Fetco Home Decor Coffeemaker CBS 2032E User Manual

User’s Guide  
Models:  
f
CBS-2031e / CBS-2031s  
CBS-2032e / CBS-2032s  
f
NOTICE TO INSTALLER: Please leave this book with the machine.  
Table of Contents  
Contact Information ..................................................2  
Operating Instructions ..............................................8  
Programming............................................................9  
Batch Settings.......................................................9  
Temperature Settings .........................................10  
Advanced Settings and Diagnostics ...................10  
Relay Test...........................................................11  
Error Codes ............................................................12  
Parts .......................................................................13  
Description & Features.............................................2  
Specifications............................................................2  
Requirements........................................................2  
Weights and Capacities ........................................2  
Electrical Configuration and Brewing Efficiency ...3  
Dimensions & Utility Connections.............................4  
Installation.................................................................5  
FETCO®, LUXUS®, EXTRACTOR® and Driven To Pioneer Innovation™ are trademarks or trade names of Food Equipment Technologies Company.  
© 2005 Food Equipment Technologies Company Part # P019 August 16, 2005  
Electrical Configuration and Brewing Efficiency  
US & Canada  
CBS-2031e / CBS-2031s  
3.0 liters per batch  
Batches per Hour* (max 11)  
Electrical  
Heater  
Voltage  
(AC)  
Maximum  
Amp draw  
Config. Code  
Configuration  
Phase  
Wires  
KW  
1.6  
2.4  
2.6  
3.1  
Cold Water  
Hot Water  
E31045  
Can be connected  
1 X 1.5 KW  
2 X 1.5 KW  
120  
single 2 + ground  
13.0  
11.3  
12.0  
13.0  
4.9  
11.0  
120/208 single 3 + ground  
120/220  
120/240  
7.3  
11.0  
to 120 VAC or  
8.2  
11.0  
120/208-240 VAC  
9.7  
11.0  
E31035  
Can be connected  
1 X 1.7 KW  
2 X 1.7 KW  
120  
single 2 + ground  
1.8  
2.7  
3.0  
3.5  
14.7  
12.8  
13.5  
14.7  
5.5  
8.3  
9.2  
11.0  
11.0  
11.0  
11.0  
120/208 single 3 + ground  
120/220  
120/240  
to 120 VAC or  
120/208-240 VAC  
11.0  
E31015  
Can be connected  
1 X 2.3 KW  
2 X 2.3 KW  
120  
single 2 + ground  
2.4  
3.6  
4.1  
4.7  
19.7  
17.1  
18.1  
19.7  
7.4  
11.0  
11.0  
11.0  
11.0  
120/208 single 3 + ground  
120/220  
120/240  
11.0  
11.0  
11.0  
to 120 VAC or  
120/208-240 VAC  
CBS-2032e / CBS-2032s  
3.0 liters per batch  
Batches per Hour* (max 22)  
Electrical  
Heater  
Voltage  
(AC)  
Maximum  
Amp draw  
Config. Code  
Configuration  
Phase  
Wires  
KW  
Cold Water  
Hot Water  
E32015  
2 X 3 KW  
120/208 single 3 + ground 4.6  
22.4  
23.7  
25.8  
14.6  
16.9  
19.4  
22.0  
22.0  
22.0  
120/220  
120/240  
5.1  
6.1  
* Based on standard factory settings: 4.0 minute brew time; 0% prewet; 200 F water.  
Export  
CBS-2031e / CBS-2031s  
3.0 liters per batch  
Batches per Hour* (max 11)  
Electrical  
Heater  
Voltage  
(AC)  
Maximum  
Amp draw  
Config. Code  
Configuration  
Phase  
Wires  
KW  
Cold Water  
Hot Water  
E31025  
1 X 3 KW  
220  
single 2 + ground 2.6  
12.0  
8.4  
11..0  
CBS-2032e / CBS-2032s  
3.0 liters per batch  
Batches per Hour* (max 22)  
Electrical  
Heater  
Voltage  
(AC)  
Maximum  
Amp draw  
Config. Code  
Configuration  
Phase  
Wires  
KW  
Cold Water  
Hot Water  
E32025  
2 X 3 KW  
220  
single 2 + ground 5.1  
23.7  
16.9  
22.0  
* Based on standard factory settings: 4.0 minute brew time; 0% prewet; 200 F water.  
3
Dimensions & Utility Connections  
CBS-2031e / CBS-2031s  
DWG 201108-000  
CBS-2032e / CBS-2032s  
DWG 201109-000  
4
Installation  
(For Qualified Service Technicians Only)  
Keys To A Successful Installation  
If not installed correctly by qualified personnel, the brewer will not operate properly and damage may result.  
Damages resulting from improper installation are not covered by the warranty.  
Here are the key points to consider before installation:  
Electrical:  
All FETCO brewers require NEUTRAL. Ground is not an acceptable substitute. Installation without neutral  
may cause damage to the electronic components.  
The electrical diagram is located on the inside of the lower cover.  
The installation must comply with applicable federal, state, and local codes having jurisdiction at your  
location. Check with your local inspectors to determine what codes will apply.  
Plumbing:  
This equipment is to be installed to comply with the applicable federal, state, or local plumbing codes.  
The water line must be flushed thoroughly prior to connecting it to the brewer to prevent debris from  
contaminating the machine.  
Verify that the water line will provide at least ¼ gallon per minute for the CBS-2031, and ½ gallons per  
minute for the CBS-2032 before connecting it to the brewer.  
General:  
Utilize only qualified beverage equipment service technicians for installation. A Service Company Directory  
may be found on our web site, http://www.fetco.com.  
