Black Box Computer Accessories KVT16CATUV User Manual

®
®
KVT8CATUV  
KVT16CATUV  
KVT1IP8CATUV  
KVT1IP16CATUV  
KVT4IP16CATUV  
NETWORK SERVICES  
KVM Modules for ServView Rack Tray  
High specification KVM switches that interface  
precisely with the Black Box ServView Rack Tray  
series.  
Sophisticated KVM switching that use Server Access Module technology to simplify cabling and  
avoid occupying a further rack slot  
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)  
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746  
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018  
Customer  
Support  
Information  
FCC and IC RFI Statements  
Federal Communications Commission and Industry Canada Radio Frequency Interference  
Statements  
This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used  
properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has  
been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart  
B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is  
operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which  
case the user at his own expense will be required to take whatever measures may be necessary to correct  
the interference.  
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to oper-  
ate the equipment.  
This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio  
Interference Regulation of Industry Canada.  
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de  
la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada.  
724-746-5500 | blackbox.com  
Page 3  
ServView KVM Module  
Instrucciones de Seguridad  
(Normas Oficiales Mexicanas Electrical Safety Statement)  
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.  
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.  
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.  
4. Todas las instrucciones de operación y uso deben ser seguidas.  
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca  
de una alberca, etc..  
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.  
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.  
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación.  
Todo otro servicio deberá ser referido a personal de servicio calificado.  
9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico  
sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes  
que impidan el flujo de aire por los orificios de ventilación.  
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros  
aparatos (incluyendo amplificadores) que producen calor.  
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como  
se indique en el aparato.  
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.  
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados  
sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.  
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.  
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.  
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.  
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.  
18. Servicio por personal calificado deberá ser provisto cuando:  
A: El cable de poder o el contacto ha sido dañado; u  
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o  
C: El aparato ha sido expuesto a la lluvia; o  
D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o  
E: El aparato ha sido tirado o su cubierta ha sido dañada.  
724-746-5500 | blackbox.com  
Page 4  
Table of Contents  
Contents  
1. Power Adapter Specifications..................................................................................................................................................... 6  
2. Introduction ............................................................................................................................................................................... 7  
2.1 What‘s Included................................................................................................................................................................ 8  
2.2 Additional Items You May Need ....................................................................................................................................... 8  
3. Installation................................................................................................................................................................................ 10  
3.1 Mounting........................................................................................................................................................................ 10  
3.2 Connections ....................................................................................................................................................................11  
3.2.1 EXTernal link (Network or Remote User) .............................................................................................................11  
3.2.2 Server Access Module Links ...............................................................................................................................12  
3.2.3 Power Connection ..............................................................................................................................................13  
4. Configuration........................................................................................................................................................................... 14  
4.1 Initial Configuration ........................................................................................................................................................ 14  
5. Operation..................................................................................................................................................................................15  
5.1 Selecting Server Channels With Rack Tray Buttons ..........................................................................................................15  
Appendix A. Safety Information................................................................................................................................................... 16  
724-746-5500 | blackbox.com  
Page 5  
ServView KVM Module  
1. Power Adapter Specifications  
Power:  
Input:  
DC jack (power adapter included)  
100–240 VAC, 50/60 Hz  
12VDC, 60W  
Output:  
724-746-5500 | blackbox.com  
Page 6  
Chapter 2: Overview  
2. Introduction  
Thank you for choosing this KVM module which provides full function 8 or 16 port KVM switching without occupying a further  
rack slot. The module is designed to fit at the rear of the Black Box ServView Rack Tray so that all circuitry is concealed behind the  
slide out screen and keyboard.  
Thanks to the use of Black Box Server Access Modules (SAMs) the rear connection panel of the KVM module is neat and unclut-  
tered. See Figure 2-1.  
Config switches  
Reserved for future use  
- ensure that both are in  
the up (off) position.  
Options port  
Used for firmware  
upgrades.  
Computer Connection ports  
8 or 16 (depending on model) ports to  
which CAT 5, 5e or 6 link cables are  
used to connect Server Access Modules  
(SAM) which provide the connections  
to each server.  
16  
15  
14  
13  
8
7
6
5
OPTIONS  
12V  
5A  
EXT  
INDOOR  
USE ONLY  
1
2
ON  
12  
11 10  
COMPUTER CONNECTIONS  
9
4
3
COMPUTER CONNECTIONS  
2
1
Power  
input  
socket  
Reserved  
Network or remote extender port  
Function is determined by the  
model of KVM module.  
The green indicator is on when  
power is applied.  
The amber indicator is reserved for  
future use.  
Figure 2-1. The rear panel of the KVM module.  
724-746-5500 | blackbox.com  
Page 7  
ServView KVM Module  
2.1 What‘s Included  
Your package should include the following items. If anything is missing or damaged, contact Black Box at 724-746-5500  
• KVM module  
• Power adapter and power cord  
CD-ROM containing this user manual in PDF format  
• Safety leaflet - Please carefully read this leaflet.  
