Fetco Home Decor Coffeemaker CBS 2052E User Manual

User’s Guide  
Models:  
f
f
f
CBS-2051e  
CBS-2052e  
CBS-2052e20  
NOTICE TO INSTALLER: Please leave this book with the machine.  
Table of Contents  
Contact Information ..................................................2  
Programming..........................................................10  
Batch Settings.....................................................10  
Temperature Settings .........................................11  
Advanced Settings and Diagnostics ...................11  
Relay Test...........................................................12  
Error Codes ............................................................13  
Parts .......................................................................14  
Description & Features.............................................2  
Specifications............................................................2  
Requirements........................................................2  
Weights and Capacities ........................................2  
Electrical Configuration and Brewing Efficiency ...3  
Dimensions & Utility Connections.............................4  
Installation.................................................................6  
Operating Instructions ..............................................9  
FETCO®, LUXUS®, EXTRACTOR® and Driven To Pioneer Innovation™ are trademarks or trade names of Food Equipment Technologies Company.  
© 2005 Food Equipment Technologies Company Part # P021 October 20, 2005  
Electrical Configuration and Brewing Efficiency  
US & Canada  
CBS-2051e  
1.5 gallons per batch  
Batches per Hour* (max 11)  
Electrical  
Heater  
Configuration  
Voltage  
(AC)  
Maximum  
Amp draw  
Config. Code  
Phase  
Wires  
KW  
4.6  
5.1  
6.1  
Cold Water  
Hot Water  
E51016  
2 X 3 KW  
120/208  
120/220  
120/240  
22.1  
23.4  
25.5  
7.7  
11.0  
single  
3 + ground  
8.6  
11.0  
10.3  
11.0  
CBS-2052e  
1.5 gallons per batch  
Batches per Hour* (max 22)  
Electrical  
Heater  
Configuration  
Voltage  
(AC)  
Maximum  
Amp draw  
Config. Code  
Phase  
Wires  
KW  
4.6  
5.1  
6.1  
Cold Water  
Hot Water  
E52016  
Universal  
Wiring  
Option 1  
2 X 3 KW  
(Factory Setting)  
120/208  
120/220  
120/240  
22.4  
23.7  
25.8  
7.7  
18.6  
single  
3 + ground  
8.6  
20.8  
10.3  
22.0  
Option 2  
3 X 3 KW  
120/208  
120/220  
120/240  
6.9  
7.7  
9.1  
19.5  
20.6  
22.5  
11.5  
12.9  
15.4  
22.0  
22.0  
22.0  
Total 3 X 3 KW  
Heaters  
three  
4 + ground  
3 + ground  
E52026  
Universal  
Wiring  
Option 1  
2 X 5 KW  
120/208  
120/220  
120/240  
7.6  
8.5  
10.1  
36.9  
39.0  
42.5  
12.8  
14.4  
17.1  
22.0  
22.0  
22.0  
single  
three  
Option 2  
3 X 5 KW  
(Factory Setting)  
120/208  
120/220  
120/240  
11.4  
32.0  
33.9  
36.9  
19.2  
22.0  
22.0  
22.0  
22.0  
22.0  
Total 3 X 5 KW  
Heaters  
4 + ground 12.7  
15.1  
CBS-2052e20  
2.0 gallons per batch  
Batches per Hour* (max 18)  
Electrical  
Heater  
Configuration  
Voltage  
(AC)  
Maximum  
Amp draw  
Config. Code  
Phase  
Wires  
KW  
4.6  
5.1  
6.1  
Cold Water  
Hot Water  
E53016  
Universal  
Wiring  
Option 1  
2 X 3 KW  
(Factory Setting)  
120/208  
120/220  
120/240  
22.4  
23.7  
25.8  
5.8  
14.0  
single  
3 + ground  
6.5  
15.6  
7.7  
18.0  
Option 2  
3 X 3 KW  
120/208  
120/220  
120/240  
6.9  
7.7  
9.1  
19.5  
20.6  
22.5  
8.6  
10.1  
11.6  
18.0  
18.0  
18.0  
Total 3 X 3 KW  
Heaters  
three  
4 + ground  
3 + ground  
E53026  
Universal  
Wiring  
Option 1  
2 X 5 KW  
120/208  
120/220  
120/240  
7.6  
8.5  
10.1  
36.9  
39.0  
42.5  
9.6  
11.2  
12.8  
18.0  
18.0  
18.0  
single  
three  
Option 2  
3 X 5 KW  
(Factory Setting)  
120/208  
120/220  
120/240  
11.4  
32.0  
33.9  
36.9  
14.4  
16.5  
16.5  
18.0  
18.0  
18.0  
Total 3 X 5 KW  
Heaters  
4 + ground 12.7  
15.1  
* Based on standard factory settings: 4.0 minute brew time; 0% prewet, 0% bypass; 200 F water.  
Export  
CBS-2051e  
1.5 gallons per batch  
Batches per Hour* (max 11)  
Electrical  
Heater  
Configuration  
Voltage  
(AC)  
Maximum  
Amp draw  
Config. Code  
Phase  
Wires  
KW  
Cold Water  
Hot Water  
E51026  
2 X 3 KW  
220  
single  
2 + ground  
5.1  
23.4  
8.9  
11.0  
CBS-2052e  
1.5 gallons per batch  
Batches per Hour* (max 22)  
Electrical  
Heater  
Configuration  
Voltage  
(AC)  
Maximum  
Amp draw  
Config. Code  
Phase  
Wires  
KW  
Cold Water  
Hot Water  
E52036  
2 X 3 KW  
220  
single  
2 + ground  
5.1  
23.7  
8.6  
20.8  
CBS-2052e20  
2.0 gallons per batch  
Batches per Hour* (max 18)  
Electrical  
Heater  
Configuration  
Voltage  
(AC)  
Maximum  
Amp draw  
Config. Code  
Phase  
Wires  
KW  
Cold Water  
Hot Water  
E53036  
2 X 3 KW  
220  
single  
2 + ground  
5.1  
23.7  
6.5  
15.6  
* Based on standard factory settings: 4.0 minute brew time; 0% prewet, 0% bypass; 200 F water.  
