| BARD MANUFACTURING COMPANY, INC.   QW2S-QW5S Water-to-Air H/P   Engineering Specification Guide   1.0 GENERAL   Furnish and install a self-contained, vertical, floor standing, heat pump to   be manufactured by Bard Manufacturing Company, Inc. The unit shall be   approved and Listed by Intertek ETL Listed (ETL US/C). Unit shall be   factory assembled, pre-charged, pre-wired, tested and ready to operate.   Unit performance shall be AHRI Certified in accordance with ISO Standard   13256-1:1998 “Water to Air and Brine to Air Heat Pumps”, which includes   watt allowance for water pumping. Unit shall include 5 year parts warranty   covering compressor, parts, and heat exchange coils, subject to terms and   conditions of Bard Limited Warranty Agreement.   Unit efficiency shall be specified in terms of EER and COP.   Manufacturers: Capacities shall be as indicated on drawings and units   shall be manufactured by Bard Manufacturing Company, Inc. or prior   approved equal.   2.0 CONSTRUCTION FEATURES   2.1 CABINET   Constructed of 20 gauge pre-painted or vinyl laminated galvanized   steel. Choices available are either two-tone (vinyl) finish with “slate”   front panels and “platinum” cabinet for designer appearance, (gray)   or (beige) painted steel (select one). Vinyl finish is very resistant to   scratching and marring and is easy to clean. Tamper resistant   fasteners are provided for access panels. Unit includes built-in   rollers for each installation into wall sleeve and removal for service,   if necessary. Front panel is hinged and lockable for filter service and   access to primary functional electrical controls.   2.2 INSULATION   Cabinet is fully insulated with foil covered, high-density fiberglass   insulation with sealed edge treatment and special sound deadening   insulation material in the compressor section. All insulation is   designed to resist mold and mildew growth and facilitate ease of   cleaning.   F1915 (2012 04)   Page 1 of 6   Download from Www.Somanuals.com. All Manuals Search And Download.   standard. One shall be used for fresh water applications, the other   for protected (antifreeze) closed systems. The factory wired switch is   for fresh water.   Phase rotation protection and phase failure protection shall be   standard factory installed features on all equipment with three-phase   power. If unit is wired incorrectly phase monitor will lock out   compressor operation and red warning light shall energize. Once   power wiring is corrected at field power wiring location, a green light   will energize on phase monitor. If a phase of power is lost, the phase   monitor will also lock out.   2.9 SERVICE FEATURES   The unit shall include a diagnostic light to indicate when service is   required. System Service shall detect high or low-pressure control   operation.   3.0 LOOP MODULE PUMPING SYSTEM   All models shall be designed with mounting and wiring provisions   for field installed pump module option, when unit is applied with   ground loop system.   4.0 VENTILATION OPTIONS (Select One)   Q-Tec models are designed to provide optional ventilation packages to   meet all of your ventilation and indoor air quality requirements. All   ventilation packages are factory installed.   4.1 BAROMETRIC FRESH AIR DAMPER   STANDARD   The barometric fresh air damper is a standard feature on all models.   It allows outside ventilation air, up to 25% of the total airflow rating   of the unit, to be introduced through the air inlet openings and to be   mixed with the conditioned air. The damper opens during blower   operation and closes when the blower is off. Adjustable blade stops   allow different amounts of outside air to be introduced into the   building and can be easily locked closed if required.   4.2 BLANK OFF PLATE   OPTIONAL   A blank off plate covers the air inlet openings, which restrict any   outside air from entering the unit. The blank off plate should be   utilized in applications where outside air is not required to be mixed   with the conditioned air.   4.3 COMMERCIAL ROOM VENTILATOR   OPTIONAL   F1915 (2012 04)   Page 3 of 6   Download from Www.Somanuals.com. All Manuals Search And Download.   The built-in commercial room ventilator (CRV) is internally mounted   and allows outside ventilation air, up to 50% of the total air flow   rating of the unit, to be introduced through the air inlet openings. The   CRV shall be modular and easily added or removed from the unit   cabinet. It includes a built-in exhaust air damper. The damper can   be easily adjusted to control the amount of fresh air supplied into the   building. The CRV can be controlled by indoor blower operation or   field controlled based on room occupancy. Unit complies with   ANSI/ASHRAE Standard 62.1 Ventilation for Acceptable Air Quality.   