HP Hewlett Packard Hewlett Packard Computer Accessories hp OpenView storage management appliance software User Manual

application notes  
hp OpenView  
storage management appliance  
software  
event code definitions  
Product Version: 2.0  
First Edition (December 2002)  
Part Number: AA-RTDKA-TE  
This document describes the event codes used in notification messages generated by the HP OpenView Storage  
Management Appliance software V2.0.  
Additional information and other HP OpenView documentation are available at:  
 
Application Notes Contents  
Application Notes Contents  
These Application Notes provide listings of the various event codes displayed by the HP  
OpenView Storage Management Appliance. The event codes are defined and discussed in the  
following sections:  
Intended Audience  
This document is intended for customers who purchase the Storage Management Appliance  
software V2.0. It has been developed for use by storage and system administrators who are  
experienced with:  
Managing storage area networks (SANs).  
Running a Storage Management Appliance.  
Related Storage Management Appliance Software V2.0 Documentation  
The following list includes documentation related to the Storage Management Appliance  
software V2.0:  
HP OpenView Storage Management Appliance Software V2.0 Update Installation Card  
HP OpenView Storage Management Appliance Software V2.0 User Guide  
HP OpenView Storage Management Appliance Software V2.0 Release Notes  
HP OpenView Storage Management Appliance Software V2.0 Installing Antivirus and  
Backup Software Application Notes  
HP OpenView Storage Management Appliance Software V2.0 Online Help  
HP OpenView Automation Manager Script Development Guide  
HP StorageWorks HSG Element Manager User Guide  
HP StorageWorks HSV Element Manager User Guide  
HP StorageWorks SAN Design Reference Guide  
Additional documentation, including white papers and best practices documents, is available  
from the HP website at:  
.
Storage Management Appliance Software Event Code Definitions Application Notes  
3
Introduction  
Introduction  
The Storage Management Appliance can generate notification messages to any number of  
users in response to events. A notification message, including the source of the event, date,  
time, event code, and event description, can be sent to a standard e-mail address or to an e-mail  
pager address. This document provides a complete list of the events logged by the Storage  
Management Appliance.  
The lists of events are presented in tables with one table for each application or vendor.  
Each table contains the following columns:  
Event ID—Numeric code used to identify the event specific to the event’s source.  
Event Code—Hexadecimal code used to identify an event type in notification messages  
and in the Storage Management Appliance Event Log or Audit Log.  
Severity—Single digit code indicating the event severity or potential impact on Storage  
Management Appliance operations (see Table 1 for more information).  
Description—Text describing the event. Event details are provided by the source of the  
event. In this document, event details are expressed as %1, %2, etc.  
Table 1 describes the severity codes used for event codes.  
Table 1: Severity Codes  
Event Severity  
Code  
Name  
Unknown  
Other  
Description  
Severity cannot be determined.  
0
1
Can be one of several possible severity conditions.  
Refer to the event code description for details.  
2
3
4
Information  
Warning  
Minor  
Event is generally part of normal operation.  
Further action is optional  
Further action is required but the situation is not  
considered serious.  
5
6
Major  
Action should be taken immediately.  
Critical  
Action required to avoid a significant impact on  
operations.  
7
Fatal  
An error occurred and no action can be taken to avoid  
or mitigate the immediate impact.  
4
Storage Management Appliance Software Event Code Definitions Application Notes  
 
Storage Management Appliance Event Codes  
Storage Management Appliance Event Codes  
The Storage Management Appliance’s core services—discovery, event notification, and  
automation—generate the events listed below. The system records these events in the Storage  
Management Appliance Event Log.  
Table 2: Storage Management Appliance Event Codes  
Event  
ID  
Event  
Code  
Severity  
Description  
202  
203  
204  
205  
206  
408  
880A00CA  
880A00CB  
880A00CC  
880A00CD  
880A00CE  
880A0198  
2
2
2
2
2
3
Discovery %1 started.  
Discovery %1 completed.  
New device found: %1.  
Device %1 unreachable for %2 day(s).  
Device %1 unreachable for %2 week(s).  
Notification for user %1 has been disabled. This user was the sole  
recipient of event notifications from %2.  
700  
880A02BC  
2
Received a SNMP Trap from %1. The enterprise OID is %2,  
GenericTrap is %3, SpecificTrap is %4.  
701  
702  
703  
704  
800  
880A02BD  
880A02BE  
880A02BF  
880A02C0  
880A0320  
3
6
3
6
7
The Management Appliance event log is 80% full.  
The Management Appliance event log is full.  
The Management Appliance audit log is 80% full.  
The Management Appliance audit log is full.  
Automation Manager experienced the following abnormal  
operation: %1  
801  
802  
880A0321  
880A0322  
7
2
Automation Manager experienced the following database failure:  
%1  
Event process %1 ran in policy %2 on Management Appliance %3  
completed with state %4. Process started on %5 and ended on %6  
with %7 return code. Policy finished with status: %8  
803  
804  
880A0323  
880A0324  
2
3
Event process %1 ran in policy %2 triggered on an event %3  
logged by %4.  
Event process %1 ran in policy %2 on Management Appliance %3  
completed with state %4. Process started on %5 and ended on %6  
with %7 return code. Policy finished with status: %8  
805  
806  
880A0325  
880A0326  
2
3
Action process %1 ran in policy %2 on Management Appliance %3  
completed with state %4. Process started on %5 and ended on %6  
with %7 return code. Policy finished with status: %8  
Action process %1 ran in policy %2 on Management Appliance %3  
completed with state %4. Process started on %5 and ended on %6  
with %7 return code. Policy finished with status: %8  
807  
808  
880A0327  
880A0328  
2
2
%1 policy has been submitted successfully.  
Event process %1 in policy %2 was satisfied when the %3 value of  
enterprise OID %4 was received in a SNMP Trap.  
1014  
1015  
1016  
1017  
880A03F6  
880A03F7  
880A03F8  
880A03F9  
2
2
2
2
%1 service started.  
%1 service stopped.  
%1 service: Handler not installed.  
%1 service: Bad service request.  
Storage Management Appliance Software Event Code Definitions Application Notes  
5
 
Storage Management Appliance Audit Codes  
Storage Management Appliance Audit Codes  
The Storage Management Appliance generates audits in response to most user-initiated  
operations. Activities such as creating or running a discovery generate audits that are recorded  
in the Storage Management Appliance Audit Log.  
Table 3: Storage Management Appliance Audit Codes  
Event ID Event Code Severity  
Description  
Installation of %1 on appliance %2.  
Removal of %1 from appliance %2.  
Deletion of %1 device.  
100  
101  
150  
151  
152  
207  
208  
209  
210  
211  
212  
213  
300  
8C0A0064  
8C0A0065  
8C0A0096  
8C0A0097  
8C0A0098  
8C0A00CF  
8C0A00D0  
8C0A00D1  
8C0A00D2  
8C0A00D3  
8C0A00D4  
8C0A00D5  
8C0A012C  
2
2
2
2
2
2
2
2
2
2
2
2
2
Launch of %1 URL.  
Modification of %1 device.  
Creation of discovery named %1.  
Deletion of discovery named %1.  
Modification of discovery named %1.  
Enabling of schedule for discovery named %1.  
Disabling of schedule for discovery named %1.  
Discovery named %1 requested to start.  
Discovery named %1 requested to stop.  
Creation of remote access entry for Host: %1, Application:  
%2, Domain Name: %3, Username: %4.  
301  
302  
8C0A012D  
8C0A012E  
2
2
Modification of remote access entry for Host: %1,  
Application: %2, Domain Name: %3, Username: %4.  
Deletion of remote access entry for Host: %1, Application:  
%2, Domain Name: %3, Username: %4.  
303  
304  
305  
306  
307  
308  
309  
310  
311  
312  
400  
401  
402  
403  
404  
405  
8C0A012F  
8C0A0130  
8C0A0131  
8C0A0132  
8C0A0133  
8C0A0134  
8C0A0135  
8C0A0136  
8C0A0137  
8C0A0138  
8C0A0190  
8C0A0191  
8C0A0192  
8C0A0193  
8C0A0194  
8C0A0195  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Modification of %1 license.  
Creation of %1 license.  
Deletion of %1 license.  
Modification of %1 license.  
Download of %1 license.  
Clearing of %1 license.  
Download of event log.  
Clearing of event log.  
Modification of event log properties.  
Acknowledgement of events in the event log.  
Deletion of user %1.  
Importing of user %1.  
Creation of user %1.  
Changing password for user %1.  
Modification of user %1 properties.  
Modification of user %1 notification properties for the  
following devices: %2.  
406  
8C0A0196  
2
Transfer of user %1 notification settings to user %2.  
6
Storage Management Appliance Software Event Code Definitions Application Notes  
 
Storage Management Appliance Audit Codes  
Table 3: Storage Management Appliance Audit Codes (Continued)  
Event ID Event Code Severity  
Description  
407  
8C0A0197  
2
Deletion of notification settings from user %1 and transferred  
to user %2.  
500  
501  
8C0A01F4  
8C0A01F5  
2
2
Starting backup to network share %1.  
Completion of backup operation that was started to network  
share %1. See %2 file on Management Appliance %3 for  
details.  
502  
8C0A01F6  
2
Cancellation of backup operation that was started to network  
share %1. See %2 file on Management Appliance %3 for  
details.  
600  
601  
8C0A0258  
8C0A0259  
2
2
Starting restore operation from network share %1.  
Completion of restore operation that was started to network  
share %1. See %2 file on Management Appliance %3 for  
details.  
602  
8C0A025A  
2
Cancellation of restore operation that was started from  
network share %1. See %2 file on Management Appliance  
%3 for details.  
603  
604  
900  
901  
904  
905  
906  
8C0A025B  
8C0A025C  
8C0A0384  
8C0A0385  
8C0A0388  
8C0A0389  
8C0A038A  
2
2
2
2
2
2
2
Clearing of backup log %1.  
Clearing of restore log %1.  
Starting %1.  
Stopping %1.  
Changing date/time to %1.  
Changing time zone to %1.  
Modification of SNTP time server - Enabled: %1, Server:%2,  
Frequency:%3.  
950  
951  
952  
953  
954  
960  
961  
962  
963  
964  
965  
970  
971  
972  
980  
981  
982  
1000  
1001  
8C0A03B6  
8C0A03B7  
8C0A03B8  
8C0A03B9  
8C0A03BA  
8C0A03C0  
8C0A03C1  
8C0A03C2  
8C0A03C3  
8C0A03C4  
8C0A03C5  
8C0A03CA  
8C0A03CB  
8C0A03CC  
8C0A03D4  
8C0A03D5  
8C0A03D6  
8C0A03E8  
8C0A03E9  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Launching of HSV element manager.  
Launching of HSG Element Manager.  
Launching of VersaStor.  
Launching of Automation.  
Launching of Management Agents.  
Launching of Network View.  
Launching of Secure Path Manager.  
Launching of Data Replication Manager.  
Launching of Enterprise Volume Manager.  
Launching of Storage Allocation Reporter.  
Launching of Storage Provisioner.  
Modification of IP address configuration.  
Modification of DNS server configuration.  
Modification of WINS server configuration.  
Modification of Administration Web Site properties.  
Modification of Global Network settings.  
Modification of Telnet Administration configuration.  
Changing Management Appliance name to %1.  
Changing Management Appliance membership to  
workgroup %1.  
Storage Management Appliance Software Event Code Definitions Application Notes  
7
Storage Management Appliance Audit Codes  
Table 3: Storage Management Appliance Audit Codes (Continued)  
Event ID Event Code Severity  
Description  
1002  
8C0A03EA  
2
Changing Management Appliance membership to domain  
%1.  
1003  
1004  
1005  
1006  
1010  
8C0A03EB  
8C0A03EC  
8C0A03ED  
8C0A03EE  
8C0A03F2  
2
2
2
2
2
Shutdown of Management Appliance.  
Changing domain/workgroup membership.  
Restarting Management Appliance.  
Scheduling Management Appliance for %1.  
Configuration of Management Appliance as the first domain  
controller in the new forest, %1. The new domain name is  
%2.  
1011  
1012  
8C0A03F3  
8C0A03F4  
2
2
Configuration of Management Appliance as the first domain  
controller in a new domain tree. The name of the new  
domain is %1 and has trust link with %2.  
Configuration of Management Appliance as the first domain  
controller in a new domain. The name of the new domain is  
%1 and is created in %2 domain.  
1013  
1020  
8C0A03F5  
8C0A03FC  
2
2
Configuration of Management Appliance as an additional  
domain controller for the domain %1.  
Modification of notification properties for event code %1 on  
%2.  
1021  
1022  
1030  
1031  
1032  
1033  
1040  
1041  
1042  
1050  
1055  
1056  
8C0A03FD  
8C0A03FE  
8C0A0406  
8C0A0407  
8C0A0408  
8C0A0409  
8C0A0410  
8C0A0411  
8C0A0412  
8C0A041A  
8C0A041F  
8C0A0420  
2
2
2
2
2
2
2
2
2
2
2
2
Configuration of notification for the following devices: %1.  
Clearing of notification settings for the following devices: %1.  
Download of audit log.  
Clearing of audit log.  
Modification of audit log properties.  
Acknowledgement of audits in the audit log.  
Adding of trap recipient %1.  
Removal of trap recipient %1.  
Modification of trap recipient %1.  
Setting SMTP server to %1 with IP address: %2.  
Logging in of user.  
Logging out of user.  
8
Storage Management Appliance Software Event Code Definitions Application Notes  
NetApp Filers Event Codes  
NetApp Filers Event Codes  
The following events are generated by NetApp Filer devices and are recorded in the Storage  
Management Appliance Event Log. A number of these events are associated with user-defined  
traps and most indicate a condition that is likely to have a negative impact on operations. A  
small number of events mark a return to normal operation after some period of abnormal  
operation.  
The Storage Management Appliance supports the NetApp MIB version 1.2.  
Table 4: NetApp Filer Event Codes  
Event  
Event ID  
Code  
880E0064  
880E0065  
Severity  
Description  
An unknown trap event was received.  
100  
2
3
101  
A polling-style trap built by the user using the SNMP traps  
command on the filer.  
102  
103  
104  
880E0066  
880E0067  
880E0068  
5
4
7
Disk Health Monitor reported a Disk Degraded-I/O Event.  
Disk Health Monitor reported a Disk Predictive-Failure Event.  
A user-defined trap indicating an extremely urgent situation,  
usually indicating that the system has failed and is shutting  
down.  
105  
106  
107  
108  
109  
880E0069  
880E006A  
880E006B  
880E006C  
880E006D  
5
6
5
4
2
A user-defined trap indicating a condition that should be  
corrected immediately, such as a failed disk.  
A user-defined trap indicating a critical condition, such as a  
hard device error.  
A user-defined trap indicating an error condition, such as a  
mistake in a configuration file.  
A user-defined trap indicating a condition which is not an error,  
but which may require special handling.  
A user-defined trap meant to provide information, such as an  
hourly uptime message.  
110  
111  
880E006E  
880E006F  
1
7
A user-defined trap used for debugging purposes.  
System is shutting down because the system has been running  
in degraded mode for 24 hours.  
112  
113  
114  
880E0070  
880E0071  
880E0072  
5
2
7
One or more disks failed.  
The failed disks have been repaired.  
Critical chassis or cpu fans have failed and the system is  
shutting down.  
115  
116  
117  
118  
880E0073  
880E0074  
880E0075  
880E0076  
5
3
2
7
One or more chassis fans failed.  
One or more chassis or cpu fans are in warning state.  
All fans are repaired.  
Critical power supplies or power rails failed and the system is  
shutting down.  
119  
120  
121  
880E0077  
880E0078  
880E0079  
5
3
2
One or more redundant power supplies failed.  
One or more power supplies or power rails in warning state.  
Previously-failed power supplies or power rails have been  
repaired.  
122  
123  
880E007A  
880E007B  
4
2
CPU utilization exceeds 90 percent.  
CPU utilization has dropped back below 90 percent.  
Storage Management Appliance Software Event Code Definitions Application Notes  
9
 
NetApp Filers Event Codes  
Table 4: NetApp Filer Event Codes (Continued)  
Event  
Code  
880E007C  
880E007D  
880E007E  
Event ID  
124  
Severity  
Description  
The NVRAM battery is fully discharged.  
The charge in the NVRAM battery is low.  
5
4
5
125  
126  
A node in a Cluster FailOver configuration failed. Its partner  
will assume service for the failed node.  
127  
128  
129  
130  
131  
132  
880E007F  
880E0080  
880E0081  
880E0082  
880E0083  
880E0084  
5
2
5
4
2
7
The partner has taken over for a failed cluster node.  
A cluster node has resumed operation.  
At least one volume is more than 98 percent full.  
At least one volume is more than 95 percent full.  
All volumes are now under 95 percent full.  
System temperature is too high to continue operating. The  
system is shutting down.  
133  
134  
135  
880E0085  
880E0086  
880E0087  
4
2
5
System temperature is too high and in the warning level.  
System temperature has returned to an acceptable value.  
A disk storage shelf reported a fault, probably due to a  
problem with drive placement, fans, power, or temperature.  
136  
137  
880E0088  
880E0089  
2
7
A previously-reported shelf fault is now corrected.  
The appliance’s overall status changed to ‘nonRecoverable,  
indicating a problem so severe that the appliance is shutting  
down.  
138  
139  
880E008A  
880E008B  
6
4
The appliance’s overall status changed to ‘critical, indicating a  
problem that needs immediate attention.  
The appliance’s overall status changed to ‘nonCritical,  
indicating a problem that needs attention.  
140  
141  
142  
143  
144  
145  
146  
880E008C  
880E008D  
880E008E  
880E008F  
880E0090  
880E0091  
880e0092  
2
2
2
2
2
2
2
The appliance’s overall status returned to normal.  
Cold Start.  
Warm Start.  
Link Down: %1  
Link Up: %1  
Authorization failure.  
EGP Peer down: %1  
10  
Storage Management Appliance Software Event Code Definitions Application Notes  
HP StorageWorks and McData Switch Event Codes  
HP StorageWorks and McData Switch Event Codes  
The following events are generated by HP StorageWorks switches and McData switches and  
are recorded in the Storage Management Appliance Event Log. Many of these event types  
have several possible states and each state has an appropriate severity code.  
The Storage Management Appliance supports the following StorageWorks and McData MIB  
versions:  
V1.9 for the ED-5000 series  
V1.10 for the EF-6000 series  
V1.0 for the ES-1000 series  
Table 5: HP StorageWorks and McData Event Codes  
Event  
ID  
Event  
Code  
Possible States Severity  
Description  
100  
101  
880C0064  
880C0065  
N/A  
2
An unknown trap event was received.  
online  
offline  
testing  
faulty  
2
5
2
7
0
B_Port Index %2 changed state to %1.%n  
A es1000PortBportScn is generated whenever  
a B_Port changes its operational state.  
unknown  
102  
103  
880C0066  
880C0067  
online  
offline  
testing  
faulty  
2
5
2
7
0
H_Port Index %2 changed state to %1.%n  
A es1000PortHportScn is generated whenever  
a H_Port changes its operational state  
unknown  
active  
2
2
7
Component Code %2 has changed state to  
%1.%n  
A es1000CompScn is generated whenever a  
COMPONENT status changes its operational  
state.  
updatebusy  
failed  
unknown  
0
104  
105  
106  
107  
880C0068  
880C0069  
880C006A  
880C006B  
online  
offline  
testing  
faulty  
2
5
2
7
0
Port Index %2 changed state to %1.%n  
An ed5000PortScn(1) is generated whenever  
a Fc_Port changes its operational state.  
unknown  
active  
2
3
2
7
0
FRU Code %2 has changed state to %1.%n  
An ed5000FruScn(2) is generated whenever a  
FRU status changes its operational state.  
backup  
updatebusy  
failed  
unknown  
online  
offline  
testing  
faulty  
2
5
2
7
0
Port Index %2 changed state to %1.%n  
An ef6000PortScn(1) is generated whenever a  
Fc_Port changes its operational state.  
unknown  
active  
2
3
2
7
0
FRU Code %2 has changed state to %1.%n  
An ef6000FruScn(2) is generated whenever a  
FRU status changes its operational state.  
backup  
updatebusy  
failed  
unknown  
Storage Management Appliance Software Event Code Definitions Application Notes  
11  
 
HP StorageWorks and McData Switch Event Codes  
Table 5: HP StorageWorks and McData Event Codes (Continued)  
Event  
ID  
Event  
Code  
Possible States Severity  
Description  
108  
880C006C  
N/A  
2
Device WWN: %1 currently attached to Port  
%2 has either successfully connected or is  
currently being rejected due to a Port Binding  
violation.%n  
An ef6000PortBindingViolation(3) is  
generated whenever the switch detects that a  
port binding violation occurs.  
109  
880C006D  
N/A  
2
Threshold Alert.%n  
ef6000PortIndex: %1%n  
ef6000TAIndex: %2%n  
An ef6000ThresholdAlert(4) is generated  
whenever a threshold alert occurs.  
113  
115  
117  
119  
121  
123  
880C0071  
880C0073  
880C0075  
880C0077  
880C0079  
880C007B  
informational  
informational  
warning  
2
2
3
2
3
3
Cold Start.  
Warm Start.  
Link Down: %1.  
Link Up: %1.  
informational  
warning  
Authorization failure.  
EGP Peer down: %1.  
warning  
12  
Storage Management Appliance Software Event Code Definitions Application Notes  
HP StorageWorks SAN and Brocade Switch Event Codes  
HP StorageWorks SAN and Brocade Switch Event Codes  
The following events are generated by HP StorageWorks SAN switches and Brocade switches  
and are recorded in the Storage Management Appliance Event Log. Many of these event types  
have several possible states and each state has an appropriate severity code.  
The Storage Management Appliance supports the StorageWorks SAN and Brocade MIB  
version 4.0.  
Table 6: StorageWorks SAN and Brocade Switch Event Codes  
Event  
ID  
Event  
Code  
Possible States Severity  
Description  
105  
88020069  
unknown  
online  
offline  
testing  
faulty  
0
2
5
2
7
Port Index %2 changed state to %1%n  
SSN: %3%n  
GroupName: %3%n  
GroupType: %5%n  
Group MemPosition: %6%n  
A swFCPortScn(3) is generated whenever  
an FC_Port changes its operational state.  
For instance, the FC_Port goes from on-line  
to offline. The VarBind in the Trap Data Unit  
shall contain the corresponding instance of  
the FC_Port's operational status and index.  
101  
103  
88020065  
88020067  
ok  
faulty  
unknown  
2
5
0
Switch is faulty.  
Faulty reason: %1%n  
SSN: %2%n  
GroupName: %3%n  
GroupType: %4%n  
Group MemPosition: %5%n  
A swFault(1) is generated whenever the  
diagnostics detects a fault with the switch.  
unknown  
faulty  
below minimum  
normal  
above maximum  
absent  
0
5
7
2
5
2
%5 is currently in state %1%n  
SSN: %7%n  
GroupName: %3%n  
GroupType: %8%n  
Group MemPosition: %9%n  
A swSensorScn(2) is generated whenever  
an environment sensor changes its  
operational state. For instance, a fan stops  
working. The VarBind in the Trap Data Unit  
shall contain the corresponding instance of  
the sensor status, sensor index, sensor type,  
sensor value (reading) and sensor  
information. Note that the sensor  
information contains the type of sensor and  
its number in textual format.  
107  
8802006B  
critical  
5
5
3
2
2
Event %1: %2 (severity level %3) - %5%n  
SSN: %6%n  
error  
warning  
informational  
debug  
GroupName: %7%n  
GroupType: %8%n  
GroupMemPosition: %9%n  
This trap is generated when an event whose  
level at or below swEventTrapLevel occurs.  
Storage Management Appliance Software Event Code Definitions Application Notes  
13  
 
HP StorageWorks SAN and Brocade Switch Event Codes  
Table 6: StorageWorks SAN and Brocade Switch Event Codes (Continued)  
Event  
ID  
Event  
Code  
Possible States Severity  
Description  
109  
8802006D  
informational  
normal  
faulty  
2
2
7
Fabric Watch has generated an event.%n  
Threshold %3 in Class/Area %1 at index  
%2 has generated event %7 with %5 on  
%6.%n  
This event is %8%n  
SSN: %9%n  
GroupName: %10%n  
GroupType: %11%n  
GroupMemPosition: %12%n  
Trap sent by Fabric Watch to notify of an  
event.  
111  
8802006F  
informational  
2
A track change has generated a trap.  
%1%n.  
SSN: %2  
GroupName: %3  
GroupType: %4  
GroupMemPosition: %5%n  
Trap sent for tracking login/logout/config  
changes.  
100  
113  
115  
117  
119  
121  
123  
88020064  
88020071  
88020073  
88020075  
88020077  
88020079  
8802007B  
informational  
informational  
informational  
warning  
2
2
2
3
2
3
3
An unknown trap event was received.  
Cold Start.  
Warm Start.  
Link Down: %1.  
informational  
informational  
informational  
Link Up: %1.  
Authorization failure.  
EGP Peer down: %1.  
14  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSG Element Manager Event Codes  
HSG Element Manager Event Codes  
The HSG Element Manager is an application provided with the Storage Management  
Appliance and used to configure and monitor HSG80/60 storage elements. The HSG Element  
Manager generates events that help a user understand the status of both the manager  
application and the storage elements. The system records these events in the Storage  
Management Appliance Event Log.  
Table 7: HSG Element Manager Event Codes  
Event ID  
6001  
6002  
6003  
6004  
6005  
6006  
6007  
6008  
6009  
6010  
6011  
6012  
6013  
6014  
6015  
6016  
6017  
6018  
6019  
6020  
6021  
6022  
6023  
6024  
6025  
6026  
6027  
6028  
6029  
6030  
6031  
6032  
6033  
6034  
6035  
Event Code  
88011771  
88011772  
88011773  
88011774  
88011775  
88011776  
88011777  
88011778  
88011779  
8801177A  
8801177B  
8801177C  
8801177D  
8801177E  
8801177F  
88011780  
88011781  
88011782  
88011783  
88011784  
88011785  
88011786  
88011787  
88011788  
88011789  
8801178A  
8801178B  
8801178C  
8801178D  
8801178E  
8801178F  
88011790  
88011791  
88011792  
88011793  
Severity  
2
Description  
HSGSubsystem object created.  
2
2
5
2
5
2
2
3
2
5
7
3
4
3
2
3
5
2
5
5
4
4
4
4
4
4
7
7
7
7
7
7
7
7
Sense Data found.  
%1 state changed to online  
%1 state changed to offline  
%1 container state changed to good  
%1 container state changed to failed  
%1 container state changed to Reconstructing  
%1 container state changed to Initializing  
%1 container state changed to Reduced  
%1 state changed to good. %2  
%1 state changed to failed. %2  
No controllers found  
New controller %1 found  
Other controller %1 unreachable  
Other controller %1 reachable  
Controller %1 Cache Battery state changed to good  
Controller %1 Cache Battery state changed to low  
Controller %1 Cache Battery state changed to bad  
Controller %1 Cache state changed to good  
Controller %1 Cache state changed to bad  
Controller %1 Cache state changed to invalid  
Failed to refresh HSGSubsystem  
Failed to refresh Virtual Disks  
Failed to refresh Storage Sets  
Failed to refresh Devices  
Failed to refresh Host Connections  
Failed to rescan HSGSubsystem  
Striped Mirror set modification. Members do not match  
Too few mirrorset members for striped mirror set  
Mirrorset already a member  
STL Exception generated. %1  
Unknown system Exception generated. %1  
HSG Exception generated. %1  
Invalid Controller Pointer  
Invalid Container Pointer. %1  
Storage Management Appliance Software Event Code Definitions Application Notes  
15  
 
HSG Element Manager Event Codes  
Table 7: HSG Element Manager Event Codes (Continued)  
Event ID  
6036  
6037  
6038  
6039  
6040  
6041  
6042  
6043  
6044  
6045  
6046  
6047  
6048  
6049  
6050  
6051  
6052  
6053  
6054  
6055  
6056  
6057  
6058  
6059  
6060  
6061  
6062  
6063  
6064  
6065  
6066  
6067  
6068  
6069  
6070  
6071  
6072  
6073  
6074  
6075  
6076  
Event Code  
88011794  
88011795  
88011796  
88011797  
88011798  
88011799  
8801179A  
8801179B  
8801179C  
8801179D  
8801179E  
8801179F  
880117A0  
880117A1  
880117A2  
880117A3  
880117A4  
880117A5  
880117A6  
880117A7  
880117A8  
880117A9  
880117AA  
880117AB  
880117AC  
880117AD  
880117AE  
880117AF  
880117B0  
880117B1  
880117B2  
880117B3  
880117B4  
880117B5  
880117B6  
880117B7  
880117B8  
880117B9  
880117BA  
880117BB  
880117BC  
Severity  
3
Description  
Device not found. %1  
%1 not found  
3
3
3
4
2
2
2
2
3
2
3
7
4
4
4
4
4
4
4
4
4
2
2
2
2
2
2
2
4
4
4
2
4
7
4
4
4
6
2
6
Storage Set not found  
Host Connection not found  
Test Unit Ready failed  
Virtual Disk %1 deleted  
Virtual Disk %1 created  
Device %1 added  
Device %1 deleted  
Host Connection %1 went offline  
Host Connection %1 went online  
Invalid parameter was found in request. %1  
Invalid Storage Set type found. %1  
Attempt to create virtual disk failed. %1  
Attempt to modify virtual disk failed. %1  
Attempt to delete virtual disk failed. %1  
Attempt to modify device failed. %1  
Attempt to modify Controller failed. %1  
Attempt to modify Host Connection failed. %1  
Attempt to delete Host Connection failed. %1  
Attempt to rename Host Connection failed. %1  
Snapshot: %1 not created.  
Snapshot: %1 created.  
