucets must fit standard 3/4 inch
(19.1 mm) female garden hose couplings. DO NOT
USE SLIP-ON OR CLAMP-ON CONNECTIONS.
Step 1: Position Unit Near Installation
Area
Move unit as close to the desired area of installation as
possible.
Water supply faucets should be readily accessible to
permit turning them off when washer is not being
used.
o
WARNING
Washer and dryer are not designed to be
operated as separated, side-by-side units.
Recommended cold water temperature is 60 to
o
o
o
80 Fahrenheit (16 to 27 Celsius). Recommended
hot water temperature is 120 to 140 Fahrenheit
(49 to 60 Celsius). Warm water is a mixture of hot
and cold water. Warm water temperature is dependent
upon water temperature and pressure of both the hot
and cold water supply lines.
o
o
o
o
W187
NOTE: For best performance and to minimize
vibration or movement, install washer on a solid,
sturdy and level floor. Some floors may need to be
reinforced, especially on a second floor or over a
basement. Do not install the washer on carpeting,
soft tile, a platform or other weakly supported
structures.
Water pressure must be a minimum of 20 to a
maximum of 120 pounds per square inch (138 to
827 kPa) static pressure measured at the faucet.
NOTE: Water pressure under 20 pounds per
square inch (138 kPa) will cause an extended fill
time in the washer and may not properly flush out
the detergent dispenser.
Step 2: Connect Fill Hoses
WARNING
Turn on the water faucets and flush the lines for
approximately two minutes to remove any foreign
material that could clog the screens in the water
mixing valve.
Under certain conditions, hydrogen gas
may be produced in a hot water system
that has not been used for two weeks or
more. HYDROGEN GAS IS EXPLOSIVE. If
the hot water system has not been used
for such a period and before using the
washer, turn on all hot water faucets and
let the water flow from each for several
minutes. This will release any
NOTE: When installing in newly constructed or
renovated buildings, it is very important to flush
the lines since build-up may have occurred during
construction.
accumulated hydrogen gas. The gas is
flammable. Do not smoke or use an open
flame during this time.
W029
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
802715
5
IMPORTANT: Hoses and other natural rubber
parts deteriorate after extended use. Hoses may
develop cracks, blisters or material wear from the
temperature and constant high pressure they are
subject to.
Connecting Hoses
Remove the two plain rubber washers and two filter
screens from the accessories bag. Install them into
screen must be facing outward.
All hoses should be checked on a yearly basis for
any visible signs of deterioration. Any hose showing
the signs of deterioration listed above should be
replaced immediately. All hoses should be replaced
every five years.
Screw hose couplings with the filter screens onto the
water faucets until they are finger-tight. Then, using a
pliers, screw approximately 1/4 turn.
Screw hose couplings from other end of hoses onto the
water mixing valve until they are finger-tight. Then,
using a pliers, screw approximately 1/4 turn. Refer to
IMPORTANT: Do not cross thread or overtighten
couplings. This will cause them to leak.
1
2
Turn water on and check for leaks. If leaks are found,
turn off the water, unscrew hoses and reinstall them
until there are no leaks.
WATER
MIXING VALVE
IMPORTANT: Turn off water supply whenever
there will be an extended period of non-use.
1
3
COLD
4
HOT
2
3
SWD596N
1
2
3
4
Water Faucets
5
Cold Water Connection
Hot Water Connection
Water Fill Hoses
Figure 3
4
IMPORTANT: Turn off water supply faucets after
check-out and demonstration. Owner should turn
off water supply whenever there will be an
extended period of non-use.
TLW1976N
1
2
3
4
5
Water Faucet
Fill Hose
Plain Rubber Washer
Hose Coupling
Filter Screens
NOTE: Longer fill hoses are available (as optional
equipment at extra cost) if the hoses supplied with
the washer are not long enough for the installation.