Two Models Available: Spring Return on Power Loss or   Deactivation - Vent Option V   Power Return (will not close on power loss)   – Vent Option P   4.4 ENERGY RECOVERY VENTILATOR   OPTIONAL   The Energy Recovery Ventilator (ERV) shall consist of 1 or 2 rotary   wheels in an insulated cassette frame with seals, drive motor and   belt. The ERV assembly shall also include intake and exhaust   blowers. The entire assembly shall easily slide in or out of the unit   cabinet, allowing for maintenance or replacement. The total energy   wheel shall be coated with silica gel desiccant, permanently bonded   without the use of binders or adhesives. The coated segments shall   be washable with detergent or alkaline coil cleaner and water.   Desiccant shall not dissolve or deliquesce in the presence of water   or high humidity. All diameter and perimeter seals shall be provided   as part of the cassette assembly and shall be factory set. Drive belts   shall not require external tensioners or adjustment. Cassette wheels   shall include rims to prevent belts from slipping off wheels. Intake   and exhaust blowers shall have selections of high, medium or low   speed and selected independently, to allow for positive   pressurization if desired. The ERV cassette including parts and   media shall include 5year warranty subject to terms and conditions   of Bard’s warranty.   The ERV thermal performance shall be certified by the manufacturer   in accordance with ASHRAE Standard 84, Method of Testing Air-to   Air Heat Exchangers and ARI Standard 1060, Rating for Air-to-Air   Energy Recovery Ventilation Equipment Cassettes, and shall be   listed in the ARI Certified Products. Unit complies with   ANSI/ASHRAE Standard 62.1 Ventilation for Acceptable Air Quality.   . 5.0 FILTER OPTIONS - (Select One)   F1915 (2012 04)   Page 4 of 6   Download from Www.Somanuals.com. All Manuals Search And Download.   5.1 2” Fiberglass – Pleated – MERV 8   6.0 HOT GAS REHEAT- (Factory installed option)   6.1 The dehumidification circuit incorporates an independent heat   exchanger coil in the supply air stream in addition to the standard   evaporator coil. This coil reheats the supply air after it passes over   the cooling coil, and is sized to nominally match the sensible cooling   capacity of the evaporator coil.   Extended run times in   dehumidification mode can be achieved using waste heat from the   refrigeration cycle to achieve the reheat process, while at the same   time large amounts of moisture can be extracted from the passing air   stream.   7.0 CABINET COLOR – (Select One)   7.1 Washable Vinyl- Two-Tone Finish with Slate front and platinum sides   7.2 Slate Gray   7.3 Beige   9.0 CONTROLS – (Select one of the following factory mounted   control options)   9.1 None   9.2 Electronic non-programmable, manual changeover   9.3 Electronic programmable, auto changeover   9.4 Electronic programmable, auto changeover, with dehumidistat   9.5 Electronic non-programmable, auto changeover, with humidistat   10.0 ACCESSORIES   10.1 WALL SLEEVE   Wall sleeve shall be factory supplied and must be constructed of 16   gauge-galvanized steel, coated with an epoxy primer and baked-on   polyester enamel paint. It shall be designed to withstand a minimum   of 1000 hours of salt spray protection when tested per ASTM B117-03   standard. One sleeve size fits all models. Sleeve only required when   a ventilation option is selected.   10.2 Exterior Louver   Furnish factory louver designed for condenser air and outside air   F1915 (2012 04)   Page 5 of 6   Download from Www.Somanuals.com. All Manuals Search And Download.   intake and exhaust. Louver shall have a powder coat finish.   See our color chart for color selections. Louver required with sleeve   with the use of any ventilation option.   10.4 AIR DISTRIBUTION – (Select 1)   10.3.1   10.3.2   The Q-Tec shall have a discharge air plenum with   double deflection register mounted on front.   The Q-Tec shall have a discharge air plenum with   double deflection supply register on the front and both   sides.   10.3.3   The Q-Tec shall be ducted with a cabinet extension to   cover ductwork   11.0 WARRANTY   11.1 The Bard product specified shall be free from defects in materials   and workmanship for a period of 5 years for compressor, and for a   period of 5 years for all parts. Warranty period shall start from date   of installation as stated on warranty card; or from date of shipment if   no warranty card is returned to Bard Manufacturing. Equipment   must be used under normal conditions and warranty is subject to   Bard Manufacturing’s standard limited warranty statement.   12.0 INSTALLATION   12.1 Installation shall be done in strict adherence to Bard’s Installation   Instructions.   F1915 (2012 04)   Page 6 of 6   Download from Www.Somanuals.com. All Manuals Search And Download.   |