3
Dimensions & Utility Connections  
CBS-2051e  
DWG 201100-000  
CBS-2052e  
DWG 201101-000  
4
CBS-2052e20  
DWG 201129-000  
5
Installation  
(For Qualified Service Technicians Only)  
Keys To A Successful Installation  
If not installed correctly by qualified personnel, the brewer may not operate properly and damage may result.  
Damages resulting from improper installation are not covered by the warranty.  
Here are the key points to consider before installation:  
Electrical:  
All FETCO brewers require NEUTRAL. Ground is not an acceptable substitute. Installation without neutral  
may cause damage to the electronic components.  
Universal wiring: This brewer can be configured for single or three phase operation. Conversion  
instructions are described later in this section.  
The electrical diagram and universal wiring instructions are located on the inside of the lower cover.  
The installation must comply with applicable federal, state, and local codes having jurisdiction at your  
location. Check with your local inspectors to determine what codes will apply.  
Plumbing:  
This equipment is to be installed to comply with the applicable federal, state, or local plumbing codes.  
The water line must be flushed thoroughly prior to connecting it to the brewer to prevent debris from  
contaminating the machine.  
Verify that the water line will provide at least 1 gallon per minute for the CBS-2051e, and 1.5 gallons per  
minute for the CBS-2052e and 2052e20 before connecting it to the brewer.  
General:  
Utilize only qualified beverage equipment service technicians for installation. A Service Company Directory  
may be found on our web site, http://www.fetco.com.  
Installation Instructions  
Brewer Setup  
1. Review the Dimensions for the unit you are installing. Verify that the brewer will fit in the space intended for it,  
and that the counter or table will support the total weight of the brewer and dispensers when filled.  
2. The brewer’s legs are shipped inside the brew baskets.  
Warning: Legs are to be adjusted for  
leveling the brewer only. Do not use  
for height adjustment or extend them  
higher than necessary.  
Remove the brew basket(s) and the coffee dispenser(s).  
Place the brewer on its back and screw in the legs.  
3. Place the brewer on the counter or stand.  
4. When the brewer is in position, level it front to back as well  
as side to side by adjusting the legs.  
5. Remove the lower cover to access the water and electrical connections. Knock-outs are provided in the back  
and base of the brewer body for the connections.  
Water Connection  
1. Water inlet is a 3/8 inch male flare fitting.  
2. The brewer can be connected to a cold or hot water line. Cold water is preferred for best coffee flavor, but hot  
water will allow for faster recovery times.  
3. Install a water shut off valve near the brewer to facilitate service. If an in-line water filter is used, it should be  
installed after the water shut off valve and in a position to facilitate filter replacement.  
4. Flush the water supply line and filter before connecting it to the brewer.  
5. Verify that the water line will provide at least 1 gallon per minute for the CBS-2051e, and 1.5 gallons per minute  
for the CBS-2052e and 2052e20, and that the water pressure is between 20 and 75 psig.  
6. Use a wrench on the factory fitting when connecting the incoming water line. This will reduce stress on the  
internal connections and reduce the possibility of leaks developing after the install has been completed.  
6
Electrical Connection  
1. Verify that the actual voltage at the electrical service connection is compatible with the specifications on the  
brewer’s serial number label. Make sure the electrical service includes neutral.  
2. The temperature and water tank fill level are pre-set at the factory. There is no need to turn off the heaters  
during the installation process. The heaters are disabled by the control board until the tank is full of water. The  
heating process will start automatically when the tank has filled.  
3. A terminal block is provided for connecting the incoming power wires. Consult local codes to determine if a  
cord and plug can be installed, or if the unit must be hard wired.  
4. A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near the  
brewer, and its location and markings known to the operators.  
Warning: To prevent  
electrical shock, this  
unit must be properly  
grounded.  
5. The body of the brewer must be grounded to a suitable building ground.  
A ground lug is provided in the brewer next to the power terminal block.  
Use only 10 gauge copper wire for grounding.  
6. Electrical connections must be secured in-place within the unit to meet  
national and local standards.  
7. Connect the incoming power wires to the terminal block in accordance with applicable codes.  
CBS-2051e  
GROUND LUG  
L1  
N
L2  
120V  
120V  
N
GROUND  
WIRE  
208-240V  
The CBS-2052e and CBS-2052e20 are shipped from the factory configured for either single phase or three  
phase operation, depending on the version that was ordered. A tag attached to the terminal block will indicate  
which way the unit was configured.  
Notice: The following conversion should be performed only by a qualified beverage equipment  
service technician or electrician.  
For brewers manufactured before August, 2005:  
To change the configuration, arrange the heater wires as shown below. Make sure that all connections are  
tight. These instructions are also located on the inside of the lower cover.  
HEATER WIRES  
HEATER WIRES  
CBS-2052e  
CBS-2052e  
THREE PHASE  
CONFIGURATION  
SINGLE PHASE  
CONFIGURATION  
1 & 2 3 & 4 5 & 6  
4 & 5  
1 & 2  
3 & 6  
120/208-240 VAC  
3 wires + ground  
120/208-240 VAC  
4 wires + ground  
N
L1 L2 L3  
N
L1 L2 L3  
GROUND  
LUG  
GROUND  
LUG  
NOT  
USED  
208-240V  
208-240V  
208-240V  
120V  
120V  
GROUND  
WIRE  
GROUND  
WIRE  
208-240V  
N
N
Incoming Power: Connect wires to L1, L2, N, Ground  
Incoming Power: Connect wires to L1, L2, L3, N, Grnd  
Heater Wires:  
Connect wires 1 & 2 to L1  
Connect wires 4 & 5 to L2  
Connect wires 3 & 6 to L3  
Heater Wires:  
Connect wires 1 & 2 to L1  
Connect wires 3 & 4 to L2  
Connect wires 5 & 6 to L3  
For brewers manufactured after August 1, 2005:  
A jumper wire with instruction tag is provided (pictured at right).  