Order hoses as follows:
Figure 2
No. 20617 Fill Hose (8 feet) (2.44 m)
No. 20618 Fill Hose (10 feet) (3.05 m)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
802715
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Risers
Step 3: Connect Drain Hose to Drain
Receptacle
Risers (or air cushions) may have to be installed if the
pipes knock or pound when flow of water stops. The
risers are more efficient when installed as close as
Remove the drain hose from its shipping position on
the rear of the washer by unhooking the hose from the
retainer clamp and by removing the shipping tape.
Install the drain hose into the drain receptacle
(standpipe, wall or laundry tub) following the
instructions below.
2
IMPORTANT: Drain receptacle must be capable of
handling a minimum of 1-1/4 inch (32 cm) outside
diameter drain hose.
Standpipe Installation:
Place the drain hose into the standpipe.
Remove the beaded strap from accessories bag and
place around standpipe and drain hose and tighten
will prevent the drain hose from dislodging from drain
receptacle during use.
1
W005I
1
2
Water Supply Faucets
Risers (Air Cushions)
1
Figure 4
24 in. to 36 in.
(61 to 91.44 cm)
Recommended
Height
2
3
SWD598N
1
2
3
Drain Hose
Beaded Tie-Down Strap
Standpipe 2 in. (5.08 cm) or 1-1/2 in. (4 cm)
Figure 5
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
802715
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Wall Installation:
Laundry Tub Installation:
For installations of this type, the drain hose MUST be
secured to one of the fill hoses using the beaded strap
For this type of installation, the drain hose MUST be
secured to the stationary tub to prevent hose from
beaded strap (supplied in accessories bag) to secure
hose.
NOTE: End of drain hose must be below 24 in.
(61 cm).
1
1
2
3
2
SWD600N
H023I
1
2
Drain Hose
Tie-Down Strap (tape if necessary)
1
2
3
Drain Hose
Beaded Strap (tape if necessary)
Fill Hoses
Figure 7
Figure 6
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
802715
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 4: (Gas Dryer Only) Connect Gas
Supply Pipe
Natural Gas Altitude Adjustments
Altitude
Orifice Size
inches
0.0890
Part No.
feet
3000
6000
8000
9000
10,000
m
No.
43
44
45
46
47
mm
2.26
2.18
2.08
2.06
1.99
WARNING
915
503778
58719
1830
2440
2740
3050
0.0860
To reduce the risk of gas leaks, fire or
explosion:
• The dryer must be connected to the type
of gas as shown on nameplate located in
the door recess.
0.0820
503779
503780
503781
0.0810
0.0785
Table 1
• Use a new flexible stainless steel
connector.
• Use pipe joint compound insoluble in L.P.
(Liquified Petroleum) Gas, or Teflon tape,
on all pipe threads.
• Purge air and sediment from gas supply
line before connecting it to the dryer.
Before tightening the connection, purge
remaining air from gas line to dryer until
odor of gas is detected. This step is
required to prevent gas valve
contamination.
2. Remove the shipping cap from the gas
connection at the rear of the dryer. Make sure you
do not damage the pipe threads when removing
the cap.
3. Connect to gas supply pipe.
NOTE: When connecting to a gas line, an
equipment shut-off valve must be installed within
6 feet (1.8 m) of the dryer. An 1/8 in. NPT pipe plug
must be installed as shown for checking inlet
• Do not use an open flame to check for gas
leaks. Use a non-corrosive leak detection
fluid.
1
• Any disassembly requiring the use of
tools must be performed by a suitably
qualified service person.
W316
5
1. Make certain your dryer is equipped for use with
the type of gas in your laundry room. Dryer is
equipped at the factory for Natural Gas with a
3/8 inch NPT gas connection.
2
3
NOTE: The gas service to a gas dryer must
conform with the local codes and ordinances, or in
the absence of local codes and ordinances, with the
latest edition of the National Fuel Gas Code ANSI
Z223.1/NFPA 54 or the CAN/CGA-B149, National
Gas Installation Code.
4
D434I
1
New stainless steel flexible connector -
(Use design CSA certified connector)
Use only if allowed by local codes
1/8 in. NPT Pipe Plug
Equipment Shut-Off Valve
Black Iron Pipe Shorter than 20 ft. (6.1 m) -
Use 3/8 in. (9.5 mm) pipe
3
3
Natural Gas, 1000 Btu/ft (37.3 MJ/m ) service must
be supplied at 6.5 1.5 inch water column pressure.