Installation Instructions  
Brewer Setup  
1. Review the Dimensions for the unit you are installing. Verify that the brewer will fit in the space intended for it,  
and that the counter or table will support the total weight of the brewer and dispensers when filled.  
2. The brewer’s legs are shipped inside the brew baskets.  
Warning: Legs are to be adjusted for  
leveling the brewer only. Do not use  
for height adjustment or extend them  
higher than necessary.  
Remove the brew basket(s) and the coffee dispenser(s).  
Place the brewer on its back and screw in the legs.  
3. Place the brewer on the counter or stand.  
4. When the brewer is in position, level it front to back as well  
as side to side by adjusting the legs.  
5. Remove the lower cover to access the water and electrical connections. Knock-outs are provided in the back  
and base of the brewer body for the connections.  
Water Connection  
1. Water inlet is a 3/8 inch male flare fitting.  
2. The brewer can be connected to a cold or hot water line. Cold water is preferred for best coffee flavor, but hot  
water will allow for faster recovery times.  
3. Install a water shut off valve near the brewer to facilitate service. If an in-line water filter is used, it should be  
installed after the water shut off valve and in a position to facilitate filter replacement.  
4. Flush the water supply line and filter before connecting it to the brewer.  
5. Verify that the water line will provide at least ¼ gallon per minute for the CBS-2031, and ½ gallon per minute  
for the CBS-2032, and that the water pressure is between 20 and 75 psig.  
5
Electrical Connection – US & Canada  
1. Verify that the actual voltage at the electrical service connection is compatible with the specifications on the  
brewer’s serial number label. Make sure the electrical service includes neutral.  
2. The temperature and water tank fill level are pre-set at the factory. There is no need to turn off the heaters  
during the installation process. The heaters are disabled by the control board until the tank is full of water. The  
heating process will start automatically when the tank has filled.  
3. The CBS-2031 is factory equipped with a 120 V cord and plug. The CBS-2032 has only a terminal block for  
connecting the incoming power wires. Consult local codes to determine if a cord and plug can be installed, or if  
the unit must be hard wired.  
4. A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near the  
brewer, and its location and markings known to the operators.  
Warning: To prevent  
electrical shock, this  
unit must be properly  
grounded.  
5. The body of the brewer must be grounded to a suitable building ground.  
A ground lug is provided in the brewer next to the power terminal block.  
Use only 10 gauge copper wire for grounding.  
6. Electrical connections must be secured in-place within the unit to meet  
national and local standards.  
7. Finally, connect the incoming power wires to the terminal block as shown in accordance with applicable codes.  
CBS-2031e / CBS-2031s  
Can be connected to 120 VAC or 120/208-240 VAC  
Factory Configuration  
120 VAC, 3 wires  
Optional Field Conversion*  
120/208-240 VAC, 4 wires  
Step 1: Remove the factory provided 120 V cord &  
plug from the terminal block.  
Step 2: Connect the incoming wires to the terminal  
block in accordance with applicable codes.  
L1  
N
L2  
GROUND  
GROUND LUG  
L1  
N
L2  
L2 - NOT USED  
CORD WITH  
NEMA 5-20P PLUG  
120V  
120V  
N
GROUND  
WIRE  
208-240V  
*This procedure must be performed only by a qualified  
service technician or electrician.  
Notice: In order for this product to comply with the  
requirements of the Underwriters Laboratories listing,  
the following conditions apply:  
1.) This unit must be hard wired for 120/208-240 VAC.  
2.) Once the unit is converted to 120/208-240 VAC  
operation, it cannot be converted back to 120  
VAC operation.  
CBS-2032e / CBS-2032s  
Can be connected only to 120/208-240 VAC  
GROUND LUG  
L1  
N
L2  
120V  
120V  
N
GROUND  
WIRE  
208-240V  
6
Final Setup  
1. Turn on the incoming water supply line and inspect both inside  
and outside of the brewer for leaks in all fittings and tubes  
2. Turn on the incoming power.  
3. Press the brewer’s main power switch, which is hidden behind the  
front leg of the brewer. The control panel on/off switch will begin  
flashing. Press this switch.  
4. Within 6 seconds, the hot water tank will begin filling until the  
water is sensed by the probe at the top of the tank. The display will  
read “FIL”. The heaters will be disabled by the control board until  
the tank is full.  
5. While the water is heating, the display will read “LO” and the  
actual water temperature will be displayed. After the water has  
reached the set temperature, the display will be blank. There is no  
“ready” light.  
6. Review the Operating Instructions. Brew one full batch (water  
only) on each side to confirm proper fill levels. The brewer is  
factory set with water only (no coffee) to dispense the correct  
amount of water. If the actual volume is slightly different from the  
programmed volume, fine tuning the brewer may be necessary.  
See #60 – 61 in the Advanced Settings & Diagnostics section.  
7. Re-attach the covers after one final inspection for leaks. Look  
closely in the top of the brewer at the dispense fittings during this  
inspection.  
Operator Training  
Review the operating procedures with whoever will be using the  
brewer. Pay particular attention to the following areas:  
1. Always pre-heat the dispensers before the first use of each day by  
filling them half way with hot water, and letting them stand for at  
least 15 minutes.  
2. Don't remove the brew basket until it has stopped dripping.  
3. Make sure the dispenser is empty before brewing into it.  
4. Show how to attach covers, close, and or secure the thermal  
dispensers for transporting.  
5. Show the location and operation of the water shut off valve as well  
as the circuit breaker for the brewer.  
6. Steam from the tank will form condensation in the vent tubes. This  
condensation will drip into and then out of the brew baskets. 1/4  
cup discharging overnight is possible. Place an appropriate  
container under each brew basket when not in use.  
7. We recommend leaving the power to the brewer on overnight. The  
water tank is well insulated and will use very little electricity to  
keep the tank hot. Leaving the brewer in the on position will also  
avoid delays at the beginning of shifts for the brewer to reach  
operating temperature.  