Single Phase: Connect the jumper to L2 and L3.  
Connect incoming wires to L1, L2, N, ground.  
Three Phase: Do not use the jumper.  
Connect wires to L1, L2, L3, N, ground.  
When not used, the jumper should remain secured inside the  
brewer for future use.  
7
Final Setup  
1. Turn on the incoming water supply line and inspect both inside and  
outside of the brewer for leaks in all fittings and tubes  
2. Turn on the incoming power.  
3. Press the brewer’s main power switch, which is hidden behind the  
front leg of the brewer. The control panel on/off switch will begin  
flashing. Press this switch.  
4. Within 6 seconds, the hot water tank will begin filling until the water is  
sensed by the probe at the top of the tank. The display will read  
“FIL”. The heaters will be disabled by the control board until the tank  
is full.  
5. While the water is heating, the display will read “LO” and the actual  
water temperature will be displayed. After the water has reached the  
set temperature, the display will be blank. There is no “ready” light.  
6. Review the Operating Instructions. Brew one full batch (water only)  
on each side to confirm proper fill levels. The brewer is factory set  
with water only (no coffee) to dispense the correct amount of water.  
If the actual volume is slightly different from the programmed volume,  
fine tuning the brewer may be necessary. See #60 – 63 in the  
Advanced Settings & Diagnostics section.  
7. Re-attach the covers after one final inspection for leaks. Look  
closely in the top of the brewer at the dispense fittings during this  
inspection.  
Operator Training  
Review the operating procedures with whoever will be using the brewer.  
Pay particular attention to the following areas:  
1. Always pre-heat the dispensers before the first use of each day by  
filling them half way with hot water, and letting them stand for at least  
15 minutes.  
2. Don't remove the brew basket until it has stopped dripping.  
3. Make sure the dispenser is empty before brewing into it.  
4. Show how to attach covers, close, and or secure the thermal  
dispensers for transporting.  
5. Show the location and operation of the water shut off valve as well as  
the circuit breaker for the brewer.  
6. Steam from the tank will form condensation in the vent tubes. This  
condensation will drip into and then out of the brew baskets. 1/4 cup  
discharging overnight is possible. Place an appropriate container  
under each brew basket when not in use.  
7. We recommend leaving the power to the brewer on overnight. The  
water tank is well insulated and will use very little electricity to keep  
the tank hot. Leaving the brewer in the on position will also avoid  
delays at the beginning of shifts for the brewer to reach operating  
temperature.  
8
Operating Instructions  
Control Panel Functions  
Only switches that are active are illuminated.  
Switches that are inactive or disabled are invisible.  
X Main Power Switch  
Controls all power to brewer  
Indicator lamp at top of panel.  
Y Control Panel On/Off Switch  
Secondary power switch. Does not  
disconnect main power.  
Flashing = Off  
Lit = On  
Invisible = Main Power Off  
Z Display  
”FIL” = Water tank is filling.  
”LO XXX” = Unit is heating, not  
ready to brew. (XXX = actual  
temperature)  
”NO BAS” = Brew basket not in  
position.  
Blank = Ready to brew.  
Also displays error messages.  
[ Stop Switches  
Stops brew cycle  
Lit = Brew cycle in progress  
Invisible = Not brewing, or dripping  
in progress  
\ Brew Switches  
Starts brew cycle  
Must be held in for 1 second  
Flashing = Brew cycle in progress  
Lit = Ready to brew  
Invisible – Not ready to brew, or  
batch disabled  
(See Programming Section)  
] Hot Water Switch  
Dispenses hot water from faucet  
Hold in to dispense  
Brewing  
1. Turn the main power switch and control  
panel switch on.  
7. When the brew cycle is finished, the STOP  
button will extinguish and the BREW button will  
continue flashing, indicating that coffee may still  
be dripping from the bottom of the brew basket.  
8. Before removing the brew basket or dispenser,  
visually verify that dripping has stopped.  
Notes:  
2. Prepare a brew basket with the correct size  
filter and appropriate amount of coffee.  
3. Slide the brew basket completely into the  
rails.  
4. Place a clean, empty, preheated dispenser  
under the brew basket.  
5. Select a batch from the available choices,  
and hold the corresponding BREW button in  
for 1 second to start the brew cycle.  
6. The STOP button will illuminate, and the  
selected BREW button will flash, indicating  
that brewing is in progress. All other BREW  
buttons will extinguish.  
Preheat dispenser by filling at least ½ full with  
water at brewing temperature. Allow it to sit for  
at least 15 minutes before draining.  
A sensor will prevent the brewer from operating  
if the brew basket is not all the way in.  
A brew basket lock will prevent removal of the  
brew basket during brewing and dripping  
9
Programming  
Display  
Batch Settings  
Turn the brewer off by pressing the main power switch.  
Press the main power switch again to turn the unit on.  
52  
The last 2 digits of the model number will display briefly, then S t b.  
S t b  
Quickly hold the STOP button for 3 seconds.  
The display will show the software version. Example:  
Press STOP to continue.  
P r G  
0.0 4.8  
Batches are numbered 1 – 3 (CBS-2051e) or 1 – 6 (CBS-2052e / 2052e20)  
PARAMETER  
BATCH #  
SETTING  
1.1 1.50  
Example:  
Left Side – Large Batch – Volume 1.5 Gal.  
Next, the first batch parameter is displayed – batch 1, brew volume  
Use the SCROLL UP and SCROLL DOWN buttons to adjust.  
Press the STOP button to go to the next parameter – brew time.  
1.1 1.50  
1.2 4.00  
Continue this way until all parameters are programmed for batch #1.  
(See the chart below for an explanation of each parameter.)  
Next, batch #2 programming begins.  
2.0 OFF  
Batches 2, 3, 5, and 6 may be disabled by leaving them set to “OFF”.  
Change to “ON” to enable. Batches 1 and 4 cannot be disabled.  
After all batches are programmed, go to temperature settings.  