2
3
4
For proper operation at altitudes above 3000 feet
(915 m) the natural gas valve spud orifice size must be
reduced to ensure complete combustion. Refer to
5
3/8 in. NPT Gas Connection
Figure 8
4. Tighten all connections securely. Turn on gas and
check all pipe connections (internal & external)
for gas leaks with a non-corrosive leak detection
fluid.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
802715
9
NOTE: The dryer and its appliance main gas valve
must be disconnected from the gas supply piping
system during any pressure testing of that system
at test pressures in excess of 1/2 psi (3.45 kPa).
Refer to Step 12 (Check Heat Source).
Grounding Information
• This dryer must be connected to a grounded
metal, permanent wiring system; or an
equipment-grounding conductor must be run
with the circuit conductors and connected to the
equipment-grounding terminal or lead on the
dryer.
3
L.P. (Liquefied Petroleum) Gas, 2500 Btu/ft
3
(93.1 MJ/m ) service must be supplied at 10 1.5 inch
water column pressure.
• The dryer has its own terminal block that must be
connected to a separate branch, 60 Hertz, single
phase circuit, AC (alternating current) circuit,
fused at 30 Amperes (the circuit must be fused
on both sides of the line). Electrical service for
the dryer should be of maximum rated voltage
listed on the nameplate. Do not connect dryer
to 110, 115, or 120 volt circuit.
For proper operation at altitudes above 3000 feet
(915 m) the L.P. gas valve spud orifice size must be
reduced to ensure complete combustion. Refer to
L.P. Altitude Adjustments
Altitude
feet
Orifice Size
inches
Part No.
m
No.
55
mm
1.32
1.18
• Heating elements are available for field
installation in dryers which are to be connected to
electrical service of different voltage than that
listed on nameplate, such as 208 Volt.
3000
8000
915
2440
0.0520
58755
56
0.0465
503786
Table 2
• If branch circuit to dryer is 15 feet (4.57 m) or
less in length, No. 10 AWG wire (copper wire
only), or as required by local codes. If over
15 feet (4.57 m), use No. 8 AWG wire (copper
wire only), or as required by local codes. Allow
sufficient slack in wiring so dryer can be moved
from its normal location when necessary.
NOTE: DO NOT connect the dryer to L.P. Gas
Service without converting the gas valve. Install
L.P. Gas Conversion Kit 649P3, available at extra
cost.
Step 5: (Electric Dryer Only) Connect
Electrical Plug
• The power cord connection between wall
receptacle and dryer terminal block IS NOT
supplied with dryer. Type of power cord and
gauge of wire must conform to local codes.
Dryer requires 120/240 Volt or 120/208 Volt, 60 Hertz,
3 or 4 wire electrical suppy. Refer to serial plate for
specific electrical requirements.
NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.
WARNING
To reduce the risk of fire, electric shock,
serious injury or death, all wiring and
grounding MUST conform with the latest
edition of the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local
regulations as might apply. It is the
customer’s responsibility to have the wiring
and fuses installed by a qualified electrician
to make sure adequate electrical power is
available to the dryer.
W521
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
802715
10
Connecting Power Cord with Three-Wire Plug
NOTE: Four-wire cord is required for mobile
homes or where codes do not permit grounding
through neutral.
NOTE: The power cord is NOT supplied with the
electric dryer. Type of power cord and gauge of wire
must conform to local codes and instructions.
POWER SUPPLY
POWER SUPPLY
1
The method of wiring the dryer is optional and subject
to local code requirements.
2
3
NOTE: Connect the dryer to the power supply with the
MAXIMUM RATED VOLTAGE listed on the nameplate.
A typical
INTERMEDIATE
FUSE BOX (may
be omitted if
service entrance
box is fused)
30-Amp
Three-Wire
Receptacle
NEMA Type
10-30R
INTERMEDIATE
SHUT-OFF BOX
(may or may not
be fused)
4
WALL
RECEPTACLE
5
120 12
V.A.C.