Virtual Disk modified. %1  
%1 modified  
Controller modified. %1  
Host Connection %1 modified  
Host connection %1 has been renamed to %2  
Host Connection %1 deleted  
Attempt to rescan storage failed. %1  
Attempt to Delete Storage Set failed. %1  
Attempt to Delete Device failed. %1  
Virtual disk: %1, %2 member removed.  
Attempt to remove a member from a Virtual Disk failed. %1  
Invalid Device Pointer. %1  
Attempt to remove Failed Set member failed. %1  
Attempt to add member to Spare Set failed. %1  
Attempt to remove member from Spare Set failed. %1  
EMU state now invalid. %1  
EMU state now valid. %1  
Power supply has gone bad. %1  
16  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSG Element Manager Event Codes  
Table 7: HSG Element Manager Event Codes (Continued)  
Event ID  
6077  
6078  
6079  
6080  
6081  
6082  
6083  
6084  
6085  
6086  
6087  
6088  
6089  
6090  
6091  
6092  
6093  
6094  
6095  
6096  
6097  
6098  
6099  
6100  
6101  
6102  
6103  
6104  
6105  
6106  
6107  
6108  
6109  
6110  
6111  
6112  
6113  
6114  
6115  
6116  
6117  
Event Code  
880117BD  
880117BE  
880117BF  
880117C0  
880117C1  
880117C2  
880117C3  
880117C4  
880117C5  
880117C6  
880117C7  
880117C8  
880117C9  
880117CA  
880117CB  
880117CC  
880117CD  
880117CE  
880117CF  
880117D0  
880117D1  
880117D2  
880117D3  
880117D4  
880117D5  
880117D6  
880117D7  
880117D8  
880117D9  
880117DA  
880117DB  
880117DC  
880117DD  
880117DE  
880117DF  
880117E0  
880117E1  
880117E2  
880117E3  
880117E4  
880117E5  
Severity  
2
Description  
Power supply is now good. %1  
6
2
6
2
6
2
2
6
7
2
6
2
2
2
6
2
6
2
6
2
3
2
6
2
4
2
4
2
4
2
3
3
4
4
2
2
4
2
2
4
Fan has gone bad. %1  
Fan is now good. %1  
High Temperature detected. %1  
Temperature is within optimal range. %1  
Airflow is bad. %1  
Airflow is now good. %1  
EMU is present  
EMU is no longer present  
Cabinet %1 went offline  
Cabinet %1 went online  
Master cabinet has no controller installed. %1  
Master cabinet has controller installed. %1  
Controller present but present in slave cabinet. %1  
Master cabinet has controller installed. %1  
UPS has gone bad. %1  
UPS is now good. %1  
Shelf is bad. %1  
Shelf is good. %1  
Voltage has gone bad. %1  
Voltage is now good. %1  
Other controller failed  
Other controller now good  
Communication with subsystem has gone down. %1  
Regained communication to subsystem  
Attempt to create Remote Copy Set failed. %1  
Remote copy set: %1 created.  
Attempt to Delete Remote Copy Set failed. %1  
RCS: %1 deleted.  
Attempt to modify Remote Copy Set failed. %1  
%1 RCS has been modified.  
No Modifications were made. %1  
Attempt to set failsafe on Remote Copy Set failed. %1  
Attempt to Delete Association failed. %1  
Attempt to create Association failed. %1  
Association: %1 created.  
Association: %1 not deleted.  
Attempt to modify Association failed. %1  
%1 Association has been modified.  
Name is in use  
%1 unable to add to spare set  
Storage Management Appliance Software Event Code Definitions Application Notes  
17  
HSG Element Manager Event Codes  
Table 7: HSG Element Manager Event Codes (Continued)  
Event ID  
6118  
6119  
6120  
6121  
6122  
6123  
6124  
6125  
6126  
6127  
6128  
6129  
6130  
6131  
6132  
6133  
6134  
6135  
6136  
6137  
6138  
6139  
6140  
6141  
6142  
6143  
6144  
6145  
6146  
6147  
6148  
6149  
6150  
6151  
6152  
6153  
6154  
6155  
6156  
6157  
6158  
Event Code  
880117E6  
880117E7  
880117E8  
880117E9  
880117EA  
880117EB  
880117EC  
880117ED  
880117EE  
880117EF  
880117F0  
880117F1  
880117F2  
880117F3  
880117F4  
880117F5  
880117F6  
880117F7  
880117F8  
880117F9  
880117FA  
880117FB  
880117FC  
880117FD  
880117FE  
880117FF  
88011800  
88011801  
88011802  
88011803  
88011804  
88011805  
88011806  
88011807  
88011808  
88011809  
8801180A  
8801180B  
8801180C  
8801180D  
8801180E  
Severity  
2
Description  
Item is already used  
2
2
2
4
2
2
4
2
4
7
4
3
2
2
2
4
4
2
6
4
2
2
2
4
2
2
4
2
2
2
2
2
2
2
2
2
2
2
2
2
Device %1 added to Spare Set  
Device %1 removed from Spare Set  
Device removed from Failed Set  
Attempt to expand Virtual Disk failed. %1  
Virtual Disk expanded  
%1 Virtual Disk not expandable  
Incomplete Concatset modify: %1  
Storage Set modified  
Attempt to modify Chunksize failed  
HSGSubsystem Assertion  
Codeload failed. %1  
Codeload Error. %1  
Top Controller is rebooting  
Bottom Controller is rebooting  
Both Controllers are rebooting  
Could not locate top controller  
Could not locate bottom controller  
Operating state is normal. %1  
Operating state is failed. %1  
Operating state is impaired. %1  
Top controller is done rebooting  
Bottom controller is done rebooting  
Both controllers are done rebooting  
Reboot of controller failed. %1  
SCSI command did not complete. %1  
EMU modified  
EMU modify failed  
Unit is an Association Log Device  
Unit is an RCS Initiator  
Unit has been expanded  
Unit has no preferred path  
Unit is transportable  
Unit is a Snapshot  
Unit writeback cache is disabled  
Unit storage container is partitioned  
Incompatible storage container type  
No peer to peer configuration  
Unit is in Failed state  
Unit has too few devices  
Unit not in correct state  
18  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSG Element Manager Event Codes  
Table 7: HSG Element Manager Event Codes (Continued)  
Event ID  
6159  
6160  
6161  
6162  
6163  
6164  
6165  
6166  
6167  
6168  
6169  
6170  
6171  
6172  
6173  
6174  
6175  
6176  
6177  
6178  
6179  
6180  
Event Code  
8801180F  
88011810  
88011811  
88011812  
88011813  
88011814  
88011815  
88011816  
88011817  
88011818  
88011819  
8801181A  
8801181B  
8801181C  
8801181D  
8801181E  
8801181F  
88011820  
88011821  
88011822  
88011823  
88011824  
Severity  
2
Description  
Unit is used by another configuration  
2
2
2
2
2
2
3
3
4
3
4
2
2
4
2
7
2
2
4
2
2
Unit is a Snapshot source  
Subsystem firmware does not support snapshots  
Subsystem does not have peer to peer support enabled  
HSGSubsystem Miscellaneous info  
Mirror cache is not enabled  
Controller cache size is too small  
HSGSubsystem Unknown Status  
Subsystem has the maximum number of snapshots  
Not enough available physical disks or unused stripes  
Reached maximum physical disk count  
Virtual Disk is a target  
Initialize container failed. %1  
Initialized container successfully. %1  
No available containers  
Reservation mutex check failed  
Container not found. %1  
%1 Used by name list  
Unable to disable the PPRCMode  
Add VD member failed. %1  
Virtual Disk: %1, added member %2 successfully  
Check VirtualDisk not in REDUCE state or Replacement  
policy not NONE or not available physical disks  
6181  
6182  
88011825  
88011826  
2
4
Rejected because of reservation. %1  
Need ACS firmware revision 8.7 for management  
lockdown  
6183  
6184  
6185  
6186  
6187  
6188  
6189  
6190  
6191  
7001  
7002  
7003  
7004  
7005  
7006  
88011827  
88011828  
88011829  
8801182A  
8801182B  
8801182C  
8801182D  
8801182E  
8801182F  
88011B59  
88011B5A  
88011B5B  
88011B5C  
88011B5D  
88011B5E  
2
2
2
2
2
2
2
2
2
6
4
4
4
4
4
Virtual disk %1 has been reserved by %2  
A virtual disk has been unreserved. %1  
Virtual disk reservation failure. %1  
Management lock down change. %1  
No available disks  
Maximum number of members  
Replacement policy must be NOPOLICY  
Raidset must be in reduced state  
Code patch %1-%2 is Succesfully loaded on %3 controller  
HSGSubsystem API has lost comm to Subsystem. %1  
HSGSubsystem API has returned controller error text. %1  
HSGSubsystem API has received Invalid show this output  
HSGAPI::getAllControllers: Invalid SHOW OTHER output  
Invalid SHOW UNIT output %1  
HSGSubsystem API has received Invalid show storage  
output. %1  
Storage Management Appliance Software Event Code Definitions Application Notes  
19  
HSG Element Manager Event Codes  
Table 7: HSG Element Manager Event Codes (Continued)  
Event ID  
7007  
Event Code  
88011B5F  
Severity  
4
Description  
Invalid SHOW DEV FULL output  
7008  
88011B60  
4
3
3
3
HSGSubsystem API has received Invalid show connection  
output. %1  
7009  
7010  
7011  
88011B61  
88011B62  
88011B63  
HSGSubsystem API received modification request but no  
changes were found. %1  
HSGSubsystem API received delete request but no changes  
were found. %1  
HSGSubsystem API invalid CLI syntax or incomplete CLI  
command error (Last Status). %1  
7012  
7013  
7014  
7015  
7016  
88011B64  
88011B65  
88011B66  
88011B67  
88011B68  
2
2
2
2
4
HSGSubsystem API has returned controller warning text  
HSGSubsystem API This controller rebooting  
HSGSubsystem API Other controller rebooting  
HSGSubsystem API Both controllers rebooting  
HSGAPI::getAllAssociations: Invalid SHOW AllAssociations  
output %1  
7017  
88011B69  
4
HSGSubsystem API has received Invalid show Remote Copy.  
%1  
7018  
7019  
7020  
7021  
7022  
8204  
88011B6A  
88011B6B  
88011B6C  
88011B6D  
88011B6E  
8801200C  
4
4
3
3
3
7
HSGSubsystem API Setting Host connection failure  
HSGAPI::getAutospare, Invalid SHOW FAILEDSET output  
Comm path switched. %1  
Unable to switch comm path. %1  
Last Status  
A spurious interrupt was detected during the execution of a  
Subsystem Built-In Self Test  
8205  
8206  
8801200D  
8801200E  
7
7
An unrecoverable error was detected during execution of  
the HOST PORT Subsystem Test. The system will not be able  
to communicate with the host.  
An unrecoverable error was detected during execution of  
the UART/DUART Subsystem Test. This will cause the  
console to be unusable. This will cause failover  
communications to fail.  
8207  
8301  
8302  
8801200F  
8801206D  
8801206E  
7
7
7
An unrecoverable error was detected during execution of  
the FX Subsystem Test.  
An unrecoverable error was detected during execution of  
the PCI9060ES Test.  
An unrecoverable error was detected during execution of  
the Device Port Subsystem Built-In Self Test. One or more of  
the device ports on the controller module has failed;  
some/all of the attached storage is no longer accessible via  
this controller.  
8303  
8304  
8305  
8306  
8307  
8308  
8309  
8801206F  
88012070  
88012071  
88012072  
88012073  
88012074  
88012075  
7
2
2
6
2
3
2
Deletion of component failed.  
A component location has been updated.  
A component name has been updated.  
HSG not communicating.  
HSG is communicating.  
Log approaching max size, prior entries removed.  
New HSG found.  
20  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
HSV Element Manager Event Codes  
The HSV Element Manager is an application provided with the Storage Management  
Appliance that is used to configure and monitor HSV110 Array Controllers. The HSV  
Element Manager generates controller events and management agent events that help users  
understand the status of both the manager application and the storage elements.  
The Storage Management Appliance supports the HSV MIB version 2.0.  
Controller Events  
Table 8 shows events generated by the HSV Controller, which are logged in the Storage  
Management Appliance Event Log. The Software Component ID (SWC ID) and Event  
Number (Evt. No.) codes can be used to correlate events recorded in the Controller Event Log  
of the HSV Element Manager with the events logged in the Storage Management Appliance  
Event Log.  
Table 8: HSV Element Manager Event Codes: Controller Events  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
100  
88030064  
3
0
0
Storage Cell: %1 Event Code: %2 Description: recognized Controller event  
generated.  
256  
88030100  
2
1
0
Storage Cell: %1 Event Code: %2 Description: During Executive Services  
initialization the system time value was set to the value contained in the time field.  
The action field contains one of the following codes which describes the condition  
that caused the time value to be: 0 = TOY clock unavailable; time reset to default  
date and time. 1 = TOY clock time value was less than or equal to the last known  
time value previously stored in nonvolatile memory; time reset to default date and  
time. 2 = EDC was bad for last known time value previously stored in nonvolatile  
memory; time reset to default date and time. 3 = TOY clock not running; time  
reset to default date and time. 4 = TOY clock time value believed to be accurate;  
time set to TOY clock time value.  
257  
88030101  
2
1
1
Storage Cell: %1 Event Code: %2 Description: The system time value was set to  
the value contained in the time field by a call to the EXEC$SET_TIME service. As  
part of setting the time in a dual HSV110 controller configuration, the times are  
synchronized. The action field contains one of the following codes which  
describes the action taken: 0 = The time was set to the time value on this HSV110  
controller. 1 = The master HSV110 controller requested the slave HSV110  
controller to set it’s time to the time value. 2 = The slave HSV110 controller set the  
local time to the time value. 3 = The HSV110 controller’s TOY clock was set to the  
time value.  
768  
769  
88030300  
88030301  
2
6
3
3
0
1
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
in the node_name field has failed in communicating with the Cabinet (Rack) Bus  
Interface Controller.  
Storage Cell: %1 Event Code: %2 Description: The physical disk drive identified  
by the device field has been rendered inoperable. If the flags.quorum_disk flag is  
nonzero, the physical disk drive is the Storage System Quorum disk identified in  
the quorum_sequence field. If the flags.inq_state flag is nonzero, the content of  
the inq_data and capacity fields is valid. If the rss_flags.member_abnormal flag  
is nonzero, the content of the member_state field is valid. The rack_num field will  
not be valid until a future release.  
770  
88030302  
3
3
2
Storage Cell: %1 Event Code: %2 Description: The physical disk drive identified  
in the node_name field will not be used because the maximum number of  
physical disk drives already exist in the current Storage System.  
Storage Management Appliance Software Event Code Definitions Application Notes  
21  
   
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
771  
88030303  
2
3
3
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller has  
begun booting.  
772  
88030304  
2
3
4
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller, identified  
in the node_name field, has finished the process of bringing the Storage System,  
identified in the cell_tag fields, online.  
773  
774  
88030305  
88030306  
2
2
3
3
5
6
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
in the node_name field has been joined into the Storage System.  
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
in the node_name field has been ousted from the Storage System, identified in  
the cell_tag fields  
775  
88030307  
88030308  
88030400  
2
2
6
3
3
4
7
8
0
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
in the node_name field is now the Storage System master, identified in the  
cell_tag fields, master  
776  
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
in the node_name field has been brought into the Storage System, identified in  
the cell_tag fields.  
1024  
Storage Cell: %1 Event Code: %2 Description: HSV110 controller operation was  
terminated due to an unrecoverable event detected by either software or  
hardware or due to an action initiated via the Storage System Management  
Interface.  
1025  
1026  
88030401  
88030402  
6
6
4
4
1
2
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
in the lter.terminating_ctrlr field sent a last gasp message prior to terminating  
operation.  
Storage Cell: %1 Event Code: %2 Description: A machine check occurred while  
a termination event was being processed. The post-termination operation being  
performed at the time the event occurred can be derived from the  
lter.reuea_index field.  
Note: The lteihd and lter fields may not describe the event that caused the  
HSV110 controller to terminate operation depending on how far termination  
processing got before the machine check occurred.  
22  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
1027  
88030403  
6
4
3
Storage Cell: %1 Event Code: %2 Description: An unexpected event occurred  
while a termination event was being processed. The value contained in the  
uei.type field describes the event as follows: 0 = Unrecognized Unexpected Event  
code. 1 = Power failure before initialization could complete. 2 = Recursive  
termination before initialization could complete. 3 = Terminated during the first  
part post-termination preparation. 4 = Terminated during the load of the G3  
Glue registers. 5 = Terminated during the second part post-termination  
preparation. 6 = Terminated during event report block load. 7 = Terminated  
during initialization of all hardware components and software data structures in  
preparation for restart. 8 = Terminated during execution of an unrecognized  
post-termination operation (premature). 9 = Power failure during execution of a  
post-termination operation. A = No good entries found in Termination Event  
Array. B = The EDC of one or more Termination Event Array entries is bad. C =  
Terminatio n Event Array entry control block revision is different. D = Termination  
Event Array entry information block revision is different. E = Termination Event  
Array entry up time value is greater than the system’s up time value. F =  
Termination Event Array entry up time value is less than the previous entry’s up  
time value. 10= Termination Event Array entry sequence number value is less  
than the previous entry’s sequence number value. 11= Detected an unrecognized  
dump/restart control code. 12= Failed to terminate the entity dump loop. 13=  
Unexpected dump entity size. 14= Unexpected Event Log Packet processing stage  
code. 15= Number of Termination Parameters supplied not equal to maximum  
allowed as required. The post-termination operation being performed at the time  
the unexpected event occurred is contained in the uei.pto field.  
Note: The lteihd and lter fields may not describe the event that caused the  
HSV110 controller to terminate operation depending on how far t ermination  
processing got before the unexpected event occurred.  
1028  
88030404  
2
4
4
Storage Cell: %1 Event Code: %2 Description: The Storage System Event Log  
validation completed successfully. The content of the cinfo.scelcbi.status field, the  
cinfo.scelcbi structure, and the minfo.scelmi structure show the validated state of  
the Storage System Event Log. The meaning of the status value contained in the  
cinfo.scelcbi.status field is as follows: 0 = No problems found.  
Note: The content of the ainfo fields, cinfo.sctelcbi structure, and minfo.sctelmi  
structure is undefined.  
Storage Management Appliance Software Event Code Definitions Application Notes  
23  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
1029  
88030405  
2
4
5
Storage Cell: %1 Event Code: %2 Description: The Storage System Event Log  
validation failed. The content of the cinfo.scelcbi.status field, the cinfo.scelcbi  
structure, and the minfo.scelmi structure show the state of the Storage System  
Event Log at the time of the failure. The content and state of the Storage System  
Event Log have been initialized to their initial operational settings. The meaning  
of the status value contained in the cinfo.scelcbi.status field is as follows: 1 =  
Cookie value is not as expected. 2 = Event data overflows the buffer. 3 = Event  
data size is not a multiple of 4 bytes, is less than the minimum, or is greater than  
the maximum. 4 = Event Information Packet type is greater than the maximum. 5  
= Event information size is not a multiple of 4 bytes, is less than the minimum, is  
greater than the maximum, doesn’t match the Event Information Packet type size,  
or when combined with the entry header size doesn’t equal the entry size. 6 =  
Event code is zero. 7 = Event is out of sequence. 8 = Dead space area at the end  
of a partially packed buffer contains a nonzero value. 9 = An event data block  
containing a nonzero value was found after end of event data was detected. A =  
Sequence number reset flag not set as expected. B = The event log contains no  
entries. C = Event data block read failed during maintenance verification. D =  
Event data block read failed during maintenance completion. E = Event data  
block erase failed during maintenance completion. F = Control block read failed  
during maintenance verification.  
Note: The content of the ainfo fields, cinfo.sctelcbi structure, and minfo.sctelmi  
structure is undefined.  
1030  
1031  
1032  
88030406  
88030407  
88030408  
6
6
2
4
4
4
6
7
8
Storage Cell: %1 Event Code: %2 Description: Event reports were lost due to an  
insufficient supply of Event Log Packets on the HSV110 controller that is the  
Storage System Master. The ainfo.events_not_reported field shows the number of  
event reports lost.  
Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field  
cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.  
Storage Cell: %1 Event Code: %2 Description: Event reports were lost due to an  
insufficient supply of Event Log Packets on the HSV110 controller that is not the  
Storage System Master. The ainfo.events_not_reported field shows the number of  
event reports lost.  
Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field  
cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.  
Storage Cell: %1 Event Code: %2 Description: The Storage System Termination  
Event Log has become inaccessible. The content of the cinfo.sctelcbi.status field,  
the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the current state  
of the Storage System Termination Event Log. The meaning of the status value  
contained in the cinfo.sctelcbi.status field is as follows: F = Control block read  
failed during maintenance verification. 10= Control block read failed during  
maintenance verification. 11= Event data block write failed during maintenance  
update. 12= Control block write failed during maintenance completion. 13=  
Storage System Termination Event Log related send was unsuccessful or the  
master found that the Storage System Termination Event Log is inaccessible. 16=  
Event data block read failed during retrieval request.  
Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi  
structure is undefined.  
24  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
1033  
88030409  
2
4
9
Storage Cell: %1 Event Code: %2 Description: The Storage System Termination  
Event Log validation completed successfully. The content of the  
cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi  
structure show the validated state of the Storage System Termination Event Log.  
The meaning of the status value contained in the cinfo.sctelcbi.status field is as  
follows: 0 = No problems found.  
Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi  
structure is undefined.  
1034  
8803040a  
2
4
a
Storage Cell: %1 Event Code: %2 Description: The Storage System Termination  
Event Log validation failed. The content of the cinfo.sctelcbi.status field, the  
cinfo.sctelcbi structure, and the minfo.sctelmi structure show the state of the  
Storage System Termination Event Log at the time of the failure. The meaning of  
the status value contained in the cinfo.sctelcbi.status field is as follows: F =  
Control block read failed during maintenance verification. 10= Control block  
read failed during maintenance verification. 11= Event data block write failed  
during maintenance update. 12= Control block write failed during maintenance  
completion. 13= Storage System Termination Event Log related send was  
unsuccessful or the master found that the Storage System Termination Event Log is  
inaccessible. 16= Event data block read failed during retrieval request.  
Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi  
structure is undefined.  
1035  
8803040b  
2
4
b
Storage Cell: %1 Event Code: %2 Description: The Storage System Termination  
Event Log has been updated with the termination event information obtained  
from the HSV110 controller that is not the Storage System Master. The content of  
the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi  
structure show the updated state of the Storage System Termination Event Log.  
The meaning of the status value contained in the cinfo.sctelcbi.status field is as  
follows: 0 = No problems found.  
Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi  
structure is undefined.  
1036  
1037  
8803040c  
8803040d  
6
2
4
4
c
Storage Cell: %1 Event Code: %2 Description: The Fault Manager on the  
Storage System Master received an invalid Event Information Packet from the  
remote Fault Manager. The header information from the invalid Event Information  
packet is contained in the ainfo.remote_event field.  
Note: The content of the ainfo.quiesce_type field, ainfo.events_not_reported field,  
cinfo.scelcbi structure, cinfo.sctelcbi structure, minfo.scelmi structure, and  
minfo.sctelmi structure is undefined.  
d
Storage Cell: %1 Event Code: %2 Description: The Fault Manager operation  
was made quiescent. If the ainfo.quiesce_type field is equal to 0, the operation  
was performed on both HSV110 controllers. If the ainfo.quiesce_type field is  
equal to 1, the operation was performed only on the HSV110 controller that is  
not the Storage System Master.  
Note: The content of the ainfo.events_not_reported field, cinfo.scelcbi structure,  
cinfo.sctelcbi structure, minfo.scelmi structure, and minfo.sctelmi structure is  
undefined.  
1038  
8803040e  
6
4
e
Storage Cell: %1 Event Code: %2 Description: An HSV110 controller sent a last  
gasp message prior to terminating operation with an indication that the HSV110  
controller identified in the lter.terminating_ctrlr field should also terminate  
operation.  
Storage Management Appliance Software Event Code Definitions Application Notes  
25  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
1536  
88030600  
6
6
0
Storage Cell: %1 Event Code: %2 Description: A physical disk drive has  
reported that it has exceeded its failure prediction threshold. The identity of the  
physical disk drive is contained in the device field. The Fibre Channel port used  
to communicate with the physical disk drive is contained in the cerp_id field. The  
HSV110 controller internal Fibre Channel port number used to communicate with  
the physical disk drive is contained in the port field. The arbitrated loop physical  
address of the physical disk drive is contained in the al_pa field. If the bay field  
contains a value other than zero, the location of the physical disk drive is  
contained in the rack_num, dencl_num, and bay fields. If the bay field contains  
a zero, the location of the physical disk drive is unknown and the content of the  
rack_num and dencl_num fields is undefined. The rack_num field will not be  
valid until a future release. The Fibre Channel Exchange Descriptor class is  
contained in the fed_class field. The command issued to the physical disk drive is  
contained in t he cmd field. The sense data obtained from the physical disk drive  
as a result of the failure prediction threshold exceeded error is contained in the  
error field.  
1537  
88030601  
3
6
1
Storage Cell: %1 Event Code: %2 Description: A Fibre Channel port on the  
HSV110 controller has failed to respond. The identity of the affected Fibre  
Channel port is contained in the cerp_id field. The HSV110 controller internal  
Fibre Channel port number of the affected Fibre Channel port is contained in the  
port field. The peb array contains the port event block information. The  
peq_frz_prod_index field contains the index to the port event block in use when  
the Tachyon chip entered the frozen state. The peq_prod_index field contains the  
index to the next port event block. The peq_cons_index field contains the index  
to the next port event block to be acted upon. The failure_cause field contains the  
internal routing.  
1538  
88030602  
2
6
2
Storage Cell: %1 Event Code: %2 Description: A physical disk drive has  
reported a check condition error. The identity of the physical disk drive is  
contained in the device field. The Fibre Channel port used to communicate with  
the physical disk drive is contained in the cerp_id field. The HSV110 controller  
internal Fibre Channel port number used to communicate with the physical disk  
drive is contained in the port field. The arbitrated loop physical address of the  
physical disk drive is contained in the al_pa field. If the bay field contains a  
value other than zero, the location of the physical disk drive is contained in the  
rack_num, dencl_num, and bay fields. If the bay field contains a zero, the  
location of the physical disk drive is unknown and the content of the rack_num  
and dencl_num fields is undefined. The rack_num field will not be valid until a  
future release. The Fibre Channel Exchange Descriptor class is contained in the  
fed_class field. The command issued to the physical disk drive is contained in the  
cmd field. The sense data obt ained from the physical disk drive as a result of the  
check condition error is contained in the error field.  
26  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
1539  
1540  
1541  
88030603  
88030604  
88030605  
3
6
3
4
5
Storage Cell: %1 Event Code: %2 Description: A frame sent to a physical disk  
drive or another HSV110 controller via the mirror port or a Drive Enclosure  
Environmental Monitoring Unit has timed out. The identity of the intended  
recipient is contained in the device field. The Fibre Channel port over which the  
frame was sent is identified in the cerp_id field. The HSV110 controller internal  
Fibre Channel port number over which the frame was sent is contained in the  
port field. The arbitrated loop physical address of the intended recipient is  
contained in the al_pa field. If the bay field contains a value other than zero, the  
intended recipient was the physical disk drive located as indicated by the content  
of the rack_num, dencl_num, and bay fields. If the bay field contains a zero, the  
location of the intended recipient is unknown and the content of the rack_num  
and dencl_num fields is undefined. The rack_num field will not be valid until a  
future release. The number of timeouts detected is contained in the num_times  
field.  
3
6
Storage Cell: %1 Event Code: %2 Description: Work was unexpectedly sent to  
this HSV110 controller by a physical disk drive or another HSV110 controller.  
This HSV110 controller did not originate the work. The identity of the sender is  
contained in the device field. The Fibre Channel port over which the unexpected  
work was received is identified in the cerp_id field. The HSV110 controller  
internal Fibre Channel port number over which the unexpected work was  
received is contained in the port field. The arbitrated loop physical address of  
the sender is contained in the al_pa field. If the bay field contains a value other  
than zero, the sender was the physical disk drive located as indicated by the  
content of the rack_num, dencl_num, and bay fields. If the bay field contains a  
zero, the location of the sender is unknown and the content of the rack_num and  
dencl_num fields is undefined. The rack_num field will not be valid until a future  
release. The hdr_cdb field contains the command descriptor block and Fibre  
Channel header information associated with the unexpected work.  
3
6
Storage Cell: %1 Event Code: %2 Description: Work has been sent to a physical  
disk drive or another HSV110 controller via the mirror port but it did not  
respond. The identity of the intended target is contained in the device field. The  
Fibre Channel port over which the work was sent is identified in the cerp_id field.  
The HSV110 controller internal Fibre Channel port over which the work was sent  
is contained in the port field. The arbitrated loop physical address of the  
intended target is contained in the al_pa field. If the bay field contains a value  
other than zero, the intended target was the physical disk drive located as  
indicated by the content of the rack_num, dencl_num, and bay fields. If the bay  
field contains a zero, the location of the intended target is unknown and the  
content of the rack_num and dencl_num fields is undefined. The rack_num field  
will not be valid until a future release. The Fibre Channel Exchange Descriptor  
class is contained in the fed_class field. The command issued to the intended  
target is contained in the c md field. Note that in this case the content of the  
error field is undefined.  