7
200  
(See next page)  
Important! After programming, you must press the HOT WATER button to save the settings and exit  
programming mode, or changes will be lost. You may exit programming at any time.  
Batch Parameters  
X=Batch Number (1 - 6)  
Parameter  
Name  
Range  
Increment  
Default Setting  
Comment  
X.0  
Batch Enabled or  
Disabled  
On/Off  
Batch 1 & 4 = ON  
Batch 2, 3, 5, 6 = OFF be disabled.  
Batch 1 & 4 cannot  
X.1  
Brew Volume  
(Gallons)  
0.25 – 3.00  
0.01  
1.5 gal. (2051e/2052e) To display liters, see  
2.0 gal. (2052e20)  
# 59 in Advanced  
Settings section.  
X.2  
X.3  
Brew Time (Min:Sec) 2:00 – 24:00  
0:30  
1%  
4:00 minutes  
0 %  
Bypass Percent  
0.00 – 40.0%  
0.00 – 15.0%  
0:10 – 5:00  
Percentage of total  
brew volume  
Percentage of total  
brew volume  
The time between  
prewetting and start  
of brew cycle.  
X.4  
X.5  
Prewet Percent  
1%  
0 %  
Prewet Delay  
(Min:Sec)  
0:10  
1:00 minute  
X.6  
Drip Delay (Min:Sec) 0:30 – 6:00  
Minutes  
0:10  
1:30 minute  
The time between  
end of brew cycle  
and unlocking of  
brew basket.  
10  
Temperature Settings  
Parameter  
Name  
Range  
Default Setting  
Comment  
7
Inside tank. Will be slightly lower at  
spray head. To display in ° Celsius,  
see # 58 in Advanced Settings.  
A= Faucet will dispense only when not  
brewing.  
On=Faucet always enabled.  
Off=Faucet always disabled.  
0=Will brew at any temperature  
above 180°F.  
Water Temp. (°F)  
180°F - 208°F  
200°F  
8
9
Hot Water Service  
A (auto) / On / Off  
A (auto)  
1
Brew at Set  
Temperature  
0 - 1  
1=Will brew only at set temperature.  
Note: Changes will not take effect  
until one full brew cycle is  
completed after the change is  
made.  
Parameter  
Name  
Range  
Default Setting  
Comment  
10  
Enter Advanced  
Settings &  
Diagnostics  
0 - 1  
0
0 = Skip Advanced Settings &  
Diagnostics. Loop back to start of  
batch programming cycle.  
1 = Enter Advanced Settings &  
Diagnostics.  
Press STOP to continue  
Important! To save your changes, press  
to exit programming mode and return to operating mode.  
Advanced Settings and Diagnostics  
Address  
Description  
Water Level  
in Tank  
Range  
Default  
Comment  
50  
0 - 1  
Tests if water is touching probe.  
0 = Tank is less than full  
1 = Tank is full  
52  
Brew Basket  
Sensor State  
(left / right)  
Tank Temperature  
Brewer Model  
Number  
0 - 1  
To test, slide the brew basket in and out. Display  
should toggle between 0 and 1.  
0 = Brew basket out. 1 = Brew Basket in.  
Displays current tank temperature.  
Must be set for the correct model number of the  
brewer: 51 for CBS-2051e,  
55  
56  
180°F - 208°F  
31 - 52  
52 for CBS-2052e and CBS-2052e20.  
Changes all settings to default factory settings.  
0 = Do not reload defaults  
57  
Reload Defaults  
0 - 1  
0
1 = Reload all default settings  
If 1 is selected, you must advance to the next  
address for this change to take effect.  
Does not change address 56 – model number.  
F = Displays temp in degrees Fahrenheit  
C = Displays temp in degrees Celsius  
GAL = Displays volume in gallons  
LTR = Displays volume in liters  
58  
59  
Temperature Scale F or C  
F
Water Volume  
Scale  
GAL or LTR  
GAL  
11  
Address  
60  
and  
61  
Description  
Range  
Default  
Comment  
Left Brew Valve  
Flow Rate  
Right Brew Valve  
Flow Rate  
0.09 – 1.49  
If #59 is GAL  
0.92  
Use this to compensate for minor discrepancies in  
actual volume versus programmed volume. Set  
lower to increase volume, higher to decrease  
volume. The following formula can be used to  
determine the correct setting:  
or  
0.33 – 5.63  
If #59 is LTR  
0.28 – 0.38  
If #59 is GAL  
3.48  
0.33  
62  
and  
63  
Left Bypass Valve  
Flow Rate  
Right Bypass  
Valve Flow Rate  
ACTUAL VOLUME  
CURRENT  
SETTING  
NEW  
SETTING  
X
=
PROGRAMMED VOLUME  
or  
1.05 – 1.44  
If #59 is LTR  
0 - 1  
1.24  
0
64  
65  
Keypad Test  
Tests function of control panel switches.  
0 - Skip keypad test  
1 - Keypad test active  
Starting at the stop buttons, press each button  
that is lit. The display will show the name of the  
switch being pressed. Brew switches are named  
S1, S2, S3, etc. The hot water switch must be  
pressed last, as this will exit the test.  
0 - Skip relay test. Loop back to #50  
Relay Test  
0 - 1  
0
1 – Relay test active.  
Press STOP to continue  
Press  
Press  
to save the settings and exit Diagnostic mode.  
again to exit Programming mode and return to Operating mode.  
Relay Test  
Warning: During these  
tests, hot water may  
be dispensed from  
Tests the individual relays which control various components.  
Use either batch button to actuate the relays.  
the valve being tested.  
To begin, you must first press the blinking Control Panel Power Switch.  
Address  
Description  
Comment  
90  
91  
92  
93  
94  
95  
Left or Single Brew Valve  
Right Brew Valve  
Left or Single Bypass Valve  
Right Bypass Valve  
Hot Water Faucet  
Fill Valve  
96  
Heater  
To protect the heaters, this test will work only if the tank is full.  
97  
98  
Left or Single Brew Basket Lock  
Right Brew Basket Lock  
Press  
to exit Relay Test.  