120 12
V.A.C.
6
240 12
V.A.C.
7
L1 L2
POWER CORD CONNECTION
L1 L2
DIRECT CONNECTION
NOTE: Use COPPER WIRE only.
Shorter than 15 ft. (4.5 m) – use 10 AWG
Longer than 15 ft. (4.5 m) – use 8 AWG
D816I
1
3 Wire Grounded Neutral 120/240 Volt, 60 Hertz
AC 1 Phase Service Entrance Switch Box
(Refer to NOTE above)
4
Metallic or Non-Metallic Sheathed Cable
(Copper Wire Only)
5
6
7
Power Cord (Not supplied with dryer)
Neutral
Terminal Block in Dryer
2
3
30 Ampere Fuses or Circuit Breaker
Neutral Wire
Figure 9
1. Disconnect power to dryer.
3. Use a strain relief and insert end of power cord
through power supply hole.
2. Remove access cover from rear of dryer.
D696I
D695I
Figure 11
Figure 10
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
802715
11
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Use the three screws from the accessories bag to
attach the power cord wires to the terminal block.
Connecting Power Cord with Four-Wire Plug
NOTE: Four-wire cord is required for mobile
homes or where codes do not permit grounding
through neutral.
1
2
2
1
3
4
3
D286I
240 12
0
1
2
3
“L1” Terminal
Neutral Terminal
“L2” Terminal
V.A.C.
V.A.C.
Figure 12
DRY2016N
5. Tighten all screws firmly.
1
2
3
4
Typical Four-Wire Receptacle
Power Cord – Not Supplied with Dryer
Strain Relief Nut
IMPORTANT: Failure to tighten these screws
firmly may result in wire failure at the terminal
block.
Strain Relief
6. Secure the strain relief to the power cord, or
wires, where they enter the dryer cabinet.
Figure 13
1. Disconnect power to dryer.
7. Check the continuity of the ground connection
before plugging the cord into an outlet. Use an
acceptable indicating device connected to the
center grounding pin of the plug and the green
screw on the back of the cabinet.
2. Remove access cover from rear of dryer.
8. Reinstall access cover and screw.
D695I
Figure 14
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
802715
12
3. Remove ground screw and save for use in Step 5.
Remove wire and use in Step 6.
5. Attach power cord ground (green) wire to rear
bulkhead using ground screw removed in Step 3.
1
1
7
6
5
2
4
D697I
1
Ground Screw
Figure 15
3
DRY1920N
1
2
3
4
5
6
7
White
“L2” Terminal
Black
Green
Red
4. Use a strain relief and insert end of power cord
through power supply hole.
Neutral Terminal
“L1” Terminal
Figure 17
6. Use the three screws from the accessories bag to
attach the remaining power cord wires to the
terminal block as follows:
a. Red wire to “L1” terminal.
b. Black wire to “L2” terminal.
c. White wire to Neutral terminal.
D696I
Figure 16
NOTE: When installing the white wire, loop the
free eyelet end of the ground wire (removed in
Step 3) and attach along with the white wire to the
neutral (center) terminal on the terminal block.
7. Tighten all screws firmly.
IMPORTANT: Failure to tighten these screws
firmly may result in wire failure at the terminal
block.
8. Secure the strain relief to the power cord, or
wires, where they enter the dryer cabinet.
9. Check the continuity of the ground connection
before plugging the cord into an outlet. Use an
acceptable indicating device connected to the
center grounding pin of the plug and the green
screw on the back of the cabinet.
10. Reinstall access cover and screw.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
802715
13
• Locate dryer so exhaust duct is as short as
Step 6: Connect Dryer Exhaust System
possible.
• Be certain old ducts are cleaned before installing
WARNING
your new dryer.
• Use 4 inch (102 mm) diameter rigid or flexible
To reduce the risk of fire and combustion
gas accumulation the dryer MUST be
exhausted to the outdoors.
metal duct.
• The male end of each section of duct must point
W604
away from the dryer.