7
Operating Instructions  
Control Panel Functions  
Only switches that are active are illuminated.  
Switches that are inactive or disabled are invisible.  
X Main Power Switch  
Controls all power to brewer  
Indicator lamp at top of panel.  
Y Control Panel On/Off Switch  
Affects only control panel. Does  
not disconnect main power.  
Flashing = Off  
Lit = On  
Invisible = Main Power Off  
Z Display  
”FILL” = Water tank is filling.  
”LO XXX” = Unit is heating, not  
ready to brew. (XXX = actual  
temperature.)  
Blank = Ready to brew.  
Also displays error messages.  
[ Stop Switches  
Stops brew cycle  
Lit = Brew cycle in progress  
Invisible = Not brewing, or dripping  
in progress  
\ Brew Switches  
Starts brew cycle  
Must be held in for 1 second  
Flashing = Brew cycle in progress  
Lit = Ready to brew  
Invisible – Not ready to brew, or  
batch disabled  
(See Programming Section)  
] Hot Water Switch  
Dispenses hot water from faucet  
Hold in to dispense  
Brewing  
1. Turn the main power switch and control  
panel switch on.  
7. When the brew cycle is finished, the STOP  
button will extinguish and the BREW button will  
continue flashing, indicating that coffee may still  
be dripping from the bottom of the brew basket.  
8. Before removing the brew basket or dispenser,  
visually verify that dripping has stopped.  
Notes:  
2. Prepare a brew basket with the correct size  
filter and appropriate amount of coffee.  
3. Slide the brew basket completely into the  
rails.  
4. Place a clean, empty, preheated dispenser  
under the brew basket.  
5. Select a batch from the available choices,  
and hold the corresponding BREW button in  
for 1 second to start the brew cycle.  
6. The STOP button will illuminate, and the  
selected BREW button will flash, indicating  
that brewing is in progress. All other BREW  
buttons will extinguish.  
Preheat dispenser by filling at least ½ full with  
water at brewing temperature. Allow it to sit for  
at least 15 minutes before draining.  
8
Programming  
Display  
Batch Settings  
Turn the brewer off by pressing the main power switch.  
Press the main power switch again to turn the unit on.  
32  
The last 2 digits of the model number will display briefly, then S t b.  
S t b  
Quickly hold the STOP button for 3 seconds.  
The display will show the software version. Example:  
Press STOP to continue.  
P r G  
MAIN POWER  
SWITCH IS  
BEHIND  
0.0 3.2  
FRONT LEG.  
Batches are numbered 1 – 2 (single brewers) or 1 – 4 (dual brewers)  
PARAMETER  
BATCH #  
SETTING  
1.1 2.49  
Example: Left Side – Large Batch – Volume 2.49 Liters.  
Next, the first batch parameter is displayed – batch 1, brew volume  
Use the SCROLL UP and SCROLL DOWN buttons to adjust.  
Press the STOP button to go to the next parameter – brew time.  
1.1 2.49  
1.2 4.00  
Continue this way until all parameters are programmed for batch #1.  
(See the chart below for an explanation of each parameter.)  
Next, batch #2 programming begins.  
2.0 OFF  
Batches 2 and 4 may be disabled by leaving them set to “OFF”.  
Change to “ON” to enable. Batches 1 and 3 cannot be disabled.  
After all batches are programmed, go to temperature settings.  
7
200  
(See next page)  
Important! After programming, you must press the HOT WATER button to save the settings and exit  
programming mode, or changes will be lost. You may exit programming at any time.  
Batch Parameters  
X=Batch Number (1 - 4)  
Parameter  
Name  
Range  
Increment  
Default Setting  
Comment  
X.0  
Batch Enabled or  
Disabled  
Brew Volume (Liters) 0.94 – 4.72  
On/Off  
Batch 1 & 3 = ON  
Batch 2 & 4 = OFF  
2.49 liters  
Batch 1 & 3 cannot be  
disabled.  
To display gallons,  
see # 59 in Advanced  
Settings section.  
X.1  
0.03 or  
0.04  
X.2  
X.3  
Brew Time (Min:Sec) 2:00 – 24:00  
0:30  
1%  
4:00 minutes  
0 %  
Bypass Percent  
0.00 – 40.0%  
0.00 – 15.0%  
0:10 – 5:00  
Percentage of total  
brew volume  
Percentage of total  
brew volume  
The time between  
prewetting and start of  
brew cycle.  
(CBS-2031s / 2032s only)  
X.4  
X.5  
Prewet Percent  
1%  
0 %  
Prewet Delay  
(Min:Sec)  
0:10  
1:00 minute  
X.6  
Drip Delay (Min:Sec) 0:30 – 6:00  
Minutes  
0:10  
1:00 minute  
The time between end  
of brew cycle and  
when brew switch  
stops blinking.  
9
Temperature Settings  
Parameter  
Name  
Range  
Default Setting  
Comment  
7
Inside tank. Will be slightly lower at  
spray head. To display in ° Celsius,  
see # 58 in Advanced Settings.  
A= Faucet will dispense only when not  
brewing.  
On=Faucet always enabled.  
Off=Faucet always disabled.  
0=Will brew at any temperature.  
1=Will brew only at set temperature.  
Note: Changes will not take effect until  
the next brew cycle is completed.  
Water Temp. (°F)  
180°F - 208°F  
200°F  
8
9
Hot Water Service  
A (auto) / On / Off  
A (auto)  
1
Brew at Set  
Temperature  
0 - 1  
Parameter  
Name  
Range  
Default Setting  
Comment  
10  
Enter Advanced  
Settings &  
Diagnostics  
0 - 1  
0
0 = Skip Advanced Settings &  
Diagnostics. Loop back to start of  
batch programming cycle.  