Storage Management Appliance Software Event Code Definitions Application Notes  
27  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
1543  
88030607  
3
6
7
Storage Cell: %1 Event Code: %2 Description: A Target Discovery Service  
Descriptor frame sent to a physical disk drive has timed out. The identity of the  
physical disk drive is contained in the device field. The Fibre Channel port used  
to communicate with the physical disk drive is contained in the cerp_id field. The  
HSV110 controller internal Fibre Channel port number used to communicate with  
the physical disk drive is contained in the port field. The arbitrated loop physical  
address of the physical disk drive is contained in the al_pa field. If the bay field  
contains a value other than zero, the location of the physical disk drive is  
contained in the rack_num, dencl_num, and bay fields. If the bay field contains  
a zero, the location of the physical disk drive is unknown and the content of the  
rack_num and dencl_num fields is undefined. The rack_num field will not be  
valid until a future release. The Fibre Channel Exchange Descriptor class is  
contained in the fed_class field. The command issued to the physical disk drive is  
contained in th e cmd field. Note that in this case the content of the error field is  
undefined.  
1544  
88030608  
2
6
8
Storage Cell: %1 Event Code: %2 Description: An excessive number of link  
errors were detected on a HSV110 controller’s Fibre Channel port. The identity  
of the affected Fibre Channel port is contained in the cerp_id field. The HSV110  
controller internal Fibre Channel port number of the affected Fibre Channel port  
is contained in the port field. This is an informational event triggered by the  
occurrence of an excessive number of Tachyon chip link status errors detected  
within a particular link status error type. The number of occurrences of each link  
status error type is contained in a separate type-specific field (e.g.,  
loss_of_signal, bad_rx_char, etc.). The HSV110 controller checks each of its  
Fibre Channel port’s for excessive link status errors periodicaly.  
1545  
88030609  
6
6
9
Storage Cell: %1 Event Code: %2 Description: A physical disk drive has  
reported numerous failure prediction threshold exceeded errors. The identity of  
the physical disk drive is contained in the device field. The Fibre Channel port  
used to communicate with the physical disk drive is contained in the cerp_id field.  
The HSV110 controller internal Fibre Channel port number used to communicate  
with the physical disk drive is contained in the port field. The arbitrated loop  
physical address of the physical disk drive is contained in the al_pa field. If the  
bay field contains a value other than zero, the location of the physical disk drive  
is contained in the rack_num, dencl_num, and bay fields. If the bay field contains  
a zero, the location of the physical disk drive is unknown and the content of the  
rack_num and dencl_num fields is undefined. The rack_num field will not be  
valid until a future release. The Fibre Channel Exchange Descriptor class is  
contained in the fed_class field. The num_times field is the number of failure  
prediction threshol d exceeded errors reported by the physical disk drive in the  
previous minute.  
28  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
1546  
8803060a  
2
6
a
Storage Cell: %1 Event Code: %2 Description: A physical disk drive has  
reported numerous check condition errors. The identity of the physical disk drive  
is contained in the device field. The Fibre Channel port used to communicate  
with the physical disk drive is contained in the cerp_id field. The HSV110  
controller internal Fibre Channel port number used to communicate with the  
physical disk drive is contained in the port field. The arbitrated loop physical  
address of the physical disk drive is contained in the al_pa field. If the bay field  
contains a value other than zero, the location of the physical disk drive is  
contained in the rack_num, dencl_num, and bay fields. If the bay field contains  
a zero, the location of the physical disk drive is unknown and the content of the  
rack_num and dencl_num fields is undefined. The rack_num field will not be  
valid until a future release. The Fibre Channel Exchange Descriptor class is  
contained in the fed_class field. The num_times field is the number of check  
condition errors reported by the physical disk drive in the previous minute.  
1547  
8803060b  
3
6
b
Storage Cell: %1 Event Code: %2 Description: A non-data exchange frame sent  
to a physical disk drive has timed out. The identity of the physical disk drive is  
contained in the device field. The Fibre Channel port used to communicate with  
the physical disk drive is contained in the cerp_id field. The HSV110 controller  
internal Fibre Channel port number used to communicate with the physical disk  
drive is contained in the port field. The arbitrated loop physical address of the  
physical disk drive is contained in the al_pa field. If the bay field contains a  
value other than zero, the location of the physical disk drive is contained in the  
rack_num, dencl_num, and bay fields. If the bay field contains a zero, the  
location of the physical disk drive is unknown and the content of the rack_num  
and dencl_num fields is undefined. The rack_num field will not be valid until a  
future release. The Fibre Channel Exchange Descriptor class is contained in the  
fed_class field. The command issued to the physical disk drive is contained in the  
cmd field. Note that in this case the content of the error field is undefined.  
1548  
1549  
8803060c  
8803060d  
2
2
6
6
c
Storage Cell: %1 Event Code: %2 Description: A loop switch has been detected  
on a Fibre Channel port. The identity of the Fibre Channel port is contained in  
the cerp_id field. The HSV110 controller internal Fibre Channel port number is  
contained in the port field. Note that in this case the device, al_pa, rack_num,  
dencl_num, bay, fed_class and num_times fields are undefined.  
d
Storage Cell: %1 Event Code: %2 Description: The location of a physical disk  
drive previously reported as unknown is now known. The identity of the physical  
disk drive is contained in the device field. The Fibre Channel port used to  
communicate with the physical disk drive is contained in the cerp_id field. The  
HSV110 controller internal Fibre Channel port number used to communicate with  
the physical disk drive is contained in the port field. The arbitrated loop physical  
address of the physical disk drive is contained in the al_pa field. The location of  
the physical disk drive is contained in the rack_num, dencl_num, and bay fields.  
The rack_num field will not be valid until a future release. Note that in this case  
the content of the fed_class and num_times fields is undefined.  
Storage Management Appliance Software Event Code Definitions Application Notes  
29  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
1550  
8803060e  
6
6
e
Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental  
Monitoring Unit requested a code update but the code update could not be  
found, so the update was not performed. The identity of the affected Drive  
Enclosure Environmental Monitoring Unit is contained in the device field. The  
Fibre Channel port used to communicate with the Drive Enclosure Environmental  
Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal  
Fibre Channel port number used to communicate with the Drive Enclosure  
Environmental Monitoring Unit is contained in the port field. The location of the  
Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and  
dencl_num fields. The rack_num field will not be valid until a future release.  
Note that in this case the content of the al_pa, bay, fed_class and num_times  
field is undefined.  
1551  
8803060f  
6
6
f
Storage Cell: %1 Event Code: %2 Description: The Drive Enclosure  
Environmental Monitoring Unit is able to communicate with a physical disk drive  
but this HSV110 controller is unable to communicate with that physical disk drive  
on the Fibre Channel bus. The identity of the Drive Enclosure Environmental  
Monitoring Unit is contained in the device field. The Fibre Channel port used to  
communicate with the physical disk drive is contained in the cerp_id field. The  
HSV110 controller internal Fibre Channel port number used to communicate with  
the physical disk drive is contained in the port field. The location of the physical  
disk drive is contained in the rack_num, dencl_num, and bay fields. The  
rack_num field will not be valid until a future release. Note that in this case the  
content of the al_pa, fed_class and num_times fields is undefined.  
1552  
88030610  
6
6
10  
Storage Cell: %1 Event Code: %2 Description: The Drive Enclosure  
Environmental Monitoring Unit is unable to communicate with this HSV110  
controller. The Drive Enclosure Environmental Monitoring Unit has either stopped  
communicating with the HSV110 controller, or is not connected to the rack. If the  
Drive Enclosure Environmental Monitoring Unit is not connected to the rack, then  
the location of the Drive Enclosure Environmental Monitoring Unit is unknown. If  
the bay field contains a value other than zero, the identity of the Drive Enclosure  
Environmental Monitoring Unit is contained in the device field. If the bay field  
contains a zero, the content of the device field is undefined. The Fibre Channel  
port used to communicate with the Drive Enclosure Environmental Monitoring  
Unit is contained in the cerp_id field. The HSV110 controller internal Fibre  
Channel port number used to communicate with the Drive Enclosure  
Environmental Monitoring Unit is contained in the port field. If the bay field  
contains a value other than zero, the location of the Dr ive Enclosure  
Environmental Monitoring Unit is contained in the rack_num and dencl_num  
fields. If the bay field contains a zero, the location of the Drive Enclosure  
Environmental Monitoring Unit is unknown and the content of the rack_num and  
dencl_num fields is undefined. The rack_num field will not be valid until a future  
release. Note that in this case the content of the al_pa, fed_class and num_times  
fields is undefined.  
30  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
1554  
88030612  
2
6
12  
Storage Cell: %1 Event Code: %2 Description: The retry count for a task  
assigned to a Drive Enclosure Environmental Monitoring Unit has been  
exhausted. The Fibre Channel port used to communicate with the physical disk  
drive is contained in the cerp_id field. The HSV110 controller internal Fibre  
Channel port number used to communicate with the physical disk drive is  
contained in the port field. The peb array contains the task list that was intended  
to be sent to the Drive Enclosure Environmental Monitoring Unit. The  
peq_frz_prod_index field contains the task that was being retried. The  
peq_prod_index field contains the drive enclosure where the physical disk drive  
used to communicate with the Drive Enclosure Environmental Monitoring Unit is  
located. The peq_cons_index field identifies the Fibre Channel loop pair (0 =  
Loop A, 1 = Loop B) used to communicate with the physical disk drive that was  
used to communicate with the Drive Enclosure Environmental Monitoring Unit.  
The failure_cause field contains the bay where the physical disk drive used to  
communicate with the  
1555  
88030613  
2
6
13  
Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental  
Monitoring Unit is able to communicate with this HSV110 controller. The identity  
of the Drive Enclosure Environmental Monitoring Unit is contained in the device  
field. The Fibre Channel port used to communicate with the Drive Enclosure  
Environmental Monitoring Unit is contained in the cerp_id field. The HSV110  
controller internal Fibre Channel port number used to communicate with the  
Drive Enclosure Environmental Monitoring Unit is contained in the port field. The  
location of the Drive Enclosure Environmental Monitoring Unit is contained in the  
rack_num and dencl_num fields. The rack_num field will not be valid until a  
future release. Note that in this case the content of the bay, fed_class and  
num_times fields is undefined.  
1556  
1557  
1558  
1559  
88030614  
88030615  
88030616  
88030617  
6
6
6
6
6
6
6
6
14  
15  
16  
17  
Storage Cell: %1 Event Code: %2 Description: There are too many drive  
enclosures. The Fibre Channel port with too many drive enclosures attached to  
the HSV110 controller is contained in the cerp_id field. Note that in this case the  
content of the bay, fed_class, rack_num, dencl_num and num_times fields is  
undefined.  
Storage Cell: %1 Event Code: %2 Description: The cable connected to the I/O  
module is attached to the wrong Fibre Channel port. The Fibre Channel port  
incorrectly attached to the HSV110 controller is contained in the cerp_id field.  
Note that in this case the content of the bay, fed_class, rack_num, dencl_num  
and num_times fields is undefined.  
Storage Cell: %1 Event Code: %2 Description: A HSV110 controller does not  
have an address on the enclosure address bus. The HSV110 controller location  
cannot be identified. Note that in this case the content of the bay, fed_class,  
rack_num, dencl_num, alpa, device, cerp_id, port, and num_times fields are  
undefined.  
Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental  
Monitoring Unit has detected a physical disk drive that was preventing proper  
loop operation. The physical disk drive has been bypassed and is ready for  
replacement. The location of this physical disk drive is specified by the  
rack_num, bay, and dencl_num fields. The rack_num field will not be valid until  
a future release. The identity of the Drive Enclosure Environmental Monitoring  
Unit is contained in the device field. The UUID of the specific physical disk drive  
is not identifiable. Check the fault lights of the enclosure associated with this Drive  
Enclosure Environmental Monitoring Unit. Note that in this case the content of  
the fed_class, alpa, and num_times fields are undefined.  
Storage Management Appliance Software Event Code Definitions Application Notes  
31  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
1560  
88030618  
2
6
18  
Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental  
Monitoring Unit has begun updating its code. Do not power down this drive  
enclosure until the code update has completed. The identity of the Drive Enclosure  
Environmental Monitoring Unit is contained in the device field. The Fibre  
Channel port used to communicate with the Drive Enclosure Environmental  
Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal  
Fibre Channel port number used to communicate with the Drive Enclosure  
Environmental Monitoring Unit is contained in the port field. The location of the  
Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and  
dencl_num fields. The rack_num field will not be valid until a future release.  
Note that in this case the content of the fed_class, alpa, and num_times fields are  
undefined.  
1561  
88030619  
2
6
19  
Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental  
Monitoring Unit has completed updating its code. It is now safe to power down  
this drive enclosure. The identity of the Drive Enclosure Environmental Monitoring  
Unit is contained in the device field. The Fibre Channel port used to  
communicate with the Drive Enclosure Environmental Monitoring Unit is  
contained in the cerp_id field. The HSV110 controller internal Fibre Channel  
port number used to communicate with the Drive Enclosure Environmental  
Monitoring Unit is contained in the port field. The location of the Drive Enclosure  
Environmental Monitoring Unit is contained in the rack_num and dencl_num  
fields. The rack_num field will not be valid until a future release. Note that in this  
case the content of the fed_class, alpa, and num_times fields are undefined.  
1562  
8803061a  
6
6
1a  
Storage Cell: %1 Event Code: %2 Description: A physical disk drive has  
exceeded its soft error threshold. The identity of the physical disk drive is  
contained in the device field. The Fibre Channel port used to communicate with  
the physical disk drive is contained in the cerp_id field. The HSV110 controller  
internal Fibre Channel port number used to communicate with the physical disk  
drive is contained in the port field. The arbitrated loop physical address of the  
physical disk drive is contained in the al_pa field. If the bay field contains a  
value other than zero, the location of the physical disk drive is contained in the  
rack_num, dencl_num, and bay fields. If the bay field contains a zero, the  
location of the physical disk drive is unknown and the content of the rack_num  
and dencl_num fields is undefined. The rack_num field will not be valid until a  
future release. Note that in this case the content of the fed_class, cdb, and  
sense_data fields are undefined.  
1563  
8803061b  
2
6
1b  
Storage Cell: %1 Event Code: %2 Description: A HSV110 controller now has an  
address on the enclosure address bus. The HSV110 controller location has been  
identified. The location of the HSV110 controller is contained in the rack_num  
and dencl_num fields. The rack_num field will not be valid until a future release.  
Note that in this case the content of the bay, fed_class, alpa, cerp_id, port, and  
num_times fields are undefined.  
32  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
1564  
8803061c  
3
6
1c  
Storage Cell: %1 Event Code: %2 Description: A non-data exchange frame sent  
to a physical disk drive has timed out. The identity of the physical disk drive is  
contained in the device field. The Fibre Channel port used to communicate with  
the physical disk drive is contained in the cerp_id field. The HSV110 controller  
internal Fibre Channel port number used to communicate with the physical disk  
drive is contained in the port field. The arbitrated loop physical address of the  
physical disk drive is contained in the al_pa field. If the bay field contains a  
value other than zero, the location of the physical disk drive is contained in the  
rack_num, dencl_num, and bay fields. If the bay field contains a zero, the  
location of the physical disk drive is unknown and the content of the rack_num  
and dencl_num fields is undefined. The rack_num field will not be valid until a  
future release. The Fibre Channel Exchange Descriptor class is contained in the  
fed_class field. The command issued to the physical disk drive is contained in the  
cmd field. Note that in this case the content of the error field is undefined.  
2305  
2306  
2307  
88030901  
88030902  
88030903  
2
2
2
9
9
9
1
2
3
Storage Cell: %1 Event Code: %2 Description: The state of the Physical Disk  
Drive identified in the handle field has transitioned to the NORMAL state. The  
value.ul1 field contains the new state: 1 (NORMAL). The value.ul2 field contains  
the old state. The state values that may be in the value.ul2 field are as follows: 2  
= Degraded 3 = Failed 4 = Not present  
Storage Cell: %1 Event Code: %2 Description: The state of the Volume identified  
in the handle field has changed. The value.ul1 field contains the new state. The  
value.ul2 field contains the old state. The state values that may be found in the  
value.ul1 and value.ul2 fields are as follows: 1 = Normal 2 = Migrating 3 =  
Missing 4 = Reconstructing 5 = Completing 6 = Reverting 7 = Failed  
Storage Cell: %1 Event Code: %2 Description: The state of The internal Logical  
Disk associated with the Virtual Disk identified in the handle field has changed.  
The value.ul1 field contains the new state. The value.ul2 field contains the old  
state. The state values that may be found in the value.ul1 and value.ul2 fields are  
as follows: 1 = Normal 2 = Replacement delay in progress 3 = Redundancy lost,  
restore in progress 4 = Redundancy lost, restore stalled 5 = Failed 6 = Creation in  
progress 7 = Snapshot is inoperative due to lack of snapshot space 8 = Deletion  
in progress 9 = Capacity change in progress 10 = Inoperative due to data lost  
2308  
2309  
88030904  
88030905  
2
2
9
9
4
5
Storage Cell: %1 Event Code: %2 Description: The state of the HSV110  
controller identified in the handle field has transitioned to the NORMAL state. The  
value.ul1 field contains the new state: 1 (NORMAL). The value.ul2 field contains  
the old state: 3 (FAILED).  
Storage Cell: %1 Event Code: %2 Description: The state of a battery assembly  
within the HSV110 controller identified in the handle field has changed. The  
value.ul1 field contains the new state. The value.ul2 field contains the old state.  
The state values that may be found in the value.ul1 and value.ul2 fields are as  
follows: 1 = Battery System Hold-up Time is greater than 96 hours 3 = Battery  
System Hold-up Time is greater than 0 and less than 96 hours 5 = Battery System  
Hold-up Time is zero hours  
2310  
88030906  
6
9
6
Storage Cell: %1 Event Code: %2 Description: The state of the Volume identified  
in the handle field has transitioned to the MISSING state. The value.ul1 field  
contains the new state: 3 (MISSING). The value.ul2 field contains the old state.  
The state values that may be found in the value.ul2 field are as follows: 1 =  
Normal 2 = Migrating 4 = Reconstructing 5 = Completing 6 = Reverting 7 =  
Failed  
Storage Management Appliance Software Event Code Definitions Application Notes  
33  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
2311  
88030907  
2
9
7
Storage Cell: %1 Event Code: %2 Description: The state of the Fibre Channel  
port identified in the attribute.value.str field and located on the rear panel of the  
HSV110 controller identified in the handle field has transitioned to the NORMAL  
state. The attribute.type field contains the value 4. The value.ul1 field contains the  
new state: 1 (NORMAL). The value.ul2 field contains the old state: 2 (FAILED).  
Note that the HSV110 controller’s internal identity of the affected Fibre Channel  
port is contained in the secondary_id field.  
2312  
2313  
88030908  
88030909  
3
2
9
9
8
9
Storage Cell: %1 Event Code: %2 Description: The Occupancy Alarm Level  
threshold has been reached for the Disk Group identified in the handle field.  
Storage Cell: %1 Event Code: %2 Description: The Resource Availability state of  
the Volume identified in the handle field has transitioned to the SUFFICIENT state.  
The value.ul1 field contains the new state: 0 (SUFFICIENT). The value.ul2 field  
contains the old state: 1 (INSUFFICIENT).  
2314  
8803090a  
2
9
a
Storage Cell: %1 Event Code: %2 Description: The Data Availability state of the  
Logical Disk identified in the handle field has transitioned to the NORMAL state.  
The value.ul1 field contains the new state: 0 (NORMAL). The value.ul2 field  
contains the old state: 1 (DATA LOST).  
2316  
2317  
8803090c  
8803090d  
2
2
9
9
c
Storage Cell: %1 Event Code: %2 Description: The Snapclone Logical Disk  
identified in the handle field has completed the unsharing operation.  
d
Storage Cell: %1 Event Code: %2 Description: The state of the Quorum Disk flag  
for the Volume identified in the handle field has changed. The value.ul1 field  
contains the new state of the Quorum Disk flag. The value.ul2 field contains the  
old state of the Quorum Disk flag. The state values that may be found in the  
value.ul1 and value.ul2 fields are as follows: 0 = FALSE 1 = TRUE  
2318  
2319  
8803090e  
8803090f  
3
3
9
9
e
f
Storage Cell: %1 Event Code: %2 Description: The temperature trip point for a  
temperature sensor located within the HSV110 controller identified in the handle  
field has been reached.  
Storage Cell: %1 Event Code: %2 Description: A temperature sensor located  
within the HSV110 controller identified in the handle field is approaching its trip  
point. The value.ul1 field contains the current temperature reading from that  
sensor in Celsius. The secondary_id field contains the temperature trip point in  
Celsius.  
2321  
88030911  
2
9
11  
Storage Cell: %1 Event Code: %2 Description: The Blower Present flag for the ‘1’  
blower assembly located within the HSV110 controller identified in the handle  
field has transitioned from the NOT PRESENT to PRESENT state indicating that  
the blower has been reinstalled. The secondary_id field contains the ‘1’ blower  
assembly internal identifier value: 1. The value.ul1 field contains the new state of  
the Blower Present flag: 1 (PRESENT). The value.ul2 field contains the old state of  
the Blower Present flag: 0 (NOT PRESENT).  
2322  
2323  
88030912  
88030913  
6
2
9
9
12  
13  
Storage Cell: %1 Event Code: %2 Description: The ‘1’ blower located within the  
HSV110 controller identified in the handle field is running slower than the lowest  
acceptable speed. The secondary_id field contains the ‘1’ blower assembly  
internal identifier value: 1. The value.ul1 field contains the current speed of the  
‘1’ blower. The value.ul2 field contains the lowest acceptable speed for the ‘1’  
blower.  
Storage Cell: %1 Event Code: %2 Description: One of the voltage sensors  
located within the HSV110 controller identified in the handle field has reported a  
voltage that is out of range. The value.ul1 field contains the out of range voltage  
value. The secondary_id field contains the specific voltage threshold value (i.e.,  
12V, 5V, 3.3V, 2.5V or 2V). Note that the voltages are expressed in  
millivolts--e.g.,12.5V is expressed as 12500.  
34  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
2324  
88030914  
6
9
14  
Storage Cell: %1 Event Code: %2 Description: The state of the Volume identified  
in the handle field has transitioned to the FAILED state. The value.ul1 field  
contains the new state: 7 (FAILED). The value.ul2 field contains the old state. The  
state values that may be found in the value.ul2 fields are as follows: 1 = Normal  
2 = Migrating 3 = Missing 4 = Reconstructing 5 = Completing 6 = Reverting  
2325  
2327  
88030915  
88030917  
6
6
9
9
15  
17  
Storage Cell: %1 Event Code: %2 Description: The state of the HSV110  
controller identified in the handle field has transitioned to the FAILED state. The  
value.ul1 field contains the new state: 3 (FAILED). The value.ul2 field contains the  
old state: 1 (NORMAL).  
Storage Cell: %1 Event Code: %2 Description: The Battery Present flag for  
battery assembly ‘1’ located within the HSV110 controller identified in the  
handle field has changed from PRESENT to NOT PRESENT indicating that the  
battery assembly was removed. The secondary_id field contains the battery  
assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state  
of the Battery Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old  
state of the Battery Present flag: 1 (PRESENT).  
2328  
2329  
88030918  
88030919  
2
2
9
9
18  
19  
Storage Cell: %1 Event Code: %2 Description: The Battery In Use flag for battery  
assembly ‘1’ located within the HSV110 controller identified in the handle field  
has transitioned from the NOT IN USE to IN USE state indicating that the battery  
assembly is functioning properly. The secondary_id field contains the battery  
assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state  
of the Battery In Use flag: 1 (IN USE). The value.ul2 field contains the old state of  
the Battery In Use flag: 0 (NOT IN USE).  
Storage Cell: %1 Event Code: %2 Description: One of the voltage sensors  
located within the HSV110 controller identified in the handle field has reported a  
voltage that indicates that a voltage that was previously out of range has returned  
to the normal range. The value.ul1 field contains the normal range voltage  
value. The secondary_id field contains the voltage threshold value (i.e., 12V, 5V,  
3.3V, 2.5V or 2V). Note that the voltages are expressed in thousands--e.g.,  
12.5V is expressed as 12500.  
2330  
2331  
8803091a  
8803091b  
3
2
9
9
1a  
1b  
Storage Cell: %1 Event Code: %2 Description: The battery assembly voltage  
regulator located within the HSV110 controller identified in the handle field is  
offline.  
Storage Cell: %1 Event Code: %2 Description: The state of the Disk Group  
identified in the handle field has transitioned to the NORMAL state. The value.ul1  
field contains the new Disk Group state: 1 (NORMAL). The value.ul2 field  
contains the old Disk Group state. The state values that may be found in the  
value.ul2 field are as follows: 2 = Disk Group with no redundancy is inoperative  
3 = Disk Group with parity redundancy is inoperative 4 = Disk Group with  
mirrored redundancy is inoperative 5 = Disk Group with no redundancy is  
inoperative, marked for re-use 6 = Disk Group with parity redundancy is  
inoperative, marked for re-use 7 = Disk Group with mirrored redundancy is  
inoperative, marked for re-use  
2332  
8803091c  
2
9
1c  
Storage Cell: %1 Event Code: %2 Description: The Occupancy Alarm Level for  
the Disk Group identified in the handle field has returned to the normal range.  
Storage Management Appliance Software Event Code Definitions Application Notes  
35  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
2333  
2334  
2335  
2336  
2337  
2338  
2339  
8803091d  
8803091e  
8803091f  
88030920  
88030921  
88030922  
88030923  
6
9
1d  
1e  
1f  
Storage Cell: %1 Event Code: %2 Description: The Battery In Use flag for battery  
assembly ‘1’ located within the HSV110 controller identified in the handle field  
has transitioned from the IN USE to NOT IN USE state indicating that the battery  
assembly has malfunctioned. The secondary_id field contains the battery  
assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state  
of the Battery In Use flag: 0 (NOT IN USE). The value.ul2 field contains the old  
state of the Battery In Use flag: 1 (IN USE).  
2
6
2
2
6
6
9
9
9
9
9
9
Storage Cell: %1 Event Code: %2 Description: The Battery Present flag for  
battery assembly ‘1’ located within the HSV110 controller identified in the  
handle field has changed from NOT PRESENT to PRESENT indicating that the  
battery assembly was reinstalled. The secondary_id field contains the battery  
assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state  
of the Battery Present flag: 1 (PRESENT). The value.ul2 field contains the old state  
of the Battery Present flag: 0 (NOT PRESENT).  
Storage Cell: %1 Event Code: %2 Description: The Battery Present flag for  
battery assembly ‘2’ located within the HSV110 controller identified in the  
handle field has changed from PRESENT to NOT PRESENT indicating that the  
battery assembly was removed. The secondary_id field contains the battery  
assembly ‘2’ internal identifier value: 2. The value.ul1 field contains the new state  
of the Battery Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old  
state of the Battery Present flag: 1 (PRESENT).  
20  
21  
22  
23  
Storage Cell: %1 Event Code: %2 Description: The Battery Present flag for  
battery assembly ‘2’ located within the HSV110 controller identified in the  
handle field has changed from NOT PRESENT to PRESENT indicating that the  
battery assembly was reinstalled. The secondary_id field contains the battery  
assembly ‘2’ internal identifier value: 2. The value.ul1 field contains the new state  
of the Battery Present flag: 1 (PRESENT). The value.ul2 field contains the old state  
of the Battery Present flag: 0 (NOT PRESENT).  
Storage Cell: %1 Event Code: %2 Description: The Battery In Use flag for battery  
assembly ‘2’ located within the HSV110 controller identified in the handle field  
has transitioned from the NOT IN USE to IN USE state indicating that the battery  
assembly is functioning properly. The secondary_id field contains the battery  
assembly ‘2’ internal identifier value: 2. The value.ul1 field contains the new state  
of the Battery In Use flag: 1 (IN USE). The value.ul2 field contains the old state of  
the Battery In Use flag: 0 (NOT IN USE).  
Storage Cell: %1 Event Code: %2 Description: The Battery In Use flag for battery  
assembly ‘2’ located within the HSV110 controller identified in the handle field  
has transitioned from the IN USE to NOT IN USE state indicating that the battery  
assembly has malfunctioned. The secondary_id field contains the battery  
assembly ‘2’ internal identifier value: 2. The value.ul1 field contains the new state  
of the Battery In Use flag: 0 (NOT IN USE). The value.ul2 field contains the old  
state of the Battery In Use flag: 1 (IN USE).  
Storage Cell: %1 Event Code: %2 Description: The Blower Present flag for the ‘2’  
blower assembly located within the HSV110 controller identified in the handle  
field has transitioned from the PRESENT to NOT PRESENT state indicating that  
the blower has been removed. The secondary_id field contains the ‘2’ blower  
assembly internal identifier value: 2. The value.ul1 field contains the new state of  
the Blower Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old  
state of the Blower Present flag: 1 (PRESENT).  
36  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
2340  
88030924  
2
9
24  
Storage Cell: %1 Event Code: %2 Description: The Blower Present flag for the ‘2’  
blower assembly located within the HSV110 controller identified in the handle  
field has transitioned from the NOT PRESENT to PRESENT state indicating that  
the blower has been reinstalled. The secondary_id field contains the ‘2’ blower  
assembly internal identifier value: 2. The value.ul1 field contains the new state of  
the Blower Present flag: 1 (PRESENT). The value.ul2 field contains the old state of  
the Blower Present flag: 0 (NOT PRESENT).  
2341  
2342  
88030925  
88030926  
6
6
9
9
25  
26  
Storage Cell: %1 Event Code: %2 Description: The ‘2’ blower located within the  
HSV110 controller identified in the handle field is running slower than the lowest  
acceptable speed. The secondary_id field contains the ‘2’ blower assembly  
internal identifier value: 2. The value.ul1 field contains the current speed of the  
‘2’ blower. The value.ul2 field contains the lowest acceptable speed for the ‘2’  
blower.  
Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present  
flag for the ‘1’ blower/power supply assembly located within the HSV110  
controller identified in the handle field has transitioned from the PRESENT to  
NOT PRESENT state indicating that the blower/power supply has been removed.  
The secondary_id field contains the ‘1’ blower/power supply assembly internal  
identifier value: 1. The value.ul1 field contains the new state of the Blower/Power  
Supply Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state  
of the Blower/Power Supply Present flag: 1 (PRESENT).  