To reduce the risk of fire and the
• Use as few elbows as possible.
accumulation of combustion gases, DO NOT
exhaust dryer air into a window well, gas
vent, chimney or enclosed, unventilated
area, such as an attic, wall, ceiling, crawl
space under a building or concealed space
• Use duct tape or pop-rivets on all duct joints. DO
NOT use sheet metal screws or fasteners on
exhaust pipe joints which extend into the duct.
• Ductwork that runs through unheated areas must
be insulated to help reduce condensation and lint
build-up on pipe walls.
of a building.
W045
• In mobile home installations, dryer exhaust duct
WARNING
must be secured to mobile home structure.
• Dryer exhaust duct MUST NOT terminate under
This gas appliance contains or produces a
chemical or chemicals which can cause
death or serious illness and which are
known to the State of California to cause
cancer, birth defects, or other reproductive
harm. To reduce the risk from substances in
the fuel or from fuel combustion, make sure
this appliance is installed, operated, and
maintained according to the instructions in
mobile home.
• Dryer exhausts 220 cfm (measured at back of
dryer).
• DO NOT install flexible duct in concealed
spaces, such as a wall or ceiling.
• Static pressure in exhaust duct should not be
greater than .6 inches water column (1.5 cm),
measured with manometer placed on exhaust
duct two feet (61 cm) from dryer (check with
dryer running and no load).
this manual.
W115
To reduce the risk of fire, DO NOT use
plastic or thin foil ducting to exhaust the
• Exhausting dryer in hard-to-reach locations can
be done by installing 521P3 Flexible Metal Vent
Kit (available as optional equipment at extra
cost).
dryer.
W354
• DO NOT use plastic or thin foil ducting. Rigid
• Sufficient make-up air must be supplied to
replace the air exhausted by the dryer. The free
area of any opening for outside air must be at
2
2
least 40 in. (260 cm ).
• Failure to exhaust dryer properly will void
warranty.
NOTE: Venting materials are not supplied with the
dryer (obtain locally).
IMPORTANT: DO NOT block the airflow at the
bottom of the dryer’s front panel with laundry,
rugs, etc. Blockage will decrease airflow through
the dryer, thus reducing the efficiency of the dryer.
DON’T
DO
SWD449N
Figure 18
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
802715
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Exhaust Direction
Exhaust System
The dryer can be exhausted to the outdoors through the
back, left, right or bottom of the dryer. EXCEPTION:
Gas dryers cannot be vented out the left side
because of the burner housing.
For best drying results, recommended maximum
To prevent backdraft when dryer is not in operation,
outer end of exhaust pipe must have a weather hood
with hinged dampers (obtain locally).
Dryer is shipped from factory ready for rear exhaust.
Exhausting the dryer through sides or bottom can be
accomplished by installing a Directional Exhaust Kit,
528P3, available as optional equipment at extra cost.
NOTE: Weather hood should be installed at least
12 inches (30.5 cm) above the ground. Larger
clearances may be necessary for installations where
heavy snowfall can occur.
Weather Hood Type
Number of
90° Elbows
Recommended
Use Only for Short Run installations
4 in.
(10.2 cm)
D673I
4 in.
(10.2 cm)
D802I
2-1/2 in.
(6.35 cm)
Maximum length of 4 in. (10.2 cm) diameter rigid metal duct.
0
1
2
3
4
65 feet (19.8 m)
55 feet (16.8 m)
47 feet (14.3 m)
36 feet (11.0 m)
28 feet (8.5 m)
55 feet (16.8 m)
47 feet (14.3 m)
41 feet (12.5 m)
30 feet (9.1 m)
22 feet (6.7 m)
Maximum length of 4 in. (10.2 cm) diameter flexible metal duct.
0
1
2
3
4
45 feet (13.7 m)
35 feet (10.7 m)
30 feet (9.1 m)
25 feet (7.6 m)
20 feet (6.1 m)
35 feet (10.7 m)
27 feet (8.2 m)
21 feet (6.4 m)
17 feet (5.2 m)
15 feet (4.5 m)
NOTE: Deduct 6 feet (1.8 m) for each additional elbow.