1 = Enter Advanced Settings &  
Diagnostics.  
Press STOP to continue  
Important! To save your changes, press  
to exit programming mode and return to operating mode.  
Advanced Settings and Diagnostics  
Address  
Description  
Water Level  
in Tank  
Range  
Default  
Comment  
50  
0 - 1  
Tests if water is touching probe.  
0 = Tank is less than full  
1 = Tank is full  
52  
Brew Basket  
Sensor State  
(left / right)  
0 - 1  
CBS-2031s / CBS-2032s Only  
To test, slide the brew basket in and out. Display  
should toggle between 0 and 1.  
0 = Brew basket out. 1 = Brew Basket in.  
Displays current tank temperature. If temperature  
is below 175°F, displays “LO”.  
Must be set for the correct model number of the  
brewer: 31 for CBS-2031e or 2031s, 32 for CBS-  
2032e or 2032s.  
55  
56  
Tank Temperature  
180°F - 208°F  
Brewer Model  
Number  
31 - 52  
57  
Reload Defaults  
0 - 1  
0
Changes all settings to default factory settings.  
0 = Do not reload defaults  
1 = Reload all default settings  
If 1 is selected, you must advance to the next  
address for this change to take effect.  
Does not change address 56 – model number.  
F = Displays temp in degrees Fahrenheit  
C = Displays temp in degrees Celsius  
LTR = Displays volume in liters  
58  
59  
Temperature Scale F or C  
F
Water Volume  
Scale  
LTR or GAL  
LTR  
GAL = Displays volume in gallons  
10  
Address  
60  
and  
61  
Description  
Range  
Default  
Comment  
Left Brew Valve  
Flow Rate  
Right Brew Valve  
Flow Rate  
0.35 – 2.24  
If #59 is LTR  
1.48  
Use this to compensate for minor discrepancies in  
actual volume versus programmed volume. Set  
lower to increase volume, higher to decrease  
volume. The following formula can be used to  
determine the correct setting:  
or  
0.09 – 0.59  
If #59 is GAL  
0.39  
0
ACTUAL VOLUME  
CURRENT  
SETTING  
NEW  
SETTING  
X
=
PROGRAMMED VOLUME  
64  
65  
Keypad Test  
0 - 1  
Tests function of control panel switches.  
0 - Skip keypad test  
1 - Keypad test active  
Starting at the top, press each button. Display will  
read the name of the switch being pressed.  
Brew switches are named S1, S2, S3, etc.  
The hot water switch must be pressed last, as this  
will exit the test.  
Relay Test  
0 - 1  
0
0 - Skip relay test. Loop back to #50  
1 – Relay test active.  
Press STOP to continue  
Press  
Press  
to save the settings and exit Diagnostic mode.  
again to exit Programming mode and return to Operating mode.  
Warning: During these  
tests, hot water may  
be dispensed from  
Relay Test  
Tests the individual relays which control various components.  
Use either batch button to actuate the relays.  
the valve being tested.  
To begin, you must first press the blinking Control Panel Power Switch.  
Address  
Description  
Comment  
90  
91  
92  
93  
94  
95  
Left or Single Brew Valve  
Right Brew Valve  
Left or Single Bypass Valve  
Right Bypass Valve  
Hot Water Faucet  
Fill Valve  
CBS-2031s / CBS-2032s Only  
CBS-2031s / CBS-2032s Only  
96  
Heater  
To protect the heaters, this test will work only if the tank is full.  
Press  
to exit Relay Test.  
Press  
Press  
again to exit Diagnostic mode.  
again to exit Programming mode and return to Operating mode.  
11  
Error Codes  
How to Clear Error  
Codes  
Code  
Description  
Possible Cause  
Corrective Action  
001  
Internal Error  
System had to reload default  
settings.  
Control board failure.  
Clear error.  
Turn main power  
switch off and on.  
Re-program the brewer to the  
desired specifications. If error  
occurs again, replace control  
board.  
050  
051  
Shorted temperature probe.  
Open temperature probe.  
Probe failure.  
Replace probe.  
Turn main power  
switch off and on.  
Turn main power  
switch off and on.  
Bad probe connection, or Check all connections. Replace  
probe failure.  
probe if necessary.  
075  
or  
NO  
BAS  
CBS-2031e / 2032e  
Brew Basket Sensor  
These models do not  
have brew basket  
sensors or locks. This  
error indicates a bad  
connection on the brown  
jumper wire on the Molex  
connector connected to  
the top of the control  
board.  
Press both ends of the jumper  
wire into the connector to make  
better contact.  
075  
CBS-2031s / 2032s  
Brew basket lock or sensor  
failure.  
Brew basket sensor or  
lock has failed.  
Repair or replace brew basket  
sensor or lock.  
Press the flashing  
control panel power  
switch to resume  
operation.  
If the brew basket can be  
pulled out during the  
brew cycle, the brew  
basket lock has failed.  
Magnet in brew basket  
handle is missing or  
loose.  
Remove brew basket handle.  
Place magnet in correct  
position.  
100  
101  
102  
Initial Fill Error  
Initial fill time was more than  
15 minutes.  
Water supply flow rate is  
too low.  
Watch for short potting during  
Press the control  
brew cycle. Investigate cause of panel power switch.  
low flow rate. (Clogged water  
filter, etc.)  
Watch for short potting during  
brew cycle. Investigate cause of cleared automatically  
low flow rate. (Clogged water  
filter, etc.)  
Check inside of machine for  
leaks.  
Error on refill  
Tank did not refill within 3  
minutes.  
Water supply flow rate is  
too low.  
Error message is  
at end of brew cycle.  