2343  
2344  
2345  
2346  
88030927  
88030928  
88030929  
8803092a  
2
6
2
6
9
9
9
9
27  
28  
29  
2a  
Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present  
flag for the ‘1’ blower/power supply assembly located within the HSV110  
controller identified in the handle field has transitioned from the NOT PRESENT  
to PRESENT state indicating that the blower/power supply has been reinstalled.  
The secondary_id field contains the ‘1’ blower/power supply assembly internal  
identifier value: 1. The value.ul1 field contains the new state of the Blower/Power  
Supply Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the  
Blower/Power Supply Present flag: 0 (NOT PRESENT).  
Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present  
flag for the ‘2’ blower/power supply assembly located within the HSV110  
controller identified in the handle field has transitioned from the PRESENT to  
NOT PRESENT state indicating that the blower/power supply has been removed.  
The secondary_id field contains the ‘2’ blower/power supply assembly internal  
identifier value: 2. The value.ul1 field contains the new state of the Blower/Power  
Supply Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state  
of the Blower/Power Supply Present flag: 1 (PRESENT).  
Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present  
flag for the ‘2’ blower/power supply assembly located within the HSV110  
controller identified in the handle field has transitioned from the NOT PRESENT  
to PRESENT state indicating that the blower/power supply has been reinstalled.  
The secondary_id field contains the ‘2’ blower/power supply assembly internal  
identifier value: 2. The value.ul1 field contains the new state of the Blower/Power  
Supply Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the  
Blower/Power Supply Present flag: 0 (NOT PRESENT).  
Storage Cell: %1 Event Code: %2 Description: The ‘1’ blower/power supply  
located within the HSV110 controller identified in the handle field is running  
slower than the lowest acceptable speed. The secondary_id field contains the ‘1’  
blower/power supply assembly internal identifier value: 1. The value.ul1 field  
contains the current speed of the ‘1’ blower/power supply. The value.ul2 field  
contains the lowest acceptable speed for the ‘1’ blower/power supply.  
Storage Management Appliance Software Event Code Definitions Application Notes  
37  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
2347  
8803092b  
6
9
2b  
Storage Cell: %1 Event Code: %2 Description: The ‘2’ blower/power supply  
located within the HSV110 controller identified in the handle field is running  
slower than the lowest acceptable speed. The secondary_id field contains the ‘2’  
blower/power supply assembly internal identifier value: 2. The value.ul1 field  
contains the current speed of the ‘2’ blower/power supply. The value.ul2 field  
contains the lowest acceptable speed for the ‘2’ blower/power supply.  
2348  
8803092c  
3
9
2c  
Storage Cell: %1 Event Code: %2 Description: The state of a battery assembly  
within the HSV110 controller identified in the handle field has transitioned to the  
Battery System Hold-up Time is zero hours state. The value.ul1 field contains the  
new state 3: (Battery System Hold-up Time is zero hours). The value.ul2 field  
contains the old state. The state values that may be found in the value.ul2 field  
are as follows: 1 = Battery System Hold-up Time is greater than 96 hours 3 =  
Battery System Hold-up Time is greater than 0 and less than 96 hours  
2349  
2350  
8803092d  
8803092e  
6
2
9
9
2d  
2e  
Storage Cell: %1 Event Code: %2 Description: The Resource Availability state of  
the Volume identified in the handle field has transitioned to the INSUFFICIENT  
state. The value.ul1 field contains the new state: 1 (INSUFFICIENT). The value.ul2  
field contains the old state: 0 (SUFFICIENT).  
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
in the handle field rejected a login attempt. The value.ul1 and value.ul2 fields  
contain words [0] and [1], respectively, of the World Wide Name of the host  
adapter that originated the rejected login attempt. The secondary_id field  
contains the reason for the rejection as follows: 50 = The host is already logged  
in 101 = Maximum number of logins is exceeded 102 = Invalid cookie was sent  
106 = The password is not set on the HSV110 controller  
2351  
2352  
8803092f  
88030930  
2
2
9
9
2f  
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
in the handle field processed a StorageCell Management Interface command  
with the result of non-success return code. The value.ul1 field contains the  
command type. The value.ul2 field contains the return code.  
30  
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
in the handle field has updated the physical disk drive map for the loop pair  
identified in the secondary_id field. The value.ul1 field contains the new internal  
map generation number. The value.ul2 field contains the old internal map  
generation number.  
2353  
2354  
2355  
2356  
88030931  
88030932  
88030933  
88030934  
6
6
2
2
9
9
9
9
31  
32  
33  
34  
Storage Cell: %1 Event Code: %2 Description: The state of the Physical Disk  
Drive identified in the handle field has transitioned to the DEGRADED state. The  
value.ul1 field contains the new state: 2 (DEGRADED). The value.ul2 field  
contains the old state. The state values that may be in the value.ul2 field are as  
follows: 1 = Normal 3 = Failed 4 = Not present  
Storage Cell: %1 Event Code: %2 Description: The state of the Physical Disk  
Drive identified in the handle field has transitioned to the FAILED state. The  
value.ul1 field contains the new state: 3 (FAILED). The value.ul2 field contains the  
old state. The state values that may be in the value.ul2 field are as follows: 1 =  
Normal 2 = Degraded 4 = Not present  
Storage Cell: %1 Event Code: %2 Description: The Derived Unit identified in the  
handle field was created. The add_handle field contains the identity of the  
Storage System Virtual Disk that is associated with that Derived Unit. The  
atribute.value.obj field contains the identity of the Virtual Disk associated with  
that Derived Unit.  
Storage Cell: %1 Event Code: %2 Description: The internal Logical Disk  
associated with the Virtual Disk identified in the handle field was created.  
38  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
2357  
88030935  
2
9
35  
Storage Cell: %1 Event Code: %2 Description: The Disk Group identified in the  
handle field was created.  
2358  
88030936  
2
2
9
9
36  
Storage Cell: %1 Event Code: %2 Description: The Physical Disk Drive identified  
in the handle field was discovered. The enclosure number and bay number where  
the Physical Disk Drive is located are contained in the attribute.value.u32[0] and  
attribute.value.u32[1] fields, respectively. The attribute.type field contains the  
value 1.  
2359  
88030937  
37  
Storage Cell: %1 Event Code: %2 Description: The Presented Unit identified in  
the handle field was created. The add_handle field contains the identity of the  
Storage System Virtual Disk that is associated with the Presented Unit. This  
Presented Unit is associated with the Virtual Disk identified in the  
attribute.value.obj.handle field.  
2360  
2361  
2362  
88030938  
88030939  
8803093a  
2
2
2
9
9
9
38  
39  
3a  
Storage Cell: %1 Event Code: %2 Description: The Storage System Host path  
identified in the handle field was created.  
Storage Cell: %1 Event Code: %2 Description: The Storage System Virtual Disk  
identified in the handle field was created.  
Storage Cell: %1 Event Code: %2 Description: The Volume identified in the  
handle field was created. The add_handle field contains the identity of the  
Physical Disk Drive that is associated with the Volume.  
2363  
8803093b  
2
9
3b  
Storage Cell: %1 Event Code: %2 Description: The Derived Unit identified in the  
handle field was deleted. The add_handle field contains the identity of the  
Storage System Virtual Disk that was associated with the Derived Unit. This  
Derived Unit is associated with the Virtual Disk identified in the  
attribute.value.obj.handle field.  
2364  
2365  
2366  
8803093c  
8803093d  
8803093e  
2
2
6
9
9
9
3c  
3d  
3e  
Storage Cell: %1 Event Code: %2 Description: The internal Logical Disk  
associated with the Virtual Disk identified in the handle field was deleted.  
Storage Cell: %1 Event Code: %2 Description: The Disk Group identified in the  
handle field was deleted.  
Storage Cell: %1 Event Code: %2 Description: The Physical Disk Drive identified  
in the handle field has disappeared. The enclosure number and bay number  
where the Physical Disk Drive was located are contained in the  
attribute.value.u32[0] and attribute.value.u32[1] fields, respectively. The  
attribute.type field contains the value 1.  
2367  
8803093f  
2
9
3f  
Storage Cell: %1 Event Code: %2 Description: The Presented Unit identified in  
the handle field was deleted. The add_handle field contains the identity of the  
Storage System Virtual Disk that was associated with the Presented Unit. This  
Presented Unit is associated with the Virtual Disk identified in the  
attribute.value.obj.handle field.  
2368  
2369  
88030940  
88030941  
2
2
9
9
40  
41  
Storage Cell: %1 Event Code: %2 Description: The Storage System Host path  
identified in the handle field was deleted.  
Storage Cell: %1 Event Code: %2 Description: The Storage System Virtual Disk  
identified in the handle field was deleted. The Storage System Virtual Disk is  
associated with the Virtual Disk identified in the add_handle field.  
2370  
88030942  
6
9
42  
Storage Cell: %1 Event Code: %2 Description: The Snapshot Logical Disk  
identified in the handle field has been marked inoperative due to the Disk Group  
being out of space for additional storage allocation.  
Storage Management Appliance Software Event Code Definitions Application Notes  
39  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
2371  
2372  
2373  
88030943  
88030944  
88030945  
2
9
43  
44  
45  
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
in the handle field has joined the Storage System. If the handle field is zero, the  
HSV110 controller identity could not be obtained due to an unexpected state  
transition.  
6
2
9
9
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
in the handle field has left the Storage System. If the handle field is zero, the  
HSV110 controller identity could not be obtained due to an unexpected state  
transition.  
Storage Cell: %1 Event Code: %2 Description: The Storage System identified by  
the handle field was deleted by the HSV110 controller identified in the  
add_handle field. If the handle field or add_handle field is zero, the  
corresponding identity could not be obtained due to an unexpected state  
transition.  
2405  
88030965  
2
9
65  
Storage Cell: %1 Event Code: %2 Description: The Host Operating System mode  
of the Storage System Host identified in the handle field has changed. The  
old_attr.type and new_attr.type fields contain the value 1. The  
old_attr.value.u32[0] field contains the old Host Operating System mode. The  
new_attr.value.u32[0] field contains the new Host Operating System mode. The  
values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0]  
fields are as follows: 0 = Unknown 1 = User defined 2 = Unused 3 = WINNT  
with SecurePath 4 = VMS 5 = TRU64 UNIX 6 = Sun UNIX 7 = NetWare 8 = HP  
9 = IBM 10 = LINUX 11 = SCO UNIX  
2406  
2407  
88030966  
88030967  
2
2
9
9
66  
67  
Storage Cell: %1 Event Code: %2 Description: Time was set on the Storage  
System identified in the handle field.  
Storage Cell: %1 Event Code: %2 Description: The LUN of the Presented Unit  
identified in the handle field has changed. The old_attr.type field and the  
new_attr.type fields contain the value 1. The old_attr.value.u32[0..1] fields  
contain the value of the old LUN. The new_attr.value.u32[0..1] fields contain the  
value of the new LUN. The secondary_id field contains the noid portion of the  
handle for the Storage System Virtual Disk associated with the Presented Unit.  
This Presented Unit is associated with the Virtual Disk identified in the  
add_handle field.  
2408  
2409  
88030968  
88030969  
2
2
9
9
68  
69  
Storage Cell: %1 Event Code: %2 Description: The Device Addition Policy of the  
Storage System identified in the handle field has changed. The old_attr.type field  
and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field  
contains the old Device Addition Policy. The new_attr.value.u32[0] field contains  
the new Device Addition Policy. The policy values that may be found in the  
old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 1 =  
Manual policy 2 = Automatic policy  
Storage Cell: %1 Event Code: %2 Description: The Quiescent state of the  
Storage System Virtual Disk identified in the handle field has changed. The  
old_attr.type field and the new_attr.type fields contain the value 1. The  
old_attr.value.u32[0] field contains the old Quiescent state. The  
new_attr.value.u32[0] field contains the new Quiescent state. The state values  
that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields  
are as follows: 0 = FALSE 1 = TRUE This Storage System Virtual Disk is associated  
with the Virtual Disk identified in the add_handle field.  
40  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
2410  
8803096a  
2
9
6a  
Storage Cell: %1 Event Code: %2 Description: The Enabled/Disabled state of  
the Storage System Virtual Disk identified in the handle field has changed. The  
old_attr.type field and the new_attr.type fields contain the value 1. The  
old_attr.value.u32[0] field contains the old Enabled/Disabled state. The  
new_attr.value.u32[0] field contains the new Enabled/Disabled state. The state  
values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0]  
fields are as follows: 1 = Disabled 2 = Enabled This Storage System Virtual Disk  
is associated with the Virtual Disk identified in the add_handle field.  
2411  
8803096b  
2
9
6b  
Storage Cell: %1 Event Code: %2 Description: The Cache Policy of the Storage  
System Virtual Disk identified in the handle field has changed. The old_attr.type  
field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0]  
field contains the old Write Cache Policy. The new_attr.value.u32[0] field  
contains the new Write Cache Policy. The policy values that may be found in the  
old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 1 =  
Writethrough 2 = Writeback The old_attr.value.u32[1] field contains the old  
Read Cache Policy. The new_attr.value.u32[1] field contains the new Read Cache  
Policy. The policy values that may be found in the old_attr.value.u32[1] and  
new_attr.value.u32[1] fields are as follows: 1 = Read cache on 2 = Read cache  
off The old_attr.value.u32[2] field contains the old Cache Mirroring Policy. The  
new_attr.value.u32[2] field contains the new Cache Mirroring Policy. The policy  
values that may be found in the old_attr.value.u32[2] and new_attr.value.u32[ 2]  
fields are as follows: 1 = Mirror 2 = No mirror This Storage System Virtual Disk is  
associated with the Virtual Disk identified in the add_handle field.  
2412  
2413  
2414  
8803096c  
8803096d  
8803096e  
2
2
2
9
9
9
6c  
6d  
6e  
Storage Cell: %1 Event Code: %2 Description: The Usage state of the Volume  
identified in the handle field has changed. The old_attr.value.u32[0] field  
contains the old Usage state. The new_attr.value.u32[0] field contains the new  
Usage state. The Usage state values that may be found in the  
old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 1 = Disk  
Group 2 = Reserved  
Storage Cell: %1 Event Code: %2 Description: The Disk Failure Protection Level  
of the Disk Group identified in the handle field has changed. The old_attr.type  
and new_attr.type fields contain the value 1. The old_attr.value.u32[0] field  
contains the old number of physical disk drives available for use. The  
new_attr.value.u32[0] field contains the new number of physical disk drives  
available for use.  
Storage Cell: %1 Event Code: %2 Description: The Write Protected state of the  
Derived Unit identified in the handle field has changed. The secondary_id field  
contains the noid portion of the handle for the Storage System Virtual Disk  
associated with the Derived Unit. The old_attr.type field and the new_attr.type  
fields contain the value 1. The old_attr.value.u32[0] field contains the old Write  
Protected state. The new_attr.value.u32[0] field contains the new Write Protected  
state. The Write Protected state values that may be found in the  
old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 0 = Write  
protect off 1 = Write protect on This Derived Unit is associated with the Virtual  
Disk identified in the add_handle field.  
2416  
88030970  
3
9
70  
Storage Cell: %1 Event Code: %2 Description: The Physical Disk Drive identified  
in the handle field has experienced numerous communication failures on a  
particular Fibre Channel port.  
Storage Management Appliance Software Event Code Definitions Application Notes  
41  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
2417  
88030971  
2
9
71  
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
in the handle field received a request to shutdown. The old_attr.type field and the  
new_attr.type fields contain the value 1. The old_attr.value.u32[0] field indicates  
the type of restart that was requested as follows: 0 = None -- no restart 1 =  
Regular -- full restart, host system connectivity is lost until the controller returns to  
normal operation 2 = Fast -- resynchronization, restart of the controller in a  
manner that has little or no impact on host system connectivity The  
old_attr.value.u32[1] field indicates whether the other HSV110 controller of the  
pair was requested to remain operational or to also shutdown as follows: 0 =  
Remain operational 1 = Coupled shutdown The old_attr.value.u32[2] field  
indicates whether the HSV110 controller was requested to remain in the power  
on state or power itself off as follows: 0 = Remain in the power on state 1 =  
Power itself off The old_attr.value.u32[3] field value indicates whether the  
Physical Disk Drive enclosure(s) was requested to remain in the power on state or  
to be powered off as follows: 0 = Remain in the power on state 1 = Powered off  
The old_attr.value.u32[4] field value indicates whether the battery assemblies  
located within the HSV110 controller were requested to be enabled or disabled  
as follows: 0 = Enabled 1 = Disabled The old_attr.value.u32[5] field contains the  
number of seconds the shutdown operation was requested to be delayed.  
2418  
88030972  
2
9
72  
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
in the handle field has completed its shutdown preparations. The old_attr.type  
field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0]  
field value indicates the result of the HSV110 controller Cache Memory shutdown  
operation as follows: 1 = Success 2 = Failure 3 = Not applicable The  
old_attr.value.u32[1] field contains the internal Storage System Management  
Interface cache shutdown status code. The old_attr.value.u32[2] field value  
indicates the result of the Physical Disk Drive enclosure(s) power off operation as  
follows: 1 = Success 2 = Failure 3 = Not applicable The old_attr.value.u32[3]  
field contains the internal Storage System Management Interface Physical Disk  
Drive enclosure(s) power off status code. The old_attr.value.u32[4] field value  
indicates the result of the battery assemblies disable operation as follows: 1 =  
Success 2 = Failure 3 = Not applicable <P > The old_attr.value.u32[5] field value  
indicates the battery assemblies disable operation failure mode as follows: 0 =  
No failure indicated. 1 = Failed only on the HSV110 controller identified in the  
handle field. 2 = Failed only on the other HSV110 controller of the pair. 3 =  
Failed on both HSV110 controllers.  
2504  
2505  
880309c8  
880309c9  
6
6
9
9
c8  
c9  
Storage Cell: %1 Event Code: %2 Description: The Data Availability state of the  
internal Logical Disk associated with the Virtual Disk identified in the handle field  
has has transitioned to the DATA LOST state. The value.ul1 field contains the new  
state: 1 (DATA LOST). The value.ul2 field contains the old state: 0 (NORMAL).  
Storage Cell: %1 Event Code: %2 Description: The state of the Disk Group  
identified in the handle field has transitioned to an INOPERATIVE state. The  
value.ul1 field contains the new Disk Group state. The value.ul2 field contains the  
old Disk Group state. The state values that may be found in the value.ul1 and  
value.ul2 fields are as follows: 1 = Normal 2 = Disk Group with no redundancy  
is inoperative 3 = Disk Group with parity redundancy is inoperative 4 = Disk  
Group with mirrored redundancy is inoperative 5 = Disk Group with no  
redundancy is inoperative, marked for re-use 6 = Disk Group with parity  
redundancy is inoperative, marked for re-use 7 = Disk Group with mirrored  
redundancy is inoperative, marked for re-use  
42  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
2506  
2507  
2508  
880309ca  
880309cb  
880309cc  
6
9
ca  
cb  
cc  
Storage Cell: %1 Event Code: %2 Description: The state of the internal Logical  
Disk associated with the Virtual Disk identified in the handle field has transitioned  
to the FAILED state. The value.ul1 field contains the new state: 5 (FAILED). The  
value.ul2 field contains the old state. The state values that may be found in the  
value.ul2 field are as follows: 1 = Normal 2 = Replacement delay in progress 3 =  
Redundancy lost, restore in progress 4 = Redundancy lost, restore stalled 6 =  
Creation in progress 7 = Snapshot is inoperative due to lack of snapshot space 8  
= Deletion in progress 9 = Capacity change in progress 10 = Inoperative due to  
data lost  
6
6
9
9
Storage Cell: %1 Event Code: %2 Description: The state of the internal Logical  
Disk associated with the Virtual Disk identified in the handle field has transitioned  
to the SNAPSHOT OVERCOMMIT state. The value.ul1 field contains the new  
state: 7 (SNAPSHOT OVERCOMMIT). The value.ul2 field contains the old state.  
The state values that may be found in the value.ul2 field are as follows: 1 =  
Normal 2 = Replacement delay in progress 3 = Redundancy lost, restore in  
progress 4 = Redundancy lost, restore stalled 5 = Failed 6 = Creation in progress  
8 = Deletion in progress 9 = Capacity change in progress 10 = Inoperative due  
to device data lost  
Storage Cell: %1 Event Code: %2 Description: The state of the internal Logical  
Disk associated with the Virtual Disk identified in the handle field has transitioned  
to the DEVICE DATA LOST state. The value.ul1 field contains the new state: 10  
(DEVICE DATA LOST). The value.ul2 field contains the old state. The state values  
that may be found in the value.ul2 field are as follows: 1 = Normal 2 =  
Replacement delay in progress 3 = Redundancy lost restore, in progress 4 =  
Redundancy lost restore, stalled 5 = Failed 6 = Creation in progress 7 =  
Snapshot is inoperative due to lack of snapshot space 8 = Deletion in progress 9  
= Capacity change in progress  
2509  
2510  
880309cd  
880309ce  
6
2
9
9
cd  
ce  
Storage Cell: %1 Event Code: %2 Description: The state of the Fibre Channel  
port identified in the attribute.value.str field and located on the rear panel of the  
HSV110 controller identified in the handle field has transitioned to the FAILED  
state. The attribute.type field contains the value 4. The value.ul1 field contains  
the new state: 2 (FAILED). The value.ul2 field contains the old state: 1  
(NORMAL). Note that the HSV110 controller’s internal identity of the affected  
Fibre Channel port is contained in the secondary_id field.  
Storage Cell: %1 Event Code: %2 Description: The state of the Disk Group  
identified in the handle field has transitioned to an INOPERATIVE MARKED state.  
The value.ul1 field contains the new Disk Group state. The value.ul2 field  
contains the old Disk Group state. The state values that may be found in the  
value.ul1 and value.ul2 fields are as follows: 1 = Normal 2 = Disk Group with no  
redundancy is inoperative 3 = Disk Group with parity redundancy is inoperative  
4 = Disk Group with mirrored redundancy is inoperative 5 = Disk Group with no  
redundancy is inoperative, marked for re-use 6 = Disk Group with parity  
redundancy is inoperative, marked for re-use 7 = Disk Group with mirrored  
redundancy is inoperative, marked for re-use  
2511  
2512  
880309cf  
880309d0  
3
2
9
9
cf  
Storage Cell: %1 Event Code: %2 Description: The state of the Physical Disk  
Drive identified in the handle field has transitioned to the NOT PRESENT state.  
The value.ul1 field contains the new state: 4 (NOT PRESENT). The value.ul2 field  
contains the old state. The state values that may be in the value.ul2 field are as  
follows: 1 = Normal 2 = Degraded 3 = Failed  
d0  
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
in the handle field no longer needs attention.  
Storage Management Appliance Software Event Code Definitions Application Notes  
43  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
2513  
880309d1  
6
9
d1  
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
in the handle field needs attention.  
2514  
880309d2  
6
9
d2  
Storage Cell: %1 Event Code: %2 Description: The Blower Present flag for the ‘1’  
blower assembly located within the HSV110 controller identified in the handle  
field has transitioned from the PRESENT to NOT PRESENT state indicating that  
the blower has been removed. The secondary_id field contains the ‘1’ blower  
assembly internal identifier value: 1. The value.ul1 field contains the new state of  
the Blower Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old  
state of the Blower Present flag: 1 (PRESENT).  
2816  
88030b00  
2
b
0
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified  
by the node_name field has begun a resynchronization operation (i.e., a restart  
of the controllers in a manner that has little or no impact on host system  
connectivity). The information.pc field contains the program counter of  
resynchronization operation initiator. The information.flags field contains reboot  
flags value. The information.code field contains the resynchronization operation  
event code value.  
3072  
3073  
88030c00  
88030c01  
2
6
c
c
0
1
Storage Cell: %1 Event Code: %2 Description: The specified destination virtual  
disk has successfully completed a full copy. The following fields are not valid:  
status, blocks, vda.  
Storage Cell: %1 Event Code: %2 Description: The specified source virtual disk  
has transitioned to the logging state, because the alternate site is not accessible  
or the DRM group is suspended. The following fields are not valid: status, blocks,  
vda, port, side.  
3074  
3076  
88030c02  
88030c04  
6
6
c
c
2
4
Storage Cell: %1 Event Code: %2 Description: The specified source virtual disk  
has transitioned to the logging state, because the destination virtual disk is not  
accessible. The following fields are not valid: status, blocks, vda, port, side.  
Storage Cell: %1 Event Code: %2 Description: The specified source virtual disk  
has been forced inoperative due to a failsafe locked condition. Either the  
destination is not accessible or a member virtual disk in the group has gone  
inoperative. The following fields are not valid: status, blocks, vda, port, side.  
3077  
3078  
3079  
3080  
3081  
88030c05  
88030c06  
88030c07  
88030c08  
88030c09  
6
6
6
6
6
c
c
c
c
c
5
6
7
8
9
Storage Cell: %1 Event Code: %2 Description: The specified source virtual disk  
has been forced inoperative due to a failsafe locked condition. Either the  
destination is not accessible or a member virtual disk in the group has gone  
inoperative. The following fields are not valid: status, blocks, vda, port, side.  
Storage Cell: %1 Event Code: %2 Description: An unrecoverable read error  
occurred on the specified source virtual disk during the full copy. The virtual disk  
address (vda) specified indicates the first block in error. The full copy was  
terminated.  
Storage Cell: %1 Event Code: %2 Description: A full copy terminated prior to  
completion. A remote copy error occurred, due to an inaccessible alternate site.  
The virtual disk address specified indicates the first block in error. The full copy  
will continue when the destination is restored.  
Storage Cell: %1 Event Code: %2 Description: A full copy terminated prior to  
completion. A remote copy error occurred, due to an inaccessible destination  
virtual disk. The virtual disk address specified indicates the first block in error.  
The full copy will continue when the destination is restored.  
Storage Cell: %1 Event Code: %2 Description: The specified log logical disk has  
been reset due to insufficient storage space. The destination has been marked  
for a full copy. The following fields are not valid: status, blocks, vda, port, side.  
44  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
3082  
3084  
3087  
3088  
3089  
3090  
3092  
88030c0a  
88030c0c  
88030c0f  
88030c10  
88030c11  
88030c12  
88030c14  
2
c
a
Storage Cell: %1 Event Code: %2 Description: The specified log logical disk has  
been reset due to site failover. The following fields are not valid: status, blocks,  
vda.  
2
2
2
2
2
6
c
c
c
c
c
c
c
Storage Cell: %1 Event Code: %2 Description: The specified destination virtual  
disk has successfully completed a merge. The following fields are not valid:  
status, blocks, vda.  
f
Storage Cell: %1 Event Code: %2 Description: The specified virtual disk is no  
longer failsafe locked. The following fields are not valid: status, blocks, vda, port,  
side.  
10  
11  
12  
14  
Storage Cell: %1 Event Code: %2 Description: The specified destination virtual  
disk has been marked for a full copy. The following fields are not valid: status,  
blocks, vda.  
Storage Cell: %1 Event Code: %2 Description: This site has just discovered that a  
site failover has taken place. This group is transitioning from a source role to a  
destination role. The following fields are not valid: status, blocks, vda.  
Storage Cell: %1 Event Code: %2 Description: This site has just discovered that a  
site failover has taken place. This group is transitioning from a destination role to  
a source role. The following fields are not valid: status, blocks, vda.  
Storage Cell: %1 Event Code: %2 Description: The specified destination DRM  
group was not found. The destination group appears to have been deleted by  
the user after a site failover, therefore this dangling DRM source group should  
likewise be deleted.  
3328  
3329  
88030d00  
88030d01  
6
6
d
d
0
1
Storage Cell: %1 Event Code: %2 Description: Unrecognized event reported by  
a Drive Enclosure Environmental Monitoring Unit. The event was reported by the  
Drive Enclosure Environmental Monitoring Unit located in the drive enclosure  
identified in the dencl_num field within the rack identified in the rack_num field.  
The rack_num field will not be valid until a future release. The content of the  
alarm_error_code field could not be translated into a known event.  
Storage Cell: %1 Event Code: %2 Description: A physical disk drive that is not  
Fibre Channel compatible or cannot operate at the link rate established by the  
drive enclosure I/O modules was detected. This problem was detected by the  
Drive Enclosure Environmental Monitoring Unit located in the drive enclosure  
identified in the dencl_num field within the rack identified in the rack_num field  
during spin up of the physical disk drive installed in the drive enclosure bay  
identified in the alarm_error_code.field.en field. The rack_num field will not be  
valid until a future release.  
3330  
3331  
88030d02  
88030d03  
3
3
d
d
2
3
Storage Cell: %1 Event Code: %2 Description: A physical disk drive is  
improperly installed or missing. This could affect the drive enclosure air flow and  
cause an over temperature condition. This problem was detected by the Drive  
Enclosure Environmental Monitoring Unit located in the drive enclosure identified  
in the dencl_num field within the rack identified in the rack_num field. The  
rack_num field will not be valid until a future release. The affected drive enclosure  
bay is identified in the alarm_error_code.field.en field.  
Storage Cell: %1 Event Code: %2 Description: A physical disk drive was  
removed while software-activated drive locking was enabled on a drive enclosure  
that does not support drive locking. This problem was detected by the Drive  
Enclosure Environmental Monitoring Unit located in the drive enclosure identified  
in the dencl_num field within the rack identified in the rack_num field. The  
rack_num field will not be valid until a future release. The affected drive enclosure  
bay is identified in the alarm_error_code.field.en field.  