Table 3
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
802715
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 7: Position and Level the Unit
Position unit so it has sufficient clearance for
C
D
E
E
A
B
Dryer and Exhaust Duct Clearances
Description
Area
A
Minimum Clearance
0 in. (0 cm)
Left Dryer Side
Right Dryer Side
Dryer Top
B
1 in. (2.54 cm)
6 in. (15.24 cm)
4 in. (10.2 cm)
2 in. (5.1 cm)
C
D
Dryer Rear
E
Exhaust Duct Clearance to Combustible Materials
NOTE: Shaded areas indicate adjacent structure.
SWD795N
Figure 19
NOTE: Use of the dispenser drawer or unit doors
as a handle in the transportation of the unit may
cause damage to the dispenser or doors.
Place unit in position on a solid, sturdy and level floor.
Installing the unit on any type of carpeting, soft tile, a
platform or other weakly supported structures is not
recommended.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
802715
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Place a level on the cabinet top and check if the unit is
level from side to side and front to back.
NOTE: Level must rest on raised portion of top
1
5
1
4
3
SWD832N
1
Wood Block
Figure 21
2
SWD833N
1
2
3
4
5
Level
Make sure that the unit does not rock. When unit is
level and does not rock, tighten locknuts securely
against bottom of unit base. If these locknuts are not
tight, unit will move out of position during operation.
Rubber Foot
Leveling Leg
Locknut
Unit Base
Leveling legs can be adjusted from inside the unit with
a 7/8 inch deep well socket. All four legs must rest
firmly on the floor so the weight of the unit is evenly
distributed. The unit must not rock and must be level
from side-to-side and front-to-back.
Figure 20
If unit is not level, tilt unit to access the front and rear
leveling legs. For easier access to leveling legs, prop
Loosen the locknuts and adjust legs by screwing into
or out of unit base.
NOTE: Do not slide unit across floor once the
leveling legs have been extended. Legs and base
could become damaged.
Place rubber feet (supplied in accessories bag) on all
Verify that unit does not rock.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
802715
17
IMPORTANT: DO NOT tip washer more than
6 inches (152.4 mm) in any direction after shipping
brace has removed. Shock absorbers may separate
and damage to unit may result. For leveling
purposes, the unit may be tilted a maximum of
6 inches (152.4 mm) in any direction.
Step 8: (Washer Only) Remove the Shock
Sleeves and Shipping Brace
Remove front access panel by removing the two
screws at the bottom of the panel.
Remove the five bolts and lockwashers from shipping
brace with 9/16 inch wrench and remove brace. Refer
and one is holding the brace to the weight. Remove all
four shock sleeves by pulling on the yellow rope.
Step 9: Wipe Out Inside of Washer Drum
and Dryer Drum
Before using the washer and dryer for the first time,
use an all-purpose cleaner, or a detergent and water
solution, and a damp cloth to remove shipping dust
from inside the drums.
IMPORTANT: The shipping brace, bolts,
lockwashers and shock sleeves should be saved and
MUST be reinstalled whenever the unit is moved
more than 4 ft. (1.22 m). Do not lift or transport
unit from front or without shipping materials
installed. Refer to the Washer User’s Guide for
proper instructions on reinstalling the shipping
materials.
Store the shipping materials in the accessories bag.
Save materials for use whenever the unit is moved.
Remove label from front side of front access panel and
place on back side of front access panel for future
reference.
SWD834N
Figure 23
1
2
3
4
FLW2048N
1
2
3
4
Shock Sleeves
Motor Mount
Hooked End of Shipping Brace
Bolts and Lockwashers
SWD603N
Figure 24
Figure 22
Reinstall front access panel.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
802715
18
The dryer is designed to be operated on a separate
branch, polarized, three-wire, effectively grounded,
120 Volt, 60 Hertz, AC (alternating current) circuit
protected by a 15 Ampere fuse, equivalent fusetron or
circuit breaker.
Step 10: Plug In the Washer and Dryer
Electric Dryer
Connect the dryer to an electrical power source. Refer
to Step 4 for information on connecting power cord.