Unwanted Fill  
Possible leak in tank,  
fitting, or valve.  
Turn main power  
switch off and on.  
When brewer is idle, the fill  
valve was activated for more  
than 30 seconds during a 1  
hour period.  
Output on control board  
has failed, causing a  
dispense valve to open.  
Replace control board.  
200  
201  
Flat Line Temperature  
(Water is boiling)  
System is calling for heat, but  
the temperature does not rise  
at least 2°F within 10 minutes.  
Heater Open  
System is calling for heat, but  
the temperature does not rise  
at least 2°F within 10 minutes.  
This error is disabled during  
brewing and while using the  
hot water faucet.  
Triac is stuck closed, bad Check triacs, check control  
Turn main power  
switch off and on.  
output on control board,  
or temperature is set too  
high for altitude.  
board output, or adjust  
temperature for altitude.  
Heating element failure.  
Check and replace heating  
elements if necessary.  
Turn main power  
switch off and on.  
202  
255  
Heater Short  
Possible triac stuck  
closed, or bad output on  
control board.  
Check triac and control board.  
Enter programming  
mode, then exit  
programming mode.  
System is not calling for heat,  
but temperature rises more  
than 5°F.  
Keypad Error  
Switch was held in too  
Clear error and try again. If  
error occurs without switch  
being pressed, replace input  
board.  
Turn main power  
switch off and on.  
A switch was pressed for more long, or switch is stuck  
than 45 seconds. closed.  
12  
Parts  
Figure 1 – CBS-2031e / CBS-2031s Main Assembly  
DWG 101194-C  
ITEM #  
QTY  
PART # DESCRIPTION  
1
2
2
3
4
5
1
1
1
2
4
1
001051 WELDMENT CBS-2031e  
108001 SWITCHING/CONTROL BOARD, 5 KEYS, S2P (CBS-2031e ONLY)  
108037 SWITCHING/CONTROL BOARD, 5 KEYS, S2P (CBS-2031s ONLY)  
29007 NUT, #4-40 KNURLED THUMB  
15007 STANDOFF, MALE-FEMALE, THREADED HEX 4-40-1/2"  
51042 BOARD, POWER SUPPLY-120VAC  
EXPORT  
220V ONLY  
5
1
51055 BOARD, POWER SUPPLY-220VAC  
6
7
4
1
29019 SPACER, .25" HEX x 1" LG., FEM, #4-40 THREAD  
57006 FILL VALVE, S-53 120VAC  
EXPORT  
220V ONLY  
7
1
57017 FILL VALVE, S-53 220VAC  
8
9
10  
11  
12  
13  
1
1
1
4
1
1
24012 GASKET, S-53 FILL VALVE  
31078 FITTING, S-53 FILL VALVE INLET  
03074 BRACKET, S-53  
82020 SCREW, S-53 FILL VALVE  
31031 FITTING, 90º MALE ELBOW, 3/8 TUBE OD X 3/8 MPT  
86040 CONNECTOR, CABLE CLAMP, 3/4"  
13  
14  
15  
16  
17  
17  
17  
18  
19  
20  
1
1
2
1
1
1
7
13  
1
52050 TERMINAL BLOCK  
65002 CONNECTOR, COPPER LUG  
86032 BUSHING, SNAP, 1" MOUNTING HOLE DIA  
102189 ASSEMBLY, POWER BRACKET, CBS-2000e  
52026 CIRCUIT BREAKER, 5A  
58054 SWITCH, PUSH BUTTON  
83026 WASHER, INTERNAL TOOTH LOCK, #8 SCREW SIZE,  
84002 NUT, HEX, #8-32 MACHINE SCREW  
102080 ASSEMBLY, SMALL SPRAY HEAD, 120V (SEE FIG. 5)  
EXPORT  
220V ONLY  
20  
1
102158 ASSEMBLY, SMALL SPRAY HEAD, 220V (SEE FIG. 5)  
21  
22  
23  
24  
25  
25  
1
1
4
2
1
002065 WELDMENT, HOT WATER FAUCET  
33007 LOCKNUT, 7/16 STRAIGHT PIPE THREAD  
73029 LEG, THERMOPLASTIC, 2.50"(63mm)  
29021 SPACER, #8 SCREW SIZE, ½ OD X ¼ LG, ROUND UNTH.  
102192 ASSEMBLY, HOT WATER VALVE, 120VAC  
57047 VALVE, DSV-11, 120 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)  
EXPORT  
220V ONLY  
EXPORT  
25  
25  
1
102193 ASSEMBLY, HOT WATER VALVE, 220VAC  
57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)  
220V ONLY  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
38  
39  
40  
41  
42  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)  
