		 22P Vertical Type   
					TS1-2GSDOM22V   
					SATA Flash Modules   
					Description   
					Features   
					With a 7P Signal + 15P Power SATA interface, high   
					speed and low power consumption, SATA Flash   
					Modules is perfect replacement storage device for   
					PCs, Laptops, gaming systems, and handheld   
					devices.   
					• 
					• 
					RoHS compliant   
					Fully compatible with devices and OS that support the   
					SATA 1.0a 1.5Gbps standard   
					• 
					Non-volatile Flash Memory for outstanding data   
					retention   
					• 
					• 
					Supports up to Ultra DMA Mode 4   
					Placement   
					Built-in ECC (Error Correction Code) functionality and   
					wear-leveling algorithm ensures highly reliable of data   
					transfer   
					• 
					• 
					• 
					7P Signal + 15P Power male SATA connector   
					Lower Power Consumption   
					Shock resistance   
					Dimensions   
					Side   
					A 
					Millimeters   
					45.80 ± 0.40   
					33.00 ± 0.50   
					7.08 ± 0.20   
					Inches   
					1.803 ± 0.016   
					1.299 ± 0.020   
					0.279 ± 0.008   
					B 
					C 
					1 
					Transcend Information Inc.   
					V1.1   
				22P Vertical Type   
					TS1-2GSDOM22V   
					SATA Flash Modules   
					Reliability   
					Built-in 4 symbol/page correction ECC   
					Data Reliability   
					Data Retention   
					Connector Durability   
					10 years   
					10,000 times   
					Performance   
					Model P/N   
					Read (KB/s)   
					Write (KB/s) Random Read (KB/s) Random Write (KB/s)   
					17519 47123 4598   
					49636   
					2GB SATA Flash Module   
					* Note : 25 ℃, according to 7+15 pins combo connector test on GA-8IG1000MK, 256 MB RAM, IDE interface support   
					UDMA4, Windows® XP Version 2002 SP2, benchmark utility HDBENCH (version 3.4006), copied file 100MB   
					Actual Capacity   
					Model P/N   
					Capacity   
					C/H/S   
					Capacity (BIOS) DOS Format (Bytes) Windows Format (Bytes)   
					2GB SATA Flash   
					Module   
					2GB   
					3884 / 16 / 63   
					2004MB   
					2,003,697,664   
					2,003,697,664   
					* Note: FAT format   
					Regulations   
					Compliance   
					CE, FCC and BSMI   
					3 
					Transcend Information Inc.   
					V1.1   
				22P Vertical Type   
					TS1-2GSDOM22V   
					SATA Flash Modules   
					Pin Assignments   
					Pin No.   
					Pin Name   
					Pin No.   
					Pin Name   
					01   
					03   
					05   
					07   
					09   
					11   
					13   
					15   
					17   
					19   
					21   
					GND   
					A-   
					02   
					04   
					06   
					08   
					10   
					12   
					14   
					16   
					18   
					20   
					22   
					A+   
					GND   
					B+   
					B-   
					GND   
					NC   
					NC   
					NC   
					GND   
					GND   
					5V   
					GND   
					5V   
					5V   
					GND   
					GND   
					NC   
					GND   
					NC   
					NC   
					Pin Layout   
					Pin out   
					01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22   
					4 
					Transcend Information Inc.   
					V1.1   
				22P Vertical Type   
					TS1-2GSDOM22V   
					SATA Flash Modules   
					Block Diagram   
					D00 ~ D07   
					-CE0, -CE2…   
					Others   
					Flash Memory   
					Data bus   
					D0 – D7   
					-CE0   
					-CE1   
					Data   
					bus   
					Control   
					Signal   
					SATA   
					Bridge   
					IDE   
					-WE…-RE   
					Flash Disk   
					Controller   
					Power   
					Power   
					Flash Memory   
					D10 ~ D17   
					D0 – D7   
					-CE0   
					-CE1, -CE3…   
					-CE1   
					-WE…-RE   
					DC Characteristics   
					Parameter   
					Symbol   
					Min.   
					Max.   
					5.5   
					Unit   
					Remark   
					Supply Voltage   
					VCC   
					VOH   
					VOL   
					VIH   
					2.97   
					V 
					High level output voltage   
					VCC – 0.8   
					V 
					Low level output voltage   
					0.8   
					V 
					V 
					2.4   
					Non-schmitt trigger   
					Schmitt trigger1   
					High level input voltage   
					2.05   
					V 
					VIL   
					0.6   
					1.25   
					141   
					172   
					V 
					Non-schmitt trigger   
					Schmitt trigger1   
					Low level input voltage   
					V 
					Pull up resistance2   
					RPU   
					RPD   
					52.7   
					47.5   
					KOhm   
					kOhm   
					Pull down resistance   
					5 
					Transcend Information Inc.   
					V1.1   
				22P Vertical Type   
					TS1-2GSDOM22V   
					SATA Flash Modules   
					Command Set   
					Command   
					Code   
					E5 or 98h   
					90h   
					FR   
					– 
					SC   
					– 
					SN   
					– 
					CY   
					– 
					DH   
					Y 
					LBA   
					– 
