0710
RY-ES
External Signaling Relay
- INSTALLATION & OPERATION INSTRUCTIONS -
The RY-ES is a relay used to activate an external signaling device when the door station calls in. It
can be used for call extension on the JK, JF, JA, KC, KB, AX, NEM, DB, and IE systems. The relay
connects to the chime output of the master in place of the IER-2. The system’s power supply
powers the input of the RY-ES relay. A separate power source is required for the external device.
1
NAMES & FUNCTIONS
Input of relay:
Red: Positive Power
Black: Negative Power
White: Activation wire*
Blue: Activation wire*
*Blue & White are Non-polarized
RY-ES
Output of relay:
2 Orange wires
N/O Dry contact closure
2
INSTALLATION
RY-ES
Wall mount the unit with the
supplied mounting hardware as
shown in the diagram to the left.
When making wire connections,
be sure not to short any wires
together. Use wire nuts or
another protective material to
isolate the connections.
Pg. 1
Download from Www.Somanuals.com. All Manuals Search And Download.
3
WIRING DIAGRAMS (cont)
KB & KC Systems
KB-3MRD/
KC-1GRD
Door
A1
A2
1A1
1A2
B1
B2
PS-2420UL
+
-
+
-
NP
Blue
S
S
White
Red
External Device
and Power
RY-ES
Orange
Black
AX System
POWER
DOOR RELEASE RELAY
L8
L1 L2 L3 L4 L5 L6 L7
VIDEO OUT
V1
V2
M1 M3
RS-232C
D1
D2
D3
D4
D5
D6
D7
D8
VCH1 VCH2
M2
M4
Cat5e
+ -
D-PS
+ -
V-PS
X1 OUT X2
AX-320C
CO
AIPHONE AX-084C
AX-8M/AX-8MV
PS-2420UL
Cat5e
-
+
Orange
Yellow
PS-2420UL
-
+
Black
Red
External Device
and Power
Orange
White
Blue
RY-ES
NP
Pg. 3
Download from Www.Somanuals.com. All Manuals Search And Download.
3
WIRING DIAGRAMS (cont)
NEM System
NA-A
NEM-10/C
A
B
1
~
C
D/E
10
E
S
+
NP
White
Blue
External Device
and Power
Orange
RY-ES
Red
+
-
Black
-
PS-2420UL
DB System
IE System
IE Door
Station
IE-1GD
IE-2AD
DB-1MD
DA-1DS
D
E
L
D
E
D1
E1
(D2)
(E2)
1
2
B1
B2
B3
L
B4
T
R
C
E
BL+
BL-
Org
Yel
White
Blue
15V
Orange
RY-ES
Red
~
~
Black
Blue
White
Red
PT-1210N
RY-ES
Orange
External Device
and Power
+
-
~
~
Black
~ ~
PT-1211C
External Device
and Power
4
SPECIFICATIONS
Power Source:
Current consumption:
12-24V DC, 12-16V AC. Power supplied by master.
DC: Standby 10mA. Max 120mA
AC: Standby 15mA. Max 140mA
125V AC 1.0A
Contact rating:
30V DC 1.0A
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
Pg. 4
RY-ES Instr.
0710JD
TOLL FREE TECHNICAL SUPPORT: (800) 692-0200
FAX (425) 455-0071
E-MAIL: [email protected]
Download from Www.Somanuals.com. All Manuals Search And Download.
|