83051 WASHER, #8 SCREW SIZE, FLAT  
104028 ASSEMBLY TANK CBS-2031e (SEE FIG 2)  
22062 INSULATION TANK FRONT CBS-2031e  
22063 INSULATION TANK BACK CBS-2031e  
45077 OVERLAY CBS-2031e  
41016 LABEL, EXTRACTOR  
46029 LABEL, POWER SWITCH  
102139 ASSEMBLY, WATER LEVEL PROBE, CBS-2030  
102190 ASSEMBLY, DIGITAL TEMP. PROBE, 5.0" LG.  
44004 LABEL GROUND  
402025 HARNESS, LOW AMP, ELECTRICAL, CBS-2031e, TWO HEATERS  
402035 HARNESS, HIGH AMP, ELEC. 2 HEATER WIRE SET CBS-2031e  
63019 CORD, 120 VAC, 12/3 AWG ,20 AMP , W/5-20P NEMA PLUG  
63018 CORD, 120 VAC, 12/3 AWG ,15 AMP , W/5-15P NEMA PLUG  
25056 TUBE, 3/4"OD X 1/2"ID X 4"LG, BREW  
25058 TUBE 5/8"OD X 3/8"ID X 2.5"LG, HOT WATER FAUCET  
86038 CLAMP, HOSE, .670"-.780" DIA RANGE  
86020 CLAMP, HOSE, .875"-.750" DIA RANGE  
25059 TUBE, 5/16"OD X 3/16"ID X 9 1/4"LG VENT  
25102 TUBE, 1/4"OD X 1/8"ID X 20" LG VENT HOT WATER VALVE  
25055 TUBE, 5/8"OD X 3/8"ID X 12"LG DRAIN  
25057 TUBE, 5/8"OD X 3/8"ID X 14 1/2"LG, COLD WATER  
25064 TUBE, 5/8"OD X 3/8"ID X 6.5"LG. HOT WATER  
86007 CLAMP, HOSE, .593"-.656" DIA RANGE  
01506 COVER TOP CBS-2031 & 41  
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
1
1
1
1
1
1
5
1
1
1
1
10  
1
01507 COVER BASE UPPER CBS-2031  
401217 WIRING DIAGRAM, CBS-2031e, L1, L2, N, + GR  
102191 ASSEMBLY, RIGHT COVER CBS-2030's  
82053 SCREW, # 6-32 X 1/2" TRUSS HD PH  
101171 BREW BASKET ASSY., 13 X 5, DIA HOLE 0.218" (SEE FIG. 6)  
ADDITIONAL PARTS FOR CBS-2031s, NOT SHOWN ON DRAWING  
1
1
102207 ASSEMBLY, REED SWITCH  
101160 ASSEMBLY, BREW BASKET LOCK. 120 VAC  
EXPORT  
220V ONLY  
1
1
101174 ASSEMBLY, BREW BASKET LOCK. 220 VAC  
57044 VALVE, BYPASS LEFT 120 VAC  
57047 VALVE, DSV-11, 120 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)  
EXPORT  
220V ONLY  
EXPORT  
1
57077 VALVE, BYPASS LEFT 220 VAC  
57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)  
220V ONLY  
57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)  
101175 BREW BASKET ASSEMBLY, 13 x 5, DIA. HOLE 0.280 (SEE FIG. 7)  
1
14  
Figure 2 – CBS-2031e / CBS-2031s Tank Assembly  
DWG 104028-A  
ITEM #  
QTY  
PART # DESCRIPTION  
1
1
004042 WELDMENT TANK CBS-2031e  
2
3
1
1
3
3
1
1
1
2
2
2
2
1
1
1
2
2
8
24002 O-RING, TANK COVER  
102013 ASSEMBLY, TANK COVER  
4
31117 LOCKNUT 1/4 STRAIGHT PIPE THREAD  
83042 WASHER, .875"OD X .562"ID, FLAT  
31081 PLUG, HEX HEAD 1/4" MPT  
5
6
7
25098 FITTING, COMPRESSION MALE CONNECTOR  
31036 FITTING COMPR. MALE CONNECTOR 1/4 TUBE OD X 1/4 MPT  
107025 HEATER ASSY., 1500W/120VAC  
107019 HEATER ASSY., 1700W/120VAC  
107020 HEATER ASSY., 2300W/120VAC  
107021 HEATER ASSY., 3000W/240VAC  
31116 LOCKNUT 1/8 STRAIGHT PIPE THREAD  
83041 WASHER, .812"OD X .412"ID, FLAT  
31005 FITTING, 90 ELBOW, 1/4 HOSE ID X 1/8 MPT  
03332 BRACKET 2, ONE SHOT THERMOSTAT  
53064 THERMOSTAT, SINGLE SHOT,TRIAC  
83011 WASHER, #6 SCREW SIZE, INTERNAL  
8
9
9
9
EXPORT  
220V ONLY  
9
10  
11  
12  
13  
14  
15  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
8
1
1
1
3
1
1
2
1
1
2
2
1
84001 NUT, HEX, #6-32 MACHINE SCREW  
31118 LOCKNUT 3/8 STRAIGHT PIPE THREAD  
83044 WASHER, 1.125"OD X 0.750"ID, FLA  
31071 FITTING, 1/2 HOSE ID X 3/8" MPT  
31021 BUSHING, 3/4-16 X 1/4 NPSM, HEX HEAD  
31152 VALVE, COMPR 3/8 TUBE OD X 1/4 MPT  
13055 TUBE, VALVE DRAIN , 3/8" OD X .035"TH X 1.5" LG  
31128 FITTING, 90 ELBOW, 3/8 HOSE ID X 1/4 MPT  
31027 FITTING, COMPR 90 MALE ELBOW, 3/8 TUBE OD X 1/4 MPT  
13072 OUTLET, INSIDE TANK HOT WATER  
03297 SINK, HEAT FOR 40A TRIAC  
59008 TRIAC 40A, 600V  
84007 NUT, 3/4-16 HEX JAM  
16  
Figure 3 – CBS-2032e / CBS-2032s Main Assembly  
DWG 101196-D  
ITEM #  
QTY  
PART # DESCRIPTION  
1
1
001050 WELDMENT, CBS-2032e  
2
3
1
1
1
2
2
1
1
1