Storage Management Appliance Software Event Code Definitions Application Notes  
45  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
3332  
88030d04  
6
d
4
Storage Cell: %1 Event Code: %2 Description: A physical disk drive that is  
capable of operating at the loop link rate established by the drive enclosure I/O  
module was found to be running at a different rate. This problem was detected  
by the Drive Enclosure Environmental Monitoring Unit located in the drive  
enclosure identified in the dencl_num field within the rack identified in the  
rack_num field. The rack_num field will not be valid until a future release. The  
affected physical disk drive is installed in the drive enclosure bay identified in the  
alarm_error_code.field.en field. The Fibre Channel loop on which the problem  
was detected is identified by the content of the alarm_error_code.field.ec field as  
follows: 4 = loop A 5 = loop B  
3379  
3380  
88030d33  
88030d34  
3
6
d
d
33  
34  
Storage Cell: %1 Event Code: %2 Description: The AC input to a drive enclosure  
power supply has been lost. This makes the remaining power supply a single  
point of failure. This problem was detected by the Drive Enclosure Environmental  
Monitoring Unit located in the drive enclosure identified in the dencl_num field  
within the rack identified in the rack_num field. The rack_num field will not be  
valid until a future release. The location of the affected power supply (1 or 2) is  
identified in the alarm_error_code.field.en field.  
Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply is  
improperly installed or missing. This could affect the drive enclosure air flow and  
cause an over temperature condition. The operational power supply will  
automatically shut down after a short period of time, thereby disabling the drive  
enclosure. This condition remains active until either the problem is corrected, or  
the operational power supply shuts down, whichever occurs first. This problem  
was detected by the Drive Enclosure Environmental Monitoring Unit located in the  
drive enclosure identified in the dencl_num field within the rack identified in the  
rack_num field. The rack_num field will not be valid until a future release. The  
location of the affected power supply (1 or 2) is identified in the  
alarm_error_code.field.en field.  
3381  
88030d35  
6
d
35  
Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply  
component has failed. This problem was detected by the Drive Enclosure  
Environmental Monitoring Unit located in the drive enclosure identified in the  
dencl_num field within the rack identified in the rack_num field. The rack_num  
field will not be valid until a future release. The location of the affected power  
supply (1 or 2) is identified in the alarm_error_code.field.en field.  
46  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
3399  
88030d47  
6
d
47  
Storage Cell: %1 Event Code: %2 Description: A drive enclosure blower is not  
operating properly. This could affect the drive enclosure air flow and cause an  
over temperature condition. This problem was detected by the Drive Enclosure  
Environmental Monitoring Unit located in the drive enclosure identified in the  
dencl_num field within the rack identified in the rack_num field.The rack_num  
field will not be valid until a future release. The location of the affected blower (1  
or 2) is identified in the alarm_error_code.field.en field. The cause of the  
improper operation is described by the content of the alarm_error_code.field.ec  
field as follows: 1 = The blower is operating at a speed that is outside of the Drive  
Enclosure Environmental Monitoring Unit specified range, possibly because of a  
bearing problem. 2 = The blower is operating at a speed that is significantly  
outside of the Drive Enclosure Environmental Monitoring Unit specified range,  
possibly because of a bearing problem. 3 = The blower has stopped.  
NOTE: The other blower (if operational) now operates at high speed and is a  
single point of failure. A single blower operating at high speed can provide  
sufficient air flow to cool an enclosure and the elements for up to 100 hours.  
However, operating an enclosure at temperatures approaching an overheating  
threshold can damage elements and may reduce the MTBF of a specific element.  
Compaq therefore recommends immediate replacement of the defective blower.  
4 = The power supply reported an internal blower error.  
3403  
3404  
88030d4b  
88030d4c  
6
6
d
d
4b  
4c  
Storage Cell: %1 Event Code: %2 Description: A drive enclosure blower is  
improperly installed or missing. This affects the drive enclosure air flow and can  
cause an over temperature condition. This problem was detected by the Drive  
Enclosure Environmental Monitoring Unit located in the drive enclosure identified  
in the dencl_num field within the rack identified in the rack_num field. The  
rack_num field will not be valid until a future release. The location of the affected  
blower (1 or 2) is identified in the alarm_error_code.field.en field.  
Storage Cell: %1 Event Code: %2 Description: Both drive enclosure blowers are  
missing. This severely affects the drive enclosure air flow and can cause an over  
temperature condition. The operational power supply(s) will automatically shut  
down after a short period of time, thereby disabling the drive enclosure. This  
condition remains active until either the problem is corrected, or the operational  
power supply(s) shut down, whichever occurs first. This problem was detected by  
the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure  
identified in the dencl_num field within the rack identified in the rack_num field.  
The rack_num field will not be valid until a future release. Note that this event is  
preceded by a ‘drive enclosure blower is improperly installed or missing’ event  
that identifies the location of the first missing blower. The location of the second  
missing blower (1 or 2) is identified in the alarm_error_code.field.en field of this  
event.  
Storage Management Appliance Software Event Code Definitions Application Notes  
47  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
3419  
88030d5b  
3
d
5b  
Storage Cell: %1 Event Code: %2 Description: A drive enclosure temperature  
sensor out of range condition has been reported by one of the drive enclosure  
elements. This problem was detected by the Drive Enclosure Environmental  
Monitoring Unit located in the drive enclosure identified in the dencl_num field  
within the rack identified in the rack_num field. The rack_num field will not be  
valid until a future release. The location of the temperature sensor (1 through 11)  
is identified in the alarm_error_code.field.en field as follows: 1 = Power Supply 1  
Exhaust 2 = Power Supply 2 Exhaust 3 = Drive Enclosure Environmental  
Monitoring Unit 4 = Drive Bay 1 5 = Drive Bay 2 6 = Drive Bay 3 7 = Drive  
Bay 4 8 = Drive Bay 5 9 = Drive Bay 6 A = Drive Bay 7 B = Drive Bay 8 C =  
Drive Bay 9 D = Drive Bay 10 E = Drive Bay 11 F = Drive Bay 12 10 = Drive  
Bay 13 11 = Drive Bay 14 The temperature sensor out of range condition is  
described by the content of the alarm_error_code.fie ld.ec field as follows: 1 =  
The element temperature is approaching, but has not reached, the high  
temperature CRITICAL threshold. Continued operation under these conditions  
may result in a CRITICAL condition and may reduce an element’s MTBF. 2 = The  
element temperature is above the high temperature CRITICAL threshold.  
Continued operation under these conditions may result in element failure. 3 =  
The element temperature is approaching, but has not reached, the low  
temperature CRITICAL threshold. Continued operation under these conditions  
may result in a CRITICAL condition and may reduce an element’s MTBF. 4 = The  
element temperature has reached the low temperature CRITICAL threshold.  
Continued operation under these conditions may result in element failure. The  
actual temperature threshold values can be found in the HSV element manager  
GUI.  
3423  
88030d5f  
6
d
5f  
Storage Cell: %1 Event Code: %2 Description: The average temperature of two  
of the three temperature sensor groups (i.e., Drive Enclosure Environmental  
Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level.  
The operational power supply(s) will automatically shut down after a short period  
of time, thereby disabling the drive enclosure. This condition remains active until  
either the problem is corrected, or the operational power supply(s) shut down,  
whichever occurs first. This problem was detected by the Drive Enclosure  
Environmental Monitoring Unit located in the drive enclosure identified in the  
dencl_num field within the rack identified in the rack_num field. The rack_num  
field will not be valid until a future release. Note that in this case the content of  
the alarm_error_code.field.en field is undefined. The actual temperature  
threshold values can be found in the HSV element manager GUI.  
3439  
88030d6f  
3
d
6f  
Storage Cell: %1 Event Code: %2 Description: An internal Drive Enclosure  
Environmental Monitoring Unit error has occurred. This problem was detected by  
the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure  
identified in the dencl_num field within the rack identified in the rack_num field.  
The rack_num field will not be valid until a future release. The  
alarm_error_code.field.en field contains the value 1 signifying that the Drive  
Enclosure Environmental Monitoring Unit is the affected element. The cause of  
the improper operation is described by the content of the  
alarm_error_code.field.ec field as follows: 1 = An internal Drive Enclosure  
Environmental Monitoring Unit clock error has occurred. 2 = The Inter-IC (I2C)  
bus is not processing data and the Drive Enclosure Environmental Monitoring  
Unit is unable to monitor or report the status of the elements or enclosures. 5 = A  
Backplane NVRAM error has occurred.  
48  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
3441  
88030d71  
2
d
71  
Storage Cell: %1 Event Code: %2 Description: An internal Drive Enclosure  
Environmental Monitoring Unit error has occurred. This problem was detected by  
the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure  
identified in the dencl_num field within the rack identified in the rack_num field.  
The rack_num field will not be valid until a future release. The  
alarm_error_code.field.en field contains the value 1 signifying that the Drive  
Enclosure Environmental Monitoring Unit is the affected element. The cause of  
the improper operation is described by the content of the  
alarm_error_code.field.ec field as follows: 3 = A drive enclosure power supply  
was shut down. 16 = The Drive Enclosure Environmental Monitoring Unit ESI data  
has been corrupted.  
3442  
88030d72  
3
d
72  
Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental  
Monitoring Unit is unable to collect data for the SCSI-3 Engineering Services  
(SES) page. This problem was detected by the Drive Enclosure Environmental  
Monitoring Unit located in the drive enclosure identified in the dencl_num field  
within the rack identified in the rack_num field. The rack_num field will not be  
valid until a future release. The alarm_error_code.field.en field contains the value  
1 signifying that the Drive Enclosure Environmental Monitoring Unit is the  
affected element.  
3454  
3455  
88030d7e  
88030d7f  
3
3
d
d
7e  
7f  
Storage Cell: %1 Event Code: %2 Description: Invalid data was read from a  
Drive Enclosure Environmental Monitoring Unit NVRAM. This problem was  
detected by the Drive Enclosure Environmental Monitoring Unit located in the  
drive enclosure identified in the dencl_num field within the rack identified in the  
rack_num field. The rack_num field will not be valid until a future release. The  
alarm_error_code.field.en field contains the value 1 signifying that the Drive  
Enclosure Environmental Monitoring Unit is the affected element.  
Storage Cell: %1 Event Code: %2 Description: An internal Drive Enclosure  
Environmental Monitoring Unit error has occurred. This problem was detected by  
the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure  
identified in the dencl_num field within the rack identified in the rack_num field.  
The rack_num field will not be valid until a future release. The  
alarm_error_code.field.en field contains the value 1 signifying that the Drive  
Enclosure Environmental Monitoring Unit is the affected element. The cause of  
the improper operation is described by the content of the  
alarm_error_code.field.ec field as follows: 11 = The Drive Enclosure  
Environmental Monitoring Unit cannot write data to the NVRAM. 12 = The Drive  
Enclosure Environmental Monitoring Unit cannot read data from the NVRAM. 13  
= The Field Programmable Gate Array (FPGA) that controls the ESI bus failed to  
load information required for Drive Enclosure Environmental Monitoring Unit  
operation.  
3458  
88030d82  
3
d
82  
Storage Cell: %1 Event Code: %2 Description: A drive enclosure’s address is  
incorrect or the enclosure has no address. This problem was detected by the  
Drive Enclosure Environmental Monitoring Unit located in the drive enclosure  
identified in the dencl_num field within the rack identified in the rack_num field.  
The rack_num field will not be valid until a future release. The  
alarm_error_code.field.en field contains the value 1 signifying that the Drive  
Enclosure Environmental Monitoring Unit is the affected element.  
Storage Management Appliance Software Event Code Definitions Application Notes  
49  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
3459  
3461  
3469  
88030d83  
88030d85  
88030d8d  
6
d
83  
85  
8d  
Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental  
Monitoring Unit has experienced a hardware failure. This problem was detected  
by the Drive Enclosure Environmental Monitoring Unit located in the drive  
enclosure identified in the dencl_num field within the rack identified in the  
rack_num field. The rack_num field will not be valid until a future release. The  
alarm_error_code.field.en field contains the value 1 signifying that the Drive  
Enclosure Environmental Monitoring Unit is the affected element.  
3
6
d
d
Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply  
failed to respond to a shut down command. This problem was detected by the  
Drive Enclosure Environmental Monitoring Unit located in the drive enclosure  
identified in the dencl_num field within the rack identified in the rack_num field.  
The rack_num field will not be valid until a future release. The  
alarm_error_code.field.en field contains the value 1 signifying that the Drive  
Enclosure Environmental Monitoring Unit is the affected element.  
Storage Cell: %1 Event Code: %2 Description: A drive enclosure transceiver  
error has been detected. This problem was detected by the Drive Enclosure  
Environmental Monitoring Unit located in the drive enclosure identified in the  
dencl_num field within the rack identified in the rack_num field. The rack_num  
field will not be valid until a future release. The location of the transceiver (1  
through 4) is identified in the alarm_error_code.field.en field as follows: 1 =  
Transceiver 01 2 = Transceiver 02 3 = Transceiver 03 4 = Transceiver 04 The  
transceiver error condition is described by the content of the  
alarm_error_code.field.ec field as follows: 1 = The transceivers on this link are  
not the same type or they are incompatible with the drive enclosure I/O module.  
This error prevents the controller from establishing a link with the enclosure drives  
and eliminates the enclosure dual-loop capability. 2 = The transceiver can no  
longer detect a data signal. This error prevents the controller from transferring  
data on a loop and eliminates the enclosure dual-loop capability. 3 = The  
system has detected an FC-AL bus fault involving a transceiver. This error prevents  
the controller from transferring data on a loop and eliminates the enclosure  
dual-loop capability.  
3489  
88030da1  
6
d
a1  
Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply  
voltage sensor out of range condition has been reported. This problem was  
detected by the Drive Enclosure Environmental Monitoring Unit located in the  
drive enclosure identified in the dencl_num field within the rack identified in the  
rack_num field. The rack_num field will not be valid until a future release. The  
location of the voltage sensor (1 through 4) is identified in the  
alarm_error_code.field.en field as follows: 1 = Power Supply 1 +5 VDC 2 =  
Power Supply 1 +12 VDC 3 = Power Supply 2 +5 VDC 4 = Power Supply 2 +12  
VDC The voltage sensor out of range condition is described by the content of the  
alarm_error_code.field.ec field as follows: 1 = The element voltage is  
approaching, but has not reached, the high voltage CRITICAL threshold.  
Continued operation under these conditions may result in a CRITICAL condition.  
2 = The element voltage is above the high voltage CRITICAL threshold. 3 = The  
element voltage is approaching, but h as not reached, the low voltage CRITICAL  
threshold. Continued operation under these conditions may result in a CRITICAL  
condition. 4 = The element voltage has reached the low voltage CRITICAL  
threshold.  
50  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
3509  
88030db5  
6
d
b5  
Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply  
current sensor out of range condition has been reported. This problem was  
detected by the Drive Enclosure Environmental Monitoring Unit located in the  
drive enclosure identified in the dencl_num field within the rack identified in the  
rack_num field. The rack_num field will not be valid until a future release. The  
location of the current sensor (1 through 4) is identified in the  
alarm_error_code.field.en field as follows: 1 = Power Supply 1 +5 VDC 2 =  
Power Supply 1 +12 VDC 3 = Power Supply 2 +5 VDC 4 = Power Supply 2 +12  
VDC The current sensor out of range condition is described by the content of the  
alarm_error_code.field.ec field as follows: 1 = The element current is  
approaching, but has not reached, the high current CRITICAL threshold.  
Continued operation under these conditions may result in a CRITICAL condition.  
2 = The element current is above the high current CRITICAL threshold.  
3544  
3545  
88030dd8  
88030dd9  
3
6
d
d
d8  
d9  
Storage Cell: %1 Event Code: %2 Description: A drive enclosure backplane  
invalid NVRAM read error has occurred. This problem was detected by the Drive  
Enclosure Environmental Monitoring Unit located in the drive enclosure identified  
in the dencl_num field within the rack identified in the rack_num field. The  
rack_num field will not be valid until a future release. The  
alarm_error_code.field.en field contains the value 1 signifying that the drive  
enclosure is the affected element.  
Storage Cell: %1 Event Code: %2 Description: A drive enclosure backplane  
error has occurred. This problem was detected by the Drive Enclosure  
Environmental Monitoring Unit located in the drive enclosure identified in the  
dencl_num field within the rack identified in the rack_num field. The rack_num  
field will not be valid until a future release. The alarm_error_code.field.en field  
contains the value 1 signifying that the drive enclosure is the affected element.  
The cause of the improper operation is described by the content of the  
alarm_error_code.field.ec field as follows: 11 = Unable to write data to the  
NVRAM. This problem prevents communication between elements in the  
enclosure. 12 = Unable to read data from the NVRAM. This problem prevents  
communication between elements in the enclosure. 13 = NVRAM has not been  
initialized properly. This is a manufacturing error.  
3549  
88030ddd  
6
d
dd  
Storage Cell: %1 Event Code: %2 Description: A drive enclosure I/O module  
error has occurred. This problem was detected by the Drive Enclosure  
Environmental Monitoring Unit located in the drive enclosure identified in the  
dencl_num field within the rack identified in the rack_num field. The rack_num  
field will not be valid until a future release. The location of the I/O module (A  
(01) and B (02)) is identified in the alarm_error_code.field.en field. The cause of  
the improper operation is described by the content of the  
alarm_error_code.field.ec field as follows: 1 = The I/O module’s Fibre Channel  
link speed is not supported by the backplane. This error prevents the controller  
from establishing a link with enclosure drives and eliminates the enclosure  
dual-loop capability. 11 = Unable to write data to the I/O module NVRAM. 12  
= Unable to read data from the I/O module NVRAM.  
3550  
88030dde  
3
d
de  
Storage Cell: %1 Event Code: %2 Description: A drive enclosure I/O module is  
unable to communicate with the Drive Enclosure Environmental Monitoring Unit.  
This problem was detected by the Drive Enclosure Environmental Monitoring Unit  
located in the drive enclosure identified in the dencl_num field within the rack  
identified in the rack_num field. The rack_num field will not be valid until a future  
release. The location of the I/O module (A (01) and B (02)) is identified in the  
alarm_error_code.field.en field.  
Storage Management Appliance Software Event Code Definitions Application Notes  
51  
HSV Element Manager Event Codes  
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)  
Event  
ID  
Event  
Code  
Sev- SWC  
Evt.  
No.  
erity  
ID  
Description  
3564  
88030dec  
3
d
ec  
Storage Cell: %1 Event Code: %2 Description: A drive enclosure I/O module  
invalid NVRAM read error has occurred. This problem was detected by the Drive  
Enclosure Environmental Monitoring Unit located in the drive enclosure identified  
in the dencl_num field within the rack identified in the rack_num field. The  
rack_num field will not be valid until a future release. The location of the I/O  
module (A (01) or B (02)) is identified in the alarm_error_code.field.en field.  
3568  
88030df0  
2
d
f0  
Storage Cell: %1 Event Code: %2 Description: The status has changed on one or  
more of the drive enclosures. This is an informational event triggered by the  
occurrence of a change in the status of a drive enclosure. The content of the  
alarm_error_code field, drive enclosure, and rack number have no meaning for  
this event.  
16896 88034200  
16897 88034201  
16899 88034203  
2
2
2
42  
42  
42  
0
1
3
Storage Cell: %1 Event Code: %2 Description: Indicated Host Fibre Channel  
port transitioned to link down.  
Storage Cell: %1 Event Code: %2 Description: Indicated Host Fibre Channel  
port transitioned to link failed.  
Storage Cell: %1 Event Code: %2 Description: An excessive number of link  
errors were detected on a Fibre Channel port. The error counters are checked  
every hour. This is an informational event that reports all link status errors  
detected by the Tachyon chip, triggered by an excessive number detected in one  
category.  
16900 88034204  
3
6
42  
83  
4
0
Storage Cell: %1 Event Code: %2 Description: A Fibre Channel port on the  
HSV110 controller has failed to respond. The evt_peq.peb field contains port  
event information. The evt_peq.peq_frz_prod_index field contains the index to  
the port event block that points to when the Tachyon chip entered the frozen state.  
The evt_peq.peq_prod_index field contains the index to the next port event block.  
The evt_peq.peq_cons_index field contains the index to the next port event block  
to be acted upon.  
33536  
88038300  
Storage Cell: %1 Event Code: %2 Description: A failure was detected during the  
execution of this HSV110 controller’s on board diagnostics.  
52  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Management Agent Events  
Table 9 shows events generated by the HSV Management Agent, which are logged in the  
Storage Management Appliance Event Log. The Event Number (Evt. No.) codes can be used  
to correlate events recorded in the Management Agent Event Log of the HSV Element  
Manager with the events logged in the Storage Management Appliance Event Log.  
Table 9: HSV Element Manager Event Codes: Management Agent Events  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
20000 88034e20  
3
0
Storage Cell: %1 Unhandled Management event generated. Event Code: %2  
Description: %3  
20001 88034e21  
20002 88034e22  
20003 88034e23  
20004 88034e24  
2
2
2
6
1
2
3
4
Storage Cell: %1 SCMI Object Already Exists Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Supplied Buffer Too Small Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Object Already Assigned Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Insufficient Available Data Storage Event Code: %2  
Description: %3  
20005 88034e25  
20006 88034e26  
3
2
5
6
Storage Cell: %1 SCMI Internal Error Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Invalid Cell Status for Logical Disk Event Code: %2 Description:  
%3  
20007 88034e27  
20008 88034e28  
20009 88034e29  
2
2
2
7
8
9
Storage Cell: %1 SCMI Invalid Class Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Invalid Function Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Invalid Logical Disk Block State Event Code: %2 Description:  
%3  
20010 88034e2a  
20011 88034e2b  
20012 88034e2c  
20013 88034e2d  
20014 88034e2e  
20015 88034e2f  
20016 88034e30  
20017 88034e31  
20018 88034e32  
20019 88034e33  
20020 88034e34  
20021 88034e35  
20022 88034e36  
20023 88034e37  
20024 88034e38  
20025 88034e39  
20026 88034e3a  
2
2
2
2
2
2
2
2
3
3
2
2
2
2
2
2
2
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
Storage Cell: %1 SCMI Invalid Loop Configuration Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Invalid Parameter Event Code: %2 Description: %3  
Storage Cell: %1 SCmi Invalid Parameter handle Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Invalid Parameter Id Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Invalid Quorum Configuration Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Invalid Target Handle Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Invalid Target Id Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Invalid Time Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Media is Inaccessible Event Code: %2 Description: %3  
Storage Cell: %1 SCMI No Fibre Channel Port Event Code: %2 Description: %3  
Storage Cell: %1 SCMI No Image Event Code: %2 Description: %3  
Storage Cell: %1 SCMI No Permission Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Storage system not initialized Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Not a Loop Port Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Not a Participating Controller Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Object is in Use Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Parameter Object Does Not Exist Event Code: %2 Description:  
%3  
20027 88034e3b  
20028 88034e3c  
20029 88034e3d  
20030 88034e3e  
2
2
2
2
27  
28  
29  
30  
Storage Cell: %1 SCMI Target Object Does Not Exist Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Timeout Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Unknown Id Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Unknown Parameter Handle Event Code: %2 Description: %3  
Storage Management Appliance Software Event Code Definitions Application Notes  
53  
 
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
20031 88034e3f  
20032 88034e40  
20033 88034e41  
20034 88034e42  
20035 88034e43  
20036 88034e44  
20037 88034e45  
20038 88034e46  
20039 88034e47  
20040 88034e48  
20041 88034e49  
2
2
3
3
2
2
2
2
2
2
2
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
Storage Cell: %1 SCMI Unrecoverable Media Error Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Invalid State Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Transport Error Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Volume is Missing Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Invalid Cursor Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Invalid Target Logical Disk Event Code: %2 Description: %3  
Storage Cell: %1 SCMI No More Events Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Lock Busy Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Time Not Set Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Not a Supported Version Event Code: %2 Description: %3  
Storage Cell: %1 SCMI No Logical Disk for StorageCell Virtual Disk Event Code: %2  
Description: %3  
20042 88034e4a  
20043 88034e4b  
20044 88034e4c  
20045 88034e4d  
20046 88034e4e  
20047 88034e4f  
20048 88034e50  
2
3
2
2
2
2
2
42  
43  
44  
45  
46  
47  
48  
Storage Cell: %1 SCMI Logical disk Presented Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Operation Denied On Slave Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Not DRM Licensed Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Not DRM Member Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Invalid DRM Mode Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Invalid DRM State Event Code: %2 Description: %3  
Storage Cell: %1 Security credentials needed. Please update your system’s ID and  
password in the Storage System Access menu. Event Code: %2 Description: %3  
20049 88034e51  
2
49  
Storage Cell: %1 Security credentials supplied were invalid. Please update your system’s  
ID and password in the Storage System Access menu. Event Code: %2 Description: %3  
20050 88034e52  
20051 88034e53  
20052 88034e54  
20053 88034e55  
20054 88034e56  
20055 88034e57  
20056 88034e58  
2
3
2
2
2
2
2
50  
51  
52  
53  
54  
55  
56  
Storage Cell: %1 SCMI Already Logged In Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Cell Connection Down Event Code: %2 Description: %3  
Storage Cell: %1 SCMI DRM Group Empty Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Incompatible Attribute Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Is Drm Member Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Is Log Unit Event Code: %2 Description: %3  
Storage Cell: %1 SCMI No Destination DRM Group Specified Event Code: %2  
Description: %3  
20057 88034e59  
20058 88034e5a  
20059 88034e5b  
20060 88034e5c  
20061 88034e5d  
20062 88034e5e  
20063 88034e5f  
20064 88034e60  
20065 88034e61  
20066 88034e62  
20067 88034e63  
2
3
2
2
2
2
2
2
2
2
2
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
Storage Cell: %1 SCMI Not Presented Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Other Nsc Failed Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Max Objects Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Max Size Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Password Mismatch Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Is Merging Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Is Logging Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Is Suspended Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Bad Image Header Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Bad Image Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Image Too Large Event Code: %2 Description: %3  
54  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
20068 88034e64  
20069 88034e65  
20070 88034e66  
20071 88034e67  
20072 88034e68  
20073 88034e69  
2
2
2
2
2
2
2
2
2
6
2
2
68  
69  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
Storage Cell: %1 SCMI EMU Not Available Event Code: %2 Description: %3  
Storage Cell: %1 SCMI EMU Indefinite Delay Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Image Incompatible Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Bad Image Segment Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Image Already Loaded Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Image Write Error Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Logical Disk Sharing Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Bad Image Size Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Image Load Busy Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Volume Failure Predicted Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Invalid Object Condition Event Code: %2 Description: %3  
20074  
20075  
20076  
88034e6a  
88034e6b  
88034e6c  
20077 88034e6d  
20078 88034e6e  
20079 88034e6f  
Storage Cell: %1 SCMI Invalid Predecessor Virtual Disk Condition Event Code: %2  
Description: %3  
20080 88034e70  
20081 88034e71  
2
2
80  
81  
Storage Cell: %1 SCMI Invalid Volume Usage Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Minimum Volumes In Disk Group Event Code: %2 Description:  
%3  
20082 88034e72  
20083 88034e73  
20084 88034e74  
20085 88034e75  
20086 88034e76  
20087 88034e77  
2
2
2
2
2
3
82  
83  
84  
85  
86  
87  
Storage Cell: %1 SCMI Shutdown In Progress Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Not Ready Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Is Snapshot Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Incompatible Mirror Policy Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Inoperative Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Disk group inoperative or less than 8 disks in group Event  
Code: %2 Description: %3  
20088 88034e78  
20089 88034e79  
20090 88034e7a  
20091 88034e7b  
6
2
3
2
88  
89  
90  
91  
Storage Cell: %1 SCMI StorageCell Inoperative Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Failsafe Locked Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Data Flush Incomplete Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Redundancy Mirrored Inoperative Event Code: %2 Description:  
%3  
20092 88034e7c  
20093 88034e7d  
20094 88034e7e  
20095 88034e7f  
20096 88034e80  
20097 88034e81  
20098 88034e82  
20099 88034e83  
20100 88034e84  
2
3
2
2
6
6
2
2
2
92  
93  
94  
Storage Cell: %1 SCMI Duplicate LUN Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Other Remote NSC Failed Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Unknown Remote Unit Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Unknown Remote DRM Group Event Code: %2 Description: %3  
Storage Cell: %1 SCMI PLDMC Failed Event Code: %2 Description: %3  
Storage Cell: %1 SCMI Lock Failed Event Code: %2 Description: %3  
95  
96  
97  
98  
99  
100  
Storage Cell: %1 SCMI Remote SCS Error Event Code: %2 Description: %3  
Storage Cell: %1 Scmi Cell Connection Up Event Code: %2 Description: %3  
Storage Cell: %1 Scmi Login Needed - Password Changed Event Code: %2  
Description: %3  
20101 88034e85  
20102 88034e86  
20103 88034e87  
2
2
2
101  
102  
103  
Storage Cell: %1 Scmi Max Logins Reached Event Code: %2 Description: %3  
Storage Cell: %1 Scmi Invalid Cookie Event Code: %2 Description: %3  
Storage Cell: %1 Scmi Login Timed Out Event Code: %2 Description: %3  
Storage Management Appliance Software Event Code Definitions Application Notes  
55  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
20104 88034e88  
20105 88034e89  
20106 88034e8a  
20107 88034e8b  
20108 88034e8c  
20109 88034e8d  
20110 88034e8e  
20111 88034e8f  
20112 88034e90  
20113 88034e91  
20114 88034e92  
20115 88034e93  
20116 88034e94  
21000 88035208  
21001 88035209  
21002 8803520a  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
6
3
104  
105  
106  
107  
Storage Cell: %1 Scmi Max Snapshot Depth Reached Event Code: %2 Description: %3  
Storage Cell: %1 Scmi Attribute Mismatch Event Code: %2 Description: %3  
Storage Cell: %1 Scmi Password Not Set Event Code: %2 Description: %3  
Storage Cell: %1 Scmi Not Host Port Event Code: %2 Description: %3  
Storage Cell: %1 Scmi Duplicate Lun WWID Event Code: %2 Description: %3  
Storage Cell: %1 Scmi System Inoperative Event Code: %2 Description: %3  
Storage Cell: %1 Scmi SnapClone Active Event Code: %2 Description: %3  
Storage Cell: %1 Scmi Emu Load Busy Event Code: %2 Description: %3  
Storage Cell: %1 Scmi Duplicate User Name Event Code: %2 Description: %3  
Storage Cell: %1 Scmi Drive Reserved For Code Load Event Code: %2 Description: %3  
Storage Cell: %1 Scmi Already Presented Event Code: %2 Description: %3  
Storage Cell: %1 Scmi Invalid Remote Scell Event Code: %2 Description: %3  
Storage Cell: %1 Scmi No Scmi Lock Event Code: %2 Description: %3  
Storage Cell: %1 Logical Disk Condition Change Event Code: %2 Description: %3  
Storage Cell: %1 Storage system is FULL **critical** Event Code: %2 Description: %3  
108  
109  
110  
111  
112  
113  
114  
115  
116  
1000  
1001  
1002  
Storage Cell: %1 Storage system is almost FULL. Disk group at or above maximum  
capacity warning level. Event Code: %2 Description: %3  
21003 8803520b  
2
1003  
Storage Cell: %1 NSC Cache Battery Condition Change Event Code: %2 Description:  
%3  
21004 8803520c  
21005 8803520d  
21006 8803520e  
21007 8803520f  
21008 88035210  
21009 88035211  
21010 88035212  
21011 88035213  
21012 88035214  
2
2
2
2
2
2
2
2
2
1004  
1005  
1006  
1007  
1008  
1009  
1010  
1011  
1012  
Storage Cell: %1 NSC Cache Condition Change Event Code: %2 Description: %3  
Storage Cell: %1 NSC Condition Change Event Code: %2 Description: %3  
Storage Cell: %1 NSC FC Port Condition Change Event Code: %2 Description: %3  
Storage Cell: %1 Physical Device Condition Change Event Code: %2 Description: %3  
Storage Cell: %1 Physical Store Condition Change Event Code: %2 Description: %3  
Storage Cell: %1 Host condition change Event Code: %2 Description: %3  
Storage Cell: %1 Storage system time has been set Event Code: %2 Description: %3  
Storage Cell: %1 Volume Condition change Event Code: %2 Description: %3  
Storage Cell: %1 Volume insufficient_resources condition change Event Code: %2  
Description: %3  
21013 88035215  
21014 88035216  
2
2
1013  
1014  
Storage Cell: %1 Volume Quorum Disk change Event Code: %2 Description: %3  
Storage Cell: %1 The state of an object in the system has changed. View adjacent events  
for more detail. Event Code: %2 Description: %3  
22001 880355f1  
22002 880355f2  
6
2
2001  
2002  
Storage Cell: %1 Startup Failed Event Code: %2 Description: %3  
Storage Cell: %1 Management agent event log cleared successfully Event Code: %2  
Description: %3  
22003 880355f3  
3
2003  
Storage Cell: %1 Invalid name specified for storage system Event Code: %2  
Description: %3  
22004 880355f4  
22005 880355f5  
2
3
2004  
2005  
Storage Cell: %1 Storage system is not initialized Event Code: %2 Description: %3  
Storage Cell: %1 Duplicate name for virtual disk found Event Code: %2 Description:  
%3  
22006 880355f6  
3
2006  
Storage Cell: %1 Invalid name specified for virtual disk Event Code: %2 Description:  
%3  
56  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
22007 880355f7  
3
2007  
Storage Cell: %1 Virtual disk name exceeds maximum length Event Code: %2  
Description: %3  
22008 880355f8  
3
2008  
Storage Cell: %1 Invalid parameter specified for virtual disk Event Code: %2  
Description: %3  
22009 880355f9  
22010 880355fa  
3
3
2009  
2010  
Storage Cell: %1 No virtual disk found Event Code: %2 Description: %3  
Storage Cell: %1 Specified virtual disk size exceeds available size Event Code: %2  
Description: %3  
22011 880355fb  
22012 880355fc  
22013 880355fd  
22014 880355fe  
22015 880355ff  
22016 88035600  
22017 88035601  
22018 88035602  
22019 88035603  
22020 88035604  
22021 88035605  
22022 88035606  
2
3
3
3
3
3
3
3
3
3
3
3
2011  
2012  
2013  
2014  
2015  
2016  
2017  
2018  
2019  
2020  
2021  
2022  
Storage Cell: %1 There are not enough disk drives to create a disk group Event Code:  
%2 Description: %3  
Storage Cell: %1 Specified number of device exceeds available number of disk Event  
Code: %2 Description: %3  
Storage Cell: %1 Specified number of device is below the minimum number of disk to  
create a disk group (minimum 8) Event Code: %2 Description: %3  
Storage Cell: %1 No available volumes to complete the request Event Code: %2  
Description: %3  
Storage Cell: %1 Specified spare count exceeds maximum count Event Code: %2  
Description: %3  
Storage Cell: %1 Completed unpresenting virutal disk to host Event Code: %2  
Description: %3  
Storage Cell: %1 Negative value for device count is invalid Event Code: %2  
Description: %3  
Storage Cell: %1 Specified spare count is below minimum count Event Code: %2  
Description: %3  
Storage Cell: %1 Specified device count is below minimum count Event Code: %2  
Description: %3  
Storage Cell: %1 Requested device count exceeds available physical store Event Code:  
%2 Description: %3  
Storage Cell: %1 Invalid refresh interval value. Should be numeric and non-negative.  