Press  
Press  
again to exit Diagnostic mode.  
again to exit Programming mode and return to Operating mode.  
12  
Error Codes  
How to Clear Error  
Codes  
Code  
Description  
Possible Cause  
Corrective Action  
001  
Internal Error  
System had to reload  
default settings.  
Control board failure.  
Clear error.  
Turn main power  
switch off and on.  
Re-program the brewer to  
the desired specifications. If  
error occurs again, replace  
control board.  
050  
051  
075  
Shorted temperature probe. Probe failure.  
Replace probe.  
Turn main power  
switch off and on.  
Turn main power  
switch off and on.  
Press the flashing  
control panel power  
switch to resume  
operation.  
Open temperature probe.  
Bad probe connection, Check all connections.  
or probe failure. Replace probe if necessary.  
Brew basket lock or sensor Brew basket sensor or Repair or replace brew  
failure.  
lock has failed.  
basket sensor or lock.  
Basket was in place when  
brew cycle started, but was  
pulled out during the brew  
cycle. If this error occurs,  
the brew basket lock has  
failed.  
Magnet in brew basket Remove brew basket  
handle is missing or  
loose.  
handle. Place magnet in  
correct position.  
100  
101  
102  
Initial Fill Error  
Initial fill time was more  
than 15 minutes.  
Water supply flow rate Watch for short potting  
Press the control  
panel power switch.  
is too low.  
during brew cycle.  
Investigate cause of low flow  
rate. (Clogged water filter,  
etc.)  
Error on refill  
Tank did not refill within 3  
minutes.  
Water supply flow rate Watch for short potting  
Error message is  
cleared  
is too low.  
during brew cycle.  
Investigate cause of low flow automatically at  
rate. (Clogged water filter,  
etc.)  
end of brew cycle.  
Unwanted Fill  
Possible leak in tank,  
fitting, or valve.  
Check inside of machine for  
leaks.  
Turn main power  
switch off and on.  
When brewer is idle, the fill  
valve was activated for  
more than 30 seconds  
during a 1 hour period.  
Output on control  
board has failed,  
causing a dispense  
valve to open.  
Replace control board.  
200  
201  
Flat Line Temperature  
(Water is boiling)  
System is calling for heat,  
but the temperature does  
not rise at least 2°F within  
10 minutes.  
Triac is stuck closed,  
bad output on control  
board, or temperature  
is set too high for  
altitude.  
Check triacs, check control  
board output, or adjust  
temperature for altitude.  
Turn main power  
switch off and on.  
Heater Open  
Heating element  
failure.  
Check and replace heating  
elements if necessary.  
Turn main power  
switch off and on.  
System is calling for heat,  
but the temperature does  
not rise at least 2°F within  
10 minutes. This error is  
disabled during brewing  
and while using the hot  
water faucet.  
202  
255  
Heater Short  
Possible triac stuck  
closed, or bad output  
on control board.  
Check triac and control  
board.  
Enter programming  
mode, then exit  
programming  
mode.  
Turn main power  
switch off and on.  
System is not calling for  
heat, but temperature rises  
more than 5°F.  
Keypad Error  
A switch was pressed for  
more than 45 seconds.  
Switch was held in too Clear error and try again. If  
long, or switch is stuck error occurs without switch  
closed.  
being pressed, replace input  
board.  
13  
Parts  
Figure 1 – CBS-2051e Main Assembly  
DWG 101191-B  
ITEM #  
QTY  
1
1
PART # DESCRIPTION  
1
2
2
3
4
5
6
7
8
9
10  
11  
11  
11  
12  
13  
14  
15  
16  
17  
001049 WELDMENT CBS-2051e  
57006 FILL VALVE, S-53 120VAC  
57017 FILL VALVE, S-53 220VAC  
24012 GASKET, S-53 FILL VALVE  
31078 FITTING, S-53 FILL VALVE INLET  
03074 BRACKET, S-53  
82020 SCREW, S-53 FILL VALVE  
31031 FITTING, 90° MALE ELBOW, 3/8 TUBE OD X 3/8 MPT  
86040 CONNECTOR, CABLE CLAMP, 3/4"  
86032 BUSHING, SNAP, 1" MOUNTING HOLE DIA  