2.2 Additional Items You May Need  
• Upgrade (serial null modem) cable (6.5 feet) (P/N: EYN257T-XXXX-FF)  
724-746-5500 | blackbox.com  
Page 8  
Chapter 2: Overview  
724-746-5500 | blackbox.com  
Page 9  
ServView KVM Module  
3. Installation  
3.1 Mounting  
The KVM module is designed to interlock precisely with the rear of the ServView rack tray.  
1 If the ServView rack tray is already fitted, either remove it or carefully gain access to the rear of the rack mount unit.  
2 Locate the connection plate at the rear of the rack tray and orientate the KVM module so that its universal Centronics® 36-pin  
connector aligns with the socket on the connection plate. See Figure 3-1.  
KVM module  
Locating pins  
Universal Centronics®  
36-pin connector  
Rack tray connection plate  
(as viewed from the pull out  
keyboard - side rails not  
shown for clarity).  
Locking screw  
Figure 3-1. Aligning the KVM module with the connection plate of the rack tray.  
3 Carefully slide the KVM module in so that its connector and two locating holes mate correctly with the corresponding connec-  
tor and locating pins on the connection plate.  
4 Tighten the locking screw until it is finger tight.  
724-746-5500 | blackbox.com  
Page 10  
Chapter 3: Installation  
3.2 Connections  
Connections to the rack tray video display, keyboard and trackpad are all handled by the single link that is made when the KVM  
module is attached to the tray. Therefore, all server, network and power connections are located at the rear of the unit.  
3.2.1 EXTernal link (Network or Remote User)  
The single RJ-45 socket labeled as EXT is used to allow either global or remote users to login and control connected servers. The  
EXT port provides one of the following links (dependant on the model of KVM module):  
• An ethernet network link, labeled  
,
or  
KVM  
only  
• A remote extender link (to attach a ServSwitch CX R or CX R USB), labeled  
. Note: This port is NOT a network port.  
1 Wherever possible, ensure that power is disconnected from the KVM module.  
2 Connect a CAT 5, 5e or 6 link cable to the port labeled EXT. See Figure 3-2.  
EX  
T
Link cable from either a network  
connection or a remote extender  
Figure 3-2. Connect a CAT 5, 5e or 6 link cable to the EXT port.  
3 Connect the other end of the cable as follows:  
• If the EXT port label shows  
• If the EXT port label shows  
connect the link cable to a network switch/router.  
KVM  
only  
connect the link cable to a ServSwitch CX R or CX R USB.  
724-746-5500 | blackbox.com  
Page 11  
ServView KVM Module  
3.2.2 Server Access Module Links  
Dependant on the KVM module used, there will be either 8 or 16 RJ-45 sockets labeled as COMPUTER CONNECTIONS. Each  
socket supports a CAT 5, 5e or 6 link to an individual server system.  
Note: The maximum length of the cable can be up to 10 metres (32 feet), however, for KVM modules KVT8CATUV and  
KVT16CATUV ensure that the overall distance between a remote user (connected to a remote extender) and any server must not  
exceed 300 metres (980 feet).  
1 Wherever possible, ensure that power is disconnected from the KVM module.  
2 Connect a CAT 5, 5e or 6 link cable to one of the COMPUTER CONNECTIONS ports. See Figure 3-3.  
8
7
6
5
4
COMPUTE
3
2
1
Link cable to a Server Access Module  
Figure 3-3. Connect a CAT 5, 5e or6 link cable to a COMPUTER CONNECTIONS port.  
3 Connect the other end of the cable to the Server Access Module (SAM) that is linked to the required server system. For more  
information about connecting SAMs, please refer to the appropriate ServSwitch user guide as appropriate to the KVM module  
being used:  
• KVT8CATUV or KVT16CATUV  
• KVT1IP8CATUV or KVT1IP16CATUV ---> use KV1081A/KV1161A (ServSwitch CX Uno IP) user guide,  
• KVT4IP16CATUV ---> use KV4161A (ServSwitch CX Quad IP) user guide.  
4 Repeat steps 2 and 3 for each server system.  
---> use KV0081A/KV0161A (ServSwitch CX Uno) user guide,  
724-746-5500 | blackbox.com  
Page 12  
Chapter 3: Installation  
3.2.3 Power Connection  
The KVM module is provided with a power adapter capable of supplying the display monitor, keyboard and KVM module.  
IMPORTANT: You must only use the manufacturer approved power adapter with the KVM module.  
IMPORTANT: Due to the length of the power cable, if the rack tray is mounted high in the rack it may not be possible to place the  
power adapter at floor level. In this case it is important to mount it securely and in such a manner that it is not suspended from its  
output cable.  
1 Attach the output lead from the power adapter to the 12V socket on the rear panel of the KVM module. See Figure 3-4.  
12V  
5A  
1
2
O
N
Figure 3-4. Connect the power adapter to the rear panel power socket.  
2 Connect the IEC connector of the supplied country-specific power lead to the socket of the power adapter.  
3 Connect the power cord to a nearby power outlet.  
Note: Both the KVM module and the power adapter generate heat when in operation and will become warm to the touch. Do  
not enclose them or place them in locations where air cannot circulate to cool the equipment. Do not operate the equipment  
in ambient temperatures exceeding 35oC. Do not place the products in contact with equipment whose surface temperature  
exceeds 35oC.  