Event Code: %2 Description: %3  
Storage Cell: %1 Invalid security message. Should not be blank. Event Code: %2  
Description: %3  
22023 88035607  
22024 88035608  
22025 88035609  
2
2
2
2023  
2024  
2025  
Storage Cell: %1 Virtual Disk Create Complete Event Code: %2 Description: %3  
Storage Cell: %1 Storage system uninitialized Event Code: %2 Description: %3  
Storage Cell: %1 Storage system successfully initialized Event Code: %2 Description:  
%3  
22026 8803560a  
22027 8803560b  
22028 8803560c  
22029 8803560d  
22030 8803560e  
22031 8803560f  
22032 88035610  
2
2
2
2
2
2
2
2026  
2027  
2028  
2029  
2030  
2031  
2032  
Storage Cell: %1 Device Added Successfully Event Code: %2 Description: %3  
Storage Cell: %1 Storage system successfully renamed Event Code: %2 Description: %3  
Storage Cell: %1 Virtual Disk Delete Complete Event Code: %2 Description: %3  
Storage Cell: %1 Virtual Disk Renamed - Complete Event Code: %2 Description: %3  
Storage Cell: %1 Refresh Interval Changed Event Code: %2 Description: %3  
Storage Cell: %1 Security Message Changed Event Code: %2 Description: %3  
Storage Cell: %1 Present Virtual Disk to a Host - Complete Event Code: %2  
Description: %3  
22033 88035611  
2
2033  
Storage Cell: %1 Control Startup Complete Event Code: %2 Description: %3  
Storage Management Appliance Software Event Code Definitions Application Notes  
57  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
22034 88035612  
22035 88035613  
22036 88035614  
22037 88035615  
22038 88035616  
22039 88035617  
2
2
2
2
6
2
2034  
2035  
2036  
2037  
2038  
2039  
Storage Cell: %1 Change Device Usage Complete Event Code: %2 Description: %3  
Storage Cell: %1 Control Shutdown - Complete Event Code: %2 Description: %3  
Storage Cell: %1 Nsc Shutdown - Complete Event Code: %2 Description: %3  
Storage Cell: %1 Nsc Crash - Complete Event Code: %2 Description: %3  
Storage Cell: %1 Control Memory Allocation Failure Event Code: %2 Description: %3  
Storage Cell: %1 There must be at least 5 member devices to create Raid 5 VD Event  
Code: %2 Description: %3  
22040 88035618  
2
2040  
Storage Cell: %1 Access level denied or session activity timeout. Please log in again.  
Event Code: %2 Description: %3  
22041 88035619  
22042 8803561a  
22043 8803561b  
22044 8803561c  
22045 8803561d  
22046 8803561e  
22047 8803561f  
22048 88035620  
22049 88035621  
22050 88035622  
2
2
2
2
2
6
2
2
2
2
2041  
2042  
2043  
2044  
2045  
2046  
2047  
2048  
2049  
2050  
Storage Cell: %1 Virtual Disk Snapshot - Completed Event Code: %2 Description: %3  
Storage Cell: %1 Virtual Disk Snapclone - Completed Event Code: %2 Description: %3  
Storage Cell: %1 Virtual Disk Snapshot - Failed Event Code: %2 Description: %3  
Storage Cell: %1 Virtual Disk Snapclone - Failed Event Code: %2 Description: %3  
Storage Cell: %1 Restore Device - Completed Event Code: %2 Description: %3  
Storage Cell: %1 Device Failed Event Code: %2 Description: %3  
Storage Cell: %1 Host record added successfully Event Code: %2 Description: %3  
Storage Cell: %1 Nsa object discarded successfully Event Code: %2 Description: %3  
Storage Cell: %1 Invalid host adapter ID Event Code: %2 Description: %3  
Storage Cell: %1 Specified device is already a member of the system Event Code: %2  
Description: %3  
22051 88035623  
22052 88035624  
2
2
2051  
2052  
Storage Cell: %1 Create Folder - Completed Event Code: %2 Description: %3  
Storage Cell: %1 Change Object Properties - Completed Event Code: %2 Description:  
%3  
22053 88035625  
22057 88035629  
22058 8803562a  
22059 8803562b  
22060 8803562c  
22061 8803562d  
2
2
2
2
2
2
2053  
2057  
2058  
2059  
2060  
2061  
Storage Cell: %1 Comments exceed maximum size Event Code: %2 Description: %3  
Storage Cell: %1 Completed disk group creation Event Code: %2 Description: %3  
Storage Cell: %1 Added host port Event Code: %2 Description: %3  
Storage Cell: %1 Discarded host port Event Code: %2 Description: %3  
Storage Cell: %1 EMU/Shelf code load complete Event Code: %2 Description: %3  
Storage Cell: %1 Operation will exceed the available capacity of the disk group Event  
Code: %2 Description: %3  
22062 8803562e  
22063 8803562f  
2
2
2062  
2063  
Storage Cell: %1 Controller(s) code load complete Event Code: %2 Description: %3  
Storage Cell: %1 The target device is not in the right condition to perform the operation  
Event Code: %2 Description: %3  
22064 88035630  
22065 88035631  
2
2
2064  
2065  
Storage Cell: %1 Storage system Device Addition Policy changed successfully Event  
Code: %2 Description: %3  
Storage Cell: %1 Maximum number of disk groups exceeded Event Code: %2  
Description: %3  
22066 88035632  
22067 88035633  
3
3
2066  
2067  
Storage Cell: %1 Nsa object discard failed. Event Code: %2 Description: %3  
Storage Cell: %1 There are not enough disks to meet the minimum number requirement  
Event Code: %2 Description: %3  
22068 88035634  
2
2068  
Storage Cell: %1 Entry added successfully in the password file Event Code: %2  
Description: %3  
58  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
22069 88035635  
22070 88035636  
22071 88035637  
2
2
2
2
2
2
2
2
2
2069  
2070  
2071  
2072  
2073  
2074  
2075  
2076  
2077  
Storage Cell: %1 Entry updated successfully in the password file Event Code: %2  
Description: %3  
Storage Cell: %1 Entry discarded successfully in the password file Event Code: %2  
Description: %3  
Storage Cell: %1 Storage system is in an unknown state. Communications error or  
unresponsive controller. Event Code: %2 Description: %3  
22072  
22073  
22074  
22075  
22076  
88035638  
88035639  
8803563a  
8803563b  
8803563c  
Storage Cell: %1 Object not found. Operation on this object is completed Event Code:  
%2 Description: %3  
Storage Cell: %1 There is no more available space to create a virtual disk Event Code:  
%2 Description: %3  
Storage Cell: %1 Name or comments contains invalid characters Event Code: %2  
Description: %3  
Storage Cell: %1 Duplicate - Another object with the same name is found Event Code:  
%2 Description: %3  
Storage Cell: %1 Error - No healthy disk group(s) to create a unit. Resolve any abnormal  
conditions in the disk group first. Event Code: %2 Description: %3  
22077 8803563d  
Storage Cell: %1 Error - Operating System ID must be a valid number. Event Code: %2  
Description: %3  
22078  
22079  
8803563e  
8803563f  
2
2
3
2
2078  
2079  
2080  
2081  
Storage Cell: %1 Watchdog successfully started Event Code: %2 Description: %3  
Storage Cell: %1 Watchdog successfully stopped Event Code: %2 Description: %3  
Storage Cell: %1 Delete Event Config List failed Event Code: %2 Description: %3  
22080 88035640  
22081 88035641  
Storage Cell: %1 Disk group meltdown repaired successfully. Event Code: %2  
Description: %3  
22082 88035642  
22083 88035643  
22084 88035644  
22085 88035645  
22086 88035646  
22087 88035647  
22088 88035648  
22089 88035649  
22090 8803564a  
22091 8803564b  
2
2
2
2
2
2
2
2
2
2
2082  
2083  
2084  
2085  
2086  
2087  
2088  
2089  
2090  
2091  
Storage Cell: %1 There are no available LUNs to present this unit. Event Code: %2  
Description: %3  
Storage Cell: %1 Controller time synchronization turned on. Event Code: %2  
Description: %3  
Storage Cell: %1 Controller time synchronization turned off. Event Code: %2  
Description: %3  
Storage Cell: %1 System login failed. Invalid password. Event Code: %2 Description:  
%3  
Storage Cell: %1 System is not set for password validation. Event Code: %2  
Description: %3  
Storage Cell: %1 Agent is already logged in to this system. Event Code: %2  
Description: %3  
Storage Cell: %1 StorageCell time set to custom time. Controller time syncronization  
automatically turned off. Event Code: %2 Description: %3  
Storage Cell: %1 StorageCell time set to SAN appliance time. Event Code: %2  
Description: %3  
Storage Cell: %1 StorageCell time set to browser time. Controller time syncronization  
automatically turned off. Event Code: %2 Description: %3  
Storage Cell: %1 StorageCell time set to controller time. Controller time syncronization  
automatically turned off. Event Code: %2 Description: %3  
23001 880359d9  
23002 880359da  
2
2
3001  
3002  
Storage Cell: %1 Event Manager Offline Event Code: %2 Description: %3  
Storage Cell: %1 Event Manager Online Event Code: %2 Description: %3  
Storage Management Appliance Software Event Code Definitions Application Notes  
59  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
23003 880359db  
23004 880359dc  
23005 880359dd  
23006 880359de  
23007 880359df  
6
2
3
3
2
3003  
3004  
3005  
3006  
3007  
Storage Cell: %1 Event Manager - Startup Failed Event Code: %2 Description: %3  
Storage Cell: %1 Event Manager - Startup Complete Event Code: %2 Description: %3  
Storage Cell: %1 Event Manager - Abnormal Startup Event Code: %2 Description: %3  
Storage Cell: %1 Event Manager - Shutdown Failed Event Code: %2 Description: %3  
Storage Cell: %1 Event Manager - Shutdown Complete Event Code: %2 Description:  
%3  
23008 880359e0  
23009 880359e1  
3
3
3008  
3009  
Storage Cell: %1 Event Manager - Abnormal Shutdown Event Code: %2 Description:  
%3  
Storage Cell: %1 Unable to open NSA Local Event Log File Event Code: %2  
Description: %3  
23010 880359e2  
23011 880359e3  
3
3
3010  
3011  
Storage Cell: %1 Unable to open NSA Debug File Event Code: %2 Description: %3  
Storage Cell: %1 EM: Agent event file on SC MLD unavailable - trying local event file.  
Event Code: %2 Description: %3  
23012 880359e4  
23013 880359e5  
3
3
3012  
3013  
Storage Cell: %1 Unable to open Local Temp Event File - possibly no initialized SC  
Event Code: %2 Description: %3  
Storage Cell: %1 Unable to clear NSA Local Event Log File Event Code: %2  
Description: %3  
23014 880359e6  
23015 880359e7  
23016 880359e8  
23017 880359e9  
23018 880359ea  
23019 880359eb  
23020 880359ec  
23021 880359ed  
23022 880359ee  
23023 880359ef  
23024 880359f0  
23025 880359f1  
23026 880359f2  
23027 880359f3  
23028 880359f4  
23029 880359f5  
23030 880359f6  
3
3
3
3
6
2
2
2
2
2
2
2
2
2
3
2
2
3014  
3015  
3016  
3017  
3018  
3019  
3020  
3021  
3022  
3023  
3024  
3025  
3026  
3027  
3028  
3029  
3030  
Storage Cell: %1 Unable to clear NSA Debug File Event Code: %2 Description: %3  
Storage Cell: %1 Unable to clear NSA Event Log File Event Code: %2 Description: %3  
Storage Cell: %1 Local log file found on startup Event Code: %2 Description: %3  
Storage Cell: %1 Event Queue Flush Error Event Code: %2 Description: %3  
Storage Cell: %1 Log Event Action Failed Event Code: %2 Description: %3  
Storage Cell: %1 EM File Manager Online Event Code: %2 Description: %3  
Storage Cell: %1 EM File Manager Offline Event Code: %2 Description: %3  
Storage Cell: %1 EM Log Manager Online Event Code: %2 Description: %3  
Storage Cell: %1 EM Log Manager Offline Event Code: %2 Description: %3  
Storage Cell: %1 Startup Complete Event Code: %2 Description: %3  
Storage Cell: %1 Local NSA logfile is empty Event Code: %2 Description: %3  
Storage Cell: %1 Event Queue Online Event Code: %2 Description: %3  
Storage Cell: %1 Event Queue Offline Event Code: %2 Description: %3  
Storage Cell: %1 Event Queue is full Event Code: %2 Description: %3  
Storage Cell: %1 Status Descriptions Unavailable Event Code: %2 Description: %3  
Storage Cell: %1 EM Description Mngr Online Event Code: %2 Description: %3  
Storage Cell: %1 EM: User Defined Status Description File Initialized Event Code: %2  
Description: %3  
23031 880359f7  
23032 880359f8  
23033 880359f9  
23034 880359fa  
23035 880359fb  
23036 880359fc  
3
3
3
3
3
6
3031  
3032  
3033  
3034  
3035  
3036  
Storage Cell: %1 EM Description Mngr Start Failed Event Code: %2 Description: %3  
Storage Cell: %1 EM Log Mngr Start Failed Event Code: %2 Description: %3  
Storage Cell: %1 EM File Mngr Start Failed Event Code: %2 Description: %3  
Storage Cell: %1 EM Event Queue Start Failed Event Code: %2 Description: %3  
Storage Cell: %1 EM: NSA log file unavailable Event Code: %2 Description: %3  
Storage Cell: %1 EM Memory Allocation Error Event Code: %2 Description: %3  
60  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
23037 880359fd  
23038 880359fe  
23039 880359ff  
23040 88035a00  
3
3
3
2
3037  
3038  
3039  
3040  
Storage Cell: %1 EM: Local Event Configuration File Unavailable Event Code: %2  
Description: %3  
Storage Cell: %1 EM: MLD Notification File Unavailable - retrieving local backup copy  
Event Code: %2 Description: %3  
Storage Cell: %1 EM: Local Notification Host List File Unavailable Event Code: %2  
Description: %3  
Storage Cell: %1 EM: SCMI returns zero SC Events but reports additional events Event  
Code: %2 Description: %3  
23041 88035a01  
23042 88035a02  
23043 88035a03  
2
2
2
3041  
3042  
3043  
Storage Cell: %1 Undefined Status Code Event Code: %2 Description: %3  
Storage Cell: %1 Status Code Not Found Event Code: %2 Description: %3  
Storage Cell: %1 EM Failed SC Init - couldn’t retrieve SC Event Event Code: %2  
Description: %3  
23044 88035a04  
23045 88035a05  
23046 88035a06  
23047 88035a07  
23048 88035a08  
23049 88035a09  
23050 88035a0a  
23051 88035a0b  
23052 88035a0c  
23053 88035a0d  
23054 88035a0e  
23055 88035a0f  
23056 88035a10  
2
2
2
3
2
2
6
3
3
2
2
3
2
3044  
3045  
3046  
3047  
3048  
3049  
3050  
3051  
3052  
3053  
3054  
3055  
3056  
Storage Cell: %1 Override this description with missing filename Event Code: %2  
Description: %3  
Storage Cell: %1 Invalid storage system event sequence number - can’t retrieve event  
Event Code: %2 Description: %3  
Storage Cell: %1 Invalid SC termination event sequence number - can’t retrieve event  
Event Code: %2 Description: %3  
Storage Cell: %1 EM: Event config file unavailable from MLD - retrieving local backup  
copy Event Code: %2 Description: %3  
Storage Cell: %1 EM: Local user defined event state file unavailable Event Code: %2  
Description: %3  
Storage Cell: %1 EM: EMU event monitoring thread unable to start Event Code: %2  
Description: %3  
Storage Cell: %1 EM: EMU event - this description will be overwritten Event Code: %2  
Description: %3  
Storage Cell: %1 EM: Failed to write Event Config file to MLD Event Code: %2  
Description: %3  
Storage Cell: %1 EM: Failed to write Notification Host List to MLD Event Code: %2  
Description: %3  
Storage Cell: %1 EM: Event Configiguration Filename Error or File empty Event Code:  
%2 Description: %3  
Storage Cell: %1 EM: Notification Hostlist Filename Error or File empty Event Code: %2  
Description: %3  
Storage Cell: %1 EM: Event Config List Object Reference Error Event Code: %2  
Description: %3  
Storage Cell: %1 EM: SC Parse File successfully uploaded Event Code: %2 Description:  
%3  
23057 88035a11  
23058 88035a12  
2
3
3057  
3058  
Storage Cell: %1 EM: SC Parse File upload failed Event Code: %2 Description: %3  
Storage Cell: %1 EM: Contents of the uploaded parse file invalid - unexpected contents  
Event Code: %2 Description: %3  
23059 88035a13  
23060 88035a14  
3
6
3059  
3060  
Storage Cell: %1 EM: Parse file is empty Event Code: %2 Description: %3  
Storage Cell: %1 Storage system being shutdown due to a command failure. Event  
Code: %2 Description: %3  
23061 88035a15  
2
3061  
Storage Cell: %1 EM: Could not retrieve a storage system event Event Code: %2  
Description: %3  
Storage Management Appliance Software Event Code Definitions Application Notes  
61  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
23062 88035a16  
23063 88035a17  
2
3
3062  
3063  
Storage Cell: %1 EM: Init SC Event config list failed Event Code: %2 Description: %3  
Storage Cell: %1 Could not initialize Comm infrastructure for event logging to system log  
Event Code: %2 Description: %3  
23064 88035a18  
23065 88035a19  
6
6
3064  
3065  
Storage Cell: %1 EM: Storage system pointer is NULL! Event Code: %2 Description: %3  
Storage Cell: %1 EM: Failed to log event to the Appliance event log: check if log is full  
Event Code: %2 Description: %3  
23066 88035a1a  
3
3
6
6
6
3
3
6
3
2
3
2
2
2
6
3066  
3067  
3068  
3069  
3070  
3071  
3072  
3073  
3074  
3075  
3076  
3077  
3078  
3079  
3080  
Storage Cell: %1 EM: Description Mngr Init StorageCell Failed Event Code: %2  
Description: %3  
23067  
88035a1b  
Storage Cell: %1 EM: Description file too small. File read problem Or Incomplete file.  
Event Code: %2 Description: %3  
23068 88035a1c  
23069 88035a1d  
Storage Cell: %1 EM: Can’t init NT Event object pointer Event Code: %2 Description:  
%3  
Storage Cell: %1 EM: Can’t init NT Notification object pointer Event Code: %2  
Description: %3  
23070  
88035a1e  
Storage Cell: %1 EM: Appliance Event Logging Failure - log may be full Event Code:  
%2 Description: %3  
23071 88035a1f  
Storage Cell: %1 EM: SCMI returned bad additional events number Event Code: %2  
Description: %3  
23072  
23073  
23074  
23075  
23076  
88035a20  
88035a21  
88035a22  
88035a23  
88035a24  
Storage Cell: %1 EM: SCMI returned zero sized SC Event Event Code: %2 Description:  
%3  
Storage Cell: %1 EM: Local event file Size exceeds max size - event logging shutdown  
Event Code: %2 Description: %3  
Storage Cell: %1 EM: Local event file exceeded max size limit - truncating file Event  
Code: %2 Description: %3  
Storage Cell: %1 EventQueue index passed is out of bounds Event Code: %2  
Description: %3  
Storage Cell: %1 EM: An abnormal number of duplicate events logged - dropping  
duplicates Event Code: %2 Description: %3  
23077 88035a25  
Storage Cell: %1 EM: Update of the MLD Status Description file failed Event Code: %2  
Description: %3  
23078  
23079  
88035a26  
88035a27  
Storage Cell: %1 EM: NsaStatusDescriptions.txt open file error Event Code: %2  
Description: %3  
Storage Cell: %1 EM: NsaStatusDescriptions.txt file error - file size discrepency from mld  
list Event Code: %2 Description: %3  
23080 88035a28  
Storage Cell: %1 SC Event Log has been cleared and restarted. Possible RAID1  
Meltdown. Event Code: %2 Description: %3  
23081 88035a29  
23082 88035a2a  
23083 88035a2b  
23084 88035a2c  
2
2
2
2
3081  
3082  
3083  
3084  
Storage Cell: %1 Invalid logType parameter Event Code: %2 Description: %3  
Storage Cell: %1 Unsupported version Event Code: %2 Description: %3  
Storage Cell: %1 Log file is empty Event Code: %2 Description: %3  
Storage Cell: %1 Storage System with this WWN is not visible to this agent or the  
WWN is invalid Event Code: %2 Description: %3  
23085 88035a2d  
23086 88035a2e  
6
2
3085  
3086  
Storage Cell: %1 Pointer to Event Manager is NULL Event Code: %2 Description: %3  
Storage Cell: %1 Parsefile for current firmware version not found. Upload correct parse  
file. Event Code: %2 Description: %3  
62  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
23090 88035a32  
2
3090  
Storage Cell: %1 The contents of this file appear to be invalid Event Code: %2  
Description: %3  
23091 88035a33  
2
3091  
Storage Cell: %1 The MIB failed to build due to a missing parse file. Event Code: %2  
Description: %3  
24000 88035dc0  
24001 88035dc1  
24002 88035dc2  
24003 88035dc3  
24004 88035dc4  
24005 88035dc5  
24006 88035dc6  
24007 88035dc7  
24008 88035dc8  
24009 88035dc9  
2
2
2
2
2
2
2
2
2
2
4000  
4001  
4002  
4003  
4004  
4005  
4006  
4007  
4008  
4009  
Storage Cell: %1 MLD Manager Subsystem Error Event Code: %2 Description: %3  
Storage Cell: %1 MLD Manager Offline Event Code: %2 Description: %3  
Storage Cell: %1 MLD Manager Online Event Code: %2 Description: %3  
Storage Cell: %1 MLD Manager Startup Failed Event Code: %2 Description: %3  
Storage Cell: %1 MLD Manager Startup Complete Event Code: %2 Description: %3  
Storage Cell: %1 MLD Manager Abnormal Startup Event Code: %2 Description: %3  
Storage Cell: %1 MLD Manager Shutdown Failed Event Code: %2 Description: %3  
Storage Cell: %1 MLD Manager Shutdown Complete Event Code: %2 Description: %3  
Storage Cell: %1 MLD Manager Abnormal Shutdown Event Code: %2 Description: %3  
Storage Cell: %1 Unable to startup WSA during MldMgr:init Event Code: %2  
Description: %3  
24010 88035dca  
2
4010  
Storage Cell: %1 Unable to get Server Host Name during MldMgr:init Event Code: %2  
Description: %3  
24011 88035dcb  
24012 88035dcc  
2
2
4011  
4012  
Storage Cell: %1 Invalid Host IP Address specified Event Code: %2 Description: %3  
Storage Cell: %1 Unable to open the NsaMldMgr.dat file for Write Event Code: %2  
Description: %3  
24013 88035dcd  
2
4013  
Storage Cell: %1 Unable to open the NsaMldMgr.dat file for Read Event Code: %2  
Description: %3  
24014 88035dce  
24015 88035dcf  
24016 88035dd0  
24017 88035dd1  
24018 88035dd2  
24019 88035dd3  
24020 88035dd4  
24021 88035dd5  
24022 88035dd6  
24023 88035dd7  
24024 88035dd8  
24025 88035dd9  
24026 88035dda  
24027 88035ddb  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
4014  
4015  
4016  
4017  
4018  
4019  
4020  
4021  
4022  
4023  
4024  
4025  
4026  
4027  
Storage Cell: %1 Agent Uid does not exist Event Code: %2 Description: %3  
Storage Cell: %1 Unable to find Object Event Code: %2 Description: %3  
Storage Cell: %1 Unable to store Object Event Code: %2 Description: %3  
Storage Cell: %1 Unable to find Object Cell Event Code: %2 Description: %3  
Storage Cell: %1 Unable to create MLD Event Code: %2 Description: %3  
Storage Cell: %1 lastSafeChoiceDelay Expired Event Code: %2 Description: %3  
Storage Cell: %1 lastSafeChoiceDelay Expired Event Code: %2 Description: %3  
Storage Cell: %1 crashDetectDelay Expired Event Code: %2 Description: %3  
Storage Cell: %1 retSCCBNum not an SCCB Num Event Code: %2 Description: %3  
Storage Cell: %1 Unable to read Copy1 of MLD Event Code: %2 Description: %3  
Storage Cell: %1 Copy 1 of MLD Invalid Event Code: %2 Description: %3  
Storage Cell: %1 Invalid Copy block of MLD Event Code: %2 Description: %3  
Storage Cell: %1 Copy 2 of MLD Invalid Event Code: %2 Description: %3  
Storage Cell: %1 MLD database capacity not equal to true MLD capacity Event Code:  
%2 Description: %3  
24028 88035ddc  
24029 88035ddd  
24030 88035dde  
2
2
2
4028  
4029  
4030  
Storage Cell: %1 Backup range out of bounds of copy 1 range Event Code: %2  
Description: %3  
Storage Cell: %1 MLD Manager Lock Crash DetectDelay has expired, just taking lock!  