29020 SPACER, HOT WATER VALVE  
102192 ASSEMBLY, HOT WATER VALVE, 120VAC  
102193 ASSEMBLY, HOT WATER VALVE, 220VAC  
EXPORT  
220V ONLY  
1
1
1
1
4
1
1
2
2
1
1
EXPORT  
220V ONLY  
57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)  
83051 WASHER, #8 SCREW SIZE, FLAT  
4
20  
1
1
1
84002 NUT, HEX, #8-32 MACHINE SCREW  
002065 WELDMENT, HOT WATER FAUCET  
33007 LOCKNUT, 7/16 STRAIGHT PIPE THREAD  
108003 SWITCHING/ CONTROL BOARD, 6 KEYS, S3P  
46029 LABEL, POWER SWITCH  
1
14  
18  
19  
20  
20  
21  
22  
23  
24  
25  
26  
27  
28  
28  
29  
29  
30  
31  
32  
32  
32  
33  
34  
35  
35  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
58  
59  
60  
61  
62  
63  
64  
4
4
1
1
4
1
1
12  
1
1
1
1
1
1
1
1
1
1
1
15007 STANDOFF, MALE-FEMALE, THREADED HEX 4-40-1/2"  
29007 NUT, #4-40 KNURLED THUMB  
51042 BOARD, POWER SUPPLY-120VAC  
51055 BOARD, POWER SUPPLY-220VAC  
29019 SPACER, .25" HEX x 1" LG., FEM, #4-40 THREAD  
65002 CONNECTOR, COPPER LUG  
52050 TERMINAL BLOCK  
83026 WASHER, INTERNAL TOOTH LOCK, #8 SCREW SIZE,  
104029 ASSEMBLY, TANK CBS-2051e  
22057 INSULATION TANK FRONT CBS-2051  
22058 INSULATION TANK REAR CBS-2051  
102102 ASSEMBLY, LARGE SPRAY HEAD, 120V (SEE FIG. 5)  
102159 ASSEMBLY, LARGE SPRAY HEAD, 220V (SEE FIG. 5)  
101160 ASSEMBLY, BREW BASKET LOCK. 120 VAC  
101174 ASSEMBLY, BREW BASKET LOCK. 220 VAC  
102147 WELDMENT, BRACKET BY-PASS VALVE  
102207 ASSEMBLY, REED SWITCH  
57044 VALVE, BYPASS LEFT 120 VAC  
57077 VALVE, BYPASS LEFT 220 VAC  
57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)  
84030 LOCKNUT, #8-32 SCREW SIZE, HEX THIN NYLON INSERT  
45081 OVERLAY, CBS-2051e  
102189 ASSEMBLY, POWER BRACKET, CBS-2000e  
52026 CIRCUIT BREAKER, 5A  
EXPORT  
220V ONLY  
EXPORT  
220V ONLY  
EXPORT  
220V ONLY  
EXPORT  
220V ONLY  
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
6
1
1
3
1
1
1
1
1
2
1
1
1
1
11  
1
4
1
58054 SWITCH, PUSH BUTTON  
25090 TUBE, 5/8"OD X 3/8"ID X 17"LG, COLD WATER  
25044 TUBE, 5/8"OD X 3/8"ID X 7.5"LG, BY-PASS  
25042 TUBE, 1/2"OD X 1/4"ID X 7 1/2" LG, VENT  
25104 TUBE, 1/4"X11/8"X25"LG, VENT HOT WATER VALVE  
25105 TUBE, 5/8"OD X 3/8"ID X 2.5"LG, HOT WATER VALVE OUTLET  
25106 TUBE, 5/8"OD X 3/8"ID X 11"LG, HOT WATER VALVE INLET  
25045 TUBE, 31/32"OD X 5/8"ID X 4 1/4" LG, BREW  
25046 TUBE, 5/8"OD X 3/8"ID X 15"LG, DRAIN  
25060 TUBE 5/8"OD X 3/8"ID X 1.5"LG, BY-PASS  
25061 TUBE 1/2"OD X 1/4"ID X 1/2""LG, BY-PASS  
86007 CLAMP, HOSE, .593"-.656" DIA RANGE  
86036 CLAMP, HOSE, .875"-1.0" DIA RANGE  
86039 CLAMP, HOSE, 1.031"-1.187" DIA RANGE  
86038 CLAMP, HOSE, .670"-.780" DIA RANGE  
402016 HARNESS, ELECTRICAL, MAIN CBS-2051e  
402030 HARNESS, ELECTRICAL, TWO HEATER WIRE SET CBS-2051e  
102202 ASSEMBLY, WATER LEVEL PROBE, CBS-2040, -50e  
102172 ASSEMBLY, PROBE DIGITAL TEMPERATURE 8.0" LG  
41016 LABEL, EXTRACTOR  
44024 LABEL, WARNING-HIGH VOLTAGE  
44004 LABEL GROUND  
01501 COVER, UPPER BASE CBS-2051e  
102194 ASSEMBLY, RIGHT COVER CBS-2050e'S  
01502 COVER, TOP CBS-2051e  
82059 SCREW, #8-32 X 3/8 TRUSS HD PHIL., MACHINE  
401213 WIRING DIAGRAM, CBS-2051 UNIV. WIR. 1PH, 3WIR+GR, 2 HEAT.  
73011 LEG, FLANGE FOOT, 4" HIGH  
101165 ASSEMBLY, BREW BASKET, 16" X 6", DIA HOLE 0.280" (SEE FIG.6)  
15  
Figure 2 – CBS-2051e Tank Assembly  
DWG 104029-C  
ITEM #  
1
QTY  
1
PART # DESCRIPTION  
4039 WELDMENT, TANK CBS-2051e  
2
3
4
5
6
7
1
1
1
1
1
1
83041 WASHER, .812"OD X .412"ID, FLAT  
31005 FITTING, 90 ELBOW, 1/4 HOSE ID X 1/8 MPT  
31116 LOCKNUT 1/8 STRAIGHT PIPE THREAD  
83043 WASHER, 1.125"OD X 0.688"ID FLAT  
83048 WASHER, 1.250"OD X 0.835"ID FLAT  
31077 FITTING, 3/8 HOSE ID X 3/8 MPT  
8
1
31150 FITTING, 5/8 HOSE ID X 1/2 MPT  
9
1
1
3
2
1
1
1
2
31118 LOCKNUT 3/8 STRAIGHT PIPE THREAD  
31151 LOCKNUT 1/2 STRAIGHT PIPE THREAD  
31021 BUSHING, 3/4-16 X 1/4 NPSM, HEX HEAD  
107002 HEATER ASSY., 3000W, 240VAC  
84007 NUT, 3/4-16 HEX JAM  