The three-prong grounding plug on the power cord
should be plugged directly into a polarized three-slot
effectively grounded receptacle rated 120 Volts AC
determine correct polarity of the wall receptacle.
Grounding Information
The dryer must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current. The dryer is equipped
with a cord having an equipment-grounding conductor
and a 3 prong grounding plug. The three-prong
grounding plug on the power cord should be plugged
directly into a polarized three-slot effectively
grounded receptacle rated 110/120 Volts AC
(alternating current) 15 Amps.
Connect to 30 Amp circuit.
D275I
Figure 25
Gas Dryer
Dryer requires 120 Volt, 60 Hertz electrical supply and
comes equipped with a 3-prong grounding plug. Refer
to serial plate for specific electrical requirements.
WARNING
NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.
This dryer is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged
directly into a properly grounded three-
prong receptacle. Do not cut or remove the
grounding prong from this plug.
WARNING
To reduce the risk of fire, electric shock,
serious injury or death, all wiring and
grounding MUST conform with the latest
edition of the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local
W036
WARNING
regulations as might apply. It is the
Improper connection of the equipment-
grounding conductor can result in a risk of
electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the dryer is properly
customer’s responsibility to have the wiring
and fuses installed by a qualified electrician
to make sure adequate electrical power is
available to the dryer.
W521
grounded.
W038
When plugging in the dryer:
• Do not overload circuits.
• Do not use an adapter.
Do not modify the plug provided with the dryer – if it
will not fit the outlet, have a proper outlet installed by
a qualified electrician.
• Do not use an extension cord.
NOTE: Have a qualified electrician check the
polarity of the wall receptacle. If a voltage reading
is measured other than that illustrated, the
qualified electrician should correct the problem.
• Do not operate both a washer and gas dryer on
the same circuit. Use separetely fused 15 amp
circuits.
Do not operate other appliances on the same circuit
when this appliance is operating.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
802715
19
Washer
WARNING
Washer requires 120 Volt, 60 Hertz electrical supply
and comes equipped with a 3-prong grounding plug.
Refer to serial plate for specific electrical
requirements.
To reduce the risk of an electric shock or
fire, DO NOT use an extension cord or an
adapter to connect the dryer to the electrical
power source.
NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.
W037
2
3
1
2
1
3
120 12
V.A.C.
0 V.A.C.
120 12
V.A.C
0 V.A.C
4
5
120 12
V.A.C.
120 12
V.A.C
Standard 120 Volt, 60 Hertz
3-Wire Effectively
Grounded Circuit
4
DRY2022N
1
2
3
4
5
L1
Ground
Neutral Side
Round Grounding Prong
Neutral
5
Plug cord into separately fused 15 Amp circuit.2
Figure 27
DRY2022N
1
2
3
4
5
“L1”
Ground
Neutral
Neutral Side
Round Grounding Prong
WARNING
To reduce the risk of fire, electric shock,
serious injury or death, all wiring and
grounding MUST conform with the latest
edition of the National Electrical Code,
ANSI/NFPA No. 70, and such local
regulations as might apply. It is the
customer’s responsibility to have the
wiring, fuses and circuit breakers
Figure 26
installed by a qualified electrician to make
sure adequate electrical power is
available to the washer.
W518
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
802715
20
When plugging in the washer:
• DO NOT overload circuits.
• DO NOT use an extension cord.
• DO NOT use an adapter.
NOTE: Have a qualified electrician check the
polarity of the wall receptacle. If a voltage reading
qualified electrician should correct the problem.
WARNING
• DO NOT operate both a washer and gas dryer on
the same circuit. Use separately fused 15 Amp
circuits.
This unit is equipped with a three-prong
(grounding) plug for your protection
against shock hazard and should be
plugged directly into a properly grounded
three-prong receptacle. Do not cut or
remove the grounding prong from this
The washer is designed to be operated on a separate
branch, polarized, three-wire, effectively grounded,
120 Volt, 60 Hertz, AC (alternating current) circuit
protected by a 15 Amp fuse, equivalent fusetron or
circuit breaker.
plug.