Event Code: %2 Description: %3  
Storage Cell: %1 MLD Copy 1 Restored Event Code: %2 Description: %3  
Storage Management Appliance Software Event Code Definitions Application Notes  
63  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
24031 88035ddf  
24032 88035de0  
24033 88035de1  
2
2
2
4031  
4032  
4033  
Storage Cell: %1 MLD Copy 2 Restored Event Code: %2 Description: %3  
Storage Cell: %1 Unable to find UidAssoc Object Event Code: %2 Description: %3  
Storage Cell: %1 Unable to store UID Association Object Event Code: %2 Description:  
%3  
24034 88035de2  
24035 88035de3  
2
2
4034  
4035  
Storage Cell: %1 Unable to find UidAssoc Object Event Code: %2 Description: %3  
Storage Cell: %1 Unable to read last Fusion event read Event Code: %2 Description:  
%3  
24036 88035de4  
24037 88035de5  
24038 88035de6  
24039 88035de7  
24040 88035de8  
24041 88035de9  
24042 88035dea  
24043 88035deb  
24044 88035dec  
2
2
2
2
2
2
2
2
2
4036  
4037  
4038  
4039  
4040  
4041  
4042  
4043  
4044  
Storage Cell: %1 MLD Notification Queue Empty Event Code: %2 Description: %3  
Storage Cell: %1 Unable to find Notification Object Event Code: %2 Description: %3  
Storage Cell: %1 Unable to store Notification Object Event Code: %2 Description: %3  
Storage Cell: %1 Unable to find Notification Object Event Code: %2 Description: %3  
Storage Cell: %1 Unable to read Event Log Pointer Event Code: %2 Description: %3  
Storage Cell: %1 Unable to read Event Log Event Code: %2 Description: %3  
Storage Cell: %1 Unable to store Event Log Event Code: %2 Description: %3  
Storage Cell: %1 Unable to read Event Log Event Code: %2 Description: %3  
Storage Cell: %1 Unable to read Event Log and free Lock Event Code: %2 Description:  
%3  
24045 88035ded  
24046 88035dee  
24047 88035def  
24048 88035df0  
24049 88035df1  
2
2
2
2
2
4045  
4046  
4047  
4048  
4049  
Storage Cell: %1 Unable to store Event Log and free Lock Event Code: %2 Description:  
%3  
Storage Cell: %1 Unable to read Event Log and free Lock Event Code: %2 Description:  
%3  
Storage Cell: %1 Previously Read Object Properties do not Match Event Code: %2  
Description: %3  
Storage Cell: %1 Previously Read Object Properties do not Match Event Code: %2  
Description: %3  
Storage Cell: %1 Unable to read Notification Host List Event Code: %2 Description:  
%3  
24050 88035df2  
24051 88035df3  
2
2
4050  
4051  
Storage Cell: %1 Unable to store Notification Host List Event Code: %2 Description: %3  
Storage Cell: %1 Unable to store Notification Host List and free Lock Event Code: %2  
Description: %3  
24052 88035df4  
24053 88035df5  
24054 88035df6  
2
2
2
4052  
4053  
4054  
Storage Cell: %1 Unable to read Event Configuration List Event Code: %2 Description:  
%3  
Storage Cell: %1 Unable to store Event Configuration List Event Code: %2 Description:  
%3  
Storage Cell: %1 Unable to store Event Configuration List and free Lock Event Code: %2  
Description: %3  
24055 88035df7  
24056 88035df8  
24057 88035df9  
24058 88035dfa  
24059 88035dfb  
25001 880361a9  
25002 880361aa  
2
2
2
2
2
2
2
4055  
4056  
4057  
4058  
4059  
5001  
5002  
Storage Cell: %1 MLD roll up buffer full Event Code: %2 Description: %3  
Storage Cell: %1 MLD roll up list read error Event Code: %2 Description: %3  
Storage Cell: %1 MLD Monitor Lock error Event Code: %2 Description: %3  
Storage Cell: %1 MLD Manager Mutex Timeout error Event Code: %2 Description: %3  
Storage Cell: %1 MLD Manager list is empty Event Code: %2 Description: %3  
Storage Cell: %1 Monitor Startup Complete Event Code: %2 Description: %3  
Storage Cell: %1 Monitor Startup Failed Event Code: %2 Description: %3  
64  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
25003 880361ab  
25004 880361ac  
25005 880361ad  
25006 880361ae  
25007 880361af  
25008 880361b0  
2
6
2
2
2
2
5003  
5004  
5005  
5006  
5007  
5008  
Storage Cell: %1 Monitor ShutDown Complete Event Code: %2 Description: %3  
Storage Cell: %1 Monitor Memory Allocation Failure Event Code: %2 Description: %3  
Storage Cell: %1 Monitor Mark Agent as Inactive Event Code: %2 Description: %3  
Storage Cell: %1 Monitor create thread error Event Code: %2 Description: %3  
Storage Cell: %1 Monitor create timer error Event Code: %2 Description: %3  
Storage Cell: %1 Monitor agent registration - Complete Event Code: %2 Description:  
%3  
25009 880361b1  
25010 880361b2  
25011 880361b3  
25012 880361b4  
25013 880361b5  
25014 880361b6  
25015 880361b7  
25016 880361b8  
25017 880361b9  
25018 880361ba  
25019 880361bb  
2
2
2
2
2
2
2
2
2
2
2
5009  
5010  
5011  
5012  
5013  
5014  
5015  
5016  
5017  
5018  
5019  
Storage Cell: %1 Monitor controller rediscovery - Complete Event Code: %2  
Description: %3  
Storage Cell: %1 Monitor initiated a storage system shutdown because of controller  
failure Event Code: %2 Description: %3  
Storage Cell: %1 Unknown storage system rediscovery complete Event Code: %2  
Description: %3  
Storage Cell: %1 Start monitoring thread for storage system - Complete Event Code: %2  
Description: %3  
Storage Cell: %1 Start monitoring thread for storage system - Fail Event Code: %2  
Description: %3  
Storage Cell: %1 Monitoring thread for storage system terminated Event Code: %2  
Description: %3  
Storage Cell: %1 Rediscover unknown storage system - Error Event Code: %2  
Description: %3  
Storage Cell: %1 Controller time synchronized to appliance time. Event Code: %2  
Description: %3  
Storage Cell: %1 Appliance and controller time checked for synchronization. Event  
Code: %2 Description: %3  
Storage Cell: %1 Controller and appliance time are the same. No need to synchronize.  
Event Code: %2 Description: %3  
Storage Cell: %1 Exception caught in monitoring process. Event Code: %2 Description:  
%3  
26001 88036591  
26002 88036592  
26003 88036593  
2
2
6
6001  
6002  
6003  
Storage Cell: %1 Nsc Manager Ready Event Code: %2 Description: %3  
Storage Cell: %1 Nsc Manager Index Out of Range Event Code: %2 Description: %3  
Storage Cell: %1 Cannot access storage system. Communications error. Event Code:  
%2 Description: %3  
26004 88036594  
26005 88036595  
26006 88036596  
2
2
6
6004  
6005  
6006  
Storage Cell: %1 Nsc Manager No NSCs Found Event Code: %2 Description: %3  
Storage Cell: %1 Nsc Manager Invalid Index Event Code: %2 Description: %3  
Storage Cell: %1 Nsc Manager Memory Allocation Failure Event Code: %2  
Description: %3  
26007 88036597  
26008 88036598  
2
2
6007  
6008  
Storage Cell: %1 Nsc Manager No Physical Stores Found Event Code: %2 Description:  
%3  
Storage Cell: %1 Nsc Manager No Storage Cell Found Event Code: %2 Description:  
%3  
26009 88036599  
26010 8803659a  
26011 8803659b  
2
2
2
6009  
6010  
6011  
Storage Cell: %1 Nsc Manager No disk group Found Event Code: %2 Description: %3  
Storage Cell: %1 Nsc Manager too many disk groups Event Code: %2 Description: %3  
Storage Cell: %1 Nsc Manager No Volumes Found Event Code: %2 Description: %3  
Storage Management Appliance Software Event Code Definitions Application Notes  
65  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
26012 8803659c  
2
6012  
Storage Cell: %1 Nsc Manager No Logical Disks Found Event Code: %2 Description:  
%3  
26013 8803659d  
2
6013  
Storage Cell: %1 Nsc Manager Context Id Changed During Operation Event Code: %2  
Description: %3  
26014 8803659e  
26015 8803659f  
26016 880365a0  
26017 880365a1  
2
2
2
2
6014  
6015  
6016  
6017  
Storage Cell: %1 Nsc Manager No Name Event Code: %2 Description: %3  
Storage Cell: %1 Nsc Manager Name Size Exceeded Event Code: %2 Description: %3  
Storage Cell: %1 Nsc Manager Shutdown Complete Event Code: %2 Description: %3  
Storage Cell: %1 Nsc Manager Mutex Creation Failure Event Code: %2 Description:  
%3  
26018 880365a2  
26019 880365a3  
26020 880365a4  
2
2
2
6018  
6019  
6020  
Storage Cell: %1 Nsc Manager Mutex Timeout Event Code: %2 Description: %3  
Storage Cell: %1 Nsc Manager No MLD Handle Set Event Code: %2 Description: %3  
Storage Cell: %1 Nsc Manager Failed Transport Layer Communication - No Such Id  
Event Code: %2 Description: %3  
26021 880365a5  
26022 880365a6  
2
2
2
2
2
2
2
2
6021  
6022  
6023  
6024  
6025  
6026  
6027  
6028  
Storage Cell: %1 Nsc Manager Failed Transport Layer Communication - TimeOut Event  
Code: %2 Description: %3  
Storage Cell: %1 Nsc Manager No Storage Cell Objects Found Event Code: %2  
Description: %3  
26023  
26024  
880365a7  
880365a8  
Storage Cell: %1 Nsc Manager No Attached Port Found Event Code: %2 Description:  
%3  
Storage Cell: %1 Nsc Manager Failed to get SCMI Object Handle Event Code: %2  
Description: %3  
26025 880365a9  
26026 880365aa  
Storage Cell: %1 Shutdown Both Restart And Power Off Requested Event Code: %2  
Description: %3  
Storage Cell: %1 Shutdown Drive Shelf Power Off But No Enclosure Power Off Requested  
Event Code: %2 Description: %3  
26027 880365ab  
26028 880365ac  
Storage Cell: %1 Shutdown Disable Battery But No Enclosure Power Off Requested  
Event Code: %2 Description: %3  
Storage Cell: %1 Shutdown Disable Battery But Shutdown Unconditional Requested  
Event Code: %2 Description: %3  
26029 880365ad  
26030 880365ae  
26031 880365af  
26032 880365b0  
26033 880365b1  
2
2
2
2
2
6029  
6030  
6031  
6032  
6033  
Storage Cell: %1 Shutdown Delay Out Of Range Event Code: %2 Description: %3  
Storage Cell: %1 Cache Write Failure Event Code: %2 Description: %3  
Storage Cell: %1 Battery Disable Failure Event Code: %2 Description: %3  
Storage Cell: %1 Drive Shelf Disable Failure Event Code: %2 Description: %3  
Storage Cell: %1 Battery Disable Failed on Both Controllers Batteries Event Code: %2  
Description: %3  
26034 880365b2  
26035 880365b3  
26036 880365b4  
2
2
2
2
2
6034  
6035  
6036  
6037  
6038  
Storage Cell: %1 Battery Disable Failed on This Controllers Battery Event Code: %2  
Description: %3  
Storage Cell: %1 Battery Disable Failed on the Other Controllers Battery Event Code:  
%2 Description: %3  
Storage Cell: %1 Requested disk failure protection level is set. Actual level will change  
when sufficient disk space is available. Event Code: %2 Description: %3  
26037  
880365b5  
Storage Cell: %1 Physical Store Contains Stale or Foreign Volume Information. Event  
Code: %2 Description: %3  
26038 880365b6  
Storage Cell: %1 Controller Resynchronization or Reboot Occurred. Context Error Event  
Code: %2 Description: %3  
66  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
26039 880365b7  
27001 88036979  
2
2
2
2
2
2
6039  
7001  
7002  
7003  
7004  
7005  
Storage Cell: %1 Bad Command Or Response Cookie Event Code: %2 Description: %3  
Storage Cell: %1 More than one storage system found Event Code: %2 Description: %3  
Storage Cell: %1 Storage system already exists Event Code: %2 Description: %3  
Storage Cell: %1 Storage System is not initialized Event Code: %2 Description: %3  
Storage Cell: %1 Storage Object Mngr Ready Event Code: %2 Description: %3  
27002  
8803697a  
27003 8803697b  
27004 8803697c  
27005 8803697d  
Storage Cell: %1 Storage Object Mngr Shutdown Complete Event Code: %2  
Description: %3  
27006 8803697e  
28001 88036d61  
28002 88036d62  
28003 88036d63  
2
2
2
2
7006  
8001  
8002  
8003  
Storage Cell: %1 Storage system name too long Event Code: %2 Description: %3  
Storage Cell: %1 Invalid Operation Event Code: %2 Description: %3  
Storage Cell: %1 Storage system already created Event Code: %2 Description: %3  
Storage Cell: %1 Controller already part of storage system configuration Event Code:  
%2 Description: %3  
28004 88036d64  
28005 88036d65  
2
2
8004  
8005  
Storage Cell: %1 Physical Store Count Below Minimum Event Code: %2 Description:  
%3  
Storage Cell: %1 Controller not part of storage system configuration Event Code: %2  
Description: %3  
28006 88036d66  
28007 88036d67  
28008 88036d68  
28009 88036d69  
28010 88036d6a  
28011 88036d6b  
28012 88036d6c  
28013 88036d6d  
28014 88036d6e  
28015 88036d6f  
28016 88036d70  
28017 88036d71  
28018 88036d72  
28019 88036d73  
28020 88036d74  
28021 88036d75  
28022 88036d76  
28023 88036d77  
28024 88036d78  
28025 88036d79  
2
3
3
3
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
8006  
8007  
8008  
8009  
8010  
8011  
8012  
8013  
8014  
8015  
8016  
8017  
8018  
8019  
8020  
8021  
8022  
8023  
8024  
8025  
Storage Cell: %1 Failed to uninitialize storage system Event Code: %2 Description: %3  
Storage Cell: %1 Storage system File Open Error Event Code: %2 Description: %3  
Storage Cell: %1 Storage system File Write Error Event Code: %2 Description: %3  
Storage Cell: %1 Storage system File Read Error Event Code: %2 Description: %3  
Storage Cell: %1 Name too long Event Code: %2 Description: %3  
Storage Cell: %1 No String Error Event Code: %2 Description: %3  
Storage Cell: %1 No MLD Handle Found Event Code: %2 Description: %3  
Storage Cell: %1 No Controllers Found Event Code: %2 Description: %3  
Storage Cell: %1 Controller Not Found On Loop Event Code: %2 Description: %3  
Storage Cell: %1 No Disk Groups Found Event Code: %2 Description: %3  
Storage Cell: %1 No Volumes Found Event Code: %2 Description: %3  
Storage Cell: %1 No Physical Stores Found Event Code: %2 Description: %3  
Storage Cell: %1 No Virtual Disks Found Event Code: %2 Description: %3  
Storage Cell: %1 No Hosts Found Event Code: %2 Description: %3  
Storage Cell: %1 Name already exists Event Code: %2 Description: %3  
Storage Cell: %1 Folder is not empty Event Code: %2 Description: %3  
Storage Cell: %1 Spares goal could not be met Event Code: %2 Description: %3  
Storage Cell: %1 Storage system object found Event Code: %2 Description: %3  
Storage Cell: %1 Storage system object not found Event Code: %2 Description: %3  
Storage Cell: %1 New Physical Store Detected But Not Found In Physical Store List Event  
Code: %2 Description: %3  
28026 88036d7a  
28027 88036d7b  
28028 88036d7c  
28029 88036d7d  
3
3
3
6
8026  
8027  
8028  
8029  
Storage Cell: %1 MldManager Handle is NULL Event Code: %2 Description: %3  
Storage Cell: %1 NscMngrInterface Handle is NULL Event Code: %2 Description: %3  
Storage Cell: %1 ScLockMngr Handle is NULL Event Code: %2 Description: %3  
Storage Cell: %1 Storage system initialization failed Event Code: %2 Description: %3  
Storage Management Appliance Software Event Code Definitions Application Notes  
67  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
28030 88036d7e  
3
8030  
Storage Cell: %1 MldMngr, NscMngrInterfaceMngr, or ScLockMngr Handle is NULL  
Event Code: %2 Description: %3  
28031 88036d7f  
28032 88036d80  
28033 88036d81  
6
3
2
8031  
8032  
8033  
Storage Cell: %1 Storage system initilization failed Event Code: %2 Description: %3  
Storage Cell: %1 Storage system discovery failed Event Code: %2 Description: %3  
Storage Cell: %1 Storage system already uninitialized or does not exist Event Code: %2  
Description: %3  
28034 88036d82  
28035 88036d83  
28036 88036d84  
28037 88036d85  
28038 88036d86  
28039 88036d87  
28040 88036d88  
28041 88036d89  
28042 88036d8a  
28043 88036d8b  
28044 88036d8c  
28045 88036d8d  
28046 88036d8e  
28047 88036d8f  
28048 88036d90  
28049 88036d91  
28050 88036d92  
28051 88036d93  
28052 88036d94  
28053 88036d95  
28054 88036d96  
28055 88036d97  
28056 88036d98  
28057 88036d99  
3
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
8034  
8035  
8036  
8037  
8038  
8039  
8040  
8041  
8042  
8043  
8044  
8045  
8046  
8047  
8048  
8049  
8050  
8051  
8052  
8053  
8054  
8055  
8056  
8057  
Storage Cell: %1 Get Total Storage Failed Event Code: %2 Description: %3  
Storage Cell: %1 Storage system is uninitialized Event Code: %2 Description: %3  
Storage Cell: %1 Get Total Storage Available Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Total Storage Occupied Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Total Storage Free Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Disk Group Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Disk Group List Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Disk Group Count Failed Event Code: %2 Description: %3  
Storage Cell: %1 Create Volume Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Volume Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Volumes Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Volumes Count Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Virtual Disk Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Virtual Disk List Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Physical Store Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Physical Stores Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Physical Stores Count Failed Event Code: %2 Description: %3  
Storage Cell: %1 Create Virtual Disk Failed Event Code: %2 Description: %3  
Storage Cell: %1 Delete Virtual Disk Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Device Addition Policy Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Spares Current Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Spares Goal Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get storage system events failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Volume Replacement Delay Failed Event Code: %2 Description:  
%3  
28058 88036d9a  
28059 88036d9b  
28060 88036d9c  
3
3
3
8058  
8059  
8060  
Storage Cell: %1 Set Device Addition Policy Failed Event Code: %2 Description: %3  
Storage Cell: %1 Set Spares Goal Failed Event Code: %2 Description: %3  
Storage Cell: %1 Set Volume Replacement Delay Failed Event Code: %2 Description:  
%3  
28061 88036d9d  
28062 88036d9e  
28063 88036d9f  
28064 88036da0  
28065 88036da1  
28066 88036da2  
3
3
3
3
3
3
8061  
8062  
8063  
8064  
8065  
8066  
Storage Cell: %1 Create NSC Failed Event Code: %2 Description: %3  
Storage Cell: %1 Update NSC Failed Event Code: %2 Description: %3  
Storage Cell: %1 Create Host Failed Event Code: %2 Description: %3  
Storage Cell: %1 Discard Host Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Host Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Host List Failed Event Code: %2 Description: %3  
68  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
28067 88036da3  
28068 88036da4  
28069 88036da5  
3
3
3
3
3
3
8067  
8068  
8069  
8070  
8071  
8072  
Storage Cell: %1 Get Host Count Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Presented Unit List Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Presented Unit Count Failed Event Code: %2 Description: %3  
Storage Cell: %1 Free View Failed Event Code: %2 Description: %3  
28070  
88036da6  
28071 88036da7  
Storage Cell: %1 Storage system shutdown Failed Event Code: %2 Description: %3  
28072  
88036da8  
Storage Cell: %1 StorageCell Virtual Disk Count Does Not Match Logical Disk Count  
Event Code: %2 Description: %3  
28073  
28074  
28075  
88036da9  
88036daa  
88036dab  
3
3
3
8073  
8074  
8075  
Storage Cell: %1 Get Derived Unit List Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get Derived Unit Count Failed Event Code: %2 Description: %3  
Storage Cell: %1 Get StorageCell Virtual Disk List Failed Event Code: %2 Description:  
%3  
28076  
88036dac  
3
3
8076  
8077  
Storage Cell: %1 Get StorageCell Virtual Disk Count Failed Event Code: %2  
Description: %3  
28077 88036dad  
Storage Cell: %1 Error while building virtual disk root view Event Code: %2  
Description: %3  
28078  
28079  
88036dae  
88036daf  
3
3
8078  
8079  
Storage Cell: %1 Error while building host root view Event Code: %2 Description: %3  
Storage Cell: %1 Error while uilding disk group root view Event Code: %2 Description:  
%3  
28080 88036db0  
3
8080  
Storage Cell: %1 Error while building hardware root view Event Code: %2 Description:  
%3  
28081 88036db1  
28082 88036db2  
3
3
8081  
8082  
Storage Cell: %1 Specified time format is incorrect Event Code: %2 Description: %3  
Storage Cell: %1 Error creating/opening time syncronization file. Event Code: %2  
Description: %3  
28083 88036db3  
28084 88036db4  
29001 88037149  
29002 8803714a  
29003 8803714b  
29004 8803714c  
29005 8803714d  
29006 8803714e  
29007 8803714f  
29008 88037150  
29009 88037151  
3
3
3
3
3
2
2
2
2
2
2
8083  
8084  
9001  
9002  
9003  
9004  
9005  
9006  
9007  
9008  
9009  
Storage Cell: %1 StorageCell NscList Reordered. Event Code: %2 Description: %3  
Storage Cell: %1 StorageCell NscList Mutex Get Error Event Code: %2 Description: %3  
Storage Cell: %1 Virtual disk File Open Error Event Code: %2 Description: %3  
Storage Cell: %1 Virtual disk File Write Error Event Code: %2 Description: %3  
Storage Cell: %1 Virtual disk File Read Error Event Code: %2 Description: %3  
Storage Cell: %1 Virtual disk name too long Event Code: %2 Description: %3  
Storage Cell: %1 Virtual disk No String Error Event Code: %2 Description: %3  
Storage Cell: %1 Virtual disk No Object Error Event Code: %2 Description: %3  
Storage Cell: %1 Virtual disk still exists Event Code: %2 Description: %3  
Storage Cell: %1 Virtual disk Invalid Value Event Code: %2 Description: %3  
Storage Cell: %1 An outstanding command is still in progress for the virtual disk Event  
Code: %2 Description: %3  
29010 88037152  
29011 88037153  
29012 88037154  
29013 88037155  
2
2
2
2
9010  
9011  
9012  
9013  
Storage Cell: %1 Requested virtual disk size exceeds the available size Event Code: %2  
Description: %3  
Storage Cell: %1 Virtual disk size may be expanded but not reduced Event Code: %2  
Description: %3  
Storage Cell: %1 Operation on a fast virtual disk deletion completed Event Code: %2  
Description: %3  
Storage Cell: %1 Operation on a fast virtual disk creation completed Event Code: %2  
Description: %3  
Storage Management Appliance Software Event Code Definitions Application Notes  
69  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
29014 88037156  
2
9014  
Storage Cell: %1 Operation on a fast virtual disk size expansion completed Event  
Code: %2 Description: %3  
29015 88037157  
29016 88037158  
29017 88037159  
2
2
2
9015  
9016  
9017  
Storage Cell: %1 Virtual disk cache data lost error Event Code: %2 Description: %3  
Storage Cell: %1 Virtual disk data lost error resolved Event Code: %2 Description: %3  
Storage Cell: %1 Operation rejected - The virtual disk has a sharing relationship with  
another object Event Code: %2 Description: %3  
29018 8803715a  
29019 8803715b  
29020 8803715c  
29021 8803715d  
29022 8803715e  
29023 8803715f  
2
2
2
2
2
2
9018  
9019  
9020  
9021  
9022  
9023  
Storage Cell: %1 Operation on this virtual disk was rejected due to the unit’s not normal  
condition Event Code: %2 Description: %3  
Storage Cell: %1 Operation on this virtual disk could only be performed if unit is  
presented to a host Event Code: %2 Description: %3  
Storage Cell: %1 Cache policies cannot be modified if unit is presented to a host Event  
Code: %2 Description: %3  
Storage Cell: %1 Allowed property changes successful. (Cache policy changes not  
allowed, while virtual disk is presented to a host.) Event Code: %2 Description: %3  
Storage Cell: %1 Requested redundancy type cannot be implemented with the current  
disk group condition. Event Code: %2 Description: %3  
Storage Cell: %1 Your unit was created but cannot be presented at this time. Continue to  
check your unit and present it later when it is fully allocated. Event Code: %2  
Description: %3  
29024 88037160  
2
9024  
Storage Cell: %1 Operation would exceed the maximum allowable presented units.  
Event Code: %2 Description: %3  
29025 88037161  
29026 88037162  
2
2
9025  
9026  
Storage Cell: %1 Virtual Disk Device Data Lost Error Event Code: %2 Description: %3  
Storage Cell: %1 The Most Significant Hex Character in a World Wide LUN Name must  
be a 6 Event Code: %2 Description: %3  
29027 88037163  
29028 88037164  
29029 88037165  
2
2
2
9027  
9028  
9029  
Storage Cell: %1 Virtual disk cache and inoperative data lost error Event Code: %2  
Description: %3  
Storage Cell: %1 Virtual disk inoperative data lost error Event Code: %2 Description:  
%3  
Storage Cell: %1 Virtual disk condition failed because of an inoperative data lost error.  