31152 VALVE, COMPR 3/8 TUBE OD X 1/4 MPT  
13055 TUBE, VALVE DRAIN , 3/8" OD X .035"TH X 1.5" LG  
31128 FITTING, 90° ELBOW, 3/8 HOSE ID X 1/4 MPT  
31027 FITTING, COMPR 90° MALE ELBOW, 3/8 TUBE OD X 1/4 MPT  
10  
11  
12  
13  
14  
15  
16  
17  
1
16  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
1
3
1
3
1
1
1
1
2
2
8
8
2
2
13072 OUTLET, INSIDE TANK HOT WATER  
83042 WASHER, .875"OD X .562"ID, FLAT  
31036 FITTING COMPR. MALE CONNECTOR 1/4 TUBE OD X 1/4 MPT  
31117 LOCKNUT 1/4 STRAIGHT PIPE THREAD  
25098 FITTING, COMPRESSION MALE CONNECTOR  
31081 PLUG, HEX HEAD 1/4" MPT  
24002 O-RING, TANK COVER  
102013 ASSEMBLY, TANK COVER  
3332 BRACKET 2, ONE SHOT THERMOSTAT  
53064 THERMOSTAT, SINGLE SHOT,TRIAC  
83011 WASHER, #6 SCREW SIZE, INTERNAL  
84001 NUT, HEX, #6-32 MACHINE SCREW  
3297 SINK, HEAT FOR 40A TRIAC  
59008 TRIAC 40A, 600V  
17  
Figure 3 – CBS-2052e / 2052e20 Main Assembly  
DWG 101197-B  
ITEM #  
QTY  
2
2
2
1
1
1
1
1
PART # DESCRIPTION  
2
3
4
5
5
5
6
7
8
86021 BUSHING, SNAP, 1.375 MTG HOLE  
86018 PLUG, DOME, 1.375 MOUNTING HOLE  
86032 BUSHING, SNAP, 1" MOUNTING HOLE DIA  
102189 ASSEMBLY, POWER BRACKET, CBS-2000e  
52026 CIRCUIT BREAKER, 5A  
58054 SWITCH, PUSH BUTTON  
102104 ASSEMBLY, TERMINAL BLOCK  
65002 CONNECTOR, COPPER LUG  
57001 FILL VALVE ASSY., S-45, 120VAC  
57022 FILL VALVE ASSY., S-45, 220VAC  
83026 WASHER, INTERNAL TOOTH LOCK, #8 SCREW SIZE,  
84002 NUT, HEX, #8-32 MACHINE SCREW  
108005 SWITCHING / CONTROL BOARD,10 KEYS, D3P (CBS-2052e)  
108065 SWITCHING / CONTROL BOARD,10 KEYS, D3P (CBS-2052e20)  
29007 NUT, #4-40 KNURLED THUMB  
15007 STANDOFF, MALE-FEMALE, THREADED HEX 4-40-1/2"  
51042 BOARD, POWER SUPPLY-120VAC  
51055 BOARD, POWER SUPPLY-220VAC  
29019 SPACER, .25" HEX x 1" LG., FEM, #4-40 THREAD  
29020 SPACER, HOT WATER VALVE  
1
EXPORT  
220V ONLY  
8
9
1
18  
32  
1
1
9
4
1
1
2
10  
12  
12  
13  
14  
15  
15  
16  
17  
18  
EXPORT  
220V ONLY  
2
1
102192 ASSEMBLY, HOT WATER VALVE, 120VAC  
18  
EXPORT  
220V ONLY  
18  
18  
19  
20  
21  
22  
23  
24  
24  
25  
26  
27  
27  
27  
28  
28  
28  
29  
29  
30  
31  
32  
33  
34  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
58  
58  
59  
60  
61  
64  
1
102193 ASSEMBLY, HOT WATER VALVE, 220VAC  
57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)  
102202 ASSEMBLY, WATER LEVEL PROBE, CBS-2040, -50e  
83051 WASHER, #8 SCREW SIZE, FLAT  
002065 WELDMENT, HOT WATER FAUCET  
33007 LOCKNUT, 7/16 STRAIGHT PIPE THREAD  
45082 OVERLAY, CBS-2052e  
102102 ASSEMBLY, LARGE SPRAY HEAD, 120V (SEE FIG 5)  
102159 ASSEMBLY, LARGE SPRAY HEAD, 220V (SEE FIG 5)  
102147 WELDMENT, BRACKET BY-PASS VALVE  
46029 LABEL, POWER SWITCH  
57043 VALVE, BYPASS RIGHT 120 VAC  
57076 VALVE, BYPASS RIGHT 220 VAC  
57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)  
57044 VALVE, BYPASS LEFT 120 VAC  
57077 VALVE, BYPASS LEFT 220 VAC  
57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)  
101160 ASSEMBLY, BREW BASKET LOCK. 120 VAC  
101174 ASSEMBLY, BREW BASKET LOCK. 220 VAC  
22036 INSULATION-FRONT, TANK CBS-2052  
1
6
1
1
1
2
2
2
1
1
1
EXPORT  
220V ONLY  
EXPORT  
220V ONLY  
1
1
EXPORT  
220V ONLY  
2
2
1
1
1
4
1
1
4
1
2
2
2
2
2
1
1
5
2
2
2
1
1
1
1
1
2
1
1
1
1
1
1
11  
2
3
EXPORT  
220V ONLY  
22037 INSULATION, TANK-BACK CBS-2052  
104026 ASSEMBLY, TANK CBS-2052e (SEE FIG. 4)  
84030 LOCKNUT, #8-32 SCREW SIZE, HEX THIN NYLON INSERT  
32050 TUBE, COLD WATER (CBS-2052e)  
13122 TUBE, COLD WATER (CBS-2052e20)  
86007 CLAMP, HOSE, .593"-.656" DIA RANGE  
25046 TUBE, 5/8"OD X 3/8"ID X 15"LG, DRAIN  
25045 TUBE, 31/32"OD X 5/8"ID X 4 1/4" LG, BREW  
25044 TUBE, 5/8"OD X 3/8"ID X 7.5"LG, BY-PASS  
25042 TUBE, 1/2"OD X 1/4"ID X 7 1/2" LG, VENT  
25060 TUBE 5/8"OD X 3/8"ID X 1.5"LG, BY-PASS  
25061 TUBE 1/2"OD X 1/4"ID X 1/2""LG, BY-PASS  
25106 TUBE, 5/8"OD X 3/8"ID X 11"LG, HOT WATER VALVE INLET  
