Aiphone Intercom System RY ES User Manual

0710  
RY-ES  
External Signaling Relay  
- INSTALLATION & OPERATION INSTRUCTIONS -  
The RY-ES is a relay used to activate an external signaling device when the door station calls in. It  
can be used for call extension on the JK, JF, JA, KC, KB, AX, NEM, DB, and IE systems. The relay  
connects to the chime output of the master in place of the IER-2. The system’s power supply  
powers the input of the RY-ES relay. A separate power source is required for the external device.  
1
NAMES & FUNCTIONS  
Input of relay:  
Red: Positive Power  
Black: Negative Power  
White: Activation wire*  
Blue: Activation wire*  
*Blue & White are Non-polarized  
RY-ES  
Output of relay:  
2 Orange wires  
N/O Dry contact closure  
2
INSTALLATION  
RY-ES  
Wall mount the unit with the  
supplied mounting hardware as  
shown in the diagram to the left.  
When making wire connections,  
be sure not to short any wires  
together. Use wire nuts or  
another protective material to  
isolate the connections.  
Pg. 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
WIRING DIAGRAMS (cont)  
KB & KC Systems  
KB-3MRD/  
KC-1GRD  
Door  
A1  
A2  
1A1  
1A2  
B1  
B2  
PS-2420UL  
+
-
+
-
NP  
Blue  
S
S
White  
Red  
External Device  
and Power  
RY-ES  
Orange  
Black  
AX System  
POWER  
DOOR RELEASE RELAY  
L8  
L1 L2 L3 L4 L5 L6 L7  
VIDEO OUT  
V1  
V2  
M1 M3  
RS-232C  
D1  
D2  
D3  
D4  
D5  
D6  
D7  
D8  
VCH1 VCH2  
M2  
M4  
Cat5e  
+ -  
D-PS  
+ -  
V-PS  
X1 OUT X2  
AX-320C  
CO  
AIPHONE AX-084C  
AX-8M/AX-8MV  
PS-2420UL  
Cat5e  
-
+
Orange  
Yellow  
PS-2420UL  
-
+
Black  
Red  
External Device  
and Power  
Orange  
White  
Blue  
RY-ES  
NP  
Pg. 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
WIRING DIAGRAMS (cont)  
NEM System  
NA-A  
NEM-10/C  
A
B
1
~
C
D/E  
10  
E
S
+
NP  
White  
Blue  
External Device  
and Power  
Orange  
RY-ES  
Red  
+
-
Black  
-
PS-2420UL  
DB System  
IE System  
IE Door  
Station  
IE-1GD  
IE-2AD  
DB-1MD  
DA-1DS  
D
E
L
D
E
D1  
E1  
(D2)  
(E2)  
1
2
B1  
B2  
B3  
L
B4  
T
R
C
E
BL+  
BL-  
Org  
Yel  
White  
Blue  
15V  
Orange  
RY-ES  
Red  
~
~
Black  
Blue  
White  
Red  
PT-1210N  
RY-ES  
Orange  
External Device  
and Power  
+
-
~
~
Black  
~ ~  
PT-1211C  
External Device  
and Power  
4
SPECIFICATIONS  
Power Source:  
Current consumption:  
12-24V DC, 12-16V AC. Power supplied by master.  
DC: Standby 10mA. Max 120mA  
AC: Standby 15mA. Max 140mA  
125V AC 1.0A  
Contact rating:  
30V DC 1.0A  
Aiphone Communication Systems  
1700 130th Ave. N.E.  
Bellevue, WA 98005  
(425) 455-0510  
Pg. 4  
RY-ES Instr.  
0710JD  
TOLL FREE TECHNICAL SUPPORT: (800) 692-0200  
FAX (425) 455-0071  
Download from Www.Somanuals.com. All Manuals Search And Download.  

AEG Water Heater 8000038784_00_BAL_de User Manual
Airlink101 Network Router ASW324V2 User Manual
Alpine Stereo Amplifier MRA F350 User Manual
AMX Network Card RDM 2ZC User Manual
Aspire Digital DVD Player AD N820B User Manual
Avet Reels Fishing Equipment EX 4 01 User Manual
Badger Basket Washer Dryer 09980 User Manual
Beckett Water Gardening Outdoor Fountain PL1322 User Manual
Beko Clothes Dryer DPY 7504 XB1 User Manual
Beko Clothes Dryer OIF 22300 User Manual