Event Code: %2 Description: %3  
30001 88037531  
30002 88037532  
30003 88037533  
30004 88037534  
30005 88037535  
30006 88037536  
30007 88037537  
30008 88037538  
30009 88037539  
2
3
2
2
2
6
2
2
2
10001 Storage Cell: %1 Storage Object Broker Ready Event Code: %2 Description: %3  
10002 Storage Cell: %1 Storage Object Startup Failed Event Code: %2 Description: %3  
10003 Storage Cell: %1 Invalid storage system name Event Code: %2 Description: %3  
10004 Storage Cell: %1 Storage system is not Initialized Event Code: %2 Description: %3  
10005 Storage Cell: %1 Failed to set storage system name Event Code: %2 Description: %3  
10006 Storage Cell: %1 SOB Memory Allocation Failure Event Code: %2 Description: %3  
10007 Storage Cell: %1 Failed to find virtual disk from list Event Code: %2 Description: %3  
10008 Storage Cell: %1 Failed to find host from list Event Code: %2 Description: %3  
10009 Storage Cell: %1 The Lun specified for this Host is already in use Event Code: %2  
Description: %3  
30010 8803753a  
30011 8803753b  
2
2
10010 Storage Cell: %1 Your initialized system must have at least one disk group Event Code:  
%2 Description: %3  
10011 Storage Cell: %1 Cannot talk to all available NSCs Event Code: %2 Description: %3  
70  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
30012 8803753c  
30013 8803753d  
30014 8803753e  
30015 8803753f  
30016 88037540  
30017 88037541  
2
2
2
2
2
2
10012 Storage Cell: %1 Command rejected - Folder is not empty Event Code: %2 Description:  
%3  
10013 Storage Cell: %1 Command rejected - There are virtual disk(s) attached to this disk  
group Event Code: %2 Description: %3  
10014 Storage Cell: %1 Command rejected - There are virtual disk(s) presented to this host  
Event Code: %2 Description: %3  
10015 Storage Cell: %1 Command rejected - The virtual disk has a sharing relationship with  
another object Event Code: %2 Description: %3  
10016 Storage Cell: %1 Target storage system is currently being used by another process Event  
Code: %2 Description: %3  
10017 Storage Cell: %1 Command rejected - Number of disk groups will exceed the maximum  
allowable number Event Code: %2 Description: %3  
30018 88037542  
30019 88037543  
30020 88037544  
2
2
2
10018 Storage Cell: %1 Cannot access the password file Event Code: %2 Description: %3  
10019 Storage Cell: %1 Enterprise Login - Complete Event Code: %2 Description: %3  
10020 Storage Cell: %1 Operation rejected - Storage system should conform with the number  
of minimum member devices. Event Code: %2 Description: %3  
30021 88037545  
30022 88037546  
30023 88037547  
30024 88037548  
30025 88037549  
30026 8803754a  
30027 8803754b  
2
2
2
2
2
2
2
10021 Storage Cell: %1 Rediscovery of controllers - Complete Event Code: %2 Description:  
%3  
10022 Storage Cell: %1 Unable to establish communication with controller, check all  
connections. Event Code: %2 Description: %3  
10023 Storage Cell: %1 Disk Group Data Lost Error Resolution Sequence 3 - Disk Group  
Resolved to Normal Event Code: %2 Description: %3  
10024 Storage Cell: %1 Disk Group Data Lost Error Resolution Sequence 1 - Marked Event  
Code: %2 Description: %3  
10025 Storage Cell: %1 Disk Group Data Lost Error Resolution Sequence 2 - Affected Units  
Deleted Event Code: %2 Description: %3  
10026 Storage Cell: %1 Disk Group Data Lost Error Resolution Sequence 3 - Disk Group  
Deleted Event Code: %2 Description: %3  
10027 Storage Cell: %1 Error - Creating the virtual disk would exceed the maximum allowable  
count Event Code: %2 Description: %3  
30028 8803754c  
30029 8803754d  
30030 8803754e  
30031 8803754f  
31001 88037919  
31002 8803791a  
31003 8803791b  
2
2
2
2
2
2
6
10028 Storage Cell: %1 Volume Insufficient Resources Event Code: %2 Description: %3  
10029 Storage Cell: %1 Process mutex is locked Event Code: %2 Description: %3  
10030 Storage Cell: %1 Invalid URL request type Event Code: %2 Description: %3  
10031 Storage Cell: %1 Invalid URL object type Event Code: %2 Description: %3  
11001 Storage Cell: %1 Agent Startup Complete Event Code: %2 Description: %3  
11002 Storage Cell: %1 AgentShutdown Complete Event Code: %2 Description: %3  
11003 Storage Cell: %1 Insufficient memory to create a new object, Heap may be full! Event  
Code: %2 Description: %3  
31004 8803791c  
32000 88037d00  
32001 88037d01  
6
2
2
11004 Storage Cell: %1 Agent Startup Failed Event Code: %2 Description: %3  
12000 Storage Cell: %1 Nsc Manager Interface First Status Event Code: %2 Description: %3  
12001 Storage Cell: %1 Nsc Manager Interface No NSCs Found Event Code: %2 Description:  
%3  
32002 88037d02  
2
12002 Storage Cell: %1 Nsc Manager Interface Index Out Of Range Event Code: %2  
Description: %3  
Storage Management Appliance Software Event Code Definitions Application Notes  
71  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
32003 88037d03  
32004 88037d04  
32005 88037d05  
32007 88037d07  
32008 88037d08  
2
2
2
2
2
12003 Storage Cell: %1 Unable to process command at this time. Retry the command or check  
all connections. Event Code: %2 Description: %3  
12004 Storage Cell: %1 Nsc Manager Interface Initialization Complete Event Code: %2  
Description: %3  
12005 Storage Cell: %1 Nsc Manager Interface Initialization Failed Event Code: %2  
Description: %3  
12007 Storage Cell: %1 Lock description not null but failed to get context ID Event Code: %2  
Description: %3  
12008 Storage Cell: %1 No Disk Groups Available For Access Event Code: %2 Description:  
%3  
33001 880380e9  
33002 880380ea  
33003 880380eb  
33004 880380ec  
33005 880380ed  
33006 880380ee  
33007 880380ef  
33008 880380f0  
33009 880380f1  
33010 880380f2  
33011 880380f3  
33012 880380f4  
2
2
2
2
6
2
6
6
6
2
3
2
13001 Storage Cell: %1 NM Good Status Event Code: %2 Description: %3  
13002 Storage Cell: %1 Notification Mngr Online Event Code: %2 Description: %3  
13003 Storage Cell: %1 Notification Mngr Offline Event Code: %2 Description: %3  
13004 Storage Cell: %1 NM Startup Complete Event Code: %2 Description: %3  
13005 Storage Cell: %1 NM Startup Failed Event Code: %2 Description: %3  
13006 Storage Cell: %1 Notification Succeeded Event Code: %2 Description: %3  
13007 Storage Cell: %1 Notification Failed Event Code: %2 Description: %3  
13008 Storage Cell: %1 Notification Failed - MLD Error Event Code: %2 Description: %3  
13009 Storage Cell: %1 Notification Failed - Network Error Event Code: %2 Description: %3  
13010 Storage Cell: %1 NM Shutdown Complete Event Code: %2 Description: %3  
13011 Storage Cell: %1 NM Shutdown Failed Event Code: %2 Description: %3  
13012 Storage Cell: %1 NM Prev Failed Notification Successfully Notified Event Code: %2  
Description: %3  
33013 880380f5  
33014 880380f6  
33015 880380f7  
33016 880380f8  
33017 880380f9  
34001 880384d1  
34002 880384d2  
34003 880384d3  
34004 880384d4  
34005 880384d5  
2
2
6
2
6
2
2
2
2
2
13013 Storage Cell: %1 NM SNMP Manager Online Event Code: %2 Description: %3  
13014 Storage Cell: %1 NM SNMP Packet Sent Event Code: %2 Description: %3  
13015 Storage Cell: %1 NM SNMP Packet Failed Event Code: %2 Description: %3  
13016 Storage Cell: %1 NM SNMP Manager Offline Event Code: %2 Description: %3  
13017 Storage Cell: %1 NM Memory Allocation Error Event Code: %2 Description: %3  
14001 Storage Cell: %1 View Already Exists Event Code: %2 Description: %3  
14002 Storage Cell: %1 View Is Not Set Event Code: %2 Description: %3  
14003 Storage Cell: %1 No View Object(s) Found Event Code: %2 Description: %3  
14004 Storage Cell: %1 View Index Is Out Of Range Event Code: %2 Description: %3  
14005 Storage Cell: %1 View Object - Invalid Object Condition Event Code: %2 Description:  
%3  
34006 880384d6  
34007 880384d7  
34008 880384d8  
34009 880384d9  
34010 880384da  
34011 880384db  
34012 880384dc  
34013 880384dd  
2
3
3
2
2
2
2
2
14006 Storage Cell: %1 View Object - Invalid Object Type Event Code: %2 Description: %3  
14007 Storage Cell: %1 View List Pointer is NULL Event Code: %2 Description: %3  
14008 Storage Cell: %1 View Object Pointer is NULL Event Code: %2 Description: %3  
14009 Storage Cell: %1 Building View List Object - Complete Event Code: %2 Description: %3  
14010 Storage Cell: %1 Building View List Object - Failed Event Code: %2 Description: %3  
14011 Storage Cell: %1 View Size is Zero Event Code: %2 Description: %3  
14012 Storage Cell: %1 View Find by UID Failed Event Code: %2 Description: %3  
14013 Storage Cell: %1 View Find by Type Failed Event Code: %2 Description: %3  
72  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
34014 880384de  
34015 880384df  
34016 880384e0  
34017 880384e1  
34018 880384e2  
35001 880388b9  
35002 880388ba  
35003 880388bb  
35004 880388bc  
35005 880388bd  
35006 880388be  
2
2
2
2
2
2
2
2
2
2
2
14014 Storage Cell: %1 View Find by Index Failed Event Code: %2 Description: %3  
14015 Storage Cell: %1 View Find by Name Failed Event Code: %2 Description: %3  
14016 Storage Cell: %1 View Find by WWN Failed Event Code: %2 Description: %3  
14017 Storage Cell: %1 View Find by Type by Name Failed Event Code: %2 Description: %3  
14018 Storage Cell: %1 View Find by Name by Type Failed Event Code: %2 Description: %3  
15001 Storage Cell: %1 Tree View Symbol Not Found Event Code: %2 Description: %3  
15002 Storage Cell: %1 Tree View Id Symbol Not Found Event Code: %2 Description: %3  
15003 Storage Cell: %1 Tree Cursor Symbol Not Found Event Code: %2 Description: %3  
15004 Storage Cell: %1 Tree Cursor Id Symbol Not Found Event Code: %2 Description: %3  
15005 Storage Cell: %1 Tree Sibling Symbol Not Found Event Code: %2 Description: %3  
15006 Storage Cell: %1 Tree Total Children Symbol Not Found Event Code: %2 Description:  
%3  
35007 880388bf  
35008 880388c0  
35009 880388c1  
36001 88038ca1  
2
2
2
2
15007 Storage Cell: %1 Tree Expansion Symbol Not Found Event Code: %2 Description: %3  
15008 Storage Cell: %1 Tree Contraction Symbol Not Found Event Code: %2 Description: %3  
15009 Storage Cell: %1 Tree Invalid Descriptor String Event Code: %2 Description: %3  
16001 Storage Cell: %1 Ema Short Status - Reissue Command Event Code: %2 Description:  
%3  
36002 88038ca2  
36003 88038ca3  
36004 88038ca4  
2
2
2
16002 Storage Cell: %1 Ema EMU Could Not Read ALPA Event Code: %2 Description: %3  
16003 Storage Cell: %1 Ema Invalid Request Event Code: %2 Description: %3  
16004 Storage Cell: %1 Ema Invalid Handle Set In Request Packet Event Code: %2  
Description: %3  
36005 88038ca5  
2
16005 Storage Cell: %1 Ema No Pstore At Referenced Location Event Code: %2 Description:  
%3  
36006 88038ca6  
36007 88038ca7  
2
2
16006 Storage Cell: %1 Ema No Primary EMU Selected Event Code: %2 Description: %3  
16007 Storage Cell: %1 Ema Invalid SubEnclosure ID Specified Event Code: %2 Description:  
%3  
36008 88038ca8  
36009 88038ca9  
2
2
16008 Storage Cell: %1 Ema No Device Found Event Code: %2 Description: %3  
16009 Storage Cell: %1 Ema Request Packet Missing Parameter Event Code: %2 Description:  
%3  
36010 88038caa  
36011 88038cab  
2
2
16010 Storage Cell: %1 Ema Could Not Find SubEnclosure in Configuration List Event Code:  
%2 Description: %3  
16011 Storage Cell: %1 Ema EMU Alarm Or Status Event Information Event Code: %2  
Description: %3  
36012 88038cac  
36013 88038cad  
2
2
16012 Storage Cell: %1 Ema Non-specific error occurred Event Code: %2 Description: %3  
16013 Storage Cell: %1 Ema Shelf WWN Could Not Be Accessed Through A Drive Event  
Code: %2 Description: %3  
36014 88038cae  
36015 88038caf  
36016 88038cb0  
2
2
2
16014 Storage Cell: %1 Ema EMU Failed To Enter Primary Mode Event Code: %2  
Description: %3  
16015 Storage Cell: %1 Ema EMU Failed To Exit Primary Mode Event Code: %2 Description:  
%3  
16016 Storage Cell: %1 Ema Downloaded File Does Not Contain Valid Fibre Channel Loader  
[status:1] Event Code: %2 Description: %3  
Storage Management Appliance Software Event Code Definitions Application Notes  
73  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
36017 88038cb1  
36018 88038cb2  
36019 88038cb3  
2
2
2
16017 Storage Cell: %1 Ema Downloaded File Format Is Not Recognized [status:2] Event  
Code: %2 Description: %3  
16018 Storage Cell: %1 Ema Incorrect Firmware In Downloaded File [status:3] Event Code: %2  
Description: %3  
16019 Storage Cell: %1 Ema Downloaded Loader is Too Large [status:4] Event Code: %2  
Description: %3  
36020 88038cb4  
36021 88038cb5  
2
2
16020 Storage Cell: %1 Ema Invalid Checksum [status:5] Event Code: %2 Description: %3  
16021 Storage Cell: %1 Ema Previous Offset Plus Previous Length Not Equal To Current Offset  
[status:6] Event Code: %2 Description: %3  
36022 88038cb6  
36023 88038cb7  
36024 88038cb8  
36025 88038cb9  
36026 88038cba  
36027 88038cbb  
36028 88038cbc  
36029 88038cbd  
36030 88038cbe  
36031 88038cbf  
36032 88038cc0  
36033 88038cc1  
36034 88038cc2  
36035 88038cc3  
36036 88038cc4  
36037 88038cc5  
36038 88038cc6  
36039 88038cc7  
2
2
2
2
2
2
2
2
2
2
2
6
2
2
2
2
2
2
16022 Storage Cell: %1 Ema Downloaded Loader Terminated Incorrectly [status:7] Event  
Code: %2 Description: %3  
16023 Storage Cell: %1 Ema EMU Out Of Memory [status:8] Event Code: %2 Description:  
%3  
16024 Storage Cell: %1 Ema EMU CDB Timeout -- Download Aborted [status:9] Event Code:  
%2 Description: %3  
16025 Storage Cell: %1 Ema EMU Internal State Machine Error [status:10] Event Code: %2  
Description: %3  
16026 Storage Cell: %1 Ema EMU Flash Erasure Failure [status:11] Event Code: %2  
Description: %3  
16027 Storage Cell: %1 Ema EMU In Primary Mode - Cannot Download To Primary EMU  
[status:12] Event Code: %2 Description: %3  
16028 Storage Cell: %1 Ema Previous Offset Plus Previous Length Greater Than Total Size  
[status:13] Event Code: %2 Description: %3  
16029 Storage Cell: %1 Ema Current Total Size Different From Previous Total Size [status:14]  
Event Code: %2 Description: %3  
16030 Storage Cell: %1 Ema Could Not Restore Reporting Group Number. Final Download  
Record Error Event Code: %2 Description: %3  
16031 Storage Cell: %1 Ema Could Not Recovery From Invop. Invop Retries Exhausted Event  
Code: %2 Description: %3  
16032 Storage Cell: %1 Ema Requested WWN Does Not Match Enclosure WWN Event  
Code: %2 Description: %3  
16033 Storage Cell: %1 Ema EMU Enclosure Services Error Occurred. EMU May Be  
Unavailable or Not Installed Event Code: %2 Description: %3  
16034 Storage Cell: %1 Ema SCSI Error Occurred While Trying To Communicate With EMU  
Event Code: %2 Description: %3  
16035 Storage Cell: %1 Ema Could Not Open EMU Firmware File Event Code: %2  
Description: %3  
16036 Storage Cell: %1 Ema EMU Firmware File Name Is Null Event Code: %2 Description:  
%3  
16037 Storage Cell: %1 Ema EMU Firmware Download Retries Exhausted. Manual Download  
May Be Required Event Code: %2 Description: %3  
16038 Storage Cell: %1 Ema EMU Current Firmware Version Matches Upgrade Firmware  
Version. No Upgrade Will Be Performed. Event Code: %2 Description: %3  
16039 Storage Cell: %1 Ema EMU Firmware Upgrade Success Event Code: %2 Description:  
%3  
74  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
36040 88038cc8  
2
2
2
2
2
2
2
6
3
3
16040 Storage Cell: %1 Ema EMU In Load State. Do Not Power Off. Reload EMU Firmware  
Event Code: %2 Description: %3  
37001 88039089  
17001 Storage Cell: %1 Drive Code Load Descriptor File Open Error Event Code: %2  
Description: %3  
37002  
37003  
8803908a  
8803908b  
17002 Storage Cell: %1 Drive Code Load Descriptor File Parsing Error - Invalid Line Event  
Code: %2 Description: %3  
17003 Storage Cell: %1 Drive Code Load Image File Open Error, Event Code: %2  
Description: %3  
37004 8803908c  
37005 8803908d  
37006 8803908e  
37007 8803908f  
37008 88039090  
37009 88039091  
17004 Storage Cell: %1 Drive Code Load Image File Error Getting File Size Event Code: %2  
Description: %3  
17005 Storage Cell: %1 Drive Code Load Image File Buffer Allocation Error Event Code: %2  
Description: %3  
17006 Storage Cell: %1 Drive Code Load Image File Read Error Event Code: %2 Description:  
%3  
17007 Storage Cell: %1 Drive Code Load Drive Firmware Update Failed Event Code: %2  
Description: %3  
17008 Storage Cell: %1 Drive Code Load Drive Inquiry Failed Event Code: %2 Description:  
%3  
17009 Storage Cell: %1 Drive Code Load Format Command Failed Event Code: %2  
Description: %3  
37010 88039092  
37011 88039093  
3
3
17010 Storage Cell: %1 Drive Code Load Format Failed Event Code: %2 Description: %3  
17011 Storage Cell: %1 Drive Code Load Restore Volume Failed Event Code: %2 Description:  
%3  
37012 88039094  
37013 88039095  
37014 88039096  
2
2
3
17012 Storage Cell: %1 Drive Code Load Get Physical Store Condition Failed Event Code: %2  
Description: %3  
17013 Storage Cell: %1 Drive Code Load Get Volume Condition Failed Event Code: %2  
Description: %3  
17014 Storage Cell: %1 Drive Code Load Drive Spin Up Error Event Code: %2 Description:  
%3  
37015 88039097  
37016 88039098  
2
2
17015 Storage Cell: %1 Drive Code Load - Complete Event Code: %2 Description: %3  
17016 Storage Cell: %1 Drive Code Load Disk Group Migration In Progress Event Code: %2  
Description: %3  
37017 88039099  
2
17017 Storage Cell: %1 Drive Code Load Unable To Code Load Disks Part Of A Group Event  
Code: %2 Description: %3  
38001 88039471  
38002 88039472  
38003 88039473  
38004 88039474  
38005 88039475  
38006 88039476  
38007 88039477  
38008 88039478  
38009 88039479  
38010 8803947a  
2
2
2
2
2
2
2
2
2
2
18001 Storage Cell: %1 Api Created Element Success Event Code: %2 Description: %3  
18002 Storage Cell: %1 Api Created Storage Success Event Code: %2 Description: %3  
18003 Storage Cell: %1 Api Created Storage Client Success Event Code: %2 Description: %3  
18004 Storage Cell: %1 Api Set Storage Success Event Code: %2 Description: %3  
18005 Storage Cell: %1 Api Set Element Success Event Code: %2 Description: %3  
18006 Storage Cell: %1 Api Deleted Element Success Event Code: %2 Description: %3  
18007 Storage Cell: %1 Api Deleted Storage Success Event Code: %2 Description: %3  
18008 Storage Cell: %1 Api Deleted Storage Client Success Event Code: %2 Description: %3  
18009 Storage Cell: %1 Api Created Snapshot Success  
18010 Storage Cell: %1 Api Created Clone Success Event Code: %2 Description: %3  
Storage Management Appliance Software Event Code Definitions Application Notes  
75  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
38018 88039482  
38019 88039483  
38022 88039486  
38024 88039488  
38025 88039489  
38028 8803948c  
38034 88039492  
2
2
2
2
2
2
2
18018 Storage Cell: %1 Api Unable To Get The Lock Event Code: %2 Description: %3  
18019 Storage Cell: %1 Api Created PresentedUnit Success Event Code: %2 Description: %3  
18022 Storage Cell: %1 Api Create DiskGroup Success Event Code: %2 Description: %3  
18024 Storage Cell: %1 Api Create Folder Success Event Code: %2 Description: %3  
18025 Storage Cell: %1 Api Delete Folder Success Event Code: %2 Description: %3  
18028 Storage Cell: %1 Api Set Folder Success Event Code: %2 Description: %3  
18034 Storage Cell: %1 Api Invalid User Name Or Password Error Event Code: %2  
Description: %3  
38036 88039494  
38038 88039496  
2
2
18036 Storage Cell: %1 Api Delete Presented Unit Success Event Code: %2 Description: %3  
18038 Storage Cell: %1 Api Set Diskgroup Success  
Description: %3  
Event Code: %2  
38039 88039497  
38040 88039498  
38041 88039499  
38042 8803949a  
2
2
2
2
18039 Storage Cell: %1 Api Set Disk Success Event Code: %2 Description: %3  
18040 Storage Cell: %1 Api Delete Storage Family Success Event Code: %2 Description: %3  
18041 Storage Cell: %1 Api Set Storage Family Success Event Code: %2 Description: %3  
18042 Storage Cell: %1 Api Control Memory Allocation Failure Event Code: %2 Description:  
%3  
38045 8803949d  
38047 8803949f  
38048 880394a0  
38049 880394a1  
38050 880394a2  
38051 880394a3  
38052 880394a4  
38059 880394ab  
38060 880394ac  
38063 880394af  
2
2
2
2
2
2
2
2
2
2
18045 Storage Cell: %1 Api Element Codeload Success  
Event Code: %2 Description: %3  
18047 Storage Cell: %1 Api Disk Codeload Success Event Code: %2 Description: %3  
18048 Storage Cell: %1 Api Monitor Codeload Success Event Code: %2 Description: %3  
18049 Storage Cell: %1 Api Added Port WwID Success Event Code: %2 Description: %3  
18050 Storage Cell: %1 Api Set Storage Client Success Event Code: %2 Description: %3  
18051 Storage Cell: %1 Api Invalid Operation Event Code: %2 Description: %3  
18052 Storage Cell: %1 Api Deleted Port WwID Success Event Code: %2 Description: %3  
18059 Storage Cell: %1 Api Set Power Success Event Code: %2 Description: %3  
18060 Storage Cell: %1 Api Element Is Not Initialized Event Code: %2 Description: %3  
18063 Storage Cell: %1 Api Error trying to delete a disk group Event Code: %2 Description:  
%3  
38065 880394b1  
38066 880394b2  
38067 880394b3  
38068 880394b4  
2
2
2
2
2
2
2
2
18065 Storage Cell: %1 Api A storage (virtual disk) operation is in progress. Try again later.  
Event Code: %2 Description: %3  
18066 Storage Cell: %1 Api The storage (virtual disk) condition is invalid. The storage may be  
in error. Try again later. Event Code: %2 Description: %3  
18067 Storage Cell: %1 Api Error calling get virtual disk condition. Virtual disk may be deleted.  
Try again later. Event Code: %2 Description: %3  
18068 Storage Cell: %1 Api Invalid initialization of the API. Cannot start monitoring process  
which limits storage cell actions. Event Code: %2 Description: %3  
38070  
880394b6  
18070 Storage Cell: %1 Api A command is currently under execution from another API call. Try  
again later. Event Code: %2 Description: %3  
38071 880394b7  
18071 Storage Cell: %1 Api The server has not completed initialization, cannot process the  
request. Event Code: %2 Description: %3  
38073  
38074  
880394b9  
880394ba  
18073 Storage Cell: %1 Api Removing of disk from disk group successfull Event Code: %2  
Description: %3  
18074 Storage Cell: %1 Api Adding of disk(s) to disk group successfull Event Code: %2  
Description: %3  
76  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
38075  
880394bb  
2
2
2
18075 Storage Cell: %1 Api Modify monitor properties successfull Event Code: %2  
Description: %3  
38076  
880394bc  
18076 Storage Cell: %1 Api Element name too long. Maximum is 20 characters. Event Code:  
%2 Description: %3  
38079 880394bf  
38080 880394c0  
38081 880394c1  
38082 880394c2  
18079 Storage Cell: %1 Api The basic license cannot be validated. Either the license key has  
not been entered, or there is a system communication failure. Event Code: %2  
Description: %3  
2
2
2
18080 Storage Cell: %1 Api The snapshot/Snapclone license cannot be validated. Either the  
license key has not been entered, or there is a system communication failure. Event  
Code: %2 Description: %3  
18081 Storage Cell: %1 Api The folder operation is not valid for the specified folder. Either the  
folder is a root folder and cannot be modified, or it is a disk group folder for which you  
should use ‘set group’ command. Event Code: %2 Description: %3  
18082 Storage Cell: %1 Api Cannot create the clone copy because the target storage is not  
presented. Event Code: %2 Description: %3  
39001 88039859  
39002 8803985a  
39003 8803985b  
3
2
2
19001 Storage Cell: %1 Storage Cell Lock Error Event Code: %2 Description: %3  
19002 Storage Cell: %1 Storage Cell Deleted Event Code: %2 Description: %3  
19003 Storage Cell: %1 An outstanding command is in-progress for the selected storage  
system. Please try again later. Event Code: %2 Description: %3  
39004 8803985c  
39005 8803985d  
39006 8803985e  
39007 8803985f  
39008 88039860  
39009 88039861  
39010 88039862  
2
2
2
2
3
3
6
19004 Storage Cell: %1 Lock Wait Time too large Event Code: %2 Description: %3  
19005 Storage Cell: %1 Place Request In Q Failed Event Code: %2 Description: %3  
19006 Storage Cell: %1 No Match for Q Found Event Code: %2 Description: %3  
19007 Storage Cell: %1 Agent Wait Timeout Event Code: %2 Description: %3  
19008 Storage Cell: %1 Free Lock Unsuccessful Event Code: %2 Description: %3  
19009 Storage Cell: %1 Lock Manager Mutex Timeout Error Event Code: %2 Description: %3  
19010 Storage Cell: %1 Lock Queue Memory Allocation Failure Event Code: %2 Description:  
%3  
40001 88039c41  
40002 88039c42  
40003 88039c43  
40004 88039c44  
40005 88039c45  
40011 88039c4b  
40012 88039c4c  
6
2
6
2
3
3
3
20001 Storage Cell: %1 LicMngr Memory Allocation Failure Event Code: %2 Description: %3  
20002 Storage Cell: %1 LicMngr Startup Complete Event Code: %2 Description: %3  
20003 Storage Cell: %1 LicMngr Startup Failed Event Code: %2 Description: %3  
20004 Storage Cell: %1 License successfully checked out Event Code: %2 Description: %3  
20005 Storage Cell: %1 License checkout failed Event Code: %2 Description: %3  
20011 Storage Cell: %1 License Line has an incorrect format Event Code: %2 Description: %3  
20012 Storage Cell: %1 License file with this Node WWID is missing Event Code: %2  
Description: %3  
40013 88039c4d  
40014 88039c4e  
40015 88039c4f  
6
6
3
20013 Storage Cell: %1 License Library runtime error Event Code: %2 Description: %3  
20014 Storage Cell: %1 New License Job invocation failed Event Code: %2 Description: %3  
20015 Storage Cell: %1 Failed to retrieve Node WWN from storage system Event Code: %2  
Description: %3  
40016 88039c50  
3
20016 Storage Cell: %1 Failed to retrieve license list from MLD Event Code: %2 Description:  
%3  
40017 88039c51  
40018 88039c52  
3
3
20017 Storage Cell: %1 Failed to write license list to MLD Event Code: %2 Description: %3  
20018 Storage Cell: %1 This license line appears to be invalid Event Code: %2 Description:  
%3  
Storage Management Appliance Software Event Code Definitions Application Notes  
77  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
40019 88039c53  
40020 88039c54  
40021 88039c55  
40022 88039c56  
40023 88039c57  
41001 8803a029  
41002 8803a02a  
41003 8803a02b  
41004 8803a02c  
41005 8803a02d  
41006 8803a02e  
41007 8803a02f  
41008 8803a030  
41009 8803a031  
41010 8803a032  
41011 8803a033  
41012 8803a034  
41013 8803a035  
41014 8803a036  
41015 8803a037  
41016 8803a038  
41017 8803a039  
42001 8803a411  
3
6
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
20019 Storage Cell: %1 MLD Manager Handle is NULL - unable to update MLD License List  
Event Code: %2 Description: %3  
20020 Storage Cell: %1 LicMngr: StorageCell Handle is NULL Event Code: %2 Description:  
%3  
20021 Storage Cell: %1 The license you entered is a valid license but not for the Node WWN  
on this controller pair Event Code: %2 Description: %3  
20022 Storage Cell: %1 Function name string is null or in an incorrect format Event Code: %2  
Description: %3  
20023 Storage Cell: %1 Version string is null or in an incorrect format Event Code: %2  
Description: %3  
21001 Storage Cell: %1 HSV Upgrade Manager Image File Open Error Event Code: %2  
Description: %3  
21002 Storage Cell: %1 HSV Upgrade Manager Image File Buffer Allocation Error Event  
Code: %2 Description: %3  
21003 Storage Cell: %1 HSV Upgrade Manager Image File Read Error Event Code: %2  
Description: %3  
21004 Storage Cell: %1 HSV Upgrade Manager Event File Write Error Event Code: %2  
Description: %3  
21005 Storage Cell: %1 HSV Upgrade Manager Drive Firmware Update Failed Event Code:  
%2 Description: %3  
21006 Storage Cell: %1 HSV Upgrade Manager Global Header Edc Compute Error Event  
Code: %2 Description: %3  
21007 Storage Cell: %1 HSV Upgrade Manager Image Header Edc Compute Error Event  
Code: %2 Description: %3  
21008 Storage Cell: %1 HSV Upgrade Manager Image Type Exceeds Max Image Count Event  
Code: %2 Description: %3  
21009 Storage Cell: %1 HSV Upgrade Manager Image Type Not Controller Image Event  
Code: %2 Description: %3  
21010 Storage Cell: %1 HSV Upgrade Manager Image Size Exceeded Event Code: %2  
Description: %3  
21011 Storage Cell: %1 HSV Upgrade Manager Event File Open Error Event Code: %2  
Description: %3  
21012 Storage Cell: %1 HSV Upgrade Manager Image Edc Compute Error Event Code: %2  
Description: %3  
21013 Storage Cell: %1 HSV Upgrade Manager Begin Text Not Found Event Code: %2  
Description: %3  
21014 Storage Cell: %1 HSV Upgrade Manager After Text Not Found Event Code: %2  
Description: %3  
21015 Storage Cell: %1 HSV Upgrade Manager File Format Version Mismatch Event Code:  
%2 Description: %3  
21016 Storage Cell: %1 HSV Upgrade Manager Global Header Format Version Mismatch  
Event Code: %2 Description: %3  
21017 Storage Cell: %1 HSV Upgrade Manager Product Information Was Not Found Event  
Code: %2 Description: %3  
22001 Storage Cell: %1 Trace: Unable to write managment agent trace file Event Code: %2  
Description: %3  
78  
Storage Management Appliance Software Event Code Definitions Application Notes  
HSV Element Manager Event Codes  
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)  
Event  
ID  
Event  
Code  
Sev-  
erity  
Evt.  
No.  
Description  
42002 8803a412  
43002 8803a7fa  
43003 8803a7fb  
2
3
6
22002 Storage Cell: %1 Trace: file write succeeded Event Code: %2 Description: %3  
23002 Storage Cell: %1 Diagnostic The view list has errors Event Code: %2 Description: %3  
23003 Storage Cell: %1 Diagnostic Memory allocation failure Event Code: %2 Description:  
%3  
Storage Management Appliance Software Event Code Definitions Application Notes  
79  
HSV Element Manager Event Codes  
80  
Storage Management Appliance Software Event Code Definitions Application Notes  

National Instruments USB device 625x User Manual
Morphy Richards 29003 User Manual
Miele CVA 615 User Manual
Maxtor One Touch STM307504OTB3E5 RK User Manual
M Audio Computer Drive User Manual
La Crosse Technology WT 5721 User Manual
Grindmaster P300E User Manual
Bunn Coffeemaker VPR APS User Manual
Briel DOMUS ES161AMG TB User Manual
Black &amp; Decker DE40 User Manual