25105 TUBE, 5/8"OD X 3/8"ID X 2.5"LG, HOT WATER VALVE OUTLET  
86038 CLAMP, HOSE, .670"-.780" DIA RANGE  
86036 CLAMP, HOSE, .875"-1.0" DIA RANGE  
86039 CLAMP, HOSE, 1.031"-1.187" DIA RANGE  
102207 ASSEMBLY, REED SWITCH  
102172 ASSEMBLY, PROBE DIGITAL TEMPERATURE 8.0" LG  
44019 LABEL, SINGLE PHASE CONFIGURATION  
402013 HARNESS ELECTRICAL, CBS-2052e, (THREE HEATERS)  
402028 HARNESS, ELECTRICAL, THREE HEATER WIRE SET. CBS-2052e  
44022 LABEL, CONNECTION WARNING FOR 3 PH  
44024 LABEL, WARNING-HIGH VOLTAGE  
102202 ASSEMBLY, WATER LEVEL PROBE, CBS-2040, -50e  
01445 COVER, TOP CBS-2052e  
01446 COVER, UPPER BASE CBS-2052e  
102194 ASSEMBLY, RIGHT COVER (CBS-2050e)  
102286 ASSEMBLY, RIGHT COVER (CBS-2050e20)  
46027 LABEL, SPRAY HOUSING  
82059 SCREW, #8-32 X 3/8 TRUSS HD PHIL., MACHINE  
101165 ASSEMBLY, BREW BASKET, 16" X 6", 0.280" HOLE (SEE FIG 6)  
73011 LEG, FLANGE FOOT, 4" HIGH  
19  
Figure 4 – CBS-2052e / 2052e20 Tank Assembly  
DWG 104026-A  
ITEM #  
1
QTY  
1
3
1
1
1
1
2
1
1
2
2
2
2
2
2
2
2
2
3
1
PART # DESCRIPTION  
004038 WELDMENT, TANK CBS-2052e  
31021 BUSHING, 3/4-16 X 1/4 NPSM, HEX HEAD  
84007 NUT, 3/4-16 HEX JAM  
31082 FITTING, HEX NIPPLE, 3/8 MPT X 1/4 MPT  
34004 VALVE, BALL 3/8 FPT X 3/8 FPT  
31054 FITTING, 1/2 HOSE ID X 3/8 MPT  
31027 FITTING, COMPR 90° MALE ELBOW, 3/8 TUBE OD X 1/4 MPT  
31128 FITTING, 90° ELBOW, 3/8 HOSE ID X 1/4 MPT  
13072 OUTLET, INSIDE TANK HOT WATER  
83048 WASHER, 1.250"OD X 0.835"ID FLAT  
83043 WASHER, 1.125"OD X 0.688"ID FLAT  
31150 FITTING, 5/8 HOSE ID X 1/2 MPT  
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
31077 FITTING, 3/8 HOSE ID X 3/8 MPT  
31151 LOCKNUT 1/2 STRAIGHT PIPE THREAD  
31118 LOCKNUT 3/8 STRAIGHT PIPE THREAD  
83041 WASHER, .812"OD X .412"ID, FLAT  
31005 FITTING, 90° ELBOW, 1/4 HOSE ID X 1/8 MPT  
31116 LOCKNUT 1/8 STRAIGHT PIPE THREAD  
83042 WASHER, .875"OD X .562"ID, FLAT  
25098 FITTING, COMPRESSION MALE CONNECTOR  
20  
21  
22  
23  
24  
25  
26  
27  
28  
28  
29  
30  
31  
32  
1
3
3
12  
12  
3
1
3
3
3
31036 FITTING COMPR. MALE CONNECTOR 1/4 TUBE OD X 1/4 MPT  
03332 BRACKET 2, ONE SHOT THERMOSTAT  
53064 THERMOSTAT, SINGLE SHOT,TRIAC  
83011 WASHER, #6 SCREW SIZE, INTERNAL  
84001 NUT, HEX, #6-32 MACHINE SCREW  
31117 LOCKNUT 1/4 STRAIGHT PIPE THREAD  
31081 PLUG, HEX HEAD 1/4" MPT  
107002 HEATER ASSY., 3000W, 240VAC  
107018 HEATER ASSY., 5000W, 240VAC  
03297 SINK, HEAT FOR 40A TRIAC  
3
1
1
59008 TRIAC 40A, 600V  
24002 O-RING, TANK COVER  
102013 ASSEMBLY, TANK COVER  
21  
Figure 5 – Spray Housing Assembly, 120 VAC, Part # 102102  
Spray Housing Assembly, 220 VAC, Part # 102159 (EXPORT ONLY)  
ITEM #  
QTY  
4
PART # DESCRIPTION  
1
2
82112 #8 X 3/4'' PAN HD. PHIL. T.S. 18-8 S.S. SCREW  
57042 VALVE ASSY., DSV-10, 120 VAC  
1
EXPORT  
220V ONLY  
2
3
4
5
6
1
1
1
1
1
57075 VALVE ASSY., DSV-10, 240 VAC  
57072 VALVE REBUILD KIT, DSV-10  
102113 SPRAY HOUSING ASSY.  
24035 O-RING, 5.5 I.D. X 5 11/16 O.D. X 3/32  
102108 SPRAY PLATE ASSY., 5 7/8" DIA.  
22  
Figure 6 – Brew Basket Assembly, 16” X 6”, Part # 101165  
ITEM  
QTY  
PART # DESCRIPTION  
1
1
1
82096 HANDLE SCREW  
BREW BASKET HANDLE, BLACK  
2
3
23117  
(includes magnet)  
1
1
9006 WIRE INSERT, 16 X 6  
46011 WARNING LABEL  
NOT  
SHOWN  
NOT  
SHOWN  
PAPER FILTERS, 15” X 5.5”  
500 PER CASE  
F001  
COLOR BREW BASKET HANDLES  
PART # DESCRIPTION  
23106 BREW BASKET HANDLE, GREEN  
23107 BREW BASKET HANDLE, ORANGE  
23148 BREW BASKET HANDLE, RED  
23  

NETGEAR Netgear ProSafe Wireless Management Software WMS105 10000S User Manual
Maxtor DIAMONDMAX PLUS 40 52049U4 User Manual
Keurig Mini Brewers User Manual
Kalorik Team International Group Coffeemaker CM 38933 User Manual
Hitachi Travelstar HTS722020K9SA00 User Manual
Gigabyte GA 7VAC User Manual
Ericsson T18d User Manual
Cub Cadet 650 User Manual
Continental Electric CM43655 User Manual
Braun Sommelier KF 610 User Manual