3.2.3.1 Disconnecting Power  
When removing the power connection be aware that the plug has a locking mechanism to prevent accidental disconnects. To  
remove, pull back the flat top segment of the plug body to disengage the lock and gently pull the whole plug from the power  
socket. See Figure 3-5.  
Figure 3-5. Disconnecting the power adapter.  
724-746-5500 | blackbox.com  
Page 13  
ServView KVM Module  
4. Configuration  
4.1 Initial Configuration  
The precise details for configuration of the KVM module will depend on the model being used. For more information, please refer  
to the Configuration section of the appropriate ServSwitch user guide as appropriate to the KVM module being used:  
• KVT8CATUV or KVT16CATUV  
---> use KV0081A/KV0161A (ServSwitch CX Uno) user guide,  
• KVT1IP8CATUV or KVT1IP16CATUV ---> use KV1081A/KV1161A (ServSwitch CX Uno IP) user guide,  
• KVT4IP16CATUV  
---> use KV4161A (ServSwitch CX Quad IP) user guide.  
724-746-5500 | blackbox.com  
Page 14  
Chapter 5: Operation  
5. Operation  
In operation, you can select server channels in a number of ways, including:  
• On screen menu,  
• Keyboard hotkeys,  
• Control buttons on the ServView rack tray (see below).  
For more information about the on screen menu and keyboard hotkey methods, please refer to the Operation section of the  
appropriate ServSwitch user guide as appropriate to the KVM module being used:  
• KVT8CATUV or KVT16CATUV  
• KVT1IP8CATUV or KVT1IP16CATUV ---> use KV1081A/KV1161A (ServSwitch CX Uno IP) user guide,  
• KVT4IP16CATUV ---> use KV4161A (ServSwitch CX Quad IP) user guide.  
---> use KV0081A/KV0161A (ServSwitch CX Uno) user guide,  
Note: On screen menus will show the ServView name, not the ServSwitch CX name shown in the CX series user guides.  
5.1 Selecting Server Channels With Rack Tray Buttons  
With the rack tray keyboard exposed, you will see a control panel in the top right corner. See Figure 5-1.  
1
2
3
4
5
6
7
8
G
A
B
C
D
E
F
H
Figure 5-1. Control panel.  
To select channels:  
• Channels 1 to 8 - Press and release the appropriate channel button. The channel will be switched and the indicator above the  
pressed button will illuminate.  
• Channels 9 to 16 - Press and hold the appropriate channel button (e.g. button 1 for channel 9, button 4 for channel 12, etc)  
for 2 to 3 seconds. The channel will be switched and the indicator above the pressed button will flash.  
To display the on-screen menu:  
• Press any two buttons simultaneously.  
724-746-5500 | blackbox.com  
Page 15  
ServView KVM Module  
Appendix A. Safety Information  
• You must only use the manufacturer approved power adapter with the KVM module.  
• For use in dry, oil free indoor environments only.  
• The module and its power supply generate heat when in operation and will become warm to the touch. Do not enclose them  
or place them locations where air cannot circulate to cool the equipment. Do not operate the equipment in ambient tempera-  
tures exceeding 35 degrees Centigrade. Do not place the products in contact with equipment whose surface temperature  
exceeds 35 degrees Centigrade.  
• Warning - live parts contained within power adapter.  
• No user serviceable parts within power adapter - do not dismantle.  
Plug the power adapter into a socket outlet close to the module that it is powering.  
Replace the power adapter with a manufacturer approved type only.  
Do not use the power adapter if the power adapter case becomes damaged, cracked or broken or if you suspect that it is not  
operating properly.  
If you use a power extension cord with a unit, make sure the total ampere rating of the devices plugged into the extension  
cord does not exceed the cord’s ampere rating. Also, make sure that the total ampere rating of all the devices plugged into the  
wall outlet does not exceed the wall outlet’s ampere rating.  
Do not attempt to service the units yourself.  
Please also carefully read the separate safety leaflet packed with this product.  
724-746-5500 | blackbox.com  
Page 16  
Appendices  
724-746-5500 | blackbox.com  
Page 17  
Black Box Tech Support: FREE! Live. 24/7.  
Tech support the  
way it should be.  
Great tech support is just 30 seconds away at 724-746-5500 or blackbox.com.  
®
®
NETWORK SERVICES  
About Black Box  
Black Box Network Services is your source for more than 118,000 networking and infrastructure products. You’ll find everything  
from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by  
free, live 24/7 Tech support available in 30 seconds or less.  
© Copyright 2010. Black Box Corporation. All rights reserved.  
KVT8CATUV series, rev. 1  
724-746-5500 | blackbox.com  

Magnavox AZ 2805 User Manual
LG Electronics TU500F User Manual
LG Electronics KG190 User Manual
JVC RV B90 User Manual
ID Tech 60 User Manual
Fujitsu Computer Drive MHV2040BH User Manual
Fetco Home Decor Coffeemaker CBS 2052E User Manual
Brother MFC 5840CN User Manual
Black & Decker HOME CAFE GT320 User Manual
Belkin F4D247 User Manual