Rockford Fosgate RP9314 User Manual

t h e c o n n e c t i n g  
AEROPORT  
RP9314 / RP9316 / RP9317  
INSTALLATION & OPERATION MANUAL  
®
®
TABL E O F C O N T E N T S  
Aeroport Contents .................................................................................... 1  
Introduction ............................................................................................. 1  
Operating Features ................................................................................... 1  
Calculating Port Length ............................................................................ 2  
Installation Considerations ....................................................................... 3  
Mounting The Aeroport ............................................................................ 3  
Warranty Information ............................................................................... 4  
AERO P O RT CO N TEN TS  
RP9314  
RP9317  
One tube 16" long  
Two Aeroport end flanges  
One tube 16" long  
Two Aeroport end flanges  
(no tube, use standard 6" PVC pipe)  
RP9316  
One tube 16" long  
Two Aeroport end flanges  
IN T RO D U C T I O N  
This manual provides information on the features, installation and  
operation of the Aeroport. We recommend you keep this manual for  
future reference.  
We strongly recommend you have your Authorized Rockford Fosgate  
Dealer install your new Aeroport; however, if you choose to do the  
installation yourself, please be sure to read the entire manual before  
beginning. When installing this product, please use the proper safety  
precautions while using power tools or flammable materials.  
O P ERAT I N G / FEAT U RES  
A major design challenge when building a vented speaker enclosure is the  
turbulence generated by the air moving through the port. The air move-  
ment causes harmonic distortion as well as a whistling noise from the port.  
The Aeroport was designed to reduce this effect. Inspired by the bell on a  
brass instrument, the flanges on the ends of the Aeroport reduce the air  
friction and distortion inherent in the operation of a conventional tube.  
Fifth harmonics distortion  
0.20%  
0.15%  
0.10%  
0.05%  
Standard T  
ube  
50 watt  
20 watt  
10 watt  
Aeroport  
5 watt  
2 watt  
1
The Harmonics graph illustrates the advantage of using the Aeroport over  
a conventional tube. The human ear can sense .1% distortion. A standard  
tube can reach that amount with only 10 watts of input where as the  
Aeroport reaches only .05% distortion with 50 Watts of input. The end  
result? You can apply more input power with less distortion or use a  
smaller diameter Aeroport in place of a standard tube.  
If using a computer aided speaker design program such as Term-Pro, port  
velocities of up to 15% can be alleviated.  
C ALC U LAT I N G P O RT LEN G T H  
After the enclosure has been designed, the following formula may be  
useful when calculating the port length:  
RP9314  
RP9316  
2
8466.4R  
Lv =  
–1.463R  
Radius  
2
Radius  
(Vb)Fb  
>
>
Lv = port length in inches  
Vb = volume of box in cubic feet  
Fb = tuning frequency  
R=1.34  
R=2.03  
R = radius of port  
When cutting the Aeroport center tube, the length should be cut 3"  
shorter than calculated. When the end flanges are affixed, each end  
extends the tube one and a half inches. If the determined port length is 10"  
then the fully assembled Aeroport (center tube with flanges attached)  
should measure 11" (the extra 1/2" on each end contributes to harmonics  
and not the length of the tube).  
11" Overall Length  
10"  
7" Cut Length  
Standard Tube  
Aeroport Tube  
2
IN STALLAT I O N C O N SI D ERAT I O N S  
Before cutting any holes in the enclosure first determine the placement of  
the Aeroport. Best results will be derived by placing the woofer and port  
on the same side of the enclosure. To maintain proper tuning and noise  
free operation, the Aeroport should be positioned to allow the flange at  
least one port diameter clearance from the back and side walls. For  
instance, if you were using a 4" diameter port, keep it 4" from the bottom  
of the enclosure and 4" from the enclosure walls.  
4" Dia. Port  
4" Minimum  
M O U N T I N G TH E AERO P O RT  
When gluing the end flanges to the main tube, use a good, quick drying  
epoxycement. Carefullyapplya 1/2"bead on the end ofthe portthen twist  
the end piece on until seated properly.  
To flush mount the 3" Aeroport, cut out a 4-5/16"  
diameter hole and a 5-9/16" diameter hole for  
the 4" Aeroport and cut a 9" diameter hole of the  
6" Aeroport. After the holes have been cut, use a  
1/2" roundover router bit to accommodate the  
curve needed for the end flange.  
When mounting the Aeroport to the enclosure,  
apply the quick drying epoxy cement to the  
mounting surface and use silicone caulk or fiber-  
glass compound on the inside of the enclosure to  
secure the port to the wood.  
Roundover Bit  
3
W ARRAN TY IN FO RM ATI O N  
The Aeroport is nearly indestructible and will provide years of service if  
installed and used in accordance with the instructions in this manual. If  
this product should prove to be defective due to a manufacturing defect  
within a period of ninety (90) days from the date of purchase, contact your  
Authorized Rockford Fosgate Dealer or Rockford Corporation Customer  
Service Department at 1-800-669-9899 for replacement instructions.  
4
Rockford Fosgate  
Rockford Corporation  
546 South Rockford Drive  
Tempe, Arizona 85281 U.S.A.  
In U.S.A., (602) 967-3565  
In Europe, Fax (49) 4207-801250  
In Japan, Fax (81) 559-79-1265  
8/96  

Tiffen Magnum X3T User Manual
Sylvania NB531SLX User Manual00000000#
Sunbeam PB7600 User Manual
Star Manufacturing Peristaltic Heated Condiment Dispenser S257 User Manual
Sony Xplod XVM R70 User Manual
Sony SOLID STATE MEMORY PMW 100 User Manual
Sennheiser 504302 User Manual
Sanyo HF D4U User Manual
Sanyo FXCD 1350 User Manual
Samsung SBH600 User Manual