W213
The three-prong grounding plug on the power cord
should be plugged directly into a polarized three-slot
effectively grounded receptacle rated 110/120 Volts
AC (alternating current) 15 Amps. Refer to Figure 27
to determine correct polarity of the wall receptacle.
Step 11: Recheck steps 1-10
Refer to Installer Checklist on the back cover of this
manual and make sure that unit is installed correctly.
Run washer through one complete cycle to make sure
it is operating properly.
WARNING
Step 12: Check Heat Source
To reduce the risk of an electric shock or
fire, DO NOT use an extension cord or an
adapter to connect the washer to the
Electric Dryers
Close the loading door and start the dryer in a heat
setting (refer to the Dryer User’s Guide supplied with
the unit). After the dryer has operated for three
minutes, the exhaust air or exhaust pipe should be
warm.
electric power source.
W082
Grounding Information
The washer must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current.
Gas Dryers
IMPORTANT: This operation is to be conducted
by qualified personnel only.
The washer is equipped with a cord having an
equipment-grounding conductor and a 3-prong
grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and
grounded in accordance with all local codes and
ordinances.
To view the burner flame, remove the lower front
panel of the dryer.
Close the loading door, start the dryer in a heat setting
(refer to the Dryer User’s Guide supplied with the
unit); the unit will start, the igniter will glow red and
the main burner will ignite.
WARNING
IMPORTANT: If all air is not purged out of gas
line, gas igniter may go off before gas is ignited. If
this happens, after approximately two minutes
igniter will again attempt gas ignition.
Improper connection of the equipment-
grounding conductor can result in a risk
of electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the washer is
IMPORTANT: If igniter does not light, make sure
gas is turned on.
properly grounded.
W216
Do not modify the plug provided with the washer – if
it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
802715
21
After the dryer has operated for approximately five
minutes, observe burner flame through lower front
panel. Adjust the air shutter to obtain a soft, uniform
blue flame. (A lazy, yellow-tipped flame indicates lack
of air. A harsh, roaring, very blue flame indicates too
much air.) Adjust the air shutter as follows:
WARNING
For personal safety, lower front panel must
be in place during normal operation.
W046
1. Loosen the air shutter lockscrew.
After the dryer has operated for approximately three
minutes, exhaust air or exhaust pipe should be warm.
2. Turn the air shutter to the left to get a luminous
yellow-tipped flame, then turn it back slowly to
the right to obtain a steady, soft blue flame.
3. After the air shutter is adjusted for proper flame,
tighten the air shutter lockscrew securely.
4. Reinstall the lower front panel.
1
2
4
3
D702I
1
2
Air Shutter Lockscrew
Appliance Main Gas Valve
3
4
Air Shutter
1/8 in. (3.1 mm) Pipe Plug
(For checking manifold pressure)
Figure 28
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
802715
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installer Checklist
Fast Track for Installing the Unit
(Refer to the manual for more detailed information)
• Position Unit Near
Installation Area.
1
2
7
• Position and
Level the Unit.
CHECK
• Connect Fill
Hoses.
SWD833N
COLD
Plain
Washers
CHECK
HOT
Filter
Screen
Washer Only
8
• Remove the Shock
Sleeves and
Shipping Brace.
TLW1976N
CHECK
3
4
• Connect Drain
Hose to Drain
Receptacle.
FLW2048N
FLW2048N
CHECK
9
• Wipe Out Inside of Washer
and Dryer.
CHECK
S
W
D598N
SWD603N
SWD834N
Gas Only
CHECK
• Connect Gas Supply Pipe.
• Check for Gas Leaks.
10 • Plug In Washer and Dryer.
CHECK
D434I
D275I
D254I
ELECTRIC DRYERS
GAS DRYERS AND WASHERS
Electric Only
5
6
• Connect Electrical
Cords.
CHECK
11 • Recheck Steps 1-10.
D679IE0A
D679IEOA
CHECK
CHECK
12 • Check Heat
• Connect Dryer Exhaust
System.
Source.
D702I
CHECK
CHECK
SWD449N
Download from Www.Somanuals.com. All Manuals Search And Download.
|