2
1
1
1
1
2
1
104027 ASSEMBLY, TANK CBS-2032e (SEE FIG. 4)  
22041 INSULATION TANK FRONT CBS-2032e  
22042 INSULATION TANK BACK CBS-2032e  
102080 ASSEMBLY, SMALL SPRAY HEAD, 120V (SEE FIG 5)  
102158 ASSEMBLY, SMALL SPRAY HEAD, 220V (SEE FIG 5)  
102189 ASSEMBLY, POWER BRACKET, CBS-2000e  
52026 CIRCUIT BREAKER, 5A  
4
5
EXPORT  
220V ONLY  
5
6
6
6
58054 SWITCH, PUSH BUTTON  
7
86032 BUSHING, SNAP, 1" MOUNTING HOLE DIA  
52050 TERMINAL BLOCK  
8
9
65002 CONNECTOR, COPPER LUG  
10  
11  
12  
13  
402023 HARNESS, LOW AMP, ELECTRICAL, CBS-2032e, TWO HEATERS  
402032 HARNESS, HIGH AMP, TWO HEATER WIRE SET CBS-2032e  
29021 SPACER, #8 SCREW SIZE  
102192 ASSEMBLY, HOT WATER VALVE, 120VAC  
17  
13  
13  
57047 VALVE, DSV-11, 120 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)  
102193 ASSEMBLY, HOT WATER VALVE, 220VAC  
EXPORT  
220V ONLY  
EXPORT  
1
13  
13  
14  
15  
16  
17  
17  
18  
19  
20  
20  
21  
22  
23  
24  
25  
26  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
57  
57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)  
57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)  
83051 WASHER, #8 SCREW SIZE, FLAT  
220V ONLY  
2
7
17  
1
1
4
3
1
1
4
1
1
1
3
1
1
1
1
1
4
1
1
1
1
2
2
1
1
1
1
1
4
2
5
1
1
2
1
1
1
1
10  
1
1
1
2
83026 WASHER, INTERNAL TOOTH LOCK, #8 SCREW SIZE,  
84002 NUT, HEX, #8-32 MACHINE SCREW  
108002 SWITCHING/CONTROL BOARD, 8 KEYS, D2P (CBS-2032e ONLY)  
108038 SWITCHING/CONTROL BOARD, 8 KEYS, D2P (CBS-2032s ONLY)  
15007 STANDOFF, MALE-FEMALE, THREADED HEX 4-40-1/2"  
29007 NUT, #4-40 KNURLED THUMB  
51042 BOARD, POWER SUPPLY-120VAC  
EXPORT  
220V ONLY  
51055 BOARD, POWER SUPPLY-220VAC  
29019 SPACER, .25" HEX x 1" LG., FEM, #4-40 THREAD  
002065 WELDMENT, HOT WATER FAUCET  
33007 LOCKNUT, 7/16 STRAIGHT PIPE THREAD  
45078 OVERLAY CBS-2032e  
73029 LEG, THERMOPLASTIC, 2.50"(63mm)  
57006 FILL VALVE, S-53 120VAC  
EXPORT  
220V ONLY  
57017 FILL VALVE, S-53 220VAC  
24012 GASKET, S-53 FILL VALVE  
31078 FITTING, S-53 FILL VALVE INLET  
03074 BRACKET, S-53  
82020 SCREW, S-53 FILL VALVE  
31031 FITTING, 90 MALE ELBOW, 3/8 TUBE OD X 3/8 MPT  
86040 CONNECTOR, CABLE CLAMP, 3/4"  
102190 ASSEMBLY, DIGITAL TEMP. PROBE, 5.0" LG.  
102139 ASSEMBLY, WATER LEVEL PROBE, CBS-2030'S  
102195 ASSEMBLY, BUMPER, 2030e  
25056 TUBE, 3/4"OD X 1/2"ID X 4"LG, BREW  
25064 TUBE, 5/8"OD X 3/8"ID X 6.5"LG. HOT WATER  
25055 TUBE, 5/8"OD X 3/8"ID X 12"LG DRAIN  
25057 TUBE, 5/8"OD X 3/8"ID X 14 1/2"LG, COLD WATER  
25058 TUBE 5/8"OD X 3/8"ID X 2.5"LG, HOT WATER FAUCET  
25059 TUBE, 5/16"OD X 3/16"ID X 9 1/4"LG VENT  
86038 CLAMP, HOSE, .670"-.780" DIA RANGE  
86020 CLAMP, HOSE, .875"-.750" DIA RANGE  
86007 CLAMP, HOSE, .593"-.656" DIA RANGE  
25102 TUBE, 1/4"OD X 1/8"ID X 20" LG VENT HOT WATER VALVE  
44004 LABEL GROUND  
44024 LABEL, WARNING-HIGH VOLTAGE  
01479 COVER, TOP CBS-2032 & 42  
01463 COVER, UPPER BASE CBS-2032e  
401219 WIRING DIAGRAM, CBS-2032e, 1PH, 3 WIRE + GR, 2 HEATERS  
102191 ASSEMBLY, RIGHT COVER CBS-2030's  
82053 SCREW, # 6-32 X 1/2" TRUSS HD PH  
46027 LABEL, SPRAY HOUSING  
46029 LABEL, POWER SWITCH  
41016 LABEL, EXTRACTOR  
101171 BREW BASKET ASSY., 13 X 5, DIA HOLE 0.218" (SEE FIG 6)  
ADDITIONAL PARTS FOR CBS-2032s, NOT SHOWN ON DRAWING  
2
101160 ASSEMBLY, BREW BASKET LOCK. 120 VAC  
EXPORT  
220V ONLY  
2
101174 ASSEMBLY, BREW BASKET LOCK. 220 VAC  
2
1
102207 ASSEMBLY, REED SWITCH  
57043 VALVE, BYPASS RIGHT 120 VAC  
57047 VALVE, DSV-11, 120 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)  
EXPORT  
220V ONLY  
1
57076 VALVE, BYPASS RIGHT 220 VAC  
18  
EXPORT  
220V ONLY  
57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)  
57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)  