					Status   
					Support   
					Note   
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					Check Power Mode   
					Execute Drive Diagnostic   
					Erase Sector   
					– 
					– 
					– 
					– 
					Y 
					– 
					Support   
					Not Support   
					Support   
					Support   
					Support   
					Support   
					Support   
					Support   
					C0h   
					– 
					Y 
					– 
					Y 
					– 
					Y 
					– 
					Y 
					Y 
					– 
					#3   
					Flush Cache   
					E7h   
					– 
					Y 
					Format Track   
					50h   
					– 
					Y 
					– 
					– 
					Y 
					– 
					Y 
					Y 
					– 
					Identify Device   
					Idle   
					ECh   
					– 
					– 
					Y 
					E3h or 97h   
					E1h or 95h   
					91h   
					– 
					Y 
					– 
					– 
					– 
					Y 
					– 
					Idle Immediate   
					Initialize Drive Parameters   
					– 
					– 
					– 
					Y 
					– 
					– 
					Y 
					– 
					– 
					Y 
					– 
					Key Management   
					Structure Read   
					B9 (Feature   
					0-127)   
					10   
					11   
					12   
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					– 
					– 
					– 
					NOT Support #1   
					NOT Support #1   
					NOT Support #1   
					Key Management Read   
					Keying Material   
					B9 (Feature   
					80)   
					Key Management Change   
					Key Management Value   
					B9 (Feature   
					81)   
					13 NOP   
					00h   
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					Y 
					– 
					– 
					– 
					– 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					– 
					– 
					NOT Support   
					Support   
					14 Read Buffer   
					15 Read DMA   
					E4h   
					C8h   
					Y 
					Y 
					Y 
					Y 
					Y 
					– 
					Y 
					Y 
					Y 
					Y 
					Y 
					– 
					Y 
					Y 
					Y 
					Y 
					Support   
					16 Read Long Sector   
					17 Read Multiple   
					18 Read Sector(s)   
					19 Read Verify Sector(s)   
					20 Recalibrate   
					22h or 23h   
					C4h   
					NOT Support #2   
					Support   
					Y 
					Y 
					Y 
					– 
					20h or 21h   
					40h or 41h   
					1Xh   
					Support   
					Y 
					Support   
					– 
					Support   
					21 Request Sense   
					03h   
					– 
					– 
					– 
					– 
					– 
					Not Support   
					Support   
					#3   
					22   
					Security Disable Password F6h   
					– 
					– 
					– 
					– 
					Y 
					23 Security Erase Prepare   
					24 Security Erase Unit   
					25 Security Freeze Lock   
					26 Security Set Password   
					F3h   
					F4h   
					F5h   
					F1h   
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					Y 
					Y 
					Y 
					Y 
					– 
					– 
					– 
					– 
					Support   
					Support   
					Support   
					Support   
					6 
					Transcend Information Inc.   
					V1.1   
				22P Vertical Type   
					TS1-2GSDOM22V   
					SATA Flash Modules   
					27 Security Unlock   
					28 Seek   
					F2h   
					– 
					– 
					Y 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					Y 
					– 
					– 
					Y 
					– 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					– 
					Y 
					– 
					Support   
					Support   
					Support   
					Support   
					Support   
					Support   
					Support   
					7Xh   
					29 Set Feature   
					EFh   
					– 
					30 Set Multiple Mode   
					31 Set Sleep Mode   
					32 Standby   
					C6h   
					Y 
					– 
					– 
					– 
					– 
					E6h or 99h   
					E2 or 96h   
					E0 or 94h   
					87h   
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					33 Standby Immediate   
					34 Translate Sector   
					35 Wear Level   
					– 
					– 
					– 
					– 
					Y 
					– 
					Y 
					– 
					Y 
					– 
					Y 
					– 
					Not Support   
					Support   
					#3   
					#4   
					F5h   
					36 Write Buffer   
					E8h   
					– 
					– 
					– 
					– 
					Support   
					37 Write DMA   
					CAh   
					Y 
					– 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Y 
					Support   
					38 Write Long Sector   
					39 Write Multiple   
					40 Write Multiple w/o Erase   
					41 Write Sector(s)   
					42 Write Sector(s) w/o Erase   
					43 Write Verify   
					32h or 33h   
					C5h   
					Not Support   
					Support   
					#2   
					#3   
					#3   
					Y 
					Y 
					Y 
					Y 
					Y 
					CDh   
					Not Support   
					Support   
					30h or 31h   
					38h   
					Not Support   
					Support   
					3Ch   
					#1: This command is optional, depending on the key Management scheme in use.   
					#2: Use of this command is not recommended.   
					#3: CFA feature set command is not supported by P-ATA to S-ATA bridge controller.   
					#4: If Security command 22~27 are supported, this command is not supported.   
					Definitions   
					FR = Features Register   
					SC =Sector Count register (00H to FFH, 00H means 256 sectors)   
					SN = Sector Number register   
					CY = Cylinder Low/High register   
					DH = Head No. (0 to 15) of Drive/Head register   
					LBA = Logic Block Address Mode Support   
					– = Not used for the command   
					Y = Used for the command   
					7 
					Transcend Information Inc.   
					V1.1   
				22P Vertical Type   
					TS1-2GSDOM22V   
					SATA Flash Modules   
					SMART Command Set   
					ꢀSMART Command Set   
					SMART Feature Register Values   
					D0h   
					D1h   
					D2h   
					D3h   
					Read Data   
					D4h   
					D8h   
					D9h   
					DAh   
					Execute OFF-LINE Immediate   
					Enable SMART Operations   
					Read Attribute Threshold   
					Enable/Disable Autosave   
					Save Attribute Values   
					Disable SMART Operations   
					Return Status   
					1. If reserved size is below the Threshold, the status can be read from Cylinder register by Return Status command   
					(DAh).   
					ꢀSMART Data Structure   
					BYTE   
					0-1   
					F / V   
					X 
					Decription   
					Revision code   
					2-361   
					362   
					X 
					Vendor specific   
					V 
					Off line data collection status   
					363   
					X 
					Self-test execution status byte   
					364-365   
					366   
					V 
					Total time in seconds to complete off-line data collection activity   
					X 
					Vendor specific   
					367   
					F 
					Off-line data collection capability   
					368-369   
					370   
					F 
					SMART capability   
					F 
					Error logging capability   
					7-1 Reserved   
					0 1=Device error logging supported   
					371   
					X 
					F 
					F 
					F 
					R 
					F 
					V 
					V 
					V 
					Vendor specific   
					372   
					Short self-test routine recommended polling time (in minutes)   
					373   
					Extended self-test routine recommended polling time (in minutes)   
					374   
					Conveyance self-test routine recommended polling time (in minutes)   
					375-385   
					386-395   
					396   
					Reserved   
					Date Code   
					Number of MU in device (0~n)   
					MU number   
					397+(n*6)   
					398+(n*6)   
					MU data block   
					8 
					Transcend Information Inc.   
					V1.1   
				22P Vertical Type   
					TS1-2GSDOM22V   
					SATA Flash Modules   
					400+(n*6)   
					401+(n*6)   
					402+(n*6)   
					511   
					V 
					V 
					V 
					V 
					MU spare block   
					Init. Bad block   
					Last Defect Bad block ( Newest state)   
					Data structure checksum   
					F=the content of the byte is fixed and does not change.   
					V=the content of the byte is variable and may change depending on the state of the device or   
					the commands executed by the device.   
					X=the content of the byte is vendor specific and may be fixed or variable.   
					R=the content of the byte is reserved and shall be zero.   
					* 4 Byte value : [MSB] [2] [1] [LSB]   
					9 
					Transcend Information Inc.   
					V1.1   
				22P Vertical Type   
					TS1-2GSDOM22V   
					SATA Flash Modules   
					Ordering Information   
					TS XG SDOM XX   
					Connector type   
					7H = 7pin SATA horizontal   
					22V = 22pin SATA vertical   
					Transcend Product   
					22H = 22pin SATA   
					horizontal   
					Capacity:   
					SATA Flash Module   
					1G-2G   
					1. The above technical information is based on industry standard data and has been tested to be reliable. However,   
					Transcend makes no warranty, either expressed or implied, as to its accuracy and assumes no liability in   
					connection with the use of this product. Transcend reserves the right to make changes to the specifications at any   
					time without prior notice.   
					2. For specific capacity, performance, and reliability requirement, please contact with sales.   
					USA   
					Los Angeles:   
					E-mail: [email protected]   
					Maryland:   
					E-mail: [email protected]   
					
					CHINA   
					E-mail: [email protected]   
					
					TAIWAN   
					GERMANY   
					E-mail: [email protected]   
					
					No.70, XingZhong Rd., NeiHu Dist., Taipei, Taiwan, R.O.C   
					TEL +886-2-2792-8000   
					Fax +886-2-2793-2222   
					E-mail: [email protected]   
					
					HONG KONG   
					E-mail: [email protected]   
					
					JAPAN   
					E-mail: [email protected]   
					
					THE NETHERLANDS   
					E-mail: [email protected]   
					
					United Kingdom   
					E-mail: [email protected]   
					
					10   
					Transcend Information Inc.   
					V1.1   
				 |