83051 WASHER, #8 SCREW SIZE, FLAT  
84030 LOCKNUT, #8-32 SCREW SIZE, HEX THIN NYLON INSERT  
57044 VALVE, BYPASS LEFT 120 VAC  
6
4
1
57047 VALVE, DSV-11, 120 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)  
EXPORT  
220V ONLY  
EXPORT  
1
57077 VALVE, BYPASS LEFT 220 VAC  
57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)  
220V ONLY  
57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)  
101175 BREW BASKET ASSEMBLY, 13 x 5, DIA. HOLE 0.280 (SEE FIG. 7)  
1
19  
Figure 4 – CBS-2032e / CBS-2032s Tank Assembly  
DWG 104027-A  
20  
ITEM #  
QTY  
PART # DESCRIPTION  
1
1
4043 WELDMENT TANK CBS-2032e  
2
2
1
1
1
3
2
2
2
2
2
8
8
2
3
1
1
1
1
3
1
1
2
1
1
1
1
2
107021 HEATER ASSY., 3000W/240VAC  
3
31116 LOCKNUT 1/8 STRAIGHT PIPE THREAD  
83041 WASHER, .812"OD X .412"ID, FLAT  
31005 FITTING, 90 ELBOW, 1/4 HOSE ID X 1/8 MPT  
31117 LOCKNUT 1/4 STRAIGHT PIPE THREAD  
31118 LOCKNUT 3/8 STRAIGHT PIPE THREAD  
83044 WASHER, 1.125"OD X 0.750"ID, FLA  
3332 BRACKET 2, ONE SHOT THERMOSTAT  
3297 SINK, HEAT FOR 40A TRIAC  
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
59008 TRIAC 40A, 600V  
83011 WASHER, #6 SCREW SIZE, INTERNAL  
84001 NUT, HEX, #6-32 MACHINE SCREW  
31071 FITTING, 1/2 HOSE ID X 3/8" MPT  
83042 WASHER, .875"OD X .562"ID, FLAT  
31081 PLUG, HEX HEAD 1/4" MPT  
31036 FITTING COMPR. MALE CONNECTOR 1/4 TUBE OD X 1/4 MPT  
25098 FITTING, COMPRESSION MALE CONNECTOR  
84007 NUT, 3/4-16 HEX JAM  
31021 BUSHING, 3/4-16 X 1/4 NPSM, HEX HEAD  
31027 FITTING, COMPR 90 MALE ELBOW, 3/8 TUBE OD X 1/4 MPT  
13072 OUTLET, INSIDE TANK HOT WATER  
31128 FITTING, 90 ELBOW, 3/8 HOSE ID X 1/4 MPT  
31152 VALVE, COMPR 3/8 TUBE OD X 1/4 MPT  
13055 TUBE, VALVE DRAIN , 3/8" OD X .035"TH X 1.5" LG  
24002 O-RING, TANK COVER  
102013 ASSEMBLY, TANK COVER  
53064 THERMOSTAT, SINGLE SHOT,TRIAC  
21  
Figure 5 – Spray Housing Assembly, 120 VAC, Part # 102080  
Spray Housing Assembly, 220 VAC, Part # 102158 (EXPORT ONLY)  
ITEM #  
QTY  
4
PART # DESCRIPTION  
1
2
82112 #8 X 3/4'' PAN HD. PHIL. T.S. 18-8 S.S. SCREW  
57047 VALVE ASSY., DSV-11, 120 VAC  
1
EXPORT  
220V ONLY  
2
3
4
5
6
1
1
1
1
1
57071 VALVE ASSY., DSV-11, 240 VAC  
57073 VALVE REBUILD KIT, DSV11  
102082 SPRAY HOUSING ASSY.  
24054 O-RING 4.237” I.D., #156  
102081 SPRAY PLATE ASSY., 4 7/8" DIA.  
22  
NOTE: The round and square brew baskets pictured below are not interchangeable. Use only the  
type of brew basket that originally came with the brewer.  
Figure 6 – Brew Basket Assembly, 13” X 5”, Part # 101171 (ROUND)  
ITEM QTY PART # DESCRIPTION  
1
2
3
4
1
2
1
1
9021 WIRE INSERT, 13 X 5  
82118 HANDLE SCREW  
23074 BREW BASKET HANDLE, BLACK  
46011 WARNING LABEL  
F002 PAPER FILTERS, 13” X 5”  
500 PER CASE  
NOT  
SHOWN  
COLOR BREW BASKET HANDLES  
PART # DESCRIPTION  
23169 BREW BASKET HANDLE, RED  
23171 BREW BASKET HANDLE, GREEN  
Figure 7 – Brew Basket Assembly, 13” X 5”, Part # 101175 (SQUARE)  
ITEM QTY PART # DESCRIPTION  
1
2
3
5
8
09022 WIRE INSERT, 13” X 5  
23117 BREW BASKET HANDLE, BLACK  
46011 WARNING LABEL  
82096 HANDLE SCREW  
1
1
1
1
57082 MAGNET  
PAPER FILTERS, 13” X 5”  
F002  
NOT  
SHOWN  
500 PER CASE  
COLOR BREW BASKET HANDLES  
PART # DESCRIPTION  
23106 BREW BASKET HANDLE, GREEN  
23107 BREW BASKET HANDLE, ORANGE  
23148 BREW BASKET HANDLE, RED  
23  

Magic Chef MCECM1NB User Manual
LG Electronics UX245 User Manual
Krups Coffeemaker XP2010 User Manual
JVC KD G537 User Manual
Intel Oem 180gb 530 M2 SSDSCKGW180A401 User Manual
HP Hewlett Packard serviceguard t2808 90006 User Manual
Gigabyte GZ FSCA1 SN User Manual
Fujitsu Computer Drive MBA3073 User Manual
FieldServer Telnet FS 8704 11 User Manual
Belkin RK2001ek User Manual